Innovative Aeration Systems since 1995
Presented by:Tom FrankelSystems, since 1995Director
*Reduce Fouling
*Reduce Maintenance
*Reduce Cleaning Frequency
*Reduce Replacement Cycle
*Reduce Permit Violations
*Reduce Cost
*Best Warranty, Guaranteed
5/11/2009 1
Let’s get started….
DID YOU KNOW….?DID YOU KNOW….?
90% of failures of a membrane diffused aeration system are caused by failed membranes?
5/11/2009 2
DID YOU KNOW….?DID YOU KNOW….?
In most cases, the cost of replacing membranes in a tank is higher than the cost of those membranes, when you consider hidden costs?
STEADILY DECLINING PERFORMANCE ENERGY $$LABOR & CLEANING OUT OF SERVICE
= NO INCOME!!PERFORMANCE = ENERGY $$
5/11/2009 3
DID YOU KNOW….?DID YOU KNOW….?
EPDM is a very durable material, but it is EPDM is a very durable material, but it is susceptible to fouling, which may include permanent swelling, shrinking, or crust?
CalciumCarbonate(lime)
CalciumSulfate(gypsum)
Dairy Products Animal Fat
Petroleum Vegetable OilsAlcohol
5/11/2009 4
DID YOU KNOW….?DID YOU KNOW….?
Plastic gas cans are made of polyethylene, which is not recommended for gasoline or diesel service.
Lab bottles that store aggressive solvents are also made of polyethylene which is not also made of polyethylene, which is not recommended for those solvents.
5/11/2009 5
DID YOU KNOW….?DID YOU KNOW….?
The first PTFE coated frying pan was developed in France by TEFAL in 1954?
5/11/2009 6
DID YOU KNOW….?DID YOU KNOW….?
SSI has patents and patents pending on PTFE coated membrane diffusers, and on fluorinated membrane diffusers.
Those diffusers have a track record in service since late 2004, and have outlasted plain EPDM membranes in aggressive applications by a 10:1 margin10:1 margin.
5/11/2009 7
DID YOU KNOW….?DID YOU KNOW….?
T t t #84395 d t d A il 30 Test report #84395 dated April 30, 2009 proves that SSI’s patent-pending surface fluorination reduces plasticizer loss in an aggressive hot acetone
l ti d t t d d EPDM solution compared to standard EPDM membranes by 25%.
Phoenix 91st Ave is retrofitting 2 basins i 2009 ith fEPDM f SSIin 2009 with fEPDM from SSI.
New Old Older Fossil
5/11/2009 8Not with fEPDM!!!
e O d O de
DID YOU KNOW….?DID YOU KNOW….?
In your contract with SSI, you are in the unique position to negotiate extended warranties with SSI, because of our technology.
5/11/2009 9
DID YOU KNOW….?DID YOU KNOW….?
Not all EPDM is created equal SSI uses Compression Not all EPDM is created equal. SSI uses Compression Molding and 700% elongation material. Most competitors are using injection molding and 500% elongation material, to save cost.
5/11/2009 10
SOME SSI FACES, ON SITE, AT WORK, AND WORLDWIDESOME SSI FACES, ON SITE, AT WORK, AND WORLDWIDEFOR OVER 14 YEARS:FOR OVER 14 YEARS:
5/11/2009 11
EXPERIENCE:BNRSBRMBRUASBCONVENTIONALEXTENDED AERATIONFIXED FILM
TECHNOLOGY SKILL SET:TECHNOLOGY SKILL SET:ACAD2007 2D + 3DBIOWIN SIMULATIONINVENTOR 3DINVENTOR 3DMATHCAD 13FLASH ANIMATIONPROPRIETARY SOFTWARE
JOBSITE EXPERIENCE
REFERENCES:TURNKEY SUPPLY BLOWER ROOM DESIGNPIPING LAYOUTSMULTISTAGE BLOWERSMULTISTAGE BLOWERSROOTS TYPE BLOWERS
CALCULATIONS:SOTEHEADLOSSBUYOANCY LOADINGBUBBLE ASCENT VELOCITYHEAT TRANSFERDO PROFILE ANALYSISDO PROFILE ANALYSISMINIMUM MIXINGLIFE CYCLE COST
CURRENT RESEARCHCURRENT RESEARCH
Ultra Fine Bubble Membranes under DevelopmentUltra Fine Bubble Membranes under Development
5/11/2009 14
PTFE MEMBRANES – Failure Mode? Not Yet
We observe that a biofilm layer does form on PTFEMembranes, though it takes a long time to form, and when it Does even in aggressive environments it can be removed Does, even in aggressive environments, it can be removed With a fingertip. The scale does not affect performance and Does not enter the slits. See below…
5/11/2009 15
Why PTFE??? – Don’t let this happen to you!
5/11/2009 16
PTFE FINE BUBBLE DIFFUSER MEMBRANESPTFE FINE BUBBLE DIFFUSER MEMBRANES
SSI’s PTFE ( Polytetrafluoroetyhylene) layered EPDM discand tube diffuser membranes combine the reliability of EPDM with outstanding anti fouling resistance of PTFEwith outstanding anti fouling resistance of PTFE.
Benefits of PTFE layer are:
• Resistance to fouling and calcium scaling• Resistance to fouling and calcium scaling• Extended life• Reduces cleaning 6-10 times compared to EPDM• Outstanding chemical resistance• Outstanding resistance to fats oils and greases• Outstanding resistance to fats, oils and greases• Outstanding resistance to hydrocarbons, fuels,
and solvents
“PTFE IS THE BEST THING TO HAPPEN TO“PTFE IS THE BEST THING TO HAPPEN TOFINE BUBBLE AERATION SYSTEMS”FINE BUBBLE AERATION SYSTEMS”
Dave Redmon, Eng.Dave Redmon, Eng.
5/11/2009 17
, g, g
SSI IS A TECHNOLOGY COMPANY
5/11/2009 18
SSI COMPRESSION MOLDS MOST MEMBRANESSSI COMPRESSION MOLDS MOST MEMBRANES
•SSI’s EPDM compound is specially formulated for wastewaterapplications providing:
•Even specific gravity thickness and tear resistance•Even specific gravity, thickness, and tear resistance
• Greater resistance to elongation and tearing (multidirectional tear resistance)
• Resistant to material property changes.
• High modulus for elasticity.
• Proper taper to reduce unit stress.
• High oxygen transfer efficiency.
• Extended service life
5/11/2009 19
COMPOUND DEVELOPMENTCOMPOUND DEVELOPMENTCOMPOUND DEVELOPMENTCOMPOUND DEVELOPMENT
Same slit pattern different compounds =
5/11/2009 20
Same slit pattern, different compounds = different bubble size & distribution
DISC MANUFACTURE
TESTING MEMBRANESTRENGTHSTRENGTH
DIFFUSER ASSEMBLY
5/11/2009 21
MEASURING BREAKPRESSURE FINE BUBBLES
AFD350
PATENTED QUICK CONNECT SADDLE MOUNTINGSYSTEM FOR 9” AND 12” DISCS
5/11/2009 22
DISC CONNECTIONS
5/11/2009 23
SNAPPY SADDLE™SNAPPY SADDLE™
• Each diffuser has a single seal on top of the headers and can be installed by 1 person rapidly
•Quick connection low headloss high SOTE •Quick connection – low headloss – high SOTE –compression molded tube membranes
5/11/2009 24
COARSE BUBBLE DIFFUSERS
The plastic SSI Coarse Cap and Stainless Wide Bandtypes are the most common coarse bubble diffusers.These are often used in digesters, sludge holdingtanks, and equalization basins.
5/11/2009 25
SSI PLASTIC PIPE FABRICATION
(Poughkeepsie, NY)
5/11/2009 26
SSI SS PIPE FABRICATIONSSI SS PIPE FABRICATION(Cincinnati, OH)
5/11/2009 27
WEB (.NET)+ LOCAL CALCULATION SOFTWARE
5/11/2009 28
WEB (.NET) BASED DRAFTING SOFTWARE
5/11/2009 29
WEB (.NET) BASED DRAFTING SOFTWARETypical Results
5/11/2009 30
BIOWIN SIMULATION CAPABILITY
Aeration 1Anoxic 1 Aeration 3Main Effluen
Influent0
P i Sl d
Anoxic 2
Primary Sludge
WAS
5/11/2009 31
INDEPENDENT NON-STEADY STATE TESTINGDetermination of SOTE of SSI SSI Diffusers per ASCEATC, SA Barcelona SpainRedmon Engineering, Milwaukee, USARedmon Engineering, Milwaukee, USA
5/11/2009 32
INDEPENDENT NON-STEADY STATE TESTING
5/11/2009 33
COMPETITIVE RESULTS
5/11/2009 34
INDEPENDENT STEADY STATE TESTINGDetermination of α in a Virginia, USA BNRRedmon Engineering, Milwaukee, USA
5/11/2009 35
NEW VS. OLD SSI MEMBRANE PERFORMANCE
5/11/2009 36
SSI PLASTIC PARTS SUPPLIER QC MONITORING & PROTOCOL
5/11/2009 37
SSI MEMBRANE SUPPLIER QC MONITORING & PROTOCOL
5/11/2009 38
LARGE PROJECT – MIL 105E TEST PROTOCOL
5/11/2009 39
IN-HOUSE TESTING & REPORTS
5/11/2009 40
IN-HOUSE TESTING & REPORTS
5/11/2009 41
IN-HOUSE TESTING & REPORTS
5/11/2009 42
SUPPORTS
5/11/2009 43
EXPANSION JOINTSEXPANSION JOINTS
5/11/2009 44
REPLACEMENT MEMBRANES
5/11/2009 45
SYSTEMSSYSTEMS
“We are extremely pleased with our latest purchase from you. Our wasted biomass is now kept fresh and free from release of NH3 and Ortho-P during storage. We will be looking at replacing all membranes in the Ford Road Aeration Basins in 2007
5/11/2009 46
Aeration Basins in 2007. I would like to get a price from you soon. Have a happy holidays! Jason Tincu, Xenia WWTP Supervisor”
SYSTEMS
“After evaluation, EA decided to proceed withSSI's 12-inch diameter fine bubble diffusers. Due to the size and efficiencies of the SSI diffuser,
5/11/2009 47
efficiencies of the SSI diffuser,the number of diffusers required for the project is significantly less than the other Manufacturers. We highly recommend SSI and we would like to work with them again on our next project.”Chuck Place, P.G., EA Engineering Inc.
SYSTEMSSYSTEMS
“SSI designs complete aeration systems including calculations of SOTE, temperature, with drawings and all complimentary information for aerobic reactors. Their technical help is the best in the business. “
5/11/2009 48
Marcelo Mascheroni Lay, Sanitary Engineer, Ecoplan Uruguay (former SanitaireTM
SYSTEMS
“In 2003 our company El Concorde purchased 6000 sets AFT1000 diffuser from SSI to be used on a wastewater treatment project in Iraq under the Program Oil for Food with the UN. I evaluated a number of American and European companies and finally selected SSI due to a
5/11/2009 49
robust product and good communication.”Ghassan Ayyubi – El Concorde Ltd, Jordan
SYSTEMSSYSTEMS
5/11/2009 50
SYSTEMS
“We have had the Stamford disc diffusers installed inour two 450,000 gallon sludge holding basins for nearlyfive years and we have never had a problem with them.We also see adequate mixing and desired performance.The basins are inspected periodically and we have noth d t l f th d l t d t ”
5/11/2009 51
had to replace any of the modules to date.”Jerry Basham - Chief Operator North WWTP,Henderson Water Utility, Henderson, KY
SYSTEMS
“I called Pierre Filion today. He is just back from vacation. He said that he checked his aeration system this morning and y geverything seems OK. The bubbles are still nice, so he does not expect problems for sometimes. The Teflon membranes were installed Dec. 04. One month earlier, he had installed (other brand) EPDM membranes in the other reactor (Nov. 1) and the bubble size is not so good and he is expecting problems soon.”
5/11/2009 52
Gaetan Desjardins, Premier Tech Environment – QC, Canada
SYSTEMSSYSTEMS
“We came across the SSI diffusers and first tried them in the summer of 2005. It was probably the best decision we have made in our wastewater treatment plant since it started processing water. Not wastewater treatment plant since it started processing water. Not only can we afford to replace the old diffusers, the new SSI seem to be more durable than the old ones and don't require as much maintenance. We also see that they do not plug up or scale up as bad as the old diffusers. Our current blowers could not be happier as well as myself. We have been thoroughly satisfied with the SSI diffusers
5/11/2009 53
from DGJ Gongol and Associates and would recommend these diffusers to everyone. Thank you for such a good and reliable product. You have definitely made life easier for all of ushere at SCA Tissue. “, Paul Johnson – SCA Tissue, Menasha, WI
SYSTEMS
“We hereby confirm that TEFLON membranes have been working since beginning of February without clogging problems. Before we had to clean the (NoponTM) EPDM membranes every 3-4 weeks!”
Ringkøbing Renseanlæg, Denmark
5/11/2009 54Gunnar Larsen
SYSTEMS
“The diffusers AFD-350 are working very well in Podolsk. At present we are installation some diffusers in Protvino and Redkino. We have received ≈ 2 thousand pieces in
5/11/2009 55
Solnechnogorsk. “
Robert Agronanonik, BIFAR, Russia
SYSTEMS
“Pumpteknik have delivered 800 pcs of SSI membranes to Flygt SanitaireTM 9” discs. Today we see a much better oxygen transfer as before surely caused by the better materiel and perforation. We can warmly recommend this product!”
5/11/2009 56
- Nilks Bak Andersen, Teknisk Chef, A/S Saeby Fiske-Industri Denmark
SYSTEMS
“We’ve have had very good luck with the membranes we purchased from your company last year.”
5/11/2009 57
-Richard Rader, Sara Lee Bakery, Traverse, MI USA
SYSTEMSSYSTEMS
5/11/2009 58
SYSTEMSSYSTEMS
“Al Salam Alaikum,Reference to your letter dated 13/1/1426 H. requesting ouropinion about the Air diffusers supplied by SSI to our projects.We would like to advise you that these diffusers have been
d b d th i lit d t d did t ti
5/11/2009 59
approved based on their quality product and we did not noticeany technical problems.”
-Yazeed Yehya Al Ayed, Ministry of Water, KSA
SYSTEMSSYSTEMS
“SSI has been a pleasure to work with before, during and after the sale and installation.They hopped through hoops to meet tight delivery schedules and they stayed in touch toinsure the installed-system integrity was as promised and expected. Its nice to knowthat there are firms out there that deliver quality product, in a timely manner andrecognize that there is more to a successful project than just the bottom line their
5/11/2009 60
than just the bottom line... theirservice was exemplary.”
Don Mathsen, Grand Forks ND WWTP
SYSTEMSSYSTEMS
“Thank you for your excellent support at such short notice for the successful completion of the above project using SSI Disc Diffuser successful completion of the above project using SSI Disc Diffuser System. I am pleased to inform you thatthe client is very happy especially now that their power consumption has been greatly reduced and is now consuming about 30% of its original cost.The plant is now meeting all the necessary standards as required by the department of
5/11/2009 61
Environment. “
-Debbie Chee, Tekno Suling SDN Bhd (former NoponTM customer)
SYSTEMSSYSTEMS
“I have also been in contact with the Supervising Engineer for the owner of our Activated Sludge WWTP in the Dominican Republic. He confirms g pthat the aeration system continues to perform admirably - a claim he admits he cannot make for many of the other water purification systems. These reports confirm my confidence in the design, engineering and product support which I have come to rely on from SSI. The professional abilities of you and your staff help to relieve of the t h i l I fi d t b t i l t d ith f
5/11/2009 62
technical concerns I find to be so typical today with many of our systems suppliers.”
David Burgess, Dir. Of Engineering, Krofta Technologies, Inc.
SYSTEMSSYSTEMS
“We certify that we have bought along the last five (now 10) years, fine bubble disc diffusers and tubular diffusers from SSI, which have been installed in more than 30 of our W t t t t t l t j t h f t d Wastewater treatment plants projects we have manufactured within this time in different countries.In most of these projects we have received not only the sales assistance but also technical support in the designing when it was required. All the projects we have installed the 9", 12" and tubular SSI diffusers operate successfully complying the
5/11/2009 63
and tubular SSI diffusers operate successfully complying the parameters they were designed for, will no operational andquality problems in diffusers and membranes”
Andres Silva, Proton USA Corp., Miami, FL USA
SSI vs Nopon TM
5/11/2009 64
Dear Tom.The plant has 3 parallel tanks with first 2,100 pcs Nopon TM 215 then later 2,100 Nopon TM on top of them. The
costumer has had problems with leak between the old and new one. Nopon TM have changed the system several times so the plant decided to use AFD 350 with saddl for pipe ø90. They are very surprised the SSI’s disc is as
efficient as seen on the Graph from 06-11-2004. Visual you can see by photos921 that Nopon TM in one place have pop up and photo 923 at sidewall you see no bubbles. On photo 924 you
have a beautiful view of AFD 350’s efficiency and on photo 922 you can see the overwhelming amount of bubbles.After having installed 700 pcs AFD 350, we shall deliver 700 more this year and 700 next year. Dan ChristensenPumpteknik ApSHans Rostgårdsvej 4DK-3050 HumlebækTlf : 0045 49 16 16 76 Fax: 49 16 16 96Tlf.: 0045 49 16 16 76 - Fax: 49 16 16 96
5/11/2009 65
The following graph depicts the performance of two tanks in Denmark. Tank 1 has Nopon TM 300 size diffusers. In Tank 2, SSI replaced the Nopon TM membranes with SSI 12” retrofit membranes. The two tanks ran side by side. Notice how the valve to the air supply in the SSI tank is mostly closed, and the valve to the air supply in the y , pp yNopon TM tank is mostly open, yet the DO is higher in the SSI tank, in spite of receiving much less air.
5/11/2009 66
Hi Tom.Here the first result of changing from Nopon TM 215 to AFD 350/PTFE. Saving ca 16%. But we have to adjust the plant concerning the pressure, so I’ll be back. I would like to end about 25%.
Ad1)
Med venlig hilsen/With best regards
Pumpteknik ApS/SSI North EuropeDan Christensen
www pumpteknik dkwww.pumpteknik.dkTlf.: ++45 49161676, Fax.: ++45 49161696Mobil: ++45 31655158 - e-mail mobil: [email protected] member: Pumpteknik
Totalt elforbrug
Elforbrug til beluftning
Procent beluft ud af
total IndløbsflowElforbrug total
pr. m3 vand
Elforbrugbeluftning pr. m3
vandelforbrug beluftning total Indløbsflow pr. m3 vand vand
kwh kWh % m3 kWh(total)/m3kWh(beluftning)/m
3maj-07 49958,00 12238,00 24% 201744,00 0,25 0,060661036jan-08 66713,00 12719,00 19% 232016,00 0,29 0,054819495feb-08 58877,00 11429,00 19% 224598,00 0,26 0,050886473
Besparelse 16%Besparelse 16%
5/11/2009 67
ARS TANK
5/11/2009 68
5/11/2009 69
5/11/2009 70
THANK YOU.THANK YOU.WE LOOK FORWARDWE LOOK FORWARD
TO WORKING WITH YOU.TO WORKING WITH YOU.
5/11/2009 71