INTRODUCING OUR NEW PRODUCT
SYSMEX XE 5000
A BRIEF INTRODUCTIONThe Sysmex XE-5000 Automated Hematology System utilizes the power of fluorescent flow cytometry and hydrodynamic focusing technologies.
Using a unique and advanced diode laser bench, Sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid samples.
Fluorescent technology and hydrodynamic focusing enable the XE-5000 to consistently differentiate normal WBC, RBC and PLT populations from abnormal populations, thereby decreasing the number of manual interventions.
The XE-5000 technology provides clinically relevant and reportable parameters.
Reportable parameters
43 parameters•CBC (14 parameters) –WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD,
RDW-CV, MPV, P-LCR, PDW, PCT•DIFF (12 parameters)–NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#, MONO#, EO#, BASO#, IG#•NRBC (2 parameters)–NRBC%, NRBC#,•RET (8 Parameters)–RET%, RET#, LFR, MFR, HFR, IRF, RET-He, IPF, (PLT-O)•Body Fluid (6 parameters)–WBC-BF, RBC-BF, MN%, MN#, PMN%, PMN#-HPC
SPECIFICATIONSPrinciples & Technologies Fluorescent Flow Cytometry:
WBC-Diff, IG, NRBC, RET, IRF, PLT-ORF-DC method:HPCDC-Sheath-Flow:PLT, RBC, HCTSLS-Method:Hgb
Linearity WBC: 0 – 440.00 x 103/µLRBC: 0 – 8.00 x 106/µLPLT: 0 – 5,000 x 103/µL
Body Fluid Linearity WBC-BF: 0.000 – 10.000 x 103/µLTC-BF: 0.000 – 10.000 x 103/µLRBC-BF: 0.000 – 5.000 x 106/µL
SPECIFICATIONS
Throughput Whole Blood Mode:150 samples/hr (max.)Body Fluid Mode:38 samples/hr (max.)
Sample Volumes 200μL / 130μL (manual closed mode/open mode)40μL for capillary mode
Data Storage(IPU: Information Processing Unit)
10,000 samples (incl. graphics)
Interfaces Sysmex WAM (HL7 & ASTM)
SPECIFICATIONS
Quality Control (Total QC Management)
Levey-Jennings control chartX-bar M fileOnline QC
Dimensions / Weight w x h x d [in] / [lbs]
Main unit: 27.8" x 35.9" x 28" / 178 lbs.Sampler: 22.8" x 7.7" x 14.8" / 26 lbs.IPU: 18" x 17.6" x 5.3" / 24 lbs.
Configurations Stand aloneSysmex HST-N™, Sysmex XE-AlphaN™
TARGET CUSTOMER
SUITABLE FOR LAB WHICH RECEIVES GREATER NUMBER OF SAMPLES PER DAY
SUITABLE FOR LAB WITH LESS STAFFS AS OUR ANALYZER IS AUTOMATED AND REQUIRES LESS MANPOWER.
XE-5000 ANALYSIS PRINCIPLE •Laser Flow Cytometry •ShealthFlow/Hydrodynamic
Focusing DC detection •RF/DC Detection Method •SLS Heamoglobin Method
FLUOROSCENCE FLOW CYTOMETRY
DC-HYDRODYNAMIC FOCUSING
XE-5OO0 MULTICHANNEL ANALYZER CHANNEL PRINCIPLE PARAMETERS
WBC/BASO Flow cytometry WBC,Baso #, BasoNRBC Flow cytometry NRBC #, NRBC %4 Diff Flow cytomtery Lymph# , Lymph%
Mono#, Mono%Eo# , Eo%Neut# , Neut%IG# , IG%
RET/PLT-O Flow cytometry RET#, RET%,PLT-O, HFR, MFR, LFR, IRFRET-He, IPF
IMI RF/DC-detection method
HPC#
HGB SLS-Method, photometry
HGBMCH,MCHC,MCV
RBC/PLT-Detector HDF DC-Detection method
RBC,HCT,PLT-I,RDW-SD, RDW-CV, PDW, MPV, P-LCR
REAGENT SYSTEM
OUTPUT
WHY SYSMEX XE-5000??
Integrated Sysmex SP-Series automated slide maker/stainer.
eMM software provides more specific flagging.
Measure body fluids. Advanced parameters
WHY SYSMEX XE-5000 ?
• HIGH THROUGHOUTPUT• NO NEED OF SAMPLE PREPARATION• SHORTENED TURN AROUND TIME• REDUCED SAMPLE VOLUME• LESS LIKEHOOD OF TRANSCRIPTIONAL ERRORS• PROVIDES 7 SCATTERGRAMS AND 2
HISTOGRAM FOR A BETTER ANALYSIS RANKED BY THIRD PARTY AS HIGHEST VENDOR
FOR RELIABILITY FOR 8 CONSECUTIVE YEARS IN A ROW*
CUSTOMER SERVICE
• In-time deliveries of reagents and consumable
• Instrument repair and maintenance including hot-line support
• Consultancy and management of complex laboratory installation projects
• Continuous post-market surveillance and feedback of market requirements as design input for new product development
• Management of customer events
YOUR COMPLETE CHOICE !!!