Authentic Instrument & Automation Pvt. Ltd.

Works & correspondence : 31, Indl Area, Jhotwara, Kamani Chawk,Jaipur-302013 (Raj.) INDIA.cell nos : 09314529100, 09352454200,09352454300, 09352454400,e-mail : [email protected] website : www.authenticinstruments.com

Page 2: blood bank centrifuge 12 bag

Authentic Instrument & Automation Pvt. Ltd.

Works & correspondence : 31, Indl Area, Jhotwara, Kamani Chawk,Jaipur-302013 (Raj.) INDIA.cell nos : 09314529100, 09352454200,09352454300, 09352454400,e-mail : [email protected] website : www.authenticinstruments.com

Sr nos Name of customer destination Sr nos Name of customer destination Remarks 1 Tapovan blood bank Shriganganagar, 10 Raj blood bank society Bharatpur 2 ram krishna blood bank Raipur ,cg 11 Bilasa blood bank Raipur Chhattisgarh 3 Govt medical college jalawar Kota,rajasthan 12 Bilasa blood bank Korba chhattisgarh 4 Sawsthya kalyan blood bank Jaipur rajasthan 13 Sk soni hospital (blood bank) Jaipur Rajasthan 5 Swastik blood bank Shriganganagar, 14 Kailsh hospital (blood bank) Behror,delhi road,Rajasthan 6 Spm hospital Kanpur , up 15 Bhabhria blood bank Bhawnagar gujrat 7 Mangalam blood bank Hissar, Haryana 16 Mullana medical college Ambala Haryana 8 Mahatma Gandhi medical college Jaipur rajathan 17 Agrasen blood bank Jaipur rajathan

Page 3: blood bank centrifuge 12 bag

Authentic Instrument & Automation Pvt. Ltd.

Works & correspondence : 31, Indl Area, Jhotwara, Kamani Chawk,Jaipur-302013 (Raj.) INDIA.cell nos : 09314529100, 09352454200,09352454300, 09352454400,e-mail : [email protected] website : www.authenticinstruments.com

9 Sevayatan blood bank Jaipur rajathan 18 Tara hospital Saharanpur up 19 Kolhapur blood bank Kolhapur,ms 20 mullana medical solan

Features : Fully Automatic with Touch Screen

Memory : Programmable Memory with tamper proof facility.

Swing Bucket Blood Bank Rotor : With Metal Buckets, wind shielded . Suitable adapters for 6,8,12 blood bags. Removable plastic cups to hold single/double/triple etc blood bags.

Centrifugal force : – 5000g ,RPM : 45000 rpm ,Maximum speed : Micro processor controlled rotor speed to within 10 rpm of set value. Acceleration /deceleration profiles available

Temperature Range : 40C to 300C LC: 0.5OC, Micro processor controlled rotor temperature within 10C regardless of the centrifuge speed.

Programmable Time : 0 – 99 minutes with minimum revolution of 0.1 minute,

Operation : Soft TOUCH SCREEN Operation – fully programmable

Digital Display : Digital Display of temperature, speed (rpm), time & g Value. No. of digit resolution etc., Screen : TOUCH SCREEN ,

Motor imbalance detection Automatic shut down of centrifuge of rotor load is out of balance with appropriate indicator.

Chamber Stainless Steel Chamber, easy to clean, corrosion resistant with provision of both drain and condensed water collection container.

MODEL

RC-6 RC-8 RC-12

CAPACITY 6 Standard Blood Bags 8 Standard Blood Bags 12 Standard Blood Bags EXTERNAL SIZE (W x D x H) 30x34x32 In Inch 30x34x32 In Inch 33x336x32 In Inch GROUND SPACE (W x D) 27x30 In Inch 27x30 In Inch 30x34 In Inch WEIGHT Approx 250 kg Approx 270 kg Approx 300 kg

Page 4: blood bank centrifuge 12 bag

Authentic Instrument & Automation Pvt. Ltd.

Works & correspondence : 31, Indl Area, Jhotwara, Kamani Chawk,Jaipur-302013 (Raj.) INDIA.cell nos : 09314529100, 09352454200,09352454300, 09352454400,e-mail : [email protected] website : www.authenticinstruments.com

Power Supply 220/240 Volts, 50 HZ Single Phase AC supply.

Suitability The equipment is suitable for operation from -10 to 400C at 90% RH. Electronic circuitry is tropicalised for this ambient condition ,

Voltage Corrector Copper wound single phase automatic line voltage corrector is required 4KVA .Electrical Safety Electronic safety device incorporated that will give audiovisual alarming case of power failure along with Low & High Voltage protector. Have security lock to prevent unintentional switch off and also unauthorized opening of the equipment.

Page 5: blood bank centrifuge 12 bag

Authentic Instrument & Automation Pvt. Ltd.

Works & correspondence : 31, Indl Area, Jhotwara, Kamani Chawk,Jaipur-302013 (Raj.) INDIA.cell nos : 09314529100, 09352454200,09352454300, 09352454400,e-mail : [email protected] website : www.authenticinstruments.com