Design Standards
Standard Specifications
STATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
CONTRACT PLANS
HAVE CHANGED DUE TO REPRODUCTION.
NOTE: THE SCALE OF THESE PLANS MAY
P.E. NO.:
ENGINEER OF RECORD:
SHEET DESCRIPTIONSHEET NO.
TO BE SUBMITTED TO:
NO.
SHEET
YEAR
FISCAL
9:59:27 AM \\TMAW00\jobs\63045\CADD\TWO7\its\District 5\keysit02_D5.dgntsheppard 2/16/2017
FINANCIAL PROJECT ID 440222-1-52-01
(FEDERAL FUNDS)
FDOT PROJECT MANAGER:
DESCRIPTIONDATE
KEY SHEET REVISIONS
BEE LINEEXPRESSWAY
TU
RNPIK
E
10
PENSACOLA FORT WALTON
BEACH
PANAMACITY
CHIPLEY
TALLAHASSEE
75
10
295
95
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA DAYTONA BEACH
DELAND4
NEW PORT RICHEY
TAMPA
754
LAKELAND
MELBOURNE -COCOA
ORLANDO
BARTOWST PETERSBURG
275
SARASOTA -
BRADENTON
75
95
FT PIERCE
FT MYERS
WEST PALM
BEACH
FT LAUDERDALE
MIAMI
75
75
NAPLES
KEY WEST
CITY
LAKE
following web site:
For Design Standards click on the "Design Standards" link at the
click on the "Specifications" link at the following web site:
For the Standard Specifications for Road and Bridge Construction
GOVERNING STANDARDS AND SPECIFICATIONS:
http://www.dot.state.fl.us/rddesign/
http://www.dot.state.fl.us/specificationsoffice/
Contract Documents.
Specifications for Road and Bridge Construction, as amended by
revised Index Drawings as appended herein, and 2017 Standard
Florida Department of Transportation, 2017 Design Standards and
FLO
RID
A'S
ITS SHOP DRAWINGS
INTERSTATE
75
INTERSTATE
10
1
INDEX OF TPAS PLANS
STYSTEMS (TPAS) PLANS
TRUCK PARKING AVAILABILITY
INTELLIGENT TRANSPORTATION SYSTEM PLANS
TRUCK PARKING AVAILABILITY SYSTEMS (TPAS)
IT-01 TO IT-05A
3
2
1
ITS PLAN SHEETS
GUIDESIGN WORKSHEET
GENERAL NOTES
KEY SHEET
30% PLANS PREPARED BY:
50192 SOUTHBOUND (MILE MARKER 308)
50191 NORTHBOUND (MILE MARKER 307)
SUMTER COUNTY, REST AREAS
50662 SOUTHBOUND (MILE MARKER 338)
50661 NORTHBOUND (MILE MARKER 338)
MARION COUNTY, WEIGH STATIONS
50182 SOUTHBOUND (MILE MARKER 346)
50181 NORTHBOUND (MILE MARKER 345)
MARION COUNTY, REST AREAS
16
INTERSTATE
75
INTERSTATE
4
INTERSTATE
95
PURPOSE ONLYFOR ILLUSTRATION
50192 SOUTHBOUND (MILE MARKER 308)
50191 NORTHBOUND (MILE MARKER 307)
SUMTER COUNTY, REST AREAS
50662 SOUTHBOUND (MILE MARKER 338)
50661 NORTHBOUND (MILE MARKER 338)
MARION COUNTY, WEIGH STATIONS
50182 SOUTHBOUND (MILE MARKER 346)
50181 NORTHBOUND (MILE MARKER 345)
MARION COUNTY, REST AREAS
PURPOSE ONLYFOR ILLUSTRATION
50192 SOUTHBOUND (MILE MARKER 308)
50191 NORTHBOUND (MILE MARKER 307)
SUMTER COUNTY, REST AREAS
50662 SOUTHBOUND (MILE MARKER 338)
50661 NORTHBOUND (MILE MARKER 338)
MARION COUNTY, WEIGH STATIONS
50182 SOUTHBOUND (MILE MARKER 346)
50181 NORTHBOUND (MILE MARKER 345)
MARION COUNTY, REST AREAS
PURPOSE ONLYFOR ILLUSTRATION
2/16/2017tsheppard \\TMAW00\jobs\63045\CADD\TWO7\its\District 5\gnntit01.DGN9:59:39 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
GENERAL NOTES
VARIES VARIES 2
GENERAL NOTES
RR
DMS
CCTV WITH POLE
MVDS
ACCESS POINT
REPEATER
GROUND SENSORS
DETECTION ZONE
BASE MOUNT CABINET
POLE MOUNT CABINET
PULL BOX
FIBER OPTIC PULL BOX
SPLICE VAULT
POWER SERVICE
POLE
DMS
CONDUIT, OPEN TRENCH
CONDUIT, DIRECTIONAL BORE
FIBER OPTIC RUN
POWER RUN
PROPOSEDEXISTING
LEGEND
UTILITY OWNERS UTILITY OWNERS (CONTINUED)
8.
7.
6.
5.
4.
3.
2.
1.
MULTI-POST STATIC SIGN W/ ELECTRICAL DISPLAY SIGN
[email protected] 352-538-5739RYAN COULTERFDOT DISTRICT 5
[email protected] X3139DON TAULBEEWITHLACOOCHEE RIVER ELECTRIC COOP
[email protected] PATELTRANSCORE
[email protected] cell904-739-4874352-622-0111CHRIS URIATECO PEOPLES GAS OCALA
[email protected] COTTRELLSUMTER ELECTRIC COOPERATIVE INC
352-438-2381MARK WILLIAMSMARION COUNTY UTILITIES
[email protected] SCRIBBENFLORIDA PUBLIC UTILITIES
352-267-4931352-759-2788WAYNEFLORIDA CABLE INC
[email protected] SMITHCENTURY LINK - OCALA
[email protected] X212BEN ARDILESCABLEVISION OF MARION COUNTY
[email protected] WOLSKIBRIGHT HOUSE NETWORKS (MARION)
CONFLICTS SHALL BE REPORTED TO THE PROJECT ENGINEER IMMEDIATELY.UTILITIES ARE IN CONFLICT PRIOR TO USE OF A MECHANICAL AUGER. ANY POTENTIAL THE CONTRACTOR SHALL HAND DIG (SOFT DIG) TO A DEPTH OF FOUR (4) FEET WHERE
ELECTRICAL POWER SERVICE METERS SHALL HAVE A SEPARATE BREAKER FOR EACH ITS CIRCUIT.
INSTALLATION AND AFTER FINAL INSTALLATION.THE CONDUIT SHALL BE SEALED WITH THE SPECIFIED DUCT PLUG AT THE TIME OF CONDUIT
TEMPLATE SHALL BE PROVIDED FOR REVIEW.TUBULAR ROUTE MARKERS PER THE FDOT STANDARD SPECIFICATIONS. A MARKER LABEL THE CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ABOVE GROUND
AND IN ACCORDANCE WITH ALL FDOT STANDARDS FOR CONDUIT INSTALLATION. INSTALL FIBER OPTIC CONDUIT FOR COMMUNICATION TO DEVICES AS SHOWN IN THE PLANS
EXTENDED.THE PULL BOXES AND CONDUIT SUPPORTING THAT DEVICE SHALL BE RELOCATED AND/OR RELOCATION BY THE PROJECT ENGINEER. IF DEVICE RELOCATIONS OCCUR FOR ANY REASON, THE DEVICE THEY SUPPORT. ITS DEVICE LOCATIONS ARE APPROXIMATE AND MAY REQUIRE FIBER OPTIC AND POWER PULL BOXES AND CONDUIT SHALL BE LOCATED WITHIN 100 FEET OF
SITE.OF FLORIDA (811) TWO BUSINESS DAYS IN ADVANCE OF BEGINNING CONSTRUCTION ON THE JOB THE CONTRACTOR SHALL NOTIFY UTILITY OWNERS LISTED THROUGH SUNSHINE STATE ONE CALL
CONSIDERED APPROXIMATE ONLY.INVESTIGATION TECHNIQUES, AND MARK-UPS FROM UTILITY OWNERS. ALL UTILITIES SHOULD BE THE LOCATION(S) OF THE UTILITIES SHOWN IN THE PLANS ARE BASED ON LIMITED
2/16/2017tsheppard \\TMAW00\jobs\63045\CADD\TWO7\its\District 5\gswksp01.dgn9:59:44 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
VARIES VARIES
GUIDESIGN WORKSHEET
3
15.5" 155" 15.5"
15'-6"
9"
12"EM
9"
12"EM
9"
22"
8"
12"D
9"
8'-
6"
15.5" 155" 15.5"
15'-6"
9"
12"EM
9"
12"EM
9"
22"
8"
12"D
9"
8'-
6"
SPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
SPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACESPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
SPACE
COPY COPY
SPACE
SPACE
COPY
SPACE
COPY
SYMBOL(S) X Y WID HTANGLE
SIGN NAME STATION(S)
WIDTH
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
NUMBER
SIGN
QTY
SIGN
NUMBER
CLEARANCE COLUMN SIZE AVERAGE
LENGTH
Edge Of Lane
NUMBER
OF POSTS
SYMBOL(S) X Y WID HTANGLE
SIGN NAME STATION(S)
WIDTH
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
NUMBER
SIGN
QTY
SIGN
NUMBER
CLEARANCE COLUMN SIZE AVERAGE
LENGTH
Edge Of Lane
NUMBER
OF POSTS
SYMBOL(S) X Y WID HTANGLE
SIGN NAME STATION(S)
WIDTH
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
NUMBER
SIGN
QTY
SIGN
NUMBER
CLEARANCE COLUMN SIZE AVERAGE
LENGTH
Edge Of Lane
NUMBER
OF POSTS
SYMBOL(S) X Y WID HTANGLE
SIGN NAME STATION(S)
WIDTH
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
NUMBER
SIGN
QTY
SIGN
NUMBER
CLEARANCE COLUMN SIZE AVERAGE
LENGTH
Edge Of Lane
NUMBER
OF POSTS
FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE
FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE
REST 1
15'-6" 2"
none
8'-6" 12"
White White
Blue
40.7
R
12.2
E
11
S
11.5
T
8.9
12
A
14.3
R
12.2
E
10.2
A
12.1 40.7
L
104.5
19.4
T
11
R
12.2
U
12.6
C
12.4
K
9.8
12
P
10.7
A
14.3
R
12.2
K
11.8
I
5.8
N
12.6
G
9.7 19.4
L
147.1
15.5
S
10.2
P
8.9
A
11.8
C
10.8
E
8.6
S
8.2
12
A
10.9
V
9.8
A
12
I
4.8
L
8.2
A
12
B
10.2
L
9.2
E
7.4 15.5
L
155
DMS 72.7 29 44 220
WEIGH 1
15'-6" 2"
none
8'-6" 12"
White White
Blue
23.3
W
14.9
E
11.4
I
5.3
G
12.6
H
9.7
12
S
11.5
T
9.8
A
13.1
T
11
I
5.3
O
13
N
9.7 23.3
L
139.3
19.4
T
11
R
12.2
U
12.6
C
12.4
K
9.8
12
P
10.7
A
14.3
R
12.2
K
11.8
I
5.8
N
12.6
G
9.7 19.4
L
147.1
15.5
S
10.2
P
8.9
A
11.8
C
10.8
E
8.6
S
8.2
12
A
10.9
V
9.8
A
12
I
4.8
L
8.2
A
12
B
10.2
L
9.2
E
7.4 15.5
L
155
DMS 72.7 29 44 220
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT01.DGN9:59:59 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 242626-2-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 NB
I-75 SB
NORTHBOUND MILE MARKER 307
REST AREA 50191 (44 SPACES)
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-01I-75 SUMTER
ITS FIBER TRUNKLINE (EXISTING)
R/W LINE
ELECTRIC PULL BOX (TYP.)
FIBER OPTIC SPLICE VAULT
(EXISTING)
FIBER PULL BOX (TYP.)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
ELECTRICAL PULL BOX (TYP.)
(EXISTING)
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
FIBER OPTIC PULL BOX (TYP.)(EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
ITS POWER SERVICE DROP (TYP.)(EXISTING)
SEE SHEET IT-02 FOR DETAILS
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
ITS POWER SERVICE
SUPPLIED FROM THE EXISTING
120/240 VAC SINGLE PHASE POWER
FIBER SPLICE VAULTINTERCEPT EXISTING
ENTERING INTO EXISTING CABINET
CABLE USING EXISTING CONDUIT
INSTALL NEW COMMUNICATION
8 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- SPARE
- POWER
2-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
2-2" CONDUIT (DIRECTIONAL BORE)
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 2-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
- FPID 242626-2-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 NB
I-75 SB
NORTHBOUND MILE MARKER 307
REST AREA 50191 (44 SPACES)
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-01I-75 SUMTER
ITS FIBER TRUNKLINE (EXISTING)
R/W LINE
ELECTRIC PULL BOX (TYP.)
FIBER OPTIC SPLICE VAULT
(EXISTING)
FIBER PULL BOX (TYP.)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
ELECTRICAL PULL BOX (TYP.)
(EXISTING)
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
FIBER OPTIC PULL BOX (TYP.)(EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
ITS POWER SERVICE DROP (TYP.)(EXISTING)
SEE SHEET IT-02 FOR DETAILS
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
ITS POWER SERVICE
SUPPLIED FROM THE EXISTING
120/240 VAC SINGLE PHASE POWER
FIBER SPLICE VAULTINTERCEPT EXISTING
ENTERING INTO EXISTING CABINET
CABLE USING EXISTING CONDUIT
INSTALL NEW COMMUNICATION
8 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- SPARE
- POWER
2-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
2-2" CONDUIT (DIRECTIONAL BORE)
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 2-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT02.DGN10:00:18 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 242626-2-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 NB
I-75 SB
SOUTHBOUND MILE MARKER 308
REST AREA 50192 (32 SPACES)
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-02I-75 SUMTER
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
R/W LINE
SEE SHEET IT-01 FOR DETAILS
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- FPID 242626-2-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 NB
I-75 SB
SOUTHBOUND MILE MARKER 308
REST AREA 50192 (32 SPACES)
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-02I-75 SUMTER
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
R/W LINE
SEE SHEET IT-01 FOR DETAILS
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
2/16/2017tsheppard \\Tmaw00\pmwork\jobs\63045\CADD\TWO7\its\District 5\PLANIT02A.DGN5:03:00 PM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 242626-2-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDNORTH OF REST AREA 50192 (MM 308)3-DIGIT EMBEDDED DMS AT SB MM 312.20TRUCK PARKING AVAILABILITY SIGN WITH
SOUTHBOUND MILE MARKER 312.20
TPAS SIGN 50192
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-02AI-75 SUMTER
N
LOCATOR
INTERSTATE
75
98 301
50
SB MM 30850192
REST AREA
EXIT 301
SB MM 312.20VMS 50192
FIBER SPLICE VAULT
INTERCEPT EXISTING
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (DIRECTIONAL BORE)
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
POWER PULL BOX
INTERCEPT EXISTING
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- FPID 242626-2-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDNORTH OF REST AREA 50192 (MM 308)3-DIGIT EMBEDDED DMS AT SB MM 312.20TRUCK PARKING AVAILABILITY SIGN WITH
SOUTHBOUND MILE MARKER 312.20
TPAS SIGN 50192
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-02AI-75 SUMTER
N
LOCATOR
INTERSTATE
75
98 301
50
SB MM 30850192
REST AREA
EXIT 301
SB MM 312.20VMS 50192
FIBER SPLICE VAULT
INTERCEPT EXISTING
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (DIRECTIONAL BORE)
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
POWER PULL BOX
INTERCEPT EXISTING
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT03.DGN10:00:44 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 NB
I-75 SB
SOUTHBOUND MILE MARKER 338
WEIGH STATION 50662 (44 SPACES)
NORTHBOUND MILE MARKER 338
WEIGH STATION 50661 (45 SPACES)
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-03I-75 MARION
- SPARE
- POWER
- 2-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
FIBER OPTIC PULL BOX (TYP.)(EXISTING)
ELECTRICAL PULL BOX (TYP.)
FIBER PULL BOX (TYP.)
WEIGH STATION FIBER TRUNKLINE(EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
FIBER OPTIC SPLICE VAULT (TYP.)
(EXISTING)
ELECTRICAL PULL BOX (TYP.)(EXISTING)ELECTRICAL PULL BOX (TYP.)(EXISTING)
MVDS DETECTION ZONEMVDS DETECTION ZONE
MVDS DETECTION ZONEMVDS DETECTION ZONE
MVDS DETECTION ZONEMVDS DETECTION ZONEMVDS DETECTION ZONEMVDS DETECTION ZONE
PARCEL DERIVED R/WPARCEL DERIVED R/W
PARCEL DERIVED R/W
- MVDS
- CCTV
(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 2-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
ITS POWER SERVICE DROP (TYP.)(EXISTING)
- SPARE
- 3-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 4-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
8 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
8 FO TERMINATORS
1 DOME CCTV CAMERA (IP HD CAMERA)
2 BUFFER TUBE FAN OUT KIT
1 ETHERNET SWITCH
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 FOC PATCH PANEL
1 DEVICE SERVER
1 MVDS
1 POLE (TYPE II)
8 FO TERMINATORS
1 DOME CCTV CAMERA (IP HD CAMERA)
2 BUFFER TUBE FAN OUT KIT
1 ETHERNET SWITCH
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 FOC PATCH PANEL
1 DEVICE SERVER
1 MVDS
1 POLE (TYPE II)
4 FO TERMINATORS
1 BUFFER TUBE FAN OUT KIT
1 FOC CONNECTOR PANEL
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 DOME CCTV CAMERA (IP HD CAMERA)
1 MVDS
1 POLE (TYPE II)
4 FO TERMINATORS
1 BUFFER TUBE FAN OUT KIT
1 FOC CONNECTOR PANEL
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 DOME CCTV CAMERA (IP HD CAMERA)
1 MVDS
1 POLE (TYPE II)
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 NB
I-75 SB
SOUTHBOUND MILE MARKER 338
WEIGH STATION 50662 (44 SPACES)
NORTHBOUND MILE MARKER 338
WEIGH STATION 50661 (45 SPACES)
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-03I-75 MARION
- SPARE
- POWER
- 2-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
FIBER OPTIC PULL BOX (TYP.)(EXISTING)
ELECTRICAL PULL BOX (TYP.)
FIBER PULL BOX (TYP.)
WEIGH STATION FIBER TRUNKLINE(EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
FIBER OPTIC SPLICE VAULT (TYP.)
(EXISTING)
ELECTRICAL PULL BOX (TYP.)(EXISTING)ELECTRICAL PULL BOX (TYP.)(EXISTING)
MVDS DETECTION ZONEMVDS DETECTION ZONE
MVDS DETECTION ZONEMVDS DETECTION ZONE
MVDS DETECTION ZONEMVDS DETECTION ZONEMVDS DETECTION ZONEMVDS DETECTION ZONE
PARCEL DERIVED R/WPARCEL DERIVED R/W
PARCEL DERIVED R/W
- MVDS
- CCTV
(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 2-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
ITS POWER SERVICE DROP (TYP.)(EXISTING)
- SPARE
- 3-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 4-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
8 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
8 FO TERMINATORS
1 DOME CCTV CAMERA (IP HD CAMERA)
2 BUFFER TUBE FAN OUT KIT
1 ETHERNET SWITCH
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 FOC PATCH PANEL
1 DEVICE SERVER
1 MVDS
1 POLE (TYPE II)
8 FO TERMINATORS
1 DOME CCTV CAMERA (IP HD CAMERA)
2 BUFFER TUBE FAN OUT KIT
1 ETHERNET SWITCH
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 FOC PATCH PANEL
1 DEVICE SERVER
1 MVDS
1 POLE (TYPE II)
4 FO TERMINATORS
1 BUFFER TUBE FAN OUT KIT
1 FOC CONNECTOR PANEL
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 DOME CCTV CAMERA (IP HD CAMERA)
1 MVDS
1 POLE (TYPE II)
4 FO TERMINATORS
1 BUFFER TUBE FAN OUT KIT
1 FOC CONNECTOR PANEL
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 DOME CCTV CAMERA (IP HD CAMERA)
1 MVDS
1 POLE (TYPE II)
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT03A.DGN10:00:54 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
NORTHBOUND MILE MARKER 333.97
TPAS SIGN 50661
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-03AI-75 SUMTER
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDSOUTH OF WEIGH STATION 50661 (MM 338)3-DIGIT EMBEDDED DMS AT NB MM 333.97TRUCK PARKING AVAILABILITY SIGN WITH
N
LOCATOR
INTERSTATE
75
NB MM 33850661
STATIONWEIGH
NB MM 333.97VMS 50661
FIBER SPLICE VAULT
INTERCEPT EXISTING
ELECTRICAL PULL BOX (TYP.)(EXISTING)
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
NORTHBOUND MILE MARKER 333.97
TPAS SIGN 50661
SUMTER COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-03AI-75 SUMTER
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDSOUTH OF WEIGH STATION 50661 (MM 338)3-DIGIT EMBEDDED DMS AT NB MM 333.97TRUCK PARKING AVAILABILITY SIGN WITH
N
LOCATOR
INTERSTATE
75
NB MM 33850661
STATIONWEIGH
NB MM 333.97VMS 50661
FIBER SPLICE VAULT
INTERCEPT EXISTING
ELECTRICAL PULL BOX (TYP.)(EXISTING)
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT03B.DGN10:01:03 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
BI-75 S
B
SOUTHBOUND MILE MARKER 344.59
TPAS SIGN 50662
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-03BI-75 MARION
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDNORTH OF WEIGH STATION 50662 (MM 338)3-DIGIT EMBEDDED DMS AT SB MM 344.59TRUCK PARKING AVAILABILITY SIGN WITH
N
LOCATOR
INTERSTATE
75
SB MM 33850662
STATIONWEIGH
SB MM 344.59VMS 50662
FIBER SPLICE VAULT
INTERCEPT EXISTING
ELECTRICAL PULL BOX (TYP.)(EXISTING)
FIBER OPTIC SPLICE BOX (TYP.)(EXISTING)
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
ITS POWER SERVICE DROP (TYP.)(EXISTING)
ITS FIBER DROP CONDUIT (EXISTING)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
FIBER OPTIC PULL BOX (TYP.)
ELECTRIC PULL BOX (TYP.)
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
BI-75 S
B
SOUTHBOUND MILE MARKER 344.59
TPAS SIGN 50662
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-03BI-75 MARION
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDNORTH OF WEIGH STATION 50662 (MM 338)3-DIGIT EMBEDDED DMS AT SB MM 344.59TRUCK PARKING AVAILABILITY SIGN WITH
N
LOCATOR
INTERSTATE
75
SB MM 33850662
STATIONWEIGH
SB MM 344.59VMS 50662
FIBER SPLICE VAULT
INTERCEPT EXISTING
ELECTRICAL PULL BOX (TYP.)(EXISTING)
FIBER OPTIC SPLICE BOX (TYP.)(EXISTING)
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
ITS POWER SERVICE DROP (TYP.)(EXISTING)
ITS FIBER DROP CONDUIT (EXISTING)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
FIBER OPTIC PULL BOX (TYP.)
ELECTRIC PULL BOX (TYP.)
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT04.DGN10:01:10 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
I-75 NB
I-75 SB
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
NORTHBOUND MILE MARKER 345
REST AREA 50181 (45 SPACES)
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-04I-75 MARION
FIBER SPLICE VAULTINTERCEPT EXISTING
PARCEL DERIVED R/W
POWER CONDUIT WITH CONDUCTORS(EXISTING)
FIBER OPTIC PULL BOX(EXISTING)
ELECTRICAL PULL BOX (TYP.)
(EXISTING)
BREAKER PANEL
SUPPLIED FROM THE BUILDING
120/240 VAC SINGLE PHASE POWER
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
ITS FIBER TRUNKLINE (EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
ENTERING INTO EXISTING CABINET
CABLE USING EXISTING CONDUIT
INSTALL NEW COMMUNICATION
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- SPARE
- 1-12 STRAND FOC
2-2" CONDUIT (DIRECTIONAL BORE)
SEE SHEET IT-05 FOR DETAILS
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
I-75 NB
I-75 SB
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
NORTHBOUND MILE MARKER 345
REST AREA 50181 (45 SPACES)
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-04I-75 MARION
FIBER SPLICE VAULTINTERCEPT EXISTING
PARCEL DERIVED R/W
POWER CONDUIT WITH CONDUCTORS(EXISTING)
FIBER OPTIC PULL BOX(EXISTING)
ELECTRICAL PULL BOX (TYP.)
(EXISTING)
BREAKER PANEL
SUPPLIED FROM THE BUILDING
120/240 VAC SINGLE PHASE POWER
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
ITS FIBER TRUNKLINE (EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
ENTERING INTO EXISTING CABINET
CABLE USING EXISTING CONDUIT
INSTALL NEW COMMUNICATION
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- SPARE
- 1-12 STRAND FOC
2-2" CONDUIT (DIRECTIONAL BORE)
SEE SHEET IT-05 FOR DETAILS
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT04A.DGN10:01:16 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
NORTHBOUND MILE MARKER 342.10
TPAS SIGN 50181
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-04AI-75 MARION
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDSOUTH OF REST AREA 50181 (MM 345)3-DIGIT EMBEDDED DMS AT NB MM 342.10TRUCK PARKING AVAILABILITY SIGN WITH
NB MM 34650181
REST AREA
N
LOCATOR
INTERSTATE
75
200
27
NB MM 342.10VMS 50181
FIBER SPLICE VAULT
INTERCEPT EXISTING
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
NORTHBOUND MILE MARKER 342.10
TPAS SIGN 50181
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-04AI-75 MARION
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDSOUTH OF REST AREA 50181 (MM 345)3-DIGIT EMBEDDED DMS AT NB MM 342.10TRUCK PARKING AVAILABILITY SIGN WITH
NB MM 34650181
REST AREA
N
LOCATOR
INTERSTATE
75
200
27
NB MM 342.10VMS 50181
FIBER SPLICE VAULT
INTERCEPT EXISTING
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT05.DGN10:01:23 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
I-75 NB
I-75 SB
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
SOUTHBOUND MILE MARKER 346
REST AREA 50182 (44 SPACES)
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-05I-75 MARION
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
PARCEL DERIVED R/W
BREAKER PANEL
SUPPLIED FROM THE BUILDING
120/240 VAC SINGLE PHASE POWER
ELECTRICAL PULL BOX (TYP.)
(EXISTING)FIBER SPLICE VAULT(EXISTING)
ITS POWER SERVICE DROP(EXISTING)
ITS FIBER DROP CONDUIT (EXISTING)
- MVDS (EXISTING) ITS DEVICES
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 1-12 STRAND FOC
2-2" CONDUIT (OPEN TRENCH)
- SPARE
- 1-12 STRAND FOC
2-2" CONDUIT (DIRECTIONAL BORE)
- CCTV
(ADDED) ITS DEVICESSEE SHEET IT-04 FOR DETAILS
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
I-75 NB
I-75 SB
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
SOUTHBOUND MILE MARKER 346
REST AREA 50182 (44 SPACES)
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-05I-75 MARION
TO THE ACCESS POINT
FROM THE GROUND SENSORS
FOR TRANSMISSION OF MESSAGES
1 TYPE II POLE (TYP.)
1 REPEATER (TYP.)
PARCEL DERIVED R/W
BREAKER PANEL
SUPPLIED FROM THE BUILDING
120/240 VAC SINGLE PHASE POWER
ELECTRICAL PULL BOX (TYP.)
(EXISTING)FIBER SPLICE VAULT(EXISTING)
ITS POWER SERVICE DROP(EXISTING)
ITS FIBER DROP CONDUIT (EXISTING)
- MVDS (EXISTING) ITS DEVICES
IN-GROUND SENSORS (TYP.)
WILL HAVE AN ARRAY OF
EACH TRUCK PARKING STALL
8 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- 1-12 STRAND FOC
2-2" CONDUIT (OPEN TRENCH)
- SPARE
- 1-12 STRAND FOC
2-2" CONDUIT (DIRECTIONAL BORE)
- CCTV
(ADDED) ITS DEVICESSEE SHEET IT-04 FOR DETAILS
4 FO TERMINATIONS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 ETHERNET SWITCH
1 MEDIA CONVERTER
1 POLE
1 TYPE 336S ITS FIELD CABINET NEMA 3R
1 REPEATER
1 ACCESS POINT
1 DOME CCTV CAMERA (IP HD CAMERA)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
- SPARE
- POWER
- 1-12 STRAND FOC
3-2" CONDUIT (DIRECTIONAL BORE)
2/16/2017tsheppard \\tmaw00\jobs\63045\CADD\TWO7\its\District 5\PLANIT05A.DGN10:01:30 AM
440222-1-52-01
ROAD NO. FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTIONNO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
PURPOSE ONLYFOR ILLUSTRATION
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
SOUTHBOUND MILE MARKER 349.06
TPAS SIGN 50182
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-05AI-75 MARION
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDNORTH OF REST AREA 50182 (MM 346)3-DIGIT EMBEDDED DMS AT SB MM 349.06TRUCK PARKING AVAILABILITY SIGN WITH
SB MM 34650182
REST AREA
N
LOCATOR
INTERSTATE
75
200
27
SB MM 349.06VMS 50182
ELECTRICAL PULL BOX (TYP.)(EXISTING)
FIBER OPTIC SPLICE BOX (TYP.)(EXISTING)
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
ITS FIBER DROP CONDUIT (EXISTING)
FIBER OPTIC PULL BOX (TYP.)(EXISTING)
SW 43rd
St
SW 40th Rd
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES
- FPID 428213-1-52-01
EXISTING ITS INFRASTRUCTURE REFERENCE
I-75 N
B
I-75 S
B
SOUTHBOUND MILE MARKER 349.06
TPAS SIGN 50182
MARION COUNTY, FDOT DISTRICT 5
TRUCK PARKING AVAILABILITY SYSTEM
IT-05AI-75 MARION
- COMMUNICATION FROM NEAREST ITS CABINET- POLE MOUNTED NEMA CABINET- POWER FROM NEAREST ITS CABINET- 3-DIGIT EMBEDDED DMSSIGN SPACING REQUIREMENTS)(ADJUST SIGN LOCATIONS PER MUTCDNORTH OF REST AREA 50182 (MM 346)3-DIGIT EMBEDDED DMS AT SB MM 349.06TRUCK PARKING AVAILABILITY SIGN WITH
SB MM 34650182
REST AREA
N
LOCATOR
INTERSTATE
75
200
27
SB MM 349.06VMS 50182
ELECTRICAL PULL BOX (TYP.)(EXISTING)
FIBER OPTIC SPLICE BOX (TYP.)(EXISTING)
ITS FIBER TRUNKLINE (EXISTING)
POWER CONDUIT WITH CONDUCTORS(EXISTING)
- SPARE
- 1-12 STRAND FOC
- POWER
3-2" CONDUIT (OPEN TRENCH)
R/W LINE
PARCEL DERIVED
R/W LINE
PARCEL DERIVED
POWER PULL BOX
INTERCEPT EXISTING
ITS FIBER DROP CONDUIT (EXISTING)
FIBER OPTIC PULL BOX (TYP.)(EXISTING)
SW 43rd
St
SW 40th Rd
4 FO TERMINATORS
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
1 MULTI POST STATIC SIGN WITH EMBEDDED DMS
4 FO TERMINATORS, IN EXISTING ITS CABINET
1 FOC CONNECTOR PANEL
1 BUFFER TUBE FAN OUT KIT
1 FOC PATCH PANEL
1 MEDIA CONVERTER
USING EXISTING CONDUIT ENTERING INTO CABINET
INSTALL NEW POWER AND COMMUNICATION CABLES