Drawing Description Drawing No.
Drawing Register
Introduction Series 000 FCS 001 - 004StoArmat Render System - Introduction FCS 005StoArmat Render System - Fibre Cement Sheet Information FCS 006StoArmat Render System - Sheet Layout FCS 007StoArmat Render System - Sheet and System Layout FCS 008
Sheet Layout Series 100StoArmat Render System StoArmat Plaster System - Isometric FCS 100
Foundation Series 200StoArmat Render System Foundation Slab-on-ground FCS 200StoArmat Render System Rebated Foundation Slab-on-ground - Rendered Finish FCS 201StoArmat Render System Conc.Foundation/Timber Floor FCS 202StoArmat Render System Conc.Block Foundation Edge Detail FCS 203StoArmat Render System Solid Conc.Foundation Edge Detail FCS 204StoArmat Render System Ribraft Floor System / Edge Detail FCS 205StoArmat Render System Maxraft Floor System / Edge Detail FCS 206
Walls Series 300StoArmat Render System Vertical Sheet Join FCS 300StoArmat Render System Horizontal Sheet Join FCS 301StoArmat Render System External Corner FCS 302StoArmat Render System Internal Corner FCS 303StoArmat Render System Vertical Control Joint FCS 304StoArmat Render System Horizontal Junction - Non Draining - Opt 1 FCS 305StoArmat Render System Horizontal Junction - Non Draining - Opt 2 FCS 306StoArmat Render System Horizontal Junction - Draining FCS 307
Wall Penetrations & Fittings Series 350StoArmat Render System Pipe Penetration (up to 100mm)Detail FCS 350StoArmat Render System Light Fitting/Fixing Detail FCS 351StoArmat Render System Tap Fitting/Fixing Detail FCS 352StoArmat Render System Handrail Bracket/Fixing Detail FCS 353StoArmat Render System Meterbox FCS 354StoArmat Render System Downpipe Saddle Fixing & Wiring Details FCS 355StoArmat Render System Fan Vent Detail FCS 356
THESE DETAILS ARE ISSUED AS A GUIDE USING STANDARD BUILDING PRACTICES BASED ON THE NZBC.VARIOUS BUILDING COMPONENTS ARE DETAILED AND IT IS THE RESPONSIBILITY OF EACH TRADE INVOLVED TOENSURE THAT THEIR PARTICULAR ELEMENTS ARE INSTALLED CORRECTLY. NOTE: REFER TO INDIVIDUALMANUFACTURES FOR CURRENT DETAILS AND SPECIFICATIONS - SEE www.sto.co.nz FOR CURRENT DETAILS.RBW DETAILS MUST BE ISSUED BY A; REGISTERED ARCHITECT, LICENSED DESIGNER OR CHARTERED ENGINEER
STO DRAWING REGISTER
PAGE 1 OF 4
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/ MONOTEK
STOARMAT RENDER SYSTEM
DRAWING REGISTER
FCS 001
2017
Drawing Description Drawing No.
Joinery Series 400StoArmat Render System Alu.Joinery - Head Detail FCS 400StoArmat Render System Alu.Joinery - Sill Detail FCS 401StoArmat Render System Alu.Joinery - Jamb Detail FCS 402StoArmat Render System Int.Cnr.Alu.Window/Door Joinery FCS 403StoArmat Render System Entry Door - Head Detail FCS 404StoArmat Render System Entry Door - Threshold Detail FCS 405StoArmat Render System Entry Door - Jamb Detail FCS 406StoArmat Render System Sliding Door - Head Detail FCS 407StoArmat Render System Sliding Door - Threshold Detail/Concrete Floor FCS 408StoArmat Render System Sliding Door - Threshold Detail/Timber Floor FCS 409StoArmat Render System Sliding Door - Jamb Detail FCS 410StoArmat Render System Bifold Door - Head Detail FCS 411StoArmat Render System Bifold Door - Threshold Detail/Concrete Floor FCS 412StoArmat Render System Bifold Door - Threshold Detail/Timber Floor FCS 413StoArmat Render System Bifold Door - Jamb Detail FCS 414StoArmat Render System Level Entry - Threshold Detail FCS 415StoArmat Render System Garage Door - Timber Head Detail FCS 416StoArmat Render System Garage Door - Timber Jamb Detail FCS 417StoArmat Render System Garage Door - Plaster Head Detail FCS 418StoArmat Render System Garage Door - Plaster Jamb Detail FCS 419
Parapets, Balustrades, Decks Series 500StoArmat Render System Parapet/Metal Flashing Detail FCS 500StoArmat Render System Rendered Parapet/Balustrade Detail FCS 501StoArmat Render System Parapet and/or Encl.Balustrade Wall Junction - Plan View FCS 502StoArmat Render System Flexible Flashing Install - Isometric FCS 503StoArmat Render System Metal Saddle Flashing & Cap Install - Isometric FCS 504StoArmat Render System StoFlexyl Meshed Saddle Flashing Install - Isometric FCS 505StoArmat Render System StoFlexyl Meshed Waterproofing Cap Install - Isometric FCS 506StoArmat Render System Balustrade/Encl.Deck Detail FCS 507StoArmat Render System Enclosed Deck Cross Section FCS 508StoArmat Render System Cantilevered Slatted Deck FCS 509StoArmat Render System Non Cantilevered Slatted Deck FCS 510StoArmat Render System Independent Slatted Deck FCS 511StoArmat Render System Timber Beam / Pergola Detail FCS 512StoArmat Render System RWH/Scupper Opening FCS 513
Soffit Series 600StoArmat Render System Flat Soffit/Wall Junction FCS 600 StoArmat Render System Raking Soffit/Wall Junction FCS 601StoArmat Render System Face Fixed Fascia FCS 602StoArmat Render System Raking Soffit Reversed FCS 603 StoArmat Render System Raking Soffit - Sto uPVC Control Joint FCS 604 StoArmat Render System Soffit to Cladding Detail FCS 605StoArmat Render System Gutter/Wall Junction FCS 606 StoArmat Render System Soffit at Window/Door Head FCS 607
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE USING STANDARD BUILDING PRACTICES BASED ON THE NZBC.VARIOUS BUILDING COMPONENTS ARE DETAILED AND IT IS THE RESPONSIBILITY OF EACH TRADE INVOLVED TOENSURE THAT THEIR PARTICULAR ELEMENTS ARE INSTALLED CORRECTLY. NOTE: REFER TO INDIVIDUALMANUFACTURES FOR CURRENT DETAILS AND SPECIFICATIONS - SEE www.sto.co.nz FOR CURRENT DETAILS.RBW DETAILS MUST BE ISSUED BY A; REGISTERED ARCHITECT, LICENSED DESIGNER OR CHARTERED ENGINEER
PAGE 2 OF 4
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
DRAWING REGISTER
FCS 002
2015
Drawing Description Drawing No.
Roof Series 700StoArmat Render System Apron (Transverse) Flashing FCS 700StoArmat Render System Parallel Apron (Parallel) Flashing FCS 701StoArmat Render System Inter-storey Transverse (Apron) Roof/Stopend FCS 702 StoArmat Render System Inter-storey Flat (Membrane) Roof/Stopend Flashing FCS 703StoArmat Render System Inter-storey Roof Stopend Flashing - PlanView FCS 704StoArmat Render System Roof Penetration Gutter (Masonry Tile) Detail FCS 705StoArmat Render System Roof Parallel Hidden Gutter FCS 706StoArmat Render System Face Fixed Fascia/Barge FCS 707StoArmat Render System Face Fixed Fascia/Membrane Roof FCS 708StoArmat Render System Roof/Wall Ridge FCS 709StoArmat Render System Framed Chimney FCS 710
Dissimilar Material
Weatherboard Series 800StoArmat Render System Ext.Corner Weatherboard/FC Sheet - Opt 1 FCS 800StoArmat Render System Ext.Corner Weatherboard/FC Sheet - Opt 2 FCS 801StoArmat Render System Ext.Corner Weatherboard/FC Sheet - Direct Fix FCS 802StoArmat Render System Int.Corner Weatherboard/FC Sheet - Opt 1 FCS 803StoArmat Render System Int.Corner Weatherboard/FC Sheet - Opt 2 FCS 804StoArmat Render System Int.Corner Weatherboard/FC Sheet - Direct Fix FCS 805StoArmat Render System Vertical Joint Flashing Weatherboard/FC Sheet FCS 806StoArmat Render System Horizontal Junction Weatherboard/FC Sheet FCS 807StoArmat Render System Gable End Weatherboard/FC Sheet FCS 808
Brick Series 810StoArmat Render System External Corner Brick Veneer/FC Sheet FCS 810StoArmat Render System Internal Corner Brick Veneer/FC Sheet - Opt 1 FCS 811StoArmat Render System Internal Corner Brick Veneer/FC Sheet - Opt 2 FCS 812
Fibre Cement Sheet Series 820 series not issued
Concrete Block Series 830StoArmat Render System External Corner Concrete Block/FC Sheet FCS 830StoArmat Render System Internal Corner Concrete Block/FC Sheet FCS 831StoArmat Render System Vertical Joint Concrete Block/FC Sheet FCS 832StoArmat Render System Horizontal Junction Concrete Block/FC Sheet FCS 833
Manufactured Stone - Schist & Natural Stone Series 840StoArmat Render System Ext.Cnr Manuf. Stone/FC Sheet FCS 840StoArmat Render System Boxed Ext.Cnr Stone Veneer/FC Sheet FCS 841StoArmat Render System Int.Cnr Manuf. Stone/FC Sheet FCS 842StoArmat Render System Vertical Junction Manuf. Stone/FC Sheet FCS 843StoArmat Render System Ext.Cnr Schist or Stone Veneer/FC Sheet FCS 844StoArmat Render System Int.Cnr Schist or Stone Veneer/FC Sheet FCS 845StoArmat Render System Vertical Junction Schist or Stone Veneer/FC Sheet FCS 846StoArmat Render System Horiz.Junction Schist or Stone Veneer/FC Sheet FCS 847
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE USING STANDARD BUILDING PRACTICES BASED ON THE NZBC.VARIOUS BUILDING COMPONENTS ARE DETAILED AND IT IS THE RESPONSIBILITY OF EACH TRADE INVOLVED TOENSURE THAT THEIR PARTICULAR ELEMENTS ARE INSTALLED CORRECTLY. NOTE: REFER TO INDIVIDUALMANUFACTURES FOR CURRENT DETAILS AND SPECIFICATIONS - SEE www.sto.co.nz FOR CURRENT DETAILS.RBW DETAILS MUST BE ISSUED BY A; REGISTERED ARCHITECT, LICENSED DESIGNER OR CHARTERED ENGINEER
PAGE 3 OF 4
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
DRAWING REGISTER
FCS 003
2017
Drawing Description Drawing No.
Continuation Dissimilar Material
Profile Metal Series 850 series not issued
StoTherm Panel EIFS Series 860 series not issued
DISSIMILAR JOINERY Series 870
TIMBER JOINERYStoArmat Render System Timber Window Joinery - Head Detail FCS 870StoArmat Render System Timber Window Joinery - Sill Detail FCS 871StoArmat Render System Timber Window Joinery - Jamb Detail FCS 872StoArmat Render System Timber Joinery - Timber Floor/Threshold Detail FCS 873StoArmat Render System Timber Joinery - Concrete Floor/Threshold Detail FCS 874
NK PVCu JOINERY series not issued
FLASHMAN JOINERY FLASHING SYSTEMStoArmat Render System Flashman Head Flashing FCS 878StoArmat Render System Flashman Sill Flashing FCS 879StoArmat Render System Flashman Jamb Flashing FCS 880HOMERIT PVC JOINERYStoArmat Render System Homerit PVC Joinery - Head Detail FCS 881StoArmat Render System Homerit PVC Joinery - Sill Detail FCS 882StoArmat Render System Homerit PVC Joinery - Jamb Detail FCS 883
MOULDINGS & SHAPESRefer to - www.accumen.co.nzLightweight exterior decorative moldings and shapes, including columns, architraves,cornices, window sills, fence caps, quoins that can be finished in Stolit K or MP spongecoloured finishing render.Note: Decorative mouldings require min. 10° MFCSope to top surface and a drip edge.
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE USING STANDARD BUILDING PRACTICES BASED ON THE NZBC.VARIOUS BUILDING COMPONENTS ARE DETAILED AND IT IS THE RESPONSIBILITY OF EACH TRADE INVOLVED TOENSURE THAT THEIR PARTICULAR ELEMENTS ARE INSTALLED CORRECTLY. NOTE: REFER TO INDIVIDUALMANUFACTURES FOR CURRENT DETAILS AND SPECIFICATIONS - SEE www.sto.co.nz FOR CURRENT DETAILS.RBW DETAILS MUST BE ISSUED BY A; REGISTERED ARCHITECT, LICENSED DESIGNER OR CHARTERED ENGINEER
PAGE 4 OF 4
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
DRAWING REGISTER
FCS 004
2017
SS404 STOARMAT RENDER SYSTEMBRANZ CERTIFICATE No.488
1. STOARMAT JOINTING ON SHEETS JOINTS2. STOARMAT MESHED REINFORCEMENT RENDER COMPLETELY OVER CLADDING3. STOKIT K or MP COLORED FINISHING RENDER IN 25Kg PAIL. EUROPEAN FIBRE REINFORCED
NON-CEMENT COLORED FINISHING RENDER, AVAILABLE IN 1.0/1.5/2.0 & 3.0mm SIZED TEXTUREAND MP or MP NATURAL SPONGE FINISHING RENDER
4. STOCOLOR : MAXICRYL MATT FACADE PAINT 15lt PAIL: LASTIC SATIN FACADE PAINT 15lt PAIL: LOTUSAN MINERAL RESIN PAINT 15lt PAIL
STOARMAT RENDER SYSTEMBRANZ APPRAISAL CERTIFICATE No.488 & 499 INCORPORATING:
JAMES HARDIE 7.5 or 9mm - MONOTEK FIBRE CEMENT SHEET
STOARMAT FULLY MESHED RENDER SYSTEM No. 488
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTRODUCTION
FCS 005
2017
SCALE NTS
ALL EDGES MUST BESUPPORTED WITH H3.1 CAVITYBATTENS ON TIMBER FRAMING.
ALL SHEETS FIXED VERTICALLY
CAVITY BATTEN LAYOUT ANDFIXINGS AS PER
MANUFACTURERS DETAILS ANDWIND ZONES
FIXINGS MIN.12mm FROM SHEETEDGES 1-2mm GAP IN SHEETS
BACK PRIME ANY AREASSUBJECT TO MOISTURE 12
00m
m x
180
0, 2
400,
270
0, 3
000
7.5 & 9mm SHEET THICKNESSES AVAILABLE
1200mm
2400
mm
7.5or 9mm
RE
BA
TED
ED
GE
RE
BA
TED
ED
GE
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FIBRE CEMENT SHEET INFORMATION
FCS 006
2017
SCALE 1:50
STOARMAT RENDER SYSTEM
1. KEEP SHEETS DRY BEFORE USING.2. READ SPECIFICATIONS AND CHECK DRAWINGS, DETAILS, FRAMING, UNDERLAY, FLASHING TAPES, AND BLOCKING IS SATISFACTORY3. INSTALL STO PVC TRAY AND JOINERY FLASHING AS PER STO DETAILS (BUILDER TO SUPPLY ALUMINUM HEAD FLASHING WITH STOPENDS)4. CHECK LAYOUT AND INSTALL SHEETS VERTICALLY STARTING FROM BOTTOM PLATE5. STAGGER VERTICAL SHEET JOINTS TO AVOID CONTINUOUS JOINS6. SECURE SHEETS WITH FIXINGS AS PER MANUFACTURERS DETAILS7. MEASURE DISTANCES ACCURATELY TO AVOID NARROW IN FILLS OR GAPS
SAFE WORKING PRACTICE
1. HAVE SUFFICIENT PEOPLE TO LIFT SHEETS ON SITE2. WEAR PROTECTIVE CLOTHING, EYE AND EAR PROTECTION AND DUST MASK OR RESPIRATOR WHEN CUTTING OR SANDING3. USE A CIRCULAR SAW FITTED WITH A DIAMOND BLADE OR F/C SCRIBER AND HEPA VACUUM WHEN CUTTING4. CONTAIN CUTTING AREA TO MINIMIZE DUST - HEPA VACUUM UP RESIDUE5. PROVIDE SUITABLE ACCESS PLATFORMS, EQUIPMENT AND TOOLS TO CARRY OUT THE WORK6. COMPLY WITH HEALTH AND SAFETY REGULATIONS AND MAINTAIN FIRST AID EQUIPMENT AS PER THE LEGISLATION
HORIZONTAL CONTROL JOINTS AT INTER-STOREY JUNCTIONSOR AT 5400mm MAX. ON CONTINUOUS STUDS
VERTICAL CONTROL JOINTS - 5400mm MAX.CTRS OR ATDISSIMILAR MATERIAL
200
MIN.200mmOVERLAP
VERTICALCONTROL JOINTOR 200mmOVERLAP
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SHEET LAYOUT
FCS 007
2017
N.T.S
SHEET JOINT 200mm MIN. FROMANY PARALLEL OPENINGS
1. SHEET JOINTS MUST NOT COINSIDE WITH JOINERY JAMB EDGES UNLESS ACONTROL JOINT IS TO BE FORMED
2. ALL SHEET EDGES SHALL LINE THROUGH AND BE SUPPORTED BY A FRAMINGMEMBER
3. LOCATE INTER-STOREY JOINTS AS PER BOARD MANUFACTURERSSPECIFICATIONS
4. STAGGER VERTICAL SHEET JOINTS AT INTER-STOREY JUNCTION5. HORIZONTAL CONTROL JOINTS AT INTER-STOREY JUNCTIONS
- 8mm VERTICAL CONTROL JOINTS AT 5.400M CTRS.MAX- INTER-STOREY DRAINED JOINTS EVERY THIRD FLOOR
VERTICAL CONTROLJOINT REQUIRED AT5.400M CTRS
INTER-STOREY CONTROLJOINT or FLASHING
STO PRE MESHEDCORNER ANGLE
STOARMAT MESHED JOINTING
STO GLASS MESH FOR STOARMATRENDER SYSTEM
SHEETS (sized to avoid infills)
H GRADE EPS SHEETS NORMALLY - 2700 x 1200mm
NOTE: USE FULL SHEETS WHERE POSSIBLEALL SHEET EDGES MUST BE SUPPORTED BY A FRAMING MEMBERALL SHEETS CUTS SHALL BE MADE CAREFULLY TO ACHIEVE A TIGHT BUTT FIT.
ANY GAPS IN THE EPS SHEET MUST BE FILLED WITH STO FOAM ON HORIZONTAL JOINTS CARE MUST BE TAKEN TO AVOID FOAM FILLING THE CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SHEET and SYSTEM LAYOUT
FCS 008
2017
SCALE 1:20
TIMBER FRAMINGTO NZS 3604
H3.1 TIMBER CAVITY BATTENS@ 300mm MIN.CTRS ON600mm FRAMING AS PERSHEET MANUFACTURERSDETAILS
STOARMAT uPVC CLIP ON FOOTTRAY. SHEET TO OVERHANGBOTTOM PLATE BY 50mm
WALL UNDERLAY MEETINGREQUIREMENTS E2/AS1
STOARMAT CLASSIC RENDER
CONCRETE FOUNDATION AS PER NZS3604 ORSPECIFIC ENGINEERING REQUIREMENTS
STOARMAT MESHED JOINT
STOLIT K & MP RANGECOLORED FINISHING RENDER
STO PUTZGRUND PRIMER
SELECTED REBATED EDGEFC SHEET
STO EUROPEAN MESH
1. FOR FIXING CENTERS REFER TO SHEETMANUFACTURERS SPECIFICATION
2. TIMBER FRAME MOISTURE CONTENTMUST NOT EXCEED 24% AT CLADDINGSTAGE
3. STOARMAT uPVC FLASHINGS AVALIABLEFOR BOTTOM TRAY, JOINERY & FINISHINGEDGES
VENTED VERMIN TRAY (byothers)
STOCOLOR MAXICRYLFACADE PAINT
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
STOARMAT RENDER SYSTEM - ISOMETRIC
FCS 100
2017
SCALE 1:5
OVERHANG RECOMMENDEDTO AVOID VARIANCES INFOUNDATION
TIMBER FRAMINGTO NZS 3604
DPC
INTERIOR LINING
50m
mC
lad.
AS PER NZS 3604:2011
DPM
6mm
CONCRETE SLAB/REINFORCINGAS PER NZS 3604 OR ENGINEERSPECIFIC DESIGN - NOT SHOWN
FOR CLARITY
20mm DRAINED & VENTEDCAVITY
7.5/9.0mm REBATED FIBRECEMENT SHEET
STO ARMAT RENDER SYSTEM
225m
m M
IN.
TO U
NP
AV
ED
GR
OU
ND
LE
VE
L
150m
m M
IN.
TO P
AV
ED
GL
uPVC VENT STRIP. MITRECORNERS & KEEP CLEAR OFDEBRIS
BATTENS AS PER SHEETMANUF. DETAILS
WALL UNDERLAY
STOARMAT CLIP ON FOOTTRAY
INSULATION AS PERNZBC - Clause H1
100m
m M
IN.
Sto
Ren
der
50m
mFl
exyl
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FOUNDATION SLAB-ON-GROUND
FCS 200
2017
TIMBER FRAMINGTO NZS 3604
DPC
STO RENDER SYSTEMTO FOUNDATION
SCALE 1:5
INTERNAL LINING
WALL UNDERLAY
20mm DRAINED CAVITY
STOARMAT RENDER SYSTEM
7.5/9.0mm REBATEDSHEET
BATTENS AS PER SHEETMANUF.DETAILS
50m
mC
lad.
DPM
AS PER NZS 3604
5
225m
m M
IN.
TO U
NP
AV
ED
GR
OU
ND
LE
VE
L
150m
m M
IN.
TO P
AV
ED
GL
CONCRETE SLAB/REINFORCINGAS PER NZS 3604 OR ENGINEERSPECIFIC DESIGN - NOT SHOWN
FOR CLARITY
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRISSTOARMAT CLIP ON FOOTTRAY
INSULATION AS PERNZBC - Clause H1
STOFLEXYL WATERPROOFINGTO REBATE, CONTINUE TO50mm PAST STO RENDERTERMINATION POINT
100m
m M
IN.
Sto
Ren
der
50m
mFl
exyl
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
REBATED SLAB-ON-GROUND -RENDERED FINISH
FCS 201
2017
SCALE 1:5
TIMBER FRAMINGTO NZS 3604
DPC
INTERIOR LINING
50
6mm OVERHANG RECOMMENDED TOAVOID VARIANCES IN FOUNDATION
6
15
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRIS
STOARMAT CLIP ON FOOTTRAY
CAVITY BATTENS AS PER MANUF.DETAILS
STOARMAT RENDER SYSTEM
7.5/9mm FIBRE CEMENT REBATEDSHEET AS PER MANUF. DETAILS
20mm DRAINED & VENTED CAVITYWALL UNDERLAY
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENTGROUND - REFER NZS3604:2011
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
CONCRETE FOUNDATION/TIMBER FLOOR
FCS 202
2017
225m
m u
npav
ed G
L
SCALE 1:5
CONCRETE FOOTING ASPER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
CONCRETE SLAB/REINFORCINGAS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
DPC
NOTE:SHELL OF BLOCK CAN SUPPORTBOTTOM PLATE WHEN SLAB ISTIED TO FOUNDATION
50m
m c
ladd
ing
150m
m to
pav
ing
GLINSULATION AS PERNZBC - Clause H1
DPM
WALL UNDERLAY
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET
STOARMAT RENDER SYSTEM
BATTENS AS PER SHEETMANUF. DETAILS
uPVC VENT STRIP. MITRECORNERS & KEEP CLEAROF DEBRIS
STOARMAT CLIP ON FOOT TRAY.
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
CONC.BLOCK FOUNDATION EDGE DETAIL
FCS 203
2017
SCALE 1:5
50m
m c
ladd
ing
150m
m to
pav
ing
225m
m u
npav
ed G
L
INSULATION AS PERNZBC - Clause H1
DPM
DPC10mm INSULATIONIF SPECIFIED
GL
CONCRETE SLAB/REINFORCINGAS PER NZS 3604 OR SPECIFIC
ENGINEER DESIGN (SED)
Var
ies
refe
r to
NZS
3604
or S
ED
WALL UNDERLAY
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET
STOARMAT RENDERSYSTEM
BATTENS AS PER SHEETMANUF. DETAILS
uPVC VENT STRIP. MITRECORNERS & KEEP CLEAROF DEBRIS
STOARMAT CLIP ON FOOT TRAY.
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SOLID CONC.FOUNDATION EDGE DETAIL
FCS 204
2017
50m
m c
ladd
ing
150m
m to
pav
ing
225m
m u
npav
ed G
L
DPC
GL
WALL UNDERLAY
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET
STOARMAT RENDERSYSTEM
BATTENS AS PER SHEETMANUF. DETAILS
uPVC VENT STRIP. MITRECORNERS & KEEP CLEAROF DEBRIS
STOARMAT CLIP ON FOOT TRAY.
RIBRAFT POLYSTYRENE PODINSTALLATION IN ACCORDANCETO FIRTH RIBRAFTCONSTRUCTION DETAILS
8522
0
CONCRETE SLAB/REINFORCINGAS PER NZS 3604, SPECIFIC
DESIGN OR ENGINEER (SED)Reinforcing not shown for clarity
300
SCALE 1:5
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
RIBRAFT FLOOR SYSTEM / EDGE DETAIL
FCS 205
2017
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEETSTOARMAT RENDER SYSTEM
BATTENS AS PER SHEET MANUF.DETAILSuPVC VENT STRIP. MITRE CORNERS &KEEP CLEAR OF DEBRIS
STOARMAT CLIP ON FOOT TRAY.
SCALE 1:10
1. CONCRETE SLAB/REINFORCING AS PER NZS 3604, SPECIFIC DESIGNOR ENGINEER (SED)
Reinforcing not shown for clarity2. WHERE INSULATION OS BELOW GROUND, APPLY TWO (2) COATS OF
STOFLEXYL TO MAXRAFT INSULATION BEFORE COMMENCING3. 150mm MIN. CLEARANCE FROM SLAB LEVEL TO EXTERIOR PAVING,
225mm MIN. CLEARANCE FROM SLAB LEVEL TO UNPAVED GROUND TOE2/AS1
4. LAP AN EIFS FLASHING TAPE MIN. 75mm ONTO DPM AT FOUNDATIONAND RETURN MIN. 50mm UP ONTO MAXRAFT FOUNDATION WALL.
SOLID COMPACTION800mm MIN. PAST EDGEOF FOUNDATION
100
100
50
250
10450
STOMULTI SCREED MESHED BASECOATFINISHED IN 1.0mm FLOAT or STOLIT KFINISHING RENDER, PAINTED INSTOCOLOR MAXICRYL
WALL UNDERLAY
50
REFER NOTE 4 BELOW
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
MAXRAFT FLOOR SYSTEM / EDGE DETAIL
FCS 206
2017
SCALE 1:2
STOARMAT RENDERSYSTEM
20mm NOMINAL VERTICALCAVITY BATTENS
WALL UNDERLAY
1-2mm SHEET GAP12mm MIN12mm MIN
STOARMAT MESHED JOINT
INSTALL SHEETS WITH A1-2mm GAP AT SHEET JOINT.
FIX SHEETS WITH HARDIESFIXINGS AS PER
MANUFACTURERS LAYOUTWITH FIXINGS MINIMUM
12mm FROM SHEET EDGES
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
VERTICAL SHEET JOINT
FCS 300
2017
SCALE 1:2
STOARMAT RENDERSYSTEM
140mm VERTICAL TIMBERCAVITY PACKER AT 150mmMAXIMUM CENTRESBETWEEN TIMBER CAVITYBATTENS
WALL UNDERLAY
1-2m
m S
HE
ET
GA
P15
-20m
m15
-20m
m
STOARMAT MESHED JOINT
INSTALL SHEETS WITH A1-2mm GAP AT SHEET JOINT.FIX SHEETS WITH HARDIESFIXINGS AS PERMANUFACTURERS LAYOUTWITH FIXINGS 15-20mmFROM SHEET EDGES
140X45 NOG ON EDGE OFFRAMING
THIS METHOD IS USED TO INSTALL FULL HEIGHT SHEETS WHERE THEWALL HEIGHT IS TALLER THAN THE STANDARD SHEET HEIGHT. THISMETHOD MUST NOT BE USED AT FLOOR JOISTS OR GABLE ENDS AS ACONTROL JOINT.
7.5/9/0mm REBATED SHEET
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZONTAL SHEET JOINT
FCS 301
2017
SCALE 1:2
WALL UNDERLAY
STOARMAT RENDERSYSTEM
40x19mm H3.1 TIMBERCAVITY BATTENS
20mm DRAINED CAVITY
7.5/9.0mm REBATEDSHEET WITH RECESSEDEDGE AT CORNER
35m
m M
IN
40mm MIN
1-2mm GAP
STOARMAT MESHEDJOINT USING uPVCPREMESHED CORNERBEAD
MS SEALANT TO SHEETGAP
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
EXTERNAL CORNER
FCS 302
2017
SCALE: 1:2
WALL UNDERLAY CONTINOUSAROUND CORNERS
DOUBLE STUDREQUIRED
FOR CLADDING SHEETS -REFER MANUFACTURER FORSPECIFIC FIXING DETAILS
SELECTED SHEET FIXING,12mm FROM SHEET EDGE -AS PER MANUFACTURERSRECOMENDATIONS
uPVC 50x50mm CORNERFLASHING
8mm BETWEEN SHEETS,STOARMAT - FLUSH FINISH
STOARMAT RENDER SYSTEMDOUBLE MESHED IN CORNER
8mm GAP
12mm MIN
20mm NOMINAL VERTICALCAVITY BATTENS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTERNAL CORNER
FCS 303
2017
SCALE 1:2
NOTE: REMOVE CONTROL JOINT TAB CAREFULLY AS SOON AS ARMAT HASSET TO AVOID CRACKS IN THE SYSTEM.
VERTICAL CONTROL JOINTS AT 5.4M CTRS MAX.PREFERABLY ABOVE &BELOW JOINERY JAMB LINE.
INSTALL STO uPVC CONTROLJOINT WITH MS SEALANT INSTOARMAT MESH COAT
8
STOARMAT RENDER SYSTEM
20mm NOMINAL VERTICALCAVITY BATTENS
12mm MIN.12mm MIN.
50mm WIDE INSEALTAPE
WALL UNDERLAY
5.400M TO EXT.CNR OR NEXT CONTROL JOINT
7.5/9.0mm REBATEDSHEET
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
VERTICAL CONTROL JOINT
FCS 304
2017
SCALE 1:2
WALL UNDERLAY - ENSUREUNDERLAY RUNS CONTINUOUSOVER JOINT
7.5/9.0mm REBATED SHEETIN ACCORDANCE WITHSHEET MANUFACTURERSDETAILS
STOARMAT RENDER SYSTEM
NOMINAL 20x45mm H3.1TIMBER CAVITY BATTENS ASPER SHEET MANUF. DETAILS
HORIZ.uPVC CONTROL JOINTFLASHING (staple to batten)
DONOT SEAL BETWEENPROFILE AND SHEET
15
10m
m G
AP PREMESHED ARCHITECTURAL
PROFILE OVER INTER-STOREYJOINT - SUPPLIED & FIXED BYCONTRACTOR
7.5/9.0mm REBATED SHEETFIXED IN ACCORDANCE WITHSHEET MANUFACTURER
STOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZ.JUNCTION - NON DRAINING- OPT 1
FCS 305
2017
SCALE 1:2
WALL UNDERLAY - ENSUREUNDERLAY RUNS CONTINUOUSOVER JOINT
7.5/9.0mm REBATED SHEETAS PER SHEETMANUFACTURERS DETAILS
STOARMAT RENDER SYSTEM
HORIZONTAL CAVITY SPACERS
NOMINAL 20x45mm H3.1TIMBER CAVITY BATTENS ASPER SHEET MANF. DETAILS
10
10m
m G
AP
7.5/9.0mm REBATED SHEETIN ACCORDANCE WITHSHEET MANF. DETAILS
STOARMAT RENDERSYSTEM
STO uPVC 12mmINTER-STOREY JOINT
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZ.JUNCTION - NON DRAINING- OPT 2
FCS 306
2017
20mm DRAINED CAVITY
FLASHING TAPE OVER
ALLOW TO RENDER BEHINDTHEN SEAL WITH MS SEALANTOR STO SEAL TAPE
1. AS REQUIRED TO LIMITCONTINUOUS CAVITYCONSTRUCTION TO TWOSTOREYS, FLASHING BACK ANDFRONT COVER TO BE A MINIMUM35mm EXCLUDING DRIP EDGES
2. IN EXTRA HIGH WIND ZONESINCREASE FLASHING COVER TO60mm MIN.AND USE A RIGIDUNDERLAY
SCALE: 1:2
MIN
.CO
VE
R
MIN
.CO
VE
R
35m
m
35m
m
STOARMAT RENDER SYSTEM
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILS
20mm DRAINED CAVITY
FIX AS PER SHEET MANUF.DETAILSWALL UNDERLAY - ENSUREUNDERLAY RUNS CONTINUOUSOVER JOINT
WALL UNDERLAY - ENSUREUNDERLAY RUNS CONTINUOUSOVER JOINT
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRISSTO uPVC CLIPON FOOT TRAY
STOARMAT RENDER SYSTEM7.5/9.0mm REBATED SHEET
15° SLOPE TO INTER-STOREYFLASHING - REFER E2/AS1 FORFLASHING DURABILITY
15
15
MIN.GAP FORMOVEMENT
STO uPVC 6mm FINISHINGEDGE
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZONTAL JUNCTION - DRAINING
FCS 307
2017
100mm min.
SCALE 1:5
FLASHING TAPE
STAR CUT
CUT LINES
8/10mm SEALANT BEAD ON PEF RODBETWEEN PIPE AND PLASTER
PIPE OR OTHER PENETRATIONSLOPED DOWNWARDS
NOTE: INSTALL FLASHING TAPE WITH 100mm CLEARANCE AROUND PIPE ONTO WALLUNDERLAY AND WRAP 25mm ROUND PIPE.
WHERE MIN 75mm BLOCKING SUPPORTS THE WALL UNDERLAY AROUND THEPENETRATION THE FLASHING TAPE CAN BE OMITTED BUT A FACE FIXEDEXTERIOR FLANGE WITH SEALANT IS REQUIRED AS PER E2AS1 FIG.68
TIMBERFRAMING TO
NZS3604
WALL UNDERLAY
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILSSTOARMAT RENDERSYSTEM
CAVITY BATTENS
FLASHING TAPE
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
PIPE PENETRATION (up to 100mm) DETAIL
FCS-350
2017
CAVITY BATTENS
SCALE 1:2
WALL UNDERLAY
50 x 3mm EPDM WASHERGASKETS REQUIRED AROUNDFIXINGS AND PLATE TO PROVIDEWATERTIGHTNESSTIMBER PACKER SLOPED AT 5°50mm min CLEARANCE FROMCAVITY BATTENSTIMBER BLOCKING BETWEENSTUDS AS REQUIRED
ALL WIRING SHOULD BEENCLOSED IN CONDUIT
CABLES SLOPE OUT
7.5/9.0mm REBATED SHEET - FIXED INACCORDANCE WITH MANUF. DETAILSSTOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
LIGHT FITTING/FIXING DETAIL
FCS 351
2017
SCALE 1:2
TAP FITTING ON EPDMRUBBER WASHER
PROVIDE TIMBERBLOCKING AT TAP
FLASHING TAPE100mm ONTO UNDERLAY25mm ONTO TAP CONNECTION
CAVITY BATTENS7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHMANUF. DETAILSSTOARMAT RENDER SYSTEM
WALL UNDERLAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TAP FITTING/FIXING DETAIL
MCS 352
2017
SCALE 1:2
WALL UNDERLAY
7.5/9.0mm REBATED SHEET - FIXED INACCORDANCE WITH MANUF. DETAILSSTOARMAT RENDER SYSTEM
SELECTED HANDRAIL
TIMBER PACKER AT FIXINGSPOINTS - SLOPED AT 5DEGREES min. 50mmCLEARANCE FROM CAVITYBATTENS
NOTE: USE A FIXING PLATES ON HANDRAILS TO AVOID POINT LOADING
50 x 3 mm EPDM WASHER GASKETSREQUIRED AROUND FIXINGSBETWEEN PLATE AND RENDER TOPROVIDE WATERTIGHTNESS
TIMBER BLOCKINGBETWEEN STUDS ASREQUIRED
100mm MAX.NZBC D1 clause 1.5.2
20mm DRAINED CAVITY
INSTALL HANDRAIL PLATES OVER STORENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HANDRAIL BRACKET/FIXING DETAIL
FCS 353
2017
SCALE 1:2
METERBOX
WALL UNDERLAY RETURNEDINTO OPENING WITH FLASHINGTAPE 25mm ONTO METERBOX
88
INTERNAL LINING
TIMBER FRAMINGTO NZS3604
INTERNAL LINING
TIMBER FRAMINGTO NZS3604
MS SEALANT OVER PEF BACKERROD TO PERIMETER OF METERBOX
STOARMAT uPVC CLIP ONTRAY - remove drip edge
8mm AIRSEAL ONPEF ROD BYBUILDER
8mm AIRSEAL ONPEF ROD BYBUILDER
STOARMAT RENDER SYSTEM
METERBOX
CAVITY BATTEN WITH 50mm GAPFROM HORIZONTAL SLOPEDBATTEN AT BOTTOM JUNCTION
FLASHING TAPE OVER MIN.10° SLOPEDBATTEN ONTO WALL UNDERLAY
HORIZONTAL BATTEN SLOPED AT 10°INTO CAVITYSTOARMAT uPVC CLIP ONTRAY - remove drip edgeMS SEALANT OVER PEF BACKERROD TO PERIMETER OF METERBOX
STOARMAT RENDER SYSTEM
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHMANUF. DETAILS
WALL UNDERLAY
7.5/9.0mm MONOTEK SHEET
FLASHING TAPE SEALED TOMETERBOX AND WALL UNDERLAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
METERBOX - CROSS SECTION
FCS 354
2017
SCALE 1:2
uPVC OR OTHERDOWNPIPE -SIZE REFERNZBC E1 Table 5
SUITABLE BLOCKING ATA 5° SLOPE min 50mm
CLEARANCE FROMVERTICAL CAVITY
BATTENS
DOWNPIPE/CLIP -SADDLE @ 1.2MCTRS MAX.
MS SEALANT AROUND CONDUIT
CABLE/WIRING
PVC CONDUIT SLEEVE INSTALLEDAT 5 DEGREES DOWNWARDSLOPE TO MESH COAT.APPLICABLE TRADE TO ENSUREFINISHED INSTALLATION ISWATERTIGHT
1. DOWNPIPE/CLIP - SADDLE DETAIL
2. WIRING PENETRATION DETAILNOTE: ENSURE THE AMOUNT OF PENETRATIONS THROUGH THESYSTEM IS KEPT TO A MINIMUM. THE WEATHERSEALING OF ALL WIRING,ETC AS SHOWN, IS THE RESPONSIBILITY OF THE APPLICABLE TRADE
TIMBER FRAMINGTO NZS3604
20mm DRAINED & VENTEDCAVITY7.5/9.0mm REBATED SHEET - FIXED INACCORDANCE WITH SHEET MANUF. DETAILSSTO ARMAT RENDER SYSTEM
WALL UNDERLAY
20mm DRAINED & VENTEDCAVITY
STOARMAT RENDER SYSTEM
WALL UNDERLAY
7.5/9.0mm REBATED SHEET - FIXED INACCORDANCE WITH SHEET MANUF. DETAILS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
DOWNPIPE SADDLE FIXING & WIRING DETAILS
FCS 355
2017
SCALE 1:2
EXTRACTION PIPE SLOPEDOWNWARDS AT MINIMUM 5°
FAN
CO
VE
R
TIMBER BLOCKING ASREQUIRED
NOTE:LEAVE 40mm DRAINAGE GAP IN SEALANT AT BOTTOM OF FAN COVER.INSTALL FLASHING TAPE 100mm AROUND PIPE ONTO WALL UNDERLAY AND WRAP25mm ROUND PIPE.FOR FLEXIBLE PIPES, TAPE PIPE TO FAN COVER, APPLY STO JOINT SEAL, TAPEAROUND TAPE BEFORE PLACING IN HOLE. ALWAYS FINISH RENDER BEFOREINSTALLING FAN COVER
TIMBER FRAMING ASPER NZS 3604
TIMBER BLOCKING ASREQUIRED
FLEXIBLE FLASHINGTAPE
MS SEALANT ALL ROUND,LEAVE 40mm DRAINAGEGAP AT BOTTOM
MS SEALANT/PEF RODAT PIPE JUNCTION (STOSEAL TAPE ON FLEXIBLEPIPES)
FLEXIBLE FLASHINGTAPE
20mm NOMINAL CAVITY BATTENS - ASPER SHEET MANUFACTURERS DETAILS
STOARMAT RENDER SYSTEM
7.5/9.0mm REBATED SHEET - FIXEDAS PER SHEET MANUF. DETAILS
WALL UNDERLAY20mm NOMINAL CAVITY BATTENS -AS PER SHEET MANUF. DETAILS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FAN VENT DETAIL
FCS 356
2017
STOARMAT RENDER SYSTEMREBATED SHEET TO OVERHANG CAVITY CLOSER BY15mm min. FIT CLIP ON TRAY AND LEAVE 5mm min.CLEARANCE TO HEAD FLASHING1. PROPRIETARY ALUM. HEAD FLASHING TO COVER
WINDOW FACING BY 10mm SLOPED 15° WITH min.35mm UPSTAND TAPED TO WALL UNDERLAY.ALLOW HEAD FLASHING TO PASS JAMBS BY 20mmAND FIT STOP ENDS IN CAVITY. FLASHING TAPESYSTEM TO BE INSTALLED AROUND JOINERYOPENINGS AS PER E2/AS1 BY BUILDER.
2. IN EXTRA HIGH WIND ZONES INCREASE FLASHINGCOVER TO 60mm MIN. AND USE A RIGIDUNDERLAY
SCALE 1:2
TIMBER LINTEL ASPER NZS 3604
FLASHING TAPE ONTO WALLUNDERLAYVENTED CAVITY CLOSERmin. 15mm FROM TRAY
ALUMINIUM WINDOWHEAD FLASHING WITH 15°SLOPE AND 10mm COVERAT WINDOW HEAD
MIN. 5mm GAP REQUIRED
NOTE: SEALANT REQUIREDFOR VERY HIGH AND EXTRAHIGH WIND ZONESALUMINIUM WINDOWJOINERY
INTERIOR LINING
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX
WALL UNDERLAY
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILSSTOARMAT RENDER SYSTEM
20mm DRAINED CAVITY*
25m
m35
15
5mm
GAP
* THIS DIMENSION MUSTBE CHECKED WITH
JOINERY MANUFACTURER
STO uPVC CLIP-ON FOOTTRAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ALUMINIUM JOINERY - HEAD DETAIL
FCS 400
2017
SCALE 1:2
JOINERY SUPPORT BARREQUIRE FOROPENINGS OVER 600mm
1. PROVIDE 6mm MIN.FILLET BEAD OF MS SEALANT TO JAMBS & SILL2. BUILDER TO INSTALL FLASHING TAPE TO CORNERS & SILL OVER WALL UNDERLAY3. POSITION WINDOW OFF BOARD BY 2-3mm TO ALLOW FOR STOARMAT JAMB & SILL
FLASHINGS
WARNING: SOME BRANDS OF ALUMINIUM JOINERY HAVE DRAINAGE VENTS IN THE BOTTOM EDGE OF THE SILL FLANGE.ENSURE DRAINAGE VENTS REMAIN CLEAR.
PROPRIETARY ALUM.WINDOW JOINERY
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILS
VERTICAL CAVITYBATTENS
FRAME BLOCK
TIMBER FRAMINGTO NZS 3604
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX.
INTERIOR LINING
WALL UNDERLAY RETURNEDINTO OPENINGS & FLASHING
TAPE CONTINUOUS ALONGSILL MIN 100mm UP JAMBS &50mm ONTO FACE OF WALL
UNDERLAY
MS SEALANT
STOARMAT uPVC SILLFLASHING
REMOVE FLASHING TEARTAB & APPLY MS SEALANT
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ALUMINIUM JOINERY - SILL DETAIL
FCS 401
2017
SCALE 1:2
ALUMINIUMWINDOW JOINERY
FLASHING TAPE(100mm UP JAMBS)
H1.2 PACKER TOSUPPORT JOINERY
INTERNAL LINING
TIMBER FRAMINGTO NZS 3604
MS SEALANT TO JAMBS
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX.
LINE OF HEAD FLASHINGOVER WITH STOPEND
1. PROVIDE 6mm MIN.FILLET BEAD OF MS SEALANT TO STOARMAT JAMB & SILL FLASHING2. BUILDER TO INSTALL FLASHING TAPE TO OPENINGS OVER WALL UNDERLAY AS PER E2/AS13. POSITION WINDOW OFF BOARD BY 2-3mm TO ALLOW FOR STOARMAT JAMB & SILL FLASHING
STOARMAT RENDER SYSTEM
WALL UNDERLAY7.5/9.0mm REBATED SHEET - FIXED IN
ACCORDANCE WITH SHEET MANUF. DETAILSCAVITY BATTENS
STOARMAT uPVC JAMBFLASHING GLUE OR BED
FLASHING IN PLACE BEFORERENDERING
5 10mmMIN.COVER
LINE OF HEAD FLASHING20mm MIN.PAST JAMB
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ALUMINIUM JOINERY - JAMB DETAIL
FCS 402
2017
SCALE 1:2
ALUMINIUM WINDOW/DOORJOINERYMS SEALANT
WALL UNDERLAY
STO uPVC JAMB FLASHING GLUEOR BED FLASHING IN PLACEBEFORE RENDERING
AIRSEAL ON PEF ROD,GAP 7.5-8mm APRROX.
FLASHING TAPE (100mmUP JAMBS)
H1.2 PACKER TOSUPPORT JOINERY
LINE OF HEAD FLASHINGOVER WITH STOPEND
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILSSTOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INT.CNR ALU.WINDOW/DOOR JOINERY - JAMB DETAIL
FCS 403
2017
SCALE 1:5
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILS
WALL UNDERLAY
FLASHING TAPE OVER HEADFLASHING ONTO WALL UNDERLAYuPVC VENT STRIP
ALUMINIUM WINDOW HEAD FLASHINGTO EXTEND 20mm MIN.PAST JAMBSWITH 15° SLOPE AND 10mm COVER ATWINDOW HEAD
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FOR VERY HIGHAND EXTRA HIGH WIND ZONESALUMINIUM DOOR JOINERY
AIRSEAL ON PEFROD GAP 7.5-8mmAPPROX
5
STOARMAT RENDER SYSTEM
STO uPVC CLIP-ON FOOT TRAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ENTRY DOOR HEAD DETAIL
FCS 404
2017
SCALE 1:5
50
ALU.OPEN INDOOR JOINERY
LINE OF STOARMAT RENDERSYSTEM BEYOND - SHOWNDASHED
TURN UP FLASHING TAPE100mm MIN.AT TRIMMERSTUDS 10
0
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604:2011
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ENTRY DOOR THRESHOLD DETAIL
FCS 405
2017
SCALE 1:5
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX & PACKER
WALL UNDERLAY LAPPED &STAPLED ON INSIDE EDGE.FLASHING TAPE OVER AS PERE2/AS1 100mm UP JAMBS
DRESSED PINE PRIMED REVEALS& ARCHITRAVES
7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITH
SHEET MANUF. DETAILSSTOARMAT RENDER
SYSTEM
STO uPVC JAMB FLASHING
ALUMINIUM DOORJOINERYMS SEALANT
CAVITY BATTEN
WALL UNDERLAY
LINE OF HEAD FLASHING20mm MIN.PAST JAMBS -SHOWN DASHED
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ENTRY DOOR JAMB DETAIL
FCS 406
2017
SCALE 1:5
WALL UNDERLAY RETURNEDINTO OPENINGS & FLASHING
TAPE AT CORNERS
ALU.SLIDING DOORJOINERY
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX
FLASHING TAPE OVER HEADFLASHING ONTO WALL UNDERLAY
ALUMINUM HEAD FLASHING TO EXTEND20mm MIN.PAST JAMBS WITH 15° SLOPEAND 10mm COVER AT DOOR HEADSEALANT REQUIRED FOR VERY HIGHAND EXTRA HIGH WIND ZONES
5
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRISSTOARMAT CLIP ON FOOT TRAY
WALL UNDERLAY20mm DRAINED & VENTED CAVITY7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILSSTOARMAT RENDER SYSTEM
100mm LONG HORIZONTAL BATTENBEYOND
MIN.5mm GAP REQUIRED
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SLIDING DOOR HEAD DETAIL
FCS 407
2017
SCALE 1:5
ALU.SLIDINGDOOR JOINERY
LINE OF STOARMATRENDER SYSTEMBEYOND - SHOWNDASHED50
TURN-UP FLASHING TAPE 100mmMIN.AT TRIMMER STUDS
100
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604:2011
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SLIDING DOOR THRESHOLD - CONCRETE FLOOR
FCS 408
2017
SCALE 1:5
5020
6mm MIN.OVERHANG
ALU.SLIDING DOORJOINERY
20mm DRAINED & VENTEDCAVITY
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRISSTOARMAT CLIP ON FOOT TRAY
STOARMAT RENDER
MS SEALANTSTO uPVC SILL & JAMBFLASHING
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604:2011
100mm DRAPE TODOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -REFER NZBC - Clause H1
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SLIDING DOOR THRESHOLD - TIMBER FLOOR
FCS 409
2017
SCALE 1:5
ALU.SLIDING DOORJOINERY
WALL UNDERLAY LAPPED &STAPLED ON INSIDE EDGE.
FLASHING TAPE OVER AS PERE2/AS1 100mm UP JAMBS
AIRSEAL ON PEFBACKING ROD TO ALLSIDES OF DOOR
CAVITY BATTENSuPVC STO JAMB FLASHING
7.5/9.0mm REBATEDSHEET - FIXED INACCORDANCE WITHSHEET MANUF. DETAILS
MS SEALANT
STOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SLIDING DOOR JAMB DETAIL
FCS 410
2017
SCALE 1:5
WALL UNDERLAY RETURNEDINTO OPENINGS & FLASHING
TAPE AT CORNERS
ALU.BIFOLD (open - in)DOOR JOINERY
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX
FLASHING TAPE OVER HEADFLASHING ONTO WALL UNDERLAY
ALUMINUM HEAD FLASHING TO EXTEND20mm MIN.PAST JAMBS WITH 15° SLOPEAND 10mm COVER AT DOOR HEADSEALANT REQUIRED FOR VERY HIGHAND EXTRA HIGH WIND ZONES
5
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRISSTOARMAT CLIP ON FOOT TRAY
WALL UNDERLAY20mm DRAINED & VENTED CAVITY7.5/9.0mm REBATED SHEET - FIXED INACCORDANCE WITH SHEET MANUF.DETAILSSTOARMAT RENDER SYSTEM
CAVITY BATTENS - AS PER MANUF.DETAILS
MIN.5mm GAP REQUIRED
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BIFOLD DOOR HEAD DETAIL
FCS 411
2017
SCALE 1:5
ALU.BIFOLD (open -in) DOOR JOINERY
50
LINE OF STOARMAT RENDERSYSTEM BEYOND - SHOWNDASHED
100
TURN-UP FLASHINGTAPE 100mm MIN.AT
TRIMMER STUDS
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604:2011
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BIFOLD DOOR THRESHOLD - CONCRETE FLOOR
FCS 412
2017
SCALE 1:5
5020
6mm MIN.OVERHANG
20mm DRAINED & VENTED CAVITY -AS PER SHEET MANUF. DETAILS
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRIS
STOARMAT CLIP ON FOOT TRAY
STOARMAT RENDER SYSTEM
MS SEALANTSTO uPVC SILL & JAMBFLASHING
ALU.BIFOLD (open -in) DOOR JOINERY
TURN-UP FLASHINGTAPE 100mm MIN.AT
TRIMMER STUDS
100
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604:2011
100mm DRAPE TODOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -REFER NZBC - Clause H1
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BIFOLD DOOR THRESHOLD - TIMBER FLOOR
FCS 413
2017
SCALE 1:5
ALU.BIFOLD (open - in)DOOR JOINERY
WALL UNDERLAY LAPPED &STAPLED ON INSIDE EDGE.
FLASHING TAPE OVER AS PERE2/AS1 100mm UP JAMBS
AIRSEAL ON PEFBACKING ROD TO ALLSIDES OF DOORCAVITY BATTENS
uPVC STO JAMB FLASHING(to be fixed before battens)
7.5/9.0mm REBATEDSHEET - FIXED INACCORDANCE WITHSHEET MANUF. DETAILS
MS SEALANT
STOARMAT RENDERSYSTEM
MS SEALANT
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BIFOLD DOOR JAMB DETAIL
FCS 414
2017
SCALE 1:5
LINE OF STOARMAT RENDERSYSTEM - SHOWN DASHED
SELECTED ALU.ENTRYDOOR JOINERY
DRAINAGE CHANNELFALL ALONG LENGTH
TO OUTLET
REMOVABLECHANNEL COVERCHANNEL COVERSUPPORT BRACKETS
SELECTED FLOORFINISH
FLASHING TAPE TAPE OVER SILL ANDMIN. 100mm UP FRAME FINISH AT
BOTTOM EDGE OF SILL SUPPORT BAR
100
NOTEREFER TO E2/AS1 FIG. 17 A,B,C & D INCLUDING SECTION 9.1.10
150
12
12m
m M
AX
.
200mm MIN.
WANZ SUPPORT BAR WITHVENTILATION/DRAINAGE HOLESINSTALLED TO MANUFACTURERSRECOMMENDATIONSUNDER DOOR TRIM BY BUILDER
FLASHING TAPE
CONTINUOUSAIR SEAL
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
LEVEL ENTRY THRESHOLD DETAIL
FCS 415
2017
SCALE 1:2
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX
WALL UNDERLAY
ADDITIONAL LAYER OFFLASHING TAPE LAPPEDOVER HEAD FLASHING
20mm DRAINED CAVITY
VENTED VERMINTRAY min. 15mm UP
STO uPVC CLIP-ONFOOT TRAY
ALUMINIUM HEADFLASHING WITH 15°SLOPE AND 10mm COVER
MIN. 5mm GAPREQUIRED
5
10
FLEXIBLE FLASHING TAPEINSTALLED OVER WALL
UNDERLAY AT CORNERS
10
1. HEIGHT WORK TO UNDERSIDE SOFFIT.MEASURE DOOR HEIGHT ON SITE &CHECK GARAGE DOOR SPECIFICATIONSFOR INTERNAL CORNER REQUIREMENTS
2. SEAL FLASHING FOR VERY HIGH orEXTRA HIGH WIND ZONES
3. IN EXTRA HIGH WIND ZONES INCREASEFLASHING COVER TO 60mm AND USE ARIGID UNDERLAY
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF. DETAILSSTOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
GARAGE DOOR - TIMBER HEAD
FCS 416
2017
SCALE 1:2
SELECTEDGARAGE DOOR
FLASHING TAPE OVERWALL UNDERLAY TOCORNERS OF OPENINGSPRE PRIMED H3.1JAMB LINER
10
REBATE IN GARAGE FLOORTO SUIT GARAGE DOOR
NOTE:MEASURE DOOR HEIGHT ON SITE & CHECK GARAGE DOORSPECIFICATIONS FOR INTERNAL CORNER REQUIREMENTS
MS SEALANT ONSTO JOINT SEALTAPE OR PEF ROD
6
WALL UNDERLAY20mm DRAINED
CAVITY
STO uPVC CLIP-ONFOOT TRAY
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITH
SHEET MANUF. DETAILSSTOARMAT RENDER
SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
GARAGE DOOR - TIMBER JAMB
FCS 417
2017
10
SCALE 1:2
5mm MIN.GAPFC SHEET TO FINISH 10mmMIN.PAST TO FORM DRIPEDGE
GARAGE DOOR TRIM -REFER TO GARAGE DOOR
MANUFACTURERSRECOMENDATIONS
NOTE:MEASURE DOOR HEIGHT ON SITE & CHECKGARAGE DOOR SPECIFICATIONS FORINTERNAL CORNER REQUIREMENTS
FIBRE CEMENT SOFFIT -STOARMAT RENDER
STO uPVC CLIP-ONFOOT TRAY
PURPOSE MADE METALFLASHING
WALL UNDERLAY20mm DRAINED CAVITY
VENTED VERMINTRAY min. 15mm UP
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF.DETAILSSTOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
GARAGE DOOR - RENDER HEAD DETAIL
fcs 418
2017
SCALE 1:2
SELECTED GARAGE DOORGARAGE DOOR TRIM
HEIGHT WORK TO UNDERSIDE OFSOFFIT. INSTALL TOMANUFACTURERS INSTRUCTIONS
STO CAVITY BATTENS
REBATE IN CONC.SLAB TOSUIT GARAGE DOOR
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHSHEET MANUF.DETAILS
STO PREMESHED CORNERBEAD OR S/S CNR ANGLE
FLASHING TAPE OVERWALL UNDERLAY TOCORNERS OF OPENINGS
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
GARAGE DOOR - RENDER JAMB DETAIL
FCS 419
2017
SCALE 1:5
FINISH SHEETS TO TOP EDGE
1. INSTALL METAL SADDLE FLASHING AT WALL JUNCTION2. ENSURE TOP IS TEMPORARILY WATERPROOFED BEFORE RENDERING3. METAL CAPPING EXCLUDING DRIP EDGE MUST OVERLAP SHEET BY
50mm MIN.IN LOW, MED or HIGH WIND ZONE,70mm MIN.IN VERY HIGH,90mm MIN.IN EXTRA HIGH WIND ZONES
4. INSTALL METAL CAPPING TO ALL ROOF PARAPETS
VA
RIE
S
VA
RIE
S
PROVIDE SEPARATION (ROOFUNDERLAY) TO METALCAPPING AND TIMBER
PRE FINISHED METAL CAPPINGTO PARAPET
5°5° MIN.FALL TO TOP OFPARAPET
STO JOINT SEAL TAPE ORSIMILAR TO CLOSE GAPS
9mm MIN.H3 PLYPACKED TO A FALL
WALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITH
SHEET MANUF. DETAILS
20mm DRAINEDCAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
PARAPET/METAL FLASHING DETAIL
FCS 500
2017
10°
NOTE:STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEENTESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858
WATERPROOF MEMBRANE AS REQUIRED BY E2/AS1
EXTRA HIGH WIND ZONES REQUIRE A RIGID UNDERLAY.
SCALE 1:5
OVERLAY OF STO FLEXYL MESHEDWATERPROOFING UNDER MESHCOAT TO TOP & SIDES, 75mmMIN.DOWNTURN
STO PREMESHED PVC ADJUSTABLECORNER ANGLES
WALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITH
SHEET MANUF. DETAILS
STOARMAT RENDER SYSTEM
20mm DRAINED CAVITY
10° MIN.FALL TO TOP OFPARAPET
H3.1 TIMBER PACKER CUT TOFALL, WITH ROOF UNDERLAY or
FLASHING TAPE
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
RENDERED PARAPET/BALUSTRADE DETAIL
FCS 501
2017
SCALE 1:5
WINDOW TRIMMINGSTUD
40mm MIN.40mm MIN.
150mm MIN.
TO FACE OF WINDOWOR DOOR JAMB STUD
7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITH
SHEET MANUF. DETAILSSTOARMAT RENDER
SYSTEM
20mm DRAINED CAVITY WALL UNDERLAY LAPPEDAROUND CORNER
DRAIN FORMED INCORNER50x50mm CORNER FLASHINGS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
PARAPET and/or ENCL.BALUSTRADE TO WALL - PLAN
FCS 502
2017
SCALE 1:5
WALL UNDERLAYWALL FRAMING
50x50mm BACKFLASHING
CAVITY BATTENS
9mm MIN.H3 PLYPACKED TO A FALL9mm MIN.H3 PLYPACKED TO A FALL
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FLEXIBLE FLASHING INSTALL - ISOMETRIC
FCS 503
2017
SCALE 1:5
LINE OF METAL SADDLEFLASHING BEHIND FIBRECEMENT CLADDINGRIVET THROUGH SEALANT
50x50mm CNR FLASHINGBEHIND CLADDING EXTENDEDTO BOTTOM OF WALL SHEETSON EACH BUILDING FACE
2 LINES OF SEALANT CAPPINGTO SADDLE FLASHING
WALL UNDERLAY
STOARMAT RENDERSYSTEM
9mm MIN.H3 PLYWOODTIMBER PACKER
CAPPING FLASHING
NOTE:LEAVE A 10mm GAP BETWEEN SADDLE FLASHING AND CAPFLASHING AT WALL TO ALLOW FOR EXPANSION AND SEAL WITHSEALANT UNDER CAP.
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
METAL SADDLE FLASHING & CAP INSTALL - ISOMETRIC
FCS 504
2017
SCALE 1:5
WALL UNDERLAYWALL FRAMING
APPLY STOFLEXYL MESHED WATERPROOFING OVER JOINTEDREBATED SHEETS. STOFLEXYL MESHED WATERPROOFING HASBEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OFAS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIRED BYE2/AS1
OVERLAY OF STOFLEXYL MESHEDWATERPROOFING UNDERSTOARMAT MESH COAT TO TOP &SIDES 75mm MIN.DOWNTURN
H3.1 TIMBER CAVITYBATTENS AS PER SHEETMANUF.DETAILS
H3.1 TIMBER PACKER CUTTO A FALL - MIN.10°
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
STOFLEXYL MESHED SADDLE FLASHING - ISOMETRIC
FCS 505
2017
SCALE 1:5
WALL UNDERLAYWALL FRAMING
APPLY STOFLEXYL MESHED WATERPROOFING OVER JOINTEDREBATED SHEETS. STOFLEXYL MESHED WATERPROOFING HASBEEN TESTED BY BRANZ TO MEET THE REQUIREMENTS OFAS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIRED BYE2/AS1
75
75
OVERLAY OF STOFLEXYL MESHEDWATERPROOFING UNDERSTOARMAT MESH COAT TO TOP &SIDES 75mm MIN.DOWNTURN
H3.1 TIMBER CAVITYBATTENS AS PER SHEETMANUF.DETAILS
H3.1 TIMBER PACKERCUT TO A FALL - MIN.10°
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
STOFLEXYL MESHED WATERPROOF CAPPING - ISOMETRIC
FCS 506
2017
SCALE 1:5
20mm DRAINED CAVITY
10°
NOTE:HANDRAIL REQUIRED WHERE BALUSTRADE IS UNDER1000mm
SELECTED MEMBRANE FINISHOVER H3 "C" FACED PLYWOODLAID TO 1:40MIN.FALL. GLUE &SCREW TO TIMBER JOISTS, ALLEDGES SUPPORTED ON TIMBER
20mm MIN.ANGLE FILLET
7.5/9.0mm REBATED SHEET - INSTALLAS PER MANUFACTERERS DETAILS
STOARMAT RENDER SYSTEM
150m
m M
IN.
ME
MB
RA
NE
UP
STA
ND
3515
OVERLAY OF STO FLEXYL MEMBRANEUNDER MESH COAT TO TOP & SIDES,
75mm MIN.DOWNTURN
STO PREMESHED PVC ADJUSTABLECORNER ANGLES IN STO ARMAT
CLASSIC COAT
STO uPVC CLIP-ON FOOT TRAY.
MEMBRANE TO RUN UP150mm MIN.AFFLMEMBRANE REINFORCING STRIPVENTED CAVITY BASECLOSER
WALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
10° MIN.FALL TO TOP OFBALUSTRADE
H3.1 TIMBER PACKER or 9mmMIN.PLYWOOD - CUT TO FALLMIN.10°
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET -INSTALL AS PER MANUF. DETAILS
STOARMAT RENDER SYSTEM
35mm MIN. TO FINISHED LEVEL OFDECK/ROOF
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BALUSTRADE/ENCLOSED DECK DETAIL
FCS 507
2017
SCALE 1:5
NOTE: - 100mm MIN. FROM FLOOR LEVEL FOR ENCLOSED DECKS - MIN.FALLS: 1:40 FOR DECKS, 1:30 FOR ROOFS & 1:100 FOR GUTTERS - ALLOW FOR TILES IF REQUIRED
3515
0
WALL UNDERLAY
STO uPVC CLIP-ON FOOTTRAY
MEMBRANE TO RUN UP150mm MIN.
MEMBRANEREINFORCING STRIP SELECTED MEMBRANE FINISH OVER H3
"C" FACED PLYWOOD LAID TO A 1:40 MIN.FALL. GLUE , SCREW TO TIMBER JOISTSALL EDGES SUPPORTED ON TIMBER.20mm MIN.ANGLE FILLET
20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET - INSTALLAS PER MANUFACTERERS DETAILS
STOARMAT RENDER SYSTEM
VENTED CAVITY CLOSER
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ENCLOSED DECK CROSS SECTION
MFCS 508
2017
35
SCALE 1:5
FLOORING
MS SEALANT TO TOPAND SIDES
LINE OF CANTILEVER JOIST -SHOWN DASHED
SOLID BLOCKINGBETWEEN JOISTS AS
REQUIRED
5mm MIN. GAP BETWEENRENDER SYSTEM AND
SADDLE FLASHING
5
5
35
MIN.COVER
12
12mm MAX.DRAINAGE
CONTINUOUS INTER-STOREYFLASHING
LINE OF CLADDING BETWEENJOISTS - SHOWN DASHED,CUT AROUND JOIST
CLADDING BELOW DECK
NOTE:REFER E2/AS1 Fig.16 FOR FLASHING REQUIREMENTS. PROVIDE 6-8mmWIDE SEALANT JOINT AT CLADDING/SADDLE FLASHING JUNCTION.
50mm MIN. SET DOWN FROM FLOOR OR THRESHOLD FORCANTILEVERED SLATTED DECKS
7.5/9.0mm REBATED SHEET20mm DRAINED CAVITYWALL UNDERLAY
STOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
CANTILEVERED SLATTED DECK
FCS 509
2017
SCALE 1:5
FINISHED DECK SURFACE
TIMBER FRAMINGTO NZS 3604
INTERNAL LINING
INSULATION TOEXTERIOR WALLS
FLOORING
FLOOR JOIST
12
M12 BOLTS - FIX AS PERPROJECT DETAILS
STOARMAT RENDERSYSTEM
20mm DRAINED CAVITYWALL UNDERLAY
50mmØ x3mm EPDMWASHERS AROUND FIXINGS
H3.2 STRING - REFER NZS3604FOR SIZEH3.2 PACKER
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
NON CANTILEVERED SLATTED DECK
FCS 510
2017
SCALE 1:5
50
DECKING
DECK JOIST
FLOORING
FLOOR JOIST
6mm OVERHANGRECOMMENDED TO AVOID
VARIANCES IN FOUNDATION
12mm MIN.GAP
6
uPVC VENT STRIP. MITRE CORNERS& KEEP CLEAR OF DEBRISSTOARMAT CLIP ON FOOTTRAY
CAVITY BATTENS AS PER MANUF.DETAILS
STOARMAT RENDER SYSTEM
9mm FIBRE CEMENT REBATED SHEETAS PER MANUF. DETAILS
20mm DRAINED & VENTED CAVITYWALL UNDERLAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INDEPENDENT SLATTED DECK
FCS 511
2017
SCALE 1:2
12mm MIN.
SCALE 1:2
DOUBLE MS SEALANT BRACKET FCS AND AGAIN AT BRACKET/MESHCOAT TRANSITIONS
NOTE: CARPENTER MUST FIT SHEET NEATLY WITH 8mm GAP
TIMBER BEAM
TIMBER FRAMINGAS PER NZS 3604
WALL UNDERLAY20mm DRAINED CAVITY
STOARMAT RENDER SYSTEM
FLASHING TAPE 100MM ONTO WALLUNDERLAY 25MM ONTO BRACKETMS SEALANT ALL ROUND
GALVANIZED OR STAINLESSSTEEL L BRACKET ENGINEEREDFOR LOAD
NOTE: 'L' BRACKET ENGINEERED FOR LOAD. FLASHING TAPE TOBUILDING UNDERLAY IN ACCORDANCE WITH E2/AS1 FIG. 68
7.5/9.0mm REBATED SHEET - FIX INACCORDANCE WITH SHEET MANUF.DETAILS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TIMBER BEAM / PERGOLA DETAIL
FCS 512
2017
SCALE 1:5
7525
A
A
EPDM WASHERS REQUIRED AROUNDFIXINGS AND PLATE TO PROVIDEWATERTIGHTNESS
RWH HEAD FIXED DIRECTLY ABOVE &BELOW SCUPPER PENETRATION
PRE FINISHED 0.55MM BMTSTEEL CUSTOM FOLDED ANDRIVETED RAIN WATER HEAD
MS SEALANT AROUNDOPENING/RHW FINISHED TOSTO FINISHING EDGE
MEMBRANE DRESSED OVER50x50mm ALU.ANGLE REBATEDINTO SUBSTRATE
50mm LIP
2550
50
SECTION A - A
200mm MIN.OUTLET THROUGH WALL
SELECTED MEMBRANE FINISHOVER H3 "C" FACED PLYWOODLAID TO 1:60MIN.FALL. GLUE &SCREW TO TIMBER JOISTS, ALLEDGES SUPPORTED ON TIMBER
20mm MIN.ANGLE FILLET
OUTLET THROUGH WALL
LINE OF MEMBRANELAPPED 50mm MIN.BEHINDWRAP UNDER CLADDING
LEAF GUARD
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
RWH/SCUPPER OPENING
FCS 513
2017
6mm MIN.
SCALE 1:10
NOTE:
IF BLOCKING IS MISSING, STAPLE WALL UNDERLAY TO SOFFITPLATE TO AVOID ANY VENTILATION GAPS
REFER TO E2/AS1 TABLE 1 FOR RISK LEVELS. EAVE FLASHINGREQUIRED WHEN FASCIA IS 100mm OR LESS FROM WALLCLADDING AND ROOF SLOPE IS LESS THAN 10° OR WIND ZONESARE VERY HIGH OR EXTRA HIGH
H3.1 PRE PRIMED &PAINTED FASCIA BOARD
PREFINISHED METALROOFING OVER ROOFUNDERLAY
PREFABRICATED TRUSSTOP CHORD OVERHANG
VARIES
MS SEALANT 6-8mm(before rendering)
SOFFIT LINING TOCLOSE OFF CAVITY
STOARMAT RENDER SYSTEM
WALL UNDERLAY
7.5/9.0mm REBATED FIBRECEMENT SHEET
20mm DRAINED CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FLAT SOFFIT/WALL JUNCTION
FCS 600
2017
SCALE 1:10
H3.1 PRE PRIMED &PAINTED FASCIA BOARD
PREFINISHED METAL ROOFINGOVER ROOF UNDERLAYPREFABRICATED TRUSSTOP CHORD OVERHANG
VARIES
MS SEALANT 6-8mm(before rendering)
STOARMAT RENDER SYSTEM
WALL UNDERLAY
7.5/9.0mm REBATED SHEET -FIXED IN ACCORDANCE WITHMANUF. DETAILS
20mm DRAINED CAVITY
SOFFIT LINING TOCLOSE OFF CAVITY
NOTE: REFER TO E2/AS1 TABLE 1 FOR RISK LEVELS. EAVEFLASHINGS REQUIRED WHEN FASCIA IS 100mm OR LESS FROMWALL CLADDING AND ROOF SLOPE IS LESS THAN 10° OR WINDZONES ARE HIGH OR VERY HIGH
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
RAKING SOFFIT/WALL JUNCTION
MFCS 601
2017
SCALE 1:10
MS SEALANT 6-8mm ON PEF ROD(over finished render)
NOTE:
REFER TO E2/AS1 TABLE 1 FOR RISK LEVELS. EAVE FLASHINGSARE REQUIRED WHEN FASCIA IS 100mm OR LESS FROM WALLCLADDING AND ROOF SLOPE IS LESS THAN 10°
H3.1 PRE PRIMED &PAINTED FASCIA BOARD
PREFINISHED METALROOFING OVER ROOFUNDERLAY
PREFABRICATED TRUSSTOP CHORD
50mm MIN.FASCIA COVER OVERRENDER SYSTEM
PRE FINISHED METAL E2 EAVES FLASHING,LAP 125mm MIN. UNDER ROOF CLADDING,TURN DOWN INTO GUTTER
50
BLOCKING TO CLOSE OFF CAVITYFROM ROOF SPACE
125
WALL UNDERLAY20mm DRAINED CAVITY
7.5/9.0mm REBATED SHEET FIXED INACCORDANCE WITH MANUF. DETAILSSTOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FACE FIXED FASCIA
FCS602
2017
SCALE 1:5
SELECTED FIBRECEMENT SOFFIT LINING
PREFINISHED METAL ROOFINGOVER ROOF UNDERLAY
HEMMED METAL FLASHING
6mm MAX.GAP WITH MSSEALANT
NOTE:
MAX.ANGLE OF SOFFIT RESTRICTEDTO BETWEEN 91°-115°
SOFFITS ARE TO BE FIXED AFTERCLADDING
6
STOARMAT RENDER SYSTEM
WALL UNDERLAY
7.5/9.0mm REBATED SHEET FIXED INACCORDANCE WITH MANF. DETAILS
20mm DRAINED CAVITY
50
35m
m c
over
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
RAKING SOFFIT (REVERSED)
FCS 603
2017
SCALE 1:5
SELECTED FIBRECEMENT SOFFIT LINING
PREFINISHED METAL ROOFINGOVER ROOF UNDERLAY
STO uPVC ADHESIVE SILLAND JAMB FLASHINGFINISH WITH MS SEALANT
NOTE:
MAX.ANGLE OF SOFFIT RESTRICTEDTO BETWEEN 91°-115°
STOARMAT RENDERSYSTEM
WALL UNDERLAY
7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITHMANUF. DETAILS
20mm DRAINED CAVITY
6
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
RAKING SOFFIT - STO uPVC CONTROL JOINT
FCS 604
2017
SCALE 1:2
15
5mm MIN.GAP SELECTED FIBRE CEMENTSOFFIT - STOARMAT RENDERSYSTEM WITH STO FINISHINGEDGE
E2/AS1 COMPLIANTFLASHING
STO uPVC FOOT TRAY
FLASHING TAPE OVER VERMINON TO WALL UNDERLAY
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATED SHEET -FIX AS PER MANUF. DETAILS
WALL UNDERLAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SOFFIT TO CLADDING DETAIL
FCS 605
2017
FASCIAEAVE SOFFIT
BUILDING UNDERLAY
STOARMAT RENDERSYSTEM
NOMINAL H3.1 20x45mmTIMBER CAVITY BATTENSFLASHING TAPE OR
BUILDING UNDERLAYOVER FLASHING
APRON FLASHING WITH TAPEREDSTOPEND TO DIVERT WATER INTOGUTTER. FC SHEET TO BECAREFULLY CUT OVER STOPEND &SEALED
APPLY MS SEALANT TO SEALFC BOARD TO FASCIA BOARD
STOP SPOUTING & FASCIAMIN.10mm CLEAR OF FINISHEDWALL CLADDING
NOTE:FOR DURABILITY OF FLASHINGS - REFER TABLE 20NZBC E2/AS1 DOCUMENT
ROOF UNDERLAY OMITTED FOR CLARITY
SCALE 1:10
50x50mm COVER BACKFLASHING BEHIND FASCIA &CLADDING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
GUTTER/WALL JUNCTION
FCS 606
2017
SCALE 1:2
SELECTED ALUMINIUMWINDOW/DOOR JOINERY
PROVIDE AIRSEAL ON PEFROD GAP 7.5-8mm APPROX.WALL UNDERLAY DRESSEDINTO OPENING
TIMBER LINTEL ASPER NZS 3604
100mm MIN.TO FACE OF CLADDING
SELECTED FIBRE CEMENTSOFFIT LINING18x18mm TIMBER BEADBETWEEN CLADDING ANDSOFFIT, PAINTED
LINE OF CLADDING BEYOND -SHOWN DASHED
varies
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
SOFFIT AT WINDOW/DOOR HEAD
FCS 607
2017
SCALE 1:5
ROOFSTRUCTURE
7.5/9.0mm REBATED SHEET OVER20mm DRAINED CAVITY - FIX INACCORDANCE TO MANUF. DETAILS
7535
REFER E2/AS1 TABLE 7
5mm
GAP
MAX
.FO
R N
OTC
HED
TUR
N-D
OW
N
STOARMAT RENDER SYSTEM
STO uPVC CLIP ON TRAY -REMOVE BACK TAB IF REQ.
uPVC CAVITY CLOSER
UNDERLAY OR FLASHING TAPELAPPED OVER APRON FLASHINGUPSTAND
PRE FINISHED METAL APRONFLASHINGPREFINISHED METAL ROOFINGOVER UNDERLAY
SELECTED ROOF WRAP
ROOF UNDERLAYCONTINUOUS TO TOP OFFLASHING
STOPEND TO RUN 10mmMIN.PAST CLADDING
NOTE:
STOPENDS REQUIRED AT ROOF to WALLJUNCTION TO DIVERT WATER FROM CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
APRON (TRANSVERSE) FLASHING
FCS 700
2017
SCALE 1:5
7535
ROOF RAFTER
REFER E2/AS1 TABLE 7
uPVC CAVITY CLOSER
7.5/9.0mm REBATED SHEET OVER 20mmDRAINED CAVITY - FIX IN ACCORDANCEWITH MANUF. DETAILSSTOARMAT RENDER SYSTEM
STO uPVC CLIP ON TRAY -REMOVE BACK TAB IF REQ.
UNDERLAY OR FLASHING TAPELAPPED OVER APRONFLASHING UPSTAND
APRON FLASHING WITH TAPEREDDIVERTER FLASHING TO DIRECT WATERINTO GUTTER. CLADDING TO BECAREFULLY CUT OVER STOPEND &SEALED
NOTE: PROVIDE DIVERTER FLASHING AT ROOF TOGUTTER JUNCTION TO DIVERT WATER INTO THEGUTTER - Refer Drawing FCS 606 (Monotek)
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
APRON (PARALLEL) FLASHING
FCS 701
2017
SCALE 1:5
20mm DRAINED CAVITY
5mm
GAP
MAX
.FO
R N
OTC
HED
TUR
N-D
OW
N
7.5/9.0mm REBATED SHEETS - FIXIN ACCORDANCE WITH MANUF.DETAILS
VENTED CAVITY CLOSURE -STO uPVC CLIP ON TRAY
STOARMAT RENDER SYSTEM
PREFINISHED METALAPRON FLASHINGPREFINISHED METALROOFING OVER UNDERLAY
SELECTED ROOF UNDERLAY
ROOF UNDERLAYCONTINUOUS TO TOP OFFLASHING
NOTE: CONTRACTOR TO FIT STOPEND FLASHING & HEMMEDFLASHING FOR FASCIAS 50mm BEHIND CLADDING, 50mm BEHINDFASCIA. STO CONTRACTOR TO APPLY FINISHED SEALANT JOINTBETWEEN FASCIA & PLASTER. UNDERLAY or FLASHING TAPE OVERFLASHING UPSTAND.
PARAPETS - REFER 500 SERIES - PARAPET DETAILS
50mm MIN.FASCIA BACKFLASHING - SHOWN DASHED
STOPEND FLASHING
7535 REFER E2/AS1 TABLE 7
5mm
GAP
MAX
.FO
R N
OTC
HED
TUR
N-D
OW
N
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTERSTOREY TRANSVERSE (APRON) ROOF STOPEND
FCS 702
2017
SCALE 1:5
STOP END 10mm PASTFINISHED CLADDING
20mm DRAINEDCAVITY
MEMBRANE OVER COVERBOARD WITH DRIP EDGE
10
10
7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITHMANUF. DETAILS
STOARMAT RENDER SYSTEM
35
75
150
FASCIA 10mm SHORT OFFINISHED CLADDING WITH MSSEALANT JOINT
BACK FLASHING 50mm BEHINDFASCIA & CLADDING
STO STICK ON CONNECTOR or MSSEALANT JOINT ON PEF RODBETWEEN STOPEND AND CLADDING
ROOFING MEMBRANE OVER METALSTOPEND. STOPEND TO EXTEND 10mmMIN.PAST FINISHED WALL
ROOFING MEMBRANE 150mmMIN.UPSTAND, 75mm CLADDING COVER,
CLADDING 35mm MIN. ABOVE MEMBRANE
110
3476
150
10
BATTEN TO BLOCK CAVITY
IF MEMBRANE
IF ROOF
CLADDING
ROOF/DECK NOTE: MEMBRANE NOT SHOWN ON STOPEND FOR CLARITY
A = CAVITY & FINISHED CLADDING + 10mm
75mm MIN.A
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTER-STOREY FLAT (MEMBRANE)ROOF STOPEND
FCS 703
2017
SCALE 1:5
WALL UNDERLAY
TIMBER FRAMING TONZS 3604
20mm DRAINEDCAVITY
7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITHMANUF. DETAILSSTOARMAT RENDER SYSTEM
FASCIA 10mm SHORT OFCLADDING MS SEALANT JOINTFASCIA / CLADDING BACKFLASHING, MIN 50mm COVERH3.1 PRE PRIMED & PAINTEDFASCIA/BARGE BOARD -SHOWN DASHED
10
PRE FINISHED METAL FLASHINGOVER FASCIA
APRON FLASHINGSTOPEND
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTER-STOREY ROOF STOPEND - PLAN VIEW
FCS 704
2017
7550
DRESS WALLUNDERLAY OVER
GUTTER LINING
SELECTED GUTTER LINING CARRIEDOVER ANTI-PONDING BOARD AND UPABUTMENT FRAME ON NOG TO SUIT
GUTTER BOARD AT ABUTMENTON NOGS TO SUIT
ANTI-PONDING BOARDLAID TO A FALL
ROOF UNDERLAYCARRIED DOWNOVER GUTTER LINING
MASONRYROOFING TILE
SCALE 1:5
STO uPVCCLIP ON TRAY
100mm MIN.
20mm DRAINED CAVITY7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE TOMANUF. DETAILSSTOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ROOF PENETRATION/GUTTER (Masonry Tile) DETAIL
FCS 705
2017
SCALE 1:5
80mm MIN. 80mm MIN.
20m
m M
IN.
110m
m
NOTE: WHERE GUTTER FINISHES WITHIN THE LENGTH OF THE WALL, STEP LOWER PART OFGUTTER OUT TO 10mm PAST THE CLADDING LINE, WHILE MAINTAINING REQ.CLEARANCES, TOALLOW THE GUTTER TO FEED INTO THE LOWER EAVES GUTTER.- REFER Fig: 37 & Fig: 50 Incl.Section 8.1.6.2
35m
m G
AP
75m
m M
IN.C
OV
ER
MIN
.TO
TAL
WALL UNDERLAY OVERGUTTER UPSTANDPREFINISHED METAL GUTTER
STO uPVC VENTED CAVITYCLOSER & STO uPVC CLIP ONTRAY
20mm DRAINED CAVITY7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITHMANUF. DETAILSSTOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
PARALLEL ROOF/HIDDEN GUTTER
FCS 706
2017
SCALE 1:5
WALL UNDERLAY20mm DRAINED CAVITY7.5/9.0mm REBATED SHEET -FIX IN ACCORDANCE WITHMANUF. DETAILSSTOARMAT RENDER SYSTEM
6mmMAX.GAP
50/90mm LAP REFER NZBC,TABLE 7 E2/AS1 FORFLASHING DIMENSIONS
H3.1 PRE PRIMED & PAINTEDFASCIA/BARGE BOARD
PRE FINISHED METALFLASHING
MS SEALANT ON PEF ROD FOREXPOSED SITES
ALLOW FOR STO uPVC CLIPON FLASHING
PRE FINISHED METAL ROOFINGOVER ROOF UNDERLAY
50 c
over
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FACE FIXED FASCIA/BARGE
FCS 707
2017
SCALE 1:5
20mm DRAINED CAVITY
TIMBER FRAMINGTO NZS3604
SELECTED MEMBRANE FINISHOVER H3 "C" FACED PLYWOOD LAIDTO 1:30 MIN.FALL. GLUE & SCREWTO TIMBER JOISTS, ALL EDGESSUPPORTED ON FRAMING
TAKE BOTH LAYERS 6mm PASTS/S ANGLE TO FORM DRIP EDGE
MIN.5mm RADIUSTO PLYWOOD
PREFINISHED METAL SPOUTINGAND BRACKETS
WALL UNDERLAY
50mm MIN. LAP REFER E2/AS1
H3.1 PRE PRIMED & PAINTEDFASCIA/BARGE BOARDMS SEALANT ON PEF ROD
STOARMAT RENDERSYSTEM
7.5/9.00mm REBATED SHEET -FIX IN ACCORDANCE WITHMANUF. DETAILS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FACE FIXED FASCIA/MEMBRANE ROOF
FCS 708
2017
SCALE 1:5
ROOFSTRUCTURE
PREFINISHED METALFLASHING, TURN DOWN TOSUIT PROFILEPREFINISHED METALROOFING OVER UNDERLAYSELECTED ROOF WRAP
50/90mm LAP REFER NZBC,TABLE 7 E2/AS1 FORFLASHING DIMENSIONSH3.1 PRE PRIMED & PAINTEDFASCIA/BARGE BOARD
PRE FINISHED METALFLASHING
MS SEALANT ON PEF ROD FOREXPOSED SITES
REFER E2/AS1 TABLE 7
WALL UNDERLAY20mm DRAINED CAVITY
7.5/9.0mm MONOTEKSTOARMAT RENDER SYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
ROOF/WALL RIDGE
FCS 709
2017
PENETRATION APRON FLASHINGHEM FOLD UNDER ROOFING
SEPARATE ROOFING SHEETOVER
MIN. UPSTAND 110mm
SIDE COVER= 2 CRESTS
STOARMAT RENDER SYSTEMWITH PREMESHED EXTERNALCORNERS
H3.1 TIMBER CAVITY BATTENSFIBRE CEMENT SHEETWALL CLADDING
35mm GAP BETWEENCLADDING AND FLASHING
SET ONE CORNER OF UPSTANDHIGHER UP ROOF PLANE
TO PROVIDE CROSS FALL
250mm MIN.
110
35
130 - 200
130 - 200
COVER 130 - 200mm MAX.REFER TO E2/AS3 Table 7
110
NOTE:SUITABLE FOR RECTANGULAR PENETRATIONS UP TO 1200mmWIDE.ROOF PITCH MUST BE 10° or HIGHER - REFER TO E2/AS1TABLE 9 or 17 FOR MAX.ROOF LENGTH ABOVE PENETRATIONS.BLOCKING REQUIRED FOR PENETRATIONS OVER 200mm
FRAMED CHIMNEYSCALE 1:20
UNDERLAY SEPARATOR BETWEENFLASHING AND FRAMING. FRAME TO
SUPPORT FLASHING
PREFINISHED METAL ROOFINGOVER UNDERLAY
SELECTED ROOF WRAPE2/AS3 COMPLIANT METAL APRONFLASHING
STO uPVC CLIP ON FOOTTRAY
SECTION/FRAMED CHIMNEYSCALE 1:10
7535
3575
110
110
STOARMAT RENDER SYSTEM OVER 7.5-9.0mmFIBRE CEMENT SHEET
20mm DRAINED CAVITYWALL UNDERLAY LAPS OVER
FLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FRAMED CHIMNEY OR PENETRATION UP TO 1200mm
FCS 710
2017
SCALE 1:2
WALL UNDERLAYCONTINUOUS AROUNDCORNER
H3.1 SCRIBER TO SUITWEATHERBOARD PROFILE
SELECTED HORIZONTALTIMBER WEATHERBOARDSOVER 20mm DRAINEDCAVITY
50m
m M
IN.C
OV
ER
10mm MIN.GAP
50mm x 50mm BACKFLASHING
NOMINAL 20x45mm H3.1TIMBER CAVITY BATTEN7.5/9.0mm REBATEDSHEETSTOARMAT RENDER SYSTEMWITH STO uPVC CLIP ONTRAY
MIN.ex 25mm COVER BOARDWITH 6x6mmWEATHERGROOVES
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
WEATHERBOARD/FC SHEET EXT.CORNER - OPT 1
FCS 800
2017
SCALE 1:2
PURPOSE MADEFLASHING
5mm
50mm COVER
50m
m
NOTE: IF A TIMBER SCRIBER REQUIREDEXTEND FLASHING ACCORDINGLY
SELECTED HORIZONTALTIMBER WEATHERBOARDSOVER 20mm DRAINEDCAVITY
STO uPVC CLIP ON TRAY
MS SEALANT
WALL UNDERLAYCONTINUOUS AROUNDCORNER
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATEDFIBRE CEMENT SHEET
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
WEATHERBOARD/FC SHEET EXT.CORNER - OPT 2
FCS 801
2017
SCALE 1:2
E2/AS1 COMPLIANTFLASHING
5mm
50m
m
NOTE: IF A TIMBER SCRIBER REQUIREDEXTEND FLASHING ACCORDINGLY
BUILDING UNDERLAYCONTINUOUS AROUNDCORNER
STO uPVC CLIPON TRAY
MS SEALANT
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATEDFIBRE CEMENT SHEET
SELECTED HORIZONTALTIMBER WEATHERBOARDSDIRECT FIXED
50mmCOVER
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
W'BOARD/FC SHEET EXT.CORNER - DIRECT FIX
FCS 802
2017
SCALE 1:2
WALL UNDERLAY CONTINUOUSAROUND CORNER
50m
m M
IN.
50mm MIN.
COVER
CO
VE
R
NOMINAL 20X45mm H3.1TIMBER CAVITY BATTEN -FIX IN ACCORDANCEWITH MANUF.DETAILS
SELECTED HORIZONTAL TIMBERWEATHERBOARDS OVER 20mmDRAINED CAVITY
MS SEALANT ON PEF ROAD
E2/AS1 COMPLIANT FOLDEDMETAL FLASHING
7.5/9.0mm REBATED SHEET
STOARMAT RENDER SYSTEMWITH CLIP ON FLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
WEATHERBOARD/FC SHEET INT.CORNER - OPT 1
FCS 803
2017
SCALE 1:2
WALL UNDERLAYCONTINUOUS AROUNDCORNER
SELECTED HORIZONTAL TIMBERWEATHERBOARDS OVER 20mmDRAINED CAVITY
COVER
CO
VE
R
E2/AS1 COMPLIANT FOLDEDFLASHING
50mm MIN.
50m
m M
IN.
H3.1 SCRIBER TO SUITEWEATHERBOARD PROFILE
MS SEALANT ON PEF ROD
NOMINAL 20x45mm H3.1TIMBER CAVITY BATTEN -FIX IN ACCORDANCEWITH MANUF.DETAILS7.5/9.0mm REBATED SHEETSTOARMAT RENDER SYSTEMWITH STO uPVC CLIP ONFLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
WEATHERBOARD/FC SHEET INT.CORNER - OPT 2
FCS 804
2017
SCALE 1:2
WALL UNDERLAY CONTINUOUSAROUND CORNER
50m
m M
IN.
50mm MIN.
COVER
NOMINAL 20X45mm H3.1 TIMBER CAVITYBATTEN - FIX IN ACCORDANCE WITHMANUF.DETAILS
SELECTED HORIZONTAL TIMBERWEATHERBOARDS - DIRECT FIXED
MS SEALANT ON PEF ROAD
E2/AS1 COMPLIANT FOLDEDMETAL FLASHING
7.5/9.0mm REBATED SHEET
STOARMAT RENDER SYSTEMWITH CLIP ON FLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
W'BOARD/FC SHEET INT.CORNER - DIRECT FIX
FCS 805
2017
SCALE 1:2
50mm MIN. 50mm MIN.COVER
WALL UNDERLAY
SELECTED HORIZONTAL TIMBERWEATHERBOARDS OVER 20mmDRAINED CAVITY
E2/AS1 COMPLIANT TOP HATMETAL FLASHING
COVER
MS SEALANT ON PEF ROD
NOMINAL 20x45mm H3.1TIMBER CAVITY BATTENFIXED IN ACCORDANCE
WITH MANUF.DETAILS7.5/9.0mm REBATED SHEET
STOARMAT RENDERSYSTEM WITH STO
uPVC CLIP ON TRAY
40mm
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO VENTCLAD/MONOTEK
STOARMAT RENDER SYSTEM
VERTICAL JOINT - WEATHERBOARD/FC SHEET
FCS 806
2017
MS SEALANT OR STO JOINTSEAL TAPE
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
35m
m M
IN.
CO
VE
R35
mm
MIN
.C
OV
ER
BEVEL-BACK TIMBERWEATHERBOARDS TO NZS 3617OVER 20mm DRAINED CAVITY
FLASHING TAPE LAPPED OVERHEAD FLASHING
E2/AS1 COMPLIANT FLASHING
MIN. 10mm GAP
CAVITY CLOSER POSITIONEDTO GIVE 15mm MIN.DRIPEDGE TO CLADDING
STOARMAT RENDER SYSTEM WITHSTO uPVC MESHED FINISHINGEDGE
7.5/9.0mm REBATED FIBRECEMENT SHEET
20mm DRAINED CAVITY
1. IN HIGH WIND ZONES INCREASEFLASHING COVER TO 60mm MIN.ANDUSE A RIGID UNDERLAY
10
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZONTAL JUNCTION W'BOARD/FC SHEET
FCS 807
2017
SCALE 1:2
35m
m M
IN.
CO
VE
R35
mm
MIN
.C
OV
ER
BEVEL-BACK TIMBERWEATHERBOARDS TO NZS 3617OVER 20mm DRAINED CAVITY
FLASHING TAPE LAPPED OVERHEAD FLASHING
CAVITY CLOSER POSITIONEDTO GIVE 15mm MIN.DRIPEDGE TO CLADDING
H3.1 SLOPED HORIZONTALPACKERS AS REQUIRED
RIGID AIR BARRIERTO GABLE END
H3.1 CONTINUOUS HORIZONTALTAPERED PACKER BEHINDCAVITY CLOSER TO RESTRICTAIRFLOW
ALU.INTER-STOREYFLASHING, STOPEND, 15°SLOPE & 35mm MIN.COVER
MS SEALANT TORENDER/FLASHING
7.5/9.0mm REBATED SHEETSTOARMAT RENDER SYSTEMWITH STO uPVC PRE MESHEDFINISHING EDGE
20mm DRAINED CAVITY
1. IN HIGH WIND ZONES INCREASEFLASHING COVER TO 60mm MIN.ANDUSE A RIGID UNDERLAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
GABLE END - WEATHERBOARD/FC SHEET
FCS 808
2017
SCALE 1:2
STO uPVC CLIP ON TRAYWITH MS SEALANT OVERPEF ROD
SELECTED BRICK VENEER40mm MIN.CAVITY
TIMBER FRAMINGTO NZS 3604
10
NOMINAL 20x45mm H3.1TIMBER CAVITY BATTENSINSTALLED INACCORDANCE WITHMANUF.DETAILSFLASHING TAPE AROUNDUNDERLAY 75mm MIN.
7.5/9.0mm REBATED FIBRECEMENT SHEET
STOARMAT RENDERSYSTEM
20mm DRAINED CAVITY
WALL UNDERLAY TO BECONTINUOUS AROUNDCORNER
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BRICK VENEER/FC SHEET EXTERNAL CORNER
FCS 810
2017
SCALE 1:2
WALL UNDERLAY CONTINUOUSAROUND CORNERS
TIMBER FRAMINGTO NZS 3604
50m
m M
IN.
50m
m M
IN.
CO
VE
RC
OV
ER
MS SEALANTOVER PEF ROD
SELECTED BRICK VENEER 40mmMIN.CAVITY
E2/AS1 COMPLIANT FLASHING,HEM TO BOTH ENDS
7.5/9.0mm REBATED FIBRECEMENT SHEET OVER 20mmDRAINED CAVITY
STOARMAT RENDER SYSTEM
STO uPVC CLIP ON TRAY -REMOVE DRIP EDGE
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BRICK VENEER/FC SHEET INTERNAL CORNER OPT. 1
FCS 811
2017
SCALE 1:2
STO uPVC CLIP ON FLASHING MS SEALANT OVERSTO JOINT SEAL TAPE
SELECTED BRICK VENEER 40mmMIN.CAVITY
WALL UNDERLAY CONTINUOUSAROUND CORNERS
TIMBER FRAMINGTO NZS 3604
7.5/9.0mm REBATED FIBRECEMENT SHEETSTOARMAT RENDER SYSTEM
20mm DRAINED CAVITY
BACK FLASHING TO CORNER
50
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BRICK VENEER/FC SHEET INTERNAL CORNER - OPT 2
FCS 812
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
STOARMAT MIRALRENDER SYSTEM ONSELECTEDCONCRETE BLOCK
STO PREMESHEDCORNER
STO uPVC CONTROLJOINT WITH MSSEALANT IN STOARMATMESHED PLASTER
DPC
10
7.5/9.0mm REBATEDSHEET
STOARMAT RENDERSYSTEM
20mm DRAINEDCAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
EXTERNAL CORNER CONC.BLOCK/FC SHEET
FCS 830
2017
SCALE 1:2
USE STO S - PROTECT COATING SYSTEM FOR CLEAR FINISHED CONCRETE BLOCK
DPC
STOARMAT MIRAL RENDERSYSTEM or S-PROTECT CLEARON SELECTED CONCRETEBLOCK
E2/AS1 COMPLIANT BACKFLASHING CHASED & SEALEDINTO CONC.BLOCK
MS SEALANTOVER PEF ROD
7.5/9.0mm REBATED SHEETSTOARMAT RENDER SYSTEMWITH STO uPVC CLIP ON orFINISHING EDGE
20mm DRAINED CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTERNAL CORNER CONC.BLOCK/FC SHEET
FCS 831
2017
SCALE 1:2
STOARMAT MIRAL RENDERSYSTEM ON SELECTEDCONCRETE BLOCK SERIESSTO uPVC CONTROL JOINTALLOW 10mm GAP IN FCSHEET
10mm
DPC
7.5/9.0mmREBATED SHEET
STOARMAT RENDERSYSTEM
20mm DRAINED CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
VERTICAL JOINT CONC.BLOCK/FC SHEET
FCS 832
2017
11m
m M
IN.
SCALE 1:2
DPC
FORM RENDERED REBATE INCONC.BLOCK WITH 15° SLOPE
STOARMAT MIRAL RENDERSYSTEM TO SELECTEDCONC.BLOCK
STO FLEXYL MESHEDWATERPROOF UPTURN/DOWNTURN CONC.BLOCKREBATE SURFACES, RENDERTOP OF REBATE
6
5mm
GAP
15
7.5/9.0mm REBATED SHEET
STOARMAT RENDERSYSTEM
20mm DRAINED CAVITY
uPVC VENTED BASE CAP
STO uPVC CLIPON FOOT TRAYREMOVE BACK TAB IFREQUIRED
50m
m m
in.
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZONTAL JUNCTION CONC.BLOCK/FC SHEET
FCS 833
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
WALL UNDERLAY CONTINUOUSAROUND CORNERS,POLYPROPYLENE FLASHING TAPEAPPLIED TO PROTECT WALLUNDERLAY 75mm MIN.WIDE
NOTE: FINISH STO CLADDING SYSTEM BEFOREINSTALLING STONE CLADDING
PROPRIETARY MANUF.STONECLADDING FIXED ACCORDINGTO MANUF.CONSTRUCTIONDETAILS
MS SEALANT ONPEF ROD
SEALANT TOJUNCTION
STO uPVC CLIPON FLASHING
7.5/9.0mm REBATED FCSHEET
20mm DRAINED CAVITY
STOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
EXT.CORNER - MANUF.STONE/FC SHEET
FCS 840
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
WALL UNDERLAYCONTINUOUS AROUNDCORNERS
STO PREMESHED PVCCNR.ANGLES ON ALLEXT.CNRS
E2/AS1 COMPLIANTBACK FLASHING
PROPRIETARY STONE VENEER CLADDINGFIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
2mm GAP BETWEENSHEETS7.5/9.0mm REBATED SHEET
20mm DRAINED CAVITY
STOARMAT RENDERSYSTEM WITH STO uPVC
CLIP ON TRAY or FINISHINGEDGE
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
BOXED EXT.CORNER - STONE VENEER/FC SHEET
FCS 841
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
DOUBLE STUD REQUIRED
E2/AS1 COMPLIANT 50x50mmCORNER FLASHING
8mm BETWEEN SHEETS, MSSEALANT JOINT
NOTE: INSTALL FC SHEET AND FINISH STOCLADDING SYSTEM BEFORE INSTALLING STONE
8
MS SEALANT ON PEF RODPROPRIETARY MANUF.STONE CLADDINGFIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
STO uPVC CLIP ON TRAY7.5/9.0mm REBATED FC SHEET
STOARMAT RENDER SYSTEM
20mm DRAINED CAVITY
WALL UNDERLAY CONTINUOUSAROUND CORNERS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INTERNAL CORNER - MANUF.STONE/FC SHEET
FCS 842
2017
SCALE 1:2
50mm MIN. 50mm MIN.COVER COVER
MS SEALANT ON PEF ROD
E2/AS1 COMPLIANTBACK FLASHING
PROPRIETARY MANUF.STONE CLADDINGOVER FIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
7.5/9.0mmREBATED SHEET
STOARMAT RENDERSYSTEM WITH STO uPVC
CLIP ON TRAY
20mm DRAINED CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
VERTICAL JUNCTION - MANUF.STONE/FC SHEET
FCS 843
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
MS SEALANT ON PEF RODor STO JOINT SEAL TAPE
SCHIST OR STONE VENEER CLADDINGFIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
INSTALL FC SHEET ANDFINISH STOARMATCLADDING SYSTEMBEFORE INSTALLINGSCHIST OR STONE
WALL UNDERLAYCONTINUOUS AROUNDCONERS,POLYPROPYLENE FLASHINGTAPE APPLIED TOPROTECT WALLUNDERLAY 75mmMIN.WIDE
STO uPVC CLIPON FLASHING
MS SEALANT/STOSEAL TAPE
STOARMAT RENDERSYSTEM
20mm DRAINEDCAVITY7.5/9.0mm REBATEDFC SHEET
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
EXT.CORNER - SCHIST or STONE VENEER/FC SHEET
FCS 844
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
NOTE: INSTALL FC SHEET AND FINISH STOCLADDING SYSTEM BEFORE INSTALLING STONE
E2/AS1 COMPLIANT BACK FLASHINGWITH 50mm MIN. COVER TOCLADDING
8mm BETWEENSHEETS, MS SEALANT
DOUBLE STUD REQUIRED
50m
m M
IN.
8
MS SEALANT ON PEF ROD or STOJOINT SEAL TAPESCHIST OR STONE VENEER CLADDING ANFIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
7.5/9.0mm REBATED FC SHEET
STOARMAT RENDERSYSTEM
20mm DRAINED CAVITY
WALL UNDERLAY CONTINUOUSAROUND CORNERS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
INT.CORNER - SCHIST or STONE VENEER/FC SHEET
FCS 845
2017
SCALE 1:2
MS SEALANT ON PEF ROD
E2/AS1 COMPLIANT BACK FLASHINGWITH 50mm MIN.CLADDING COVER
SCHIST OR STONE VENEERCLADDING FIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
50mm COVER 50mm COVER
7.5/9.0mmREBATED SHEET
STOARMATRENDER SYSTEM
CAVITY BATTENS
STO uPVC CLIP ONFLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
VERTICAL JUNCTION - SCHIST or STONE VENEER/FC SHEET
FCS 846
2017
SCALE 1:2
NOTE:SCHIST OR STONE VENEERCLADDING FIXED ACCORDING TOMANUF.CONSTRUCTION DETAILS
TOP PIECE OF SCHIST OR STONEMUST EITHER BE PLACED OR CUT SOA 15° SLOPE IS FORMED ON THE SILL
10m
mG
AP
35m
mC
OV
ER
STO uPVC CLIP ON FLASHING
VERMIN TRAY - BY OTHERS
TAPE OVER FLASHING
7.5/9.0mm REBATED FCSHEET
STOARMAT RENDER SYSTEM
20mm DRAINED CAVITY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HORIZ.JUNCTION - SCHIST or STONE VENEER/FC SHEET
FCS 847
2017
SCALE 1:2
5mm
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX
TIMBER LINTEL ASPER NZS 3604
INTERNAL LINING
ARCHITRAVE ORSLIMLINE DETAIL
TIMBER WINDOW HEAD -PROFILE TO NZS 3610
FLEXIBLE FLASHING TAPEINSTALLED OVER WALL
UNDERLAY AT CORNERS ASPER E2/AS1
ALUMINIUM HEADFLASHING MIN.0.55 BMT,STOP ENDED WITH 15°SLOPE AND 20mm COVER
FIBRE CEMENT SHEET TO OVERHANG VERMIN TRAY BY 15mm min. FIT CLIPON TRAY AND LEAVE 5mm min.CLEARANCE TO HEAD FLASHING.PROPRIETRY ALUM. HEAD FLASHING TO COVER WINDOW FACING BY 20mm SLOPED 15° WITH min. 35mmUPSTAND TAPED TO WALL UNDERLAYALLOW HEAD FLASHING TO PASS JAMBS BY 30mm BEND UP ENDS BY 20mm TO CREATE STOP ENDS IN CAVITYFLASHING TAPE SYSTEM TO BE INSTALLED AROUND JOINERY OPENINGS AS PER E2/AS1 BY BUILDER.
20
PROVIDE FIRM SUPPORT(TIMBER PACKER) TOFACING
7.5/9.00mm REBATED FCSHEET
STOARMAT RENDERSYSTEM
20mm DRAINED & VENTEDCAVITY - BATTENS AT 450mmMAX.CTRS.
VENTED VERMIN TRAY min.15mm UPSTO uPVC CLIP-ON TRAYWITH MIN 5mm GAP
PROPRIETARY TAPE ORALTERNATIVELY ADDITIONALLAYER OF BUILDING WRAPOVER HEAD FLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TIMBER WINDOW JOINERY - HEAD DETAIL
FCS 870
2017
SCALE 1:2
INTERNAL LINING
TIMBER TRIM
CONTINUOUS PACKING
TIMBER FRAMINGTO NZS 3604
MS SEALANT
WALL UNDERLAY TURNEDINTO FRAMING REVEALS
AND TAPED AT CORNERS
SILL FLASHING WITHSTOP-END, LAPPEDUNDER JAMB PACKER
TIMBER WINDOW SILLTO NZS 3610
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX
FLEXIBLE FLASHING TAPEINSTALLED OVER WALL
UNDERLAY AT CORNERS
10
25
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATED FCSHEET
VERTICAL CAVITYBATTENS
EDGE OF SHEET TO BESEALED BEFOREWINDOW IS INSTALLED
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TIMBER WINDOW JOINERY - SILL DETAIL
FCS 871
2017
SCALE 1:2
TIMBER JAMB -PROFILE TO NZS 3610
INTERNAL LINING
AIRSEAL GAP 7.5-8mmAPPROX
ARCHITRAVE ORSLIMLINE DETAIL
JAMB PACKER TOSUIT REBATE
LINE OF HEADFLASHING
LINE OF SILL FLASHING -LAPPED UNDER JAMBPACKING
WALL UNDERLAY TURNEDINTO FRAMING REVEALS
AND TAPED AT CORNERS
TIMBER FRAMINGTO NZS 3604
ALUM. JAMB BACK FLASHINGNOTCHED INTO TIMBERWINDOW SILL JOINERY WITHMS SEALANT TO FINISH
STO STICK ON JOINERYCONNECTOR AT SILL FORPLASTER
STOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TIMBER WINDOW JOINERY - JAMB DETAIL
FCS 872
2017
SCALE 1:2
TIMBER PACKER TOSUPPORT FLOORING
E2/AS1 COMPLIANT SILLFLASHING STOP ENDEDAND LAPPED UNDER JAMBPACKERS
MS SEALANT
PROPRIETARY FLASHINGTAPE TO RUN 100mm UPJAMBS
TIMBER DOOR SILL TONZS 3610
50m
m M
IN.
15
WALL UNDERLAY TURNEDINTO FRAMING REVEALS ANDTAPED AT CORNERS
20mm DRAINED & VENTEDCAVITY - BATTENS AT450mm MAX CTRS.
BOUNDARY JOIST20mm CAVITY BATTENSFIXED IN ACCORDANCE
AS PER MANUF.DETAILS
AIR SEAL
uPVC VENT STRIP. MITRECORNERS & KEEP CLEAROF DEBRIS
STOARMAT CLIP ON FOOTTRAY
7.5/9.0mm REBATED FC SHEET
STOARMAT RENDERSYSTEM
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604:2011
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TIMBER DOOR JOINERY - TIMBER FL.THRESHOLD
FCS 873
2017
SCALE 1:2
TIMBER SILL TONZS 3610
TIMBER SILL TRIM TOBLOCK CAVITY
UPSTAND TO SUITFLOOR FINISHES
NOTE: SILL TO BE SNUGFIT AS AIR SEAL
REBATE OR CUT SLAB -RENDER TO SUIT SILL
SLOPE & WATERPROOFWITH STO FLEXYL
PROPRIETARY FLASHINGTAPE 100mm UP JAMB AT
STUD AS PER E2/AS1 100m
m M
IN. U
P J
AM
B
DPC
STO uPVC CLIP ONFLASHING
NOTE:FOR CLEARANCE BETWEENCLADDING AND ADJACENT GROUND- REFER NZS3604
STOARMAT RENDERSYSTEM
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
TIMBER DOOR JOINERY - CONC. FL.THRESHOLD
FCS 874
2017
SCALE 1:2
FLASHMAN EXTRUDED ALUMINIUMONE PIECE CAVITY CLOSURE ANDHEAD FLASHING WITH STOP END(SHOWN DASHED)
5
AIRSEAL OVER PEFROD GAP 7.5-8mm
APPROX
TIMBER LINTEL ASPER NZS 3604
INTERIOR LINING
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED TOCLOSE HEAD FLASHINGALUMINIUM WINDOWJOINERY
25
25mm MIN. FROM OUTSIDE OF FRAMINGTO BACK OF WINDOW FLANGE
PROPRIETARY TAPE OVER HEADFLASHING SUPPLIED ANDINSTALLED BY FLASHMANCONTRACTOR
WALL UNDERLAY INSTALLEDAS PER E2/AS1
7.5/9.0mm REBATED SHEET
STOARMAT RENDER SYSTEM
20mm DRAINED CAVITY
STO uPVC CLIP-ON TRAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FLASHMAN HEAD FLASHING
FCS 878
2017
SCALE 1:2
FLASHMAN ALUMINIUM MITRESOAKER SUPPLIED BY FLASHMAN
INSTALLED BY BUILDER
H3.1 PACKER SUPPLIED ANDINSTALLED BY FLASHMAN
TIMBER FRAMINGTO NZS 3604
WALL UNDERLAY RETURNEDINTO OPENINGS & FLASHING
TAPE CONTINUOUS ALONGSILL MIN 100mm UP JAMBS &50mm ONTO FACE OF WALL
UNDERLAY
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX.
FLASHMAN BACK PLATE -SHOWN DASHED
FLASHMAN EXTRUDEDALU.SLIMLINE SILL
25mm MIN. FROM OUTSIDE FACEOF THE FRAMING LINE TO THEBACK OF WINDOW FLANGE
25
8
SUPPORT PACKER
14 GAUGE HOT DIPGALV.(316SS WHERE REQ.)S.T.H.C SCREWS @ 600mmCTRS. WITH 65mm MIN. FRAMEPENETRATION. SUPPLIED BYFLASHMAN
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATED FCSHEET
CAVITY BATTENS
STO uPVC STICK ONJOINERY CONNECTOR8mm MIN.STO uPVC CLIP ONFLASHING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FLASHMAN SILL FLASHING
FCS 879
2017
SCALE 1:2
CAVITY BATTENS
LINE OF FLASHMANSLIMLINE SILL
INTERNAL LINING
TIMBER FRAMINGTO NZS3604
FLASHING TAPE(100mm UP JAMBS)
H1.2 PACKER TOSUPPORT JOINERY
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX.
ALUMINIUMWINDOW JOINERY
25mm MIN. FROM OUTSIDEFACE OF FRAMING TOBACK OF WINDOW FLANGE
25
STOARMAT RENDERSYSTEM
WALL UNDERLAY INSTALLEDAS PER E2/AS1
7.5/9.0mm REBATED FCSHEET
FLASHMAN EXTRUDEDALUM.JAMB FLASHING
H3.1 PACKER SUPPLIEDAND INSTALLED BYFLASHMAN CONTRACTOR
STO uPVC STICK ONJOINERY CONNECTOR
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
FLASHMAN JAMB FLASHING
FCS 880
2017
SCALE 1:2
AIRSEAL OVER PEFROD GAP 7.5-8mm
APPROX
TIMBER LINTEL ASPER NZS 3604
INTERIOR LINING STO uPVC CLIP-ON FLASHING
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FORVERY HIGH AND EXTRAHIGH WIND ZONES
PROPRIETARY HOMERITPVC WINDOW JOINERY
PROPRIETARY ALUMINUMWINDOW HEAD FLASHING, 15°SLOPE AND 10mm COVER ATWINDOW HEAD
5
WALL UNDERLAY INSTALLEDAS PER E2/AS1
7.5/9.0mm REBATEDFC SHEET
STOARMAT RENDERSYSTEM
20mm DRAINED CAVITY
FLASHING TAPE ONTO WALLUNDERLAYuPVC VENT STRIP
1. IN EXTRA HIGH WIND ZONESINCREASE FLASHING COVER TO60mm AND USE A RIGID UNDERLAY
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HOMERIT PVC JOINERY - HEAD DETAIL
FCS 881
2017
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
WALL UNDERLAY RETURNEDINTO OPENINGS & FLASHING
TAPE CONTINUOUS ALONGSILL MIN 100mm UP JAMBS &50mm ONTO FACE OF WALL
UNDERLAY AS PER E2/AS1
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX.
INTERIOR LINING
JOINERY SUPPORT BARREQUIRE FOROPENINGS OVER 600mm
PROPRIETARY HOMERITPVC WINDOW JOINERY
MS SEALANT
STO uPVC SILL FLASHING
STOARMAT RENDERSYSTEM
7.5/9.0mm REBATED FCSHEET
CAVITY BATTENS
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HOMERIT PVC JOINERY - SILL DETAIL
FCS 882
2017
SCALE 1:2
INTERNAL LINING
TIMBER FRAMINGTO NZS3604
FLASHING TAPE ASPER E2/AS1
H1.2 PACKER TOSUPPORT JOINERY
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX.
PROPRIETARYHOMERIT PVCWINDOW JOINERY
MS SEALANT
LINE OF SILLFLASHING
LINE OF HEADFLASHING
STOARMAT RENDERSYSTEM
WALL UNDERLAY LAPPED & STAPLEDONTO INSIDE FRAME COVERED WITH
FLASHING TAPE AS PER E2/AS17.5/9.0mm
REBATED SHEETCAVITY BATTENS
STO uPVC JAMB FLASHING GLUEOR BED FLASHING IN PLACE
BEFORE RENDERING
The information contained on this page is based on our experience and research at the date of issue. The detail is for use by RegisteredArchitects, Licensed Designers or Chartered Engineers to assist in developing project details using Sto Systems. Stoanz Ltd reserve the right toalter or update information at any time without prior notice and it is the responsibility of the designer, project manager or Sto contractor to insurethey have and use the current Sto details and specifications on site.
STO/MONOTEK
STOARMAT RENDER SYSTEM
HOMERIT PVC JOINERY - JAMB DETAIL
FCS 883
2017