15
Chris Jeziorkowski

Central line errors

  • Upload
    acmcem

  • View
    274

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Central line errors

Chris Jeziorkowski

Page 2: Central line errors

Personal experience Complications overview Individual complications

Page 3: Central line errors
Page 4: Central line errors

385 Consecutive CVC placement over a 6 month period• 33% mechanical complication

22% failure to place 5% arterial puncture 4% catheter malposition 1% pneumothorax 1% subcutaneous hematoma <1% hemothorax <1% cardiac arrest

Page 5: Central line errors

Arrhythmias Vascular Injury Pulmonary Complications Guide Wires

Page 6: Central line errors

Ventricular dysrhythmias and bundle branch block • Cause by direct stimulation of endocardium• Prevented by limiting depth of guide wire

and catheter insertion to less that 16 cm

Page 7: Central line errors

Usually recognized by pulsatile blood flow and red appearance of blood• Can use US to confirm venous placement• Can get ABG and blood gas from your

sample to compare• Can transduce the pressure and observe

wave form

Page 8: Central line errors
Page 9: Central line errors

Femoral artery injury can be contained with direct pressure for 15 minutes

Page 10: Central line errors

Air on aspiration may mean you violated the pleural space

Always get confirmatory chest x ray for subclavian and IJ lines

Page 11: Central line errors
Page 12: Central line errors

Cases

Page 13: Central line errors

Inattention Inexperienced operator Inadequate supervision Overtired staff

Page 14: Central line errors

IR can remove guide wire

Page 15: Central line errors

Thoughts?