1/17/2017
RELIABILITY MONITOR REPORT
FOR
WLP Package
MAXIM INTEGRATED
160 RIO ROBLES
SAN JOSE, CA 95134
This Report was prepared by
MAXIM INTEGRATED Reliability Engineering
Summary:
The data in the tables that follow was generated as the result of an on-going Package Reliability Monitor. The specifc assemblies included in this package monitor are:
The calculated failure rate for this assembly is:
The parameters used to calculate this failure rate are as follows:
Cf: 60% Ea: 0.7 Tu: 25 °C
The reliability data follows. A the start of this data is a description of the assembly vehicle used to generate this reliability data. The next section is the detailed reliability data for each stress. The reliability data section includes the latest data available. This report covers data between and .
10/1/2016 12/31/2016
ASSY SITE PACKAGEPINS
ASE Chung-Li TWLP (Pb-Free)36 ASE Kaoshiung TWLP (Pb-Free)4
ASE Kaoshiung TWLP (Pb-Free)8 ASE Kaoshiung TWLP (Pb-Free)12
ASE Kaoshiung TWLP (Pb-Free)36 ASE Kaoshiung UTWLP (Pb-Free)9
ASE Kaoshiung WLP30 ASE Kaoshiung WLP (Pb-Free)6
ASE Kaoshiung WLP (Pb-Free)8 ASE Kaoshiung WLP (Pb-Free)9
ASE Kaoshiung WLP (Pb-Free)12 ASE Kaoshiung WLP (Pb-Free)25
ASE Kaoshiung WLP (Pb-Free)30 ASE Kaoshiung WLP (Pb-Free)32
ASE Kaoshiung WLP (Pb-Free)36 ASE Kaoshiung WLP (Pb-Free)40
ASE Kaoshiung WLP (Pb-Free)42 ASE Kaoshiung WLP (Pb-Free)49
ASE Kaoshiung WLP (Pb-Free)54 ASE Kaoshiung WLP (Pb-Free)56
ASE Kaoshiung WLP (Pb-Free)81 ASE Kaoshiung WLP (Pb-Free)99
ASE Kaoshiung WLP (Pb-Free)110 ASE Kaoshiung WLP (Pb-Free)121
ASE Kaoshiung WLP-HC (Pb-Free)9 ASE Penang TWLP (Pb-Free)6
ASE Penang TWLP (Pb-Free)36 ASE Penang WLP (Pb-Free)49
ASE Penang WLP (Pb-Free)99 Dallas TWLP (Pb-Free)36
Dallas UTWLP (Pb-Free)49 Dallas WLP (Pb-Free)6
Dallas WLP (Pb-Free)49 Dallas-Maxfilm UTWLP (Pb-Free)6
Dallas-Maxfilm UTWLP (Pb-Free)9 Dallas-Maxfilm UTWLP (Pb-Free)49
Dallas-Maxfilm WLP (Pb-Free)6 Dallas-Maxfilm WLP (Pb-Free)9
Dallas-Maxfilm WLP (Pb-Free)30 Dallas-Maxfilm WLP (Pb-Free)49
Dallas-Maxfilm WLP-HC (Pb-Free)9 FLIPCHIP TECH WLP (Pb-Free)9
JCAP WLP (Pb-Free)81 JCAP WLP (Pb-Free)144
UTL (NSEB) UTAC TWLP (Pb-Free)6
Package Type: TWLP (Pb-Free)
Assembly Information:
N/A1606 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000135°C 80 0HIGH TEMP OP LIFE HRS1620 VT1677SBFQ
1000135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX11291ENX+TCL6
1000135°C 80 0HIGH TEMP OP LIFE HRS1622 MAX11291ENX+TCL6
1000135°C 80 0HIGH TEMP OP LIFE HRS1623 VT1677SB
FAILURE RATE: MTTF (YRS): 1141552 FITS: 0.1
1000135°C 80 0HIGH TEMP OP LIFE HRS1624 VT1677SB
1000135°C 80 0HIGH TEMP OP LIFE HRS1624 VT1677SB
1000135°C 80 0HIGH TEMP OP LIFE HRS1627 MAX11291ENX+TCL6
192135°C 80 0HIGH TEMP OP LIFE HRS1643 MAX14708ENA+TG7
192135°C 80 0HIGH TEMP OP LIFE HRS1645 MAX14708ENA+TG7
1000135°C 80 0HIGH TEMP OP LIFE HRSN/A VT1677/ VSC1363
0Total:
STORAGE LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000150°C 80 0STORAGE LIFE HRS1608 MAX11291ENX+TCL6
1000150°C 80 0STORAGE LIFE HRS1620 VT1677SBFQ
1000150°C 79 0STORAGE LIFE HRS1621 MAX11291ENX+TCL6
1000150°C 80 0STORAGE LIFE HRS1622 MAX11291ENX+TCL6
1000150°C 80 0STORAGE LIFE HRS1623 VT1677SB
1000150°C 80 0STORAGE LIFE HRS1624 VT1677SB
1000150°C 80 0STORAGE LIFE HRS1624 VT1677SB
600150°C 50 0STORAGE LIFE HRS1643 MAX14708ENA+TG7
0Total:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1606 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1606 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX11291ENX+TCL6
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX11291ENX+TCL6
1000-65C TO +150C (Condition C) 80 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1623 VT1677SB
1000-65C TO +150C (Condition C) 80 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1624 VT1677SB
1000-65C TO +150C (Condition C) 80 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1624 VT1677SB
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX11291ENX+TCL6
1000-65C TO +150C (Condition C) 79 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1627 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX11291ENX+TCL6
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX14710ENC+
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1631 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1635 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1635 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1635 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX20312ENS+TG7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX20312ENS+TG7
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX11291ENX+TCL6
850-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX11291ENX+TCL6
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX11291ENX+TCL6
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX11291ENX+TCL6
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX11291ENX+TCL6
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1638 MAX20312ENS+TG7
0Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 VT1677SBFQ
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 VT1677SBFQ
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX11291ENX+TCL6
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1623 VT1677SB
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1625 MAX11291ENX+TCL6
96130C, 85% R.H. 77 0BIASED MOISTURE HRS1628 MAX14710ENC+
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1628 MAX14710ENC+
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1628 MAX14710ENC+
96130C, 85% R.H. 77 0BIASED MOISTURE HRS1628 MAX14710ENC+
96130C, 85% R.H. 77 0BIASED MOISTURE HRS1628 MAX14710ENC+
96130C, 85% R.H. 77 0BIASED MOISTURE HRS1628 MAX14710ENC+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1637 MAX11291ENX+TCL6
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1637 MAX11291ENX+TCL6
0Total:
UNBIASED MOISTURE RESISTANCE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX11291ENX+TCL6
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX11291ENX+TCL6
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX11291ENX+TCL6
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX11291ENX+TCL6
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX11291ENX+TCL6
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1622 MAX11291ENX+TCL6
125085 C/85% R.H. 80 0MOISTURE SOAK HRS1622 MAX11291ENX+TCL6
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1624 VT1677SB
125085 C/85% R.H. 80 0MOISTURE SOAK HRS1625 MAX11291ENX+TCL6
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX11291ENX+TCL6
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1631 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1635 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1635 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1635 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1635 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1637 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1637 MAX20312ENS+TG7
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1638 MAX20312ENS+TG7
0Total:
Package Type: UTWLP (Pb-Free)
Assembly Information:
16391511 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
192135°C 80 0HIGH TEMP OP LIFE HRS1511 MAX77231EZL+T
192135°C 80 0HIGH TEMP OP LIFE HRS1535 MAX44290ANT+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1538 MAX20301ENL+CM9
500135°C 80 0HIGH TEMP OP LIFE HRS1540 MAX20301ENL+CM9
1000135°C 80 0HIGH TEMP OP LIFE HRS1540 MAX20301ENL+CM9
1000135°C 80 0HIGH TEMP OP LIFE HRS1545 MAX20301ENL+CM9
500135°C 80 0HIGH TEMP OP LIFE HRS1545 MAX20301ENL+CM9
1000135°C 80 0HIGH TEMP OP LIFE HRS1545 MAX98726AENJ+TCLL
1000135°C 80 0HIGH TEMP OP LIFE HRS1545 MAX98726AENJ+TCLL
1000135°C 80 0HIGH TEMP OP LIFE HRS1546 MAX20301ENL+CM9
1000135°C 80 0HIGH TEMP OP LIFE HRS1548 MAX98726AENJ+TCLL
192135°C 80 0HIGH TEMP OP LIFE HRS1549 MAX20300ENL+CM0
1000135°C 80 0HIGH TEMP OP LIFE HRS1549 MAX20300ENL+CM0
0Total:
STORAGE LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000150°C 50 0STORAGE LIFE HRS1538 MAX20301ENL+CM9
1000150°C 50 0STORAGE LIFE HRS1540 MAX20301ENL+CM9
1000150°C 50 0STORAGE LIFE HRS1545 MAX20301ENL+CM9
500150°C 50 0STORAGE LIFE HRS1545 MAX20301ENL+CM9
1000150°C 80 0STORAGE LIFE HRS1545 MAX98726AENJ+TCLL
1000150°C 80 0STORAGE LIFE HRS1545 MAX98726AENJ+TCLL
1000150°C 80 0STORAGE LIFE HRS1548 MAX98726AENJ+TCLL
1000150°C 50 0STORAGE LIFE HRS1549 MAX20300ENL+CM0
1000150°C 80 0STORAGE LIFE HRS1620 MAX14709ENL+TCL7
0Total:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1538 MAX20301ENL+CM9
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1538 MAX20301ENL+CM9
250-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1540 MAX20300ENL+TCM0
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1540 MAX20300ENL+TCMO
200-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1540 MAX20300ENL+TCM0
700-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1540 MAX20300ENL+TCM0
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1541 MAX98726AENJ+TCLL
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1541 MAX98726AENJ+TCLL
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX20301ENL+TCM9
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX20301ENL+TCM9
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98726AENJ+TCLL
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98726AENJ+TCLL
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX98726AENJ+TCLL
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX98726AENJ+TCLL
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX20300ENL+TCM0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX20300ENL+TCM0
700-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX20300ENL+TCM0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX20300ENL+TCM0
700-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1549 MAX20300ENL+TCM0
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1550 MAX98726AENJ+TCLL
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1551 MAX20300ENL+TCM0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1603 MAX98726BENJ+CNF
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1605 MAX20301ENL+CM9
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1605 MAX20301ENL+CM9
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1611 MAX20300ENL+TCM0
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1620 MAX14709ENL+TCL7
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1624 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 72 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98726BENJ+CNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1629 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX98726BENJ+TCNF
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1632 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1635 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1635 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1638 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1638 MAX20300ENL+TCM0
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1639 MAX20300ENL+TCM0
0Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1538 MAX20301ENL+CM9
264130C, 85% R.H. 78 0BIASED MOISTURE HRS1540 MAX20300ENL+TCM0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1545 MAX20301ENL+TCM9
264130C, 85% R.H. 79 0BIASED MOISTURE HRS1545 MAX98726AENJ+TCLL
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1545 MAX98726AENJ+TCLL
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1549 MAX20300ENL+TCM0
100085 C/85% R.H. 77 0BIASED MOISTURE HRS1549 MAX20300ENL+TCM0
30085 C/85% R.H. 80 0BIASED MOISTURE HRS1549 MAX20300ENL+TCM0
90085 C/85% R.H. 77 0BIASED MOISTURE HRS1549 MAX20300ENL+TCM0
40085 C/85% R.H. 80 0BIASED MOISTURE HRS1549 MAX20300ENL+TCM0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1550 MAX98726AENJ+TCLL
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1603 MAX98726BENJ+CNF
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1620 MAX14709ENL+TCL7
0Total:
UNBIASED MOISTURE RESISTANCE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1538 MAX20301ENL+CM9
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1540 MAX20300ENL+TCM0
100085 C/85% R.H. 79 0MOISTURE SOAK HRS1540 MAX20300ENL+TCM0
40085 C/85% R.H. 80 0MOISTURE SOAK HRS1540 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1545 MAX20301ENL+TCM9
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1545 MAX98726AENJ+TCLL
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1545 MAX98726AENJ+TCLL
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1549 MAX20300ENL+TCM0
100085 C/85% R.H. 80 0MOISTURE SOAK HRS1549 MAX20300ENL+TCM0
20085 C/85% R.H. 80 0MOISTURE SOAK HRS1549 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1550 MAX98726AENJ+TCLL
100085 C/85% R.H. 73 0MOISTURE SOAK HRS1551 MAX20300ENL+TCM0
60085 C/85% R.H. 80 0MOISTURE SOAK HRS1551 MAX20200ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1551 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1603 MAX98726BENJ+CNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1605 MAX20301ENL+CM9
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1611 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1623 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1624 MAX98726BENJ+TCNF
96130C, 85% R.H. 71 0MOISTURE SOAK HRS1626 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98726BENJ+CNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1629 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX98726BENJ+TCNF
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1632 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1634 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1635 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1635 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1638 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1638 MAX20300ENL+TCM0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1639 MAX20300ENL+TCM0
0Total:
Package Type: WLP
Assembly Information:
16111611 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
192135°C 48 0HIGH TEMP OP LIFE HRS1611 MAX20306EWV+
0Total:
Package Type: WLP (Pb-Free)
Assembly Information:
16461316 toDate Code Range:
OPERATING LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
192135°C 80 0HIGH TEMP OP LIFE HRS1316 MAX77833EWM+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1509 MAX98721BEWV+TF80
192135°C 80 0HIGH TEMP OP LIFE HRS1515 MAX14738EWT+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1533 MAX98706EWW+CLE
500135°C 80 0HIGH TEMP OP LIFE HRS1539 MAX98706AEWV+TCLE
192135°C 48 0HIGH TEMP OP LIFE HRS1540 MAX77854EWZ+T
500135°C 80 0HIGH TEMP OP LIFE HRS1542 MAX98706AEWV+TCLE
500135°C 80 0HIGH TEMP OP LIFE HRS1545 MAX98706AEWV+TCLE
1000135°C 77 0HIGH TEMP OP LIFE HRS1545 MAX98304DEWL+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1545 MAX98304DEWL+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1545 MAX98304DEWL+T
192135°C 80 0HIGH TEMP OP LIFE HRS1548 MAX14746BEWA+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1613 MAX98304DEWL+T
1000135°C 76 0HIGH TEMP OP LIFE HRS1613 MAX98304DEWL+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1613 MAX77843EWV+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1613 MAX77843EWV+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1613 MAX8986EWG+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1613 MAX8986EWG+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1613 MAX8986EWG+T
192135°C 48 0HIGH TEMP OP LIFE HRS1614 MAX98507BEWX+T
1000135°C 77 0HIGH TEMP OP LIFE HRS1614 MAX98304DEWL+T
500135°C 77 0HIGH TEMP OP LIFE HRS1614 MAX5394LANA+TCGS
500135°C 77 0HIGH TEMP OP LIFE HRS1614 MAX5394LANA+TCGS
500135°C 80 0HIGH TEMP OP LIFE HRS1616 MAX98706AEWV+TCLE
1000135°C 80 0HIGH TEMP OP LIFE HRS1619 MAX98721DEWV+TFA0
500135°C 80 0HIGH TEMP OP LIFE HRS1619 MAX98721DEWV+TFA0
500135°C 80 0HIGH TEMP OP LIFE HRS1619 MAX98721DEWV+TFA0
1000135°C 80 0HIGH TEMP OP LIFE HRS1619 MAX98721DEWV+TFA0
1000135°C 77 0HIGH TEMP OP LIFE HRS1619 MAX98721DEWV+TFA0
500135°C 77 0HIGH TEMP OP LIFE HRS1620 MAX77686EWE+
1000135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX77843EWV+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX77843EWV+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX77843EWV+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX77843EWV+T
1000135°C 79 0HIGH TEMP OP LIFE HRS1621 MAX77843EWV+T
1000135°C 79 0HIGH TEMP OP LIFE HRS1621 MAX77843EWV+T
500135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX98730EWJ+TCGT
1000135°C 80 0HIGH TEMP OP LIFE HRS1621 MAX98730EWJ+TCGT
500135°C 77 0HIGH TEMP OP LIFE HRS1621 MAX77686EWE+
500135°C 77 0HIGH TEMP OP LIFE HRS1621 MAX77686EWE+
192135°C 48 0HIGH TEMP OP LIFE HRS1622 MAX32620B
1000135°C 80 0HIGH TEMP OP LIFE HRS1622 MAX98730EWJ+TCGT
500135°C 80 0HIGH TEMP OP LIFE HRS1623 MAX16124WTEQ00+G7
125135°C 77 0HIGH TEMP OP LIFE HRS1623 MAX8986EWG+
125135°C 77 0HIGH TEMP OP LIFE HRS1623 MAX8986EWG+
1000135°C 77 0HIGH TEMP OP LIFE HRS1623 MAX8986EWG+
126135°C 77 0HIGH TEMP OP LIFE HRS1623 MAX8986EWG+
192135°C 79 0HIGH TEMP OP LIFE HRS1626 MAX14745AEWX+T
1000135°C 80 0HIGH TEMP OP LIFE HRS1626 MAX98706AEWV+TCLE
500135°C 80 0HIGH TEMP OP LIFE HRS1628 MAX16124WTEQ00+G7
192135°C 48 0HIGH TEMP OP LIFE HRS1629 MAX77910EWW+T
192135°C 80 0HIGH TEMP OP LIFE HRS1632 MAX14743EWC+
192135°C 80 0HIGH TEMP OP LIFE HRS1633 MAX98925EWV+T
500135°C 80 0HIGH TEMP OP LIFE HRS1636 MAX9027EWT+
192135°C 48 0HIGH TEMP OP LIFE HRS1640 MAX77865FSEWZ+T
192135°C 48 0HIGH TEMP OP LIFE HRS1642 MAX77854EWZ+T
1000135°C 46 0HIGH TEMP OP LIFE HRS1646 MAX98706AEWV+TCLE
0Total:
STORAGE LIFE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
1000150°C 80 0STORAGE LIFE HRS1533 MAX98706EWW+CLE
500150°C 80 0STORAGE LIFE HRS1539 MAX98706AEWV+TCLE
500150°C 79 0STORAGE LIFE HRS1542 MAX98706AEWV+TCLE
1000150°C 77 0STORAGE LIFE HRS1544 MAX8986EWG+T
1000150°C 77 0STORAGE LIFE HRS1544 MAX8986EWG+T
1000150°C 50 0STORAGE LIFE HRS1544 MAX8986EWG+T
500150°C 80 0STORAGE LIFE HRS1545 MAX98706AEWV+TCLE
1000150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+
1000150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+
1000150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+
500150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+
500150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+
500150°C 77 0STORAGE LIFE HRS1545 MAX98304DEWL+
1000150°C 80 0STORAGE LIFE HRS1549 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1549 MAX77843EWV+T
1000150°C 77 0STORAGE LIFE HRS1551 MAX5394LANA+TCGS
1000150°C 77 0STORAGE LIFE HRS1551 MAX5394LANA+TCGS
1000150°C 80 0STORAGE LIFE HRS1604 MAX98721DEWV+TFA0
1000150°C 80 0STORAGE LIFE HRS1606 MAX98706AEWV+TCLE
500150°C 77 0STORAGE LIFE HRS1610 MAX5394LANA+TCGS
1000150°C 80 0STORAGE LIFE HRS1612 MAX98090AEWJ+T
1000150°C 77 0STORAGE LIFE HRS1612 MAX98304DEWL+
1000150°C 77 0STORAGE LIFE HRS1613 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX98304DEWL+
1000150°C 80 0STORAGE LIFE HRS1613 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1613 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1613 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1613 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1613 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1613 MAX98730EWJ+TCGT
1000150°C 80 0STORAGE LIFE HRS1613 MAX98730EWJ+TCGT
1000150°C 80 0STORAGE LIFE HRS1613 MAX98730EWJ+TCGT
1000150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+T
1000150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+
500150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+
500150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+
500150°C 77 0STORAGE LIFE HRS1613 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1614 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1614 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1614 MAX5394LANA+TCGS
1000150°C 77 0STORAGE LIFE HRS1614 MAX5394LANA+TCGS
1000150°C 77 0STORAGE LIFE HRS1616 MAX98304DEWL+T
1000150°C 77 0STORAGE LIFE HRS1616 MAX98304DEWL+
1000150°C 77 0STORAGE LIFE HRS1616 MAX98304DEWL+
1000150°C 77 0STORAGE LIFE HRS1616 MAX98304DEWL+
1000150°C 80 0STORAGE LIFE HRS1616 MAX98721DEWV+TFA0
500150°C 80 0STORAGE LIFE HRS1616 MAX98721DEWV+TFA0
500150°C 80 0STORAGE LIFE HRS1616 MAX98721DEWV+TFA0
1000150°C 80 0STORAGE LIFE HRS1616 MAX98721DEWV+TFA0
500150°C 80 0STORAGE LIFE HRS1616 MAX98721DEWV+TFA0
1000150°C 80 0STORAGE LIFE HRS1616 MAX98721DEWV+TFA0
1000150°C 50 0STORAGE LIFE HRS1616 MAX16124WTEQ00+G7
1000150°C 80 0STORAGE LIFE HRS1616 MAX98706AEWV+TCLE
500150°C 80 0STORAGE LIFE HRS1619 MAX98721DEWV+TFA0
1000150°C 80 0STORAGE LIFE HRS1619 MAX98721DEWV+TFA0
1000150°C 80 0STORAGE LIFE HRS1619 MAX98721DEWV+TFA0
500150°C 80 0STORAGE LIFE HRS1619 MAX98721DEWV+TFA0
1000150°C 80 0STORAGE LIFE HRS1619 MAX98721DEWV+TFA0
500150°C 80 0STORAGE LIFE HRS1620 MAX14709ENL+TCL7
500150°C 77 0STORAGE LIFE HRS1620 MAX77686EWE+
1000150°C 77 0STORAGE LIFE HRS1620 MAX77686EWE+
500150°C 77 0STORAGE LIFE HRS1621 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1621 MAX8986EWG+
1000150°C 80 0STORAGE LIFE HRS1621 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1621 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1621 MAX77843EWV+T
500150°C 80 0STORAGE LIFE HRS1621 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1621 MAX98730EWJ+TCGT
1000150°C 80 0STORAGE LIFE HRS1621 MAX98730EWJ+TCGT
500150°C 80 0STORAGE LIFE HRS1621 MAX98730EWJ+TCGT
1000150°C 80 0STORAGE LIFE HRS1621 MAX98730EWJ+TCGT
500150°C 77 0STORAGE LIFE HRS1621 MAX77686EWE+
1000150°C 77 0STORAGE LIFE HRS1621 MAX77686EWE+
1000150°C 77 0STORAGE LIFE HRS1621 MAX77686EWE+
500150°C 77 0STORAGE LIFE HRS1621 MAX77686EWE+
1000150°C 77 0STORAGE LIFE HRS1622 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1622 MAX8986EWG+
1000150°C 80 0STORAGE LIFE HRS1622 MAX98730EWJ+TCGT
1000150°C 80 0STORAGE LIFE HRS1622 MAX98730EWJ+TCGT
1000150°C 50 0STORAGE LIFE HRS1623 MAX16124WTEQ00+G7
500150°C 77 0STORAGE LIFE HRS1623 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1623 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1623 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1623 MAX8986EWG+
1000150°C 77 0STORAGE LIFE HRS1623 MAX8986EWG+
500150°C 80 0STORAGE LIFE HRS1623 MAX77843EWV+T
1000150°C 80 0STORAGE LIFE HRS1626 MAX98706AEWV+TCLE
500150°C 77 0STORAGE LIFE HRS1633 MAX77686EWG+T
500150°C 77 0STORAGE LIFE HRS1634 MAX77686EWG+T
1000150°C 77 0STORAGE LIFE HRS1634 MAX77686EWG+T
500150°C 50 0STORAGE LIFE HRS1636 MAX9027EWT+
0Total:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1436 MAX98721CEWV+TF90
144-65C TO +150C (Condition C) 100 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1520 MAX77838EWO+
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1529 MAX98730EWJ+CGT
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1544 MAX8986EWG+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1544 MAX8986EWG+T
1000-40C TO +125C (Condtion G) 55 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 55 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+T
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1545 MAX98304DEWL+
850-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1546 MAX98706AEWV+TCLE
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1550 MAX44265EWT+TCLX
1000-40C TO +125C (Condtion G) 55 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1551 MAX5394LANA+TCGS
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1551 MAX5394LANA+TCGS
835-40C TO +125C (Condtion G) 40 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1601 MAX8986EWG+
280-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1606 MAX98706AEWV+TCLE
1000-40C TO +125C (Condtion G) 55 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1610 MAX5394LANA+TCGS
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1610 MAX5394LANA+TCGS
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1610 MAX5394LANA+TCGS
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1610 MAX5394LANA+TCGS
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1612 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 75 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
1000-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX77843EWV+T
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+T
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX8986EWG+
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1613 MAX98706AEWV+TCLE
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX98304DEWL+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX98304DEWL+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX5394LANA+TCGS
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX5394LANA+TCGS
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX5394LANA+TCGS
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1614 MAX5394LANA+TCGS
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1615 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98304DEWL+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98304DEWL+T
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98304DEWL+
1000-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98721DEWV+TFA0
500-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98721DEWV+TFA0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98721DEWV+TFA0
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98721DEWV+TFA0
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98721DEWV+TFA0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98721DEWV+TFA0
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX16124WTEQ00+G7
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98706AEWV+TCLE
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1616 MAX98706AEWV+TCLE
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1619 MAX98721DEWV+TFA0
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1619 MAX98721DEWV+TFA0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1619 MAX98721DEWV+TFA0
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1619 MAX98721DEWV+TFA0
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1619 MAX98721DEWV+TFA0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1619 MAX98721DEWV+TFA0
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1620 MAX14709ENL+TCL7
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1620 MAX77910EWW+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1620 MAX77910EWW+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1620 MAX77686EWE+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77910EWW+
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+CGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX8986EWG+
250-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX8986EWG+
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77843EWV+T
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77843EWV+T
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77843EWV+T
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77843EWV+T
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77843EWV+T
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
1000-65C TO +150C (Condition C) 79 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1621 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
250-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
250-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX98730EWJ+TCGT
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77686EWE+
1000-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77686EWE+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1621 MAX77686EWE+
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX16124WTEQ00+G7
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730EWJ+
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730WEJ+CGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730EWJ+CGT
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730WEJ+CGT
1000-40C TO +125C (Condtion G) 76 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX8986EWG+
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730EWJ+TCGT
250-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1622 MAX98730EWJ+TCGT
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX8986EWG+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX8986EWG+
1000-40C TO +125C (Condtion G) 75 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX8986EWG+
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX8986EWG+
850-40C TO +125C (Condtion G) 76 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX8986EWG+
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX77843EWV+T
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1623 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1624 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1624 MAX98730EWJ+TCGT
1000-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98706AEWV+TCLE
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1626 MAX98706AEWV+TCLE
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98706AEWV+TCLE
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98706AEWV+TCLE
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1627 MAX98706AEWV+CLE
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1628 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1629 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1629 MAX98730EWJ+TCGT
500-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1633 MAX77686EWG+T
200-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1633 MAX98925EWV+T
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX77686EWG+T
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX9027EWT+
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1636 MAX9027EWT+
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1637 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1638 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1638 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1638 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1639 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1639 MAX98730EWJ+TCGT
100-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1640 MAX98730EWJ+TCGT
0Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
96130C, 85% R.H. 36 0BIASED MOISTURE HRS1436 MAX98721CEWV+TF90
100130C, 85% R.H. 67 0BIASED MOISTURE HRS1536 MAX14709ENL
96130C, 85% R.H. 36 0BIASED MOISTURE HRS1536 MAX14709ENL+
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1545 MAX98304DEWL+
110130C, 85% R.H. 77 0BIASED MOISTURE HRS1545 MAX98304DEWL+
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1551 MAX5394LANA+TCGS
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1606 MAX98706AEWV+TCLE
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1610 MAX98090AEWJ+T
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1610 MAX5394LANA+TCGS
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1610 MAX5394LANA+TCGS
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1612 MAX98090AEWJ+T
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1612 MAX98090AEWJ+T
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1612 MAX98730EWJ+TCGT
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1613 MAX98304DEWL+T
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1613 MAX98304DEWL+T
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1613 MAX98304DEWL+T
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1613 MAX77843EWV+T
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1613 MAX77843EWV+T
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1613 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1613 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1613 MAX98730EWJ+TCGT
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1613 MAX8986EWG+
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1613 MAX8986EWG+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1613 MAX98706AEWV+TCLE
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1614 MAX98304DEWL+T
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1614 MAX5394LANA+TCGS
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1614 MAX5394LANA+TCGS
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1616 MAX98304DEWL+T
264130C, 85% R.H. 68 0BIASED MOISTURE HRS1616 MAX98304DEWL+
264130C, 85% R.H. 68 0BIASED MOISTURE HRS1616 MAX98304DEWL+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1616 MAX98721DEWV+TFA0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1616 MAX98721DEWV+TFA0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1616 MAX98721DEWV+TFA0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1616 MAX16124WTEQ00+G7
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1616 MAX98706AEWV+TCLE
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1616 MAX98706AEWV+TCLE
48130C, 85% R.H. 36 0BIASED MOISTURE HRS1618 MAX14709ENL+TCL7
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1619 MAX98721DEWV+TFA0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1619 MAX98721DEWV+TFA0
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1619 MAX98721DEWV+TFA0
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1620 MAX77686EWE+
48130C, 85% R.H. 72 0BIASED MOISTURE HRS1621 MAX14709ENL+TCL7
48130C, 85% R.H. 72 0BIASED MOISTURE HRS1621 MAX14709ENL+TCL7
96130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730EWJ+CGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730WEJ+CGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX98730EWJ+TCGT
264130C, 85% R.H. 79 0BIASED MOISTURE HRS1621 MAX98730EWJ+TCGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX77686EWE+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1621 MAX77686EWE+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1622 MAX16124WTEQ00+G7
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1622 MAX98730WEJ+CGT
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1622 MAX98730WEJ+CGT
264130C, 85% R.H. 76 0BIASED MOISTURE HRS1622 MAX8986EWG+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1622 MAX98730EWJ+TCGT
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1623 MAX8986EWG+
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1626 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1626 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1627 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0BIASED MOISTURE HRS1627 MAX98706AEWV+TCLE
264130C, 85% R.H. 77 0BIASED MOISTURE HRS1634 MAX77686EWG+T
0Total:
UNBIASED MOISTURE RESISTANCE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
100085 C/85% R.H. 77 0MOISTURE SOAK HRS1521 MAX77838EWO+
100085 C/85% R.H. 74 0MOISTURE SOAK HRS1522 MAX77838EWO+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1529 MAX98730EWJ+CGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1544 MAX8986EWG+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1545 MAX98304DEWL+
100085 C/85% R.H. 80 0MOISTURE SOAK HRS1549 MAX77843EWV+T
100085 C/85% R.H. 78 0MOISTURE SOAK HRS1551 MAX77900EWNX000+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1606 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1612 MAX98090AEWJ+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1612 MAX98090AEWJ+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1612 MAX98730EWJ+TCGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1612 MAX98304DEWL+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX98304DEWL+
1000130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX77843EWV+T
100085 C/85% R.H. 80 0MOISTURE SOAK HRS1613 MAX77843EWV+T
1000130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX77843EWV+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX77843EWV+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX77843EWV+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX77843EWV+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX98730EWJ+TCGT
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX98730EWJ+TCGT
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX98730EWJ+TCGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX8986EWG+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX8986EWG+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX8986EWG+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX8986EWG+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1613 MAX8986EWG+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1613 MAX98706AEWV+TCLE
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1614 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1614 MAX98304DEWL+T
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1614 MAX5394LANA+TCGS
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1614 MAX5394LANA+TCGS
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1615 MAX98730EWJ+TCGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1616 MAX98304DEWL+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1616 MAX98304DEWL+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1616 MAX98721DEWV+TFA0
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1616 MAX98721DEWV+TFA0
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1616 MAX98721DEWV+TFA0
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1616 MAX16124WTEQ00+G7
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1619 MAX98721DEWV+TFA0
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1619 MAX98721DEWV+TFA0
100130C, 85% R.H. 77 0MOISTURE SOAK HRS1619 MAX98721DEWV+TFA0
130130C, 85% R.H. 80 0MOISTURE SOAK HRS1620 MAX14709ENL+TCL7
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1620 MAX77686EWE+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX77843EWV+T
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX77843EWV+T
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX77843EWV+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX77843EWV+T
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX77843EWV+T
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX98730EWJ+TCGT
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX98730EWJ+TCGT
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX98730EWJ+TCGT
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1621 MAX98730EWJ+TCGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1621 MAX77686EWE+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1621 MAX77686EWE+
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1622 MAX16124WTEQ00+G7
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1622 MAX98730EWJ+TCGT
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1622 MAX98730EWJ+TCGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1623 MAX8986EWG+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1623 MAX8986EWG+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1623 MAX8986EWG+
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1623 MAX8986EWG+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1623 MAX77843EWV+T
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1623 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1623 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1623 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1624 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1626 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98706AEWV+TCLE
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98706AEWV+TCLE
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1627 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1628 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1629 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1629 MAX98730EWJ+TCGT
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1633 MAX77686EWG+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1634 MAX77686EWG+T
96130C, 85% R.H. 77 0MOISTURE SOAK HRS1634 MAX77686EWG+T
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1636 MAX9027EWT+
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1638 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1638 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1638 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1639 MAX98730EWJ+TCGT
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1640 MAX98730EWJ+TCGT
0Total:
Package Type: WLP-HC (Pb-Free)
Assembly Information:
16341551 toDate Code Range:
TEMPERATURE CYCLE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
144-40C TO +125C (Condtion G) 78 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1608 MAX15053EWL+TCN1
850-65C TO +150C (Condition C) 120 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1608 MAX15053EWL+TCN1
500-40C TO +125C (Condtion G) 120 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1608 MAX15053EWL+CN1
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1608 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 78 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1608 MAX15053EWL+TCN1
500-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1608 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1608 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 77 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1618 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1618 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 199 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1633 MAX15053EWL+TCN1
144-40C TO +125C (Condtion G) 200 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1633 MAX15053EWL+TCN1
1000-65C TO +150C (Condition C) 190 0TEMP CYCLE, 5' RAMP, 10' DWELL
CYS1633 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 80 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1633 MAX15053EWL+TCN1
850-40C TO +125C (Condtion G) 79 0TEMP CYCLE, 15' RAMP, 15' DWELL
CYS1634 MAX15053EWL+TCN1
0Total:
TEMPERATURE HUMIDITY BIAS
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1551 MAX15053EWL+CN1
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1605 MAX15053EWL+CN1
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1608 MAX15053EWL+TCN1
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1608 MAX15053EWL+TCN1
264130C, 85% R.H. 80 0BIASED MOISTURE HRS1633 MAX15053EWL+TCN1
0Total:
UNBIASED MOISTURE RESISTANCE
DESCRIPTION READPOINTCONDITION QUANTITY FAILSDATE
CODE
FA NOTEST
VEHICLE
264130C, 85% R.H. 80 0MOISTURE SOAK HRS1551 MAX15053EWL+CN1
264130C, 85% R.H. 80 0MOISTURE SOAK HRS1605 MAX15053EWL+CN1
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1608 MAX15053EWL+TCN1
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1608 MAX15053EWL+CN1
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1608 MAX15053EWL+TCN1
100130C, 85% R.H. 78 0MOISTURE SOAK HRS1608 MAX15053EWL+TCN1
100130C, 85% R.H. 80 0MOISTURE SOAK HRS1608 MAX15053EWL+TCN1
96130C, 85% R.H. 80 0MOISTURE SOAK HRS1633 MAX15053EWL+TCN1
0Total:
FAILURE RATE: MTTF (YRS): 1141552 FITS: 0.1