15
Best solution for Energy Consumption Optimazation

In power point description and application

Embed Size (px)

Citation preview

Best solution for Energy Consumption Optimazation

Module- optimizer ECOD

Feigin Electric solution-Module Optimizer “ECOD”

New product which allows you to optimize the voltage within the norms laid down by international standards of quality electricity.

By optimizing the consumption savings of up to 10% more.

Registers the change of power quality input and output devices.

Measures and records the power consumption and energy consumption in almost any period of time.

The device operates in three phases simultaneously.

Increases the lifetime of electrical production.

Not sensitive to instantaneous load. Large high contrast display with instant

readings of the physical quantities of electricity.

Programming with the unit.

.

Description and application Our goal in the development of: Transformer circuit without introducing harmonic distortion. Output voltage network standards. Current on demand - improving the electric starter motors and reactive load. Small domestic energy consumption. High reliability. Low cost. Lineup covers any load current. 50, 100 , 200 ... Lightweight. Ruggedness to the climatic conditions. Economic effect. 10% or more The outer and inner assembly. Possibility of remote monitoring. Micrologic The ability to implement in a computer network companies. Modbus Readings consumption standards. ISO Programming for the options you want in your network. ION Setup Reliable components. Schneider-Electric Quick modular repair. Quick return on investment. Not a complicated installation. Overvoltage protection. Comparing these factors you will not find analogues!

Operation principle

The principal distinguishing features of our device "module optimizer - ECOD» and other voltage regulator in the power

supply.

1. The efficiency of our devices is 0.997 (all known stabilizers for industrial use, efficiency does not exceed 0.96)

2. 2. The transmission ratio of the electric power network by the electromagnetic load our device is 1:15 While all known stabilizers for industrial use power transmission ratio is 1: 2 (this means that the capacity of the autotransformer all other known stabilizers for industrial use shall be not less than half the power of the load, which means that these devices are more dimensions, the greater the weight, cost a lot more. These devices consume up to 5% of the electricity for their own needs - in connection with which the devices does not make sense to use optimizers as power consumption.

3. 3. The power load can vary from 0 to 100%, which does not affect the quality of regulation.

4. 4. The regulatory process takes place without breaking the circuit and distortion sine wave voltage.

5. 5. Performance when switching does not exceed 20 ms.6. 6. High efficiency and low cost devices allows their use in electric networks

with a voltage of more than 220V to optimize energy consumption, with payback periods of less than 1.5 years, which can not provide any of the known devices.

Implementation Principle

Implementation Principle Street Lighting Module-Optimizer “ECOD” provides up to 28% energy savings for the

following reason: Voltage control of a network of street lights reduces the cost of maintenance of lamp replacement.

Module-Optimizer “ECOD” allows lighting fixtures require a lower amount of energy without affecting the amount of lighting, but significantly reduces cost.

Advantages include: Easy installation, anywhere. A lightweight and compact unit means easy

installation on any open apparatus for lighting control. Fast return on investment within 10 – 24 months. Reduces the cost of maintenance by prolonging the life of lamps. No additional charges to the existing infrastructure. The finished

product Module-Optimizer “ECOD” lighting provides immediate energy efficiency and savings.

Implementation Principle

Implementation Principle

Basic economic effects from the use of our equipment:

1. The total result of implementation of equipment in the energy system of the country, can be optimization up to 10-20% of electricity consumption, and thereby actually get new free capacity in a range of 10-20% of the existing ones.

2. Increase in the 1.5-2.5 times the service life of electrical equipment.

3. An increase of 10-15% Stability power producers (all generators electric stations throughout the country's energy system).

4. Due to the integrated use of our equipment in the power system of the country, you can increase price of a kilowatt of electricity by 10-20% without any impact on economy and population. The total value of payments will not increase, because of reduced consumption due to optimization. The resulting income can be used for modernization of electric networks and construction of new power plants, which will be necessary to build due to increase in electricity consumption.

Best Solutions to optimize energy consumption!

Do you know that current in a socket never complying with standards 220 V or 230 V, 110 V or 120 V? Yes, that statement is absolute truth.

You barely found 220 V or 230V, 110 V or 120 V (depends on country accepted standard) it’s almost always plus or minus 5-10%.

Usually, in large cities voltage close to the upper tolerance range.

Best Solutions to optimize energy consumption!

For example, in a country where 220 V taken as a basic in network will be 225V-235V and even more. Distributors increase the voltage to control subsidence at peak power consumption.

This increase is a main cause of "unnecessary" electricity use and unreasonable electric bill.

By implementing our technology electricity distributors simply can optimize consumption by reducing the voltage to the border which close to the lowest acceptable standards.

Best Solutions to optimize energy consumption!

Why when you reduce the voltage decreases consumption?

The answer is simple: kW=U ( Volts) * I (Amps)*1000*PF

I = U / R- Ohm's law.

So when we reduce the Voltage that we reduce the strength of the current (Amps) , respectively we reduce consumption (kW)

For example in the area of Pattaya Beach Road, Walking Street in line voltage is greater than 240 volts. Therefore, many overpay for electricity. Often fail electrical equipment. Often burn out bulbs. We installed on our test unit test on Beach Road in the jewelry store Chada. Optimization of energy consumption has turned out more than 15%.