A case study on total Energy Conservation opportunities in a Solar power assisted building
Project Batch No. 15Abhilash Mohanty (11EE016)Deepayan Panigrahi (11EE017)Ambika Prasanna Dhal (11EE018)
Under the esteemed guidance of G.R.K.D. Satya PrasadAssociate ProfessorDepartment of Electrical Engineering, GIET, Gunupur-765
022
Department of Electrical Engineering, GIET, Gunupur-765 022
Contents Objective Importance of Energy Conservation Latest technologies in Energy conservation Need for Energy Audit Types of Energy Audit Conservation Opportunities in terms of Electrical
loads Result Analysis & Report Energy Consumption in GIET Total Savings Conclusion
3
Department of Electrical Engineering, GIET, Gunupur-765 022
Objective
The main objective of this project is to carry out an analysis on GIET campus in terms of optimising total load, by different conservation approaches.
The best possible combination of load and energy efficient methods to be used so as to reduce energy use.
4
Department of Electrical Engineering, GIET, Gunupur-765 022
Importance of Energy Conservation
Energy conservation refers to the concept of reducing energy consumption through using less of an energy service.
Most of the energy we use cannot be reused and renewed.
Energy conservation is important when it comes to climate change.
Energy conservation is needed to reduce the adverse effect of pollution due to excessive use of fossil fuels.
Increasing energy demand is a drain to national economy.
5
Department of Electrical Engineering, GIET, Gunupur-765 022
Energy efficient building Waterproofing Advance metering (Totally integrated energy monitoring
system) SCADA (Real time information for power monitoring ) Energy Efficient motors and Variable frequency drives, etc.
Latest technologies in Energy conservation
6
Department of Electrical Engineering, GIET, Gunupur-765 022
Energy audits that save energy.
Education on how to save energy.
Incentives for purchasing new homes built to ENERGY
STAR guidelines.
Rebates on purchases of energy-efficient products,
including appliances, lighting, and HVAC
equipment.
Role of Energy conservation in reducing the electricity bills
7
Department of Electrical Engineering, GIET, Gunupur-765 022
Energy Audit is the key to a systematic approach for
decision-making in the area of energy conservation
management.
It attempts to balance the total energy inputs with its
use, and serves to identify all the energy streams in a
facility and quantifies energy usages.
Assessing the Energy conservation procedure
8
Department of Electrical Engineering, GIET, Gunupur-765 022
The primary objective of Energy Audit is to determine
ways to reduce energy consumption.
Energy Audit will help to understand more about the
ways energy and fuel are used in any industry, and help
in identifying where scope for improvement exists.
The Energy Audit would give a positive orientation to
the energy cost reduction, preventive maintenance and
quality control programs.
Need for Energy Audit
9
Department of Electrical Engineering, GIET, Gunupur-765 022
Electrical energy is measured in kilowatt-hours (KWH). Energy and demand are the two items that usually determine the electric bill. It is important to understand how the electric bill is determined. This alone can often save money, if not energy. So lighting and motors and some miscellaneous items can be changed to improve electrical efficiency.
Conservation Opportunities in terms of
Electrical loads
10
Department of Electrical Engineering, GIET, Gunupur-765 022
Energy Audit was conducted in the entire college campus. Lighting load, HVAC load, motors load, total load calculation etc., gathered the information in all levels to finalize the total energy audit.
Result Analysis
11
Department of Electrical Engineering, GIET, Gunupur-765 022
The whole campus energy audit provided: A baseline from which improvement can be measured. A plan of action which will allow the organization to
improve their energy performance, reduce electricity bills and better environment practice.
Share the positive results. Implement new plan. Evaluate and assess the success of the audit. Identify problem areas and devise plans to tackle
problems.
Result Analysis
12
Department of Electrical Engineering, GIET, Gunupur-765 022
Energy Consumption in GIET
Total lighting load
790 2478 664 17 1046
TL20
TL40
TL( D)40
IL100
CFL23
Types of load Total Consumption
60W Fans load: 209142 KWH
Power consumption of CRT monitors:
15000 units
Pumps 61,125 watts
Air conditioner loads 203526 units
Lighting load
13Energy Conservation procedure
Optimized use of light, like use of T5 tube lights, sensors in libraries, LED lighting, running a separate line for lighting load and voltage reduction for lighting load
Use of electronic Fan regulator Use Electronic ballasts, The conventional choke
consumes 50 watts of electrical energy (for 40W tube) while electronic ballast consumes only 30W thereby saving 20W per tube
Department of Electrical Engineering, GIET, Gunupur-765 022
14
Department of Electrical Engineering, GIET, Gunupur-765 022
Factors of
comparison
Ordinary Bulb
(100W)
CFL range
(1w)
Lamp Life 1000 yrs. 8000 yrs.
Required No. Of
lamps
Eight One
Cost of
lamps/lamp
8xRs.10 1 x Rs.235
Cost of Elec.
Rs.3.50
Per KWh + cost
of lamp
Rs.1760 RS: 599
Type of Fans Conventional
Regulator
Electronic
Regulator
Cheap quality
fans
75W 70W
ISI Standard
fans
65W 60W
Item Description Conventional
Choke
(duplicate)
Conventional
Choke
(ISI marked)
Electronic
Choke
Power 58W 45W 25w
Energy
Consumption
KWh=3.90/-
741+80=821/- 575+200=775/- 320+225=545/-
Use of CFL Lights Use of Electronic Choke
Use of Electronic regulator
15Electricity Bill
Department of Electrical Engineering, GIET, Gunupur-765 022
16
Department of Electrical Engineering, GIET, Gunupur-765 022
17
Department of Electrical Engineering, GIET, Gunupur-765 022
18Comparison of expenses in
electricity bills for the years 2012, 2013 and 2014
YEARUNITS
CONSUMPTIONTOTAL BILL IN ₹ (INR)
EXCESS/ DECREASE IN ₹
(INR)2012 12,62,595 74,64,873 ________
2013 14,01,792 86,47,701 + 11,82,828
2014 12,67,844 81,62,271 - 4,85,430
Department of Electrical Engineering, GIET, Gunupur-765 022
19Result
According to the analysis in 2012 the units consumption was 12, 62, 595 which had cost around 74, 64, 873Rs/- , then with increase in load in 2013 the unit consumption raised to 14, 01, 792 which nearly had cost around 86, 47, 701Rs/-. Taking the expenses of these years there is an increase of 15.84% from 2012 to 2013.
From 2014 onwards we started following energy conservation procedures, due to which though the load increased by 10% as we came up with a new R&D building but the expenses on electricity bill decreased by 5.61%.
Department of Electrical Engineering, GIET, Gunupur-765 022
20
Department of Electrical Engineering, GIET, Gunupur-765 022
Energy plays a key role in achieving the desired economic growth and energy conservation promises to fill the gap between supply and demand.
Energy conservation accelerates supply side capacity, operational efficiency improvements of power generating stations, reduction of losses in transmission and distribution, end-use efficiency and renewable technologies thereby mitigating environmental pollution.
Conclusion
21Future Scope
Energy conservation procedures can be followed to
construct Smart building. Smart building deliver useful
building services that make occupants productive (e.g.
illumination, thermal comfort, air quality, physical
security, sanitation and many more) at the lowest cost
and environmental impact over the building lifecycle.
22