Transcript
Page 1: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

FELIX-based Vertical Slice TestH. Chen, K. Chen, J. Fried, S. Gao, B. Viren, S. Tang, J. Zhang

DUNE Far Detector DAQ WorkshopBrookhaven National Laboratory

July 20th, 2018

Page 2: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Outline❏ Current Test Setup❏ Vertical Slice Test Setup for DUNE❏ Development Plan

2Shaochun Tang (BNL)

Page 3: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Current Test Setup

❏ ProtoDUNE at CERN❏ Test setup at BNL❏ Test Setup at Nikhef

3Shaochun Tang (BNL)

Page 4: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

ProtoDUNE Test Setup at CERN

FEMBx20

WIBx5

FELIXx1

4

ProtoDUNE-SP 5 WIBs

FELIX FLX712

APAx1

❏ LArTPC → ionisation tracks are collected by the wires of the Anode Plane Assemblies (APAs).

❏ 20 Front End Mother Boards (FEMB) digitize signals recorded by wires at 2 MHz. Each has up to 128 channels.

❏ 5 Warm Interface Boards (WIB), each WIB controls up to four 128-ch FEMBs❏ Output via optical links to DAQ:

❏ 2x 9.6 Gb/s or 4x 5 Gb/s supported, depending on readout solution❏ Continuous time-stamped data frame streams

❏ Each APA (2,560 channels) is read out by 5x WIBs for a total payload of about 74 Gb/s.

ProtoDUNE Test Setup at CERN Block Diagram FEMB

Shaochun Tang (BNL)

Page 5: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Block Diagram of ProtoDUNE Data flow

5

❏ Each FEMB has four links to WIB at 1.28 Gbps

❏ Each WIB accept 16 links from four FEMBs

❏ Each WIB is read out by two 9.6 Gbps FELIX links. Each link covers two FEMBs

Shaochun Tang (BNL)

Page 6: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Test Setup at BNL

❏ 4 FEMBs + 1 WIB + 1 FELIX (2 links are used)❏ Calibration data and pedestal data are tested.

❏ Each WIB has 2 links @ 9.6 Gbps❏ 1 FELIX has 24 Links @ 9.6 Gbps

6

FEMBx4

WIBx1

FELIXx1

Block Diagram of Test Setup at BNL

Shaochun Tang (BNL)

Page 7: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Test Setup at BNL - Test Results

7

❏ Left two figures are pedestal data of two FEMBs;

❏ The upright figure is one channel calibration data;

❏ the down right one is the time stamp data.

❏ Two links are running at 9.6Gb/s to FELIX successfully with real data and calibration data without CRC error.

❏ The WIB is freely running for 2 weeks, Both links are stable. We have set up a stability test for the WIB firmware. Till now, the firmware is very stable.

❏ Detailed results: https://indico.cern.ch/event/741215/contributions/3063991/attachments/1680963/2700648/WIB-FELIXmeeting-070418v1.pdf

Pedestal FEMB 1 Calibration data Channel 10 of FEMB2

Pedestal FEMB 2 Time stamp

Shaochun Tang (BNL)

Page 8: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Test Setup at Nikhef

❏ 1 Mini-FELIX + 1 FELIX or Mini-FELIX (4 links are used)❏ Data emulator is used at the Mini-FELIX (VC709) side.❏ 1 FELIX (FLX-711) or another Mini-FELIX (VC709) is used to receive

data. 4 Links @ 9.6 Gbps.

8

Mini-FELIX (VC709) x1FELIX (FLX-711) x1

orMini-FELIX (VC709) x1

Block Diagram of Test Setup at Nikhef

Shaochun Tang (BNL)

Page 9: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Vertical Slice Test for DUNE

Step 1: FELIX FLX-712 → FELIX FLX-712

Step 2: FELIX FLX-712 → New FELIX + DPM

Step 3: New FELIX + DPM → New FELIX + DPM

Step 4: Replacing the FLX-712 in ProtoDUNE setup with New FELIX + DPM

9Shaochun Tang (BNL)

Page 10: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Vertical Slice Test for DUNE (Step 1)

❏ Using two FELIX FLX-712 to do the test❏ Simulation data is generated at one FELIX.❏ Another FELIX is used to receive data.

10

FELIX (FLX-712) x1 FELIX (FLX-712) x1

The first step of VST based on the FLX-712

Shaochun Tang (BNL)

Page 11: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Vertical Slice Test for DUNE (Step 2)

❏ Using one FELIX FLX-712 and one new FELIX with DPM to do the test.❏ Initial test setup for new FELIX+DPM debug.❏ Simulation data is generated at the FELIX FLX-712.❏ The new FELIX with DPM is used to receive data.

11

FELIX (FLX-712) x1 FELIX + DPM x1

The second step of VST based on the FLX-712 and Modified FELIX +DPM

Shaochun Tang (BNL)

Page 12: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Vertical Slice Test for DUNE (Step 3)

❏ Using two new FELIX with DPM to do the test.❏ Simulation data is generated at one FELIX+DPM.

❏ This may take advantage of storage available on DPM.❏ The new FELIX with DPM is used to receive data.

12

FELIX + DPM x1 FELIX + DPM x1

The third step of VST based on the Modified FELIX +DPM

Shaochun Tang (BNL)

Page 13: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Vertical Slice Test for DUNE (Step 4)

❏ After verifying the FELIX+DPM, then can replace the FELIX in the ProtoDUNE test setup at CERN to do more tests.

13

The step 4: replacing the FELIX with FELIX+DPM in the protoDUNE test setup at CERN

FEMBx20

WIBx5

FELIX + DPM x1

APAx1

Shaochun Tang (BNL)

Page 14: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Development Plan

❏ Hardware:❏ Modification is minimal,❏ 10% work.

❏ Firmware:❏ Need to design lots of firmware blocks. Details refer to Kai and Frans slides. ❏ 40%.

❏ Software:❏ Need lots of software development❏ 50%.

❏ Integration:❏ Test… Test … Test...❏ 200%.

14Shaochun Tang (BNL)

Page 15: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Summary

❏ Vertical slice test takes real effort to make it successful (useful).❏ Firmware/software development should start as early as possible to meet tight

schedule (and goals).❏ It would be too late to start FW/SW development after hardware becomes available.❏ FLX-712 is available today to facilitate the setup of lab test stand, get familiar with firmware and

software design.❏ One (management) shall start to plan how to organize the various FW/SW developments, and

integration test ❏ Identify resources who will have (obtain) experiment specific expertise❏ Team building along the VST development serves as the backbone for DUNE FD DAQ system

❏ ProtoDUNE is the most important test platform to validate system design concepts.❏ It would be the best to exercise the VST with real detector in cosmic run, provided the early steps of

VST are sufficiently developed15Shaochun Tang (BNL)

Page 16: Test FELIX-based Vertical Slice - Indico · 2018-07-20 · Vertical Slice Test for DUNE (Step 1) Using two FELIX FLX-712 to do the test Simulation data is generated at one FELIX

Thank you for your attention

16Shaochun Tang (BNL)