38
Company Overview Excellence in Providing Custom Solutions & Achievement of Customer Satisfaction

Intelli power presentación corporativa 2013

Embed Size (px)

Citation preview

Page 1: Intelli power presentación corporativa 2013

Company Overview

Excellence in Providing Custom Solutions &

Achievement of Customer Satisfaction

Page 2: Intelli power presentación corporativa 2013

IntelliPower Early History

•  Founded in 1988 in California – Privately held

•  First Single Phase UPS designed with the Intelligent Digital Control

•  Influenced the company name - IntelliPower, Inc. for intelligent power

•  Power Conversion Products - Double Conversion On Line Topology

•  Started building private label On Line UPS for OEMs such as Deltec Corp.

•  Early Military Applications - Rugged, Global Input & custom variations for: •  F-22 Fighter ground support > 14 Years

•  Predator UAV ground support > 12 Years •  US Coast Guard > 18 Years

•  Added military systems for Ft. Gordon & other bases

2

Page 3: Intelli power presentación corporativa 2013

MILITARY & FEDERAL GOVT •  Deployable Communications/Deployable Power

•  UAV Programs •  Navy Shipboard – Carriers, Destroyers, & Submarines

•  C4 ISR •  Missile Defense

INDUSTRIAL •  Severe Environmental Requirements

•  Oil and Gas Exploration •  Satellite Communications Systems

•  Industrial Controls •  Alternative Energy

•  Transportation - Traffic Signals, Toll Roads, etc. COMMERCIAL - Mission Critical

•  Data Center/Server Rooms •  Communications Systems

•  Medical Measurement Instruments •  Global & Mission Critical Applications

3

Market Segments/Strategic Focus

Page 4: Intelli power presentación corporativa 2013

Typical Environments & Functional Requirements

Environmental Requirements •  Extreme High and Low Temperatures (-40c to

+70c) •  Mil-Std’s- 461, 810f, 901D, 464, 1399, 1275D,

167 •  High Shock & Vibration •  Dust and Dirt Environments •  Outdoor Applications- Rain, Snow and Blowing

Sand/Dirt •  Poor Power Quality from Generators or Power

Source

Functional Requirements •  Sealed Weatherproof UPS •  Galvanic Isolation •  Global AC Inputs/Outputs •  Multiple Voltages and Frequencies •  Single and 3-Phase Inputs •  DC Voltage Inputs/Outputs •  Extended Battery Runtimes •  Lithium Iron Phosphate Batteries

4

Page 5: Intelli power presentación corporativa 2013

Products

•  UPS •  AC & DC Inputs and Outputs

•  Power Conditioners •  Inverters

•  12VDC-270VDC Input •  110, 115, 120, 220, 230 and 240VAC Output

•  Frequency Converters •  45Hz-450Hz

•  Power Converters •  AC-DC/DC-AC

•  PDU’s •  Internal and External

•  Transit Case Based Systems

5

Page 6: Intelli power presentación corporativa 2013

•  Double Conversion On Line, uProcessor & DSP Based Technology

•  Internally Developed Technology - Can support any features needed

•  Flexible structure, common boards, & programmable product mix

•  Full range of functionality - ratings of 300VA to 6000VA

•  Global AC Input, DC Input, AC & DC Output, Freq. Conv., Isolation

•  Customized Configurations/Functions to meet exact customer requirements including controls, PDUs & communications features

•  Optional Enclosures & special packaging to meet size & weight, as well as functionality for any requirements

Bright-UPS Characteristics

6

Page 7: Intelli power presentación corporativa 2013

IntelliPower Power Solution Benefits

7

•  Provides Peace of Mind Offering Optimum Solutions

•  Internally Developed Advanced Technology (22 years)

•  Not repackaged commercial UPS made in China

•  Intelligent/Bright UPS digital controlled power conversion

•  Unmatched flexibility to provide configurable solutions

•  Proven Reliability with 22+ years in the field

•  Track Record of customer satisfaction & loyalty

•  Consistent Responsive Quality Service & Support

•  Totally Made In USA – ISO 9001:2008 Certified

Page 8: Intelli power presentación corporativa 2013

8

IntelliPower Configuration Worksheet & Website Configuration Form

Page 9: Intelli power presentación corporativa 2013

9

Why IntelliPower vs. Others

IntelliPower • UPS circuitry & firmware designed fully by IntelliPower for over 23 years • For Military use & Industrial applications • Full control over all circuit design & embedded firmware technology in UPS • Can support any user customized requirements & support MIL-STDs via design

Others • Are using Commercial UPS boards not designed for military and Industrial use • Are repackaging commercial boards in rugged enclosure • Do not have access to technology of UPS boards made by other companies, UPS boards usually designed & made in China • No ability to modify circuitry or embedded firmware in UPS to meet many customer requirements

Page 10: Intelli power presentación corporativa 2013

10

Typical Military Products

Page 11: Intelli power presentación corporativa 2013

Military Customers

•  All Branches of DoD, GD C4S, GD-AIS, GD Satcom, Rockwell Collins, Northrop Grumman, Lockheed Martin, SAIC, Telecom Systems, DRS, Raytheon, Dell Federal, L-3, Cubic, BAE, GTSI, ARINC, Boeing, ND Satcom, Marshall Com, Textron AAI, Segovia Systems, ITT , UK Royal Navy, German Navy, Dutch Navy, Italian Navy, Japanese Navy and Singapore Navy

•  April 2010 received Industry Partner Award for Excellence from Army & General Dynamics

11

Page 12: Intelli power presentación corporativa 2013

12

Army and Marine Programs

LMCO – Owego Power Converter/Conditioner •  LAV 2 Amphibious Military Vehicle for Marines •  24VDC Input & 120VAC, 60Hz Output •  MIL-STDs 1275D for military vehicles

LMCO - Virginia - Power & Frequency Converter •  For Army Ft Eustis & Others •  2000VA, 1500W Rack Mount •  Global 120/230VAC, 50/60Hz Input •  120VAC, 60Hz Output •  No battery

Page 13: Intelli power presentación corporativa 2013

Army and Marine Programs

13

SWAN and WPPL Program for Army and Marines •  Global AutoSelect 120/240 VAC Input UPS •  3000VA, 2100W Power Rating •  Internal Hot Swap Battery Drawer •  6 Inverter Outputs •  2 Isolated Non-Inverter Outputs •  High Temp – 50c •  EBP with two Hot Swap Battery Drawers

Raytheon – Ground Based Operational Surveillance System-(GBOSS) •  1100VA, 740W •  115VAC or 230VAC Input and 120VAC Output •  Hot Swap Battery Drawer •  High Temp – 50c •  2U, Rack 3.5”H x 17”W x 18”D

Page 14: Intelli power presentación corporativa 2013

Army and Marine Corps Programs

14

US Marine Corps Tactical Data Network-Data Distribution System-Modular (TDN-DDS-M) •  Global 120/230VAC, 50/60Hz Input UPS – •  120VAC, 60 Hz Output •  Hot Swap batteries – 15 minute run time for 500W •  Impressive Functionality in Compact (in 1U chassis) •  Digital Technology – On Line Double Conversion •  Isolated with Input Power Factor Correction •  Rugged to meet 810F. Also 461E CE102, FCC Cl A •  SNMP communications feature included •  DDS-M Marines Program - GDC4S •  Contract for Quantity 5000 units (so far) •  After extensive field qualification testing

Page 15: Intelli power presentación corporativa 2013

15

Army and Marine Corps Programs

GDC4S Warfighter Information Network-Tactical (WIN-T) UPS •  3000VA, 2100W Isolated UPS 1 •  20VAC, 45/45Hz Input & 120VAC, 60Hz Output •  High Temp – 20F Rugged 110F •  SNMP Communications •  Hot Swap Battery •  UPS: 3U- 5.25” x 17” W x 20” D •  MIL-STDs

Page 16: Intelli power presentación corporativa 2013

Army and Marine Corps Programs

16

GD SATCOM US Army Truck Mount •  5000VA, 4000W Isolated UPS •  230VAC, 50/60Hz Input & 230VAC, 60Hz Output •  High Temp - 50C Rugged 810F •  SNMP Communications •  External Battery 15 minute for load of 4000W •  UPS: 4U- 23”D EBP: 3U- 23”D •  MIL-STDs

GDC4S ARMY TAC HUB •  3000VA, 2100W, Isolated •  Global 120/230VAC Input – 120VAC, 60Hz Output •  Cold Start, Remote Control, SNMP Communications •  High Temp - 50C Rugged 810F •  3U-22”D Enclosure

Page 17: Intelli power presentación corporativa 2013

17

Navy Projects NGC SYKESVILLE-NEWPORT NEWS UPS SYSTEMS

Common UPS For USS Gerald R. Ford Aircraft Carrier •  3000VA, 2100W Isolated for shipboard •  Alt. A & B 115VAC, 50/60Hz Inputs-AutoSelect •  115VAC, 60Hz Output •  Extreme Temp 60C •  EBP with military batteries rated for 80C •  Short Enclosures 17”D •  UPS 3U & EBP 2U •  SNMP Communications •  Extensive testing protocol - Lab View

Page 18: Intelli power presentación corporativa 2013

18

Navy Programs

LMCO-Fort Worth F35 JSF (UK Royal Navy) •  Power Rating: 2KVA, 1.8KW Isolated Double Conversion On Line •  Input: 220-230VAC, 45-450Hz…………..Output: 230VAC, 60Hz •  Enclosure: 3U-17”D •  MIL STDS: 461E, 1399, 810F

NSWC – SHIPBOARD UPS •  2000VA, 1500W Isolated for Shipboard •  115VAC Input & Output •  High Temp - 50C •  Modular UPS, Battery & Isolation Transformer •  Free Standing Modular Enclosure

Page 19: Intelli power presentación corporativa 2013

19

NGC Charlottesville Navy Shipboard UPS •  3000VA, 2100W Isolated •  Global 115/230VAC, 50/60Hz Input •  115VAC, 60Hz Output •  Hot Swap Battery Drawer •  Navy MIL-STDs

Navy Projects

US Navy NAVAIR (NGC & BAE) •  Fire Scout VTUAV •  2KVA, 1.5KW 2U Rack Enclosure •  120VAC Input/Output •  Isolated - Shipboard Delta Source •  Six Cir Mil output receptacles •  50C Temp Rated & MIL-STDs •  Convertible for land-based racks

Page 20: Intelli power presentación corporativa 2013

Navy Projects

20

Northrop Grumman Sperry Marine Guidance Control UPS for Littoral Combat Ship (LCS) •  IPI Supplied complete wired 901D Rack System (2 Prototypes) •  US Navy has released additional ships to be built

3KVA, 2.1KW Global 120/240VAC Input UPS 120VAC, 60Hz output

•  Hot swap battery drawer in UPS enclosure •  UPS Enclosure: 3U-25”D •  Two more hot swap battery drawers in EBP •  EBP Enclosure: 3U-25”D •  Intelligent Global Isolated Input Maintenance Bypass (IGMB) •  IGMB Enclosure: 3U-15”D •  Cable management arms used •  High Temperature Rugged Design •  All Navy MIL-STDs-461E, 1399, 810F, 901D •  Extensive documentation provided •  Full Program Management by IntelliPower

Page 21: Intelli power presentación corporativa 2013

21 21

Navy Projects

NAVY SEWIP Program (Surface Electronic Warfare Improvement Program) •  3KVA & 6KVA Navy Shipboard UPS’s •  Built in PDU •  10 Computer Controlled Outlets •  400Hz & 60Hz Inputs •  Multi Function Controls •  Battle Short - Remote Controlled •  FULL MIL-STDs Compliant

Shipboard UPS & Multi-Control System Replaceable LRU’s •  5.33KVA, 4KW, On-line Isolated •  115VAC, 60Hz Input UPS •  120VAC, 60Hz Output •  Hot Swap Batteries •  SNMP Ethernet Control

Page 22: Intelli power presentación corporativa 2013

22

Navy Projects

Raytheon Photon Research Navy UPS •  2000VA, 1400W Isolated •  115VAC Input & Output •  15 minute battery run time with 1000W load •  High Temp - 50C •  3U-24”D Enclosure •  Terminal Strip Power Connections

DRS Power & Control Div – DDG-51 Destroyer •  1500VA, 1100W Isolated for Shipboard •  115VAC Input & Output •  2U External Battery Pack + Internal Battery •  Approx 36 minute run time w/load of 950W •  SNMP & Special controls included •  Enclosure: 3U, 5.25”H x 16.89”W x 20”D Alum •  Navy MIL-STDs

Page 23: Intelli power presentación corporativa 2013

23

Navy NSWC Shipboard UPS For LCS •  Sealed UPS to Meet IP 65+ for Rain & Dust •  All Electronics are completely sealed •  Air Flow across top - front to rear •  Across externalized flow-through heat sinks •  Sealed from internal electronics •  1100VA, 750W to 3000VA, 2100W Power Ratings •  Input to Output Isolated •  115VAC, 50/60Hz Input •  120VAC, 60Hz Output or •  24VDC Output •  Sealed UPS Module: 2U-23”D •  EBP Battery Module: 2U- 23”D

Navy Projects

Page 24: Intelli power presentación corporativa 2013

24

Italian Navy UPS Systems •  800VA, 560W Isolated •  115VAC Input & Output •  19 minute battery run time for 500W •  High Temp - 50C •  2U-18”D Enclosure •  Battle-short remote control

Navy Programs

Rockwell Collins Germany- Navy •  Extreme Temp-65C •  Global 115/230VAC In-115VAC out •  Isolated for Delta Shipboard •  2U-15” Deep- Very Compact •  Hot Swap Mil type batteries (80C) •  Terminal strip power connections •  RS232 data port •  Relay control features

Page 25: Intelli power presentación corporativa 2013

25

Singapore Navy UPS System •  3KVA, 2.1KW Rating in 3U Enclosure •  230VAC Input & Output, 50/60Hz •  8 Internal Large 12V10.AH Batteries •  UPS: 3U, 5.25”Hx17”Wx26”D •  EBP: 2U, 3.5”Hx17”Wx 24”D •  10 minute run time for 2100W •  Navy MIL STDS •  Environmental Testing by IntelliPower •  Test Report attached

Navy Projects

Page 26: Intelli power presentación corporativa 2013

26

Air Force and Special Forces Deployable UPS •  Global AutoSelect 120/240 VAC Input •  Outputs: Selectable 120, or 115 VAC, 50 or 60Hz •  Galvanic Isolation •  Rugged LCD Control/Display Panel •  4 Inverter Outputs •  2 Isolated Non-Inverter Outputs •  High Temp-50C

US Air Force Programs

Page 27: Intelli power presentación corporativa 2013

Air Force Programs

EC-130 Compass Call Aircraft

•  3-Phase 400Hz Input •  28Vdc output •  3kVA/2.5kW •  LCD Display •  Variable Speed Fans •  Galvanic Isolation •  Power Factor Correction •  Mil Std’s 810f, 464, 461f

27

Page 28: Intelli power presentación corporativa 2013

28

Industrial Applications

Page 29: Intelli power presentación corporativa 2013

29

Industrial Customers

Page 30: Intelli power presentación corporativa 2013

Oil Rig Field Truck Application

30

Ruggedized Global Input UPS •  Rugged Uninterruptible Power System (UPS) •  Hot Swap Batteries •  Compact & Modular •  On Line Double-Conversion Technology •  Isolated with Input PFC •  Global Input Voltage & Frequency •  120VAC & 24VDC Output Voltages •  Military & NEMA Connectors

Page 31: Intelli power presentación corporativa 2013

Oil field Applications

31

Extreme High Temperature UPS •  IntelliPower Bright UPS 1500VA, 1150W •  Input Voltage: 120Vac (-25% to +15%) •  Input Frequency: 50/60Hz •  Galvanic Isolation •  Rated for an operating temp of -65C to +80C •  Output Voltage: 120VAC+/- 2% •  SNMP Ethernet port •  UPS Operating: -22°F to 149°F (-30°C to 65°C)

Page 32: Intelli power presentación corporativa 2013

Toll Road Outside Cabinet Application

32

Toll Roads •  Rating: 1500VA, 1200W •  Input AC Voltage: 120VAC, (-25% to +15%, without needing battery) •  Input Frequency: 50/60Hz (47 to 63Hz) •  PFC Feature: Input Power Factor Correction •  Output Voltage: 120VAC, ±3% •  Output Frequency: 50/60Hz •  Temperature: -10C to +55C Operating

Page 33: Intelli power presentación corporativa 2013

Schlumberger Oilfield AC & DC Output Application

AC & DC UPS System • 500VA, 350W • Input AC Voltage:120VAC • (-25% to +15%, without needing battery) • 50/60Hz (47 to 63Hz) • Input Power Factor Correction • Output Voltage: AC-120VAC, ±3% • DC- 13.5VDC with currents up to 11.8 A.(160W) • Regulation +/- 0.5%, ripple 100mV peak to peak • 50/60Hz, frequency follower • 0C to +50C Operating

33

Page 34: Intelli power presentación corporativa 2013

34

Sandridge High Temp Rugged UPS

Sandridge Land Rig UPS System •  1500VA, 1250W •  Input AC Voltage: 120VAC •  50/60Hz (47 to 63Hz) •  Input Galvanic Isolation •  12 minutes with 1050W load •  Operating Temp -10c – 60C (140F) •  3U, 5.25” D x 17”H x 20” W

Page 35: Intelli power presentación corporativa 2013

Waste Water Treatment

35

City of Aurora-Pump Stations •  1500VA/1050W •  Low Temp operation down to -20c •  Outdoor Cabinet •  Custom Ethernet Communications •  120VAC In/Out 60Hz.

Page 36: Intelli power presentación corporativa 2013

36

NOV High Temp Rugged UPS

NOV Data Logging UPS System •  1100VA, 750W •  Input AC Voltage: 120VAC •  45/450Hz (47 to 63Hz) •  Galvanic Isolation •  Operating Temp -0C – 55C •  3U, 5.25” D x 17”H x 17” W

Page 37: Intelli power presentación corporativa 2013

37

Halliburton High Temp Rugged UPS

Halliburton Oil Field UPS System •  3000VA, 2100W •  Input AC Voltage: 120VAC •  40/650Hz (47 to 63Hz) •  Galvanic Isolation •  6 minutes with 1800W load •  Front Panel Hot Swap Battery •  Operating Temp -10c – 50C •  3U, 5.25” D x 19”H x 20” W

Page 38: Intelli power presentación corporativa 2013

Thank You!

QUALITY POLICY

IntelliPower is committed to customer satisfaction by delivering power system

solutions and services that meet or exceed customer requirements through

design innovation and continuous improvement.

38