Zip Heaters (Aust) Pty Ltd 67-77 Allingham St, Condell Park NSW 2200 Australia1800 42 43 44 | zipwater.com
ZIP HYDROTAP G4
THE ENVIRONMENTALLY RESPONSIBLE CHOICEWorld class air cooled technologyThe following document provides information on the various options for the provision of adequate air circulation within the cupboard space
Providing correct air flow results in the following:• Optimal performance• Up to 53% reduction in energy consumption* • Reduced wear and tear on components• Reduced maintenance• Extended product life• Reduced running costs*energy reduction compared with previous generation of products, refer to Sustainability Brochure for further details.
AIR
COOLE D
WATER
COOLE D
AIR
COOLE D
WATER
COOLE D
AIR
COOLE D
WATER
COOLE D
AIR
COOLE D
WATER
COOLE D
Cool Air IN via cabinet floor, front vent grille
Warm Air OUT via kickboard louvre
MIN.50mmAir Gap
**MIN.100mm
Min 450mm
=
=
max
43
314.00
12.00
12.00
285.00
12.
00
5
326.00
CUT OUT DETAILS
A
A - KICKBOARD CUT-OUT
1.Drill 4 pilot holes Ø12 in corners2.Finish cut-out using Jigsaw and Keyhole or Wall Board saw
B - CABINET FLOOR CUT-OUT
1.Drill two pilot holes Ø122.Finish cut-out using Jigsaw
C - CABINET FLOOR CUT-OUT
1.Drill 4 pilot holes Ø12 in corners 2.Finish cut-out using Jigsawand Keyhole or Wall Board saw
ATTENTION:Insure that: Cut outs 'A' and 'B' are on opposite side of cabinet. Cut out 'C' is straight behind'A'
60.00
BC
12.00
45.00
284
For positioning of cutout C use the template marked on the cardboard carton
RECOMMENDED INSTALLATION Proper air circulation must be provided for commercial HydroTap models that have chilled or chilled sparkling functionality. The HydroTaps unique Cross-Flow kit is supplied with the product and is designed to ensure optimum efficiency using forced air flow. If this kit cannot be fitted one of the other available options will need to be installed.
HYDROTAP G4 CROSS-FLOW
Typical Cut out arrangement for Chilled Sparkling models with kickboard venting via a left hand appliance duct
Typical Cut out arrangement for Boiling Chilled Sparkling models with kickboard venting via a right hand appliance duct
A
A
B
C
B
C
CHILLED SPARKLING
BOILING CHILLED SPARKLING
HYDROTAP G4 CROSS-FLOW
HYDROTAP G4 VENT TRAY KIT
The Vent Tray Kit should be used to provide proper air circulation when the Cross-Flow kit which is supplied with commercial HydroTap models that have chilled or chilled sparkling functionality cannot be fitted. The HydroTap will only operate at its optimum efficiency if the recommended air flow is achieved.
Installation showing the correct Air Flow using the vent tray.
INSTALLATION OPTION 1
93540 assembled vent tray kit
50mm adjustment
Alignment marks
Outlet Duct
50mm
450mm cut out
1
2
Air Inlet option
Air Inlet option
Warm air Outlet vent
adjustable to suit the depthof the Base unit.
430
404.9
30 36
30
465
496
46
284
56.9
440.5
TOP VIEW(FRONT COVER REMOVED FOR CLARITY)
10
484 494.5
400
FRONT VIEW 40
10
88
16.2
43.6
RHS VIEW
adjustable to suit the depthof the Base unit.
430
404.9
30 36
30
284
80.7
113 46
465
496
TOP VIEW(FRONT COVER REMOVED FOR CLARITY)
10
484 494.5
400
FRONT VIEW
40
10
88
16.2
43.6
RHS VIEW
Vent Tray Kit for BC and BCS Commercial Models, part #93540
Vent Tray Kit for C and CS Commercial Models, Part #93541
HYDROTAP G4 VENT TRAY KIT
Installation showing the correct Air Flow using the Dual exhaust Fan kit.
The Dual Exhaust Fan Kit should be used to provide proper air circulation when the Cross-Flow kit which is supplied with commercial HydroTap models that have chilled or chilled sparkling functionality cannot be fitted. The HydroTap will only operate at its optimum efficiency if the recommended air flow is achieved.
Zip Accessories Dual exhaust Fan kit, part #93156 Dual exhaust fan kit with digital cupboard temperature controller, part 93159* *some HydroTap models do not have the 2 pin DIN plug required to run the dual exhaust fan, in these instances you will require the digital tem-perature controller to operate the fan kit.
HYDROTAP G4 DUAL EXHAUST FAN KIT
Digital controller
230V AC to 12V DC Power supply
Fan plug
Air Inlet grill
Inlet grill cut out
Exhaust fan
228
98
Exhaust fan cut out
Typical installation for BC and BCS models
INSTALLATION OPTION 2
Warm air outlet
option 2
Warm air outlet option 1