29
DM : Serial Switching DM : Serial Switching Presented By : Rakesh Dasgupta Presented By : Rakesh Dasgupta Content Content at : http://wp.me/p1Ci5j at : http://wp.me/p1Ci5j-1e 1e

DM Serial Switching

Embed Size (px)

DESCRIPTION

Serial Switching http://wp.me/p1Ci5j-1e

Citation preview

Page 1: DM Serial Switching

DM : Serial SwitchingDM : Serial Switching

Presented By : Rakesh DasguptaPresented By : Rakesh Dasgupta

Content Content at : http://wp.me/p1Ci5jat : http://wp.me/p1Ci5j--1e1e

Page 2: DM Serial Switching

AgendaAgenda

1.About Register Relationships

2.Serial Switching

3.Scenario

4.Demo.

5.Questions .

Page 3: DM Serial Switching

Register RelationshipsRegister Relationships

�This function allows one to map two or more registers into a

relationship. As a requirement The device should have undergone

technical installation.

�One can also define register relationship at the Register Group level.

�There are many types of Register Relationships like.

�Serial Switching Relationship

�Primary Rate – Secondary rate Relationship�Primary Rate – Secondary rate Relationship

�Control Relationship

�Resetting Relationship

�Pulse Relationship

�Usage Hour Relationship

For more information on Register Relationship look into the help.sap site.

http://help.sap.com/saphelp_erp60/helpdata/en/9f/03693582

f4db60e10000009b38f889/frameset.htm

Page 4: DM Serial Switching

Serial SwitchingSerial Switching

�Serial Switching is only for Consumption Registers. Though there are

ways to implement this for Demand Registers but its recommended

to use to only for consumption meters.

�So there can be only one primary meter in a relationship.

�There can be one or more than secondary meters in a relationship.

�A secondary meter can also be a primary meter for other meters

but it would need to be defined in a separate relationshipbut it would need to be defined in a separate relationship

�All secondary meters need to installed in the installation of the

primary meters : Billing Related installation.

�Its recommended that the field ‘Not relevant for Billing’ is selected

for the secondary meters while installing it in primary installation.

�Register Relation ship can be created using transaction EG75.

Page 5: DM Serial Switching

Data Environment of Primary Meter/Installation Data Environment of Primary Meter/Installation

Page 6: DM Serial Switching

Data Environment in Secondary Meter/InstallationData Environment in Secondary Meter/Installation

Page 7: DM Serial Switching

Billing Related Installation for Secondary MeterBilling Related Installation for Secondary Meter

Page 8: DM Serial Switching

Secondary Meter Installed(Billing related) in Primary Inst.Secondary Meter Installed(Billing related) in Primary Inst.

Page 9: DM Serial Switching

Secondary Meter Installed(Billing related) in Primary Inst. Secondary Meter Installed(Billing related) in Primary Inst.

Page 10: DM Serial Switching

Creating Register Relationship Creating Register Relationship –– EG75EG75

Page 11: DM Serial Switching

Primary Meter/Installation Details EnteredPrimary Meter/Installation Details Entered

Page 12: DM Serial Switching

Serial Switching Relationship !!!Serial Switching Relationship !!!

Page 13: DM Serial Switching

Meter Reading for Primary InstallationMeter Reading for Primary Installation

Page 14: DM Serial Switching

Meter Readings EnteredMeter Readings Entered

Page 15: DM Serial Switching

Meter Reading for Secondary InstallationMeter Reading for Secondary Installation

Page 16: DM Serial Switching

Meter Reading for Secondary Meter/InstallationMeter Reading for Secondary Meter/Installation

Page 17: DM Serial Switching

Billing for Secondary InstallationBilling for Secondary Installation

Page 18: DM Serial Switching

Check the Line Item & Billing Quantity !Check the Line Item & Billing Quantity !

Page 19: DM Serial Switching

Billing for Primary InstallationBilling for Primary Installation

Page 20: DM Serial Switching

Check the Line Item & Billing Quantity !Check the Line Item & Billing Quantity !

Page 21: DM Serial Switching

Check the Line Item & Billing Quantity !Check the Line Item & Billing Quantity !

Page 22: DM Serial Switching

Check the Line Item & Billing Quantity !Check the Line Item & Billing Quantity !

Page 23: DM Serial Switching

Entering Meter Reading of Secondary Meter ‘First’ Entering Meter Reading of Secondary Meter ‘First’

Page 24: DM Serial Switching

Entering Meter Reading for Primary Meter Entering Meter Reading for Primary Meter

Page 25: DM Serial Switching

Register Relationship Register Relationship –– Functioning Functioning

Page 26: DM Serial Switching

Register Relationship Register Relationship –– Functioning Functioning

Page 27: DM Serial Switching

DemoDemo

Page 28: DM Serial Switching

QuestionsQuestions

Page 29: DM Serial Switching