5
SYS 201 rt 2u GROUP Mission Critical Applications INFINITE POWER UPS UNINTERRUPTIBLE POWER SUPPLY Double Conversion On-Line Technology Rack Tower Convertible Design VFI Voltage and Frequency Independent Wide Input Voltage and Frequency Windows Active Harmonic Current Control Hot Swappable Battery Unity Input Power Factor (PF = 0.99) Battery Extension Modules Active RS232 & USB & Extended Slot Simultaneously SNMP Management Capability - Extend Slot Mission Critical Servers, Telecommunications, Internet Servers, Network Components, Local Area Networks, VOIP, Process & Telecom Equipment. From 1000 VA to 3000 VA

POWER | SENSYS : SYS 201 RT 2U

Embed Size (px)

Citation preview

Page 1: POWER | SENSYS : SYS 201 RT 2U

SYS 201 rt 2u

GROUP

Mission Critical Applications

INFINITE POWER

UPSUNINTERRUPTIBLE POWER SUPPLY

Double Conversion On-Line TechnologyRack Tower Convertible DesignVFI Voltage and Frequency IndependentWide Input Voltage and Frequency Windows

Active Harmonic Current ControlHot Swappable Battery

Unity Input Power Factor (PF=0.99)Battery Extension ModulesActive RS232 & USB & Extended Slot SimultaneouslySNMP Management Capability - Extend Slot

Mission Critical Servers, Telecommunications,Internet Servers, Network Components,

Local Area Networks, VOIP,Process & Telecom Equipment.

From 1000 VA to 3000 VA

Page 2: POWER | SENSYS : SYS 201 RT 2U

02

UNITY INPUT POWER FACTOR

Meet today´s industry standard for energy saving and low reflected harmonic pollution to the utility.

SINGLE CHIP MICROPROCESSOR CONTROL

The SYS 201 RT 2U uses a field proven MPU to substantially reduce the component count. This provides greater reliability, functionality and smaller size than other designs. Using the latest high frequency techniques and quality components reliability is further increased. High system efficiency is achieved in all operating modes saving electricity.

powerfull LCDDisplay

SYSSYS 201 RT 2UFrom 1000 VA to 3000 VA

EASY COMMUNICATION PLUG & PLAY SELF DIAGNOSTICSEXTENDED BACK UP TIME

overview

In today´s world we are heavily reliant on technology and the power that drives it. If you do not have the correct protection you are putting your business at risk of downtime, lost data and evencomponent damage. The SYS 201 RT is a cost effective way of meeting your critical power needs and integrated seamlessly into the modern network environment.

Page 3: POWER | SENSYS : SYS 201 RT 2U

User friendly display

An easy-to-read LED/LCD display provides real time indication of all major system parameters and status such as operation modes AC voltage, frequency, battery voltage, load level, temperature, etc.

SYS 201 RT 2U

The SYS 201 RT 2U is equipped with advanced digital tecnology, ideal for servers networks,storage, telecom and industrial application.

03

• Maximum flexibility- with the reversible screen can be usedin both tower and 19” rack configuration

• Enables integration into a wide variety of environments

• 2U compact design for alll range with built-in battery

• High power density solution

Battery

••

Remote reboot and load shedding reserving

backup power for critical loads.

Programble Receptables

Rack / Tower convertible DEsign

Convertible design

Extended runtime capability

Run like stabilizer

Powerful buit-in charger

Cold start function

Hot Swappable Battery

From 1000 VA to 3000 VA

Costumers Communications Interface

••

Standard- USB Port, RS232 Port, EPO (emergency off)

Intelligent Shutdown and Monitoring Software•• Patented Technology allows RS232, USB and SNMP slot to be activated simultaneously

Smart Slot Optionals - Internal 2nd RS232 Card, 2nd USB Card, Web / SNMP Card and Dry Contact Card

Page 4: POWER | SENSYS : SYS 201 RT 2U

MODEL SYS 201 RT 2U RT 1kVA RT 2kVA RT 3kVA

INPUT

Voltage Window 160 - 280VAC

Frequency 50/60 Hz ± 5%

Phase Single Phase

Power Factor >0.99

OUTPUT

Voltage

Capacity

220 / 230 / 240VAC

2000 VA / 1600 W 3000 VA / 2400 W1000 VA / 800 W

Voltage Regulation ±%1

Frequency 50/60 Hz

Frequency Stability ± 0,1% unless synch to line

Crest Factor 3:1

Overload Capacity

Wave Form

100%-120% for 30 seconds 120%-150% for 10seconds

Sine Wave, ≤3% THD at linear load; ≤5% at Non-linear load

Inverter E�ciency

Transfer Time 0ms

BATTERY

Type Maintenance-free Sealed Lead Acid

Recharge Time 3 hours to 90%

DC Voltage 36V 72V

Internal Battery 3pcs 12V 7Ah 6pcs 12V 7Ah 6pcs 12V 9Ah

Built in max. Charge Current 1.8A 2.1A 2.7A

Back Up Time Full Load

Managment

5 min 4 min

Half Load 12 min

Advanced Battery Discharge Managment (A B D M)

10 min

Cold Start YES

DISPLAYLED Indicators

LCD Display

Audible and Visual

Hold Whole System

Input /Output Voltage and Frequency Values, Load%, Battery Voltage, Internal Temperature

ALARMS Line Failure, Battery Low, Over Load, Failure Events

PROTECTIONS Short circuit, over temperature, overload, high voltage, battery low, EPO

COMMUNICATIONInterface Type

EPO

Standard RS232 and USB

Contact for UPS Shutdown

Slots

Operating Compatible Platforms

Relay Contact Board, SNMP / WEB Card, 2nd RS323 CArd, 2nd USB Card

Windows 95/98/NT/2000/XP/Vista/Novell NetWare, Linux, etc...

ENVIRONMENT

Temparature 0°C - 40°C

Humidity 0% - 90% (without condensation)

Noise Level(1m distance) <50dBA (at 1 meter)

Protection Class IP 20

PHYSICAL

Outlets 6 pcs IEC or 2pcs Schuko 4pcs IEC or 2pcs Schuko

Dimensions (mm) WxDxH

Net Weight

440x405x88

16 28 30

440x650x88 440x650x88

STANDARDS EN 62040-1-1 (safety), EN 62040-2(EMC) CE, UL, CUL,FCC

Utility or Bypass, Battery Low, Battery Abnormal, Overload, Site Wiring Fault, Service Mode, UPS O�, UPS Abnormal

04

Model

SYS 201 RT 2UFrom 1000 VA to 3000 VA

Page 5: POWER | SENSYS : SYS 201 RT 2U

www.sensysgroup.com

GROUP