16
Version 11.1 Instantly Intuitive VTScada™ is an all-in-one SCADA central for plant and telemetry applications of any size. VTScada at a Glance Common Configurations VTScada's integrated design allows it to scale from single servers to multi-million tag applications. p.2 Transparent Licensing We make it easy for you to determine exactly what you need and how much it will cost. p.3 An Interface Built For Operators Operators can easily navigate pages, explore site maps, plot trends, run reports, and acknowledge alarms. p.4 Secure Remote Access Access your process from anywhere via PCs, laptops, smart phones and tablets. p.7 Intuitive Development Environment The ribbon-based Idea Studio™ helps you start creating professional looking displays in minutes. p.8 Industrial-Strength Reliability Features In seconds, configure automatic failover to redundant servers, historians, and networks. p.11 Advanced Historical Data Management Easily share data with third-party business systems using OPC, ODBC, and Web Services. p.12 Non-Proprietary Connectivity Hundreds of built-in drivers communicate with any combination of PLCs and RTUs. p.12 Scalable Application History The combination of the two allows you to generate highly specialized user accounts in no time. p.12 Refreshingly Good Support 35 developers, programmers, and engineers provide the most reliable, and personal support in the industry. p.14 Hardware and OS Requirements Learn exactly what you need to run VTScada on your desktop, laptop, or mobile devices. p.15 Easy to Try - Demos and Trials Explore our online demos using our Internet Client or download and install a full 90-day trial. p.16

Datasheet: VTScada 11.1 SCADA Software

Embed Size (px)

DESCRIPTION

http://www.trihedral.com - A technical overview of VTScada monitoring & control software from Trihedral.

Citation preview

Page 1: Datasheet: VTScada 11.1 SCADA Software

Version 11.1

Instantly Intuitive VTScada™ is an all-in-one SCADA central for

plant and telemetry applications of any size.

VTScada at a Glance

Common Configurations

VTScada's integrated design allows it to scale from single servers to multi-million tag applications. p.2

Transparent Licensing

We make it easy for you to determine exactly what you need and how much it will cost. p.3

An Interface Built For Operators

Operators can easily navigate pages, explore site maps, plot trends, run reports, and acknowledge alarms. p.4

Secure Remote Access

Access your process from anywhere via PCs, laptops, smart phones and tablets. p.7

Intuitive Development Environment

The ribbon-based Idea Studio™ helps you start creating professional looking displays in minutes. p.8

Industrial-Strength Reliability Features

In seconds, configure automatic failover to redundant servers, historians, and networks. p.11

Advanced Historical Data Management

Easily share data with third-party business systems using OPC, ODBC, and Web Services. p.12

Non-Proprietary Connectivity

Hundreds of built-in drivers communicate with any combination of PLCs and RTUs. p.12

Scalable Application History

The combination of the two allows you to generate highly specialized user accounts in no time. p.12

Refreshingly Good Support

35 developers, programmers, and engineers provide the most reliable, and personal support in the industry. p.14

Hardware and OS Requirements

Learn exactly what you need to run VTScada on your desktop, laptop, or mobile devices. p.15

Easy to Try - Demos and Trials

Explore our online demos using our Internet Client or download and install a full 90-day trial. p.16

Page 2: Datasheet: VTScada 11.1 SCADA Software

Page 2

Common Configurations

Single Server

Redundant Server (see our bundle sheet)

Enterprise / Multi-Plant

Page 3: Datasheet: VTScada 11.1 SCADA Software

Page 3

Transparent Licensing

Full installations of VTScada (i.e., Runtime, Development Runtime) are licensed per operating system instance. Add optional components as

needed. VTScada thin clients (i.e., Internet Clients, Mobile Internet Clients) are licensed by the number of concurrent users. Both full installa-

tions and thin clients are sized by the number of I/O tags the license will support.

1. Choose a License and Tag Count

Integrated Components Included (single installation) Runtime

Development

Runtime

Ru

n a

nd

Op

era

te

Application Server (primary or redundant)

Runtime Client

Widgets and Graphics Library

Historian

Security

Network and Computer Resource Monitoring with SNMP Agent

Alarms and Events Database

Trending and Reporting

Slippy Maps integration

Electronic Operator Logbooks

I/O

Dri

vers

Common (e.g., Modbus, DF1, OPC Client, Omron, GE, Siemens)

Advanced (e.g., DNP3, SNMP, Enron Modbus, BSAP)

Proprietary (e.g., DataFlow Systems, Dexter Fortson, Aquatrol)

DataLogger (e.g., Campbell Scientific, DF1, SCADAPack)

De

velo

p

Automatic Version Control (system-wide disaster recovery, audit tools)

Idea StudioTM Efficient Development Environment (online, offline, multi-developer)

Change Deployment

Scripting and Debugging Tools

ODBC Server, OPC Server, Web Services

2. Select an I/O Tag Count In Version 11, only tags that read and write data to external equipment and software are

counted against your license tag count. Tag counts include those in all applications running

concurrently on the licensed computer.

1,000

5,000

10,000

25,000

To 2,500,000

3. Select Optional Components - Priced by Tag Count

VTScada Alarm Notification System

VTScada Enterprise Connectivity Package (OPC, ODBC, Web Services)

4. Add Thin Clients - Priced by Tag Count Priced by tag count and number of concurrent users via either the VTScada Internet

Client or the VTScada Mobile Internet Client.

Single 5-Pack

Unlimited

Page 4: Datasheet: VTScada 11.1 SCADA Software

Page 4

An Interface Built For Operators

Graphic Display Pages

For most users, displays are the primary interface for

their applications. They allow system information to be

divided logically so operators can easily find what they

need.

Every VTScada application includes standard pages in-

cluding, alarms, trends, reports, remote site mapping,

and sample pages.

Open pages in full screen or windowed.

24-bit / 32-bit ‘true color’ support.

Dual / quad monitor support.

Version 11 - Developers can easily configure pages

to display consistently across PCs, tablets, and smart

phones.

Historical Data Viewer (HDV)

Part of every VTScada application, the HDV combines historical

and real-time data to display a continuous picture of any number

of I/O values. See analog and digital data displayed simultane-

ously. It even supports square root and logarithmic scaling.

Operators can easily...

Add tags, adjust their appearance, and save as a group.

Add encrypted notes to explain atypical readings.

Export any range of data to a file or database.

Display min, max and average values.

Version 11

Re-imagined HDV is easier to read and use.

Select overlapping, stacked or tabular views.

VTScada Report Generator

Every VTScada application includes a page for generating ad-hoc

reports as well as a report tag that you can schedule to trigger

pre-defined reports.

Report tags are time-zone aware and can run daily, weekly,

monthly, manually, or on event. VTScada includes pre-defined

water and wastewater reports.

Add custom script reports and Excel® report templates as need-

ed. Reports can be output to your screen, saved to an Excel

spreadsheet, a template, a database, or an email attachment.

3rd Party Reporting - Leading reporting tools XLReporter® and

Dream Reports® both have integrated interfaces to VTScada.

Version 11.1 - The re-imagined HDV

The VTScada Report Generator

Sample display created

with drag-and-drop elements.

Page 5: Datasheet: VTScada 11.1 SCADA Software

Page 5

Intuitive Page Navigation

The auto-generated Page Menu at the bottom left

lets you move quickly through your application.

Browser-like buttons in the top left corner move you

forward and back through recently visited pages.

Individual operators can pin their most visited pages

to the bottom of the screen.

Hotboxes and buttons provide navigation from any

custom page.

Version 11 - Tiled Page Menu™ - This auto-

generated display lets you view and navigate multi-

ple pages at a time. Larger tiles display live data.

Click to open pages or folders. See recently viewed

pages across the top.

VTScada Alarm Management

The standard alarm page displays current, active, unacknowledged,

disabled, and configured alarms. Sort by date/time and filter by

functional area or priority. Lists include time-stamped events

including log on activity, alarm notifications, and setpoint changes.

Embed customized alarm lists into any custom page.

Easy Configuration - Create any number of alarms and events.

Alarms are pre-configured in Analog Status and Digital Status tags.

View and acknowledge alarms during configuration. Snooze feature

allows alarms to re-arm after a defined period. Configure pop-up dia-

logs for high priority alarms. Print any range of alarms or events.

Version 11.1

Right-click alarms to plot data or view referenced pages.

Shelve alarms to temporarily stop alerts during maintenance.

VTScada Alarm Notification System OPTIONAL

Receive alarm information anywhere via SMS text messages, emails,

pagers, and text-to-voice phone calls. Dial into your system to check

levels and alarm status using your application-level security account.

In addition to acknowledging alarms, you can change setpoints, start

or stop pumps, or send digital commands to equipment. Alarm Noti-

fication shares the same tag and alarm databases as the application.

Alarm Rosters - Create rosters of up to 30 staff members to contact

in sequence until an active alarm is acknowledged. Configure any

number of rosters for the whole application or specific functional ar-

eas. Roster activations are recorded as events in the alarm history.

Acknowledge alarms via email and SMS text message. Now supports

the advanced ‘Salli’ speech engine from IVONA®.

Mobile Alarm Management - Though the WAP server is still

supported, it has been superseded by the Mobile Internet Client.

Tiled Page Menu

The Standard VTScada Alarm Page

In the event of an alarm: Click the icon in the top

corner of every page to open the Alarm Page.

Page 6: Datasheet: VTScada 11.1 SCADA Software

Page 6

Operator Interface Continued

VTScada Slippy Maps

Put Your SCADA System on the Map

Familiar Interface - Interact with your remote sites in

the same way you use online mapping tools like

MapQuest®. Pan and zoom across all your sites with a

simple click, toss, or scroll.

Embed dynamic maps into any page or use one of the

standard map pages.

Pick a Pin to See a Site - Sites are represented by pins

that change color based on polling status. Click to open

each site. Easily drag pins into place or position them

with latitude and longitude coordinates.

Cached Map Tiles - Online applications download map tiles from on-line map providers like MapQuest® *. You can pre-load tiles for offline

applications or load custom tiles created with third-party graphics programs. Once displayed, tiles remain cached indefinitely.

Mobile Mapping at Your Fingertips - The VTScada Mobile Internet Client supports slippy maps on mobile devices.

* Map tiles from commercial and open source websites may be subject to terms of license, or use agreements, compliance with which is the user’s responsibility.

Encrypted Operator Notes

No More Paper Logbooks

Are you required to keep a paper logbook for traceability of users'

actions? VTScada improves this process by providing a searchable

electronic operator's notebook.

Threaded Notes - Notebooks act as bulletin boards, providing a

way for users across organizations and across shifts to communicate

and record activities. Search notes by date and print any range.

Tamper-Proof - All notes are time-stamped and include the user's

name. Once created, they cannot be edited or deleted. The entire log

is an encrypted file that cannot be read or edited outside VTScada.

Distributed - Create any number of notebooks and share each of

them on any number of displays.

Accessible - Networked notes are accessible by authorized users

from any workstation or web client.

Version 11.1

Create multiple notebooks for operator logs.

See HDV and Operator Notes in one display.

Add comments to existing threads.

Save time with commonly used note templates.

Sticky Page Notes

Leave messages and reminders on any or every page.

Cover monitoring and control elements to discourage use.

Easy to create, format, and edit.

Hide all notes with a click.

Auto-generated Slippy Maps for

PCs and mobile devices

Search encrypted notes by date

Version 11.1 - The Re-imagined Operator Notes Interface.

Posting a note is a snap.

Page 7: Datasheet: VTScada 11.1 SCADA Software

Page 7

Secure Remote Access

VTScada Thin Clients OPTIONAL

Monitor and control your process from any networked

Windows PC or mobile device. See page 15 for supported

devices and operating systems.

Simple Licensing - Clients are licensed by concurrent

users and require at least one installed Runtime or

Development Runtime license. Individual and bundled

pricing is available.

Fully Integrated Internet Server - No need for third-party

products like Apache® or Microsoft IIS®.

Configure in Seconds - No need to rebuild your

application screens.

Military-grade Encryption - Support for Transport Layer

Security (TLS) protects security data exchanged between

clients and servers.

VTScada Internet Client (VIC) PCs and Laptops

Perfect for use as either...

A Secure Remote Portal - Log on from your home or an internet cafe

across the world. All you need is an online Windows computer.

A Flexible Local Workstation - VIC pages look and behave like

Runtime workstations. This, plus industry-standard security, and

automatic failover, makes the VIC a hassle-free alternative to full instal-

lations at your facilities.

Version 11.1 - Open the VIC with any standard Windows web browser.

Mobile Internet Client (MIC) Smart Phones and Tablets

Instant access from anywhere using HTML5-compliant devices such as

Android®, iPhone®, and iPad®.

View and acknowledge alarms, check levels, set values, plot trends, and

issue control commands with a touch or pinch. Set a refresh rate that

suits your cellular data plan or manually as needed.

View your screens in one of two ways.

Optimized Mobile Interface - We designed this tactile easy-to-read

interface to make the best use of smaller smart phone screens.

Full Graphics Interface - Version 11 - To make better use of larger

tablet screens, the MIC now allows you to instantly switch to full-

resolution page views, just as they appear on Runtime workstations.

Pinch to zoom in and out of areas of interest. Full graphics use more

of your mobile data capacity.

Client 2

Field Laptop

Client 3

Head Office

Client 4

Lift Station

Optimized

Mobile Interface

Full Graphics

on the MIC

Mobile

Slippy Maps

VTScada Internet Client (VIC)

Client 1

Home Computer

Page 8: Datasheet: VTScada 11.1 SCADA Software

Page 8

Instantly Intuitive Development Environment

The VTScada Idea Studio™

Start Creating Great Displays in an Hour

So often, SCADA graphics end up looking sloppy or lack-

luster because there simply wasn't the budget to make

them look great.

Developers may only have enough time to get the data

on the screen before they have to move on.

We designed the VTScada Idea Studio™ to be instantly

intuitive with a huge library of built-in drag-and-drop

elements that are easily selected and aligned. Zoom right

in for the fine details. No more messy screens.

Version 11.1

Enhanced page tag management in the Idea Studio.

Even more style and formatting options for Widgets.

Familiar Ribbon Interface - The context-sensitive toolbar is easily customized

to put elements right where you want them.

Flexible Tag Development - If you like to lay out graphics first and create tags

later, you can. If you'd rather start with tags, you can do that too. Search and

replace any tag referenced by a page.

Over 200 New Graphic ‘Widgets’ - It's a snap to represent your system

values as photo realistic meters, switches, buttons, and animations.

Extensive Graphic Library - Includes over 4,500 industry-specific images,

symbols, polygons, and data-driven animations. Import BMP, JPG, WMF, and

EMF formats by dragging them from your desktop.

Photo Realistic Background Tiles - Create a consistent look and divide pag-

es into areas of interest. Drag on and resize over 100 patterns.

Lighting Overlay Tiles - Add depth to pages and direct the focus of operators.

Style Settings Tags - Create consistent display conventions for groups of

Widgets (e.g., red for "off" and green for "on"; or vice-versa).

Auto Alignment - Snap points effortlessly align and space graphics for you.

Simple Pipe Drawing - Draw 3D pipes with a few points and clicks. Animate

color based on calculations or tag values.

True Color SCADA - For vibrant looking displays and reports, VTScada

supports 24-bit/32-bit ‘true color’. Use the color selector to pick from over 16

million colors. Script functions also support true color graphics.

Build Once, View Anywhere - Build displays for multiple monitor resolutions.

Pages can be full screen or pop-up windows. Configure dual or quad monitors

on compatible computers. The Mobile Internet Client also displays full graphics.

Drag and Drop Graphic Widgets

Photo Real Background Tiles and Lighting Overlay

Tiles

Page 9: Datasheet: VTScada 11.1 SCADA Software

Page 9

Configuration Management

Real-Time Configuration

Reduce downtime by editing tags and displays (plus many

source code and property changes) without restarting.

Multiple users can configure simultaneously without a

configuration server. Conflicts are resolved automatically.

Push validated changes to all networked computers

manually or automatically.

Edit tags via VTScada Internet Clients and edit server lists

from VTScada Runtime licenses.

Distribute Applications in a Single File

VTScada ChangeSet Files

Reduce integration costs by distributing new or updated applications to multiple computers with a single file that can be easily shared via

email, FTP, memory stick, or CD. Users with limited technical knowledge can easily create and apply ChangeSets without restarting.

Reuse work by cloning existing applications.

Backup/restore applications with version history.

Update OEM layers without affecting end user applications.

Send applications to your support team.

Application Version Control (AVC) STANDARD IN DEVELOPMENT RUNTIME LICENSES

Unique to VTScada, AVC provides change traceability, enhances

application management in networked environments, and greatly

improves recovery from unexpected effects of configuration.

See a history of all changes by all users on all servers.

Burrow into versions to see side-by-side incremental changes.

Instantly switch to any previous good version.

Merge changes in multi-developer environments.

Advanced Customization

VTScada Scripting Language

In addition to the drag and drop toolset, VTScada provides a powerful object-oriented scripting language (similar to C++) that allows unlimited

customization of almost every feature. All saved code changes are recorded in the application version control system and can only be imported

by developers with this security privilege. Examples include custom services (e.g., to start tasks or watch for events), custom tag types, custom

drivers, and custom API calls to 3rd-party software products.

VTScada Scripting Debugging Tools

Million thread history with dead thread identification.

Tracing of all VTScada activities.

View device driver error stats and sent/received.

Source debugger highlights what code has been run/tested.

Soft Logic Control

Alternative data sources for output controls:

Deadband tags with delay and hysteresis (deadbanding).

Calculation tags with mathematical and logical functions.

Expression tags with complex scripting logic.

Concurrent development with

automatic conflict resolution

VTScada Application Version Control

Page 10: Datasheet: VTScada 11.1 SCADA Software

Page 10

Advanced Tag Management

Get The Most From Your Tags

VTScada uses tags to manage application resources such

as I/O, calculations, modems, alarms, fonts, and

menus. This allows resources to be easily maintained

in a single database.

Version 11 - Since VTScada is licensed by the number

of tags used, we wanted you to get the most from your

chosen tag band. Now, only I/O and calculation tags

count towards your tag count. This frees you to include

an unlimited number of menu items, fonts, alarms,

and any other configuration tag types.

Version 11.1 - Right-click individual tags to plot data or

view pages that reference that value.

High Efficiency Tag Development

Create and edit tags outside VTScada via Access®, Excel®, and SQL

Server®.

The Multi-write tag writes up to 50 outputs with one action (useful for

starting HMI or replacing PLCs).

History Statistics tag displays calculated values.

Trigger tag initiates actions based on time or changes.

Add manual tag values to test systems without live I/O.

Rate-of-change tag detects rapid value changes indicating leaks or lack of

change indicating failed pumps or valves.

Special analog and digital tag types include alarms and logging.

Pump Status tags include high/low alarms, delays to reduce alarms due to

minor changes, and pre-configured reports.

New tags 'Log on change' to only save meaningful data to the DB.

New I/O tags flagged as ‘Questionable’ to assist commissioning.

Hierarchical Tag Browser

Create and manage tags using the VTScada Tag Brows-

er. Model how your real-world elements relate to one

another by nesting child tags within parent tags. If you

see a pump as an assembly of I/O and communications

drivers, you can define it that way. If the pump is one of

many in a lift station or other assembly, you can make it

a child of the lift station tag.

Build structures once and reuse them many times.

Clone whole subsystems by simply copying the root of a

tree of tags. Copied tags automatically reference their

new scope. Multiple tag selection saves significant time

when copying, enabling, disabling, or deleting more

than one tag. Now you can rename and reorganize tags

without losing tag history, page references, or alarms.

Reusable Templates - Tags and Graphics

To simplify configuration of applications with many similar assets, tag

structures and graphics can be combined into reusable Page Tag templates.

Both tag and graphic templates are easily copied and modified via simple

copy/paste tools.

Built-in Templates - VTScada comes with a pre-defined Page Tag templates

for two Remote Telemetry Units (RTU) with configurations that are relatively

consistent from device to device: Xylem Multismart, and MPE Pump Control-

lers. These may also be used for similar devices or as useful examples.

Included Templates - Alarms, analog and digital inputs, analog setpoints &

digital controls, summary starts/stops counters and runtime totalizers, data

age and communication link status indicators, latitude and longitude with

slippy maps support.

The VTScada Tag Browser

A Premade Lift Station Template

Page 11: Datasheet: VTScada 11.1 SCADA Software

Page 11

Industrial Strength Reliability Features

Redundancy and Automatic Failover

To protect your critical process, we developed the most reliable, comprehensive, and user-friendly approach to SCADA redundancy.

In minutes, configure hot back-up failover for each of the following:

SCADA Servers

Configure any number of thick client workstations as

redundant servers with automatic failover. Each server

maintains a complete copy of the application’s tags, security

settings, displays, scripts, networked variables, and

configuration history. All historical database servers

synchronize automatically. Share CPU load for most services

across multiple computers. Supports two redundant alarm

servers per application.

Internet Servers

If a server goes offline, client connections seamlessly switch to

the next designated server. Supports unlimited servers. (Each

server requires a separate VTScada software license.)

I/O Connections

The VTScada Driver Multiplexer provides seamless failover to

back-up communication networks or I/O devices (serial,

ethernet, dial-up, DNP3, and radio).

Historical Databases

VTScada also supports any number of redundant,

synchronized historians spread across multiple servers.

Real-Time Backup of History and Configuration

VTScada's integrated design and fast network syncronisation means that you can configure any redundant thick client workstation to...

Include a copy of the latest configuration history.

Include a synced copy of the historical database.

Be an offsite backup that is always up-to-date.

Never forget another backup!

VTScada as a Service

Version 11.1 - Run VTScada without a logged-on Windows user.

Run VTScada as an interactive program, or as a service.

Once installed, the service automatically starts when

Windows® starts.

Useful where security policy forbids leaving a logged-on

Windows user on a server.

Workstation Health Monitoring

VTScada allows you to monitor and individually alarm critical

computer resources including CPU usage, virtual memory

used, and hard drive space.

Automatic Server Failover (Application and Internet Servers)

Automatic Failover to Redundant Networks or Devices

Redundant geographically

separated Historians

Protocol 1

Protocol 2

An example of a custom Workstation Health Dashboard

Page 12: Datasheet: VTScada 11.1 SCADA Software

Page 12

Advanced Historical Data Management

Built-in Data Logging

The VTScada Historian is pre-configured in every application. Tags that

receive data begin logging automatically. Built for speed, the Historian

can log up to 4,000 values/sec. Protect data using multiple redundant,

synchronized historians at multiple sites that sync across a WAN at up

to 160,000 values/sec. In addition to the native Historian, VTScada also

supports Oracle®, SQL Server®, MySQL®, and SQLite® database for-

mats. Log on time of day or changes in value. Use deadbands and

delays to avoid recording irrelevant changes in values.

Enterprise Connectivity Package

Version 11 - Now standard in Development Runtime Licenses.

VTScada OPC Server - Allows OPC-compliant programs (including other VTScada applications with OPC clients) to send and receive live data to

and from a standard VTScada application.

VTScada OPC Client - Allows VTScada applications to send and receive live data to and from an OPC-compliant server (including VTScada appli-

cations with configured OPC servers).

VTScada ODBC Server - Use industry standard software like XLReporter®, DreamReport®, Crystal Reports®, Microsoft Access®, or Excel® to

extract system data from VTScada applications. VTScada acts as a database where each logged tag represents a table of timestamps and values

that reporting software can query to retrieve logged values. XLReporter® and Dream Reports® both have integrated interfaces to VTScada.

VTScada Web Services - This SOAP (XML) interface allows business systems to request real-time and historical data from VTScada applications.

Supports time/date ranges, min, max, time of min, time of max, ave, total, and SQL that include SELECT commands and WHERE clauses.

Non-Proprietary Connectivity

Device Driver Library Use OPC by Choice, Not Necessity

VTScada provides maximum flexibility when choosing monitoring and control devices by supporting over 100 industry standard and

proprietary I/O protocols. All drivers include communications alarms. New drivers can be created to meet your specific needs.

Common Protocols DNP3, DF1, Modbus (serial, TCP/IP, RTU), OPC, SNMP, DDE

Data Logger Protocols Enron Modbus, Campbell Scientific Pakbus, Stevens

Proprietary Devices Motorola, GE, Siemens, Omron, BSAP, DFS, Dexter Fortson

Radio Diagnostics Drivers MDS, DataRadios®

Native Polling Driver VTScada gives you the option to replace a master PLC reducing cost, set up, and points of failure. VTScada automatically organizes scheduled

polling cycles and communications channels to simplify device communications and reduce integration time. Transmit multiple protocols on a

single communications link to reduce the number of required radios. Configure any number of independent polling groups.

Select 'Fast Poll' mode to set a higher polling frequency for specific RTUs.

Use external triggers to poll on infrequent schedules or on command.

Enable or disable polling in any polling driver.

Modem Management Pool modems across servers for improved efficiency.

Includes custom Unimodem driver.

Supports logging of modem activities.

Supports dedicated modems for functional areas.

Data and Alarm Notification requests routed to appropriate voice

and data modem(s). No configuration necessary.

Graphics show modem events, usage stats and modem status.

Page 13: Datasheet: VTScada 11.1 SCADA Software

Page 13

Scalable Application Security

More Control, Less Complexity

We strive to make security management simple, scalable, and

infinitely configurable. Authorized users can manage security

within the standard operator interface, then instantly deploy

their changes across the entire system without restarting.

Version 11.1 - Windows® Security Integration

Log on to VTScada using your Windows account.

No need to manage both Windows and VTScada accounts.

Version 11.1 - Proximity Card Readers

Log on the same way you enter a secured building.

Configure Operator Notes to require authentication.

A Smarter Approach to Account Management

Each application includes security accounts and settings that control access to the entire

application including workstations, thin clients, mobile clients, and the VTScada Alarm Notification

System. Authorized users can easily add, delete, copy, and modify accounts. Rather than choosing from

an ever-growing list of privileges, VTScada uses 'Rules' and 'Roles' to allow you to quickly generate highly

specialized user accounts.

Rules - A combination of tags, privileges, and locations that allows you to finely tune what users can do and from where. This allows you to

grant some users access to one part of a plant and others access to another part without creating any new privileges.

Roles - A set of Rules (and other Roles) corresponding to the duties of a specific job such as an operator at a specific plant.

Unparalleled Traceability

Operations - Operator activity such as setpoint changes, logon/logoff, security modifications, and Alarm Roster activations are recorded as

events by the VTScada Alarm Manager. This includes actions performed via servers, Thin Clients, and the VTScada Alarm Notification System.

Configuration - VTScada's built-in version control automatically tracks all changes made by all users on all workstations. It also detects manual

changes to configuration files made by unauthorized users or malware, and automatically restores them to their correct state. The repository

includes hash codes to detect any attempts to modify it. Authorized users can see this change history and instantly switch to any revision.

Remote Access - The VTScada Internet Client Monitor displays and logs VTScada Thin Client activity. Send messages to clients and force

disconnection if malicious activity is suspected. Logs user IP, computer name, screens viewed, session length and other audit parameters.

Advanced Encryption and Network Protection

Security database employs military-grade encryption as does the security information exchanged between Internet clients and servers.

The security manager complies with industry-standard RFCs for security.

User passwords are “hashed” meaning they are never held in a form that anyone can decrypt and recover.

Time-stamped operator and trend notes are also encrypted to prevent deletion or modification.

The VTScada Internet Client supports TLS (Transport Layer Security), firewalls, and VPN access.

When emailing alarm notifications, VTScada now supports SMTP email servers requiring Transport Layer Security (e.g., Gmail™).

Optionally configure a list of IP addresses that may or may not be permitted to connect to your application.

User-configurable IP port address and server failover methodology.

If an unauthorized user attempts to modify a configuration file, the change will automatically be detected at startup and the current ap-

proved configuration file will be restored from the tamper-proof repository.

Page 14: Datasheet: VTScada 11.1 SCADA Software

Page 14

Support, Renewals, and Upgrades

The VTScada Support Team

If you have ever been frustrated while trying to access help from a major

supplier, you will find our dedicated personal approach to be a refreshing

change. Our team of developers, programmers, and engineers provide the

most accessible, reliable, and comprehensive support in the industry.

Consequently, our customers keep coming back for upgrades, enhance-

ments, and consulting services as their facilities grow and their needs

evolve. Note that support packages do not include hardware troubleshoot-

ing, training, or system design.

Choose the Level of Support You Need

Type Coverage Price Includes

SupportPlus

Service

First 90-days

Monday to Friday

8 to 4 PM EST

Included with software purchase.

VTScada software specific (Non-application specific)

Phone, fax, and email support

Seamless version compatibility

Product upgrades and value protection

SupportPlus

Service

Yearly Renewal

Annual

Monday to Friday

8 to 4 PM EST

15% of purchase price so long as

support never lapses.

VTScada software specific (Non-application specific)

Phone, fax, and email support

Seamless version compatibility

Product upgrades

Value protection

SupportPlus

Service

Re-instatement

Annual

Monday to Friday

8 to 4 PM EST

15% per lapsed year, cumulative up

to 75%,on current license value.

Recalculated license value carries

forward.

VTScada software specific (Non-application specific)

Seamless version compatibility

Product upgrades and value protection

SupportPlus

24/7

Emergency Support

Annual

24/7 5% of license value (min $1,200)

VTScada software specific (Non-application specific)

Phone, fax, and email support

Requires active SupportPlus contract

Nights, weekends, holidays

SupportPlus

Premium 8/5

Annual

Monday to Friday

8 to 4 PM EST

Based on application

Contact Trihedral

Dedicated support team trained on your application

Guaranteed response times

Remote application access for hands-on diagnostics

Unlimited email and phone support

SupportPlus

Premium

24/7

Annual

24/7

Based on application

Contact Trihedral

Dedicated team trained on your application

Unlimited email and phone support

Guaranteed response times

Remote application access for hands-on diagnostics

Ad-hoc Support

Hourly

As contracted

Contact Trihedral

$130/hr or £85/hr

Plus expenses

Application-specific support

On-site, email, phone

Software Training Courses

Courses are available at our Bedford and Orlando training facilities or on-site anywhere in North America upon request.

Operation & Configuration - An intro to VTScada for SIs, OEMs, consultants, operators, maintenance, and IT staff.

Introduction to Scripting - Customization and configuration using VTScada Script for advanced developers.

Advanced Configuration and Scripting - For advanced system integrators and OEMs

Custom courses can be created based upon specific user requirements.

See available courses - www.trihedral.com/training

The VTScada Support Team

Page 15: Datasheet: VTScada 11.1 SCADA Software

Page 15

Hardware and OS Requirements

For Installed Runtime or Development Runtime Licenses

The following is a guide. Actual requirements will depend upon your specific application architecture.

Minimum Requirements

Servers or Workstation PCs

32- or 64-bit Windows Operating System

2GHz dual-core processor

20GB free hard drive space

8GB RAM

Laptops, Tablet PCs, and Panel PCs

32- or 64-bit Windows Operating System

2GHz dual-core processor

20GB free hard drive space

4GB RAM

Additional Recommendations

64 bit versions of Windows (you can run 32-bit VTScada on 64-bit OS)

3GHz dual or quad core processors (more cores won’t help, higher clock speeds will)

16GB or more of RAM for systems over 100K tags

Solid State Drives (SSD) for the highest performance

Avoid using RAID for the VTScada historian (fine for Oracle®, SQL, MySQL®)

Keep historian on a separate hard drive from VTScada and the OS

Windows-compatible printer to print VTScada pages or reports

100MB/1GB Ethernet required for networking

Voice modem required for voice phone notifications by Alarm Notification System

Sound card and speakers are required for alarm annunciation

RS-232 port if needed for communications with serial I/O devices

VTScada supports virtual servers. However, more than one VS on one computer,

where one of them (i.e., VTScada) is mission critical, is not recommended

Compatible Operating Systems by Version

VTScada

Version Win 8.1 32 & 64-Bit

Win 8.0 32 & 64-Bit

Win 7 64-Bit

Win 7 32-Bit

Vista 64-Bit

Vista 32-Bit

Server 2012

Server 2008

Server 2008 R2

Server 2003

8.X

9.X

10.X 1. 1. 2.

11.X 1. 1. TThhiinn CClliieenntt OOnnllyy

Windows 7 Embedded® has been tested for some Panel PC implementations. Contact us for details.

Please Note

NetDDE is not available on Windows Vista and higher (it was removed in XP Service Pack II).

VTScada 10 uses IANA registered TCP/IP port 5780 (not 1160). Configure your firewall to route RPC traffic accordingly.

When reusing internal devices like modems or sound cards, make sure that the new computer has the correct motherboard slots.

Make sure the third-party software you use with VTScada (e.g., accounting or reporting) is compatible with the new OS.

There are no A-Open modem drivers for an OS newer than Vista. Contact us to learn more about selecting and configuring modems.

1. Server 2008 computers often require speakers or audio cards for some Alarm Notification functionality. Manual modem configuration may be required.

2. Server 2003 requires this hotfix to be installed: http://support.microsoft.com/kb/938397

For Thin Clients on Smart Phones, Tablets, Desktops, and Laptops

Windows Desktop/Laptop Systems

The VTScada Internet Client

Requires at least one installed VTScada License to act as the server

Requires one or more concurrent VTScada Thin Client licenses

Launch clients from any networked computer running Windows Server

2003 or newer (no VTScada installation required)

Launch using Internet Explorer (ensure ActiveX is enabled) using a web address

Launch from your desktop using a small program downloaded once from your

VTScada server via any browser

Other Operating Systems

VTScada Mobile Internet Client

Network connection to a VTScada server

Designed for any HTML5-compliant web browser

Recommended Browsers

Safari® (OS X, iOS)

Chrome® (Windows®, iOS®, Android®)

Other examples of HTML5-compliant Browsers

Opera® (Windows®, iOS®, Android®)

Firefox® (Windows®, iOS®, Android®)

BlackBerry Browser® (BlackBerry OS®)

Internet Explorer Mobile® (Windows Mobile®)

Page 16: Datasheet: VTScada 11.1 SCADA Software

Page 16

Easy to Try

VTScada Trials and Demos

We could fill hundreds of pages with more features and bullet

points but we believe the best way for you to learn about our

software is to try it for yourself.

To get started, we invite you to visit our website.

www.trihedral.com

Right on the front page you will find links to our trials and

demos or you can just use the links below!

If you have any questions, don't hesitate to call us.

1-800-463-2783

Toll-free in North America

Online Demos

Without installing VTScada you can instantly explore a working SCADA

application using the VTScada Internet Client or Mobile Internet Client.

The fully functional operator interface includes alarms, trends, maps,

and examples of industry-specific displays from real-world applications.

PC: Trihedral.com/pcdemo

Mobile: Trihedral.com/mobile

Full 90-day Trial

In just minutes, you can download a full version of VTScada to install on

your Windows computer. Just one install allows you to try all core

SCADA components* including the VTScada Idea Studio where you can

start creating your own professional-looking custom screens.

PC: Trihedral.com/trial

* Trial does not include text-to-speech alarm notification which requires an installed voice modem.

Updated February 13, 2015

© Trihedral Engineering Limited 2015 – All Rights Reserved

VTScada is a trademark of Trihedral Engineering Limited. Blackberry, iPhone, iPad, iPod Touch, Android, Crystal Reports, XLReporter, DreamReport, Oracle, SQL Server, MySQL, SQLite,

MapQuest, IVONA, Salli, Motorola ACE, MOSCAD, Google, Gmail, MultiTrode, MultiSmart, Apache, DataRadio, Allen-Bradley, Microsoft, IIS, Excel, Opera, Firefox, BlackBerry, Chrome,

Android, iOS, OS X, Windows 8, Windows 7, Vista, 2008 Server, XP, and 2003 Server are trademarks of their respective owners.