Upload
le-tu
View
207
Download
6
Tags:
Embed Size (px)
DESCRIPTION
RTR Catalogue tu bu rtr
Citation preview
Madrid, Espa naRTR Energia, S.L.
c/ Gavilanes, 11 Bis/ Pol.lnd. Pinto – Estacion/ 28320 Pinto (Madrid)Tel.:(+34) 916 916 612/ Fax : (+34) 916 912 257E-mail:[email protected]
Madrid, Espa naRTR Energia, S.L.
c/ Albatros, 30/ Pol.lnd. Pinto – Estacion/ 28320 Pinto (Madrid)Tel.:(+34) 916916 612/ Fax : (+34) 916 912 257E-mail:[email protected]
ChileRTR DNA Chile S.A.
La Estera nº 668 / Panamericana Norte, Km 17Loteo Valle Grande – Lampa, ChileTel.:(+56) 2 2328 44 00 / Fax : (+56) 2 2738 69 11E-mail:[email protected]
Vietnam Represented O�ceRTR Vietnam - Quanpham Co.,ltd
285 Dien Bien Phu, Ward 07 -district 03, Ho Chi Minh City - VietnamTel :+84 39304952 - 39302400 / Fax: +84 39304953E-mail: [email protected]
Capacitors Three phase capacitors with connector
MA/C/CE/TER Series 04
Reinforced three phase capacitors with connector
MA/C/CE/TER RTF Series 06
MA/C/CE/TER RCT Series 08
Three phase capacitors with connector
DW Series (New Compact Design) 10
Single phase capacitors with overpressure disconnection system
EA Series 12
Three-phase capacitors
Three-phase Harmonic Filters and Transformers
22
• General information of MV Capacitors 14
• Technical characteristics and dimensions of three-phase MV Capacitors 15
• Technical characteristics and dimensions of single-phase MV Capacitors 17
• Medium Voltage Capacitor Banks 21
Medium Voltage
Índex
Controllers Automatic reactive power controller PR-2D Series 24
Automatic reactive power controller PR-5D Series 25
Automatic reactive power controller PR-8D Series 26
04
MA/
C/CE
/TER Three phase capacitors with connector
MA/C/CE/TER Series230/400/415/440/480/525/690 V
Standards ..................................... IEC 60831-1/2 EN 60831-1/2
Capacitance tolerance ................... - 5% + 10%Frequency ...................................... 50Hz (60Hz upon request)Temperature range ........................ -25ºC + 55ºCDielectric losses ............................. ≤ 0.2 W/KVArTotal losses* .................................. ≤ 0.45 W/KVArMaximum over voltage .................. 1,1 x Un **Maximum over current ................... 1,5 x In Max. THD in voltage ....................... 2%Max. THD in current ........................ 25%Discharge resistance .................... IncorporatedConnection .................................... DeltaCasing ........................................... Aluminium canDisconnection system .................... OverpressureDielectric ........................................Voltage test between terminals ...... 2,15 x Un 2 sec.Voltage test terminals to case ............ 3 KV for 10 sec. ACTerminal type ................................. ConnectorInrush current ................................ Upto 200 x InProtection ...................................... IP 20, indoor mountingHumidity......................................... Max. 95%Expected life .................................. 120.000 Hrs (Temp. level C)Altitude........................................... Max. 2000 above sea level
Technical Characteristics
General DescriptionRTR Energía S.L. Power capacitors are manufactured with
-ne resin manufactured by RTR Energía, this resin provides an excellent heat dissipation properties. This series is enclosed in an aluminium can with overpressure disconnection system.
ApplicationsRTR Energía power capacitors are specially designed for reac -tive power factor correction using them individually or assem -bled into automatic capacitor banks series: Mini, Mural, Modu -lar, ST and Compact Series.
Overpressure disconnection systemIn order to avoid problems caused by overvoltage, harmonics, high temperatures, etc. RTR Energía S.L. power capacitors have been designed with an overpressure disconnection sys -tem. When the terminal cover expands, the internal connec -tions are interrupted and disconnecting the capacitor.
Dimensions
Overpressure disconnection system
DisconnectedConnected
DimensionsD x H (mm)
70 x 215
85 x 215
100 x 215
100 x 300
120 x 300
136 x 300
Cable sectionmm 2
2.5 mm 2
6 mm 2
10 mm 2
10 mm 2
25 mm 2
50 mm 2
regulation of voltage, higher values may cause damages in capacitor . EN 60831-1-1996(20.1)
*Without resistors
05
MA/C/CE/TER 50 Hz Series
* Other voltages upon request* 60 Hz upon request
MA/
C/CE
/TER
PowerKVAr
2.55
7.510
12.51520
VoltageV.c.a230 V230 V230 V230 V230 V230 V230 V
DimensionsD x H (mm)
70 x 21585 x 215
100 x 215100 x 300120 x 300120 x 300136 x 300
Code
C2300255TER0000C2300505TER0000C2300755TER0000C2301005TER0000C2301255TER0000C2301505TER0000C2302005TER0000
PowerKVAr
2,55
7.510
12.515202530354050
VoltageV.c.a400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V
DimensionsD x H (mm)
70 x 21570 x 21585 x 21585 x 215
100 x 215100 x 215100 x 300120 x 300120 x 300120 x 300136 x 300136 x 300
Code
C4000255TER0000C4000505TER0000C4000755TER0000C4001005TER0000C4001255TER0000C4001505TER0000C4002005TER0000C4002505TER0000C4003005TER0000C4003505TER0000C4004005TER0000C4005005TER0000
PowerKVAr
2,55
7.510
12.515202530354050
VoltageV.c.a415 V415 V415 V415 V415 V415 V415 V415 V415 V415 V415 V415 V
DimensionsD x H (mm)
70 x 21570 x 21585 x 21585 x 215
100 x 215100 x 215100 x 300120 x 300120 x 300120 x 300136 x 300136 x 300
Code
C4150255TER0000C4150505TER0000C4150755TER0000C4151005TER0000C4151255TER0000C4151505TER0000C4152005TER0000C4152505TER0000C4153005TER0000C4153505TER0000C4154005TER0000C4155005TER0000
PowerKVAr
2,55
7.510
12.515202530354050
VoltageV.c.a440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V
DimensionsD x H (mm)
70 x 21570 x 21585 x 21585 x 215
100 x 215100 x 215100 x 300100 x 300120 x 300120 x 300136 x 300136 x 300
Code
C4400255TER0000C4400505TER0000C4400755TER0000C4401005TER0000C4401255TER0000C4401505TER0000C4402005TER0000C4402505TER0000C4403005TER0000C4403505TER0000C4404005TER0000C4405005TER0000
PowerKVAr
2, 55
7. 510
12.515202530354050
Voltag eV.c.a480 V480 V480 V480 V480 V480 V480 V480 V480 V480 V480 V480 V
DimensionsD x H (mm)
70 x 21570 x 21585 x 21585 x 215
100 x 215100 x 215100 x 300120 x 300120 x 300120 x 300136 x 300136 x 300
Code
C4800255TER0000C4800505TER0000C4800755TER0000C4801005TER0000C4801255TER0000C4801505TER0000C4802005TER0000C4802505TER0000C4803005TER0000C4803505TER0000C4804005TER0000C4805005TER0000
PowerKVAr
2, 55
7. 510
12.515202530354050
Voltag eV.c.a525 V525 V525 V525 V525 V525 V525 V525 V525 V525 V525 V525 V
DimensionsD x H (mm)
70 x 21570 x 21585 x 21585 x 215
100 x 215100 x 215100 x 300120 x 300120 x 300120 x 300136 x 300136 x 300
Code
C5250255TER0000C5250505TER0000C5250755TER0000C5251005TER0000C5251255TER0000C5251505TER0000C5252005TER0000C5252505TER0000C5253005TER0000C5253505TER0000C5254005TER0000C5255005TER0000
PowerKVAr
2, 55
7. 510
12.515202530354050
Voltag eV.c.a690 V690 V690 V690 V690 V690 V690 V690 V690 V690 V 690 V 690 V
DimensionsD x H (mm)
70 x 21570 x 21585 x 21585 x 215
100 x 215100 x 215100 x 300120 x 300120 x 300120 x 300 136 x 300 136 x 300
Code
C6900255TER0000C6900505TER0000C6900755TER0000C6901005TER0000C6901255TER0000C6901505TER0000C6902005TER0000C6902505TER0000C6903005TER0000C6903505TER0000 C6904005TER0000 C6905005TER0000
06
Reinforced three phase capacitors with connector MA/C/CE/TER RTF Series230/400/440/460V, 50Hz
Standards ..................................... IEC 60831-1/2 EN 60831-1/2
Capacitance tolerance ................... - 5% + 10%Frequency ...................................... 50Hz (60Hz upon request)Temperature range ........................ -25ºC + 55ºCDielectric losses ............................. ≤ 0.2 W/KVArTotal losses* .................................. ≤ 0.45 W/KVArMaximum over voltage .................. 1,15 x UnMaximum over current ................... 1,5 x InMax. THD in voltage ....................... 3%Max. THD in current ........................ 30%Discharge resistance .................... IncorporatedConnection .................................... DeltaCasing ........................................... Aluminium canDisconnection system .................... OverpressureDielectric ........................................Voltage test between terminals ...... 2,15 x Un 2 sec.Voltage test terminals to case ............ 3 KV for 10 sec. ACTerminal type ................................. ConnectorInrush current ................................ Upto 200 x InProtection ...................................... IP 20, indoor mountingHumidity......................................... Max. 95%Expected life .................................. 130.000 Hrs (Temp. level D)Altitude........................................... Max. 2000 above sea level
Technical CharacteristicsGeneral DescriptionRTR Energía S.L. Power capacitors are manufactured with
-ne resin manufactured by RTR Energía, this resin provides an excellent heat dissipation properties. This series is enclosed in an aluminium can with overpressure disconnection system.
ApplicationsOversized to support over voltage and equipped with overpres -sure disconnection system. The capacitors are assembled in automatic capacitors banks series: Mini, Mural, Modular, ST and Compact Series.
Overpressure disconnection systemIn order to avoid problems caused by overvoltage, harmonics, high temperatures, etc. RTR Energía S.L. power capacitors have been designed with an overpressure disconnection sys -tem. When the terminal cover expands, the internal connec -tions are interrupted and disconnecting the capacitor.
Dimensions
Overpressure disconnection system
DisconnectedConnected
DimensionsD x H (mm)
70 x 215
85 x 215
100 x 215
100 x 300
120 x 300
136 x 300
Cable sectionmm 2
2.5
6
10
10
25
50
-lation of voltage, higher values may cause damages in capacitor. EN 60831-1-1996(20.1)
MA/
C/CE
/TER
RTF
*Without resistors
07
MA/C/CE/TER RTF 50 Hz Series
* Other voltages upon request* 60 Hz upon request
MA/
C/CE
/TER
RTF
Powe r
KVAr2.55
7.51015
Voltag e
V.c.a230 V230 V230 V230 V230 V
Dimensions
D x H (mm)70 x 21 5
100 x 215100 x 300120 x 300136 x 300
Code
Power Voltag e D imensions Code
Power Voltag e D imensions Code
Power Voltag e D imensions Code
C2300255R TFTER0C2300505R TFTER0C2300755R TFTER0C2301005R TFTER0C2301005R TFTER0
KVAr2,55
7.510
12.5152025303540
V.c.a400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V
D x H (mm)70 x 21 570 x 21 585 x 21 5
100 x 215100 x 215100 x 300100 x 300120 x 300120 x 300136 x 300136 x 300
C4000255R TFTER0C4000505R TFTER0C4000755R TFTER0C4001005R TFTER0C4001255R TFTER0C4001505R TFTER0C4002005R TFTER0C4002505R TFTER0C4003005R TFTER0C4003505R TFTER0 C4004005R TFTER0
KVAr2.55
7.510
12.5152025303540
V.c.a440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V
D x H (mm)70 x 21 570 x 21 585 x 21 5
100 x 215100 x 215100 x 300100 x 300120 x 300136 x 300136 x 300136 X 300
C4400255R TFTER0C4400505R TFTER0C4400755R TFTER0C4401005R TFTER0C4401255R TFTER0C4401505R TFTER0C4402005R TFTER0C4402505R TFTER0C4403005R TFTER0 C4403505R TFTER0 C4404005R TFTER0
KVAr2.55
7.510
12.5152025303540
V.c.a460 V460 V460 V460 V460 V460 V460 V460 V460 V460 V460 V
D x H (mm)70 x 21 570 x 21 585 x 21 5
100 x 215100 x 215100 x 300100 x 300120 x 300136 x 300136 x 300136 X 300
C4600255R TFTER0C4600505R TFTER0C4600755R TFTER0C4601005R TFTER0C4601255R TFTER0C4601505R TFTER0C4602005R TFTER0C4602505R TFTER0C4603005R TFTER0 C4603505R TFTER0 C4604005R TFTER0
08
Three phase capacitors with connector for harmonics filter applications MA/C/CE/TER RCT Series230/400/440/480V, 50Hz
General DescriptionRTR Energía S.L. Power capacitors are manufactured with low
-
manufactured by RTR Energía, this resin provides an excellent heat dissipation properties. This series is enclosed in an alumi -nium can with overpressure disconnection system.
Applications Capacitors specially designed to install with 189 Hz (other fre -
power capacitors are assembled into Arm´s series Automatic capacitor bank.
Overpressure disconnection systemIn order to avoid problems caused by overvoltage, harmonics, high temperatures, etc. RTR Energía S.L. power capacitors have been designed with an overpressure disconnection sys -tem. When the terminal cover expands, the internal connec -tions are interrupted and disconnecting the capacitor.
Dimensions
Overpressure disconnection system
DisconnectedConnected
-lation of voltage, higher values may cause damages in capacitor. EN 60831-1-1996(20.1)
MA/
C/CE
/TER
RCT
Standard ....................................... EN 6 0831-1/2Capacitance tolerance ................... - 5% + 10%Frequency ...................................... 50Hz (60Hz upon request)Temperature range ........................ -25ºC + 55ºCDielectric losses ............................. ≤ 0.2 W/KVArTotal losses* .................................. ≤ 0.45 W/KVArMaximum over voltage .................. 1,15 x UnMaximum over current ................... 1,5 x InMax. THD in voltage .......................
harmonicsMax. THD in current ........................ 30%Discharge resistance .................... IncorporatedConnection .................................... DeltaCasing ........................................... Aluminium canDisconnection system .................... OverpressureDielectric ........................................Voltage test between terminals ...... 2,15 x Un 2 sec.Voltage test terminals to case ............ 3 KV for 10 sec. ACTerminal type ................................. ConnectorInrush current ................................ Upto 200 x InProtection ...................................... IP 20, indoor mountingHumidity......................................... Max. 95%Altitude........................................... Max. 2000 above sea level
Technical Characteristics
DimensionsD x H (mm)
70 x 215
85 x 215
100 x 215
100 x 300
120 x 300
136 x 300
Cable sectionmm 2
2.5
6
10
10
25
50
*Without resistors
09
MA/C/CE/TER RCT 50 Hz Series
* Other voltages upon request* 60 Hz upon request
MA/
C/CE
/TER
RCT
Powe rKVAr
2.55
7.510
12.5152025
VoltageV.c.a230 V230 V230 V230 V230 V230 v230 V230 V
DimensionsD x H (mm)
70 x 21 580 x 21 5
100 x 215100 x 300100 x 300120 x 300136 x 300136 x 300
Code
Power Voltage Dimensions Code
Power Voltage Dimensions Code
Power Voltage Dimensions Code
C2300255TER0RCTC2300505TER0RCTC2300755TER0RCTC2301005TER0RCTC2301005TER0RCTC2301505TER0RCTC2302005TER0RCTC2302505TER0RCT
KVAr2,55
7.510
12.5152025303540
V.c.a400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V400 V
D x H (mm)70 x 21 570 x 21 585 x 21 5
100 x 215100 x 215100 x 300100 x 300120 x 300120 x 300136 x 300136 x 300
C4000255TER0RCTC4000505TER0RCTC4000755TER0RCTC4001005TER0RCTC4001255TER0RCTC4001505TER0RCTC4002005TER0RCTC4002505TER0RCTC4003005TER0RCTC4003505TER0RCT C4004005TER0RCT
KVAr2.55
7.510
12.5152025303540
V.c.a440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V440 V
D x H (mm)70 x 21 570 x 21 585 x 21 5
100 x 215100 x 215100 x 300100 x 300120 x 300120 x 300136 x 300136 X 300
C4400255TER0RCTC4400505TER0RCTC4400755TER0RCTC4401005TER0RCTC4401255TER0RCTC4401505TER0RCTC4402005TER0RCTC4402505TER0RCTC4403005TER0RCT C4403505TER0RCT C4404005TER0RCT
KVAr2.55
7.510
12.5152025303540
V.c.a480 V480 V480 V480 V480 V480 V480 V480 V480 V480 V480 V
D x H (mm)70 x 21 570 x 21 585 x 21 5
100 x 215100 x 215100 x 300100 x 300120 x 300120 x 300136 x 300136 X 300
C4800255TER0RCTC4800505TER0RCTC4800755TER0RCTC4801005TER0RCTC4801255TER0RCTC4801505TER0RCTC4802005TER0RCTC4802505TER0RCTC4803005TER0RCT C4803505TER0RCT C4804005TER0RCT
10
DW
Three phase capacitors with connectorDW Series New Compact Design230/400/415/440/480/525 V
Standard ....................................... IEC 60831-1/2 EN 60831-1/2
Capacitance tolerance ................... - 5% + 10%Frequency ...................................... 50Hz (60Hz upon request)Temperature range ........................ -25ºC + 55ºCDielectric losses ............................. ≤ 0.2 W/KVArTotal losses* .................................. ≤ 0.45 W/KVArMaximum over voltage .................. 1,1 x Un **Maximum over current ................... 1,5 x InMax. THD in voltage ....................... 2%Max. THD in current ........................ 25%Discharge resistance .................... IncorporatedConnection .................................... DeltaCasing ........................................... Aluminium canDisconnection system .................... OverpressureDielectric ........................................ Metallized.......................................................Voltage test between terminals ...... 2,15 x Un 2 sec.Voltage test terminals to case ............ 3 KV for 10 sec. ACTerminal type ................................. ConnectorInrush current ................................ Upto 200 x InProtection ...................................... IP 20, indoor mountingHumidity......................................... Max. 95%Expected life .................................. 100.000 Hrs (Temp. level C)Altitude........................................... Max. 2000 above sea level
Technical Characteristics
General DescriptionRTR Energía S.L. Power capacitors are manufactured with
-ne resin manufactured by RTR Energía, this resin provides an excellent heat dissipation properties. This series is enclosed in an aluminium can with overpressure disconnection system.
ApplicationsRTR Energía power capacitors are specially designed for reac -tive power factor correction using them individually or assem -bled into automatic capacitor banks series: Mini, Mural, Modu -lar, ST and Compact Series.
Overpressure disconnection system In order to avoid problems caused by overvoltage, harmonics, high temperatures, etc. RTR Energía S.L. power capacitors have been designed with an overpressure disconnection sys -tem. When the terminal cover expands, the internal connec -tions are interrupted and disconnecting the capacitor.
Dimensions
Overpressure disconnection system
DisconnectedConnected
DimensionsD x H (mm)
70 x 215
85 x 215
100 x 215
120 x 215
136 x 215
Cable sectionmm 2
4
6
10
16
25
regulation of voltage, higher values may cause damages in capacitor . EN 60831-1-1996(20.1)
*Without resistors
INNOVATION
PATENT P ENDING
11
50 Hz DW Series
* Other voltages upon request* 60 Hz upon request
PowerKVAr
57.510
12.515
VoltageV.c.a230 V230 V230 V230 V230 V
DimensionsD x H (mm)85 x 215
100 x 21 5120 x 21 5136 x 21 5136 x 21 5
Code
D2300505TER000 0D2300755TER000 0D2301005TER000 0D2301255TER000 0D2301505TER000 0
KVAr10
12.51520253035
V.c.a415 V415 V415 V415 V415 V415 V415 V
D x H (mm)85 x 21585 x 215
100 x 21 5120 x 21 5120 x 21 5136 x 21 5136 x 21 5
D4151005TER000 0D4151255TER000 0D4151505TER000 0D4152005TER000 0D4152505TER000 0D4153005TER000 0D4153505TER000 0
KVAr10
12.51520253035
V.c.a400 V400 V400 V400 V400 V400 V400 V
D x H (mm)85 x 21585 x 215
100 x 21 5120 x 21 5120 x 21 5136 x 21 5136 x 21 5
D4001005TER000 0D4001255TER000 0D4001505TER000 0D4002005TER000 0D4002505TER000 0D4003005TER000 0D4003505TER000 0
Power Voltage Dimensions Code
Power Voltage Dimensions Code
KVAr10
12.5152025303540
V.c.a440 V440 V440 V440 V440 V440 V440 V440 V
D x H (mm)70 x 21585 x 21585 x 215
100 x 21 5120 x 21 5120 x 21 5136 x 21 5136 x 21 5
D4401005TER000 0D4401255TER000 0D4401505TER000 0D4402005TER000 0D4402505TER000 0D4403005TER000 0D4403505TER000 0D4404005TER000 0
Power Voltage Dimensions Code
PowerKVAr
1012. 51520253035
VoltageV.c.a480 V480 V480 V480 V480 V480 V480 V
DimensionsD x H (mm)
85 x 21585 x 215
100 x 215120 x 215120 x 215136 x 215136 x 215
Code
D4801005TER0000D4801255TER0000D4801505TER0000D4802005TER0000D4802505TER0000D4803005TER0000D4803505TER0000
Power Voltage Dimensions CodeKVAr
1012. 51520253035
V.c.a525 V525 V525 V525 V525 V525 V525 V
D x H (mm)85 x 21585 x 215
100 x 215120 x 215120 x 215136 x 215136 x 215
C5251005TER0000C5251255TER0000C5251505TER0000C5252005TER0000C5252505TER0000C5253005TER0000C5253505TER0000
DW
12
Single phase capacitors with overpressure disconnection systemEA Series230/400/415/440/480V, 50Hz
General DescriptionRTR Energía S.L. Power capacitors are manufactured with low
polyurethane resin manufactured by RTR Energía, this resin provides an excellent heat dissipation properties. This series is enclosed in an aluminium can with overpressure disconnection system.
ApplicationsRTR Energía power capacitors are specially designed for reac -tive power factor correction using them individually or assem -bled into automatic capacitor banks.
Overpressure disconnection systemIn order to avoid problems caused by overvoltage, harmonics, high temperatures, etc. RTR Energía S.L. power capacitors have been designed with an overpressure disconnection sys -tem. When the terminal cover expands, the internal connec -tions are interrupted and disconnecting the capacitor.
Dimensions
Overpressure disconnection system
DisconnectedConnected
DimensionsD x H (mm)
70 x 140
Terminal�
FAD 6,3
regulation of voltage, higher values may cause damages in capacitor . EN 60831-1-1996(20.1)
EA
Standard ....................................... EN 60831-1/2Capacitance tolerance ................... - 5% + 10%Frequency ...................................... 50Hz (60Hz upon request)Temperature range ........................ -25ºC + 55ºCDielectric losses ............................. ≤ 0.2 W/KVArTotal losses* .................................. ≤ 0.45 W/KVArMaximum over voltage .................. 1,1 x Un **Maximum over current ................... 1,5 x InMax. THD in voltage ....................... 2%Max. THD in current ........................ 25%Discharge resistance .................... IncorporatedConnection .................................... Single-phaseTerminals ....................................... 2x6.3 QcCasing ........................................... Aluminium canDisconnection system .................... OverpressureDielectric ........................................ Metallized.......................................................Voltage test between terminals ...... 2,15 x Un 2 sec.Voltage test terminals to case ............ 3 KV for 10 sec. ACTerminal cover ............................... Plastic cover PA-6
Technical Characteristics
*Without resistors
13
EA 50 Hz Series
* Other voltages upon request* 60 Hz upon request
EAPowe rKVAr
0,831,672,50
VoltageV.c.a230 V230 V230 V
DimensionsD x H (mm)
70 x 14 070 x 14 070 x 14 0
Code
Power Voltage Dimensions Code
Power Voltage Dimensions Code
Power Voltage Dimensions Code
Power Voltage Dimensions Code
EA023008350000 0EA023016750000 0EA023025050000 0
KVAr0,831,672,503,334,17
V.c.a400 V400 V400 V400 V400 V
D x H (mm)70 x 14 070 x 14 070 x 14 070 x 14 070 x 14 0
EA040008350000 0EA040016750000 0EA040025050000 0EA040033350000 0EA040041750000 0
KVAr0,831,672,503,334,17
V.c.a415 V415 V415 V415 V415 V
D x H (mm)70 x 14 070 x 14 070 x 14 070 x 14 070 x 14 0
EA041508350000 0EA041516750000 0EA041525050000 0EA041533350000 0EA041541750000 0
KVAr0,831,672,503,334,17
V.c.a440 V440 V440 V440 V440 V
D x H (mm)70 x 14 070 x 14 070 x 14 070 x 14 070 x 14 0
EA044008350000 0EA044016750000 0EA044025050000 0EA044033350000 0EA044041750000 0
KVAr0,831,672,503,334,17
V.c.a480 V480 V480 V480 V480 V
D x H (mm)70 x 14 070 x 14 070 x 14 070 x 14 070 x 14 0
EA048008350000 0EA048016750000 0EA048025050000 0EA048033350000 0EA048041750000 0
14
MED
IUM
VO
LTAG
E
1. General information for MV capacitors
1.1 Total film dielectric
RTR Capacitors have a dielectric constituted in general by
purity. This construction, instead of which it uses only two
other manufacturers, confers to RTR Capacitors greater secu -rity of operation and greater life utility. The rough of both faces of polypropylene is a condition indispensable for the complete
the stability of the capacitor in the long term.
1.2 Impregnating biodegradable
RTR Capacitors use exclusive impregnating the nonchlorina -ted MDBT, developed for the most demanding applications by
point, great capacity of gas absorption derived from the internal electrical unloadings, and total environmental compatibility (biodegradable).
1.3 Construction with folio extended and wild fold
RTR Capacitors is constituted by elementary units, each one of them consisting of aluminum folio windings of high purity
anticrown that confers to the condenser a tension of insepción ofpartial unloadings superior to 50% of the nominal value. The laminae are welded to each other and with the next coils by means of special alloys of great adhesion and low point of fusion. This way the use of “abatis”, characteristic of the previous designs is avoided.
1.4 Under stress
RTR Energía S.L. uses conservative criteria of design that imply the application of dielectric e�orts (kV/ mm) relatively low on the materials. Like consequence, the capacitors are of dimensions somewhat greater than those of other marks, with an expec -tation of greater life utility.
1.5 Inner fuses
RTR Energía S.L. incorporates to a great part of their range of MV. capacitors (specially for the greater powers) with the option of individual inner fuses by coil, of new design. Such they allow to isolate the possible failure of anyone of the elements of the capacitor and other elements can still work in normal condition. The fuses are separated to each other, so that it is impossible that the performance of one of them causes the catuación of the fuse next to. In addition, the condensers with internal fuses allow simpler, light and economic constructions.
1.6 Dielectric low losses
The characteristics of their design, the rigorous selection of the manufacture materials and the artisan care put in their construc -tion and process give like result capacitors of low losses, which is translated in smaller this form and operating temperatures, a greater life utility.
15
MED
IUM
VO
LTAG
E
2. Tecnical characteristics and dimensions for three-phase capacitors
Standard .............................................................................................................................. IEC 871-1/4 Voltage test terminal to terminal .......................................................................................... 1 - 7,2 kV Frequency ........................................................................................................................... 50 - 60 Hz Losses ................................................................................................................................ <0.15 W/KVAr Temperature ....................................................................................................................... -5+50ºC Dielectric liquid ................................................................................................................... MDBT Nonchlorinated Residual Voltage ................................................................................................................ 10% Un later 5 min. Dielectric ............................................................................................................................ Polypropylene Fuses .................................................................................................................................. Optional Use ..................................................................................................................................... Indoor-Inclemency Altitude ............................................................................................................................... 1000 m s.n.m. Maximum over voltage. ...................................................................................................... 1.1 x Un Maximum over current ....................................................................................................... 1.3 x In Tolerance ............................................................................................................................. -5 + 15% Vltage test ........................................................................................................................... 4,3 x Un (10 sec
2.1 Aproximated dimensions
Notes:
1. In these tables the equipments of use have been included mas commonly nevertheless they can be made for other voltages, frequencies, etc.
3. Also is possible the construction of single-phase capacitors with one point or two isolated points.
4. The dimensions and others characteristics are subject to changes without previous notice
16
MED
IUM
VO
LTAG
E2.2 Range from 1 to 1,2 kV
2.3 Range from 2 to 3,6 kV
a 50 Hz10152550
100
a 50 Hz255075
83.3100150167200250300
a 60 Hz12183060
120
a 60 Hz306090
100120180200240300360
Power (kVAr)
Power (kVAr)
Dimensions
Dimensions
A (mm)200200200260450
A (mm)200200300300320500500580660680
B (mm)135135135135135
B (mm)135135135135135135135135135160
C (mm)130130130230230
C (mm)130130230230230230230230230230
WeightKg.1516172032
WeightKg.15172122253535404955
BIL = 25 kVwithout terminal cover
BIL = 40 kVwithout terminal cover
BIL = 25 kVwith terminal cover
BIL = 40 kVwith terminal cover
17
MED
IUM
VO
LTAG
E
2.4 Range from 4 to 7,2 kV
a 50 Hz255075
83.3100150167200250300
a 60 Hz306090
100120180200240300360
Power (kVAr) DimensionsA (mm)
260260320320360460500600700720
B (mm)135135135135135135135135135160
C (mm)130130230230230230230230230230
WeightKg.16182223263636415056
BIL = 60 kVwithout terminal cover
3. Technical characteristics and dimensions for single-phase capacitors Standard .............................................................................................................................. IEC 871-1/4 Frequency ........................................................................................................................... 50 - 60 Hz Losses ................................................................................................................................ <0.15 W/KVAr Temperature ....................................................................................................................... -5+50ºC Dielectric liquid ................................................................................................................... MDBT Nonchlorinated Residual Voltage ................................................................................................................ 10% Un later 5 min. Dielectric ............................................................................................................................ Polypropylene Fuses .................................................................................................................................. Optional Use ..................................................................................................................................... Indoor - Inclemency Altitude ............................................................................................................................... 1000 m s.n.m. Maximum over voltage ....................................................................................................... 1.1 x Un Maximum over current ....................................................................................................... 1.3 x In Tolerance ............................................................................................................................. -5 + 15% Voltage test terminal to terminal .......................................................................................... 4,3 x Un (10 sec)
3.1 Aproximated dimensions
Notes:
1. In these tables the equipments of use have been included mas commonly nevertheless they can be made for other voltages, frequencies, etc.
3. Also is possible the construction of single-phase capacitors with one point or two isolated points. 4. The dimensions and others characteristics are subject to changes without previous notice
18
MED
IUM
VO
LTAG
E3.2 Range from 6 to 36 kV
a 50 Hz3350
83.3100150167200250300333400500
a 60 Hz4060
100120180200240300360400480600
Power (kVAr) DimensionsA (mm)
200200320320450500580660720720860
1080
B (mm)135135135135135135135135160160160160
C (mm)130130230230230230230230230230230230
WeightKg.151722253535404955596779
BIL = 95 y 110 kV2 stud terminals
BIL = 125 kV2 stud terminals
BIL = 95 y 110 kV1 stud terminal
BIL = 125 kV1 stud terminal
19
MED
IUM
VO
LTAG
E
BIL = 150 kV2 stud terminals
BIL = 150 kV1 stud terminal
4. Capacitors banks of medium voltage
4.1 Fixed banks for medium voltage overhead distribution lines
Simple, compact, low cost, maintenance-free capacitor banks for pole mounting on overhead distribution feeders. They provide voltage level support and loss reduction, in -
creasing power quality o�ered to costumers.
Reactive Power Range: from 75 to 1500 kVAr (50Hz); from 90 to 1800 kVAr (60 Hz); and voltage level from,3.6 to 36 kV.
20
MED
IUM
VO
LTAG
E
4.2 Automatic capacitor banks for medium voltage overhead distribution lines
-trol strategies based either on time of day, voltage level, VAR demand, temperature or a combination of them. Micropro -cessor-based controls with metering, event recording, annual programming and remote supervision capacity. Capacitor switching by means of economical oil switches or maintenance-free vacuum switches with dry, solid foam insulation.
Reactive Power Range: from 75 to 1500 kVAr (50Hz); from 90 to 1800 kVAr (60 Hz); and voltage level from,3.6 to 36 kV.
Reactive Power Range: from 75 to 20 kVAr (50Hz); from 90 to 24 kVAr (60 Hz); and voltage level from,3.6 to 36 kV.
Reactive Power Range: from 75 to 1500 kVAr (50Hz); from 90 to 1800 kVAr (60 Hz); and voltage level from,3.6 to 36 kV.
4.3 Fixed, open type medium voltage capacitor banks for industrial installations and small power substations
When the capacitors are installed at the customer’s installa -tion, they provide low power factor penalty reduction or elimi -nation. Floor-or platformmounted banks of reduced fooftprint. Capacitors connected in simple or double wye with unbalance protection. Various sectionalizing and protection schemes available.
4.4 Automatic, open type medium voltage capacitor banks for large industrial ins -tallations and power substations
Control strategies based either on time of day, voltage level, VAR demand, temperature or combination of them. Single- or multista -ge banks, each stage provided with independent switching, protection and inrush current limiting reactors. O�-the-shelf or PLC-based, open-architecture controls. Special control options: Zero-Voltage-Crossing (ZVC) of switches, automatic tripping of bank upon loss of voltage, time-delayed bank reconnection after power restoring.
21
MED
IUM
VO
LTAG
E
Reactive Power Range: From 1 to 100 MVAr (50Hz); From 1.2 to 120 MVAr (60 Hz); and voltage level from 36 kV to 145 kV.
Reactive Power Range: from 1 to 100 MVAr (50Hz); from 1.2 to 120 MVAr (60 Hz); and voltage level from 36 kV to 145 kV.
4.5 High voltage capacitor banks for large power substations
They provide large amounts of reactive power to the system. All bank components are designed to withstand large short-circuit currents. Capacitors are connected in simple wye, double wye or bridge connection.
4.6 Metal enclosed capacitor banks
Metal-enclosedcapacitormodules,factory-assembled, ready to install in indoor or outdoor locations. Capacitor switching with vacuum contactors, vacuum switches or vacuum circuit breakers.
Reactive Power Range: from 50 kVAr to 6 MVAr (50Hz); from 60 kVAr to 7.2 MVAr (60 Hz); and voltage level from 2.3 kV to 15 kV.
4.7 Fixed capacitor Banks for the mining and oil industries
They are used to supply reactive power to internal power distribu -
well pumps, oil-pumping stations, etc. Sturdy design to withsta nd the harshest environmental conditions without maintenance. No
22
Three-phase harmonic filters
Complince standard .............................. IEC-60289;IEC-076Tolerance “L” .......................................... 3%Permisible overload ............................... 1,07 x InLinearity Inductance .............................. 1,60 x InHeat insulation ....................................... Clase F (155ºC)Thermal protection ................................. 90ºCRoom temperature ................................. 45ºCProof stress ........................................... 4KVProtection degree .................................. IP-00Detuning factor (p%) .............................. 7% - 14%
Technical Characteristics
Constructive Characteristics -
netic plates, permanent regime class F (155ºC) copper con -ductor and 90ºC thermal protection relay.
are separated among them, improving thermal dissipation.
Standard surge factor is 7% and 14% with resonance fre -quency 189 Hz and 134 Hz for 50 Hz networks.
With this standard values in three phase networks and ba -lanced loads, the 5th (250 Hz) harmonic and higher resp -nant phenomenons are eliminated avoiding resonance bet -ween inductive impedance and three phase capacitors for power factor correction and preventing network capacitors and capacitor banks for overloads.
PowerKVAr
2,55
1012,51520253040
PowerKVAr
2,55
1012,51520253040
InductancemH5,072,531,271,010,840,630,510,420,32
InductancemH
10,905,452,732,181,821,361,090,910,68
CapacitanceµF
3x46,633x93,27
3x186,533x233,173x279,803x373,073x466,333x559,603x746,13
CapacitanceµF
3x43,123x86,25
3x172,493x215,623x258,743x344,993x431,233x517,483x689,97
CurrentA
6,2812,5525,1031,3837,6550,2062,7675,31
100,41
CurrentA
6,2812,5525,1031,3837,6550,2062,7675,31
100,41
Code
RTF23000251895RTF23000501895RTF23001001895RTF23001251895RTF23001501895RTF23002001895RTF23002501895RTF23003001895RTF23004001895
Code
RTF23000251345RTF23000501345RTF23001001345RTF23001251345RTF23001501345RTF23002001345RTF23002501345RTF23003001345RTF23004001345
Rated Voltage: 230 V; Nominal Frequecy: 50 Hz. Resonance fequency: 189 Hz; Detuning factor: 7 %
Rated Voltage: 230 V; Nominal Frequecy: 50 Hz. Resonance fequency: 134 Hz; Detuning factor: 14 %
REA
CTA
NCE
S A
ND
TR
AN
SFO
RMER
S
Copper winding
23
PowerKVAr
2,55
1012,5152025304050607080
100
PowerKVAr
2,55
1012,5152025304050607080
100
PowerKVAr
2,55
1012,5152025304050607080
100
PowerKVAr
2,55
1012,5152025304050607080
100
InductancemH
15,337,673,833,072,561,921,531,280,960,770,640,550,480,38
InductancemH
32,9816,498,256,605,504,123,302,752,061,651,371,181,030,82
InductancemH
18,559,284,643,713,092,321,861,551,160,930,770,660,580,46
InductancemH
39,9119,959,987,986,654,993,993,332,492,001,661,431,251,00
CapacitanceµF
3x15,423x30,843x61,673x77,093x92,51
3x123,353x154,183x185,023x246,693x308,363x370,043x431,713x493,383x616,73
CapacitanceµF
3x14,263x28,523x57,033x71,293x85,55
3x114,063x142,583x171,093x228,123x285,153x342,183x399,213x456,243x570,31
CapacitanceµF
3x12,743x25,483x50,973x63,713x76,45
3x101,943x127,423x152,913x203,883x254,853x305,813x356,783x407,753x509,69
CapacitanceµF
3x11,783x23,573x47,133x58,923x70,703x94,27
3x117,833x141,403x188,533x235,663x282,803x329,933x377,063x471,33
CurrentA
3,617,22
14,4318,0421,6528,8736,0843,3057,7472,1786,60
101,04115,47144,34
CurrentA
3,617,22
14,4318,0421,6528,8736,0843,3057,7472,1786,60
101,04115,47144,34
CurrentA
3,286,56
13,1216,4019,6826,2432,8039,3652,4965,6178,7391,85
104,97131,22
CurrentA
3,286,56
13,1216,4019,6826,2432,8039,3652,4965,6178,7391,85
104,97131,22
Code
RTF40000251895RTF40000501895RTF40001001895RTF40001251895RTF40001501895RTF40002001895RTF40002501895RTF40003001895RTF40004001895RTF40005001895RTF40006001895RTF40007001895RTF40008001895RTF40010001895
Code
RTF40000251345RTF40000501345RTF40001001345RTF40001251345RTF40001501345RTF40002001345RTF40002501345RTF40003001345RTF40004001345RTF40005001345RTF40006001345RTF40007001345RTF40008001345RTF40010001345
Code
RTF44000251895RTF44000501895RTF44001001895RTF44001251895RTF44001501895RTF44002001895RTF44002501895RTF44003001895RTF44004401895RTF44005001895RTF44006001895RTF44007001895RTF44008001895RTF44010001895
Code
RTF44000251345RTF44000501345RTF44001001345RTF44001251345RTF44001501345RTF44002001345RTF44002501345RTF44003001345RTF44004401345RTF44005001345RTF44006001345RTF44007001345RTF44008001345RTF44010001345
Rated Voltage: 400 V; Nominal Frequecy: 50 Hz. Resonance fequency: 189 Hz; Detuning factor: 7 %
Rated Voltage: 400 V; Nominal Frequecy: 50 Hz. Resonance fequency: 134 Hz; Detuning factor: 14 %
Rated Voltage: 440 V; Nominal Frequecy: 50 Hz. Resonance fequency: 189 Hz; Detuning factor: 7 %
Rated Voltage: 440 V; Nominal Frequecy: 50 Hz. Resonance fequency: 134 Hz; Detuning factor: 14 %
REA
CTA
NCE
S A
ND
TR
AN
SFO
RMER
S
24
Voltage supply ................................... 230 VVoltage measurement ........................ 110-690 VFrequency .......................................... 50-60 HzCurrent Transformer .......................... x/5 AC/K setting ......................................... Automatic ajustement, ........................................................... allows re-adjustements ........................................................... between 0,05 and 0,95Cos j setting ..................................... 0.85 IND a 0.95 CAPCos j indicator .................................. DigitalTendendy indicator ............................ luminous indicatorCapacitor status ................................. luminous indicatorMeasurement system ........................ A1 - Automatic, ........................................................... A2-Semiautomatic,........................................................... A3 - ManualVisualization ...................................... Secondary signal T.I.Connect time ..................................... 10 to 20 sec.Programing ........................................ 1:1:1; 1:2:2; 1:2:4; ........................................................... 1:1:2; 1:1:2:2:4Manual connection pulsers ................ 4 segNumber of steps ................................ 3,6 and 12
Front panell ............................................ 144 x 144 mm
Mounting aperture ................................. 138 x 138 mm
Depth ..................................................... 95 mm
Mounting ................................................ Brackets
Real connection ..................................... Plug-in connector
Protection .............................................. IP 41
Temperature .......................................... -10 + 60 ºC
Weight ................................................... 1,25 Kg
Technical Characteristics Mechanical Characteristics
CodeREG03DPR2500000REG06DPR2500000 REG12DPR2500000
Tipo PR-2DPR-2D 3 StepsPR-2D 6 Steps
PR-2D 12 StepsPR-2D 144 x 144
PR-2
DAutomatic reactive power controllerPR-2D Series
Dimensions
25
Voltage supply ....................................... 380...415 VacFrequency .............................................. 50-60 HzCos j ..................................................... 0.8 IND...0.80 CAPCos j indicator ..................................... DigitalTendendy indicator ................................ Luminous indicatorCapacitor status ..................................... Luminous indicatorConnect time .......................................... 5...240 seg.Programing ............................................ 1:1:1; 1:2:2; 1:2:4:4; ............................................................... 1:2:4:8;Number of steps .................................... 5, 7
Front panell ............................................ 96 x 96 mm
Mounting aperture ................................. 91 x 91 mm
Depth ..................................................... 65 mm
Protection .............................................. IP 54
Mounting ................................................ Brackets
Real connection ..................................... Plug-in connector
Temperature .......................................... -20 + 60 ºC
Weight ................................................... 440...460 g
Technical Characteristics Mechanical Characteristics
CodeREG05DPR5500000REG07DPR5500000
Tipo PR-5DPR-5D 5 StepsPR-5D 7 StepsPR-5D 96 x 96
PR-5
D
Automatic reactive power controllerPR-5D Series
Dimensions
26
Supply voltage ......................................... (phase-neutral) 220 VACRang of operation .............................. (0.8-1.1) x UnFrequency .......................................... 50HzPower consumption ........................... <1 VAContact’s current ............................... Máx. 3 A / 240 VCACurrent meaurement rang .................... 0.1 - 6 A CADisplay rang ....................................... 0.00-1.00Ind. y Cap.Min. time of connection & disconnection .................................. 50 mAAccuracy ............................................ 1% +- dígitoRatio of current transformer ............... 5/5...10000/5 AMax. time of connection & disconnection ................................. 10...60 sMin. time of connection & disconnection ................................. 2...10 sValue of IND. P.F. adjustment ............ 10%...50%Value of CAP. P.F. adjustment ........... 5%...50%Display ............................................... LED of 4 digit
Protection dig. ........................................ IP 20
Protection dig. of contacts ..................... IP 00
Amtient temp. ........................................ -5ºC...+50ºC
Humidity................................................. 15%...95%
Type of installation ................................. Panel mounting
Dimensions ............................................ 144x144x40 mm
Technical Characteristics Mechanical Characteristics
CodeREG06DPR8500000REG12DPR8500000
Tipo PR-8DPR-8D 6 Steps
PR-8D 12 Steps
PR-8
DAutomatic reactive power controllerPR-8D Series
Dimensions
Vietnam Represented Office:Hancess Vietnam - Quanpham Co.,ltd285 Dien Bien Phu, Ward 07 -district 03, Ho Chi Minh City - Vietnamtel +84 39304952 - 39302400fa: +84 39304953email: [email protected]: www.quanpham.vn
Vietnam Represented Office:RTR Vietnam - Quanpham Co.,ltd285 Dien Bien Phu,Ward 07-district 03, Ho Chi Minh City.VietnamTel +84 39304952 - 39302400Fax: +84 39304953E-mail: [email protected]
Spain:Headquarter & Manufacturing CentreRTR Energia, S.L.C/ Gavilanes, 11 BisPol.lnd. Pinto – Estacion28320 Pinto (Madrid) . SPAINTel.:(+34) 916 916 612Fax : (+34) 916 912 257E-mail:[email protected]
Chile:Manufacturing Centre RTR Energia Chile, S.A.La Estera n 668 Panamericana Norte, Km 17Loteo Valle Grande – Lampa . CHILETel.:(+56) 2 2328 44 00 Fax : (+56) 2 2738 69 11E-mail:[email protected]