6
Crown Corrosion PREPARED BY MR.MAYANK OZA

Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

Embed Size (px)

Citation preview

Page 1: Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

Crown Corrosion

PREPARED BY MR.MAYANK OZA

Page 2: Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

What is Crown Corrosion?

Bacteria in the slime under flowing sewage convert sulphates in the sewage into sulphides.

Sulphides in the liquid make their way to the surface of the sewage and released into the sewer atmosphere as hydrogen sulphide (H2S) gas.

Prepared by mr.mayank oza

Page 3: Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

Causes for Crown Corrosion

Prepared by mr.mayank oza

Page 4: Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

Corrosion Control MeasuresThe following measures should be considered during design for corrosion control in SewersDesign shall provide for self-cleansing velocity, good ventilation, low turbulence, flushing facilities, minimal periods of flow and minimum stagnation.Pipes made of inert materials are preferable.In case of large diameter pipes, RCC with sacrificial lining of 25 to 50mm thick is the suitable pipe material.Lining the inside of the RCC pipe with sulphate resistant or high alumina cement as sacrificial.layer may increase the life expectancy of the pipe by 3 to 5 times.RCC pipes are manufactured with sulphate resistant cement when the soil contains sulphur and other corrosive substances.

Prepared by mr.mayank oza

Page 5: Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

Corrosion Control MeasuresFor metallic pipes (DI or MS) the acceptable linings are cement mortar lining either with sulphate resistant or high alumina cement.

The design of sewer section with a depth of flow of about 0.8D will minimize the chance of corrosion.

Good ventilation usually removes condensation in the immediate vicinity of the air inlet.

Periodic flushing of sewers is necessary to•remove solids accumulation and control their subsequent anaerobic decomposition and H2S formation

Prepared by mr.mayank oza

Page 6: Crown corrosion - wwwe - By Mr. Mayank Oza - water and waste water engineering

Thank You!

Prepared by mr.mayank oza