Plates
4. Spheroid Imaging with the CV7000 Platform Spheroid models
have become common for research applications such as drug discovery
and toxicity assays. Corning 96-well round bottom ultra low
attachment spheroid microplates enable cells to form a spheroid
centered in each well. This typicall requires 2-3 days incubation.
The 96-well and 384-well formats are useful formats for high-
throughput screening. The challenge has been imaging the spheroids.
The CV7000 Platform solves this challenge
5. Spheroid Imaging with the CV7000 Platform 1 hour 127 hours
11 z-slices at 10 micron intervals 100 microns total
6. Spheroid Imaging with the CV7000 Platform Timepoint (hr)
50000 45000 40000 25000 30000 35000 Area(m2) 0 6545 55
60504035302520155 10 Spheroid Growth based on image area
7. Cell Voyager 7000 Configuration
8. Simultaneous Imaging with 1 - 3 Cameras sCMOS Cameras -20C
5.5MP = 2,560 x 2,160 6.5m pixel
9. Objective Choices
10. Choose Up To 6 Lenses Dry: 2x, 4x NA .16, 10x NA .4, 20x NA
.75, 40x NA .95, 20x NA .45 LWD Water Immersion: 40xNA 1.15, 60x NA
1.2 Phase Contrast: 10X, 20X
11. Plate Type Well Size Lens 96 well 6.5mm 2x objective 384
well 3.25mm 4x objective 1536 well 1.5mm 10x objective Complete
Well FOV
12. Imaging Modes Confocal Epifluorescence Phase Contrast
Bright Field
15. Visualize dynamic events in live cells Loader for Reagent
plates Loader for Disposable tip racks 5l - 20l (384-well) 10l -
100l (96-well) Single tip dispensing Kinetics Module - Live
imaging
16. Reagents added with disposable tips Choice of 96-well,
384-well Multiple dispenses possible Begin imaging before
dispensing Continue imaging during dispense Imaging speed 8 fps (no
binning) Cut away view of Dispenser with CV7000 case removed
Kinetics Module - Live imaging
17. 2x binning: 15 fps at 1 color 7.5 fps at 2 color. 3x
binning: 38 fps at 1 color 20 fps at 2 color Exceptional Image
Quality Kinetics Module - Live imaging Imaging Speeds
18. Confidential CV7000 Update January 2015 - AstraZeneca
SearchFirstTM Automated Hit Finding Save Valuable Time Reduce
Screening Costs Improve Imaging Results Key Capability
19. SearchFirst quickly finds specific fields of interest
(hits) throughout a plate, and then re-scans those specific fields
of interest - automatically. 1. Low resolution scan of all wells
(4X, 10X) 2. Images sent to analysis platform, hits returned 3.
High resolution scan of hits (40X, 60XW) SearchFirst
20. SearchFirst uses the full flexibility of the CV7000
interface enabling choice of colors, objectives, FOV, binning, and
time lapse settings within a plate and even within a well
(different fields within a well can have different settings).
SearchFirst
21. Most Flexible Imaging Live cell imaging for days Unmatched
speed Proven reliability Yokogawa CV7000