Job Name LocationPurchaser EngineerSubmitted to Reference Approval ConstructionUnit Designation Schedule #
SUBMITTAL AJ009NBNDCH/AA
www.SamsungHVAC.com888-699-6067
Page 1 of 2
Samsung FJM Series, Wind-Free™ Mini 4-Way Cassette
© 2019 Samsung HVAC SHA-FJM-03262019
Cooling (Btu/h) 8,900
Heating (Btu/h) 9,900
1 / 208-230 / 60
0.51
Turbo (1)
Type BLDC (1)
FLA / Output 0.17A / 24 W
Airflow CFM L/M/H 244 / 290 / 318
R410AElectronic Expansion Valve
(at outdoor unit)
Liquid (flare) Inches 1/4
Suction (flare) Inches 3/8
Drain Inches OD 1 1/4, ID 1
W X H X D Inches 22 5/8 X 10 X 22 5/8
Weight 25.40
Sound Level L / H dB(A) 24 / 33
Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.
Piping Connections
Unit Dimensions
Fan
Type
Motor
RefrigerantType
Control Method
Specifications
Performance Nominal Capacity
PowerVoltage (ø/V/Hz)
Nominal Running Current (A)
lbs.
• Electro-static, washable, pleated filters as standard (included withfascia panel)
• Built in condensate pump with maximum 29" lift from the bottom of the unit, check valve, and float switch that disables indoor unit during overflow detection.
• Knock-out for outside air capability (with booster fan connection)
• Fascia panel shall have LED indicator lights, IR receiver, and 4motorized louvers with independent control.
• High-voltage terminal block temperature sensor to disable unit in theevent overheating of power connection.
• The indoor unit shall be powered by the outdoor unit
ConstructionGalvanized steel frame with HIPS chassis and fascia panel certified toUL94 V0.
Heat ExchangerThe heat exchanger shall be mechanically bonded fin to copper tube
Indoor FanIndoor fan is a single turbo type
Three fan speed settings and auto setting
ControlsControl signal shall be a DDC type signal
Interconnect control wire between outdoor and indoor shall be 16AWGX 2 shielded
The system shall integrate with the Samsung Controls Solution.
CompatibilityWill only operate with Samsung outdoor unit model numbers:AJ020JCJ2CH/AA, AJ020MCS3CH/AA, AJ024JCJ3CH/AA,AJ024MCS4CH/AA, AJ030MCS4CH/AA, AJ036JCJ5CH/AA,
MIM-B14
MCR-SMD
AR-EH03U
MWR-WH00U
25' - ILS2506
50' - ILS5006
ETL (UL 1995)Safety Certifications
Line sets - insulated and flared, interconnect cables included
Accessories
External Contact Control
Motion Occupancy Sensor
Wireless Remote Controller
Standard Wired Controller
• Wind-Free™ function will close the supply air outlet louver while incooling mode to gently disperse cool air into the space withoutblowing directly onto occupants. The Wind-Free™ feature isoptional and can be enabled using central or local control options(MWR-WE13U, AR-EH03U only).
• The Wind-Free™ 4-way cassette can be configured for 2-stageoperation, cooling the space with the louver open (fixed or swing)until the room temperature nears set temperature. Once roomtemperature is near set temperature, Wind-Free™ operation will startautomatically, closing the louver and using the face of the fasciapanel to gently cool the space with still air*.
*The Wind-FreeTM unit delivers an air current that is under 0.15 m/s while in Wind Free mode. Air velocity that is below 0.15 m/s is considered “still air” as defined by ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers).
24 3/8 X 24 3/8 X 2 1/4
lbs.Weight 6
Fascia Panel1(purchased separately)
L X W X H(Inches) 24 3/8 X 24 3/8 X 2 3/16
PC4SUFMUN (Wind-Free™)PC4SUSMUN (Standard)
1PC4SUFMUN fascia panel must be installed to use the Wind-Free™ functions. MWR-WE13U wired controller or AR-EH03U wireless remote control must be used to enable Wind-Free™ functions.
The Wind-Free™ panel (PC4SUFMUN) has an integral humiditysensor that will open the louvers for standard cool mode when spaceconditions could potentially cause condensation formation on thepanel surface.
•
MWR-WE13UWired Controller W/Scheduling & Wind-Free™
PC4SUFMUN
PC4SUSMUN
Wind Free™ Fascia Panel
Standard Fascia Panel
59" or more
59" or more
59" or more
59" or more
www.SamsungHVAC.com
SUBMITTAL
Proper clearance must be maintained around unit for proper operation.
No. Name Description
1234567
Liquid Pipe ConnectionGas Pipe ConnectionDrain Pipe ConnectionConduit for Power & Communication WiringAir Inlet GrilleAir Outlet LouverFresh Air Intake
Ø 1/4" FlareØ 3/8" Flare
OD 1 1/4", ID 1"---
Ø 4"
Page 2 of 2 AJ009NBNDCH/AA Samsung FJM Series, Wind-Free™ Mini 4-Way Cassette
Ø4"
22 13/16 ~ 23 1/16" Ceiling Opening
19 13/16" Suspension Point
19 1
3/16
" Sus
pens
ion
Poin
t
22 1
3/16
~ 2
3 1/
16" C
eilin
g O
peni
ng
22 5/8" 22 5/8"
1 5/
8"9
1/4"
7 3/
16"
3 1/
8"
6 3/4"
3 1/8"
5 15/16"5 7/16"
M4 Screw
11 13/16" 5 7/16"
4 11
/16"
12 5
/16"
9 5/
8"
7/8" 7/8"
8 7/8"8 5/16"
2" 5 1/
2"
7 3/
8"
Max
imum
21
5/16
" fro
m d
rain
con
nect
ion
(Max
imum
29"
from
bot
tom
of u
nit)
8 1/
8"
6 1/2"
9 13/16"
10 9/16"
2 5/
8"
24 3/8"
15"
24 3
/8"
15"
7
1
3
24
6
5
PC4SUFMUN Panel(Wind-Free™)