Page 1: WALL MOUNT RANGE HOOD SPECIFICATIONS

VP562/VP563transition

centers outlet over top of hood

WALL MOUNT RANGE HOOD SPECIFICATIONSDA18/DAH18/PWV18/PWVH18/XR18/XRH18/XRX18/XRXH18 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models. X in part number indicates 27" depth.

*Exceeding recommended mounting height may

compromise performance.

900 CFM B200 Dual & B100 Single Blower(Top View)

1200 CFM Double B200 Dual Blowers(Top View)

6” Outlet

VentHole

3 ¼”

Electrical

Centerlineof Hood

Wall Side

1 ¾”1 �⁄�”5 ¼”

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

8” Outlet6” Outlet

5 ¼”

Wall Side

VentHoles

Centerlineof Hood

Electrical (2)

5 ½”

7 �⁄��”

1 �⁄�”

7 �⁄��”1 ¾”

11” 11”

5 ½” 5 ½” Wall Side

5 ¼”1 ¾”

Electrical (2)8” Outlet

VentHoles

8” Outlet

Centerlineof Hood

10” Round 10” Round

8” Round

17 ½”

2”

8” Round 6” Round

12” Round 12” Round

16 ½”

8” Round 8” Round8” Round3”

VP562 Transition (Optional) For B300(B200 Dual Blower & B100 Single Blower)

VP563 Transition (Optional) For B400(Double B200 Dual Blowers)

Connection Diagrams (30” - 48” Widths) RecommendedMounting Height*

ULC USR

10” OR 12”Round

DA18/DAH18 PWV18/PWVH18 XR(X)18/XR(X)H18

300 CFM B100 Single Blower(Top View)

600 CFM B200 Dual Blower(Top View)

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6

* Add2.5ampforeachwarminglightand0.5ampforeachhalogenlight.Hoodsareavailablewithfluorescentlight(oneforeachsingleordualblower)orwithhalogenlights(2lights:30"-41",3lights:42"-53",4lights:54"-66",+1lightforeach14"ifover66").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0210A

Connection Diagram (42” - 60" Widths)

Connection Diagram (48” - 66" Widths)

Page 2: WALL MOUNT RANGE HOOD SPECIFICATIONS

WALL MOUNT RANGE HOOD SPECIFICATIONSCX30/CXH30/DA30/DAH30/PWV30/PWVH30/SL30/SLH30 “H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models.

*Exceeding recommended mounting height may

compromise performance.

VP562/VP563transition

centers outlet over top of hood

900 CFM B200 Dual & B100 Single Blower(Top View)

1200 CFM Double B200 Dual Blowers(Top View)

6” Outlet

VentHole

3 ¼”

Electrical

Centerlineof Hood

Wall Side

1 ¾”1 �⁄�”5 ¼”

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

8” Outlet6” Outlet

5 ¼”

Wall Side

VentHoles

Centerlineof Hood

Electrical (2)

5 ½”

7 �⁄��”

1 �⁄�”

7 �⁄��”1 ¾”

11” 11”

5 ½” 5 ½” Wall Side

5 ¼”1 ¾”

Electrical (2)8” Outlet

VentHoles

8” Outlet

Centerlineof Hood

10” Round 10” Round

8” Round

17 ½”

2”

8” Round 6” Round

12” Round 12” Round

16 ½”

8” Round 8” Round8” Round3”

VP562 Transition (Optional) For B300(B200 Dual Blower & B100 Single Blower)

VP563 Transition (Optional) For B400(Double B200 Dual Blowers)

ULC USR

Connection Diagrams (30” - 48” Widths) RecommendedMounting Height*

10” OR 12”Round

CX30/CXH30 DA30/DAH30 PWV30/PWVH30 SL30/SLH30

300 CFM B100 Single Blower(Top View)

600 CFM B200 Dual Blower(Top View)

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6

* Add2.5ampforeachwarminglightand0.5ampforeachhalogenlight.Hoodsareavailablewithfluorescentlight(oneforeachsingleordualblower)orwithhalogenlights(2lights:30"-41",3lights:42"-53",4lights:54"-66",+1lightforeach14"ifover66").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A

Connection Diagram (42” - 60" Widths)

Connection Diagram (48” - 66" Widths)

Page 3: WALL MOUNT RANGE HOOD SPECIFICATIONS

WALL MOUNT RANGE HOOD SPECIFICATIONSCW/CWH “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected models.

CW/CWH

Connection Diagrams (30” - 48” Widths)

VP562/VP563transition

centers outlet over top of hood

*Exceeding recommended mounting height may

compromise performance.900 CFM B200 Dual & B100 Single Blower

(Top View)

1200 CFM Double B200 Dual Blowers(Top View)

6” Outlet

VentHole

3 ¼”

Electrical

Centerlineof Hood

Wall Side

1 ¾”1 �⁄�”5 ¼”

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

8” Outlet6” Outlet

5 ¼”

Wall Side

VentHoles

Centerlineof Hood

Electrical (2)

5 ½”

7 �⁄��”

1 �⁄�”

7 �⁄��”1 ¾”

11” 11”

5 ½” 5 ½” Wall Side

5 ¼”1 ¾”

Electrical (2)8” Outlet

VentHoles

8” Outlet

Centerlineof Hood

10” Round 10” Round

8” Round

17 ½”

2”

8” Round 6” Round

12” Round 12” Round

16 ½”

8” Round 8” Round8” Round3”

VP562 Transition (Optional) For B300(B200 Dual Blower & B100 Single Blower)

VP563 Transition (Optional) For B400(Double B200 Dual Blowers)

ULC USR

RecommendedMounting Height*

10” OR 12”Round

300 CFM B100 Single Blower(Top View)

600 CFM Dual Blower(Top View)

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6

* Add2.5ampforeachwarminglightand0.5ampforeachhalogenlight.Hoodisavailablewithfluorescentlight(oneforeachsingleordualblower)orwithhalogenlights(2lights:30"-41",3lights:42"-53",4lights:54"-66",+1lightforeach14"ifover66").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0210A

Connection Diagram (42” - 60" Widths)

Connection Diagram (48” - 66" Widths)

Page 4: WALL MOUNT RANGE HOOD SPECIFICATIONS

24 ¼

11 ¼”

WIDTH

8 ¼”

Hinge 1” From Top

Cut Out For Top Vent

Mounting HolesFor Door Panel

Cut Out For Back Vent

WALL MOUNT RANGE HOOD SPECIFICATIONSTLH (Halogen Lights) Not available with heat lamps.TILT (Fluorescent Light) Not available with heat lamps.

TLH/TILT

300 CFM B100 Single Blower(Top View)

600 CFM B200 Dual Blower(Top View)

*Exceeding recommended mounting height may

compromise performance.

6” Outlet

VentHole

3 ¼”

Electrical

Centerlineof Hood

Wall Side

1 ¾”1 �⁄�”5 ¼”

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

Connection Diagrams (30” - 48” Widths) RecommendedMounting Height*

ULC USR

24 ¼”

21o Bevel Minimum1 ¼” Long¼” Or Less

Door Panel Specifications

Door Panel Must BeSupplied By Cabinet Maker

Door Panel CanOverhang

13 ½

”10

¾”

24 ¼

11 ¼”Left End

Channel For Mounting Strip

13 ½

”10

¾”

24 ¼

Back View of Hood

12 ½”Cut Out For Back Vent

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5

* Add0.5ampforeachhalogenlight.Hoodisavailablewithasinglefluorescentlightorwithhalogenlights(2lights:30"-41",3lights:42"-48").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0409A

Page 5: WALL MOUNT RANGE HOOD SPECIFICATIONS

VP562/VP563transition

centers outlet over top of hood

WALL MOUNT RANGE HOOD SPECIFICATIONS

*Exceeding recommended mounting height may

compromise performance.

Connection Diagram (42” - 60" Widths)

Connection Diagram (48” - 66" Widths)

900 CFM B200 Dual & B100 Single Blower(Top View)

1200 CFM Double B200 Dual Blowers(Top View)

6” Outlet

VentHole

3 ¼”

Electrical

Centerlineof Hood

Wall Side

1 ¾”1 �⁄�”5 ¼”

Electrical

1 ¾”

Centerlineof Hood

8” Outlet

VentHoles

5 ¼”5 ½”Wall Side

8” Outlet6” Outlet

5 ¼”

Wall Side

VentHoles

Centerlineof Hood

Electrical (2)

5 ½”

7 �⁄��”

1 �⁄�”

7 �⁄��”1 ¾”

11” 11”

5 ½” 5 ½” Wall Side

5 ¼”1 ¾”

Electrical (2)8” Outlet

VentHoles

8” Outlet

Centerlineof Hood

10” Round 10” Round

8” Round

17 ½”

2”

8” Round 6” Round

12” Round 12” Round

16 ½”

8” Round 8” Round8” Round3”

VP562 Transition (Optional) For B300(B200 Dual Blower & B100 Single Blower)

VP563 Transition (Optional) For B400(Double B200 Dual Blowers)

Connection Diagrams (30” - 48” Widths) RecommendedMounting Height*

ULC USR

10” OR 12”Round

300 CFM B100 Single Blower(Top View)

600 CFM B200 Dual Blower(Top View)

NP18/NPH18/NPX18/NPXH18/PR18/PRH18/PRX18/PRXH18/SL18/SLH18/SLX18/SLXH18“H” in part number indicates halogen lighting. WBAR warming light bar is available on selected models (included on NP Series). X in part number indicates 27” depth.

NP(X)18/NP(X)H18(Includes WBAR warming light bar)

PR(X)18/PR(X)H18 SL(X)18/SL(X)H18

Electrical/Mechanical Specifications For Blower Units

Model Volts Amps* Hz RPM [email protected]" Equivalent CFM• CFM

[email protected]"CFM

[email protected]"CFM

[email protected]"Minimum Round

Duct Size Sones#

B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.2) 5.4B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.2) 6.5B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.2) 6.3Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.2) 6.6

* Add2.5ampforeachwarminglightand0.5ampforeachhalogenlight.Hoodsareavailablewithfluorescentlight(oneforeachsingleordualblower)orwithhalogenlights(2lights:30"-41",3lights:42"-53",4lights:54"-66",+1lightforeach14"ifover66").• BecausetheMagicLung®blowerusescentrifugalfiltrationratherthanconventionalbaffleormeshfilters,theMagicLung®blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmoreefficientlythanotherthanotherfiltrationsystems.WhencomparingtheMagicLung®withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.

# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A


Recommended