Victron Products
Chargers / Powersuply’s
Inverter / Multies
Isolation transformers
DC / DC converters
Panels / battery monitors
Battery isolators / batytery’s
Solar products
Chargers
12 / 24 / 48 VDC
Must is multi voltage 90 to 265VAC
Must can run on DC voltage 90 to 400VDC
Must can be used as power suply
Multi outputs
Some have voltage / temp. sensor
Inverters
Inverters from 12VDC , 24VDC and 48VDC to 230VAC and 400VAC
Inverters from 12VDC and 24VDC to 120VAC 60Hz.
All inverters have pure sinewave.
All inverters have extra start up power.
All have possibility for remote control.
All VE-Bus units can be parallel and 3 phase up to 30 units.
Programable relay used by VE.Cof. Software (build in)
From 180VA to 5KVA.
Multis and Quattros
Same features as inverters but also :
Powerfull charger 16A to 220A.
Power controll.
Power assistent.
Used with solar system both Grid and Off Grid.
Big Multis have 2 outputs (1 break and 1 No-break).
Quattros have 2 in-put and 2 out-put.
2 in-put gives a intergrated transfer switch.
From 800VA to 10KVA
Transfer switch from 16A to 100A
AC POWER MANAGEMENT
Primary supply
(generator or shore)
Supply to on board
consumers
Energy converted
to charge batteriesUnder normal conditions,
there is sufficient power to
supply load and charge
batteries.Battery
Phoenix Multi
AC POWER MANAGEMENT
Primary supply
(generator or shore)
Supply to on board
consumers
Less energy
converted to
charge batteries
As demand from on board
consumers increases,
power used to charge
batteries is reducedBattery
Phoenix Multi
AC POWER MANAGEMENT
Primary supply
(generator or shore)
Supply to on board
consumers
Energy drawn
from batteriesWhen demand from
consumers exceeds
capacity of supply, energy
is drawn from battery to
assist shore/generatorBattery
Phoenix Multi
AC POWER MANAGEMENT
Primary supply
(generator or shore)
Supply to on board
consumers
Energy converted
to charge batteriesWhen peak in demand
has reduced, system
returns to normal
operation and the power
used from battery is
replaced.
Battery
Phoenix Multi
MULTIPlus SYSTEM EXAMPLE
Phoenix
MultiPlus
3kVA /
70A
4kVA
generator0.5kVA4kVA
Micro. 1.8kVA
Others 1kVA
Battery
1.5
kVA
Air-Con B 1.5kVA
(5kVA start)
Normal conditions, there is enough power available for
charger to operate at full power.
MULTIPlus SYSTEM EXAMPLE
Phoenix
MultiPlus
3kVA /
70A
4kVA
generator2.8kVA4kVA
Micro 1.8kVA
Others 1kVA
Battery
1.2
kVA
Air-Con B 1.5kVA
(5kVA start)
Consumption by consumers increases so
charger backs off to compensate.
MULTIPlus SYSTEM EXAMPLE
Phoenix
MultiPlus
3kVA /
70A
4kVA
generator
8kVA4kVA
Air-Con B 1.5kVA
(5kVA start)
Micro 1.8kVA
Others 1kVA
Battery
4.0
kVA
When air-con starts, max load may be,
say,8kVA. Multi immediately provides the extra
power required to start compressor.
MULTIPlus SYSTEM EXAMPLE
Phoenix
MultiPlus
3kVA /
70A
4kVA
generator4.3kVA4kVA
Air-Con B 1.5kVA
(5kVA start)
Micro 1.8kVA
Others 1kVA
Battery
0.3
kVA
Once Air-Con. Has started, total load reduces to
4.3kVA, still too much for generator alone.
MULTIPlus SYSTEM EXAMPLE
Phoenix
MultiPlus
3kVA /
70A
4kVA
generator2.5kVA4kVA
Micro. 1.8kVA
Others 1kVA
Battery
1.5
kVA
Air-Con B 1.5kVA
(5kVA start)
Some consumers are switched off and system
returns to normal. Charger re charge what was
taken from the battery.
Other products
Isolations transformers
Auto transformer (for US use 240VAC splitphase)
DC-DC converters non isolated and galvanic isolated.
Automatis transfer switches.
Batteri monitors.
System manager E-plex and system panels
Global remote
Battery isolators.
Battery protection
Shore power cables
Alternators and batteries.
GSM network
Schematic Overview
System state: inverter
Alarms: none.
Warnings: Low Battery.
Battery: 22.35V
122.11A
In: 0.00V 0.00A 0.00Hz
Out: 230.47V 10.42A
49.89Hz
SMS
GPRS
http://www.victronenergy.com/
All essential information is shown in values and in a graph
•State of the system•All information on Voltage and
Current ( AC and DC )
•When a battery monitor is connected the SOC will be shown
•http://vrm.victronenergy.com/beurs.php
New in 2010/2011
Main systems will be with NMEA2000.
New design on units will start in 2010 on Multi serie.
Bigger Quattros 12/5000 , 24/8000 , 48/10000 will be ready.
New Lynx DC distributions system (1000A).
Global remote IO-extender (2 digital output and 3 digital input).
New generation of control panels.
Units will be IP22 in the new design.