5kW on grid case study, Chennai, India

Embed Size (px)

DESCRIPTION

Case study - 5kW on-grid solar inverter

Citation preview

Page 1: 5kW on grid case study, Chennai, India
Page 2: 5kW on grid case study, Chennai, India

• About us

• Zigor – On grid Solar Inverter and Features

• Site condition

• Site pictures

• Performance of the plant

• SCADA

Page 3: 5kW on grid case study, Chennai, India

About us - Zigor Corparacion. S.A.

Page 4: 5kW on grid case study, Chennai, India

About us - Zigor Corparacion. S.A. Global Presence

Page 5: 5kW on grid case study, Chennai, India

Zigor – On grid solar inverter

• The ZIGOR SOLAR TL1 inverters combine design and versatility with ease of operation.

• An outstanding feature of these inverters is their 96% efficiency without transformer.

• The ZIGOR SOLAR TL1 range stands out because of its RS-485 communications with the centralized supervision and control system and all its parameters can be configured locally (optional).

Page 6: 5kW on grid case study, Chennai, India

Features

High efficiency

Good voltage and frequency

range for synchronization

IP 65

Outdoor Unit

LCD display

2 MPPT

120-500Vdc range

Page 7: 5kW on grid case study, Chennai, India

Standards and Certifications

Page 8: 5kW on grid case study, Chennai, India

Site Condition

• Since the plant was commissioned during the construction of buildings, a lot of diesel fuel & grid power cost was saved which was beneficial for the customer.

• No battery bank – because the system is a on-grid inverter

• 3rd party SCADA system is installed at the site to monitor the daily performance of the solar PV installation & inverter performance

• The grid is stable at the site with variation of voltage from 200 – 240V AC and our inverter adapt to change in grid conditions and work accordingly.

Page 9: 5kW on grid case study, Chennai, India

Chennai Site - Location

Page 10: 5kW on grid case study, Chennai, India

Site Pictures – During construction

Page 11: 5kW on grid case study, Chennai, India

Site Pictures

Monitoring system

String inputs

Page 12: 5kW on grid case study, Chennai, India

Plant performance

• The load is continuously powered with the help of solar power that is being generated

• The current generation is around 30 - 33 Units a day (Jan,2014) which is approximately 6.6Units of electricity generation per kW (please note the DC side was oversized by 20% extra)

• Please find the SCADA details attached in the next slide, you can see the following – The Daily solar generation

– The hourly generation

Page 13: 5kW on grid case study, Chennai, India

SCADA

Daily generation – (28 to 30th Jan, 2014)

Page 14: 5kW on grid case study, Chennai, India

SCADA

Hourly generation – 30/01/2013

Page 15: 5kW on grid case study, Chennai, India

Interested with our product?

Please contact us to get direct feedback from the rooftop customer

(or)

arrange for a site visit

Page 16: 5kW on grid case study, Chennai, India

Thank you!

Please contact us for more details

Giridaran Srinivasan

Senior Engineer

+91-98407 82354

www.zigor.com

THANK YOU

Page 17: 5kW on grid case study, Chennai, India

Q&A

Q&A