Section 10
Commercial Reverse Osmosis Systemsand Accessories
249
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
R13 Compact Wall Mount RO
250
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries R4X40 Series Whole House RO
Three models for flow rates up to 6,600 GPD
Standard features• Powder coated steel frame• Inlet solenoid valve• 20” prefilter• Prefilter pressure gauge• Multistage centrifugal pump• Low-pressure protection withmicroprocessor auto reset
• 2 1/2” liquid filled pump pressure gauge• Stainless steel pressure vessel(s)• Product flow meter• Reject flow meter• Concentrate needle valve• Non metallic recycle needle valve• Feed water and product water TDS monitor
• Whole house• Boiler feed water• Humidifiers
• Greenhouses• Process Water• Electronics
Applications
Specifications
Membrane Size 4” x 40”Average membrane rejection 98 %Feed Water Connection 3/4" NPTFPrefilter 2.5” x 20”Product Water Connection 5/8" tubing ODReject Water Connection 5/8" tubing ODFeed Water Pressure (minimum) 10 psiElectrical Requirement * 120 VAC 60 Hz
Options
Part Number Description
R2353-SD Product float switchR2288-165 165 gal tank whole house option*R2288 300 gal tank whole house option*R2288-500 500 gal tank whole house option*
*Includes atmospheric storage tank, product float switch, andrepressure pump with built in controls.
Notes: Maximum production based on a feed water of 77°F, SDI < 1, 1000 ppm TDS, and pH 7. Individual membrane productivity may vary(± 15%). May be operated on other feed waters with reduced capacity. Percent Rejection is based on membrane manufactures specifications;overall system percent rejection may be less. *R4X40-3 is available only in 230-volt single phase.
ModelsR4X40-1 R4X40-2 R4X40-3
Maximum Productivity (gallons per day) 2200 4400 6600Recovery (user adjustable) 15 - 75 % 25 –75% 32 - 75 %Number Of Membranes 1 2 3Feed Water Required (maximum) 10gpm 12 gpm 14 gpmDrain Required (maximum) 10gpm 12 gpm 14 gpmMotor Horse Power 3/4 1 1 1/2Electrical Requirement* 15 amps 20 amps 25 ampsDimensions W x D x H 20 x 20 x 50 20 x 20 x 50 20 x 26 x 50Shipping Weight (estimated lbs) 120 150 180
Model: R4X40-1
Note: For indoor installation only.
251
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
R12 Series Wall-Mounted RO Systems
Compact, wall-mounted systems
Four models for flow rates to 1200 GPD.
Standard features (package #1)
• Stainless steel frame• Automatic inlet valve• Pre-filter housing and cartridge, 10"• Procon pump (brass)• 1/2 HP motor• Liquid filled pump pressure gauge (2-1/2")• Stainless steel pressure vessels• Needle valve for concentrate line• Needle valve for recycle line• Check valve for product water (stainless steel)• Product pressure switch with Auto/Off• Low-pressure shut-off with automatic restart
Additional features included in package #2
• Pre-filter pressure gauges• Product water flow meter• Reject water flow meter
Additional features included in package #3
• Automatic fast flush for concentrate
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperatureconversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro® FPMB5-978 melt blown cartridge.Systems are designed for use with municipal and well water.
R12-1200-2 system with optional legs
*Includes 300 gallon tank, product water float switch and repressuriza-tion pump with built-in controls.
252
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries R14 Series Wall-Mounted RO Systems
Compact, wall-mounted systems
Three models for flow rates to 5400 GPD,available with brass and stainless steel fittings.Fully assembled and ready for installation.
Standard features
• Stainless steel frame• Stainless steel pressure vessels• Pre-filter housing and cartridge, 10" Full-Flow• Webtrol® multi-stage centrifugal pump• Automatic inlet valve• Low-pressure shut-off with automatic restart• Tank level input• Pretreatment interlock input• Adjustable recycle line• Pre-filter pressure gauges• Pump discharge pressure gauge (liquid filled)• Flow meter for product water• Flow meter for reject water• Check valve for product water• Sample valve for product water• On / off switch
R14-03-BWM System
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperatureconversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro® FPMB-BB5-10 melt blown cartridge.Systems are designed for use with municipal and well water.
253
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
R14 Series Floor Model RO Systems
Top quality, attractively priced,fully assembled RO systems
Five models for flow rates to 10,800 GPD. Selectthe features you want to meet your requirements!
Standard features (package #1)
• Powder coated steel frame• Stainless steel pressure vessels• Pre-filter housing and cartridge (20" Full-Flow)• Webtrol® heavy-duty multi-stage centrifugal pump• Automatic inlet valve• Low-pressure shut-off with automatic restart• Tank level input• Pretreatment interlock input• Adjustable recycle line• Pre-filter pressure gauges• Pump discharge pressure gauge (liquid filled)• Flow meter for product water• Flow meter for reject water• Flow meter for recycle water• Check valve for product water• On / off switch
Additional features included with package #2
• CI-1000 electronic controller with productwater conductivity meter and alarm output
• Programmable concentrate auto flush
R14-06-1131100 System
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperatureconversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro® FPMB-BB5-20 melt blown cartridge.Systems are designed for use with municipal and well water.
254
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries R24 Series Commercial RO Systems
Three models and two design options for flow rates up to 15 GPM.
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperatureconversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is 20” Full-Flow plastic housing and Flow-Pro®
FPMB-BB5-20 melt blown filter cartridge. Systems are designed for use with municipal and well water
• Powder coated steel frame• FRP multi-port pressure vessels• Pre-filter housing and cartridge (20” B-B)• Webtrol® multi-stage centrifugal pump• Automatic inlet valve• Low-pressure shut-off with auto restart• Tank level input• Pretreatment interlock input
• Adjustable recycle line• Pre-filter pressure gauges• Pump discharge pressure gauge• Flow meter for product water• Flow meter for reject water• Flow meter for recycle water• Check valve for product water• Sample valves for product water• On / off switch
Standard features (package #1)
Additional features included with package #2
• CI-1000 electronic controller withproduct water conductivity meter andalarm output
• Programmable concentrate auto flush
255
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
R44 Series Commercial RO SystemsThree models and two design options for flow rates up to 30 GPM.
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperatureconversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Max® FM4X3 filter housing, constructedusing 316 stainless steel and 2" MNPT pipe fittings and Flow-Pro® FPMB5-30 melt blown filter cartridges. Systems are designed for use withmunicipal and well water.
• Powder coated steel frame• FRP multi-port pressure vessels• Stainless steel pre-filter and cartridges• Webtrol® multi-stage centrifugal pump• Automatic inlet valve• Low-pressure shut-off with auto restart• Tank level input• Pretreatment interlock input
• Adjustable recycle line• Pre-filter pressure gauges• Pump discharge pressure gauge• Flow meter for product water• Flow meter for reject water• Flow meter for recycle water• Check valve for product water• Sample valves for product water• On / off switch
Standard features (package #1)
• CI-1000 electronic controller with product waterconductivity meter and alarm output
• Programmable concentrate auto flush
Additional features included with package #2
256
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries R48 Series Commercial RO Systems
Four models for flow rates up to 100 GPM.
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperatureconversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Max® FM7x4 filter housing, constructedusing 316 stainless steel and 2" MNPT pipe fittings and Flow-Pro® FPMB5-40 melt blown filter cartridges. Systems are designed for use withmunicipal and well water.
• Powder coated steel frame• FRP multi-port pressure vessels• Stainless steel pre-filter and cartridges• Webtrol® multi-stage centrifugal pump• Automatic inlet valve• Low-pressure shut-off with auto restart• Tank level input• Pretreatment interlock input
` • Adjustable recycle line• Pre-filter pressure gauges• Pump discharge pressure gauge• Flow meter for product water• Flow meter for reject water• Flow meter for recycle water• Check valve for product water• Sample valves for product water• On / off switch
Standard features
Additional features included R48 systems
• CI-2000 electronic controller with feedand product water conductivity meter withpercent rejection
• Programmable concentrate auto flush
R48-20-3131100
198"x42"x72"
198"x42"x72"
198"x42"x72"
198"x42"x72"
257
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
258
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries Commercial RO Membranes
Top quality membranes for commercial reverse osmosis systems.
Watts® commercial membranesPart Number Application O.D. Length Capacity No. Per
(GPD) Case
W-2521-TW Tap water 2-1/2" 21" 300 1W-2540-TW Tap water 2-1/2" 40" 800 1W-4021-TW Tap water 4" 21" 1,050 1W-4040-TW Tap water 4" 40" 2,200 1W-4040-BW Brackish water 4" 40" 2,200 1
Note:Watts commercial membranes are packaged in preservatives. Keep in cool environment if stored for prolonged periods of time.
Filmtec® by Dow® commercial membranes for tap waterPart Number Application O.D. Length Capacity (GPD) No. Per Case
TW30-2514 Tap water 2-1/2" 14" 170 1TW30-2521 Tap water 2-1/2" 21" 300 1TW30-2540 Tap water 2-1/2" 40" 660 1TW30-4014 Tap water 4" 14" 480 1TW30-4021 Tap water 4" 21" 900 1TW30-4040 Tap water 4" 40" 2,200 1
Note: Specifications are based on 225 psi pressure and 77°F temperature.
Commercial membranes for brackish waterPart Number Application O.D. Length Capacity (GPD) No. Per Case
BW30-2540 Brackish water 2-1/2" 40" 660 1BW30-4040 Brackish water 4" 40" 2,200 1BW30-400 Brackish water 8" 40" 10,500 1
Note: Brackish water membrane specifications are based on 225 psi pressure and 77°F temperature.
Watts membrane specificationsData W-2521-TW W-2540-TW W-4021-TW W-4040-TW W-4040-BW
Membrane type TFC TFC TFC TFC TFCMaterial Polyamide Polyamide Polyamide Polyamide PolyamideCharge Negative Negative Negative Negative NegativeConfiguration Spiral-wound Spiral-wound Sprial-wound Spiral-wound Sprial-woundSalt rejection 99.5% 99.5% 99.5% 99.5% 99.5%Max. operating temp. 113°F / 45°C 113°F / 45°C 113°F / 45°C 113°F / 45°C 113°F / 45°CMax. operating pressure 400 psi 400 psi 400 psi 400 psi 600 psiMaximum turbidity (NTU) <1 <1 <1 <1 <1Max. SDI <5 <5 <5 <5 <5pH range (cleaning) 2-11 2-11 2-11 2-11 2-11Flux (GPD) 300 800 1,050 2,200 2,200
Note: Tap water membrane specifications are based on 225 psi pressure and 77°F temperature.
Filmtec® by Dow® commercial membranes for sea water
Part Number Application O.D. Length Capacity (GPD) No. Per Case
SW30-2514 Sea water 2-1/2" 14" 100 1SW30-2521 Sea water 2-1/2" 21" 200 1SW30-2540 Sea water 2-1/2" 40" 540 1SW30-4021 Sea water 4" 21" 600 1SW30-4040 Sea water 4" 40" 1,500 1SW30-8040 Sea water 8" 40" 6,000 1
259
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
Filmtec® Commercial Membranes
Tapwater elements
Brackish water elements
TGI Part Number Filmtec Number GPD Size Case Qty
MM-2026-220 TW30-2026 220 GPD 2"X26" 1MM-2514-170 TW30-2514 170 GPD 2.5"X14" 1MM-2521-300 TW30-2521 300 GPD@225PSI 2.5"X21" 1MM-2540-650 TW30-2540 650 GPD@225PSI 2.5"X40" 1MM-4014-480 TW30-4014 480 GPD 4"X14" 1MM-4021-900 TW30-4021 900 GPD 4"X21" 1MM-4040-2200 TW30-4040 2200 GPD 4"X40" 1MM-2521-XLE XLE-2521 400 GPD 2.5"X21" 1MM-2540-XLE XLE-2540 770 GPD 2.5"X40" 1MM-4021-XLE XLE-4021 1000 GPD 4"X21" 1MM-4040-XLE XLE-4040 2400 GPD 4"X40" 1
TGI Part Number Filmtec Number GPD Size Case Qty
MM-BW30-2540 BW30-2540 650 GPD 2.5"X40" 1MM-BW30-4040LE BW30LE-4040 2800 GPD 4"X40" 1MM-BW30-4040 BW30-4040 2200 GPD 4"X40" 1MM-BW30-365 BW30-365 9500 GPD 8"X40" 1MM-BW30-400 BW30-400 10500 GPD 8"X40 1MM-BW30LE-440 BW30LE-440 11500 GPD 8"X40" 1
TW30-4040#MM-4040-2200
XLE-2540#MM-2540-650
XLE-4021#MM-4021-900
TW3O-2521#MM-2521-300
TW3O-2514NumberMM-2514-170
Membranecut-a-wayfor quality
you can see!
260
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries Commercial Membrane Housings
Fiberglass membrane housings
Part Number Diameter Length Port PSI No. / Case
R9662-1C5C7C 4 80 See Drawing 300 1
R9662-1C6A 4 80 See Drawing 300 1
R9662-2C3C7C 4 80 See Drawing 300 1
R9662-3C5C 4 80 See Drawing 300 1
R9664-1C2A5C 4 160 See Drawing 300 1
R9664-2A5C7C 4 160 See Drawing 300 1
R9664-2A7C 4 160 See Drawing 300 1
R9664-3C5C7C8C 4 160 See Drawing 300 1
R9668-1E2D5E 8 160 See Drawing 300 1
R9668-2E3E7E 8 160 See Drawing 300 1
R9688-3E5E6E7E 8 160 See Drawing 300 1
R9668-3E5E7E 8 160 See Drawing 300 1
Stainless steel membrane housings
Part Number Material Diameter Length Port PSI No. / Case
R9677-SV2514.1 304 SS 2.5 14 1/2” Side X 3/8” End 300 1
R9677-SV2521.1 304 SS 2.5 21 ½” Side X 3/8” End 300 1
R9677-SV2540.1 304 SS 2.5 40 ½” Side X 3/8” End 300 1
R9677-SV4040.1 316 SS 4 40 ¾” Side X ½” End 300 1
R96-PV-4040-OS 304 SS 4 40 ¾” Side X 3/8” End 300 1
2.5" stainless steel membrane housing
Side port sizes
A = 3/4" FNPTC = 1" VictaulicD = 1.5" VictaulicE = 2" Victaulic
Note:Use this diagram and the port sizingchart at left to locate port locationsand sizes, by referring to the productcodes listed above.
4" Fiberglass 8" Fiberglass Stainless Steel
261
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
RO Pumps & Aquatec Pump Accessories
Procon® RO PumpsPart Number Series Type Material Flow Connector No. Per CasePU-112A015 2 Clamp on Brass 15 3/8" 1PU102A-35 2 Clamp on Brass 35 3/8" 1PU-112A-50 2 Clamp on Brass 50 3/8" 1PU-102A080F11XX 2 Clamp on Brass 80 3/8" 1PU-102A100F11XX 2 Clamp on Brass 100 3/8" 1PU-102A125F11XX 2 Clamp on Brass 125 3/8" 1PU-102A 2 Clamp on Brass 140 3/8" 1PU-112A140F11XX 3 Clamp on Stainless Steel 140 3/8" 1PU-103A100F31XX 3 Clamp on Stainless Steel 100 3/8" 1PU-103A125F31XX 3 Clamp on Stainless Steel 125 3/8" 1PU-104B190F11XX 4 Clamp on Brass 190 1/2" 1PU-114B190F11AA 4 Clamp on Brass 190 1/2" 1PU-114B240F31XX 4 Clamp on Brass 240 1/2" 1PU-114E240F31XX 4 Bolt on Brass 240 1/2" 1PU-105B190F31XX 5 Clamp on Stainless Steel 190 1/2" 1PU-105215F31XX 5 Bolt on Stainless Steel 215 1/2" 1PU-112A-CL Pump clamp (#1113)PU-112AO-1/3 GE motor (#H450) 1/3 HP, 230VPU-112A-MO12 GE motor (#H684) 1/2 HP, 115V / 230V
Aquatec® booster pump accessoriesPart Number Description No. Per CasePU-6000ESO Electric Shutoff Valve(ESO)for CDP 6800 Pump 24VAC 1PU-8800ESO-38 (98A1004N) Electric Shut Off Valve (ESO) 3/8"NPT 24VAC 1PU-6000LPS Aquatec Low Pressure Switch for CDP-6800 1PU-6000TSO (PSW240-00) Aquatec Tank Shut Off Valve for CDP-6800 1/4"JG 1PU-6000TSO38 (PSW340)Aquatec Tank Shut Off Valve 3/8"Jg 40PSI 1PU-6000TSO3860 (PSW360)Aquatec TSO 3/8"JG With 60 PSI Shut Off 1PU-8010TSO (94-090-01)Shur Flo Tank Switch W/Wire 1/4"JG Fittings 1PU-6800AFR/300 (AFR603)Aquatec Auto Flush Timer 300ML/Min. 1PU-6800AFR/400 (AFR604)Auqatec Auto Flush Timer 400ML/Min. 1PU-6800AFR/500 (AFR605)Aquatec Auto Flush Timer 500ML/Min. 1PU-6800AFR (ARF608)Aquatec Auto Flush Timer 800ML/Min. 1PU-TLC-DC900 (TLC-DC900)Tank Level Control Switch Valve DC 1PU-TLC-WIRE (21-075-01)TLC Wire Red, Green, Black 1
PU-WIRE-LPP (SPT03) LPP Wire Hardness 6" Tee Male/Female Connector2 White Connectors and 2 Plugs 1
PU-WIRE PumpWire for ESO Branch Tee Connector 3 White Connectors 1PU-WIRE/2M Pump Transformer "T" Connector W/2 Male Branches 1
Aquatec® pump repair kitsPart Number Description No. Per CasePU-550UHA (UHA-4-1F12J526)Upper Housing Assembly for PU-550 1PU-550LHA (LHA-4-1F12J526)Lower Housing Assembly for PU-550 1PU-6800LHA Lower Housing Assembly (#5-7) for 6800 Pump 1PU-6800UHA Upper Housing Assembly (#8-12) for 6800 Pump 1PU-6800VHA Valve Housing Assembly (#13-23) for 6800 Pump 1PU-8800DAI Lower Housing Assembly for 8800 Pump 1PU-88HEAD (88-11)8800 Pump Head Assembly 1
262
Co
mm
erci
alR
ever
seO
smo
sis
Sys
tem
sA
nd
Acc
esso
ries Blue-White® Flowmeters
Standard flowmeters for liquid with 316 ss guide rods
Part No. BW Part No. Series GPM Connection Adapter Material Float Material
R5126 F-40375LN-6 F-400N 0.1 to 1.0 3/8” Polypropylene PVC
R5127 F-40375LN-8 F-400N 0.1 to 1.0 1/2” Polypropylene PVC
R5129 F-40376LN-8 F-400N 0.2 to 2.0 1/2” Polypropylene 316 SS
R5131 F-40377LN-8 F-400N 0.3 to 3.0 1/2” Polypropylene 316 SS
R5138 F-40500LN-8 F-400N 0.5 to 5.0 1/2” Polypropylene 316 SS
R5139 F-40750LN-12 F-410N 1 to 10 3/4” Polypropylene 316 SS
R5140 F-40750LN-16 F-410N 1 to 10 1” Polypropylene 316 SS
R5141 F-41017LN-12 F-410N 1 to 17 3/4” Polypropylene 316 SS
R5142 F-41017LN-16 F-410N 1 to 17 1” Polypropylene 316 SS
R5143 F-41000LN-12 F-410N 2 to 20 3/4” Polypropylene 316 SS
R5144 F-41000LN-16 F-410N 2 to 20 1” Polypropylene 316 SS
R5150 F-44250LH-8 F-440 .025 to .250 1/2” Polysulfone PVC
R5152 F-44375LH-8 F-440 0.1 to 1.0 1/2” Polysulfone 316 SS
R5153 F-44376LH-6 F-440 0.2 to 2.0 3/8” Polysulfone 316 SS
R5154 F-44376LH-8 F-440 0.2 to 2.0 1/2” Polysulfone 316 SS
R5155 F-44500LH-6 F-440 0.5 to 5.0 3/8” Polysulfone 316 SS
R5156 F-44500LH-8 F-440 0.5 to 5.0 1/2” Polysulfone 316 SS
R5157 F-44750LH-12 F-440 1.0 to 10.0 3/4” Polysulfone 316 SS
R5395 F-451001LHN F-451 1.0 to 10 1” Polysulfone 316 SS
R5396 F-451002LHN F-451 2.0 to 20 1” Polysulfone 316 SS
R5397 F-451003LHN F-451 3.0 to 30 1” Polysulfone 316 SS
R5398 F-451004LHN F-451 4.0 to 40 1” Polysulfone 316 SS
R5406 F-452020LHN F-452N 2 to 20 2" FNPT Polysulfone Teflon
R5408 F-452060LHN F-452N 6 to 60 2" FNPT Polysulfone 316 SS
R5409 F-452080LHN F-452N 8 to 80 2" FNPT Polysulfone 316 SS
R5410 F-452100LHN F-452N 6 to 100 2" FNPT Polysulfone 316 SS
R5411 F-452130LHN F-452N 20 to 130 2" FNPT Polysulfone 316 SS
F-400 Series F-440 Series F-410N Series F-410N Series F-452 Series
263
Co
mm
ercialReverse
Osm
osis
System
sA
nd
Accesso
ries
Accessories for Commercial RO SystemsLiquid level controls, pressure switches & metal pressure tanks.
Liquid level controls
Float switch used with atmospheric storage tanksto shut-off system when tank is full.
Part Number Description
L75222 Control with single stage suction and 1/2" NPT PP fittings.
Pressure switch
Used with bladder pressure tanksto shut-off system with tank is full.
Part Number Description
U217-2E Switch pre-set 30-60 psi with 1/4" NPT fittings.
Important:Install level control so the float will hingeupward (as shown). Not downward.
264