DESIGN: STANDARDS:Twisted pair cable IEC 60092-3, design
1. Conductor- stranded copper conductor IEC 60228, class 2
2. Insulation- XLPE plastic IEC 60092-351
3. Bedding- filler tape
4. Armour- drain wire (in all sizes)- copper wire braid, coverage > 94% IEC 60092-350
5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request
250V
CAB
LES
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Armoured instrumentation andcommunication cable 250VRFE-HF
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 250VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical data 0,75mm2
Loop resistanceof pair / +20°C 52ohm/kmPair capacitance / 800Hz 50nF/kmLoop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Electrical data 1,5mm2
Loop resistanceof pair / +20°C: 24,4ohm/kmPair capacitance / 800Hz 60nF/kmLoop inductance 0,7mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
16
�
�� � �
250V CABLES
RFE-HF 250VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm1x2x0,75 8,0 105 501x4x0,75 9,5 140 602x2x0,75 12,5 175 754x2x0,75 14,5 245 907x2x0,75 17,5 375 1058x2x0,75 18,5 410 11510x2x0,75 21,5 500 13012x2x0,75 22,5 555 13514x2x0,75 24,0 630 14519x2x0,75 27,5 800 16524x2x0,75 30,5 960 1851x2x1,5 10,0 130 601x4x1,5 11,0 180 702x2x1,5 14,5 230 904x2x1,5 16,5 330 1007x2x1,5 20,5 530 1258x2x1,5 21,5 590 13010x2x1,5 24,5 710 15012x2x1,5 26,0 815 16014x2x1,5 27,5 915 16519x2x1,5 32,0 1190 195
17
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The four core cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue
DESIGN: STANDARDS:Twisted pair cable IEC 60092-3, design1. Conductor
- stranded copper conductor IEC 60228, class 22. Insulation
- XLPE plastic IEC 60092-3513. Individual screen
- plastic coated aluminium tape and a ground conductor
4. Bedding- filler tape
5. Armour- drain wire (in all sizes)
- copper wire braid, coverage > 94% IEC 60092-3506. Sheath
- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request
250V
CAB
LES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Armoured and pair screened instrumentation and communicationcable 250V
RFE-HF (i)
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 250VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical data 0,75mm2
Loop resistanceof pair / +20°C 52ohm/kmPair capacitance / 800Hz 70nF/kmLoop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Electrical data 1,5mm2
Loop resistanceof pair / +20°C: 24,4ohm/kmPair capacitance / 800Hz 90n F/kmLoop inductance 0,7mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature, standards,production month, manufacturer's name and meter marking printed on the sheath
18
���� �
�
250V CABLES
RFE-HF (i) 250VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm2x2x0,75 13,0 190 804x2x0,75 15,0 275 907x2x0,75 18,0 435 1108x2x0,75 19,0 480 11510x2x0,75 22,0 585 13512x2x0,75 23,0 665 14014x2x0,75 24,5 750 15019x2x0,75 28,0 955 17024x2x0,75 31,0 1160 1902x2x1,5 15,0 260 904x2x1,5 18,0 390 1107x2x1,5 21,5 635 1308x2x1,5 23,0 710 14010x2x1,5 26,0 865 16012x2x1,5 27,0 1000 16514x2x1,5 29,5 1130 18019x2x1,5 33,5 1480 205
19
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Kvaerner Masa-Yards HKI
DESIGN: STANDARDS:Twisted pair cable IEC 60092-3, design
1. Conductor- stranded copper conductor IEC 60228, class 2
2. Insulation- XLPE plastic IEC 60092-351
3. Separator- separator tape
4. Screen- drain wire (in all sizes)- aluminium polyester tape IEC 60092-350 coverage 100%
5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request
250V
CAB
LES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Screened instrumentationand communication cable 250VRFA-HF
Application: For fixed installation in all areas and on open deck in ships Especially when lightweight cables are needed
Main characteristics
Rated voltage 250V
Maximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series
For details see general information section
Electrical data
Loop resistanceof pair / +20°C 52ohm/km
Pair capacitance / 800Hz 50nF/km
Loop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
20
�
�� � �
250V CABLES
RFA-HF 250VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm1x2x0,75 7,5 65 451x4x0,75 9,0 15 552x2x0,75 11,5 115 704x2x0,75 13,5 170 858x2x0,75 17,5 300 10510x2x0,75 20,0 365 12012x2x0,75 21,0 420 13014x2x0,75 22,5 485 13519x2x0,75 26,0 635 16024x2x0,75 29,0 780 175
21
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The four core cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue
DESIGN: STANDARDS:Twisted pair cable IEC 60092-3, design
1. Conductor- stranded copper conductor IEC 60228, class 2
2. Insulation- Mica tape- XLPE plastic IEC 60092-351
3. Bedding- filler tape
4. Armour- drain wire (in all sizes)
- copper wire braid, coverage > 94% IEC 60092-350
5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour green, other colours on request
250V
CAB
LES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Fire-resistant armouredinstrumentation and communicationcable 250V
RFE-FRHF
Application: For fixed installation in all areas and on open deck in ships
Main characteristics
Rated voltage 250V
Maximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Fire-resistant IEC 60331 series
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series
For details see general information section
Electrical data
Loop resistanceof pair / +20°C 52ohm/km
Pair capacitance / 800Hz 45nF/km
Loop inductance 0,6mH/km
Insulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
22
�
�� �
�
250V CABLES
RFE-FRHF 250VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm1x2x0,75 10,0 120 601x4x0,75 12,0 160 752x2x0,75 14,5 210 904x2x0,75 17,0 290 1057x2x0,75 20,5 460 1258x2x0,75 22,0 505 13510x2x0,75 25,0 610 15012x2x0,75 26,0 700 16014x2x0,75 28,0 780 17019x2x0,75 32,0 1005 19524x2x0,75 35,5 1210 215
23
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The four core cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue
Kvaerner Masa-Yards HKI
DESIGN: STANDARDS:Twisted pair cable IEC 60092-3, design1. Conductor
- stranded copper conductor IEC 60228, class 22. Insulation
- Mica tape- XLPE plastic IEC 60092-351
3. Individual screen- plastic coated aluminium tape and a ground conductor
4. Bedding- filler tape
5. Screen- drain wire (in all sizes)
- copper wire braid, coverage > 94% IEC 60092-3506. Sheath
- polyolefine plastic, SHF1 IEC 60092-359- standard colour green, other colours on request
250V
CAB
LES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Fire-resistant armoured andpair screened instrumentationand communication cable 250V
RFE-FRHF (i)
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 250VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Fire-resistant IEC 60331 seriesHalogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical dataLoop resistanceof pair / +20°C 52ohm/kmPair capacitance / 800Hz 55nF/kmLoop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
24
�
��� �
�
250V CABLES
RFE-FRHF (i) 250VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm2x2x0,75 15,0 225 904x2x0,75 17,0 325 1057x2x0,75 21,0 525 1308x2x0,75 22,0 580 13510x2x0,75 25,5 700 15512x2x0,75 26,5 805 16014x2x0,75 28,5 905 17519x2x0,75 32,5 1170 19524x2x0,75 36,0 1420 220
25
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....The pairs are also covered by a numbered tape (1, 2, 3, 4, 5....)
Kvaerner Masa-Yards HKI
60V
CABL
ES RFE-HF
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
DESIGN: STANDARDS:Twisted pair cable IEC 60092-375, design
1. Conductor- stranded copper conductor IEC 60228, class 2
2. Insulation- XLPE plastic
3. Bedding- filler tape
4. Armour- drain wire (in all sizes)- copper wire braid coverage > 94% IEC 60092-350
5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request
Armoured instrumentation andcommunication cable 60V
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 60VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical dataLoop resistanceof pair / +20°C 80ohm/kmPair capacitance / 800Hz 55nF/kmLoop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
26
�
�� � �
60V CABLES
RFE-HF 60VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm1x2x0,5 7,5 80 451x4x0,5 8,0 100 502x2x0,5 10,0 120 604x2x0,5 11,5 170 707x2x0,5 13,5 240 808x2x0,5 15,0 290 9010x2x0,5 16,5 340 10012x2x0,5 17,5 390 10514x2x0,5 18,5 430 11019x2x0,5 21,5 540 13024x2x0,5 23,5 650 14032x2x0,5 26,5 820 16037x2x0,5 28,5 910 175
27
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The four core cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue
Kvaerner Masa-Yards HKI
60V
CABL
ES
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
DESIGN: STANDARDS:Twisted pair cable IEC 60092-375, design
1. Conductor- stranded copper conductor IEC 60228, class 2
2. Insulation- XLPE plastic
3. Separator- separator tape
4. Screen- drain wire (in all sizes)
- aluminium polyester tape, IEC 60092-350 coverage 100%
5. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request
RFA-HF Screened instrumentation andcommunication cable 60V
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 60VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical dataLoop resistanceof pair / +20°C 80ohm/kmPair capacitance / 800Hz 55nF/kmLoop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
28
��� � �
60V CABLES
RFA-HF 60VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm1x2x0,5 6,0 45 401x4x0,5 7,0 65 452x2x0,5 9,5 80 604x2x0,5 10,5 110 657x2x0,5 13,0 170 808x2x0,5 13,5 185 8510x2x0,5 15,5 235 9512x2x0,5 16,5 260 10014x2x0,5 17,5 305 10519x2x0,5 20,5 395 12524x2x0,5 22,5 475 13537x2x0,5 28,0 730 170
29
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....
The four core cable is built up as a star quadwith the following identification1 core white2 core blue3 core white4 core blue
Kvaerner Masa-Yards HKI
60V
CABL
ES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
RFA-HF (i) Collectively and individually screenedinstrumentation and communicationcable 60V
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 60VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical dataLoop resistanceof pair / +20°C 80ohm/kmPair capacitance / 800Hz 80nF/kmLoop inductance 0,6mH/kmInsulation resistance / +20°C ≥1500Mohm*km
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
DESIGN: STANDARDS:Twisted pair cable IEC 60092-375, design1. Conductor
- stranded copper conductor IEC 60228, class 22. Insulation
- XLPE plastic IEC 60092-3513. Pair shielding
- plastic coated aluminium tape and a ground conductor
4. Separator- separator tape
5. Screen- drain wire (in all sizes) IEC 60092-350- aluminium polyester tape, coverage 100%
6. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour grey, other colours on request
30
���� �
�
60V CABLES
RFA-HF (i) 60VNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm2x2x0,5 11,0 95 704x2x0,5 13,0 140 807x2x0,5 14,0 215 858x2x0,5 15,5 240 9510x2x0,5 16,5 295 10012x2x0,5 18,0 340 11014x2x0,5 19,0 395 11519x2x0,5 23,0 530 14024x2x0,5 26,5 650 160
31
Other sizes on request.
Core identification
Each pair white - blue. Cores numbered 1, 2, 3, 4, 5....The pairs are covered by a numbered tape (1, 2, 3, 4, 5....)
60V
CABL
ES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
DAMA-HF Sreened data cable60V
Application: For fixed installation in all areas and on open deck in ships
Main characteristicsRated voltage 60VMaximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 seriesSmoke emission IEC 61034 seriesFor details see general information section
Electrical dataLoop resistanceof pair / +20°C 108ohm/kmConductor resistance / +20°C 53ohm/kmPair capacitance / 800Hz 42nF/kmInsulation resistance / +20°C ≥2000Mohm*kmCharacteristic imped-ance 1..16MHz 105 ± 10ohmAttenuation 1MHz 2,6dB/100mAttenuation 10MHz 6,0dB/100m
Minimum installation temperature -15 °CLowest operation temperature -40 °C
Identification: Lot number, cable type, cable size, voltage, temperature, standards,production month, manufacturer's name and meter marking printed on the sheath
DESIGN: STANDARDS:Twisted pair cable IEC 60092-3, design1. Conductor
- stranded copper conductor IEC 60228, class 22. Insulation
- Polyethylene / foamed polyethylene plastic 3. Pair shielding
- plastic coated aluminium tape and a ground conductor
4. Bedding- separator tape
5. Screen- drain wire- plastic coated aluminium tape and a ground conductor
6. Sheath - grey polyolefine plastic, SHF1 IEC 60092-359
32
�
�
�� � �
60V CABLES
DAMA-HFNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm4 x (2+1) x 0,34 12,0 140 75
4 x (2+1) x 0,5 14,0 180 85
Attenuation +20°C
1MHz 10MHz
2,6dB
6,0dB
103ohm
Characteristic impedance
1MHz 16MHz
115ohm
33
Core identification
Each pair green - red. The pairs are identified by a numbered tape.
Kvaerner Masa-Yards HKI
60V
CABL
ES
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
PBS Field bus cable60V
Application: For fixed installation in all areas.
Main characteristics
Rated voltage 60V
Maximum conductortemperature + 85 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3A -test for bunched wires and cables, category A
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series
Identification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheath
Core identification
Each pair green - red.
DESIGN: STANDARDS:Twisted pair cable EN 501701. Conductor
- stranded copper conductor2. Insulation
- Polyethylene / foamed polyethylene plastic3. Pair twisting4. Bedding
- separator tape5. Screen
- plastic coated aluminium tape and tinned copper braid, coverage > 75%
6. Sheath- purple, polyolefine plastic
7. Outer sheath - grey polyolefine plastic, SHF1
34
��
�� �
�
�
60V CABLES
PBSNumber of conductors & Nominal outer Approximate Min.bending radiuscross-section n x mm2 diameter mm weight kg/km fixed installation mm1 x 2 x 0,34 10,5 145 65
Cable for PROFIBUS DP.The cable has been tested according to the IEC 61158 specificationand testing guidelines set by PROFIBUS Center Nederland.Cable is approved as type A cable.
Compatible with the connector of Siemens (6ES7-972-0BA12 0XA0 or similar)after stripping the outer sheath.
Type A bus cable. Maximum length of each bus segment.
Data transfer rate in kbit/s 9.6 – 93.75 187.5 500 1500 3000 – 12000
Max. segment length in m 1200 1000 400 200 100
35
Kvaerner Masa-Yards HKI
- non-metallic- networks in shipboard applications- Fibres: 250 µm SM or MM fibres- 4 - 48 fibres
Cable characteristics: (for example FXMSU 2x6 SML + 3x4 GKL)Maximum pulling force 500 N EN 187000 method 501Crush strength / 100 mm (plate) 4000 N EN 187000 method 504Crush strength / 25 mm (mandrel) 650 N EN 187000 method 504Impact strength 30 J EN 187000 method 505Sheath marking Cable type, manufacturer, man. no.,
man. time, length marking in m.Minimum bending radius 140 mm during installation,
100 mm in final bendingNominal cable diameter 9.4 mmCable weight 75 kg/kmMinimum installation temperature -15 °COperating temperature range -45...+70 °CLongitudinal water tightness EN 187000 method 605B
Flame-retardant IEC 60332-1 -test for single insulated wire and cableIEC 60332-3A -test for bunched wires and cables,
category AHalogen-free IEC 60754 seriesSmoke emission IEC 61034 series
For details see general information section
Cable construction: (for example FXMSU 2x6 SML + 3x4 GKL)
1. Central element glass fibre, 1,5 mm
2. PP-slotted core, 6,0 mm
3. Optical fibres, 250 µm
4. Swellable tape
5. Rip cord
6. UV-protected and halogen free sheath
OPTI
CAL
FIBR
E CA
BLE
Tel. +358 2 410 8700, fax +358 2 410 8750, www.helkamabica.fi
FXMSU Optical fibreindoor/outdoor cable
✳. Slotted corecables haveblue and redmarker threadsfor the first andlast slotrespectively.
36
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
��
��
� �
OPTICAL FIBRE CABLE
Cable construction: (for example FXMMS 8 GKT)
1. FRP central element 2 mm
2. PP-slotted core 9,7 mm
3. Installation cable unit FMS 1 (2 mm)
4. fire barrier tape
5. rip cord
6. halogen free sheath 1,5 mm
FXMMS Optical fibreinstallation cable
- For tray installation- Fibres: 2–8 SM or MM fibres, 900 µm- Connectors can be mounted directly to the fibres
Cable characteristics: (for example FXMMS 8 SMT)Maximum pulling force 1500 N EN 187000 method 501Crush strength / 100 mm (plate) 4000 N EN 187000 method 504Crush strength / 25 mm (mandrel) 750 N EN 187000 method 504Impact strength, R = 300 mm 30 J EN 187000 method 505Sheath marking Cable type, manufacturer, man. no.,
man. time, length marking in m.Minimum bending radius 195 mm during installation, 130 mm in final bendingNominal cable diameter 13.1 mmCable weight 142 kg/kmMinimum installation temperature -15 °COperating temperature range -45...+70 °CFlame-retardant IEC 60332-1 -test for single insulated wire and cable
IEC 60332-3 -test for bunched wires and cables, category C
Halogen-free IEC 60754 series
Smoke emission IEC 61034 series
For details see general information section
37
Flame-retardantFire-resistantHalogen-freeLowsmokeemission
��
��
��
Multimode fibre Gl 50 / 125 µm
50 +/- 3 µm≤ 6 %≤ 3 µm125 +/- 2 µm≤ 2 %850 nm ≤ 2.7 dB/km1300 nm ≤ 0.8 dB/km850 nm ≥ 500 MHz x km1300 nm ≥ 800 MHz x kmNumerical aperture N.A. 0.200 +/- 0.015Fibre designation 6 colour systemcomplying with SFS 5648
Multimode fibre GK 62.5 / 125 µmEN 188 202
Core diameter 62.5 +/- 3 µmCore ellipticity ≤ 6 %Core eccentricity ≤ 3 µmCladding diameter 125 +/- 2 µmCladding ellipticity ≤ 2 %Fibre attenuation 850 nm ≤ 3.5 dB/km
1300 nm ≤ 1.0 dB/kmBandwidth 850 nm ≥ 200 MHz x km
1300 nm ≥ 500 MHz x kmNumerical aperture N.A. 0.275 +/- 0.015Fibre designation 6 colour systemcomplying with SFS 5648
Singlemode fibre SM ITU-T G.652EN 188 101
Mode field diameter 1310nm 9.3+/-0.5µmMode field eccentricity ≤ 1.0 µm- installation cables ≤ 0.5 µmCladding diameter 125 +/-2µm- installation cables 125 +/-1µmCladding ellipticity ≤ 2 %Fibre attenuation 1310 nm ≤ 0,40 dB/km
1550 nm ≤ 0,25 dB/kmZero dispersion range 1300...1324 nmDispersion coefficient ≤ 0.093 ps/nm2/km- dispersion at 1550 nm ≤18 ps/nm/kmCut-off wavelength ≤ 1260 nm- installation cables 1180...1250 nmPolarization mode dispersion ≤ 0.5 ps/√kmProof test 1 % strain, 1 s durationFibre designation 6 colour systemcomplying with SFS 5648