Introduction

Cardiac dysrhythmia, known as arrhythmia, is a medical condition where the rhythm of the heart is irregular, faster or slower than average.

The average healthy human adult has a heart rate of 60-70 heart beats per minute

Three forms of arrhythmia Tachycardia – When the heart rate exceeds 90 heart beats per

minute Bradycardia – When the heart rate is less than 60 heart beats per

minute Irregular – Inconsistent heart rhythm

Page 4: Detection of Arrhythmia

Significance of Problem

Each year in the United States, around 500,000 deaths occur from arrhythmia.

Arrhythmia In the atria results in inefficient flow of blood to the rest of the body. Can result in shortness of breath, blood clots and even a

stroke.

However, there can be a 15-20% decrease in the number of deaths if there is a correct and early diagnosis.

Page 5: Detection of Arrhythmia

Objective

The objective of this research is to analyze Electrocardiogram (ECG) signals to determine any onsets of arrhythmia.

The primary questions is whether the algorithm can accurately detect sinus tachycardia and bradycardia, along with any irregular heart rhythms.

Page 6: Detection of Arrhythmia

Study Population

The data was acquired from physionet’s online database;47 different ECG signals were obtained.

The study population had an age range from 23-89 years old, the average age of the patient was 63.

In the study, there were 21 males and 26 females. It is important that the people do not eat or drink anything

prior to the test as it could sway the results (ex caffeine). The data contains four different types of ECG’s: regular,

tachycardia, bradycardia and those who have an irregular heartbeat.

Page 7: Detection of Arrhythmia

Study Population

Each ECG downloaded contained an array of voltages (in mV).

A typical ECG lasts about (30-40seconds); the length of the acquired test was chosen to be one minute.

The signals were sampled at 360Hz.

Page 8: Detection of Arrhythmia

Methods

A modified Pan-Tompkins algorithm was used to analyze the ECG signals.

The original algorithm works by passing the signal through a low pass filter (to remove noise), a high pass filter (accentuate QRS peaks) and a derivative filter. It is then squared, passed through a moving average filter and then through a thresholding technique to detect R-peaks

Page 9: Detection of Arrhythmia

Methods (Modified Algorithm)

Bandpass – reduce noise and baseline drift Derivative filter – identifies QRS complex Squaring operation – increases frequencies Moving Average – signal is smoothed to highlight the

QRS complex Thresholding – Detects two types of peaks; the QRS

complex and T waves. Uses a search back technique to detect each R peak

Page 10: Detection of Arrhythmia

Detecting Irregularities

The algorithm will determine if a heartbeat is irregular1. Calculates time period differences between each peak2. Finds the difference of the two differences between peaks,

and compares to a tolerance level estimated to allow small number of premature contractions

3. If the QRS difference is greater than the tolerance level, then the program detects that segment as an irregularity.

4. The algorithm deems a ECG signal as irregular if it counts more than 8 irregularities

Page 11: Detection of Arrhythmia

Results

51%

13%

13%

21%

2%ECG Data ResultsNormal

TachycardiaBradycardiaIrregularVtach/VFib

Page 12: Detection of Arrhythmia

Normal ECGVo

ltage

(mV)

Index (N)

Page 13: Detection of Arrhythmia

Normal ECG

Volta

ge(m

V)

Index (N)

Page 14: Detection of Arrhythmia

Normal ECG 2Vo

ltage

(mV)

Index (N)

Page 15: Detection of Arrhythmia

Normal ECG 2

Volta

ge(m

V)

Index (N)

Page 16: Detection of Arrhythmia

Bradycardia Vo

ltage

(mV)

Index (N)

Page 17: Detection of Arrhythmia

Bradycardia

Volta

ge(m

V)

Index (N)

Page 18: Detection of Arrhythmia

Bradycardia 2Vo

ltage

(mV)

Index (N)

Page 19: Detection of Arrhythmia

Bradycardia 2

Volta

ge(m

V)

Index (N)

Page 20: Detection of Arrhythmia

TachycardiaVo

ltage

(mV)

Index (N)

Page 21: Detection of Arrhythmia

Tachycardia

Volta

ge(m

V)

Index (N)

Page 22: Detection of Arrhythmia

Tachycardia 2Vo

ltage

(mV)

Index (N)

Page 23: Detection of Arrhythmia

Tachycardia 2

Index (N)

Volta

ge(m

V)

Page 24: Detection of Arrhythmia

IrregularVo

ltage

(mV)

Index (N)

Page 25: Detection of Arrhythmia

Irregular

Index (N)

Volta

ge(m

V)

Page 26: Detection of Arrhythmia

Irregular 2Vo

ltage

(mV)

Index (N)

Page 27: Detection of Arrhythmia

Irregular 2

Index (N)

Volta

ge(m

V)

Page 28: Detection of Arrhythmia

Ventricular Tachycardia/FibrillationVo

ltage

(mV)

Index (N)

Page 29: Detection of Arrhythmia

Irregular

Index (N)

Volta

ge(m

V)

Ventricular Tachycardia/Fibrillation

Page 30: Detection of Arrhythmia

Discussion

Out of the 47 patients, 43 had a correct heart rate calculated by the algorithm (a 91.48% success rate).

Better than original algorithm (a 72.3% success rate) Problem with original algorithm is that it filtered the

signal so much that some of the peaks were reduced below the threshold which caused inaccurate calculation of heartbeats/minute.

It was important to make modifications so that the sampling and cut-off frequencies kept the QRS peaks intact.

Page 31: Detection of Arrhythmia

Future

The algorithm can be modified for future use to include detection of life threatening heart rhythms (ventricular fibrillation)

As a result there is no P wave, T wave and the QRS is elongated and occurs rapidly without a refractory period.

The algorithm can be modified to detect such occurrences by detecting absence of p waves. By detecting absence of p waves and measuring if the BPM is extremely high over small periods of time.

Page 32: Detection of Arrhythmia

Conclusion

The algorithm was successful in the primary objective of determining arrhythmic heart rhythm from the given ECG data.

The algorithm correctly identified sinus tachycardia and sinus bradycardia, while had a 91.48% overall success rate of identifying normal and arrhythmic heart rhythms.

Page 33: Detection of Arrhythmia

References[1] ‘Arrhythmia’, American Heart Association, 23-Oct-2014. [Online]. Available:

http://www.heart.org/HEARTORG/Conditions/Arrhythmia/Arrhythmia_UCM_002013_SubHomePage.jsp. [Accessed: 20-Nov-2014].[2] ‘Arrhythmia: A Patient Guide’, Health Central, 05-Sep-2001. [Online]. Available: http://www.healthcentral.com/heart-disease/patient-guide-

44628-6_1.html. [Accessed: 20-Nov-2014].[3] ‘Types of Arrhythmias’, Cleveland Clinic, Nov-2012. [Online]. Available: https://my.clevelandclinic.org/services/heart/disorders/arrhythmia/

types. [Accessed: 20-Nov-2014].[4] M. J. Janse and M. R. Rosen, ‘History of Arrhythmias’, Basis and Treatment of Cardiac Arrhythmias, 2006.[5] ‘What Is An Electrocardiogram (ECG)?’, The Internet Journal of Advanced Nursing Practice, vol. 4, 2000.[6] A. Davies and A. Scott, ‘Arrhythmias’, Starting to Read ECGs, 2015.[7] ‘What Is an Electrocardiogram?’, National Heart, Lung, and Blood Institution, 01-Oct-2010. [Online]. Available:

http://www.nhlbi.nih.gov/health/health-topics/topics/ekg. [Accessed: 20-Nov-2014].[8] ECG Database http://www.physionet.org/physiobank/database/mitdb/. [Accessed: 20-Nov-2014]

[9] H. Sedghamiz, 'Complete Pan Tompkins Implementation ECG QRS detector - File Exchange - MATLAB Central', Mathworks.com, 2014. [Online]. Available: http://www.mathworks.com/matlabcentral/fileexchange/45840-complete-pan-tompkins-implementation-ecg-qrs-detector. [Accessed: 08- Dec- 2014].

[10] C. Pavlatos, A. Dimopoulos, G. Manis and G. Papakonstantinou, Hardware Implementation of Pan & Tompkins QRS Detection Algorithm, 1st ed. Zografou, Athens: National Technical University of Athens, 2014, pp. 1-2 [Online]. Available: http://mule.cslab.ece.ntua.gr/docs/c8.pdf. [Accessed: 08- Dec- 2014]

[11] V. Afonso, ECG QRS Detection, 1st ed. 2014 [Online]. Available: http://www.masys.url.tw/AU/2014SP/BMSD-D/Text/BMSD-text-ECG_QRS_Detection.pdf. [Accessed: 08- Dec- 2014] [12] Pan.J, Tompkins. W.J,"A Real-Time QRS Detection Algorithm" Transactions On Biomedical Engineering, Vol. BME-32, No. 3, March 1985.