11
PCI MOD3,6,30 ANALYSIS AND AUTO OPTIMIZATION GEOGRAPHY STATISTICS

Pci mod3,6,30 analysis and auto optimization

Embed Size (px)

Citation preview

Page 1: Pci mod3,6,30 analysis and auto optimization

PCI MOD3,6,30 ANALYSIS AND AUTO

OPTIMIZATIONGEOGRAPHY STATISTICS

Page 2: Pci mod3,6,30 analysis and auto optimization

HOW TO FIND MOD3,6,30 COLLISION The algorithm can find the MOD(3),MOD(6) and MOD(30) collision for each cell which has cross coverage area with another cell, and this algorithm will implement traversing in every single cell one by one for whole network.

Find MOD(3),MOD(6) and MOD(30) collision cells by particulat algorithm based customer confirmed RSRP

1

Output analysis report and optimization solution

2

Generate Optimization Report

3

Page 3: Pci mod3,6,30 analysis and auto optimization

INPUT DATASITE INFO:1. Longitude, Latitude2. Antenna Height3. Antenna Down tilt4. Site Output Power Parameter for Radio Link Loss Formula

1. F: Frequency2. Hb: Antenna Height3. CH: Environment factor

Interference Level

Page 4: Pci mod3,6,30 analysis and auto optimization

OPTIMIZATION PROCEDURESite Info

Logitude, Latitude

Height, Down Tilt

Tx_Power

Parameter for Radio Link Loss

f: Frequency

Hb : Site Height

CH : Environment

Radio Link LossLu=69.55+26.16*log(f)-13.82*log(Hb)-CH+[44.9-6.55*log(Hb)]*log(d)

Input RSRP Level:Such as -85dBm

Output Cell Coverage Radius

Mod(3)Cross Coverage Area

A

B

Page 5: Pci mod3,6,30 analysis and auto optimization

OUTPUT DATA1. Cell MOD(3),MOD(6) and MOD(30) analysis report;2. MOD(3),MOD(6) and MOD(30) thematic map;3. Candidate PCI Value List;4. Optimization Report

The following slides will show you more information regarding these topics.

Page 6: Pci mod3,6,30 analysis and auto optimization

GENERATE PCI ANALYSIS REPORT

CELL NAME PCI MOD(3) MOD(6) MOD(30) Cell Name Cross Coverage Area PCI Distance(M) MOD(3) MOD(6) MOD(30) MOD(3) MOD(6) MOD(30)City_Center_1 122 2 2 2 ShopingMall_1 50 3 520 0 3 3 N N NCity_Center_1 122 2 2 2 Pharmacy_2 33 78 480 0 0 18 N N NCity_Center_1 122 2 2 2 School_2 35 89 610 2 5 29 Y N NCity_Center_2 123 0 3 3 Hotel_3 76 264 480 0 0 24 Y N NCity_Center_2 123 0 3 3 Kindergarten_

2 34 67 560 1 1 7 N N NCity_Center_2 123 0 3 3 Hospital_2 23 100 550 1 4 10 N N NCity_Center_2 123 0 3 3 Park_1 44 111 780 0 3 21 Y Y NCity_Center_3 124 1 4 4 Police_2 53 222 660 0 0 12 N N NCity_Center_3 124 1 4 4 Caffee_1 21 333 770 0 3 3 N N NCity_Center_3 124 1 4 4 Palace_3 18 454 670 1 4 4 Y Y Y

This report will show you a clear picture regarding the MOD(3), MOD(6) and MOD(30) collision base on the RSRP which user definition.

Page 7: Pci mod3,6,30 analysis and auto optimization

GENERATE PCI MOD THEMATIC MAP

Page 8: Pci mod3,6,30 analysis and auto optimization

DELIVERY OPT REPORTNumber of Collision cells

Before optimization

After optimization

MOD(3) 100 0MOD(6) 80 10MID(30) 60 5

Sum Collision Area

Before Optimization

After Optimization

MOD(3) 16789 560

MOD(6) 80 10

MID(30) 60 5

Netwrork 优化前 优化后 提高Access Success Rate 98% 99% 1.02%Downlink Throughput(kbps) 1432 1456 1.68%

MOD-0 MOD-1 MOD-20

50

100

150

200

250

0.00%5.00%10.00%15.00%20.00%25.00%30.00%35.00%40.00%45.00%50.00%

FREQUENCY 38400 PCI MOD(3)

Num_Cell Percent

MOD-0 MOD-1 MOD-2 MOD-3 MOD-4 MOD-50

20

40

60

80

100

120

0.00%

5.00%

10.00%

15.00%

20.00%

25.00%

FREQUENCY 38400 PCI MOD(6)

Num_Cell Percent

MOD-0

MOD-2

MOD-4

MOD-6

MOD-8

MOD-10

MOD-12

MOD-14

MOD-16

MOD-18

MOD-20

MOD-22

MOD-24

MOD-26

MOD-28

0

5

10

15

20

25

0.00%0.50%1.00%1.50%2.00%2.50%3.00%3.50%4.00%4.50%5.00%

FREQUENCY 38400 PCI MOD(30)

Num_Cell Percent

Page 9: Pci mod3,6,30 analysis and auto optimization

ADVANCED FEATURE (1) 1. Single Cell PCI Tuning Base on the output report, you will get the mod(3),mod(6) and mod(30) collision cells list, and then system will provide you a candidate value list support you to find the prober PCI.

The following table is an example which system will show you after big data analysis.PCI MOD(3) MOD(6) MOD(30) Cross Area Cell Distance

128 2 2 8 0 Without Collision Cell

179 2 5 29 8 1.3KM234 0 0 24 12 0.9KM156 0 0 6 14 0.8KM

Page 10: Pci mod3,6,30 analysis and auto optimization

ADVANCED FEATURE (2) . Whole network PCI smart distribution Once the RSRP confirmed, the system can fill the following table, and then implement the algorithm to distribute PCI with different mod(3),mod(6) and mod(30) values for the cells which get cross area from maximum to minimum.

Finally, we will make the network with minimum cross coverage area with mod(3),mod(6) and mod(30) collision. And also base on the big data analysis, we will put solution as well, to adjust some particular cell’s antenna down tilt to make the mod collision as small as possible.

CELL NAME PCI MOD(3) MOD(6) MOD(30) Cell Name Cross Coverage Area PCI Distance(M) MOD(3) MOD(6) MOD(30) MOD(3) MOD(6) MOD(30)City_Center_1 122 2 2 2 ShopingMall_1 50 3 520 0 3 3 N N NCity_Center_1 122 2 2 2 Pharmacy_2 33 78 480 0 0 18 N N NCity_Center_1 122 2 2 2 School_2 35 89 610 2 5 29 Y N NCity_Center_2 123 0 3 3 Hotel_3 76 264 480 0 0 24 Y N NCity_Center_2 123 0 3 3 Kindergarten_

2 34 67 560 1 1 7 N N NCity_Center_2 123 0 3 3 Hospital_2 23 100 550 1 4 10 N N NCity_Center_2 123 0 3 3 Park_1 44 111 780 0 3 21 Y Y NCity_Center_3 124 1 4 4 Police_2 53 222 660 0 0 12 N N NCity_Center_3 124 1 4 4 Caffee_1 21 333 770 0 3 3 N N NCity_Center_3 124 1 4 4 Palace_3 18 454 670 1 4 4 Y Y Y

Page 11: Pci mod3,6,30 analysis and auto optimization

end