fiXtress Schematic Review

Page 2: FiXtress Schematic Review

BQR Profile

Founded in Israel at 1989 as a consulting company in the field of

reliability and maintenance engineering

More then 2,000 projects and over 120 customers

All our software solutions developed based on customers needs and

thousands of successful projects for RAMS &ILS

Today the main business of BQR is to develop and sell software for

the EDA market

2

BQR Confidential Information

Page 3: FiXtress Schematic Review

Partial Customer Base & Industries

3

Industries

• Medical Device• Aerospace &

Defense• Automotive• Railways• Pharmaceutical• Manufacturing• Chemical• Electronics• Oil & Gas• Wind Energy

Page 4: FiXtress Schematic Review

Schematic review today

A process that combines DRC run and checks with a manual review of the schematic

A very labor intensive work with very problematic result due to high human error chances

Complex to implement all required rules to comply to company specs

4

Page 5: FiXtress Schematic Review

When the fiXtress Schematic Review is used

Used directly during and at the end of the design process

Used after a regular DRC is used to prevent duplicated errors.

Before an automated stress analysis is done

5

Page 6: FiXtress Schematic Review

fiXtress solution: automated schematic review

fiXtress component libraries contain a component models that provides better insight

fiXtress Schematic review checks a wide rang of rules to find a deeper level of errors that up until today were mainly manual

Allows for customization and for creation of new rules for company specs

6

Page 7: FiXtress Schematic Review

fiXtress Schematic Review concept

BOM & Netlist imported from different CAD software

Project rules and common rules are chosen to comply to the company and design specs

Run the chosen rules and screen the relevant errors into the report

Rerun as needed

7

Page 8: FiXtress Schematic Review

Core set of fiXtress schematic review common rules

8

Each Group is actually a family of rules that produce error massages according to the cause of the described principle

Page 9: FiXtress Schematic Review

Schematic Review rule selection

9

Chose the relevant rules for your project and company specs

The schematic review checks for rule compliance for the project

Press Copy to project to use selected rules

Page 10: FiXtress Schematic Review

Error check and error report

10

Press the verify button to run the selected checks

Check the relevant errors and add them to the report

Page 11: FiXtress Schematic Review

11

The SDA bus requires pull up resistor per the data sheet.The pull up resistors are set as “LAB” therefore were not populated

Schematic Error Example:connectivity verification

Page 12: FiXtress Schematic Review

12

INT/ pin is an Open Drain pin which the data sheet requires pull-up resistor

 

Schematic Error Example:connectivity verification

Page 13: FiXtress Schematic Review

13

device through the SDA terminal. Notice that if the I2C-bus common pull-up resistors havenot been installed as required for I2C-bus, then an external pull-up resistor, about 10 kOhm,is needed for each of these two terminals.

Schematic Error Example:connectivity verification

The pull up resistor value is not within the required by the manufacturer

Page 14: FiXtress Schematic Review

14

Schematic Error Example: Common rule

The required decoupling capacitor is 10uF in the design the decoupling is 0.1uF

Page 15: FiXtress Schematic Review

Pin 3 is not connected pin but there is a connection to 5 volt

15

Schematic Error Example: Common rule