| Pressure | Temperature | Force
Pressure Sensors, Pressure Switches,Pressure Transducers, Digital Indicators,Handheld Pressure Measuring Instruments
7
Selection guide for pressure sensors, pressure switches,pressure transducers, digital indicators andhand-held measuring instruments Page 80-81
Pressure Sensors
for general application Page 82-85Compact 0.5% Page 86Miniature Page 87Compact 1.0% Page 88for mobile hydraulics Page 88OEM Page 89“MagTrans” Page 90for refrigeration Page 91Precision Page 92-93according to ATEX 100a Page 94-95for submersible pressure measurement Page 96for highest pressure Page 97for food industry Page 98for low and differential pressure Page 99
Pressure Transducers
digital pressure gauge Page 100with local indication Page 100“DigiTrans” Page 101
Pressure Switches
“MagSwitch” Page 102-103mechanical Page 104-105electronic Page 106-107
Digital Indicators
attachable indicator Page 108with microprocessor Page 108
Hand-held Pressure Measuring Instruments
“Manoport” with internal sensor Page 109“Manoport” with external sensor Page 110-111
Test certificates
DKD certificate, Test certificate Page 112
Industrial Pressure Sensor
Selection guide for pressure sensors
for general applicationsAccuracy Pressure range [bar] Model Price list
0,025 0,1 0,25 0,4 1 16 25 600 1000 1600 2500 page0,5% 3275 83
327633763245 8332493349 863247
1,0% 3272337333963296 8932963301 90
Explanation: Gauge pressure Absolute pressure
for special applicationsPreisliste
Pressure sensors Application Seite
front flush for pasty or crystallizing media 84
Miniature for extrem space-saving installation 87
Mobile hydraulics for safety requirements in area of hydraulic operations 88
Refrigeration for use in refrigeration applications 91
Precision for use in testing or calibration systems 92
for use in potentially explosive application 94
Submersible for hydrostatic level measurement 96
High pressure for highest pressure up to 8000 bar 98
Food industry for use in food industry 97
Differential pressure for low and differential pressure 99
New Pressure Sensor for the Mobile Hydraulic: "Mobiltrans"
- High quantities at attractive prices- Compact design- Extrem Shock and Vibration resistance- High EMI Protection (100 V/m)- Excellent temperature performance- Resistance to pressure peaks (CDS system)
Now available!Price on request Technical data see DE762
88
82
80Industrial Pressure Sensor
Selection guide for Pressure Switches, Pressure Transducers,Digital Indicators and Hand-held Pressure Measuring Instruments
Price list
Pressure Transducers Application pagefor digital indication, battery-supplied 100
for analog indication with analog output 100
DigiTrans for digital indication and freely programmable pressure ranges 101
Price list
Pressure Switches Design / Application pagemechanical Miniature ; standard version 104
mechanical with rotatable case; manifold style 105
electronic for OEM applications "MagSwitch" 102
electronic completely programmable 106
electronic with display 107
Price list
Digital Indication Application pagefor direct connection to the pressure sensor 108
Informator LED 4 - digit for panel mounting 48 x 24 mm 108
Informator LED 5 - digit for panel mounting 96 x 48 mm 108
Hand-Held Pressure Price list
Measuring Instrument Application pagefor mobile pressure measurement 109
for mobile pressure measurement 110
Additional informationto our products
is available under
www.tecsis.de
Digital pressure gauge
with external pressure sensor
Attachable indcator
with local indication
with integrated pressure sensor
81
Industrial Pressure Sensor
Pressure Sensors for general Applications
Model 3376 3276 3377 3277
Accuracy %Output 4...20mA 0...10 VDC 4...20mA 0...10 VDC 4...20mA 0...10 VDC 4...20mA 0...10 VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread G 1⁄2 B from 0 ... 2500 bar: M 16 x 1,5 (female)Case stainless steelPressure conn. stainless steelMedia temperature -30 ... +100°CProtection type IP 65Datasheet DE 700Measuring ranges Code Code Code Code Code Code Code Code
bar no no no no no no no noEUR/unit
1 - 9 308,00 352,00 350,00 394,00 10 - 19 246,10 281,60 279,60 315,00
20+ on request on request on request on request -0,1 ... 0 011 001 011 101 -0,16... 0 012 001 012 101 -0,25... 0 013 001 013 101 013 001 013 101 -0,4 ... 0 014 001 014 101 014 001 014 101 -0,6 ... 0 015 001 015 101 015 001 015 101 -1...0 016 001 016 101 016 001 016 101 -1...0...+ 1,5 043 001 043 101 043 001 043 101 -1...0...+ 5 045 001 045 101 045 001 045 101EUR/unit
1 - 9 271,70 316,00 271,70 316,00 313,00 358,00 313,00 358,00 10 - 19 217,50 253,00 217,50 253,00 250,80 286,30 250,80 286,30
20+ on request on request on request on request on request on request on request on request 0... 0,1 063 001 063 101 0... 0,16 064 001 064 101 0... 0,25 065 001 065 101 065 001 065 101 0... 0,4 066 001 066 101 066 001 066 101 0... 0,6 067 001 067 101 067 001 067 101 0... 1 069 001 069 101 069 001 069 101 0... 1,6 070 001 070 101 070 001 070 101 0... 2,5 072 001 072 101 072 001 072 101 0... 4 073 001 073 101 073 001 073 101 0... 6 074 001 074 101 074 001 074 101 0... 10 075 001 075 101 075 001 075 101 0... 16 076 001 076 101 076 001 076 101 0... 25 078 001 078 101 078 001 078 101 0... 40 079 001 079 101 079 001 079 101 0... 60 080 001 080 101 080 001 080 101 0... 100 081 001 081 101 081 001 081 101 0... 160 082 001 082 101 082 001 082 101 0... 250 084 001 084 101 084 001 084 101 0... 315 085 001 085 101 085 001 085 101 0... 400 086 001 086 101 086 001 086 101 0... 600 087 001 087 101 087 001 087 101 0...1000 088 001 088 101 088 001 088 101EUR/unit
1 - 4 1091,00 1136,00 1133,00 1177,00 5 - 9 873,00 909,00 907,00 941,00
10+ on request on request on request on request 0 ... 1600 089 001 089 101 089 001 089 101 0 ... 2500 1) 090 001 090 101 090 001 090 101
Accessoires: see chapter 12Special versions: see page 83
Order sample: model 3276 + code no. 011 001 = article no. 3276.011.001 1) M 16 x 1,5 (innen)Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
0,5 0,25
82
Pressure Sensors for general Applications
absolute pressureModel 3245 3248 3275
Accuracy % 0,5 0,25 0,5Output 4...20 mA 0 ... 10VDC 4...20 mA 0 ... 10VDC 4...20mA 0...10 VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread G 1⁄2 B Case stainless steelPressure conn. stainless steel stainless steel; Si; Al; AuMedia temperature -30 ... +100°CProtection type IP 65Datasheet DE 700Measuring ranges Code Code Code Code Meas. ranges Code Code
bar/abs no no no no mbar no noEUR/unit EUR/unit
1 - 9 311,00 356,00 353,00 398,00 1 - 4 318,00 362,00 10 - 19 249,30 284,80 282,60 318,00 5 - 9 254,50 290,00
20+ on request on request on request on request 10+ on request on request0... 0,25 065 001 065 101 065 001 065 101 0 ... 25 060 001 060 1010... 0,4 066 001 066 101 066 001 066 101 0 ... 40 061 001 061 1010... 0,6 067 001 067 101 067 001 067 101 0 ... 60 062 001 062 1010... 1 069 001 069 101 069 001 069 1010... 1,6 070 001 070 101 070 001 070 1010... 2,5 072 001 072 101 072 001 072 1010... 4 073 001 073 101 073 001 073 101 10+ on request on request0... 6 074 001 074 101 074 001 074 101 -25 ... 0 008 001 008 0010... 10 075 001 075 101 075 001 075 101 -40 ... 0 009 001 009 0010... 16 076 001 076 101 076 001 076 101 -60 ... 0 010 001 010 001
Surcharges for special versions 3245Model 3376 3276 3277 3377 3248 3275SurchargeMeasuring ranges 0 ... 4000 bar
otherElectr. connection
connector M12x1, 4-pin, IP67cable output, 1 m, IP67
each additional m cablebuild-in connector, 5-pin, IP67
Output 0 ... 20 mA 3-wire0 ... 5VDC 3-wire
Pressure conn. G 1⁄4 B (max.1000 bar)1⁄4 NPT (max.1000 bar)1⁄2 NPT (max.1600 bar)
operating temperature -40 ... 125 °CSpecial versions
free of oil and greaseoxygen; incl. free of oil and grease 1)GL-approval
Test certificate resp. DKD calibration certificate see page 112
Accessoires see chapter 12junction boxfor angular connector form a ZE41.011.003junction box for M12x1 plug with 2m cable
straight ZE53.011.010angled ZE53.011.011
Order sample: model 3245 + code no. 011 001 = article no. 3245.011.001 1) from 0 ... 0,25 to 0 ... 1600 barBold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
83
Pressure Sensors with front flush diaphragm
Model 3386 3251 3344 3252
Accuracy % 0,5 0,25Output 4...20 mA 0...10 VDC 4...20 mA 0...10 VDC 4...20 mA 0...10 VDC 4...20 mA 0...10 VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread G 1⁄2 B front flush up to 0 ... 1,6 bar G 1 BCase stainless steelPressure conn. stainless steel, NBR O-Ring Media temperature -30 ... +100°CProtection type IP 65Datasheet DE 701Measuring ranges Code Code Code Code Code Code Code Code
bar no no no no no no no noEUR/unit
1 - 9 340,00 385,00 381,00 426,00 10 - 19 272,20 308,00 306,00 341,00
20+ on request on request on request on request -0,25...0 013 001 013 101 013 001 013 101 -0,4... 0 014 001 014 101 014 001 014 101 -0,6... 0 015 001 015 101 015 001 015 101 -1 ... 0 016 001 016 101 016 001 016 101 -1 ...0...+ 1,5 043 001 043 101 043 001 043 101 -1 ...0...+ 5 045 001 045 101 045 001 045 101EUR/unit
1 - 9 304,00 349,00 304,00 349,00 346,00 390,00 346,00 390,00 10 - 19 243,10 278,50 243,10 278,50 276,40 312,00 276,40 312,00
20+ on request on request on request on request on request on request on request on request0... 0,1 063 001 063 1010... 0,16 064 001 064 1010... 0,25 065 001 065 101 065 001 065 1010... 0,4 066 001 066 101 066 001 066 1010... 0,6 067 001 067 101 067 001 067 1010... 1 069 001 069 101 069 001 069 1010... 1,6 070 001 070 101 070 001 070 1010... 2,5 072 001 072 101 072 001 072 1010... 4 073 001 073 101 073 001 073 1010... 6 074 001 074 101 074 001 074 1010... 10 075 001 075 101 075 001 075 1010... 16 076 001 076 101 076 001 076 1010... 25 078 001 078 101 078 001 078 1010... 40 079 001 079 101 079 001 079 1010... 60 080 001 080 101 080 001 080 1010... 100 081 001 081 101 081 001 081 1010... 160 082 001 082 101 082 001 082 1010... 250 084 001 084 101 084 001 084 1010... 400 086 001 086 101 086 001 086 1010... 600 087 001 087 101 087 001 087 101
Accessoires: see chapter 12Special versions: see page 85
Order sample: model 3251 + code no. 075 001 = article no. 3251.075.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
84
Pressure Sensors with front flush diaphragm
absolute pressureModel 3255 3256
Accuracy % 0,5 0,25Output 4...20 mA 0 ... 10VDC 4...20 mA 0 ... 10VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread G 1⁄2 B front flush up to 0 ... 1,6 bar G 1 BCase stainless steelPressure conn. stainless steel, NBR O-Ring Media temperature -30 ... +100°CProtection type IP 65Leaflet DE 701Measuring ranges Code Code Code Code
bar no no no noEUR/unit
1 - 9 344,00 388,00 386,00 429,00 10 - 19 274,80 310,00 308,00 344,00
20+ on request on request on request on request0... 0,25 065 001 065 101 065 001 065 1010... 0,4 066 001 066 101 066 001 066 1010... 0,6 067 001 067 101 067 001 067 1010... 1 069 001 069 101 069 001 069 1010... 1,6 070 001 070 101 070 001 070 1010... 2,5 072 001 072 101 072 001 072 1010... 4 073 001 073 101 073 001 073 1010... 6 074 001 074 101 074 001 074 1010... 10 075 001 075 101 075 001 075 1010... 16 076 001 076 101 076 001 076 101
Surcharges for special versionsModel 3386 3251 3344 3252 3255 3256SurchargeMeasuring range otherElectr. connection
connector M12x1, 4-pin, IP67cable output, 1 m, IP67
each additional m cablebuild-in connector, 5-pin, IP67
Outout 0 ... 20 mA 3-wire0 ... 5VDC 3-wire
Wetted parts Viton O-RingHastelloy C4PFA coated
Media temperature -40 ... 125 °Cintergr. Cooling element -10 ... 150 °C
Special versionsfree of oil and greaseoxygen; incl. free of oil and grease 1)
Test certificate resp. DKD calibration certificate
AccessoiresWeld-on adapter for front flush diaphragm
G 1 B ZM23.031.004G 1/2 B ZM23.031.006
junction box for angular connector form A ZE41.011.003junction box for M12x1 plug with 2m cable
straight ZE53.011.010angled ZE53.011.011
1) from 0...2,5 bar up to 0...160 bar
Order sample: model 3255 + code no. 075 001 = article no. 3255.075.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
85
Pressure Sensors Kompakt 0.5%
absolute pressureModel 3349 3249 3247
Accuracy % 0,5Output 4...20mA 0...10 VDC 4...20mA 0...10 VDC 4...20mAPower supply 10...30 VDC 14...30VDC 10...30 VDC 14...30 VDC 10...30 VDCElectr. connection plug to DIN EN 175301-803 form C with junction boxThread G 1⁄4 BCase stainless steelPressure conn. stainless steelMedia temperature -30 ... +100°CProtection type IP 65Datasheet DE 705Meßbereiche Code Code Code
bar no no noEUR/unit
1 - 9 242,50 281,60 10 - 19 194,00 225,30
ab 20 auf Anfrage auf Anfrage -0,25...0 013 001 013 101 -0,4 ...0 014 001 014 101 -0,6 ...0 015 001 015 101 -1 ...0 016 001 016 101EUR/unit
1 - 9 206,60 245,60 206,60 245,60 246,10 10 - 19 165,30 196,70 165,30 196,70 197,20
ab 20 auf Anfrage auf Anfrage auf Anfrage auf Anfrage auf Anfrage 0... 0,25 065 001 065 101 065 001 0... 0,4 066 001 066 101 066 001 0... 0,6 067 001 067 101 067 001 0... 1 069 001 069 101 069 001 0... 1,6 070 001 070 101 070 001 0... 2,5 072 001 072 101 072 001 0... 4 073 001 073 101 073 001 0... 6 074 001 074 101 074 001 0... 10 075 001 075 101 075 001 0... 16 076 001 076 101 076 001 0... 25 078 001 078 101 0... 40 079 001 079 101 0... 60 080 001 080 101 0... 100 081 001 081 101 0... 160 082 001 082 101 0... 250 084 001 084 101 0... 400 086 001 086 101 0... 600 087 001 087 101 0...1000 088 001 088 101
Surcharges for special versionsModel 3349 3247 3249Surcharge EUR/unitElectr. connection connector M12x1, 4-pin, IP67
cable output, 1 m, IP67 each additional m cable
Output signal 0 ... 20 mA 3-wire0 ... 10 VDC or 0 ... 5 VDC 3-wire
Pressure connn. 1/4 NPTMedia temperature -40 ... 125 °CSpecial versions free of oil an gease
oxygen; incl. free of oil and geaseTest certificate resp. DKD calibration certificate
Accesoriesjunction box for angular connector form C ZE41.011.004connector M12x1 with 2m cable, straight ZE53.011.010
M12x1 whit 2m cable, angled ZE53.011.011
Order sample: model 3249 + code no. 075 001 = article no. 3249.075.001Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
Codeno
Codeno
86
Pressure Sensors Miniaturewith internal diaphragm with front flush diaphragm
Model 3325 3326
Accuracy % 0,5Output 4...20mA 0,1...10 VDC 4...20mA 0,1...10 VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection plug M12x1, 4-pinThread G 1/4 A to DIN 3852 E G 1/4 A front flush Case stainless steelPressure conn. stainless steel stainless steel, NBR O-Ring Media temperature -40 ... +100°CProtection type IP 65Datasheet DE 755Measuring ranges Code Code Code
bar no no noEUR/unit
1 - 9 222,70 222,70 238,10 238,10 10 - 19 189,30 189,30 202,40 202,40
ab 20 on request on request on request 0... 16 076 001 076 101 0... 25 078 001 078 101 078 001 078 101 0... 40 079 001 079 101 079 001 079 101 0... 60 080 001 080 101 080 001 080 101 0... 100 081 001 081 101 081 001 081 101 0... 160 082 001 082 101 082 001 082 101 0... 250 084 001 084 101 084 001 084 101 0... 400 086 001 086 101 086 001 086 101 0... 600 087 001 087 101 087 001 087 101 0...1000 088 001 088 101
Surcharges for special versionsModel 3325 3326Surcharge EUR/unitElectr. connection connector M12x1, 4-pin, IP67
plug DIN EN 175301-803 form C with junction boxcable output, 1 m, IP67
each additional m cableOutput signal 1 ... 5 VDC 3-wirePressure connn. 1/4 NPT
G 1/4 BSpecial versions free of oil an gease
oxygen; incl. Free of oil and geaseTest certificate resp. DKD calibration certificate see page 112
Accesories see chapter 12junction box for angular connector form C ZE41.011.004connector M12x1 with 2m cable, straight ZE53.011.010
M12x1 whit 2m cable, angled ZE53.011.011
Order sample: model 3325 + code no. 075 001 = article no. 3325.075.001Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
Codeno
on request
87
Pressure SensorCompact 1% for Mobile Hydraulics
Model 3373 3272 3374
Accuracy % 1.0Output 4...20mA 0...10 VDC 4...20mA 0...10 VDC 4...20mA 1...5 VPower supply 10...30 VDC 14...30VDC 10...30 VDC 14...30 VDC 10...30 VDC 10...30 VDCElectr. connection plug G4A1MMT Hirschmann-Mini with junction box Round plug connector M12x1, 4-pinThread G 1⁄4 B G 1⁄4 B to DIN 3852-ECase stainless steelPressure conn. stainless steelMedia temperature -30 ... +100°C -40 ... +125°CProtection type IP 65 IP67Datasheet DE 706 DE 754Measuring ranges Code Code Code Code Code Code
bar no no no no no noEUR/unit
1 - 9 171,60 205,40 171,60 205,40 165,50 199,40 10 - 19 137,20 164,30 137,20 164,30 132,40 159,50
20+ on request on request on request on request on request on request 0... 0,25 065 001 065 101 0... 0,4 066 001 066 101 0... 0,6 067 001 067 101 0... 1 069 001 069 101 0... 1,6 070 001 070 101 0... 2,5 072 001 072 101 0... 4 073 001 073 101 0... 6 074 001 074 101 0... 10 075 001 075 101 0... 16 076 001 076 101 0... 25 078 001 078 101 0... 40 079 001 079 101 0... 60 080 001 080 101 080 001 080 501 0... 100 081 001 081 101 081 001 081 501 0... 160 082 001 082 101 082 001 082 501 0... 250 084 001 084 101 084 001 084 501 0... 400 086 001 086 101 086 001 086 501 0... 600 087 001 087 101 087 001 087 501 0...1000 088 001 088 101
Surcharges for special versionsModel 3373 3272 3374Surcharge EUR/unitMeasuring ranges otherElectr. connection connector M12x1, 4-pin, IP67
plug DIN EN 175301-803 form C with junction boxcable output, 1 m, IP67 IP69K for Model 3374
each additional m cableOutput signal 0 ... 20 mA 3-wire
0 ... 5 VDC 3-wireother
Pressure conn. G 1/2 B, 1/2 NPT1/4 NPT
Media temperature -40 ... 125 °CSpecial versions free of oil an grease
oxygen; incl. free of oil and greaseTest certificate resp. DKD calibration certificate see page 112
Accessoires see chapter 12junction box for angular connector form C ZE41.011.004connector Mini Hirschmann ZE41.011.001
M12x1 with 2m cable, straight ZE53.011.010M12x1 wiht 2m cable, angled ZE53.011.011
Order sample: model 3272 + code no. 075 001 = article no. 3272.075.001Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
88
Pressure Sensors OEM
absolute pressureModel 3396 3296
Accuracy % 1,00Output 4...20mA 0...10 VDC 4...20mA 0...10 VDC 4...20mA 0...10 VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread G 1/4 BCase stainless steelPressure conn. stainless steelMedia temperature -40 ... +100°CProtection type IP 65Datasheet DE 707Measuring ranges Code Code Code Code Code Code
bar no no no no no noEUR/unit
1 - 49 108,00 108,00 108,00 108,00 126,80 126,80 50 - 99 87,50 87,50 87,50 87,50 102,60 102,60
100+ on request on request on request on request on request on request 0... 1 069 001 069 101 069 002 069 102 0... 1,6 070 001 070 101 070 002 070 102 0... 2,5 072 001 072 101 072 002 072 102 0... 4 073 001 073 101 073 002 073 102 0... 6 074 001 074 101 074 002 074 102 0... 10 075 001 075 101 075 002 075 102 0... 16 076 001 076 101 0... 25 078 001 078 101 0... 40 079 001 079 101 0... 60 080 001 080 101 0... 100 081 001 081 101 0... 160 082 001 082 101 0... 250 084 001 084 101 0... 400 086 001 086 101 0... 600 087 001 087 101 0...1000 088 001 088 101
Surcharges for special versionsModelSurcharge EUR/unitMeasuring ranges otherElectr. connection connector M12x1, 4-pin, IP67
cable output, 1 m, IP67each additional m cable
Output 1 ... 5 V 3-wire1 ... 6 V 3-wire
Pressure conn. G 1/2 B1/4 NPT
Special versionsfree of oil an greaseoxygen; incl. free of oil and greaseGL-approval
Test certificate resp. DKD calibration certificate
Accessoiresjunction box for angular connector connector form A ZE41.011.003
M12x1 with 2m cablestraight ZE53.011.010angled ZE53.011.011
Order sample: model 3296 + code no. 075 001 = article no. 3296.075.001Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
3396 3296
89
Pressure Sensor "MagTrans"
Model 3301
Accuracy 1.0 (typical)Output 0 ... 10 VDC 0 ... 5 VDCPower supply 12 ... 30 VDC 8 ... 30 VDCElectr. connection round connector M12x1, 4-pin Thread 1) G 1/4 BCase brassPressure conn. brassMedia temperature -20 ... 80 °CProtection type IP 65Datasheet DE 711Measuring ranges Code Code
bar no noEUR/unit
1 - 49 54,10 54,1050 - 99 43,90 43,90 100+ 36,70 36,70
- 0,1 ...0 011 101 011 201- 0,16...0 012 101 012 201- 0,25...0 013 101 013 201- 0,4 ...0 014 101 014 201- 0,6 ...0 015 101 015 201- 1 ...0 016 101 016 201EUR/unit
1 - 49 54,10 54,1050 - 99 43,90 43,90 100+ 36,70 36,70
0... 0,1 063 101 063 2010... 0,16 064 101 064 201 0... 0,25 065 101 065 2010... 0,4 066 101 066 201 0... 0,6 067 101 067 2010... 1 069 101 069 2010... 1,6 070 101 070 2010... 2,5 072 101 072 2010... 4 073 101 073 2010... 6 074 101 074 2010... 10 075 101 075 2010... 16 076 101 076 2010... 25 078 101 078 201
Surcharges for special versionsModel 3301Surcharge EUR/unitMeasuring ranges otherElectr. connection cable output, 2 m, IP67
each additional m cableOutput signal 0,5 ... 4,5 VDC ratiom. price reduction
1 ... 5 VDC 3-wire1 ... 6 VDC 3-wire
Pressure conn. G1/81/4 NPTother
Wetted parts stainless steeloxygen; incl. free of oil and greaseTest certificate resp. DKD calibration certificate
Accessoiresjunction box for M12x1 connector with 2m cable
straight ZE53.011.010angled ZE53.011.011
Order sample: Model 3301 + code no. 075 101 = article no. 3296.075.101Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
90
Pressure Sensors for refrigeration
Model
Accuracy 1.0OutputPower supplyElectr. connection plug to DIN EN 175301-803 form A with junction boxThread 7/16-20 UNF 2B / SchraderCase stainless steelPressure conn. stainless steelMedia temperature -25 ... +80°CProtection type IP 65Datasheet AE 731Measuring ranges
barEUR/unit
1 - 9 10 - 49
ab 50-0,8... 7-1... 9-1... 15-1... 24EUR/unit
1 - 9 10 - 49
ab 50 0... 18 0... 30 0... 40
Accessoires see chapter 12junction box for angular connector form A ZE41.011.003
Order sample: model 3309 + code no. 046 084 = article no. 3309.046.084Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
Additional informationto our products
is available under
www.tecsis.de
3309
0...10 VDC14...30 VDC
4...20mA12...30 VDC
62,00494 181046 181
75,3089,10
Codeno
046 084049 084051 084
049 181051 181
Codeno
89,1075,3062,00
62,00
89,1075,3062,00
89,1075,30
494 084
496 181133 181079 181
496 084133 084079 084
91
Pressure Sensors Precisionwith internal diaphragm with front flush diaphragm
Model 3382 3383
Accuracy %Output 4...20 mA 0...10 VDC 4...20 mA 0...10 VDCPower supply 10...30 VDC 14...30 VDC 10...30 VDC 14...30 VDCElectr. connection cable outlet, 1,5 mThread G 1⁄2 B G 1⁄2 B front flush G1 B up to 0...1,6 bar
Case stainless steel Pressure conn. stainless steel stainless steel, NBR O-ring Media temperature -20...80°CProtection type IP67Datasheet DE 715 DE 716Measuring ranges Code Code Code Code
bar no no no noEUR/unit
1 - 4 683,00 727,00 714,00 759,00 5 - 9 621,00 662,00 651,00 691,00
10+ on request on request on request on request -0,25...0 013 001 013 101 013 001 013 101 -0,4 ...0 014 001 014 101 014 001 014 101 -0,6 ...0 015 001 015 101 015 001 015 101 -1 ...0 016 001 016 101 016 001 016 101 -1 ...0...+ 0,6 042 001 042 101 042 001 042 101 -1 ...0...+ 1,5 043 001 043 101 043 001 043 101 -1 ...0...+ 3 044 001 044 101 044 001 044 101 -1 ...0...+ 5 045 001 045 101 045 001 045 101EUR/unit
1 - 4 648,00 692,00 678,00 723,00 5 - 9 589,00 629,00 617,00 658,00
10+ on request on request on request on request0... 0,25 065 001 065 101 065 001 065 1010... 0,4 066 001 066 101 066 001 066 1010... 0,6 067 001 067 101 067 001 067 1010... 1 069 001 069 101 069 001 069 1010... 1,6 070 001 070 101 070 001 070 1010... 2,5 072 001 072 101 072 001 072 1010... 4 073 001 073 101 073 001 073 1010... 6 074 001 074 101 074 001 074 1010... 10 075 001 075 101 075 001 075 1010... 16 076 001 076 101 076 001 076 1010... 25 078 001 078 101 078 001 078 1010... 40 079 001 079 101 079 001 079 1010... 60 080 001 080 101 080 001 080 1010... 100 081 001 081 101 081 001 081 1010... 160 082 001 082 101 082 001 082 1010... 250 084 001 084 101 084 001 084 1010... 400 086 001 086 101 086 001 086 1010... 600 087 001 087 101 087 001 087 1010...1000 088 001 088 101
Accessoires: see chapter 12Special versions: see page 93
Order sample: model 3382 + code no. 075 001 = article no. 3382.075.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
0.1
92
Surcharges for special versionsModel 3382 3383SurchargeMeasuring ranges
absolute pressure 0...0,25 bar to 0...16 barother
Accuracy 0,05% 0...0,4 bar to 0...1000 barElectr. connection
connector M12x1, 4-pin, IP67cable longer than 1,5 m (each m)
Output 4 ... 20 mA 3-wire0 ... 5 VDC 3-wire 1)
RS 232 interface 2)
Pressure connection G 1⁄4 B1⁄4 NPT1⁄2 NPT
Wetted partsViton O-ringHastelloy C4 3)
PFA coatedSpecial versions
free of oil and greaseoxygen, free of oil and grease 4)
up to 0 ... 16 barfrom 0 ... 25 bar
Test certificate resp. DKD calibration certificate
Accessoiresjunction box for M12x1 connector with 2 m cable
straight ZE53.011.010angled ZE53.011.011
weld-on adapter for front flush diaphragmG 1 B ZM23.031.004G 1⁄2 B ZM23.031.006
cable set for service 5) ZE 53.050.006
1) power supply: 14...30 VDC 3) up to 0...16 bar 2) with 9-pin Sub-D-plug 4) for model 3383 up to 0...160 bar incl. program for data coverage 5) for adjustment of zero and span; incl. program for data coverage
Electronic test gauge"DigiComb"
ApplicationsMonitoring of test equipementTest and calibration technologyPrecision measurement
price on request
AE 727
Order sample: model 3382 + code no. 075 001 = article no. 3382.075.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
93
-Pressure Sensors according to ATEX 100awith internal diaphragm with front flush diaphragm
Model
Accuracy %Output 4...20 mA, EEx ia II C T4 - T6Power supply 10 ... 30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread G 1⁄2 B from 0...2500 bar: M 16 x 1,5 (female) G 1⁄2 B front flush up to 0 ... 1,6 bar: G 1 BCase stainless steelPressure conn. stainless steel stainless steel, NBR O-ringMedia temperature -30 ... +100°CProtection type IP 65Datasheet DE 722Measuring ranges Code Code Code Code
bar no no no noEUR/unit
1 - 4 341,00 383,00 372,00 414,00 5 - 9 307,00 345,00 336,00 373,00
10+ on request on request on request on request0 ... 0,1 063 001 063 0010 ... 0,16 064 001 064 0010... 0,25 065 001 065 001 065 001 065 0010... 0,4 066 001 066 001 066 001 066 0010... 0,6 067 001 067 001 067 001 067 0010... 1 069 001 069 001 069 001 069 0010... 1,6 070 001 070 001 070 001 070 0010... 2,5 072 001 072 001 072 001 072 0010... 4 073 001 073 001 073 001 073 0010... 6 074 001 074 001 074 001 074 0010... 10 075 001 075 001 075 001 075 0010... 16 076 001 076 001 076 001 076 0010... 25 078 001 078 001 078 001 078 0010... 40 079 001 079 001 079 001 079 0010... 60 080 001 080 001 080 001 080 0010... 100 081 001 081 001 081 001 081 0010... 160 082 001 082 001 082 001 082 0010... 250 084 001 084 001 084 001 084 0010... 400 086 001 086 001 086 001 086 0010... 600 087 001 087 001 087 001 087 0010...1000 088 001 088 001EUR/unit 1161,00 1203,000...1600 089 001 089 0010...2500 090 001 090 0010...4000 091 001 091 001
Accessoires: see chapter 12Special versions: see page 95
Order sample: model E110 + code no. 075 001 = article no. E110.075.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
0.25
E110 E111 E120 E121
0.5 0.25 0.5
94
-Pressure Sensors according to ATEX 100awith internal diaphragm with front flush diaphragm submersible
absolute pressure absolute pressure Model E112 E113 E122 E123 E130 E131
Accuracy % 0.5 0.25 0.5 0.25 0.5 0.25Output 4...20 mA, EEx ia IIC T4 - T6Power supply 10....30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction box 1,5 m cable (PUR)Thread G 1⁄2 B G 1⁄2 B front flush up to 0...1,6 bar: G 1 B G 1⁄2 B under protection capCase stainless steelPressure conn. stainless steelMedia temperature -30 ... 100°C -10 ... 60°CProtection type IP 65 IP 68Datasheet DE 722 DE 724Measuring ranges Code Code Code Code Code Code
bar no no no no no noEUR/unit
1 - 4 380,00 422,00 412,00 454,00 427,00 469,00 5 - 9 343,00 380,00 371,00 408,00 385,00 422,00
10+ on request on request on request on request on request on request0... 0,1 063 0010... 0,16 064 0010... 0,25 065 001 065 001 065 001 065 001 065 001 065 0010... 0,4 066 001 066 001 066 001 066 001 066 001 066 0010... 0,6 067 001 067 001 067 001 067 001 067 001 067 0010... 1 069 001 069 001 069 001 069 001 069 001 069 0010... 1,6 070 001 070 001 070 001 070 001 070 001 070 0010... 2,5 072 001 072 001 072 001 072 001 072 001 072 0010... 4 073 001 073 001 073 001 073 001 073 001 073 0010... 6 074 001 074 001 074 001 074 001 074 001 074 0010... 10 075 001 075 001 075 001 075 001 075 001 075 0010... 16 076 001 076 001 076 001 076 001 076 001 076 0010... 25 078 001 078 001
Surcharges for special versionsE110 E112 E120 E122 E130
Model E111 E113 E121 E123 E131Surcharge EUR/unitMeasuring range otherElectrical connection
Mil-plug, 6-pin, IP67Snap Cap, IP67cable output, 1 m, IP67
each addiotional m cableTeflon cable, IP68
each additional m teflon cableother
Pressure connect. G 1⁄4 B (max.1000 bar)1⁄4 NPT (max.1000 bar)1⁄2 NPT (max.1600 bar)
Wetted parts Viton O-ringHastelloy C4
Special versionsattached to zone 0build-in zone 0free of oil and greaseoxygen, incl. Free of oil and grease 1)
up to 0 ... 16 barfrom 0 ... 25 bar
Test certificate resp. DKD calibration certificate
AccessoiresWeld-in adapter for front flush diaphragm
G 1 B ZM23.031.004G 1⁄2 B ZM23.031.006
Junction box forMIL-plug, 6-pin ZE41.016.004angular connector form A ZE41.011.005
Supply transformer to ATEX 100a ZE08.030.003
Order sample: model E112 + code no. 075 001 = article no. E112.075.001 1) from 0...0,25 bar up to 0...160 bar for front flush diaphragmBold printed code no. ... delivery ex stock upt to 0...1600 bar for internal diaphragmother code no. ... note deliverytimes and minimum order value
95
Pressure Sensors for Submersible Pressure Measurement
Model 3233 3230
Accuracy 0.5 0.25Output 4...20 mA 4...20 mA 0...10 VDCPower supply 10...30 VDC 10...30 VDC 14...30 VDCElectr. connection 1.5 m cableThread G 1⁄2 B under protection capCase stainless steel Pressure conn. stainless steel Media temperature -10 ... 50°CProtection type IP68Datasheet DE725Measuring ranges
barEUR/unit
1 - 4 299,90 444,00 5 - 9 272,40 397,00 ab 10 auf Anfrage auf Anfrage
0... 0,1 063 001 063 1010... 0,16 064 001 064 1010... 0,25 065 001 065 001 065 101 0... 0,4 066 00 066 001 066 1010... 0,6 067 001 067 001 067 1010... 1 069 001 069 001 069 1010... 1,6 070 001 070 001 070 1010... 2,5 072 001 072 001 072 1010... 4 073 001 073 001 073 1010... 6 074 001 074 001 074 1010... 10 075 001 075 001 075 1010... 16 076 001 076 1010... 25 078 001 078 101
Mehrpreise für SonderausführungenModel 3233 3230SurchargeMeasuring ranges
abs. press.: 0...0,25 bar up to 0...10 barother
Electrical connectioneach additional m cable
Teflon cable, 1,5 m each additional m Teflon cable
Output signal 0 ... 20 mA 3-wire0 ... 5 V 3-wire0,5 ... 2,5 V 3-wire
Special versionslightening protection to IEC 801-5temperature meas. with Pt 100
Test certificate resp. DKD calibration certificate see page 112
Zubehör see chapter 12
filter element ZM51.001.003cable clip ZM51.001.002additional weight ZM51.001.001junction box IP54 ZM51.001.004
Order sample: model 3233 + code no. 075 001 = article no. 3233.075.001 1) up to 0 ... 0,16 bar: accuracy 0,5%Bold printed code no. ... delivery ex stock 2) power supply: 6...30 VDCother code no. ... note deliverytimes and minimum order value
Codeno
Codeno
Codeno
482,00460,00
auf Anfrage
96
Pressure Sensors for Food Industry
Model 3269
Accuracy 0.5Output 4...20 mA 0...10 VDCPower supply 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread Tri-Clamp DN 1 1/2"Case stainless steelPressure conn. stainless steelMedia temperature -20 ... +150°CProtection type IP65Datasheet DE726Measuring ranges Code Code
bar no noEUR/unit1 - 4 359,00 404,005 - 9 323,00 363,0010+ on request on request-1... 0 016 001 016 101-1... 3 044 001 044 101EUR/unit
1 - 4 314,00 359,005 - 9 282,70 323,0010+ on request on request
0... 0,25 065 001 065 1010... 0,4 066 001 066 1010... 0,60... 1 069 001 069 1010... 1,60... 2,5 072 001 072 1010... 4 073 001 073 1010... 6 074 001 074 1010... 10 075 001 075 1010... 16 076 001 076 1010... 25 078 001 078 101
Surcharges for special versionsModel 3269SurchargeMeasuring ranges other on requestAccuracy 0,25% from 0 ... 0,25 bar 39,40Electrical connection
connector M12x1, 4-pin, IP67 26,70cable output, 5 m, IP68 53,90
Output signal 0 ... 20 mA 3-wire see 4...20 mAother on request
Pressure conn.Tri-Clamp 2" 8,00union nut DIN 11851 with truncate cone DN25/40/50 on requestunion nut DIN 11864-1 with truncate flange form A DN40/50 on requestClamp ISO 2852 DN 33,7 / 38 / 40 / 51 on requestClamp DIN 32676 DN 25 / 32 / 40 / 50 on requestVarivent connection Form F / N on request
Sealing EPDM FDA approved 4,20other on request
Test certificate resp. DKD calibration certificate see page 112
Accessoires see chapter 12
junction box for M12x1 connector with 2 m cablestraight ZE53.011.010 10,40angled ZE53.011.011 10,40
Order sample: Model 3269 + code no. 080 001 = article no. 3269.078.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
97
Pressure Sensors for highest pressures
Model
Accuracy % 0.5Output 4...20 mA 0...10 VDCPower supply 10...30 VDC 14...30 VDCElectr. connection plug to DIN EN 175301-803 form A with junction boxThread M16x1,5 female 1)
Case stainless steel Pressure conn. stainless steel Media temperature -30 ... 100°CProtection type IP65Datasheet DE756Measuring ranges
bar
Surcharges for special versionsModelSurchargeMeasuring ranges
otherElectrical connection
round connector M12x1, 4-pincable oulet, 1 m
each additional m cableOutput signal 0 ... 20 mA 3-wire
0 ... 5 V 3-wirePressure connection 1/4-28 UNF LH max. 4000 bar
3/8-24 UNF LHM14x1,5 LH max. 5000 bar9/16-20 UNF max. 7000 bar
Test certificate resp. DKD calibration certificate
Additional informationto our products
is available under
www.tecsis.de
Order sample: model 3399 + code no. 091 001 = article no. 3399.091.001 1) from 0 ... 8000 bar: 3/8-24 UNF LHBold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
1288,00
Codeno
091 101
1160,00on request090 001
1333,001200,00
on request
093 001
3399
EUR/unit
EUR/unit
5 - 9
093 101
0...25000...4000
0…7000
1 - 4
1 - 45 - 9 10+
0…8000
0...50000...6000
10+
on request
056 001092 001
091 001056 101092 101
on request
Codeno
3399
510 101 1)
2272,002044,00
510 001 1)
2316,002084,00
090 101
98
Pressure Sensors for low and differential pressures
Model 3317
Accuracy 0.6Output 4...20 mA 0 ... 10 VDCPower supply 10 ... 30 VDC 15 ... 24 VDCElektr. Anschluß PG 7-screw for internal screw couplingElectr. connection 2 tube connectios for 4 mm tubeCase aluminiumMedia temperature -20 ... 70°CProtection type IP 65Datasheet AE 724Measuring ranges Code
mbar noEUR/unit
1 - 4 207,10 207,105 - 9 196,70 196,70
10+ 182,10 182,100... 2,5 055 001 055 1010... 5 915 001 915 1010... 10 058 001 058 101EUR/unit
1 - 4 173,20 173,205 - 9 164,80 164,80
10+ 152,90 152,900... 25 060 001 060 1010... 50 744 001 744 101EUR/unit
1 - 4 146,60 146,605 - 9 139,30 139,30
10+ 128,80 128,800... 100 063 001 063 1010... 250 065 001 065 1010... 500 187 001 187 1010... 1000 095 001 095 101
Order sample: model 3317 + code no. 065 001 = article no. 3317.065.001Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
99
Pressure Measuring Instruments
digital pressure gauge with local indication
Model 3960 2860
Accuracy % class 1,0 Display LCD-display, 4-digit analoge indication, NG100Output - 4...20 mAPower supply 9V mono block battery 10...30 VDCElectr. connection - junction box with screw joint PG 13,5Thread G 1/2 BCase plastic stainless steelPressure connection stainless steelMedia temperature -30 ... +85 °C -25 ... +100 °CProtection type IP65 IP54Datasheet DE 752 DE 728Measuring ranges Code Code
bar no noEUR/unit
1 - 4 164,30 315,005 - 9 148,10 283,7010+ on request on request
-1... 0 016 001 -0... 0,6 - 067 0010... 1 069 001 069 0010... 1,6 070 001 070 0010... 2,5 072 001 072 0010... 4 073 001 073 0010... 6 074 001 074 0010... 10 075 001 075 0010... 16 076 001 076 0010... 25 078 001 078 0010... 40 079 001 079 0010... 60 080 001 080 0010... 100 081 001 081 0010... 160 082 001 082 0010... 250 084 001 084 0010... 400 086 001 086 0010... 600 - 087 001
Surcharges for special versionsModel 3960 2860SurchargeAnaloge output
0 ... 20 mA 3-wire0 ... 2 VDC 2-wire
with plug M12x1, 5-pinwith cable outlet, 0,5m
Pressure connection G1/21/4 NPT1/2 NPT
Special versionspeak value memorylimit contcat 1) 1 NO
with plug M12x1, 5-pinwith cable outlet, 0,5m
oxygen, incl. free of oil and greasedamping (oil filling)front flange stainless steelblow out deviceorifice brass
stainless steelsurcharges for dials
Test certificate resp. DKD calibration certificate see page 112
Order sample: model 3960 + code no. 075 001 = article no. 3960.075.001 1) not available together with analog outputBold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
see page 40
0,5
stai
G 1/4 B
-
-none
100
Intelligent Pressure Measuring Instrument "DigiTrans"with internal diaphragm with front flush diaphragm
Model
Accuracy % 0,15%DisplayOutput 4...20 mAPower supply 12 ... 36 VDCElectr. connection cable screw coupling M20 x 1,5Thread G 1⁄2 B G 1⁄2 B front flush up to 1,6 bar G1BCase rotatable, made of highly restistant plastic (PBT)Press. connect. stainless steel stainless steel, NBR O-ring Media temperature -30 ... 105°CProtection type IP65Datasheet DE 750Measuring ranges Code Code Code Code
bar no no no noEUR/unit 1- 4 558,00 577,00 5- 9 447,00 462,00 10+-1... 0-1... 0,6-1... 3-1... 5-1... 15EUR/unit 1- 4 529,00 570,00 549,00 590,00 5- 9 423,00 456,00 439,00 471,00 10+0... 0,4 066 001 066 0010... 1,6 070 001 070 0010... 6 074 001 074 0010... 16 076 001 076 0010... 40 079 0010... 100 081 0010... 250 084 0010... 600 087 0010...1000EUR/unit 1- 4 5- 9 10+0...1600 1)
0...2500 1)
0...4000 1)
Surcharges for special versionsModel 3950 3951 3952 3953SurchargetPressure connect. 1⁄2 NPT
G 1 1⁄2 B front flush up to 0...16 barWetted parts Viton O-ring
Hastelloy C4 up to 0...16 barSpecial versions
free of oil and greaseoxygen; incl. Free of oil and greaseprotection type IP 67without 4-digit LCD-display reduction of price
Test certificate resp. DKD calibration certificate see page 112
Accessoires see chapter 12display, single ZE55.002.001Order sample: model 3950 + code no. 074 001 = article no. 3950.074.001 1) accuracy 0,5% only, max. turn down 2:1Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum order value
on request
074 001
absolute pressure3950 3951 3952
relative pressure relative pressure
088 001
076 001
087 001084 001081 001079 001076 001
070 001
3953
066 001on requeston request
074 001
absolute pressure
070 001066 001
on request
LCD display 4-digit
016 001 016 001on request on request
042 001 042 001044 001 044 001045 001 045 001049 001 049 001
1154,001048,00
091 001
on request089 001090 001
101
Electronic Pressure Switch "MagSwitch"with integrated LED
Model 3140
Switching output p - switching, adjustable on siteSwitching function 1)Power supply 10...30 VDCElectr. connection connector M12x1, 4-pinThread G1/4 BCase brass / plasticPressure connection brassMediatemperature -20 ... 80°CProtection type IP65Datasheet DE 740 / SE 781Adjustable range Code
bar noEUR/unit
1 - 910 - 24
25+ -0,1... -0,005 -0,16... -0,008 -0,25... -0,013 -0,4... -0,02 -0,6... -0,03 -0,9... -0,05EUR/unit
1 - 910 - 24
25+ 0,005... 0,1 0,008... 0,16 0,013... 0,25 0,02... 0,4 0,03... 0,6 0,05... 1 0,08... 1,6 0,13... 2,5 0,2... 4 0,3... 6 0,5... 10 1,6... 16 2,5... 25
Accessoires: see chapter 12Special versions: see page 103
Order sample: model 3140 + code no. 075 802 = article no. 3140.075.802 1) at increasing pressureBold printed code no. ... delivery ex stock 2) please specify switching point(s) by orderother code no. ... note deliverytimes and minimum order value
073 102074 102075 102
078 102076 602 076 802078 602 078 802
076 102
1 NO with adjustable hysteresis
065 102064 602 064 802 064 102065 602 065 802
2 NO 1 NO + 1 NC
012 102012 602 012 802013 602
015 102015 602 015 802
013 802 013 102014 602 014 802
46,40 46,40 48,4538,60 38,60 40,20
32,10 34,00011 602 011 802 011 10232,10
014 102
46,40 46,40 48,45
016 602 016 802 016 102
38,60 38,60 40,2032,10 32,10 34,00
063 602 063 802 063 102
066 602 066 802 066 102
MagSwitch with integrated pressure indication
Pressure switch with local indicationfor OEM applications
Pressure gauge ND50 with contact
072 602 072 802 072 102073 602 073 802074 602 074 802075 602
067 602 067 802 067 102
075 802
069 102070 102
069 602 069 802070 602 070 802
102
Electronic Pressure Switch "MagSwitch"with integrated LED Flangue version
Model
Switching output p - switching, adjustable on siteSwitching function 1)Power supply 10...30 VDCElectr. connection connector M12x1, 4-pinThread G1/4 B flangue 40x40 mmCase aluminium anodized / plasticPressure connection brassMediatemperature -20 ... 80°CProtection type IP65Datasheet DE 740 / SE 781Adjustable range Code
bar noEUR/unit
1 - 910 - 24
25+ 3... 60 5... 100 8... 16013... 25020... 40030... 600
Surcharges for special versionsModel 3140 3141SurchargeAdjustable range otherElectr. Connection cable outlet, 2 m, IP67
other cable lengthsSwitching outout 1 NC
1 NO2 NC
Pressure connection G1/8G1/2, 1/2 NPTG1/4 female1/4 NPT, M10x1, M12x1,5
Special verionsoxygen incl. Free of oil and greasewith integrated indication
Adjustment of switching points 2) per switching output
Accessoiresjunction box for M12x1 connector with 2m cable
straight ZE53.011.010angled ZE53.011.011
Order sample: model 3141 + code no. 084 802 = article no. 3141.084.802 1) at increasing pressureBold printed code no. ... delivery ex stock 2) please specify switching point(s) by orderother code no. ... note deliverytimes and minimum order value
087 602 087 802 087 102 087 803086 602 086 802 086 102 086 803084 602 084 802 084 102 084 803082 602 082 802 082 102 082 803081 602 081 802 081 102 081 803080 602 080 802 080 102 080 80346,90 46,90 48,45 53,0051,60 51,60 53,35 58,3564,70 64,70 66,70 73,10
3141
2 NO 1 NO + 1 NC 1 NO w. adjust. hyst. 1 NO + 1 NC
103
Mechanical Pressure Switches
MiniatureModel 3150 3151 3152 3153 3154 3155 3156
Switching output 1 switching output, adjustable on siteSwitching element contact, silver platedSwitching function NC NO NC NO SPDT SPDT SPDTElectr. Connection push on terminals 2 x 6,3x0,8 push on terminals 3 x 6,3x0,8 connectorThread G 1/8 B G 1/4 B G 1/8 B G 1/4 BCase brass zinc-plated steel brass zinc-plated steelSealing element NBR from 10...70 bar PUR NBRMedia temperature -25 ... 85 °CDatasheet DE 745 / SE 781 DE 746 / SE 781 SE 781Adjustable range Code Code Code Code Code Code Code
bar no no no no no no noEUR/unit
25+ 6,80 6,80 8,20 8,20 18,70 17,80 16,50-0,8... -0,02 114 001 0,3... 2 071 001 071 001 071 001 0,2... 2,5 072 001 1... 10 075 002 075 002 075 001 075 001 075 001 1... 12 110 001EUR/unit
25+ 8,95 8,95 11,10 11,10 20,30 17,80 5... 50 785 001 10... 70 127 002 127 002 127 001 127 001 127 001 10... 100 081 001 20... 200 083 001 50... 200 083 001 083 001 083 001EUR/unit
25+ 20,90 50... 400 086 001
Surcharges for special versions3150
Model 3151 3152 3153 3154 3155 3156Adjustment of switching point 1)
Accessoires see chapter 12Protection cap ZM90.101.001
ZM90.101.002
Order sample: model 3150 + code no. 075 002 = article no. 3150.075.002 1) please specify by orderBold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
with plug DIN EN
175301-803with push on terminals
104
Mechanical Pressure Switches
with rotatable case manifold style for differential pressureModel 3160 3161 3165 3166 3170 3171 3172
Switching output 1 switching output, adjustable on siteSwitching element silver-plated contactSwitching function SPDTElectr. connection plug to DIN EN 175301-803 with junction box Thread G 1/4 B 2 x G 1/8 femaleCase zinc-plated steel Al / brass Al zinc-plated steel brass zinc-plated steelMeasuring element diaphragm, from 10 ... 70 bar piston diaphragm pistonSealing element NBR from 10...70 bar PUR NBR PURMedia temperature -25 ... 85°CDatasheet DE 747 / SE 781 DE 748 / SE 781 on requestAdjustable range Code Code Code Code Code Code Code
bar no no no no no no noEUR/unit 25+ 25,20 43,50 30,50 35,30 48,40 63,70 72,30-0,8... -0,02 114 001 0,3... 2 071 001 071 001 071 001 0,5... 3 113 001 0,3... 6 074 001 1... 10 075 001 075 001 2... 10 075 001 1... 16 076 001 5... 50 785 001EUR/unit 25+ 27,45 37,70 10... 70 127 001 127 001 50... 200 083 001 083 001EUR/unit 25+ 44,40 50... 400 086 001
Surcharges for special versions31703171
Model 3160 3161 3165 3166 3172Surcharge EUR/unitAdjustment of switching point 1)
Accessoires see chapter 12
Additional informationto our products
is available under
www.tecsis.de
Order sample: model 3160 + code no. 075 001 = article no. 3160.075.001 1) please specify by orderBold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
G 1/4 female or flange mounting 1)
105
Electronic pressure switch with internal diaphragm with front flush diaphragm
Model 3131 3132
Switching output switching point(s) optional factory set or adjustable on site via programming setp - switching n - switching p - switching n - switching
Number of outputs 2Switching function NC, NO or switching windowPower supply 10...30 VDCElectr. Connection round connector M12x1, 5-pinThread G 1⁄2 B G 1⁄2 B front flush up to 0 ... 1,6 bar G1BCase stainless steelPress. connection stainless steel stainless steel, NBR O-ringMedia temperature -30 ... 100°CDatasheet DE 739 / SE 781Adjustable range Code Code Code Code
bar no no no noEUR/unit
1 - 9 174,70 174,70 213,10 213,1010 - 19 139,80 139,80 170,50 170,50
20+ on request on request on request on request0... 0,25 065 402 065 602 065 402 065 6020... 0,4 066 402 066 602 066 402 066 6020... 0,6 067 402 067 602 067 402 067 6020... 1 069 402 069 602 069 402 069 6020... 1,6 070 402 070 602 070 402 070 6020... 2,5 072 402 072 602 072 402 072 6020... 4 073 402 073 602 073 402 073 6020... 6 074 402 074 602 074 402 074 6020... 10 075 402 075 602 075 402 075 6020... 16 076 402 076 602 076 402 076 6020... 25 078 402 078 602 078 402 078 6020... 40 079 402 079 602 079 402 079 6020... 60 080 402 080 602 080 402 080 6020... 100 081 402 081 602 081 402 081 6020... 160 082 402 082 602 082 402 082 6020... 250 084 402 084 602 084 402 084 6020... 400 086 402 086 602 086 402 086 6020... 600 087 402 087 602 087 402 087 6020...1000 088 402 088 602
Surcharges for special versionsModel 3131 3132 3133 3134SurchargeAdjustable range absolute pressure
vacuum and compound rangesother
Electr. Connection cable outlet, 1 m, IP67 each additional m cable
Pressure connection G 1⁄4 B; 1⁄4 NPT; 1⁄2 NPTWetted parts Hastelloy C4
PFA coating Media temperature -40 ... 125 °C Special versions free of oil and grease
oxygen; front flush up to 0...160 bar
Accessoires see chapter 12Weld-on adapter G 1 B ZM23.031.004for front flush diaphragm G 1/2 B ZM23.031.006Programming set 1) for M12x1 connector ZE53.080.014
for DIN plug ZE53.080.017Net adapter Euro-Norm ZE53.080.004
Order sample: Model 3131 + code no. 075 402 = article no. 3131.075.402Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
106
Electronic pressure switch with digital displayswitch points programmable on site
Model
Analog outputSwitching outputsSwitching function NC, NO, switching window; hysteresis programmable; output 2 programmable for failure indicationPower supply 15...30 VDC
Electr. Connection
Thread G 1/4 B acc. to DIN 3852-ECase zinc diecastPress. connection stainless steelMeas. principle thin film, <25 bar ceramic with NBR sealingProtection type IP65 IP67Datasheet SE 781Adjustable range Code Code Code Code
bar no no no noEUR/unit
1 - 910 - 19ab 20 on request on request on request on request
-1... 2,5 072 001 072 403 072 003 072 402 -1... 4 073 001 073 403 073 003 073 402 -1... 6 074 001 074 403 074 003 074 402 -1... 10 075 001 075 403 075 003 075 402 -1... 16 076 001 076 403 076 003 076 402 0... 25 078 001 078 403 078 003 078 402 0... 40 079 001 079 403 079 003 079 402 0... 60 080 001 080 403 080 003 080 402 0... 100 081 001 081 403 081 003 081 402 0... 160 082 001 082 403 082 003 082 402 0... 250 084 001 084 403 084 003 084 402 0... 400 086 001 086 403 086 003 086 402 0... 600 088 001 088 403 088 003 088 402
Surcharges for special versionsModelSurchargeAdjustable range otherPressure connection G 1/2 B
G 1/4 femaleWetted parts other O-ring material for ceramic cell on request
Accessoires: see chapter 12
Order sample: Model 3135 + code no. 075 403 = article no. 3131.075.403Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
217,40
nonenone
none none 0 (4) .. 20 mA 0 (4) .. 20 mA1 x p-switching 2 x p-switching
connector DIN EN 175301-803
round connector M12x1, 4-polig
round connector M12x1, 4-polig
round connector M12x1, 5-polig
1 x p-switching 2 x p-switching
3135 3136
3135 3136
247,80184,80 184,80 210,60 210,60
107
Attachable Digital Indicators with MicroprocessorIndicator
Model 1999.100.001
Digital indication LCD 4 - digit LED 4 - digit LED 5 - digitLimit contacts none 2 transistor outputs, 2 transistor outputs, n-switching
n-switching 1 relay, changeover contactDisplay accuracy ± 0,2 % ± 1 digit ± 0,2 % ± 1 digit ± 0,01 % ± 1 digitRange adjustment freely programmable freely programmable freely scalable by means of
up to 10 scaling pointsOffset - - programmableSensor signal 4 ... 20 mA selectable: selectable:
0...20 mA, 4...20 mA, 0...20 mA, 4...20 mA,0...1 V, 0...10 VPt100 ( 3-wire )Pt1000 ( 2-wire ) 0... 5 V, 0...10 V, +/- 10 V
Number of chanels 1 1 1Sensor supply - - 24 VDCAnaloge output - - optionValue memory - -Mains supply from loop cuorrent 9 ... 28 VDC 90 ... 264 VACCase 48,5 x 48,5 x 35,5 for panel mounting 48 x 24 for panel mounting 96 x 48 Protection type (front side) IP 65 IP 54 IP 66Electr. Connection adapter for junction box plug-in screw terminals screw terminals on the
to DIN 43650 caseDatasheet DE 733 DE 733 DE 744EUR/Stück 114,20
Surcharges for optionsModel 1999.100.xxx 1999.500.xxxSurcharge EUR/unitdigital interface RS 485 1)
Programming tocustomers requirementsprotection type IP65 front sideMains supply 20...50 VAC
22...55 VDC110 VAC24 VDC see 22...55 VDC
Analogue outputLimit contacts second relayDigital interface 1)
Additional informationto our products
is available under
www.tecsis.de
Order sample: Model 1929.300.001 1) The combination digital inteface and RS485 is not feasible.Bold printed code no. ... delivery ex stockother code no. ... note delivery times and minimum order value
1929.300.001
19,60
1999.500.001 1929.300.001
99,50 229,50
peak value memory (MAX and MIN)
55,30
- on request 55,30
33,90
-
-
-
--
19,60 19,60
6,40-
-
-
-
--
33,90
-
-
Standard
62,6044,40
108
Hand-held Pressure Measuring Instrument "Manoport"
Model 3922 3923
Accuracy ±0,2 % of F.S. ± 1 digit ±0,6 % of F.S. ± 1 digit 1)repeatability ±0,1 % of F.S. ±0,1 % of. F.S. 2)Display 7-segment LCD-dispaly, 4 digit 7-segment LCD-display; 3 1⁄2 digitPressure type differential pressure (contains negative and positive gauge pressur)Overload limit 3 -times; max. 13 bar 3 -times 3)Media dry, non-aggressive gasesPressure connection G1/8 female 2 couplings for 4mm tubesOperation temperature 0 .... 50 °CTemperature influence: up to 0 ... 5 mbar: 2,5%
zero point 0,1 % / 10 K > 5 mbar: 1% span 0,1 % / 10 K > 100 mbar: 0,7%
Zero point adjustment programmable via turning screwPower suppply 9 V mono-block batteryCase plastic gray; 175 x 80 x 30 plastic black; 170 x 84 x 30Protection type IP 67 IP 54Delivery contents hand-held incl. battery with 2 hand-held incl. battery
tubes and 2 tube couplingsDatasheet DE 737 DE 735
10+ on requestMeasuring range diff. pressure Code Code Code
mbar no. no. no.0 ... 2,5 - 055 001 -0 ... 5 - - 553 0010 ... 10 - - 058 0010 ... 25 - - 060 0010 ... 50 - - 7440010 ... 100 - - 0630010 ... 140 425 001 - -0 ... 250 - - 065 0010 ... 350 362 001 - -0 ... 500 - - 187 0010 ... 1000 - - 095 0010 ... 2000 366 001 - -0 ... 6900 368 001 - -
Surcharges for options and accessoires 3922 3923article no.
pressure connection with silicon protection for fluids -Rubber protection cap CZ60.000.001Carrying case, plastic ZM49.090.016Carrying case, plastic ZM49.090.017Tube quick coupling for tube 4 mm ZM25.001.001
for tube 6 mm ZM25.001.002for tube 8 mm ZM25.001.003
Recommended basic equipementHand-heldCarrying case
Order sample: model 3922 + code no. 425 001 = article no. 3922.425.001 1) up to 0 ... 100 mbar: accuracy 1% of F.S.Bold printed code no. ... delivery ex stock 2) up to 0 ... 10 mbar: repeatability 0,3 % of F.S.other code no. ... note deliverytimes and minimum order value 3) up to 0 ... 100 mbar: over load limit 11 -times
109
Hand-held Pressure Measuring Instrument "Manoport"
Model 3904.500.001
digital instrument forexternal pressure transmitterModel 3392
Accuracy ±0,2 % of F.S. ± 1 digit Case plastic black; 175 x 80 x 30Display 7-segment LCD-display, 10,2 mm high, selectable (e.g. bar, mbar, psi ...)Range of Display -1999 .. 9999 digitPressure type depending on sensor usedOverload limit depending on sensor usedMedia depending on sensor usedPressure connection depending on sensor usedSensor connections plug with locking deviceOutput -Power suppply 9 V mono-block batteryDelivery contents hand-held incl. batteryWeightt measuring instrument approx. 0,16kgDatasheet AE 763EUR/unit
Surcharges for options and accessoiresModel 3904.500Surcharge EUR/unitConnection cable for pressure transmitter ZE53.001.005Differential pressurePlastic service case for 1 digital instrument, 3 pressure transmitter, 9V batteryAluminium case for 1 digital instrument, 3 pressure transmitter, pneumatic hand pumpAluminium case for 1 digital instrument, 3 pressure transmitter, hydraulic spindel pumpAluminium case for 2 digital instr., 3 press. transm., power supply unit and accu charger9 V battery9V Accu9V Accu chargerPower suplly unitHand pump, pneumatic -800 mbar ... 25barSpindel pump, hydraulic: up to 250 barSpindel pump, hydraulic: up to 1000 barHose, 1m with 2 adapter G 1/2 (max. 400 bar)Hydraulic oil storage bin 0,3 l incl. shut off value up to max. 400 barHydraulic oil storage bin 0,3 l incl. shut off value up to max. 1000 barSystem "Minimess" G 1/2A; connection for process PN 400, steel coatedSystem "Minimess" G 1/2A; connection for pressure Transmitter PN 400, steel coatedSystem "Minimess" G 1/2A; connection for process PN 630, steel coatedSystem "Minimess" G 1/2A; connection for pressure Transmitter PN 630, steel coatedData logger evaluation software included adapter for RS232
Recommended basic equipmentModel 3904.500.001:service casedigital instrument, connection cable for pressure transmitter
Order sample: model 3904.500.001 1) model 3392 see page 111Bold printed code no. ... delivery ex stockother code no. ... note deliverytimes and minimum oder value
208,53
110
External Pressure Sensors for Hand-held Pressure Instrumentwith internal diaphragm
Model 3392
AccuracyOutput special for Hand-held instrumentPower suppply supplied by Hand-held instrumentElectr. connection special-connector for Hand-held instrumentThreadCase stainless steelPressure connection stainless steelMedia Temperatur -25 ... 70°CProtection type IP 65Datasheet AE 763Measuring ranges
barEUR/unit
0... 0,10... 0,160... 0,250... 0,40... 0,60... 10... 1,60... 2,50... 40... 60... 100... 160... 250... 40EUR/unit
0... 600... 1000... 1600... 2500... 4000... 600EUR/unit
0... 1000EUR/unit
0... 16000... 25000... 4000
Surcharges for options and accessoiresModelSurcharge EUR/unitMeasuring ranges other
absolute pressurePressure connect. G 1⁄4 B; 1⁄4 NPT; 1⁄2 NPT
front flush diaphragmSpecial version
oxygen clean, incl. Free of oil and grease
Order sample: model 3392 + code no. 075.501 = article no. 3392.075.501Bold printed code no. ...delivery ex stockother code no. ...note deliverytimes and minimum oder value
±0,2 % of F.S. ± 1 digit
319,00063 501064 501
Codeno
on request
on requeston requeston request
auf Anfrage089 501090 501091 501
084 501086 501087 501
088 501
076 501
080 501081 501082 501
066 501
on request
069 501070 501072 501073 501
349,00
074 501075 501
G 1⁄2 B from 0 ... 2500 bar M 16 x 1,5 (female)
3392
078 501079 501
389,00
067 501
065 501
111
Test certificates for sensors
DKD-calibration certificate
> 0,6 0,6...0,1 < 0,1(5 check points) (10 check points)
gauge press. between -400 mbar ... +400 mbar 195,00 245,00between -1 ... 25 bar 105,30 161,60
0....1600 bar 122,70 211,700....2500 bar 368,00 458,000....4000 bar 516,00 608,000....6000 bar 557,00 649,00
0....10000 bar 695,00 813,00absolute pressure 140,60 245,40
Test certificate according to DIN 55350 part 18 4.1.2
> 0,6 0,6...0,1 < 0,1(5 check points) (10 check points)
gauge press. between -400 mbar ... +400 mbar 115,00 154,00between -1 ... 25 bar 51,10 64,40
0....1600 bar 60,30 98,400....2500 bar 265,90 296,500....4000 bar 399,00 429,000....6000 bar 419,00 450,00
0....10000 bar 465,00 506,00absolute pressure 70,60 98,20
on request
The calibration is carried out according to DIN 55 350 part 18 incl. the measured values and indication of the used test standard.
Accuracy class in percent of the span value
The certification is done via a manufacturer certificate.
Measuirng range
Accuracy class in percent of the span value
net-price EUR
The calibration is carried out according to the regulations of DKD incl. the measured values, a tracable national standard and calculation of the total measuring error.The certification is done via a DKD-calibration certificate. The object of calibration is make with a calibration sign and a test badge, containing the test date and the the date for the next test.
net-price EUR
on request
Measuirng range
112
Technologies for Sensors Indicators and Systems Pressure Temperature Force
model: Models: 3245, 3248, 3272, 3276, 3277, 3376, 3377tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 700e
p. 1/4
Pressure Sensors for general Applicationwith internal diaphragmfor gauge pressure and absolute pressure
accuracy 0.25% and 0.5 %
standard output: 4...20 mA; 2-wire system or 0...5 VDC; 3-wire system or 0...10 VDC; 3-wire system
Description
Pressure sensors for general application are topof the range pressure transducers.
Their accuracy, reliability, resistance to corrosionand mechanical load make them suitable for allpressure measuring tasks - in production,development or in the laboratory.
The measuring ranges, graded in accordancewith EN, range from 25 mbar to the maximumpressure range of 4000 bar. The case and wettedparts comprise stainless steel and are thusresistant to chemically aggressive media. Thepressure connection and measuring element arewelded together, making the measuring systemparticularly resistant to mechanical shock orvibration.
For more difficult measuring tasks (e.g. hydro-static column), two potentiometers enable thezero point and measuring range to be set.
The pressure sensors for general applicationmeet the electronic magnetic compatibility(EMC) requirements to EN 61326.
Features
O Measuring ranges from 25 mbar to 2500 bar
O Finely graded selection of nominal pressureranges according to EN
O Corrosion resistant, stainless steel designO High overload protectionO Highly resistant to shock and vibrationO For dynamic or static measurementsO Good reproducibilityO Simple installation
Measuring ranges
Gauge pressurenegative -1...0 bar to -0.025...0 barpositive 0...0.025 bar to 0...2500 barAbsolute pressure 0...0.25 bar to 0...16 bar
Applications
Development and laboratory,Process engineering,Plant and apparatus construction,Hydraulics and pneumatics.
DE 711
p. 2/4
Technical data
Model 3276 3277 3376 3377 3245 3248 OptionPressure type negative or positive gauge pressure absolute
pressurenegative and positivegauge pressure
Output signal 4...20 mA - 2-wire system0...5 VDC - 3-wire system0...10 VDC - 3-wire system
0..20 mA - 3-wire systemother signals on request
Accuracy % of F.S. 1) 0.5 0.25 0.5 0.25 0.5 0.25Ranges accord. to EN 0 ... 0.1 bar 2)
to0 ... 16 bar
0 ... 25 barto
0 ... 2500 bar
0 ... 0.25 barto
0 ... 16 bar
0...25 mbar 3)0...40 mbar0...60 mbar
Sensor element piezoresistive Thin film piezoresistiveRepeatability ≤ ± 0.05 % of F.S.Stability (annual) ≤ ± 0.2 % of F.S. in rated conditionsCase stainless steelPressure connection 4) G 1⁄2 B to DIN 16288 G1⁄4B; 1⁄4NPT; 1⁄2NPTWetted parts stainless steel 1.4571 and 1.4542Overload limit ≤16 bar 3.5 x ; ≤600 bar 2 x; >600 bar 1.5 x;
≥1600 bar 1.2 x ;Electrical connection plug according to DIN 43650 with junction box
round connetctor M12x1; 4-pincable outletwith 1 m cable
Power supply 10...30 VDC (14...30 VDC for output 0...10 V)Power consumption current output 4...20 mA: signal currency
current output 0...20 mA: signal currency + 4 mAvoltage output: 8 mA
Load
A0.020 V12-UB≤ for output (0)4...20 mA
> 5 kOhm for output 0...5 V> 10 kOhm for output 0...10 V
Temp.compens. range 0....80°CTemperature influence− Zero point− Measuring range
± 0.2 % /10 K 5)± 0.2 % /10 K
Adjustability zero point and full scale up to ± 10 %Response time ≤ 1 ms (within 10 % to 90 % of F.S.)Protection type IP 65 to EN 60529/IEC 529
IP 67 for M12x1 connectorIP 67 for cable outlet
Emission 6) according to EN 61326Interference 6) according to EN 61326Electrical protection types polarity, overload and short-circuit protectionTemperature ranges− Storage− Medium− Ambient
-40 .... 100 °C-30 .... 100 °C-20 .... 80 °C
media temperature-40 ... 125 °C
Weight approx. 0.2 kgof F.S.= of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis2) 0.25% accuracy for ranges ≥ 0.25 bar3) For ranges < 0.1 bar: model 3275; technical data as model 3276;
wetted parts 1.4571, Si, Al and Au; only applicable for dry and non agressive gases4) ≥ 0 ... 2500; bar M16 x 1.5 female5) ≤ ± 0.4 % / 10K for measuring ranges 0...0.1 and 0...0.16 bar6) Declaration of conformity on request
DE 711
p. 3/4
Dimensions (mm)
CasePlug according to DIN 43 650
Accuracy 0,5% Accuracy 0,25% cable outlet
82
54
48
27
max
. 105
75
48
27
27
Pressure connections
G 1/2 B G 1⁄4 B High pressure connectionM16x1.5 female
A-006
G1/2
6
17,5
3
320
27
22
13
59,5
G1/4
27
A-007
19.5
124,8
60°
M16 x 1,5
26.5
27
A-020
Screw-in aperture according to DIN 16288
G 1⁄2 G 1⁄4 High pressure connectionM16x1.5 female
24,5
+1
19-0
,5
Min
. 14.
5
7
G1/2(DIN 16288)
A0.1
A
S-001
G1/4
5,5
16,5
+1
13-0
,5
Min
.9,5
A0.1
A
S-002
M16X1.560°
4.8
S-008
DE 711
p. 4/4
Electrical connection
Two-wire systemDIN 43 650 plug MIL-plug PT 02 E-10 6P 5-pin plug
UB / S+
0V / S-
13
2
E-001
UB / S+
0V / S-
AE CD
BF
E-011
UB / S+
0V / S-
1
24 3
5
E-035
cable outlet M12x1UB / S+
0V / S-
brown
green
E-016
UB / S+
0V / S-
1 24 3
E-033
Three-wire system
DIN 43 650 plug MIL-plug PT 02 E-10 6P 5-pin plugUB
0V / S-
S+
E-002
UB / S+
0V / S-
A
E CDBF
E-012
UB
0V / S-
1
24 3
5
S+
E-036
cable outlet M12x1
0V / S-
UB
S+
brown
green
white
E-018
UB
0V / S-
S+
41
32
E-034
Connection table for DIN plug or cable outlet4...20 mA(2 - wire)
0...10VDC(3 - wire)
Supply: UB+ 1 brown 1 brownSupply: OV 2 green 2 greenSignal: S+ - - 3 whiteSignal: S- - - 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
Technologies for Sensors Indicators and Systems | pressure | temperature | force
tecsis GmbHCarl-Legien-Str. 40D-63073 Offenbach / Main Sales Inland Export Sales E-Mail [email protected]. +49 (0) 69 / 58 06-0 Fax +49 (0) 69 / 58 06-1 70 Fax +49 (0) 69 / 58 06-1 77 Internet www.tecsis.de
Pressure Sensors for general Applicationwith front flush diaphragmfor gauge pressure and absolute pressure
Accuracy 0.25% and 0.5%
Standard output: 4 . . . 20 mA; 2-wire systemor 0 . . . 5 VDC; 3-wire systemor 0 . . . 10 VDC; 3-wire system
Description
Pressure sensors for general Application are top of therange pressure transducers.
Their accuracy, reliability, resistance to corrosion and me-chanical load rating make them suitable for all pressuremeasuring tasks - in production, development or in the la-boratory.
The front flush pressure diaphragm avoids zones, inwhich medium could crystallize or residues could form,thus ensuring trouble-free pressure measurement andhygienic cleaning of the pressure sensors.
The measuring ranges, graded in accordance with EN,range from 0.1 bar to 600 bar. The case and wetted partscomprise stainless steel and are thus resistant to chemi-cally aggressive media. With the aid of an integrated coo-ling element, the sensors can be supplied with mediumtemperatures up to 150 °C.
For more difficult measuring tasks (e.g. hydrostatic co-lumn), two potentiometers enable the zero point andmeasuring range to be set.
The pressure sensors for general Application meet theelectronic magnetic compatibility (EMC) requirements toEN 61 326.
Features
For pasty or crystallizing media
Finely graded selection of nominal pressureranges according to EN
Corrosion resistant stainless steel design
High overload protection
Highly resistant to shock and vibration
For dynamic or static measurements
Good repeatability
Integrated cooling element for mediumtemperatures up to 150 °C
Measuring ranges
Gauge pressurenegative -1 . . . 0 bar to -0.1 . . . 0 barpositive 0 . . . 0.01 bar to 0 . . . 600 barAbsolute pressure 0 . . . 0.25 bar to 0 . . . 16 bar
Application
Process engineering,Plant and apparatus design,Development and laboratory applications
DE 7 01 d
P. 1 / 4
Models: 3251, 3252, 3255, 3256, 3344, 3386
DE 7 01 d
P. 2 /4
Technical data
ModelPressure type
Output signal
Accuracy % of F. S. 1)Ranges accord. to EN
Sensor elementRepeatabilityStability (annual)CasePressure connectionWetted partsOverload limitElectrical connection
Power supplyPower consumption
Load
Temp. compens. rangeTemperature influence
- Zero point- Measuring range
AdjustabilityResponse timeProtection typeEmission 4)Interference 4)Electrical protection typesTemperature ranges
- Storage- Medium- Ambient
Weight
negative or positive gauge pressure absolutepressure
4 . . . 20 mA - 2-wire system0 . . . 5 VDC - 3-wire system0 . . . 10 VDC - 3-wire system
0.5 0.25 0.5 0.25 0.5 0.250 . . . 0.1 bar 2) 0 . . . 25 bar 0 . . . 0.25 barto to to0 . . . 16 bar 0 . . . 600 bar 0 . . . 16 barpiezoresistive thin film piezoresistive≤ ± 0.05% of F. S.≤ ± 0.2% of F. S. in rated conditionsStainless steel ≤ 0 . . . 1.6 bar G 1 B; ≥ 0 . . . 2.5 bar G 1/2 BStainless steel 1.4571≤ 16 bar 3.5 x; ≤ 600 bar 2 x; vacuum resistantPlug to DIN 43 650 with junction boxRound connector M12x1, 4-pin10 . . . 30 VDC (14 . . . 30 VDC for output 0 . . . 10 V)output 4 . . . 20 mA: signal currentoutput 0 . . . 20 mA: signal currency + 4 mAvoltage output: 8 mA
≤UB - 12 V for output 4(0) . . . 20 mA0.020 A
> 5 kOhm for output 0 . . . 5 V> 10 kOhm for output 0 . . . 10 V0 . . . 80 °C
± 0.2%/10 K 3)± 0.2%/10 Kzero point and measuring range up to ± 10%≤ 1 ms (within 10% to 90% of F. S.)IP 65 to EN 50 629/ IEC 529to EN 61 326to EN 61 326polarity-, overload- and short-circuit-protection
-40 . . . 100 °C-30 . . . 100 °C-20 . . . 80 °C
approx. 0.2 kg
Optionnegative and positivegauge pressure0 . . . 20 mA; 3-wire system; other signalson request
cable outlet with1 m cable
IP 67 for cable outlet
Medium temperature-40 . . . 125 °C
integrated coolingelement for temperaturesup to 150 °C
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis of F. S. = of full scale value2) 0.25% accuracy only for ranges ≥ 0.25 bar3) ≤ ± 0.4% / 10 K for measuring ranges 0 . . . 0.1 and 0 . . . 0.16 bar4) Declaration of conformity on request
3251 3252 3386 3344 3255 3256
DE 7 01 d
P. 3 / 4
Dimensions (mm)
CasePlug according to DIN 43 650
Accuracy 0.5% Accuracy 0.25% with integrated cooling element cable outlet
Pressure connections
G 1/2 B G 1 B
Weld-on socket or screw-in aperture
G 1/2 G 1
* for long version + 22 mm
tecsis GmbHCarl-Legien-Str. 40D-63073 Offenbach / Main Sales Inland Export Sales E-Mail [email protected]. +49 (0) 69 / 58 06-0 Fax +49 (0) 69 / 58 06-1 70 Fax +49 (0) 69 / 58 06-1 77 Internet www.tecsis.de
Modifications reserved
4 . . . 20 mA(2-wire)
1 brown2 green-- ---- --
0 . . . 10 VDC(3-wire)
1 brown2 green3 white2 green
Supply: UB+Supply: 0VSignal: S+Signal: S-
Connection table for DIN plug or cable outletOrder details1. Model2. Measuring range3. Output signal4. Options
DE 7 01 d
P. 4 / 4
Subject to technical changes
Electrical connection
Two-wire systemDIN 43 650 plug MIL-plug PT 02 E-10 6P 5-pin plug
cable outlet M12x1
Three-wire systemDIN 43 650 plug MIL-plug PT 02 E-10 6P 5-pin plug
cable outlet M12x1
brown
green
brown
white
green
DE 705 c Models: 3247, 3249, 3349page 1/4
Pressure Sensors Compactwith internal diaphragmfor gauge pressure and absolute pressure
accuracy 0.5 %
standard output: 4...20 mA; 2-wire system or 0...5 VDC; 3-wire system or 0...10 VDC; 3-wire system
Description
Pressure sensors Compact are top of the rangepressure sensors.
Compact, sturdy, accurate and long-term stable,they perform industrial pressure measuring jobsreliable in the fields of production anddevelopment and in the laboratory.
The compact design with G 1⁄4 B pressureconnection enables space-saving and low-weightinstallation. The materials and technology usedmake these pressure sensors insensitive tochemically aggressive media and mechanicalload.
Measuring ranges from 250 mbar up to 1000 bar,graded in accordance with EN, offer a widerange of possible applications. The overload limitup to 16 bar is 3.5-fold, between 16 and 600 bar2-fold and above 600 bar 1.5-fold.
The short response time of the pressure sensorsof < 1ms enables peak pressures with frequen-cies of up to 150 Hz to be measured. DIN plugsor cable outlets are used to pick up the electricaloutput signals.
The Compact pressure sensors meet theelectromagnetic compatibility (EMC) to EN61326.
Features
O Compact design
O Pressure connection G1⁄4B
O High peak pressure resistance
O High alternating load resistance
O High long-term stabilityO Corrosion resistant stainless steel designO For dynamic and static measurements
Measuring ranges
gauge pressurenegative -1...0 bar to -0.25...0 barpositive 0...0.25 bar to 0...1000 barabsolute pressure 0...0.25 bar to 0...16 bar
Applications
Process engineering,Hydraulics and pneumatics,Conveyor and lifting systems,General mechanical engineering,Development and laboratory applications.
DE 705 cpage 2/4
Technical data
Model 3249 3349 3247 OptionsPressure type negative or positive gauge pressure absolute
pressurenegative and positivegauge pressure
Output signal 4...20 mA - 2-wire system0...5 VDC - 3-wire system0...10 VDC - 3-wire system
0...20 mA - 3-wire systemother siganls on request
Accuracy ± 0.5 % of F.S. 1)Ranges accord. to EN 0 ... 0.25 bar
to0 ... 16 bar
0 ... 25 barto
0 ... 1000 bar
0 ... 0.25 barto
0 ... 16 bar
other measuring rangeson request
Sensor element piezoresistive thin film piezoresistiveRepeatability ≤ ± 0.05 % of F.S.Stability (annual) ≤ ± 0.2 % of F.S. in rated conditionsCase stainless steelPressure connection G 1⁄4 B to DIN 16288 other pressure connections
on requestWetted parts stainless steel 1.4571 and 1.4542Overload limit ≤ 16 bar 3.5-fold; ≤ 600 bar 2-fold; > 600 bar 1.5-fold;
vacuum resistantElectrical connection plug according to DIN 43650C with junction box cable outlet with1 m cablePower supply 10....30 VDC (14...30 VDC for output 0...10 V)Power consumption output 4...20 mA: signal current
output 0...20 mA: signal current + 4 mAvoltage output: 8 mA
Load
0.020A10VUB −≤ for output 4(0)...20 mA
> 5 kOhm for output 0...5 V> 10 kOhm for output 0...10 V
Temp. compens. range 0.... 80°CTemperature influence ± 0.3 % /10 K, on zero point and measuring rangeAdjustability on zero point and measuring range ± 10 %Response time ≤ 1 ms (within 10 % to 90 % of F.S.)Protection type IP 65 EN 60529 / IEC 529 IP 67 for cable outletEmission 2) To EN 61326Interference 2) To EN 61326Electrical protection types polarity, overvoltage and short-circuit protectionTemperature ranges− Storage− Media− Ambient
-40 .... 100 °C-30 .... 100 °C-30 .... 85 °C
Weight approx. 0.10 kgof F.S.= of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis2) Declaration of conformity on request
DE 705 cpage 3/4
Dimensions (mm)
Caseplug according to DIN 43 650C cable outlet
G1/4B17
1580
106
27 27
17
80
130
G1/4B
Screw-in aperture according to DIN 16288
G1/4
5,5
16,5
+1
13-0
,5
Min
.9,5
A0.1
A
S-002
DE 705 cpage 4/4
Electrical connection
Two-wire system
DIN 43 650 C plug cable outletUB / S+
0V / S-
1
3 2
E-005
UB / S+
0V / S-
brown
green
E-016
Three-wire system
DIN 43 650 C plug cable outletUB
0V / S-
S+
E-006
0V / S-
UB
S+
brown
green
white
E-018
Connection table for DIN plug or cable outlet4...20 mA(2 - wire)
0...10VDC(3 - wire)
Supply: UB 1 brown 1 brownSupply: 0V 2 green 2 greenSignal: S+ - - 3 whiteSignal: S- - - 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
DE 706 e Models: 3272, 3373page 1/4
Pressure Sensors Compactwith internal diaphragm
accuracy 1 %
standard output: 4...20 mA; 2-wire system or 0...10 VDC; 3-wire system
Description
The pressure sensors Cpmpact are top of therange pressure sensors.
Compact, sturdy and long-term stable, they areparticularly suitable for mobile conveying andlifting systems.
The compact design with G 1⁄4 B pressureconnection enables space-saving and low-weightinstallation. The materials and technology usedmake these pressure sensors insensitive tochemically aggressive media and mechanicalload.
Accuracy of 1% means routine checks of thetransducer are unnecessary.
Measuring ranges from 250 mbar up to 1000 bar,graded in accordance with EN, offer a wide rangeof possible applications.
The short response time of the pressure sensorof < 1 ms enables peak pressures withfrequencies of up to 150 Hz to be measured.Mini-Hirschmann plugs or cable outlets are usedto pick up the electrical output signals.
The Compact pressure sensors meet theelectromagnetic compatibility (EMC) to EN61326.
Features
O Compact design
O Pressure connection G1⁄4B
O High peak pressure resistance
O High alternating load resistance
O High long-term stabilityO Corrosion resistant stainless steel designO High mechanical load rating
O For dynamic and static measurements
Measuring ranges
Gauge pressurenegative -1...0 bar to -0.25...0 barpositive 0...0.25 bar to 0...1000 bar
Applications
Conveying and lifiting systems,Hydraulics and pneumatics,General mechanical engineering.
DE 706 epage 2/4
Technical data
Model 3272 3373 OptionPressure type negative or positive gauge pressure negative and positive gauge
pressureOutput signal
4...20 mA - 2-wire system0...20 mA - 3-wire system0...10 VDC - 3-wire system0...5 VDC - 3-wire system
Accuracy ±1 % of F.S. 1)Ranges accord. to EN 0 ... 0.25 bar
to0 ... 16 bar
0 ... 25 barto
0 ... 1000 bar
other measuring ranges onrequest
Sensor element piezoresistive thin filmRepeatability ≤ ± 0.05 % of F.S.Stability (annual) ≤ ± 0.2 % of F.S. in rated conditionsCase Stainless steelPressure connection G 1⁄4 B to DIN 16288 G1⁄2B, 1⁄4NPT, 1⁄2NPTWetted parts Stainless steel 1.4571 and 1.4542Overload limit ≤ 16 bar 3.5x; ≤ 600 bar 2x; > 600 bar 1.5x; vacuum
resistantElectrical connection Mini-Hirschmann plug G4a1MMT
Round connector M12x1, 4-pincabel outlet with1 m cable
Power supply 10....30 VDC (14...30 VDC for output 0...10 V)Power consumption Output 4...20 mA: signal current
output 0...20 mA: signal current + 4 mAvoltage output: 8 mA
Load
0.020A10VUB −≤ for current output
> 10 kOhm for voltage output 0...10 V> 5 kOhm for voltage output 0...5 V
Temp. compens. range 0....80°CTemperature influence ± 0.3 % /10 K, measuring range and zero pointResponse time ≤ 1 ms (within 10 % to 90 % v. EW.)Protection type IP 65 to EN 60 529/IEC 529, IP 67 for M12x1 connector IP67 for cable outletEmission 2) to EN 61326Interference 2) to EN 61326Electrical protection types polarity, overvoltage and short-circuit protectionTemperature ranges− Storage− Media− Ambient
-40 .... 100 °C-30 .... 100 °C-30 .... 85 °C
media temperature-40...125 °C
Weight approx. 0.10 kgof F.S.= of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis2) Declaration of conformity on request
DE 706 epage 3/4
Dimensions (mm)
CaseMini-Hirschmann plug round connector M12x1 cable outlet
55 27Max
.72
55 27
37
2755Max
. 72
Pressure connection
G 1⁄4 B G 1⁄2 B
2 2
13
5
9,5
G1/4
27
G1/2
6
17,5
3
320
27
Screw-in aperture according to DIN 16288
G 1⁄4 G 1⁄2
G1/4
5,5
16,5
+1
13-0
,5
Min
.9,5
A0.1
A
24,5
+1
19-0
,5
Min
. 14.
5
7
G1/2(DIN 16288)
A0.1
A
DE 706 epage 4/4
Electrical connection
Two-wire system
Mini-Hirschmann plug round connector M12x1 cable outletUB / S+
0V / S-
1234
E-031
UB / S+
0V / S-
1 2
4 3
E-033
UB / S+
0V / S-
brown
green
E-016
Three-wire system
Mini-Hirschmann plug round connector M12x1 cable outletUB
0V / S-
S+1
234
E-032
UB
0V / S-
S+
41
32
E-034
0V / S-
UB
S+
brown
green
white
E-018
Connection table for Mini-Hirschmann plug oder cable outlet4...20 mA(2 - wire)
0...10VDC(3 - wire)
Supply: UB+ 1 brown 1 brownSupply: 0V 2 green 2 greenSignal: S+ - - 3 whiteSignal: S- - - 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
DE 707 c Model: 3296, 3396page 1/4
Pressure sensors OEMwith internal diaphragmfor gauge pressure and absolute pressure
accuracy 1%
standard output: 4...20 mA; 2-wire system or 1...5 VDC; 3-wire system or 1...6 VDC; 3-wire system or 0...10 VDC; 3-wire system
Description
Pressure sensors OEM are top of the rangepressure sensors. With their technical qualitiesand the attractive price level, they are suitablefor OEM applications with mean and highquantities.
The compact sensor design with G 1⁄4 B pressureconnection enables space-saving and low-weightinstallation.
The materials and technology used make thesepressure sensors insensitive to chemically ag-gressive media and mechanical load.
Measuring ranges from 0...1 bar up to 0...1000bar, graded in accordance with EN, offer a widerange of possible applications. The overload limitup to 10 bar is 3.5x , between 16 and 600 bartwice and for 1000 bar 1.5x of the ratedpressure.
For connection of an electrical output signal,plugs according to DIN 43650 or cable outletsare available.
The OEM pressure sensors meet theelectromagnetic compatibility (EMC)requirements of EN 61326.
Features
O Corrosion resistant stainless steel designO Medium wetted parts of stainless steelO No internal sealing elements
O Pressure connection G1⁄4B
O High peak pressure resistance
O High alternating load resistance
O High long-term stability
O For dynamic and static measurements
Ranges
Gauge pressure 0...1 bar to 0...1000 barAbsolute pressure 0...1 bar to 0...10 bar
Applications
Pressure measurement for OEM applicationslike:
Automation,Machine and apparatus design,Air compression,Refrigeration and air conditioning,Lifting and conveyor systems.
DE 707 cpage 2/4
Technical data
Model 3296 3396 OptionPressure type absolute
pressurepositive or negative gauge pressure
Output signal 4...20 mA - 2-wire system1...5 VDC - 3-wire system1...6 VDC - 3-wire system0...10 VDC - 3-wire system
Accuracy ± 1 % of F.S. 1)Ranges according to EN 0 ... 1 bar
to0 ... 10 bar
0 ... 16 barto
0 ... 1000 bar
other ranges onrequest
Sensor element piezoresistive thin filmRepeatability ≤ ± 0.1 % of F.S.Stability (annual) ≤ ± 0.3 % of F.S.in rated conditionsCase stainless steel 1.4301Pressure connection G 1⁄4 B according DIN 16288 other pressure con-
nections on requestWetted parts stainless steel 1.4571 and 1.4542Overload limit ≤ 10 bar 3.5 x; ≤ 600 bar 2 x; 1000 bar 1.5 x; vacuum
resistantElectrical connection plug according to DIN 43650 with junction box cable outletPower supply 10....30 VDC, (14...30 VDC for voltage output)Power consumption output 4...20 mA: signal current
output 0...20 mA: signal current + 4 mAvoltage output: 8 mA
Load - 4…20 mA ≤ (UB [V] - 10V) / 0.020A- 0...10 V ≥ 10 KΩ- 1...5 V ≥ 5 KΩ- 1...6 V ≥ 6 KΩ
Temp. compens. range 0....80°CTemperature influence ± 0.4 % /10 K, zero and spanResponse time ≤ 5 ms (within 10 % to 90 % of F.S)Protection type IP 65 EN 60529 / IEC 529 IP 67 with cable outletEmission 2) according to EN 61326Interference 2) according to EN 61326Electrical protection types polarity, overvoltage and short-circuit protectionTemperature ranges− Storage− Medium− Ambient
-30 .... 100 °C-40 .... 100 °C-30 .... 80 °C
Weight approx. 0.15 kgof F.S.= of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis2) Declaration of conformity on request
DE 707 cpage 3/4
Dimensions (mm)
Caseplug according to DIN 43 650 cable outlet
48
42
35
75
G1/4
SW19
213
59.5
2
42
35
G1/4
SW19
213
59.5
2
Screw-in aperture according to DIN 16288
G 1⁄4
G1/4
5,5
16,5
+1
13-0
,5
Min
.9,5
A0.1
A
S-002
DE 707 cpage 4/4
Electrical connection
Two-wire system
DIN 43650 plug OEM cable outlet
UB / S+
0V / S-
1
3
2
E-003
UB / S+
0V / S-
brown
green
1
2
E-020
Three-wire system
DIN 43650 plug cable outlet
UB
0V / S-
1
3
2
S+
E-004
0V / S-
UB
S+
brown
green
white
1
3
2
E-022
Connection table for DIN plug or cable outlet4...20 mA(2-wire)
0...10 VDC(3-wire)
Supply: UB+ 1 1Supply: 0V 2 2Signal: S+ - 3Signal: S- - 2
Order details1. Model2. Measuring range3. Output signal4. Options
Technologies for Sensors Indicators and Systems | Pressure | Temperature | Force
tecsis GmbHAn der Sandelmühle 13D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Pressure Sensors working on the Hall effectprinciplefor gauge pressure
Accuracy 1%
Standard output: 4 . . . 20 mA; 2-wire systemor 0 . . . 5 VDC; 3-wire systemor 0 . . . 10 VDC; 3-wire system
DescriptionPressure sensors working on the hall effect principle pro-vide a low prieced solution for many measuring tasks.
With aid of a flexible measuring element and by applyingthe hall effect the pressure to be measured is convertedinto an electrical signal.
The compact sensor design with G 1/4 B pressureconnection enables space-saving and low-weight installa-tion.
The long-term experienced components are fitted in astainless steel casing.
The wetted parts consist either of stainless steel 1.4571or a copper alloy.
For connection of an electrical output signal, plugs accor-ding to DIN 43 650 or cable outlets are available.
For applications in the field of refrigeration pressure sen-sors with special pressure connection (7/16 UNF femalethread Schrader and copper tube for weld-on connection)are available. Other versions can be delieverd on request.
A particulary inexpensive version is available for OEM ap-plications.
The pressure sensors meet the electromagnetic compati-bility (EMC) to EN 61 326.
Features Inexpensive solution for many measuring
tasks
Chemically resistant wetted parts
Stainless steel case
Pressure connection G 1/4 B
Special pressure connections forrefrigeration
DIN plug or cable outlet
RangesGauge pressurenegative -1 . . . 0 bar to -0.4 . . . 0 barpositive 0 . . . 0.4 bar to 0 . . . 600 bar
ApplicationsPneumatic and hydraulic control systems,General mechanical engineering,Refrigeration machinery.
DE 7 10 c
P. 1 / 4
Models: 3300, 3305, 3306, 3308, 3310
DE 7 10 c
P. 2 /4
Technical dataModelPressure type
Output signal
Accuracy % of F. S.Ranges to EN
Sensor elementRepeatabilityStability (annual)CasePressure connection
Wetted parts
Overload limitElectrical connectionPower supply
Power consumption
Load
Temperature influenceResponse timeVibration
Protection typeEmission 4)Interference 4)Temperature ranges
- Storage- Medium- Ambient
WeightOrifice
Special design
negative or positive gauge pressure
4 . . . 20 mA - 2-wire system0 . . . 5 VDC - 3-wire system0 . . . 10 VDC - 3-wire system
1 1) 2) 1.6 1) typ. 1.60 . . . 0.4 bar 0 . . . 1 bar
to to0 . . . 600 bar 0 . . . 600 bar
flexible measuring element and hall sensor≤ ± 0.1% of F. S.≤ ± 0.4% of F.S. in rated conditionsStainless steel 1.4301G 1/4 B to DIN 16 288, 7/16-20 UNF 90° male threadtube connection7/16-20 UNF female thread Schrader
CuZn s.s. 1.4571 CuZn (Brass)(Brass)
2 x; > 400 bar 1.3 xPlug to DIN 43 650 with junction box12 . . . 30 VDCmax. permissible residual ripple: 10% ssoutput 4 . . . 20 mA: signal currentvoltage output: 8 mA
≤ UB - 12 V for output 4 . . . 20 mA0.020 A
> 5 kOhm for output 1 . . . 5 V> 10 kOhm for output 0 . . . 10 V± 0.5%/10 K, on zero and span≤ 40 ms (within 10% to 90% of F. S.)Deviation ≤ 1% of F. S.; for 10 . . . 150 Hz at 4 gin each direction; for ranges ≥ 6 barIP 65 EN 60 529/ IEC 529 IP 43to EN 61 326to EN 61 326
-35 . . . + 80 °C-25 . . . + 80 °C-25 . . . + 60 °Capprox. 0.2 kg approx. 0.15 kg
Optionnegative and positive gauge pressure1 . . . 5 VDC;1 . . . 6 VDC;3-wire system
other ranges on request
1/4 NPT
Stainless steel 1.4571 formodel 3305 and 3308
cable outlet8 . . . 30 VDC for output1 . . . 5 V 3)
Ø 0.4 or Ø 0.8others on requestfor oxygen
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis. of F. S. = of full scale valueFor measuring ranges < 2.5 bar the accuracy quoted only applies when installed in the adjusting position(pressure position bottom). For different installation positions please indicate adjustment position.
2) For range 0 . . . 0.4 bar, accuracy 1.6%3) If power supply < 12 V, accuracy 1.6%4) Declaration of conformity on request
3300 3310 3308 3305 3306
Dimensions (mm)Case
DIN 43 650 plug cable outlet DIN 43 650 plug cable outlet
DE 7 10 c
P. 3 / 4
Pressure connection Screw-in aperture according to DIN 16 288G 1/4 B G 1/4 B
Special connections for refrigeration7/16-20 UNF 90° tube connection 7/16 UNF female thread
Schrader
Model: 3300, 3305, 3306 and 3310Model 3308
tecsis GmbHAn der Sandelmühle 13D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Modifications reserved
DE 7 10 c
P. 4 / 4
Supply: UB+Supply: 0VSignal: S+Signal: S-Shield
Connection table for DIN plug or cable outlet
Order details1. Model2. Measuring range3. Output signal4. Options
4 . . . 20 mA(2-wire)
0 . . . 10 VDC(3-wire)
12----
brownwhite
------
brown whitegreenwhite
--
1232
Electrical connection
Two-wire systemDIN 43 650 plug cable outlet
Three-wire systemDIN 43 650 plug cable outlet
Technologies for Sensors Indicators and Systems Pressure Temperature Force
model: 3301tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 711a
p. 1/3
Pressure Sensors „MagTrans“for OEM-Applikations
Description
Pressure Sensors „MagTrans“ are the idealsolution for Oem applications for mid to highquantities. This is a result of good technicalspecifications and a very attractive price level.Due to the use of state of the art production lineswe are able to provide short lead times and highquality.
The compact design with G 1⁄4 B pressureconnection enables space-saving and low-weightinstallation.
By using components approved in large-volumeproduction „MagTrans“ reaches a very highdegree of reliability for an extreme favourableprice.
As a standard the pressure sensor provides anstandardized voltage output. For applicationsextremly critical in price a ratiometric output canbe obtained.
Round connectors M12x1 or cable outlets areused to pick up the electrical output signals.
The pressure sensors “MagTrans” meet theelectronic magnetic compatibility (EMC)requirements to EN 61326.
Features
O accuracy 1%O compact designO very good price-performance ratioO components approved in large-volume
productionO various voltage outputs
Pressure ranges
gauge pressurenegative -1 ... 0 bar to -0.1 ... 0 barpositive 0 ... 0.1 bar to 0 ... 25 bar
Applications
OEM applications:Pumps and compressors,Pneumatics,Building services engineering,Refrigeration.
DE 711a
p. 2/3
Technical dataModel 3301Pressure type positive and / or negative gauge pressurePressure range [bar] 0.1 0.16 0.25 0.4 0.6 1.0 1.6 2.5 4 6 10 16 25Overload limit [bar] 0.8 1.2 2 3,2 4,8 3.0 4.8 7.5 12 18 20 24 40Burst pressure [bar] 4 14 16 16 24 28 24 24 40 72 96 56 68Output signal 0.5 ... 4.5 VDC ratiometric
0...5 VDC 3-wire0...10 VDC 3-wireother on request
Power supply− 0.5 ... 4.5 VDC− 0...5 VDC− 0...10 VDC
5 VDC ± 10%8...30 VDC12...30 VDC
Current consumption 9 mALoad− 0.5 ... 4.5 VDC− 0...5 VDC− 0...10 VDC
> 4.5 kΩ> 5 kΩ> 10 kΩ
Residual ripple max. 5% ssAccuracy 1) 1.0% typ.Repeatability 0.06%Hysteresis 0.4% typ.Stability per year 0.4% (in rated conditions)Electr. connection round connector M12x1 (4-pin),
cable outlet with 2 m cablePressure connection G 1⁄4, G 1/8, 1⁄4 NPT
M10x1, M12x1,57/16-20 UNF Schrader
Materials- case− case top− wetted parts
BrassPlasticBrass, Ni- / Cu-alloy
Temp.comp. range -20...80°CTemperature range− media− ambient− storage
-20 ... 80°C-20 ... 80°C-40 ... 100°C
Temperature inflence- zero point- span
0.4% / 10K typ.0.4% / 10K typ.
Protection type IP65 to EN60529IP67 for cable outlet
Response time ≤ 10 ms (within 10 % to 90 % of F.S.)Emmission to EN 61 326Interference to EN 61 326Shock resistance 350g according to IEC 770 (mechanical shock)Vibration resistance 10g according to IEC 770 (vibration under resonance)Electrical Protection reverse polarity and overvoltage protectionWeight approx. 90g1) Start point adjustment to DIN 16086
DE 711a
p. 3/3
Dimensions
round connector M12x1, 4-pin cable outlet
Electrical connection
UB
0V / S-
S+
41
32
E-034
UB
S+
0V-
Braun/brown/brun
Schwarz/black/noir
Blau/blue/bleu
E-022.1
round connector M12x1, 4-pin cable outlet
Subject to technical changes
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models: 3382tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 715d
p. 1/4
Pressure Precisionwith internal diaphragmfor gauge pressure and absolute pressure
accuracy 0.05% and 0.1 %
standard output: RS 232-interface or 4...20 mA; 2-wire system or 0...20 mA; 3-wire system
Description
Pressure sensors Precision are top of the rangeprescision pressure sensors.
With a standard accuracy of 0.1% and optionalaccuracy of 0.05%, these pressure sensors areparticularly suitable for use in testing orcalibration systems. The program-controlled tem-perature compensation system practically elimi-nates temperature-related measurement errors inthe range 0°C to 50°C.
The front flush pressure diaphragm avoidszones, in which medium could crystallize orresidues could form, thus ensuring trouble-freepressure measurement and hygenic cleaning ofthe pressure sensor.
Their long-term stability, good corrosion resistance,high protection (IP 67) and mechanical load ratingalso make the pressure sensors precision suitablefor use in demanding measuring jobs in harshindustrial environments.
For special measuring jobs, the zero point andmeasuring range can be reset with an IBMcompatible PC. The necessary software for thisand for the determination, storage and output ofthe measured values can be supplied.
The pressure sensors Precision meet theelectromagnetic compatibility (EMC) to EN61326.
Features
O High accuracy
O High long-term stability
O Temperature influence practically none
O Corrosion resistant stainless steel designO Serial interface
Measuring ranges
Gauge pressurenegative -1...0 bar to -0.25...0 barpositive 0...0.25 bar to 0...1000 barAbsolute pressure 0...0.25 bar to 0...16 bar
Applications
Testing and calibration systems,Development and production.
DE 715d
p. 2/4
Technical data
Model 3382 OptionPressure type negative or positive gauge
pressureabsolutepressure
negative and positivegauge pressure
Output signal 4 ... 20 mA - 2-wire system0 ... 20 mA - 3-wire system
RS 232-interface
0...5 VDC; 0...10 VDC;4 ... 20 mA3 -wire system
Accuracy % of F.S. 1) ± 0.1 % of F.S. ± 0.05 % of F.S.Ranges accord. to EN 0 ... 0.25 bar
to0 ... 16 bar
0 ... 25 barto
0 ... 1000 bar
0 ... 0.25 barto
0 ... 16 bar
0 ... 1600 bar
Sensor element Piezoresistive thin film piezoresistiveRepeatability ≤ ± 0.03 % of F.S.Stability (annual) ≤ ± 0.1 % of F.S. in rated conditionsCase Stainless steel 1.4571Pressure connection G 1⁄2 B accord. to DIN 16 288 G1⁄4B; 1⁄2NPT; 1⁄4NPTWetted parts Stainless steel 1.4571Overload limit ≤ 16 bar 3.5-fold; ≤ 600 bar 2-fold; > 600 bar 1.5-fold;Electrical connection− analogue output cablel outlet with 1.5m cable 8-pin plug− RS 232-interface 9-pin sub-D plugPower supply− analogue output 14....30 VDC, (10...30 VDC for output 4...20 mA 2
wire)− RS 232-interface supply from interfacePower consumption max 30 mA current output
< 25 mA voltage outputLoad− current output (3-L)− current output (2-L)− 0...5 V− 0...10 V
RA[Ω ] ≤ (UB[V] – 14V) / 0.02 ARA[Ω ] ≤ (UB[V] – 10V) / 0.02 A> 5 kOhm> 10 kOhm
Temp. compens. range -20.... 80°CTemperature influence− -20...0°C ≤ 0.1 % /10 K, on zero and span− 0...50°C None− 50...80°C ≤ 0.1 % /10 K, on zero and spanAdjustability of zero and span; programmable− analogue output Software and cable set available as accessoires− RS 232-interface Software incl. in delivery contentsResponse time ≤ 80 ms (within 10 % to 90 % of F.S.)Protection type IP 67 EN 60 529 / IEC 529 IP 65 with plugEmission 2) to EN 61326Interference 2) to EN 61326Temperature ranges− Storage− Medium− Ambient
-40 .... 85 °C-20 .... 80 °C-20 .... 80 °C
Weight Approx. 0.30 kgof F.S. = of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis(calibrated in vertical installation position, pressure connection bottom)
2) Declaration of conformity on request
DE 715d
p. 3/4
Dimensions (mm)
Case
40
57
72
Pressure connection
G 1⁄4 B G 1⁄2 B
2 2
13
5
9,5
G1/4
27 27
G1/2
6
17,5
3
320
Screw-in aperture to DIN 16 288
G 1⁄4 G 1⁄2 B
G1/4
5,5
16,5
+1
13-0
,5
Min
.9,5
A0.1
A
24,5
+1
19-0
,5
Min
. 14.
5
7
G1/2(DIN 16288)
A0.1
A
DE 715d
p. 4/4
Electrical connection
Two-wire-system
Cable outlet 8-pin connectorUB / S+
0V / S-
brown
green
blueSchirm
UB / S+
0V / S-
1345
7
2
86
Three-wire-system
Cable outlet 8-pin connector
0V / S-
UB
S+
brown
green
white
blueschield
UB
S+
0V / S-
RS 232 Interface
brownyellow
white
Sub-D-plugPressure sensorSub-D-plug
RXRTTXD
DT
GN
Pressure sensor
Order details1. Model2. Measuring range3. Output signal4. Options
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models: 3383tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 716d
p. 1/4
Pressure Sensors Precisionwith front-flush diaphragmfor gauge pressure and absolute pressure
accuracy 0.05 % and 0.1 %
standard output: RS 232-interface or 4...20 mA; 2-wire system or 0...20 mA; 3-wire system
Description
Pressure sensors precision are top of the rangeprescision pressure sensors.
With a standard accuracy of 0.1% and optionalaccuracy of 0.05%, these pressure sensors areparticularly suitable for use in testing orcalibration systems. The program-controlled tem-perature compensation system practically elimi-nates temperature-related measurement errors inthe range 0°C to 50°C.
The front flush pressure diaphragm avoidszones, in which medium could crystallize orresidues could form, thus ensuring trouble-freepressure measurement and hygenic cleaning ofthe pressure sensor.
Their long-term stability, good corrosion resistance,high protection (IP 67) and mechanical load ratingalso make the pressure sensors precision suitablefor use in demanding measuring jobs in harshindustrial environments.
For special measuring jobs, the zero point andmeasuring range can be reset with an IBMcompatible PC. The necessary software for thisand for the determination, storage and output ofthe measured values can be supplied.
The pressure sensors precision meet theelectromagnetic compatibility (EMC) to EN61326.
Features
O High accuracy
O High long-term stability
O Temperature influence practically none
O Corrosion resistant stainless steel designO Laser-welded front-flush diaphragmO Serial interface
Measuring ranges
Gauge pressurenegative -1...0 bar to -0.25...0 barpositive 0...0.25 bar to 0...600 barAbsolute pressure 0...0.25 bar to 0...16 bar
Applications
Testing and calibration systems,Development and production
DE 7X16d
p. 2/4
Technical data
Model 3383 OptionPressure type negative or positive gauge pressure absolute pressure negative and positive
gauge pressureOutput signal 4 ... 20 mA - 2-wire system
0 ... 20 mA - 3-wire systemRS 232-interface
0...5 VDC; 0...10 VDC;4 ... 20 mA3-wire system
Accuracy % of F.S. 1) ± 0.1 % of F.S. ± 0.05 % of F.S.Ranges accord. to EN 0 ... 0.25 bar
to0 ... 16 bar
0 ... 25 barto
0 ... 600 bar
0 ... 0.25 barto
0 ... 16 barSensor element piezoresistive Thin film piezoresistiveRepeatability ≤ ± 0.03 % of F.S.Stability (annual) ≤ ± 0.1 % of F.S. in rated conditionsCase Stainless steel 1.4571Pressure connection ≤ 1.6 bar G 1 B; ≥ 2.5 bar G 1⁄2 BWetted parts Stainless steel 1.4571Overload limit ≤ 16 bar 3.5-fold; ≤ 600 bar 2-foldElectrical connection− Analogue output cabel outlet with 1.5m cable 8-pin plug− RS 232-interface 9-pin sub-D plugPower supply− Analogue output 14....30 VDC (10...30 VDC for output 4 ... 20 mA 2 wire)− RS 232-interface voltage supply from interfacePower consumption max 30 mA with current output
< 25 mA with voltage outputLoad− current output (2-L)− current output (3-L)− 0...5 V− 0...10 V
RA[Ω ] ≤ (UB[V] – 10V) / 0.02 ARA[Ω ] ≤ (UB[V] – 14V) / 0.02 A> 5 kOhm> 10 kOhm
Temp. compens. range -20... 80°CTemperature influence− -20...0°C ≤ 0.1 % /10 K, on zero and span− 0...50°C None− 50...80°C ≤ 0.1 % /10 K, on zero and spanAdjustability of zero and span;programmable− Analogue output software and cable set available as accessoires− RS 232-interface software incl. in delivery contentsResponse time ≤ 80 ms (within 10 % to 90 % of F.S.)Protection type IP 67 to EN 60 529/IEC 529 IP 65 with plugEmission 2) to EN 61326interference 2) to EN 61326Temperature ranges− Storage− Medium− Ambient
-40 .... 85 °C-20 .... 80 °C-20 .... 80 °C
Weight approx. 0.30 kgof F.S. = of full scale value
1) Termninal point adjustment according to DIN 16 086, incl. linearity and hysteresis(calibrated in vertical installation position, pressure connection bottom)
2) Declaration of conformity on request
DE 7X16d
p. 3/4
Dimensions (mm)
Case
40
57
72
Pressure connection
G 1⁄2 B G 1 B
36,5
32
20,5
10
18 -0,1
G1/2B
18,5 x 23,9 x 1,5
15 x 2
27
33
20,5
10
30 -0,1
41
29,7 x 35,7 x 2
26 x 2
G1B
Weld-on adapter or screw-in aperture
G 1⁄2 B G 1B
50
21.3-0,2
G1/2
19.4+0.1
21
18.2+0.1
15-0
.2
Min
.10.
5
0.1 A
A
50
33.5 -0.2
G1
30.5 +0.1
30.1 +0.1
2115-0
.2
Min
.10.
5
0.1 A
A
DE 7X16d
p. 4/4
Electrical connection
Two-wire-system
Cable outlet 8-pin connectorUB / S+
0V / S-
brown
green
blueSchirm
UB / S+
0V / S-
1345
7
2
86
Three-wire-system
Cable outlet 8-pin connector
0V / S-
UB
S+
brown
green
white
blueschield
UB
S+
0V / S-
RS 232 Interface
brownyellow
white
Sub-D-plugPressure sensorSub-D-plug
RXRTTXD
DT
GN
Pressure sensor
Order details1. Model2. Measuring range3. Output signal4. Option
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models: E110, E111, E112, E113, E120, E121, E122, E123tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 722b
p. 1/4
- Pressure Sensors Industrial Heavy DutyEEx ia IIC T4 - T6
according to ATEX 100a- with internal diaphragm- with front flush diaphrgam
for gauge and absolute pressure
accuracy 0,25% and 0,5 %
standard output: 4...20 mA; 2-wire system
Description
-pressure sensors Industrial Heavy Duty aretop of the range products in Ex pressure gaugetechnology.
The intrinsically safe Ex-pressure sensors aredesigned for zone 1 and have special type ap-proval for use in potentially explosiveatmospheres and a CENELEC certificateaccording to the new ATEX 100a. The newregulation will be valid after 30.06.2003.
The measuring ranges, graded in accordancewith EN, range from 100 mbar to themaximum pressure range of 4000 bar. Thecase and wetted parts comprise stainless steeland are thus resistant to chemically aggressivemedia. The pressure connection andmeasuring element are welded together,making the measuring system particularlyresistant to mechanical shock or vibration.The pressure connection is fitted with a G 1⁄2male thread. Several electrical connectionscan be obtained to pick up the electrical outputsignal.
The front flush pressure diaphragm avoidszones, in which medium could crystallize orresidues could form, thus ensuring trouble-freepressure measurement and hygienic cleaningof the pressure sensors.
The Ex-pressure sensors Industrial HeavyDuty meet the electronic magneticcompatibility (EMC) requirements to EN61326.
FeaturesO intrinsically safe, zone 1O option: build to zone 0O for pastous or crystallizing mediaO high longterm stabilityO finely graded selection of nominl pressure
ranges according to ENO corrosion resistant stainless steel designO good repeatabilityO high overload protectionO for dynamic and static measurementsO simple installationO CENELEC-certificate acc. to ATEX 100a
Measuring rangesGauge pressureNegative -1...0 bar to -0.1...0 barPositive 0...0.1 bar to 0...4000 barAbsolute pressure 0...0.25 bar to 0 ... 16 bar
ApplicationsChemical and pharmaceutical industry,food industry and environmental technology,Process engineerging.
Technical data
DE 722b
p. 2/4
Model E110 E111 E112 E113 E120 E121 E122 E123Type with internal diaphragm with front flush diaphrgamPressure type negative / positive
gauge pressureabsolute pressure negative / positive
gauge pressureabsolute pressure
Output signal 4...20 mA - 2-wire systemAccuracy % of F.S. 1) 0.5 0.25 0.5 0.25 0.5 0.25 0.5 0.25Measuring ranges acc. to EN 0 ... 0.1 bar 2)
to0 ... 4000 bar
0 ... 0.25 barto
0 ... 16 bar
0 ... 0.1 bar 2)to
0 ... 600 bar
0 ... 0.25 barto
0 ... 16 barRepeatability ≤ ± 0.05 % of F.S.Stability (anual) ≤ ± 0.2 % of F.S. in rated conditionsCase stainless steel 1.4571Process connection 3) G 1⁄2 B (option: G 1⁄4 B, 1⁄2 NPT, 1⁄4 NPT) ≤ 1.6 bar G 1 B; ≥ 2.5 bar G 1⁄2 BWetted parts Stainless steel 1.4571 and 1.4542 stainless steel 1.4571
O-ring NBR (option: Viton, EPDM)Overload limit < 16 bar 3.5-fold; < 600 bar 2-fold; > 600 bar 1,5-fold; vacuum proofElectr. connection and plug acc. to DIN EN 175301 - 803 with junction box (PG 9), IP 65protection type acc. to option:EN 60 529 / IEC529 plug acc. to DIN EN 175301 - 803 with junction box (PG13.5), IP 65 for ship approval
round connector M12x1 (4-pin), IP 67snap cap (PG 11), IP 67MIL-plug (6-pin), IP 7rond connector M 16x0.75 (5-pin ), IP 67cable outlet IP 67 with 1.5 m cable with inner ventilationcable outlet IP 68 with 1.5 m cabIe with inner ventilation (zero / span adjustable)cable outlet IP 68 with 1.5 m cabIe with inner ventilation (zero / span not adjustable)
Power supply 10 ... 30 VDC (snap cap: 11...30 VDC)Power consumption signal currentLoad RA[Ω ] ≤ (UB[V]-10V)/0,02A - ( 0,14[Ω ] x cable length in [m] )Temperature comp. Range 0....80 °C.Temperature influence 4) ≤ 0.2 % /10 K on zero and spanAdjustability Zero and span up to ± 10%Response time ≤ 1 ms (within 10 % to 90 % of. F.S.)Protection type IP 65 to EN 50529/IEC529Emission 5) according to EN 61326Interference 5) according to EN 61326HF immunity 10 V/m (option: 30 V/m)Burst 4 KVElectrical protection types reverse polarity protection
Explosion proof protection type EEx ia IIC T4 EEx ia IIC T5 EEx ia IIC T6max. values: DMT- power supply <30 VDC- short circuit current 100 mA- power restriction 6) 1 W- media temperature 7) -20 [-50] ... 105 °C -20 [-50] ... 80 °C -20 [-50] ... 60 °C- ambient temperature 7) -20 [-50] ... 105 °C -20 [-50] ... 80 °C -20 [-50] ... 60 °C- storage temperature -50 ... 105 °C- internal capacity ≤ 22 nF- internal inductivity ≤ 100 µHTemperaturbereiche- storage -30 ... 100 °C- media -30 ... 100 °C (option: -50...105 °C)- ambient -30 ... 100 °C (option: -50...105 °C)Weight approx. 0.2 kg
1) Terminal point adjustment according to DIN 16 086, including linearity and hysteresis of F.S. = of full scale value2) Accuracy 0.25% only for ranges ≥ 0 ... 0.25 bar3) From 0...2500 bar M16x1.5 female for attachment to zone 0 connection pressure connection acc. to 4.5 EN 502844) ≤ 0.4 % /10 K; for ranges 0...0.1 and 0...0.16 bar5) Declaration of conformity on request6) Power limitation for supply transformers7) See listing according to EC Type Test certificate
DE 722b
p. 3/4
Dimensions (mm)Case
plug to DIN 43650IP 65
snap cap IP 67
plug to DIN 43650for ship approvals IP 65
4-pi
n ro
und
conn
ecto
rM
12x
1IP
67
cab
le o
utle
t IP
67
MIL
-plu
g IP
67
5-pi
n ro
und
conn
ecto
rM
16x
0,75
IP67
cabel outlet with accessto zero and span potentiometer IP 68
cabel outlet without accessto zero and spanpotentiometer IP 68
Pressure connection- internal diaphragm - front flush diaphrgam
A-006
G1/2
6
17,5
3
320
27
19.5
12
4,8
60°
M16 x 1,5
26.5
27
A-020
20,5
10
18 -0,1
G1/2
18,5 x 23,9 x 1,5
15 x 2
27
A-016
29,7 x 35,7 x 2,0
26 x 2
41
G1 B
3120
,510
,5
30 -0,1
10
A-012
Screw-in aperture Weld-on adapter- internal diaphragm - front flush diaphrgam
24,5
+1
19
-0,
Min.14.5
7
G1/2(DIN 16288)
A0.1
A
S-001
M16X1.560°
4.8
S-008
50
21.3-0,2
G1/219.4+0.1
21
18.2+0.1
15-0
.2
Min
.10.
5
0.1 A
A
S-003
50
33.5 -0.2
G130.5 +0.1
30.1 +0.1
2115-0
.2
Min
.10.
5
0.1 A
A
S-004
DE 722b
p. 4/4
Electrical connection
Two-wire system
plug to DIN 43 650 cable outlet
UB / S+
0V / S-
13
2
E-001
UB / S+
0V / S-
brown
green
E-016
snap Cap 4-pin round connector M12 x 1
UB / S+
0V / S-
Test +Test -
13
45
2E-054
UB / S+
0V / S-
1 24 3
E-033
MIL-plug PT 02 E-10-6P 5-pin round connector M16 x 0.75
UB / S+
0V / S-
AE CD
BF
E-011
UB / S+
0V / S-
1
24 3
5
E-035
Order details:1. Model2. Measuring range3. Options4. Ex-Zone
Technologies for Sensors Indicators and Systems | pressure | temperature | force
tecsis GmbHCarl-Legien-Str. 40D-63073 Offenbach / Main Sales Inland Export Sales E-Mail [email protected]. +49 (0) 69 / 58 06-0 Fax +49 (0) 69 / 58 06-1 70 Fax +49 (0) 69 / 58 06-1 77 Internet www.tecsis.de
-Pressure Sensors EEx ia IIC T6according to ATEX 100a
with internal diaphragm
for submersible pressure measurement
accuracy 0.25% and 0.5%
standard output: 4 . . . 20 mA; 2-wire system
Description
-pressure sensors Industrial Heavy Duty are top of therange products in Ex pressure gauge technology.
The intrinsically safe Ex-pressure sensors are designedfor zone 1 and have special type approval for use in po-tentially explosive atmosphere and a CENELEC certifica-te according to the new ATEX 100a. The new regulationwill be valid after 30.06.2003.
Due to the systematic use of high-grade stainless steelfor the wetted parts, this sensor is suitable for aggressivemedia. For measuring tasks in aggressive media a speci-al version with PTFE cable can be obtained.
A hermetically sealed stainless steel case allows thepressure sensor to be immersed down to a depth of 300m.
The inner vented connection cable makes pressure com-pensation of the measuring cell against the atmospherepossible and thus hydrostatic pressure measurement.
The mechanical fastening of the pressure sensor doesnot require any additional strain relief, as the constructionof the cable is suitable to take a maximum tensile force of1000 N. An additional weight can be screw-fitted to in-crease the actual weight of the sensor.
The pressure sensors special meet the electronic magne-tic compatibility (EMC) requirements to EN 61326.
Features
intrinsically safe, zone 1
option: zone 0
finely graded selection of nominal pressure rangesaccording to EN
high longterm stability
high accuracy
corrosion resistant stainless steel design
good repeatability
high overload protection
for dynamic and static measurements
simple installation
CENELEC-certificate acc. to ATEX 100a
Measuring ranges
gauge pressurepositive 0 . . . 0.1 bar to 0 . . . 25 bar
Applications
Level measurement in explosive atmosphere
DE 7 24 b
P. 1 / 4
Model: E130, E131
0.250 . . . 0.25 bar
to0 . . . 25 bar
0.50 . . . 0.1 bar
to0 . . . 25 bar
positive gauge pressure4 . . . 20 mA - 2-wire system
≤ ± 0.05% of F.S.≤ ± 0.2% of F.S. in rated conditionsG 1/2 B with protection cap
stainless steel 1.4571 stainless steel 1.4571stainless steel 1.4571PUR (option: PTFE up to 10 bar)Polyolefin (not for PTFE cable)≤ 1.6 bar 5-fold; > 1.6 bar 3.2-foldcable with inner ventilation, tensile strengh max. 1000 NIP 68 according to EN 60 529/IEC 529(depth up to 300 m)10 . . . 30 VDC signal currentRA[Ω] ≤ (UB[V]-10V)/0.02A - (0.14[Ω] x cable length in [m])0 . . . 50 °C≤ 0.2% / 10 K on zero and span≤ 1 ms (within 10% to 90% of F.S.)according to EN 61 326according to EN 61 32610 V/m (option 30 V/m)4 KVReverse polarity protectionEEx ia IIC T6DMT< 30 VDC100 mA1 W-10 . . . 60 °C-10 . . . 60 °C-10 . . . 60 °C≤ 22 nF + 0.2 per m cable≤ 100 µH + 2 per m cable
0.20 kg0.08 kg per m cable0.50 kg
E130 E131
DE 7 24 b
P. 2 /4
Technical dataModelPressure typeOutput signalAccuracy % of F.S. 1)Measuring ranges acc. to EN
RepeatabilityStability (anual)Pressure connection Wetted parts- case- diaphr. and pressure connection- protection cap- cable- shrink hoseOverload limitElectrical connectionProtectiontypePower supplyPower consumptionLoad Temperature comp. rangeTemperature influence 2)Response timeEmission 3)Interference 3)HF immunityBurstElectrical protection types
Explosion proof protection typemax. values- power supply- short circuit current- power restriction 4)- media temperature- ambient temperature- storage temperature- internal capacity- internal inductivityWeight - sensor- cable- additional weight
1) Terminal point adjustment according to DIN 16 086, including linearity and hysteresis of F.S. = of full scale value2) ≤ 0.4% / 10 K for measuring ranges 0 . . . 0.1 bar and 0 . . . 0.16 bar3) Declaration of conformity on request4) Power limitation for supply transformers
DE 7 24 b
P. 3 / 4
Electrical connection
Two-wire system
Dimensions (mm)
Option: PTFE cable
tecsis GmbHCarl-Legien-Str. 40D-63073 Offenbach / Main Sales Inland Export Sales E-Mail [email protected]. +49 (0) 69 / 58 06-0 Fax +49 (0) 69 / 58 06-1 70 Fax +49 (0) 69 / 58 06-1 77 Internet www.tecsis.de
Modifications reserved
DE 7 24 b
P. 4 / 4
Order details:1. Model
2. Measuring range
3. Options
4. Ex-zone
5. Cable length
Modifications reserved
Accessories To increase the actual weight of the sensoran additional weight can be screw-fitted.
Article-no. ZM51.001.001
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models:3233,3230tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 725c
p. 1/4
Pressure Sensors Specialfor submersible measurementaccuracy 0.25% and 0.5%
standard signal: 4...20 mA; 2-wire system or 0...20 mA; 3-wire system
Description
The pressure sensor special for submersiblemeasurement has been developed especially foruse in liquids for hydrostatic level measurement.Due to the systematic use of stainless steel forthe wetted parts, this sensor is suitable for thefood industry without any restrictions. Formeasuring tasks in aggressive media a specialversion with PTFE cable can be obtained.A hermetically sealed stainless steel case with aprotection type IP 68 allows the pressure sensorto be immersed down to a depth of 300 m.The inner vented connection cable makespressure compensation of the measuring cellagainst the atmosphere possible and thushydrostatic pressure measurement.The mechanical fastening of the pressure sensordoes not require any additional strain relief, asthe construction of the cable is suitable to take amaximum tensile force of 1000 N. An additionalweight can be screw-fitted to increase the actualweight of the sensor.For mains-independent service in the field, thesensor can operate with a supply voltage of 6V.The sensor can be obtained with a lightningprotection.To determine the media temperaturethe submersible sensor can be equiped with a PT100 sensor.The pressure sensor special for submersiblemeasurment meets the electromagneticcompatibility (EMC) requirements to EN 61326.
Features
O Compact design
O Protection type IP 68 (up to 300m depth)O Corrosion resistant stainless steel designO PUR sheathed cable with inner ventilationO Tensile strength of the cable 1000 NO Option: lightning protectionO Option: PTFE cableO Option: Temperature measurement (PT 100)
Measuring ranges
Gauge pressurepositive 0...0.1 bar up to 0...25 bar
Applications
Water level measurement in:Potable water bells,Bore holes,Waste water plants,Containers,Flow water.
DE 725c
p. 2/4
Technical dataModel 3233 3230 Option 1)Pressure type positive gauge pressureOutput signal 4...20 mA, 2-wire system 4...20 mA, 2-wire
system0...20 mA, 3-wiresystem
0...5 VDC; 0...10 VDC;0.5...2.5 VDC 1)3-wire system;PT 100, 4-wire system(DIN IEC 751)
Accuracy 2) ± 0.5 % of F.S. ± 0.25 % of F:S.Ranges accord. to EN 0 ... 0.25 bar
to0 ... 10 bar
0 ... 0.1 barto
0 ... 25 bar
other ranges on request
Sensor element piezoresistiveRepeatability ≤ ± 0.05 % of F.S.Stability per year ≤ ± 0.2 % of F.S. in rated conditionsPressure connection G 1⁄2 with protection capWetted parts− case 3)− protection cap
stainless steel 1.4571PA
− cable PUR PUR , Polyolefine(shrink hose)
PTFE 4)
Over load limit ≤ 1 bar, 5x; ≤ 4 bar, 4x; ≤ 25 bar, 3.2xElectrical connection connection cable (PUR-sheathed with inner ventilation,
tensile strengh 1000 N)Power supply 10....30 VDC (14...30 VDC, for output 0...10 V)
(6...30 VDC for output 0.5...2.5 V)Power consumption− 4...20 mA− 0...20 mA− 0.5...2.5 V− voltage output
current signalcurrent signal + 4 mAapprox. 2 mA8 mA
Load− current output− voltage output
* 14.0m0.020A
10VUB Ω−−≤ cable lengh
≥ 100 kOhmTemp. compens. range 0.... 50°CTemperature influence ± 0.2 % /10 K, on zero and span 5)Response time ≤ 1 ms (within 10% to 90% of F.S.)Emission 6) accord. to EN 61326Interference 6) accord. to EN 61326
IP 68 accord. to EN 60 529 / IEC 529Protection type− depth up to 100 m up to 300 mElectrical protection type polarity, overload and short circuit protection lightning protection (IEC 801-
5; 1.5 kV)Temperature ranges− storage− medium
-30 .... 80 °C-10 .... 50 °C
Weight− sensor− cable− additional weight
approx. 0.18 kgapprox. 0.08 kg/mapprox. 0.5 kg
approx. 0.2 kg
1) For model 3230 only of F.S. = of full scale value2) Special signal for mains independent operation, for ranges ≥ 0...0.25 bar3) Terminal point adjustment according to DIN 16 086, including linearity and hysteresis
(calibrated in vertical installation position)4) Including pressure connection and diaphragm5) Up to max. 10 bar6) 0.4 % for measuring ranges 0...0.1 and 0...0.16 bar7) Declaration of conformity on request
DE 725c
p. 3/4
Dimensions (mm)Model 3233 Model 3230
Option: PTFE cable10
0
18
27
10
G1/2B
115
*
18
27
10
G1/2B
115
18
27
10
G1/2B
* with lithening protection length + 30mm
Electrical connection
Two wire system Three wire system PT 100, four wire system
with cable outlet with cable outletUB / S+
OV / S-
brown
green
blueshield
E-024
0V / S-
UB
S+
brown
green
white
blueschield
E-026
grayredt
blackyellow
E-065
Connection table for cable outlet4...20 mA(2 - wire)
0...10VDC(3 - wire)
Supply: UB+ brown brownSupply: 0V green greenSignal: S+ - whiteSignal: S- - greenShield blue blue
DE 725c
p. 4/4
Accessoires
Art. No. DescriptionZM53.001.003 Filter element for capillary tubeZM53.001.002 Cable clipZM53.001.001 Additional weightZM53.001.004 Junction box (protection type IP 54)
cable
filter
shrink hose
filter element
junction box
cable clip
additional weight
Order details1. Model2. Measuring range3. Output signal4. Cable length5. Options
Druck Temperatur Kraft
tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Export salesF. ++49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 726c Model : 3269
p. 1/5
Pressure Sensors for food industrywith frontflush diaphragmfor gauge and absolute pressure
accuracy 0.5 %
standard output: 4...20 mA; 2-wire-systemor 0...10 VDC; 3-wire-system
Description
Tecsis pressure sensors for the food industryfulfill the special requirements of pressureconnections in food industry, and they offer awide range of different connections.
The combination of pressure sensor and specialconnection result in a better performance of theinstrument. It can replace a necessary chemicalseal systeme. All wetted parts are made ofstainless steel and completely welded. Therobust case is also made of stainless steel. Itprovides a protection type of at least IP65. Thepressure transmitting liquid is approved by FDA.
The pressure sensor model 3269 is designed toensure the surfaces exposed to the process iscrack or crevice free according to the hygienicrescriptions. Pressure connections with Clamp-connector or according to DIN 11851respectively Varivent connections are available.
An integrated cooling element guaranteestemperature ranges up to 150 °C.
Features
O Compact design
O Corrosion resistant stainless steel versionO High overload capacityO Special pressure connection directly on the
sensorO Aseptic pressure connectionO Wetted parts 14435O Certificate according to EHEDG and 3A
sanitary standards
Measuring ranges
Gauge pressureNegative -1...0 barpositive 0...0.25 bar up to 0...25 barAbsolute pressure 0...0.25 bar up to 0...16 bar
Application
Dairies and breweries,Food industry,pharmaceutical industry,sterilizers.
DE 726c
p. 2/5
Technical data
Model 3269Pressure type positive gauge pressure
absolute pressureOutput signal 4...20 mA - 2-wire system
0...20 mA - 3-wire system0...10 VDC - 3-wire system
Pressure ranges 1) 0.25 0.4 0.6 1.0 2.5 4 6 10 16 25Overload limit 2 2 4 5 10 17 35 35 80 80Accuracy % of F.S. 2) 0.5Repeatability < ± 0.05 % of F.S.Stability per year < ± 0.2 % of F.S. in rated conditionsCase stainless steel 1.4571Pressure connection Tri-Clamp 1 1⁄2 “;
Option: Tri-Clamp 2“Union nut DIN 11851 DN 25; DN40; DN50.Union nut DIN 11864-1 DN40; DN50.Clamp ISO 2852 DN 33,7; DN 38; DN 40; DN 51.Clamp DIN 32676 DN 32; DN 40; DN 50.Varivent connection form F; form N.
Wetted parts stainless steel 1.4435Electrical connection rectangular plug form A with junction box (DIN EN 175301-803 A)
round connector M12x1, 4-pincable outlet with 10 m cable
Power supply / Load- 4...20 mA- 0...20 mA- 0...10 V
10...30 VDC10...30 VDC14...30 VDC
RA[Ω ] ≤ (UB[V]-10V) / 0.02ARA[Ω ] ≤ (UB[V]-3V) / 0.02A> 10 kOhm
Power consumption- 4...20 mA- 0...20 mA- 0...10 V
Signal currentsignal current + 4 mA8 mA
Temp. comp. range 0....80°CAverage TC of− zero point 3)− span
< ± 0.2 % /10 K< ± 0.2 % /10 K
Adjustability 4) Zero point and full scale up to ± 10 %Response time < 10 ms ( from 10 % to 90 % of f.s.)Protection type IP 65 to EN 60529/IEC 529
IP 67 for M12x1 connectorIP 68 for cable outlet 4)
Emission 5) Acc. to EN 61326Interference 5) acc. to EN 61326Electrical protection type Polarity, overvoltage and short-circuit protectionTemperature ranges- Storage- Medium- Ambient
-40 .... 100 °C-20 .... 150 °C-20 .... 80 °C
Weight approx. 0.2 kg
of F.S. = of full scale value1) Absolute pressure 0... 2.5 bar to 0... 16 bar2) Terminal point adjustment according to DIN 16086 incl. linearity and hysteresis. Installation position vertical.3) < 0.4 % /10K for pressure range 0... 0.25 bar
< 0.25 % /10K for pressure ranges0... 0.4 bar4) no adjustability possible for cable outlet5) Declaration of conformity on request
DE 726c
p. 3/5
Dimensions (mm)
Case
rectangular plug form A round connector M12x1 cable outlet
Pressure connection
clamp DIN 11851 DIN 11864-1 varivent
Dimensions (mm)Pressure connection
Nominal diameterDN
(mm/in.)D G
1 1⁄2 “ 50Tri-Clamp2 “ 64
DN 32 50DN 40 50
DIN 32676
DN 50 64DN 33,7 50DN 38 50DN 40 64
Clamp
ISO 2852
DN 51 64DN 25 44 Rd 52 x 1/6DN 40 56 Rd 65 x 1/6
Union nut DIN 11851 with conical coupling, for tubes toDIN 11850
DN 50 68.5 Rd 78 x 1/6DN 40 54.9 Rd 65 x 1/6Union nut DIN 11864-1 with liner form A, for tubes to
DIN 11850 DN 50 66.9 Rd 78 x 1/6form F DN 25/32 50Variventform N DN 40/50 68
DE 726c
p. 4/5
Electrical connectionTwo-wire system
rectangular plug form A round connector M12x1UB / S+
0V / S-
13
2
E-001
UB / S+
0V / S-
1 2
4 3
E-033
cable outlet
UB / S+
0V / S-
braun
grün
Three-wire system
rectangular plug form A round connector M12x1UB
0V / S-
S+
E-002
UB
0V / S-
S+
41
32
E-034
cable outlet
0V / S-
UB
S+
braun
grün
weiß
Connection table for DIN plug or cable outlet4...20 mA(2 - wire)
0...10VDC(3 - wire)
Supply: +UB 1 brown 1 brownSupply: 0V 2 green 2 greenSignal: +S - - 3 whiteSignal: -S - - 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
DE 728 c Baureihe: 2850, 2851, 2860, 2861page 1/4
Pressure Transducerwith local indicationall stainless steelaccording to DIN 16 006nominal size 100
with or without filling
Description
Standard system pressure gauges and the safetyversion to EN 837-1 / S3 meet the specialrequirements of the chemical and relatedindustries with regard to safety, reliability,corrosion resistance and robustness.
The special feature of tranducers with localdisplay is an analog display of the measuredvalue on side and the output of a correspondingelectrical standard signal (mostly 4...20mA) fortransmitting the measured value. A pressurerelated mechanical measuring element(diaphragm or Bourdon tube) provides the localdisplay and simultaneously controls a magnetic-field dependent sensor. The integratedelectronics supply the standardized signal.
Gauges with liquid filling provide a practicallyvibration-free display if pressure surges ormechanical vibrations arise and have aparticularly long service life.
For more difficult measuring tasks (e.g. hydro-static column), two potentiometers enable thezero point and measuring range to be set.
Pressure sensores Industrial Heavy Duty meetthe electromagnetic compatibility (EMC) require-ments of EN 61326.
Features
O Local display
O Display accuracy:up to 0...0.4 bar, class 1.6from 0...0.6 bar, class 1.0
O Safety version to EN 837-1 / S3
O Corrosion resistant stainless steel design
O Standard signals: 4...20mA, 2-wire;0...20 mA, 3-wire
O Liquid filling of case to provide damping of measuring system.
Measuring ranges
Gauge pressure
negative - 1 ... 0 bar to -0.06 ... 0 bar
positive 0 ...0.06 bar to 0 ... 1000 bar
Applications
Chemical and petrochemical industries,Pharmaceutical and cosmetics industries,Food and beverage industries.
DE 728 cpage 2/4
Technical data
Models 2850 2851 2860 2861 OptionsNominal size 100Liquid filling none siliconoil none siliconoilPressure type negative or positive gauge pressure negative and
positive gaugepressure
Output signal 0 ... 20 mA3-wire system
4 ... 20 mA2-wire system
intrinsically safeversion on request
Accuracy− display
− output signal 1)
≤ 0...0.4 bar class 1.6≥ 0...0.6 bar class 1.0≤ 0...0.4 bar ± 1.0 % of F.S.≥ 0...0.6 bar ± 0.8 % of F.S.
Ranges accord. to EN 2) 0 ... 0.06 barto
0 ... 1000 bar
other rangeson request
Overload limit− constant load− alternating load− short time load
1.0-fold0.9-fold1.3-fold (< 0.6 bar 10-fold)
Case stainless steel 1.4301Pressure connection G1⁄2 B to EN 837-1 /7.3 G1⁄4 B; 1⁄2 NPT;
1⁄4 NPTWetted parts stainless steel 1.4571Electrical connection junction box with PG 13.5Power supply− influence of power
supply− permissible residual
ripple
10 ... 30 VDC≤ 0.1% of F.S / 10 V
≤ 10% ss
Power consuption current signal +15 mA current signalLoad RA [Ω ] ≤ (UB [V] - 10 V) / 0.02 ATemp. compens. range -25 ... 60 °CTemperature influence ± 0.3 % / 10 K on zero and spanAdjustiblity− electrical− mechanical
up to ± 5 % of F.S. (zero and span)approx. 5 % of F.S. (only for ranges ≤ 0...400 mbar)
Response time approx. 50 msProtection types 3) IP 54 IP 65 IP 54 IP 65Emission 4) to EN 61326Interference 4) to EN 61326Electr. protection types polarity and overvoltage protectionTemperature ranges− medium− ambient
- 25 ... 100°C- 25 ... 60°C
Weight 0.8 kg 1.5 kg 0.8 kg 1.5 kgof F.S. = of full scale value
1)Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis
2)Liquid filling from 0 ... 0.6 bar
3)According to EN 60529 / IEC 529
4)Declaration of conformity on request
DE 728 cpage 3/4
Dimensions (mm)10
1
43.5
62
SW 22
94
97
49
87
22.5
3117.3
Pg 13.5
99
Verstellmöglischkeit / adjusment
Position of potentiometers
The potentiometer can be reached by unscrewing the screws of the case.
SP NP
S potentiometer for span adjustmentZ potentiometer for zero point adjustment
DE 728 cpage 4/4
Electrical connection
two-wire system
UB / S+
0V / S-
Test +
Test -
43
12
E-045
Three-wire system
UB
0V / S-
Test +
S+ / Test -
43
12
E-048
Order details1. Model2. Measuring range3. Output signal4. Options
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models: 1999tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 733c
p. 1/4
Indicator with Microprocessor4-digit LED display
with and without limit contacts
Type: Attachable indicatorPanel mount case
Description
Indicators are electronic devices designed fordigital display of sensor signals.
The indicators can be set to the desiredmeasuring range on site by program-control. Theprogramming is done via flushmounted keysbelow the front cover.
A programmable damper ensures a precisereadability of the indicating value in case ofpulsation or if pressure peaks occur.
Attachable indicatorThe attachable indicator provides an idealsolution for a local indication with simultaneoussignal transmission. Due to its universalprogrammability and simple mounting theattachable indicator can be retrofitted even topressure sensors which are already in use.
Panel mount caseThe multitude of feasable input signals and thecompact design make the indicator suitable forvarious applications.
Limit contacts provide information on the statusof the process being monitored.
To transmit measuring values to a PC a digitalinterface RS 485 can be provided.
Features
O freely programmable by microprocessorO range setting on site, no external calibration
equipment needed
Attachable indicatorO for pressure senors with 4...20 mA output
and right angle plug according to DIN 43650O protection type IP65O simple handling
Panel mount caseO input freely selectable: 0/4...20 mA,
0...10 V, 0...1 VO two limit contacts: function and hysteresis
freely programmableO option: digital interface RS485O compact design
Applications
chemical and petrochemical industry,pharmaceutical industry,food and beverage,machine tool and injection moulding,presses,development and testing.
DE 733c
p. 2/4
Technical data
Model 1999.100 1999.300Type Attachable indicator Panel mount caseDisplay 7 segment LED-display 7 segment LED-display− height 10 mm 10 mm− range -1999...9999 (4 digits) -1999...9999 (4 digits)− accuracy 0.2% of F.S. ± 1 digit 0.5% of F.S. ± 1 digit− conversion rate 5 /sec. 2-3 /sec.Measuring ranges program controlled program controlledInput 4...20 mA, 2-wire selectable: 4...20 mA
0...20 mA0...10 VDC0...1 VDC
− channels 1− input resistance for current input 50 Ω
for voltage input 0...1 V 30 kΩfor voltage input 0...10 V 300 kΩ
− temperature influence ≤ 0.1% of F.S./10K ≤ 0.25% of F.S./10KFilter function selectable in 3 steps 2/3 sec. selectableLimit contacts 2 transistor switching outputs - n-switching− function limit contatcs as Hi or Low programmable by
selecting the hysteresis− switching point
− hysteresis
program controlled adjustablewithin the adjusted display rangeprogram controlled adjustablewithin the whole display range
− load 30 VDC; 50 mA− response time adjustable 0...99 sec.Power supply sensor is supplied by the 4...20 mA-loop 9...28 VDC− power consumption max. 40 mA max. 60 mA at 12 VDC− voltage drop 3 VElectrical connection sensor with 4...20 mA output and
plug according to DIN 43650screw terminals, max. 1.5 mm²
Temperature ranges− operation 0...50 °C 0...50 °CProtection type IP 65 front panel IP54Case dimensions: 50x50x35 see drawings for dimensions− sectional view of
switchboard21.7+0.5 x 45+0.5 (HxW)
− material ABS glass fibre strengthend Noryl− window Polycarbonate Polycarbonate− mounting spring clampWeight approx. 0.08 kg approx. 0.05 kg
Options
Model 1999.100 1999.300Digital output RS 485Protection type front panel IP 65
of F.S. = of full scale
DE 733c
p. 3/4
Operating and connection elements
Front view below cover
Panel mount case
A LED-displayB function key 1C function key 2D function key 3
Attachable indicator
Dimensions (mm)
Panel mount case
Attachable indicator
DE 733c
p. 4/4
Configuration of connection terminals (Panel mount case)
Connection terminal1 mains supply +Uv (9 to 28 VDC)2 mains supply -Uv / GND3 transistor output 14 transistor output 25 frequency input / counter input6 input mA7 input GND8 input 1V9 input 10V10 digital output RS485 A11 digital output RS485 B
Connection examples (Panel mount case)
Signal input4...20 mA - 2-wire 0/4...20 mA - 3-wire
9-28 VDC1
2
6
Sensor
Indicator
Uv+UV-
+-
9-28 VDC1
2
6
Sensor
Indicator
Uv+UV-
+-
S
0...1/10 V - 3-wire 0...1/10 V - 4-wire9-28 VDC
1
2
7
Sensor
Indicator
Uv+UV-
+-
S8
9 10V
1V
9-28 VDC1
2
7
Sensor
Indicator
Uv+UV-
+-
S+8
9 10V
1V
S -
Order details1. Model2. Options
DE 735 b Model: 3923Seite 1/2
Hand-Held Instrument „Manoport“for low pressure and differential pressureaccuracy 1 % resp. 0.6 %
31⁄2 digit LCD display
Descripton
The hand-held instrument „Manoport“, ispracticaly useful for measuring low differentialpressure. If the second line to the atmospherestays open, positiv as well as negative overpresure can be measured.
It is mainly applied with the field of heating, aircondition, ventilation, filter, anti-dust and medicaltechnologie.
The measuring ranges are scaled between0...2.5 mbar to 0...1000 mbar for themeasurement of gas and air. For absolutepressure the measuring range 700...1100 mbar isalso available as an alternative.
The piezoresistive measuring elementguarantees a high degree of reliability.
A carriying case can be obtained as an option.
Features
O Measuring range from 2.5 mbar to 1000mbar
O LCD-Display with 12.7 mm heightO Independent from stationary energie supply
due to batteryO High reliabilityO Differential pressure (including positive and
negative gauge pressure)
Measuring rangesDifferential pressure0...2.5 mbar to 0...1000 mbar
ApplicationsHeating, air condition, ventilation,
Filter, anti-dust,
Medical technologie.
DE 735 bSeite 2/2
Technical Data
Model 3923Pressure type Differential presure (including positive and negative gauge
pressure)Measuring range [mbar] 2.5 5 10 25 50 100 250 500 1000Overload limit [mbar] 250 250 250 375 750 1125 750 1500 3000Repeatability [% of F.S.] 0.3 0.2 0.1Accuracy [% of F.S.] 1 0.6Sensor element PiezoresistiveHysteresis [% of F.S.] 0.1Stability per year [% of F.S.] 2 0.5 0.1Pressure connection 2 plugs for 4mm tubeMedium for dry non-agresive gases onlyPower supply 9 V block batterieTemp. compens. range 0.... 50°CTemperature influence [% of F.S.] 2.5 1.0 0.7Response time 1 msProtection Type IP 54Operation temperatur 0 .... 50 °CCase Plastic.Weight ca. 0.19 kg
of F.S. = of full scale value
OptionAnalog output 0 ... 1 VDC ( Load > 2K )
Accessories
Art. Nr. DescriptionZM49.090.017 Carriying case, plastic, single
Dimensions (mm)40
T=31
84
14,3
170
Order details1. Models2. Measuring range3. Options
Technologies for Sensors Indicators and Systems | Pressure | Temperature | Force
tecsis GmbHAn der Sandelmühle 13D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Hand-Held Pressure Measuring Instrument„Manoport“with microprocessorfor external pressure sensors
accuracy 0.25% and 0.5%
4 digit LCD display
DescriptionThe hand-held pressure measuring instrument „Mano-port“ is a handy digital indicator for all types of pressuremeasurements.
The external pressure sensor can be obtained for measu-ring ranges from 0 . . . 0.1 bar up to 0 . . . 4000 bar. Sen-sors are available for both gauge and absolute pressure.
All wetted parts are made of stainless steel and are high-ly resistant against corrosive gases and fluids. For vis-cous or crystallizing media front-flush diaphragms areavailable, avoiding dead pressure zones.
The sensors are automatically detected by the instrumentand set up their nominal measuring range including deci-mal point. To indicate variable pressure signals the instru-ment provides a measured value memory (HOLD) and apeak value memory (MIN and MAX). The reading can bedisplayed in a great variety of different units.
Depending on the process requirements, sensors withaccuracies better than ± 0.25% respectively ± 0.5% of fullscale value can be applied.
The built-in battery ensures independence from a stationarypower supply and avoids any injury risk by mains voltage.
The hand-held pressure measuring instrument has a ro-bust water protected case and can be used in nearly anyenvironment.
Features Suitable for universal applications (external
pressure sensors)
Independant of stationary power supply(battery)
Low weight
Auto-detection of measuring range
Selectable units
Adjustable zero value
High resistance against agressive media
High degree of protection (IP 67)
Peak value memory (MIN and MAX) and actual value memory (HOLD)
Measuring rangesGauge pressurepositive 0 . . . 0.1 to 0 . . . 4000 barnegative -1 . . . 0 to -0.1 . . . 0 barAbsolute pressure 0 . . . 0.25 to 0 . . . 16 bar
ApplicationsService and repair,process and gas pressure measurements,hydraulics, pneumatics.
Model: 3904
DE 7 36 b
P. 1 / 4
3904.300.0017-segment-LCD-display, 10.5 mm high± 9999± 0.06% of F. S. ± 1 digit (including: linearity and hysteresis)± 0.1% of F. S.4 / s; 1/4 s in filter mode
automatical set up by the connected sensorselectable: bar, mbar, psi, inH2O, inHg, mmHg, Torr, Pa, kPa,mH2O, mmH2O, kg / cm2
programmable8 pin DIN screw connectorHOLD-mode, saves the actual pressure valueMAX-, MIN-mode, saves the maximum and minimum pressure value9 V monoblock battery;approx. 20 hrs. with zinc carbon batteryapprox. 100 hrs. with alkaline batteryIP 67 EN 60 529, IEC 529
-25 °C to +50 °C-25 °C to +70 °C0.1% / 10 K; of zero and spanplastic grey; 173 x 82.5 / 69 x 28 (l x w x h)approx. 320 g including battery
Technical data digital indicatorModelDisplay
- Range 1)- Accuracy- Repeatability- Sample rate
Measuring range 1)- Adjustment- Units
Zero value adjustmentSensor connectionActual value memoryPeak value memory
Power supply- Battery life
Degree of protectionTemperature range
- Operation- Ambient
Temperature influenceCaseWeight
1) depending on the connected sensor of F. S. = of full scale value
AccessoriesArticle no. DescriptionCZ60.000.001 rubber protection capZE53.001.002 connecting cable for sensors 1.5 m (IP 40)ZM49.090.009 carrying case, plastic, seperate
Recommended basic service cases:Digital Indicator Model 3904.300.001,Connecting cable for pressure sensor,Carrying case
DE 7 36 b
P. 2 / 4
Dimensions (mm)
Operating and connection elementsA l on / off-keyB ZERO zero value adjustmentC SCL unit selectionD HOLD hold modeE FILT filter modeF REC record modeG sensor connection
DE 7 36 b
P. 3 / 4
tecsis GmbHAn der Sandelmühle 13D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Modifications reserved
Technical data external pressure sensorsModelTypePressure type
Accuracy 1)Ranges accord. to EN
Sensor element
RepeatabilityHysteresisStability per yearCasePressure connection
Wetted partsOver load limitElectrical connectionTemp. comp. rangeTemperature influence
Response timeProtection typeTemperature ranges
- storage- medium- ambient
Weight
3392 3393 3397 3398internal diaphragm front flush diaphragmneg. or pos. absolute neg. or pos. absolutegauge pressure pressure gauge pressure pressure0.5% of F. S.0 . . . 0.1 bar 0 . . . 0.25 bar 0 . . . 0.1 bar 0 . . . 0.25 barto to to to0 . . . 4000 bar 0 . . . 16 bar 0 . . . 600 bar 0 . . . 16 barpiezoresistive; piezoresistive piezoresistive; piezoresistive> 16 bar thin > 16 bar thinfilm film≤ ± 0.05% of F. S.≤ ± 0.1% of F. S.≤ 0.2% of F. S. at rated conditionsStainless steel 1.4301G 1/2 B according to DIN 16 288 G 1/2 B front flush diaphragm,≥ 2500 bar M 16 x 1.5 ≤ 2.5 bar G 1 BStainless steel 1.4571 and 1.4542≤ 16 bar 3.5 x; ≤ 600 bar 2 x; > 600 bar 1.5 x; 1600 bar 1.2 x8-pole DIN screw connector0 . . . +80 °C± 0.2% / 10 K, at zero and span± 0.4% / 10 K for pressure ranges < 0.16 bar≤ 1 ms (within 10% to 90% of F. S.)IP 65 EN 60 529, IEC 529
-40 . . . +100 °C-30 . . . +100 °C-10 . . . + 80 °Capprox. 0.15 kg
Options
negative and positivegauge pressure0.25% of F. S.
other connections on request
1) Terminal point adjustment according to DIN 16 086; includes linearity and hysteresis of F. S. = of full scale value
Dimensions (mm)Case Pressure connection
internal pressure diaphragm
front flush pressure diaphragm
Order details1. Model instrument / 2. Model external sensor / 3. Ranges external sensor / 4. Options
DE 7 36 b
P. 4 / 4
DE 737 b Model: 3922page 1/3
Hand-Held Pressure Measuring Instrument"Manoport"with microprocessorwith integrated pressure sensor
4 digit LCD display
Description
The hand-held pressure measuring instrument"Manoport" is a handy digital indicator for gasand air pressure measurements. The "Manoport"is equiped with an integrated differential pressuresensor which can be obtained for four differentpressure ranges between 140 mbar and 6900mbar. To measure positive or negative gaugepressure leave the second line open toatmospheric pressure.
To indicate variable pressure signals theinstrument provides a measured value memory(HOLD) and a peak value memory (MIN andMAX). The filter mode allows to stable thereading. The accuracy can be increased byadjusting the zero value. The reading can bedisplayed in a great variety of different units. Theinstrument provides an over reading indication,reports over range pressure as well as lowbattery.
The built-in battery ensures independence from astationary power supply and avoids any injuryrisk by mains voltage.
The hand-held pressure measuring instrumenthas a robust water protected case and can beused in nearly any environment.
The hand-held pressure measuring instrument"Manoport" is delivered with all tubes andconnections.
For pressure measurement in fluids a specialversion can be obtained.
Features
O High accuracy
O Independent of stationary power supply(battery)
O Low weight
O Selectable units
O Adjustable zero value
O High degree of protection (IP67)
O Peak value memory (MIN and MAX) andactual value memory (HOLD)
O Differential pressure (including positive andnegative gauge pressure)
Measuring ranges
Differential pressure: 0 ... 140 mbar0 ... 350 mbar0 ... 2000 mbar0 ... 6900 mbar
Applications
Service and repair,process- and gas pressure measurement,filters, air conditioning,laboratories.
DE 737 bpage 2/3
Technical Data
Model 3922 OptionsDisplay 7-segment-LCD-display, 10.5 mm high− Range ± 9999− Accuracy ± 0.2% of F.S. ± 1 digit (including: linearity and hysteresis)− Repeatability ± 0.1% of F.S.− Sample rate 4 /s; 1/4s in filter modeMeasuring range− mbar ranges 0...140 mbar,
0...350 mbar,0...2000 mbar,0...6900 mbar
− Units selectable: mbar, psi, inH2O, inHg, mmHg, Torr, Pa, kPa,mmH2O, cmH2O, kg/cm2
Pressure type differential pressure (including negative and positive gaugepressure)
Over pressure protection 3x of F.S., max. 13 barMedia dry, non agressive gases fluidsPressure connection G1/8 femaleTemperature ranges− Operation 0 °C bis 50 °C;
10 to 90% humidity, non condensatingTemperature influence 0.1% / 10K; at zero and spanZero value adjustment programmableMeasured value memory HOLD-mode, holds the actual valuePeak value memory MAX-, MIN-mode, saves the maximum and minimum valuePower supply 9 V monoblock battery;
battery life approx. 125 hrs. with alkali-mangan-batteryProtection type IP 67 EN 60 529, IEC 529Case plastic grey; 176.5 x 82.5/69 x 28 (lxwXh)Weight approx. 320g including battery
of F.S. = of full scale value
Accessories
Article no. DescriptionCZ60.000.001 Rubber protection capZM49.090.009 Carrying case, plastic , seperateZM25.001.001 Tube quick coupling for 4mm tubeZM25.001.002 Tube quick coupling for 6mm tubeZM25.001.003 Tube quick coupling for 8mm tube
Order details:1. Model2. Measuring range3. Options
DE 737 bpage 3/3
Dimensions (mm)
A B
C D
E F
G H
Operating and connection elementsA on / off KeyB ZERO zero value adjustmentC SCL unit selectionD HOLD hold-modeE FILT filter-modeF REC record-modeG positive pressure lineH negative pressure line
DE 739 e model: 3131, 3132, 3133, 3134page 1/4
Electronic Pressure Switchwith internal or front flush diaphragmfor gauge pressure and absolute pressure
1 or 2, NO or NC
output p- or n-switching
Description
tecsis electronic pressure switches are based onthe sensor elements which have beenexperienced for years in the field of pressuresensors. The signal conditioning circuit providesone or two digital outputs .
As a standard, the pressure switch is factoryadjusted according to the customersrequirements. The programming can also bedone by the customer himself with an additionalprogramming module. The setting of theswitching function respectively the setting of theswitching window, the setpoint and the switchinghysteresis can be made completely digital bymeans of a PC running under Windows.
Their accuracy, reliability, resistance to corrosionand mechanical load rating make them suitablefor all switching tasks.
The measuring ranges, graded in accordance toEN, range from 0.25 bar to 1000 bar. The caseand wetted parts are of stainless steel and areresistant to chemically aggressive media. Thepressure connection and the sensor element arecompletely welded, making the measuring systeminsensitive against mechanical shock andvibrations.
The electronic pressure switches meet theelectronic magnetic compatibility (EMC)requirements according to EN 61326.
Features
O Measuring ranges from 0.25 bar to 1000 bar
O Finely adjustable selection of nominalpressure ranges according to EN
O Corrosion resistant stainless steel versionO Overload protectionO 1 or 2, NO or NC contactsO Programmable switching points
Measuring ranges
Gauge pressurenegative -1...0 bar to -0.25...0 barpositive 0...0.25 bar to 0...1000 barAbsolute pressure 0...0.25 bar to 0...16 bar
Applications
Process and chemical engineering,Hydraulics and pneumatics,Plant and apperatus design
DE 739 epage 2/4
Technical data
Model 3131 3133 3132 3134 OptionType internal diaphragm front flush diaphragmRanges acc. to EN 0 ... 0.25 bar
to0 ... 1000 bar
0 ... 0.25 barto
0 ... 16 bar
0 ... 0.25 barto
0 ... 600 bar
0 ... 0.25 barto
0 ... 16 barPressure type positive gauge
pressureabsolutepressure
positive gaugepressure
absolutepressure
neg. and/or pos.gauge pressure
Overload limit ≤ 16 bar 3.5-times≤ 600 bar 2-times> 600 bar 1.5-times
Pressure connection G 1⁄2 B G 1⁄2 B front flush(≤ 0...1.6 bar G 1 B )
G1⁄4 B, 1⁄4 NPT, 1⁄2 NPT1)
Wetted parts stainless steel 1.4571 and 1.4542− O-ring - NBR VitonCase stainless steel 1.4571Switching function 1 or 2 switching outputs
NO, NC or switching windowp- or n-switching
Adjustment− Switch. point / window− Hysteresis− Damping
0 ... 100 % of F.S.1 ... 99 % of F.S.0 ... 500 ms
Accuracy ≤ 1% of F.S. (terminal point adjustment)Repeatability ≤ 0.25% of F.S.Stability per year ≤ ± 0.2 % of F.S. in rated conditionsPower supply 10...30 VDC, (>12 VDC for programming mode)Contact rating− 1 switching output
− 2 switching outputs
p-switching 4 ADC (max. 30 VDC)n-switching 0.3 ADC (max. 30 VDC)p-switching 2 ADC (max. 30 VDC)n-switching 0.3 ADC (max. 30 VDC)
Circuit time− p-switching− n-switching
≤ 6 ms≤ 10 ms
Temp. compens. range 0.... 80°CTemperature influence ± 0.2 % /10 K, for zero and spanTemperature ranges− storage− medium− ambient
-40 .... 100 °C-30 .... 100 °C-20 .... 80 °C
media temperature-40 ... 125 °C
Electrical connection− 1 switching output− 2 switching outputs
plug to DIN 43650 with junction boxround connector M12x1 (5-pin)
cable outlet with 1mcable
Protection IP 65 for DIN plugIP 67 for round connector
IP 67 with cableoutlet
Emission 2) according to EN 61326Interference 2) according to EN 61326Electrical protection polarity-, overload- and short-circuit-protectionWeight approx. 0.20 kg
of F.S. = of full scale value1) only for model 3131 and 31332) declaration of conformity on request
DE 739 epage 3/4
Dimensions (mm)
Case
plug to DIN 43 650 connector M12x1 cable outlet
max
. 105
75
48
2775
2787
75
27
130
Pressure connection
G 1⁄2 B G 1⁄2 B G 1 B
328,5
17,5
20
8,5
3
27
G1/2B
6
18,5 x 23,9 x 1,5
15 x 2
27
31
20,5
10
18 -0,1
G1/2B
29,7 x 35,7 x 2,0
26 x 2
41
G1 B
3120
,510
,5
30 -0,1
10
internal diaphragm front flush diaphragm
Screw-in aperture resp.weld-on adapter
G 1⁄2 G 1⁄2 G 1
24,5
+1
19-0
,5
Min
. 14.
5
7
G1/2(DIN 16288)
A0.1
A
50
21.3-0,2
G1/2
19.4+0.1
21
18.2+0.1
15-0
.2
Min
.10.
5
0.1 A
A
50
33.5 -0.2
G130.5 +0.1
30.1 +0.1
2115-0
.2
Min
.10.
5
internal diaphragm front flush diaphragm
DE 739 epage 4/4
Electrical connection
DIN 43 650 plug
1 switching outputp-switching n-switching
UB
0V
SA1 13
2
E-063
E-064
UB
0V
SA1
13
2
round connector M12x1
1 switching outputp-switching n-switching
UB
0V
1 2
4 35
S1
E-038E-039
UB
0V
1 2
4 35
S1
2 switching outputp-switching n-switching
E-040
UB
0V
1 2
4 35
S1
S2
E-041
UB
0V
1 2
4 35
S1
S2
Connection tableplug
DIN 43650connector
M12x1cable outlet
Power supply: UB+ 1 1 brownPower supply: 0V 2 3 greenSwitching output: SA1 3 4 whiteSwitching output: SA2 - 5 yellow
Order detailsPlease use the check list for pressure switches.
DE 740 d Model: 3140, 3141page 1/4
Electronic Pressure Switch „MagSwitch“on hall effect principle
1 or 2 contactssemiconductor relay p-switching or n-switching
Description
The new electronic pressure switches„MagSwitch“ on hall effect principle are applicablein all fields that require the reliability of semi-conductor relays. This switching principle withoutmechanical contact ensures a long working life.
By means of an elastic measuring element andby applying the hall effect a switching output isgenerated at a given pressure value. The switchis available with a NO or NC contact.
The switching points can be set on site viathe turning screws.
The pressure ranges from 0.1 bar up to 600 bargraded in accordance with EN offer a wide rangeof possible applications. The overload limit up to10 bar is 5-times, at 10 bar 4-times and above 10bar 2-times the nominal pressure.
The variety of pressure connections allows to usethe eletronic pressure switch „MagSwitch“ formany different applications. Special connectionsfor refrigeration applications are available. Quickcouplings for hoses can be delivered on request.
The electrical connection is made through a4-pin round connector (M 12x1) or a cable outlet.
Features
O switching point adjustable on siteO pressure ranges from 0.1 bar to 600 bar
O finely graded selection of nominal pressureranges according to EN
O high switching security by solid state relaisO 1 or 2 setpointsO NO or NC contact functionO integrated LED for indicationO suitable for direct connection to PLC inputsO case: brass respectively aluminium anodizedO variety of process connections
Pressure ranges
gauge pressurepositive 0...0.1 bar to 0...600 barnegative -1...0 bar to -0.1...0 bar
Applications
Mechanical engineering,Apparatus construction,Hydraulics and fluid technologyRefrigeration systems.
DE 740 dpage2/4
Technical data
Model 3140 3141 OptionRanges according to EN 0 ... 0.1 bar
to0 ... 25 bar
0 ... 60 barto
0 ... 600 bar
other ranges onrequest
Pressure type positive gauge pressure neg., neg. and pos.gauge pressure
Overload limit ≤ 10 bar 5x10 bar 4x≤ 25 bar 2x
2x
Operations 1 106
Pressure connection 1) G 1⁄4, G 1/8, 1⁄4 NPTM10x1, M12x1.5
G 1⁄4, G 1⁄4 female,G 1⁄2
other on request
Materials− measuring element− pressure connection
nickel or copper alloybrass,
stainless steel 1.4571brass,
− case brass aluminium anodized− top plastic plastic
wetted parts:stainless steel
Switching function 2) 1 NO, 1 NC, 2 NO, 2NC or 1 NO + 1 NC contactp-switching or n switching
Adjustability− switching point
via turning screw on site5 ... 100% of F.S. 3)
Repeatability < 1% of F.S.Switching hysteresis ≤ 5% of F.S. 4) other on requestPower supply 10...30 VDC 5)Contact rating max. 100 mA (max. 30 VDC) other on requestTemperature comp. rangeTemperature influence
0...80°C0.4 % / 10K
Temperature ranges− storage− media− ambient
-30 ... 80°C-20 ... 80°C-20 ... 80°C
-40 °C ... 110 °C
Electr. connection round connector M12x1 (4-pin),cable outlet with 1.5 m cable
Protection type IP65 according to EN60529IP67 for cable outlet
Emission according to EN 61326Interference according to EN 61326Electrical protection types reverse polarity and overvoltage protectionWeight approx. 0.09kg approx. 0.27kg
1) G1/4 without spigot. of F.S. = of full scale value2) At increasing pressure.3) 10...100% of F.S. for ranges 16 and 25 bar4) ≤ 10% of F.S. for ranges 16 and 25 bar5) Influence of the power supply (∆UB = 10 V) < 0.3% of F.S.
DE 740 dpage 3/4
Dimensions (mm)Case: Model 3140
round connector M12x1 cable outlet
31,8
G1/4 B
SW32
60.4
47.4
13+0
.5
31,8
G1/4 B
SW32
62
47.4
13+0
.5
Case: Model 3141
round connector M12x1 cable outlet
36
G1/4 B
49
71
+0,5
13+0
.5
36
G1/4 B
51
71
+0,5
13+0
.5
DE 740 dpage4/4
Electrical connection
round connector M12x1 (4-pin)1 switching outputP-switching
2 switching outputP-switching
UB
S1
1
0V
2
34
E-042
UB
S1
1
0V
2
34
S2
E-043
n-switching n-switchingUB
S11
0V
2
34
E-042.1
E-043.1
UB
0V S1
S2
1 2
34
cable outlet1 switching outputP-switching
2 switching outputP-switching
UB
S1
0V
brown
black
blue
E-028
UB
S1
0V
S2brown
black
blue
white
E-030
n-switching n-switchingUB
S1
0V
E-028.1
brown
black
blue
UB
S10V
S2
E-030.1
brown
black
blue
white
Order detailsPlease use our check list for pressure switches.
Technologies for Sensors Indicators and Systems | Pressure | Temperature | Force
tecsis GmbHAn der Sandelmühle 13D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Pressure SwitchPressure Gauge ND 40 / 50 / 631 NC or NO
DescriptionPressure switches with NO or NC contacts are the perfectchoise if both an electrical signal at a given pressure va-lue and an analogue indication are required.
The measuring principle of the pressure switch is the sa-me as used for pressure gauges according to EN 562respectively pressure gauges for special safety accordingto EN 837-1 „S“ with an accuracy class 2.5. The excellentswitching reliability and long service life is guaranteed bya gold plated, self-cleaning magnetic snap action contact.
Model 3124, 3125 and 3126 pressure switches are parti-cularly used when economic efficiency and reliability arethe basic demands on an application.
The pressure switches can be obtained in ranges from0 . . . 10 bar up to 0 . . . 400 bar.The switching point can beset between 0 and 10% of the measuring range for NCcontacts and between 90 and 100% of the measuringrange for NO contacts.
The switching point is factory adjusted.
Features analogue indication
accuracy class 2.5
high switching reliability and service life
gold plated, self-cleaning contact
magnetic snap action contact
NC: 0 . . . 10% of full scaleNO: 90 . . . 100% of full scale
stainless steel case
factory adjusted switching point
Pressure rangesgauge pressurepositive 0 . . . 10 bar to 0 . . . 400 bar
ApplicationsMontoring of gas bottels in:
medical engineering,laboratories,welding,fluid gas heating
DE 7 42 b
P. 1 / 2
Model: 3124, 3125, 3126
tecsis GmbHAn der Sandelmühle 13D-60439 Frankfurt / Main Sales Inland Export Sales [email protected]. +49 (0) 69 / 58 06-0 F. +49 (0) 69 / 58 06-1 70 F. +49 (0) 69 / 58 06-1 77 I. www.tecsis.de
Modifications reserved
31263124 3125Technical data
DE 7 42 b
P. 2 /2
ModelNominal diameterIndication according to ENPressure TypeApplication
- constant load- alternating load- short time load
Pressure connection- position- thread- spanner width
Measuring element- material
Case- movement- pointer
- windowSwitching elementAdjustment
- switching point 1)Switching hysteresisAccuracySwitching data
- switching voltage- switching current- contact rating
Temperature influenceTemperature ranges
- media- ambient
Electrical connectionWeight
40 50 630 . . . 10 bar to 0 . . . 400 barpositive gauge pressure
3/4 x full scale 2/3 x full scalefull scalecopper alloy; with restrictorradial, bottom (according to EN 837-1)
G 1/8 B G 1/4 B G 1/4 BSW 12 SW 14 SW 14
bourdon tubecopper alloystainless steel, polished, with pressure relief opening in back wall copper alloyplastic, white, with stop pin, scale and lettering black,red colour field in switching areapolycarbonat vaulted, snapped into the casecontact pin and contact, gold platedfactory adjustedNC 0 . . . 10% of F. S. or NO 90 . . . 100% of F. S.magnetic snap actionclass 2.5
1.5 to 24 VDC / VAC5 . . . 100 mA≤ 3 W± 0.4% / 10 K
max. +60 °C-40 . . . 60 °Ccable outlet radial (at 8 o’clock) with 1.5 m cable
approx. 0.07 kg approx. 0.11 kg approx. 0.15 kg
Options
other ranges on request
back1/4 NPT
Dimensions (mm)
ND
405063
Dimensions [mm]a8
9.510
b23
27.530
D40.54962
GG 1/8 BG 1/4 BG 1/4 B
h ± 13645
53.5
SW121414
Electrical connnection
1) For increasing pressure. of F. S. = of full scale value
Order details1. Model / 2. Pressure range / 3. Switching pressure / 4. Options
white
brown
Technologies for Sensors Indicators and Systems | Druck | Temperatur | Kraft
DE744a Model : 1929.300.XXXPage 1 /4 tecsis GmbH
Carl-Legien-Str. 40 Vertrieb Inland Export Sales [email protected] Offenbach/Main T. +49 (0) 69 / 5806-0 F. +49 (0) 69 / 5806-170 F. +49 (0) 69 / 5806-177 I. www.tecsis.de
Indicator with Microprocessor5-digit LED-display
with two-coloured displayand two limit contacts
Description
Indicators are electronic devices designed fordigital display of sensor signals. They also supplythe sensor with the power required and, with aid ofadditional facilities such as limit contacts andanaolg output, provide information on the status ofthe process being monitored.
The indicators can be set to the desired measuringrange on site by program-control. If necessary anon-linear scaling with up to 10 scalingrespectively indicating point is provided. If requiredan offset is adjustable. Both the input signal andthe analogue output (option) are freely selectable.
The programming is carried out with the functionkeys on the front of the device. To analyse varyingmeasuring signals a peak value memory(MIN/MAX) and a filter function are available.
For data transmission to a PC a digital interfacecan be obtained. As an alternative a digital input tocontrol the unit can be provided.
The indicator posesses a two-coloured display.The desired colour for operation or alarm can beselected.
Features
O freely programmable by microprocessor
O scale setting on site, without externalcalibration equipment
O integrated sensor supply
O display colour freely selectablefor operation and alarm mode
O freely selectable input signal
O two limit contacts:freely progammable contact function
O filter function
O peak value memory (MIN and MAX)
O option: analogue output freely selectable
O option: digital interface RS485
O option: digital input
Applications
chemical and petrochemical industry,pharmaceutical industry,food and beverage,machine tools and injection moulding,presses,developement and testing.
DE744aPage 2 / 4 tecsis GmbH
Carl-Legien-Str. 40 Vertrieb Inland Export Sales [email protected] Offenbach/Main T. +49 (0) 69 / 5806-0 F. +49 (0) 69 / 5806-170 F. +49 (0) 69 / 5806-177 I. www.tecsis.de
Technical data
Model 1926.300 1929.300Display 2-coloured 7-segment-LED-display− colours red and green: basic colour and alarm colour prgrammable− height 18.5 mm− range -19999...99999 (5 digits)− accuracy 0.03% of F.S. ± 1 digit 0.01% of F.S. ± 1 digit− conversion rate 10/sec.Measuring range free scaling by using up to 10 scaling pointsInput 0...100 mV selectable: 4...20 mA 0...10 VDC
0...20 mA 0...5 VDC± 10 VDC
− channels 1− input resistance for current input: 10 Ω
for voltage input: 950 kΩ− temperatureinfluence
≤ 0.25% of F.S./10K
Sensor supply selectable: 5 VDC / 10 VDC;max.
125 mA
24 VDC; max. 30 mA
Display functions− memory− filter function− process offset
peak value memory (MAX and MIN)programmable up to 100sfreely programmable -19999...99999
2 limit switches 2 transistor outputs: 30 VDC / 100 mA; n-switching1 relais (changeover contact): 240 VAC / 3A or 110 VAC / 5 Atransistor output 1 and relais output 1 are combined
− function limit switch as Hi or Low programmable− switching point program controlled adjustable over the whole display range− hysteresis 1 display digit− response time transistor output: < 75µs
relais output : ca. 8 msMains supply 90...264 VAC 50/60 Hz (galvanically separated of all in- and outputs)− powerconsumption
< 4 Watt
electrical connection screw terminals on the casetemperature ranges− operation− storage− relaitve humidity
0...55 °C-20...60 °C0...90%, non condensating
Protection type front panel IP66Case dimensions see drawings− material GE Lexan 940− mounting panel mounting with clamping frameWeight approx. 0.25 kg
OptionsModel 1926.300 1929.300Mains supply 20...50 VAC respectively 22...55 VDCRelais output 2 1 relais changeover contact: 240 VAC / 3A or 110 VAC / 5 A
transistor output 2 and relais output 2 are combinedAnalogue ouput selectable: 4...20 mA,
0...20 mA0...10 VDC0...5 VDC
− resolution 8 Bit in 250 ms− accuracy ± 0.25% of. F.S., (linear deviation: ± 0.5% of F.S.)− load resistor for current output: max. 500 Ω
for voltage output: min. 500 Ωinterface
1)− RS 485− digital input
9600...1200 baud, 1 start bit, 7 data bits, 1 stop bit, even parityn-switching - High ≥ 3 V, Low ≤ 2 V; TTL-capable; response time 25 ms
of. F.S. = of full scale1) Option: interface only one at a time.
DE744aPage 3 / 4 tecsis GmbH
Carl-Legien-Str. 40 Vertrieb Inland Export Sales [email protected] Offenbach/Main T. +49 (0) 69 / 5806-0 F. +49 (0) 69 / 5806-170 F. +49 (0) 69 / 5806-177 I. www.tecsis.de
Operating and connection elements
Front view
PROG RESET
A LED-displayB function key downward countingC function key scrollD function key programming modeE function key resetF secondary displayG status indication output 1 and 2
Back view
19
10
11
12
13
2356 478
20191716 181514 21
22
23
24
A input signalB sensor supplyC transistor outputD analogue outputE mains supplyF interfaceG relais output 1H relais output 2
Dimensions (mm)
PROG RESET
sectional view of switchboard: 45+0.3 mm x 92+0.3 mm, panel max. 12mm
DE744aPage 4 / 4 tecsis GmbH
Carl-Legien-Str. 40 Vertrieb Inland Export Sales [email protected] Offenbach/Main T. +49 (0) 69 / 5806-0 F. +49 (0) 69 / 5806-170 F. +49 (0) 69 / 5806-177 I. www.tecsis.de
Configuration of connection terminalsConnection terminal
1926.300 1929.3001 input -2 input + input + V3 sensor supply - input + mV, mA4 sensor supply + free5 sensor supply -6 sensor supply +7 transistor output 18 transistor output 0V9 transistor output 210 analogue output -12 analogue output +13 mains supply +14 mains supply -16 digital input B17 digital input A18 digital input 0 V (only for RS 485)
Relais output 1 Relais output 2
19
2120
22
2423
Connection examplesSignal inputTwo-wire 4...20 mA Three-wire 0...20 mA
-Signal
+Signal
Sensor
S- / 0V
S+ / UB+
Indicator
56
31
Sensor
S- / 0VSignalGNDSupplyUB+
S+
Indicator
56
31
Three-wire 0...10V Four-wire 0...10VSensor
S- / 0VSignalGNDSupplyUB+
S+
Indicator
56
21
Sensor
UB-
Meßsignal -
Versorgung -Versorgung +UB+
S-
Informator
56
21
Meßsignal +S+
Four-wire 0...100mV Six-wire 0...100mVSensor
UB-
Signal -
Supply -Supply +UB+
S-
Indicator
56
21
Signal +S+
Sensor
UB-UB+
S-
Indicator
34
21
S+Signal -
Supply -Supply +
Signal +Monitoring -Monitoring +
56
Sen. -Sen. +
Analogue outputexternal evaluation
10
Indicator
12 Signal +Signal -
Order details1. Model2. Options
DE 745 b Model: 3150, 3151page 1/2
Mechanical Pressure Switches „Miniature“1 NC or NO contact
Description
Mechanical pressure switches are the perfectchoise if an electrical signal is required at a givenpressure value.
The measuring principle of the mechanicalpressure switch is a spring loaded diaphragmrespectively for higher pressure ranges a springloaded piston. Under pressure the measuringelement operates an electrical contact.
The switching reliability and long service life isguaranteed by a silver plated contact.
Model 3150 and 3151 mechanical pressureswitches are particularly suitable for all pressuremonitoring and controlling applications thatrequire small dimensions.
The pressure switches can be obtained with anadjustment ranges of 1...70 bar. The switchingoutput can be set over the whole adjustable rangeas a NO respectively NC contact.
The switching point can be adjusted via a centralturning screw on site.
Features
O adjustable on site
O diaphragm or piston pressure switch
O small dimensions
O silver plated contact
O high mechanical service life
Adjustable range
Gauge pressurepositive 1...10 bar
5...70 bar
Applications
Controlling and monitoring of pressure media in:Machines,Plants,Household devices.
DE 745 bpage 2/2
Technical dataModel 3150 3151 OptionsAdjustable range 1...10 bar
5...70 barPressure type positive gauge pressureApplication− max. operating pressure 1-fach− burst pressure:
1...10 bar10...70 bar
20 bar120 bar
Pressure connection G 1/8 Bdiaphragm, 5..70 bar pistonNBR Viton, CR, EPDM
Measuring element− material:diaphragm
piston PUR NBR, VitonCase brass stainless steel,
zinc plated steelSwitchingelement silver plated contact gold plated contactSwitching function 1) NC NOAdjustment on site via central turning screw, under pressureSwitching hysteresis− 1...10 bar− 10...70 bar
<10 % typ.10...15% typ.
Switching data− switching voltage max. 42 V− switching current max. 2 A− contact rating 100 VATemperature ranges− operation -25 ... 85 °CElectrical connection push-on terminals 2 x 6.3 x 0.8 screw connection M2 2)Protection type IP 00Weight ca. 0.03 kg1) At increasing pressure.2) Only for model 3151. Note: Dimensions are changing.
Dimensions (mm)
Order details1. Model2. Adjustable range3. Options
1...10 bar 5...70 bar
DE 746 b Model: 3152, 3153, 3154, 3155page 1/3
Mechanical Pressure Switches1 NC, NO or changeover contact
for positive and negative gauge pressure
Despcription
Mechanical pressure switches are the perfectchoice if an electrical signal is required at agiven pressure value.
The measuring principle of the mechanicalpressure switch is a spring loaded diaphragmrespectively for higher pressure ranges a springloaded piston. Under pressure the measuringelement operates a microswitch.
The switching reliability and long service life areguaranteed by a silver plated contact.
Mechanical pressure switches model 3152, 3153,3154 and 3155 are particularly suitable forpressure controlling and monitoring applications.
The pressure switches can be obtained foradjustable ranges between -800 mbar and 200bar. The switching output can be set over thewhole adjustable range. The switching function isrealized by either NC or NO contacts or bychangeover contacts.
The switching point can be adjusted via a centralturning srew on site.
Features
O adjustable on site
O diaphragm or piston pressure switches
O small dimensions
O silver plated contacts
O high mechanical service life
Adjustable ranges
Gauge pressurenegative -800...-20 mbarpositive 0.3...2 bar
1...10 bar10...70 bar50...200 bar
Applications
Controlling and monitoring of pressure media in:Machine and plant construction.
DE 746 bpage 2/3
Technical DataModel 3152 3153 3154 3155 OptionAdjustable range 0.3...2 bar
1...10 bar10...70 bar50...200 bar
-800...-20mbar
Pressure type positive gauge pressure negativegauge
pressureApplication− max. operation pressure 1-fold− burst pressure -800...-20 mbar 2 bar
0.3...2 bar 10 bar1...10 bar 20 bar10...70 bar 120 bar50...200 bar 300 bar
Pressure connection G 1⁄4 G 1⁄4 G 1⁄4 G 1/8 G 1/8; M12x1.5M10x1 kegelig 1)
Measuring element diaphragm, from 10...70 bar piston− material: diaphragm NBR Viton, CR, EPDM
piston PUR NBR, VitonCase zinc plated steel brass brass, stainless steel,
zinc plated steelSwitching element microswitch: silver plated contact gold plated contactSwitching function 1) NC NO changeover contactAdjustment on site via central turning screw, under pressureSwitching hysteresis 15...20% typ. 15...25 % typ.Switching data− switching voltage max. 42 V− switching current max. 2 A− contact rating 100 VATemperature ranges− operation -25 ... 85 °CElectrical connection− push on terminals 2 x 6.3 x 0.8 3 x 6.3 x 0.8Protection type IP 65; Electrical connection IP 00Weight approx. 0.1 kg approx.0.12 kg
1) At increasing pressure.
DE 746 bpage 3/3
Dimensions (mm)
Models3152 / 3153 /3154 3155
0.3...2 bar1 ...10 bar
10... 70 bar50...200 bar
-800...-20 mbar
Electrical connection
Switching functionNC NO Changeover contact
1
2
4
p
1
2
4
p
1
2
4
p
Connecting terminalsNC NO Changeover contact
1
2
1
4
1
2
4
Order details1. Model2. Adjustable range3. Options
DE 747a Model: 3160, 3161page 1/2
Mechanical Pressure Switcheswith rotatable case
1 changeover contact
for positive and negative gauge pressure
Description
Mechanical pressure switches are the perfectchoise if an electrical signal is required at a givenpressure value.
The measuring principle of the mechanical pressureswitch is a spring loaded diaphragm respectively forhigher pressure ranges a spring loaded piston.Under pressure the measuring element operates amicroswitch.
The switching reliability and long service life areguaranteed by a silver plated contact.
Model 3160 and 3161 mechanical pressureswitches are suitable for all pressure controlling andmonitoring applications.
The pressure switches can be obtained foradjustable ranges between -800 mbar and 200 bar.The switching output can be set over the wholeadjustable range . The switching function is realizedby a changeover contact.
The switching point can be adjusted via a centralturning screw on site.
Features
O adjustable on site
O diaphragm or piston pressure switches
O small dimensions
O silver plated contacts
O high mechanical service life
Adjustable ranges
Gauge pressurenegative -800...-20 mbarpositive 0.3...2 bar
1...10 bar 10...70 bar
50...200 bar
Applications
Controlling and monitoring of pressure media in:Machines and plants,Processes.
DE 747a Page 2/2
Technical dataModel 3160 3161 OptionAdjustable ranges 0.3...2 bar
1...10 bar10...70 bar
50...200 bar
-800...-20 mbar
Pressure type positive gauge pressure negative gauge pressureApplication− max. operating pressure 1-fold− burst pressure ≤ 10 bar 2-fold; > 10 bar 1.5-foldPressure connection G 1⁄4 B G 1⁄4 B G 1/8 B; M12x1.5;
M10x1 conical 1)Measuring element diaphragm, from 50...200 bar piston− material: diaphragm NBR Viton, CR, EPDM
piston PUR NBR, VitonCase zinc plated steel Al / Ms brass, stainless steel
1)Switching element microswitch - silver plated contact gold plated contactSwitching function changeover contactAdjustment on site via central turning screw; under pressureSwitching hysteresis 15...25 % typ.Switching data− switching voltage− switching current− contact rating
max. 250 Vmax. 5 A600 VA / 75 Watt
Temperature ranges− operation -25 ... 85 °CElectrical connection plug according to DIN 43650 with junction boxProtection type IP 65Gewicht approx. 0.23 kg approx. 0.12 kg1) Only model 3160.
Dimensions (mm)
Order details1. Model2. Adjustable range3. Options
Model B a b H G3160 67 10 0 51 G 1⁄43161 69 9 7 58 G 1⁄4
Electrical connection
1
2
3
p
DE 748a Model: 3165, 3166page 1/3
Mechanical Pressure Switchesmanifold style
1 changeover contact
Description
Mechanical pressure switches are the perfect choiseif an electrical signal is required at a given pressurevalue.
The measuring principle of the mechanical pressureswitch is a spring loaded diaphragm respectively forhigher pressure ranges a spring loaded piston.Under pressure the measuring element operates amicroswitch.
The switching reliability and long service life areguaranteed by a silver plated contact.
Model 3165 and 3166 mechanical pressure switchesare particularly suitable for pressure controlling andmonitoring applications in hydraulic or pneumaticdevices.
The pressure switches can be obtained foradjustable ranges between 0.3 bar and 400 bar. Theswitching output can be set over the wholeadjustable range. The switching function is relaizedby a changover contact.
The switching point can be adjusted by a centralturning screw on site.
Merkmale
O adjustable on site
O diaphragm or piston pressure switches
O compact design
O silver plated contacts
O high mechanical service life
O high contact rating
Adjustable ranges
Gauge pressurepositive 0.3...2 bar
0.3...6 bar1...10 bar1...16 bar
10...70 bar 50...200 bar 50...400 bar
Applications
Controlling and monitoring of pressure media in:Pneumatic and hydraulic plants.
DE 748apage 2/3
Technical dataModel 3165 3166 OptionAdjustable ranges 0.3...6 bar
1...16 bar0.3...2 bar1...10 bar
10...70 bar50...200 bar50...400 bar
Pressure type positive gauge pressureApplication− max. operating pressure 1-fold 1-fold− burst pressure 0.3...6 bar 10 bar
1...16 bar 25 bar0.3...2 bar 5 bar1...10bar 20 bar10...70 bar 120 bar50...200 bar 300 bar50...400 bar 600 bar
Pressure connection G 1⁄4 female or flange mounted 1)Measuring element diaphragm, from 10...70 bar piston− material: diaphragm NBR Viton, CR, EPDM
piston PUR NBR, VitonCase Al, anodized black zinc plated steel brass, stainless steel 2)Switching element microswitch - silver plated contact gold plated contactSwitching function changeover contactAdjustment on site via central turning screw, under pressureSwitching hysteresis 15...25 % typ.Switching data− switching voltage− switching current− contact rating
max. 250 Vmax 5 A600 VA / 75 Watt
Temperature ranges− operation -25 ... 85 °CElectrical connection plug according to DIN 43 650 with junction boxProtection type IP 65Weight approx. 0.18 kg approx. 0.37 kg1) Please specify in your order2) Only model 3166.
DE 748aSeite 3/3
Dimensions (mm)Model3165
3166
Electrical connection
12
3
p
Order details1. Model2. Adjustable range3. Connection type4. Options
DD 750 a Model: 3950, 3951, 3952, 3953Page 1/4
Intelligent Pressure Transmitter ‘Digitrans’with internal or front flush diaphragmfor gauge pressure and absolute pressure
accuracy 0.15%
standard output: 4...20 mA; 2-wire system
Description
The intelligent pressure transmitter ‘Digitrans’allows by its freely programmable range anoptimised adaption to the measuring task.
The good readable and high contrast displayoffers room for extra information besides thedigital value , bargraph and tendency display. Thestandard display is mounted for frontview, but itcan be easily adjusted for top view.
The menues are self-explanatory and allow tochoose the configuration parameter as userlanguage, engineering unit, zero and span,inverted output signal etc. The language can beswitched between German, English, Spanish andItalian. The hidden buttons prevent an adjustmentby mistake.
The intelligent pressure transmitter ‘Digitrans’offers the possibility for a non lineare scale (tanklinearisation). Up to 32 points of the curve can beprogrammed.
All wetted parts are made of stainless steel andtotally welded (no internal sealings).
The housing made of resistant plastic material,reinforced by fiberglass has protection classIP 65.
Features
O Measuring ranges from 400 mbar to4000 bar
O Maximum Turn down: 1:20
O Good readable and high contrast display
O Corrosion resistant stainless steel designO Completely welded pressure cellO Display adjustable for front or top viewO Simple programming on siteO Protection type IP 65 (option IP 67)
Measuring ranges
Gauge pressure 0...0.4 bar to 0...4000 barAbsolute pressure 0...0.4 bar to 0...16 bar
Application
Process engineering,Plant and apparatus design,Hydraulic and pneumaticDevelopment and laboratory applications.
DE 750 aPage 2/4
Technical data
Model 3950 / 3952 OptionMeasuring ranges [bar]1) 0,4 1,6 6 16 40 100 250 600 1000 1600 2500 4000
Overload limit [bar] 2 10 35 80 80 200 500 1200 1500 2000 3000 4400
Pressure type positive gauge pressure Abs. press. (up to 16bar), negative andpositive gauge pressure
Output signal 4...20 mA - 2-wire systemSensor element piezoresistive thin filmAccuracy 2) 0.1 % of F.S. ( ≤ 0.3% for measuring range > 1000 bar)− Turn down ≤ 1:5 no change in accuracy− Turn down > 1:5 accuracy ⋅ (Turn down / 5)Hysteresis ≤ ± 0.04 % of F.S.Repeatability ≤ ± 0.05 % of F.S.Stability per year ≤ ± 0.1 % of F.S. in rated conditionsCase resistant plastic material reinforced by fiberglass (PBT)Pressure connection− 3950 G 1⁄2 B according to DIN 837 (M16 x 1,5 female from 1600 bar) 1⁄2 NPT− 3952 G 1 B, from 0...6 bar to 0...600 bar G 1⁄2 B front flush diapragm
wiht O-ringG 1 1⁄2 acc. to ISO228
front flush diaphragm with O-ring (0...0.4 to 0...16 bar)Wetted parts− 3950 stainless steel 1.4571 and 2.4711 (1.4534 for measuring range
>1000 bar)− 3952 stainless steel 1.4571
O-Ring: NBRHastelloy C4Viton, EPDM
Electrical connection cable gland M20x1.5 with internal screw terminals (for cable diameterfrom 7 to 13 mm, wire gauge to 2.5 mm²)
Power supply 12...36 VDCLoad RA[Ω ] ≤ (UB[V] - 12 V) / 0.023 ATemp. compens. range -20...80°CTemperature influence ≤ 0.1 % /10 K (for zero point and measuring range)Total accuracy (10...40°C) ≤ 0.15% (≤ 0.6% for measuring range > 1000 bar)Adjustability− Zero point -2.5...99%− Measuring range Turn down 1:20 ( 1:2 for measuring range > 1000bar)Response time ≤ 10 ms (within 10 % to 90 % of F.S.)Protection type IP 65 according to EN 60529/IEC 529 IP 67 on requestEmission 3) according to EN 61326Interference 3) according to EN 61326Electric protection type reverse polarity overload and short circuit protectionShockVibration
100g according to IEC 770 (mechanical shock)5g according to IEC 770 (vibration at resonance)
Temperature ranges− storage− medium− ambient
-40 ... 85 °C (-35 ... 80°C with display)-30 ... 105 °C 4)-20 ... 85 °C (-20 ... 70°C with display)
Weight approx. 0.2 kgof F.S. = of full scale value
1) Other measuring ranges can be adjusted by turn down.2) Terminal point adjustment according to DIN 16086, incl. Linearity, repeatability and hysteresis. Calibrated for
vertical mounting, pressure connection downwards.3) Declaration of conformity on request4) For pressure connection G 1 1⁄2 up to 30 min. 140°C at ambient temperatures < 50°C.
DE 750 aPage 3/4
Dimensions (mm)
Case
Pressure connections
internal diaphragm front flush diaphragm with O-ring
G 1⁄2 B M 16 x 1,5 G 1⁄2 B G 1 B
G1/2
6
17,5
3
320
9.5
20
A-001
27
31.8
+ -1
20.3
12
4.8M16x1.5
60°26.5
A-026
36,5
32
20,5
10
18 -0,1
G1/2B
18,5 x 23,9 x 1,5
15 x 2
27
A-015
33
20,5
10
30 -0,1
41
29,7 x 35,7 x 2
26 x 2
G1B
A-011
Screw-in aperture or weld-on socket
G 1⁄2 M 16 x 1,5 G 1⁄2 G 1
24,5
+1
19-0
,5
Min
. 14.
5
7
G1/2(DIN 16288)
A0.1
A
S-001
M16X1.560°
4.8
S-008
50
21.3-0,2
G1/2
19.4+0.1
21
18.2+0.1
15-0
.2
Min
.10.
5
0.1 A
A
S-003
50
33.5 -0.2
G130.5 +0.1
30.1 +0.1
2115-0
.2
Min
.10.
5
0.1 A
A
S-004
DE 750 aPage 4/4
Electrical connection
Two-wire system
Terminal assignmentUB / S+
0V / S-
Test + Test -
+
E-046
Readout sample
Order details1. Model2. Measuring range3. with / without display4. Options
E01 mbarTEMP 27°CP-MAX 390
Tendency display
error code
Display ofadditional information(temperature, max-, min-or nominal-value.)
Bargraph display
Measuring value display
line 1 (eng. unit)line 2
line 3
Technologies for Sensors Indicators and Systems | Druck | Temperatur | Kraft
Models: 3960tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 752
p. 1/4
Digital Pressure GaugeAccuracy 0,5 %
4 digit LCD display
Description
Digital pressure gauges provide a digital localindication independent from mains supply.
Their accuracy, reliability and resistance tomechanical load make them suitable for pressuremeasuring tasks in various applications.
To ensure an easy readout in any installationposition the front cover may be rotated up to350°.
Additionally the display case may be rotatedaxial-wise by untightening the counter nut at thepressure connection.
The measuring ranges, graded in accordancewith EN range from 1 bar up to 400 bar.
The programming of the parameters is done bymeans of the front keys.
The integrated battery guarantees an operationindependent from mains supply.
Optionally a peak value memory, an analogeoutput or a limit contact can be provided.
The digital pressure gauge meets the electronicmagnetic compatibility (EMC) requirements toEN 61326
Features
O Ranges from 1 bar up to 400 bar
O Finely graded selection of pressure rangesaccording to EN
O LCD displayO High overload protectionO Option: peak value memoryO Option: analogue outputO Option: limit contacts
Measuring ranges
Gauge pressurenegative -1...0 barpositive 0...1 bar to 0...400 bar
Applications
Mechanical engineering,Plant and gadgets construction,Hydraulics and pneumatics.
DE 752
p. 2/4
Technical dataModel 3960 OptionDisplay− range− accuracy− convertion rate 2)
7-segment LDC-display, 12,7 mm high99990.5 % of F.S. 1)5 /sec
Ranges to EN 0...1 bar to 0...400 bar 1000, 1600 and2000 bar on request
Pressure type positive gauge pressure negative gaugepressure
Overload limit ≤ 40 bar 3-fold≥ 60 bar 2-fold≥ 250 bar 1,5-fold
Wetted parts stainless steel 1.4571; Al2O3; NBRPressure connection G 1⁄4 A other on requestProgrammable parameter− zero point adjustment ≤ ± 25% of F.S.Power supply− battery life
− autom. switch off 3)
9 V monoblock battery5000h (600 mAh)10000h (1200 mAh)2..90 min. (factory set)
Temperature comp. range 0.... 60°CTemperature influence− zero point− span
≤ ± 0.2 % /10 K≤ ± 0.1 % /10 K
Protection type− max. rel. humidity
IP 65 accord. EN 60529/IEC 529< 90%, non condensating
Emission 4) to EN 61326
Interference 4) to EN 61326Electrical protection types reverse polarity protectionTemperature ranges− storage− media− ambient
-30 .... 80 °C-30 .... 85 °C0 .... 60 °C
Case plasticWeight approx. 0.4 kg
of F.S. = of full scale value1) Terminal point adjustment according to DIN 16086 incl. linearity and hysteresis.2) Factory set between 1 to 10 /sec.3) Not available for options analog output or limit contact4) Declaration for conformity on request
Options 5)
Peak value memory− programmable as MIN- or MAX-value memoryAnaloge output− load− electr. connection
0 ... 2 VDC≥ 100 kΩround connector M12x1, 5-pin or cable outlet, 0.5 m cable
Limit contact− switching function− contact rating− adjustability− electr. connection
Relay outputNO30 VAC/DC, 2Aswitching point and rest point freely programmableround connector M12x1, 5-pin or cable outlet, 0.5 m cable
5) Options analoge output and limit contact not available together.
DE 752page 3/4
Dimensions (mm)
Case
G1/4 A
Sw24
2
38
2489
30
511474
M12
x1
rotatabledisplay
Screw-in aperture
G 1⁄4
10
13 –0
,5
18
∅ 5,5 +0,2
DE 752
p. 4/4
Electrical Connection
Analoge output
5-pin connector cable outlet
O V
+S
+S 4
O V 3
Limit contacts
5-pin connector cable outlet
2
5
Order details1. Model2. Measuring range3. Options
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models: 3325, 3326tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
DE 755d
p. 1/4
Pressure Sensors “ Miniature“with internal and front flush diaphragm
accuracy 0.5 %
standard output: 4...20 mA; 2-wire-system or 0.1...10 VDC; 3-wire system or 1...5 VDC; 3-wire system
Description
Pressure sensors „Miniature“ are top of the rangepressure transducers.
Due to its miniaturized construction they are theperfect choise for extrem space-savinginstallation. Reliability, resistance to corrosionand mechanical load make them suitable for allpressure measuring tasks.
The measuring ranges, graded in accordancewith EN, range from 16 bar to the maximumpressure range of 1000 bar. The case and wettedparts comprise stainless steel and are thusresistant to chemically aggressive media. Thepressure connection and measuring element arewelded together, making the measuring systemparticularly resistant to mechanical shock orvibration.
Round connectors M12x1, DIN 43650 C plugs orcable outlets are used to pick up the electricaloutput signals.
The pressure sensors „Miniature“ meet theelectronic magnetic compatibility (EMC)requirements to EN 61326.
Features
O miniaturized construction
O pressure connection G 1⁄4 B to DIN 3852 E orG1/4 B front flush
O high peak pressure resistance
O high alternating load resistance
O high long-term stability
O corrosion rsistant stainless steel designO resistant to mechanical load
O for dynamic and static measurements
Measuring ranges
Gauge pressurepositive 0...16 bar to 0...1000 bar with internal diaphragmPositive 0...25 bar bis 0...1000 bar with front flush diaphragm
Applikations
Hydraulics and pneumatics,General mechanical engineering,Medical engineering.
DE 755d
p. 2/4
Technical data
Model 3325 3326 OptionPressure type positive gauge pressure positive gauge
pressureOutput signal 4...20 mA - 2- wire system
1...5 V - 3- wire system0.1...10 VDC - 3- wire system
Accuracy 0.5 % of F.S. 1)Ranges to EN 0...16 bar to 0...1000 bar 0...25 bar to 0...600 bar other on requestSensor element thin filmRepeatability ≤ ± 0.05 % of F.S.Stability per year ≤ ± 0.2 % of F.S. in rated conditionsCase stainless steel 1.4571Pressure connection G 1⁄4 A to DIN 3852 form
E with Viton sealingG 1⁄4 B to EN 837
G 1⁄4 B front flushdiaphragmwiht O-ring
other on request
Wetted parts stainless steel 1.4571and 1.4542
stainless steel 1.4571,NBR
Overload limit ≤ 600 bar 2- x= 1000 bar 1.5- xvacuum resistant
Electrical connection round connector M12x1 (4-pin)cable outlet with 1.5 m cableplug DIN 43650 C with junction box
Power supply− 4...20 mA− 1...5 V− 0.1 ... 10 V
10 ... 30 VDC 8 ... 30 VDC14 ... 30 VDC
Power consumption current output: signal currentvoltage output: 8 mA
Load− 4...20 mA− 1...5 V− 0.1 ... 10 V
RA [Ω ] ≤ (UB [V] - 10 V) / 0.02 A> 10 kΩ> 20 kΩ
Temperature comp. range -20 ... 85°CTemperature influence ± 0.2 % /10 K, on zero and spanResponse time ≤ 2 ms (within 10 % to 90 % of F.S.)Protection type IP65 to EN 60 529/IEC 529 IP67 on requestEmission 2) to EN 61326Interference 2) to EN 61326Electrical protection types polarity, overload and short-circuit protectionTemperature ranges− storage− media− ambient 3)
-40 .... 100 °C-40 .... 100 °C-40 .... 100 °C
Weight ca. 0.05 kgof F.S. = of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis2) Declaration of conformity on request3) Version for oxygen from 25 bar, max. 60°C
DE 755d
p. 3/4
Dimensions (mm)
Caseround connector M12x1 plug DIN 43650 C cable outlet
1243
.5
1943
.519
19
43.5 49
Pressure connection - front flusch diaphragm
G 1⁄4 A DIN 3852 -E G 1⁄4 B EN 837 G 1⁄4 B
12
G1/4 A
21
Flachdictung
19
A-021
22
13
5
9,5
G1/4A-019
1930
.9
26
20
8
G1/4B
O-Ring 8x1.5
A-027
19
Screw-in aperture to
G 1⁄4 DIN 3852-E G 1⁄4 G 1⁄419+0.4
13.2+0.2
90°
0.1
G1/4
1.5
1419
G1/4
5,5
16,5
+1
13-0
,5
Min
.9,5
A0.1
A 11 0.1
G1/4
35
20.5
+
DE 755d
p. 4/4
Electrical connection
Two-wire system
round connector M12x1 plug DIN 43650 C cable outletUB / S+
0V / S-
1 2
4 3
E-033
UB / S+
0V / S-
1
3 2
E-005
UB / S+
0V / S-
brown
blue
E-016
Three-wire system
round connector M12x1 plug DIN 43650 C cable outletUB
0V / S-
S+
41
32
E-034
UB
0V / S-
S+
E-006
0V / S-
UB
S+
brown
green
black
E-018
Connection table for DIN plug or cable outlet
4...20 mA(2 - wire)
0...10VDC(3 – wire)
plugM12x1
DINplug
cableoutlet
plugM12x1
DINplug
cableoutlet
Supply: UB+ 1 1 brown 1 1 brownSupply: 0V 3 2 green 3 2 greenSignal: S+ - - 4 3 whiteSignal: S- - - 3 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
AE 722a Model: 3374page 1/4
Pressure Sensorsfor Mobile Hydraulics
with internal diaphragmfor gauge pressure
Accuracy 1%
Standard output: 4...20 mA; 2-wire systemor 1...5 VDC; 3-wire system
Description:
The pressure sensors model 3374 are especiallydesigned for the needs in the field of mobilehydraulics. The sensor element is placed in thepressure connection in order to be protectedagainst damage. In case of a damage of thepressure sensor can not loose oil.
Measuring ranges from 60 bar up to 600 bar,graded in accordance with EN, cover the wholerange of hydraulic applications. The measuringelement guarantees a high long-term stabilityeven in applications with frequent changes inload.
The pressure sensor is designed to withstandshock loads up to 1000g and vibrations up to 50gaccording to DIN IEC 770.
Even extreme thermal shocks have no influenceon the operational safety. Apart from thestandard electrical connections a cable outlet IP69 K is available for applications demandingsteam jet protection.
The pressure sensors meet the electromagneticcompatibility (EMC) to EN 50081-1, EN 50081-2and EN 50082-2.
Features
O Measuring ranges from 60 to 600 bar
O Finely graded selection of ranges to EN
O Corrosion resistant stainless steel designO Extremely resistant to shock and vibrationsO Protection type IP65 up to IP69KO High peak pressure resistance
Measuring ranges
Gauge pressurepositive 0...60 bar to 0...600 bar
Applications
Mobile hydraulics:Farm trucks,Cranes,Caterpillars,Special vehicles.
AE 722apage 2/4
Technical data
Model 3374 OptionsPressure type positive gauge pressureOutput signal 4...20 ma - 2-wire system
1...5 VDC - 3-wire systemother on request
Accuracy 1) 1% of F.S.Ranges accord. to EN 0 ... 60 bar to 0 ... 600 barSensor element thin filmRepeatability < ± 0.1 % of F.S.Stability per year < ± 0.2 % of F.S. in rated conditionsCase stainless steel 1.4571Pressure connection G 1⁄4 A to DIN 3852-E pressure port ∅ 3,5 mm;
M 14x1.5 DIN 3852-E/F pressure port ∅ 3,5 mm;7/16-20 UNF SAE J 514 pressure port ∅ 3,5mm;1⁄4 NPT pressure port ∅ 3,5 mm
CDS-system 2)
Wetted parts Stainless steel1.4571 and 1.4542Overload limit 2-times ; vacuum resistantElectr. connection round connector M12x1 (4-pins)
cable outlet with 1.5 m cableplug to DIN 43650 Cwith junction box
Power supply 10...30 VDCPower consumption− 4...20 mA− 1...5 V
signal currentapprox. 5mA
Load− 4...20 mA− 1...5 V
RA[Ω ] ≤ (UB[V]-10V)/0,02A> 5 kΩ
Temperature comp.range
0.... 85°C
Temperature influence− zero point− span
≤ ± 0.3 % /10 K≤ ± 0.2 % /10 K
Response time < 5 ms (within 10 % to 90 % of F.S.)Protection type(EN 60529/IEC 529)
IP 67 for round connector M12x1IP 69 K (steam jet protection) for cable outlet
IP 65 for DIN 43650 Cplug
Emission 2) to EN 50 081-1 and EN 50 081-2Interference 3) to EN 50 082-2 respectively DIN 40 839Shock 1000g to IEC 770Vibrations 50g to IEC 770Electric. protection types Polarity, overvoltage and short circuit protectionTemperature ranges− Storage− Media− Ambient
-40 ... 85 °C-40 ... 125 °C-30 ... 85 °C
Ambient temp.-40 ... 85 °C
Weight Approx.. 0,2 kgof F.S. = of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. linearity and hysteresis2) Minimised pressure port for dampening of pressure peaks3) Declaration of conformity on request
AE 722apage 3/4
Dimensions (mm)
Case
Round connector M12x1 Plug to DIN 43 650 C Cable output
69 24
87 24
104
24
82Process connection
G 1⁄4 M14x1,5 7/16-20 UNF
27
G1/4ADIN 3852-E
27
DIN 3852-EDIN 3852-F
M14 x 1,57/16-20 UNF
27
9,14
Screw-in-aperture to DIN
G 1⁄4 DIN 3852-E M14x1,5 DIN 3852-E19
13.290°
0.1
G1/4
1.5
1218
,5
2014
90°
0.1
M14x1,5
1.5
1218
,5
AE 722apage 4/4
Electrical connection
Two-wire system
Round connector M12 x 1 Plug to DIN 43 650 C Cable outletUB / S+
0V / S-
1 2
4 3
UB / S+
0V / S-
1
3 2
UB / S+
0V / S-
brown
green
Three-wire system
Round connector M12 x 1 Plug to DIN 43 650 C Cable outletUB
0V / S-
S+
41
32
UB
0V / S-
S+
0V / S-
UB
S+
brown
green
white
Connection table for plug or cable outlet
4...20 mA(2 - wire)
0...10VDC(3 - wire)
PlugM12x1
DINplug
Cableoutlet
PlugM12x1
DINplug
Cableoutlet
Supply: +UB 1 1 brown 1 1 brownSupply: 0V 3 2 green 3 2 greenSignal: +S - - 4 3 whiteSignal: -S - - 3 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
Subject to technical changes
DE 756 b model: 3399 page 1/4
Pressure Sensors for highest pressuresaccuracy 0.5 %
standard output: 4...20 mA; 2-wire-system oder 0...5 VDC; 3-wire-system oder 0...10 VDC; 3-wire-system
Description
Pressure sensors for highest pressures are top ofthe range pressure transducers.
Due to the flexible construction of both the electricaland the mechanical connections the pressure sensormodel 3399 is the perfect choice in the field ofhighest pressure measurement. Reliability, safety,resistance to corrosion and high mechanical loadmake them suitable for all highest pressuremeasuring tasks.
The measuring ranges range from 0...2500 bar tothe maximum pressure range of 0...8000 bar. Thecase and wetted parts comprise stainless steel andare thus resistant to chemically aggressive media.The pressure connection and measuring elementare uptightened via a metall cone. Therefore thereis no risk of leakage in the welding seams.
A relief bore ensures a defined escape for the mediain direction of the pressure connection in case of adamage.
Plugs according to DIN 43650, 4-pin roundconnectors M12x1 or cable outlets are used to pickup the electrical output signals.
The pressure sensors for highest pressures meet theelectronic magnetic compatibility (EMC)requirements to EN 61326.
Features
O high mechanical load rating
O high peak pressure resistance
O high alternating load resistance
O high long-term stability
O corrosion resistant stainless steel designO mechanical safety conception
O for dynamic and static measurements
Measuring ranges
Gauge pressurepositive 0...2500 bar bis 0...8000 bar
Applications
Hydraulic presses,compressors for high and highest pressures,machine tools,test machinery
DE 756 b page 2/4
Technical data
Model 3399 OptionPressure typet positive gauge pressureOutput signal 4...20 mA - 2-wire system
0...5 VDC - 3-wire system0...10 VDC - 3-wire system
0...20 mA 3-wire
Accuracy 0.5 % v.EW. 1)Ranges 0 ... 2500 bar
0 ... 4000 bar0 ... 5000 bar0 ... 6000 bar0 ... 7000 bar0 ... 8000 bar
other ranges onrequest
Sensor element thin filmRepeatability ≤ ± 0.05 % of F.S.Stabilty per year ≤ ± 0.2 % of of F.S. in rated conditionsCase stainless steel 1.4301Pressure connection 9/16-18 UNF F250-C up to max. 6000 bar
1/4-28 UNF LH M 250-C up to max. 4000 bar3/8-24 UNF LH up to max. 8000 barM14x1.5 LH up to max. 5000 barM16x1.5 female up to max. 4000 bar
other on request
Wetted parts stainless steel 1.4542 and 1.4534Overload limit ≤ 5000 bar 1.2-fold; > 5000 bar 1.1-fold;Electr. connection plug according to DIN 43650 with junction box;
round connector M12x1 (4-pin)cable outlet with 1.5mcable
Power supply 14....30 VDC, (10...30 VDC for output 4...20 mA)Power consumption output 4...20 mA: signal current
output 0...20 mA: signal current + 10 mAvoltage output: 25 mA
Load− 4...20 mA− 0...20 mA− 0...5 V− 0...10 V
RA[Ω ] ≤ (UB[V]-10V)/0.02ARA[Ω ] ≤ (UB[V]-14V)/0.02A> 5 kΩ> 10 kΩ
Temperature comp.range
-20 ... 80°C
Temperature influence ± 0.2 %/10 K, on zero and spanResponse time ≤ 10 ms (within 10 % to 90 % of F.S.)Protection type(to EN 60 529/IEC 529)
IP 65 for plug DIN 43650IP 67 for round connector M 12 x 1
IP 67 for cable outlet
Emission 2) accord. EN 61326Interference 2) accord. EN 61326Electr. protection types polarity, overvoltage and short circuit protectionTemperature ranges− storage− media− ambient
-40 .... 85 °C-20 .... 80 °C-20 .... 80 °C
Weight approx. 0.3 kgof F.S. = of full scale value
1) Terminal point adjustment to DIN 16 086, incl. linearity and hysteresis2) Declaration of conformity on request
DE 756 bpage 3/4
Dimensions (mm)
Case plug DIN 43 650 round plug M12x1 cable outlet
ca.48
27,5
73.5
+ -3 40 4073
.5+ -3
13.5
73.5
+ - 403
Pressure connections
9/16-18 UNF M16x1.5 M14x1.5 LH 1⁄4-28 UNF LH
27
11.2
5°9.
65 20.3
31,8
+ 1-
4.3
60°9/16-18 UNF
26.5
27
31.8
+ -1
20.3
12
4.8
M16x1.5
60°
26.5
57+ - 58°
2845
5.5
M14x1.5 LH
1
2217
44+ -1
3214
.3
3.181/4-28 UNF LH
M-250 C
-2°
3/8-24UNF LH
22
52
40
19.1
59° -2°
3
3/8-24UNF LH
-+ 1
DE 756 b page 4/4
Electrical connection
Two-wire-system
plug DIN 43650 round connector M12x1 cable outletUB / S+
0V / S-
13
2
E-001
UB / S+
0V / S-
1 2
4 3
E-033
UB / S+
0V / S-
braun
grün
E-015
Three-wire-system
plug DIN 43650 round connector M12x1 cable outletUB
0V / S-
S+
E-002
UB
0V / S-
S+
41
32
E-034
0V / S-
UB
S+
braun
grün
weiß
E-017
Connection table for DIN plug or cable outlet
4...20 mA(2 - wire)
0...10VDC(3 – wire)
PlugM12x1
DINplug
Cableoutlet
PlugM12x1
DINplug
Cableoutlet
Supply: UB+ 1 1 brown 1 1 brownSupply: OV 3 2 green 3 2 greenSignal: S+ - - 4 3 whiteSignal: S- - - 3 2 green
Order details1. Model2. Measuring range3. Output signal4. Options
Technologies for Sensors Indicators and Systems Druck Temperatur Kraft
model: 3317tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
AE 724a
S. 1/2
Pressure Sensors Specialfor low and differential pressures
Accuracy 1 % respectively 0,6 %
Standard output: 4...20 mA; 2-wire systemor 0...10 VDC; 3-wire system
Description
Pressure sensors special for low and differentialpressures are preferably used for themeasurment of lowest gauge pressures anddifferential pressures.
The main applications are in heating, airconditioning and filter technology as well asmedical technology.
The graded measuring ranges range from 0...2,5mbar to 0...1000 mbar.
The sturdy aluminium case enables a highmechanicla stability and very good EMCcharacteristics.
A piezoresistive Chip serves as the measuringelement. The integrated amplifier provides aprocess suitable output signal (e.g. 4...20 mA or0...10 VDC).
Features
O Measuring ranges from 2,5 mbar to1000 mbar
O Sturdy aluminium caseO High reliabilityO Very good EMC-characteristics
Measuring range
Gaugepressures 0...2,5 mbar to 0...1000 mbar
Application
Heating and air conditioning,Filter technology,Medical technology.
AE 724a
S. 2/2
Technical dataModel 3317Pressure type gauge pressure respectively differential pressureMeesuring ranges [mbar] 2,5 5 10 25 50 100 250 500 1000Overload limit [mbar] 250 250 250 375 500 750 750 1500 3000Output signal 4...20 mA - 2-wire technology
0...10 VDC - 3-wire technologyAccuracy 1% of F.S. 0.6% of F.S.Sensor element piezoresistiveHysteresis 0.1%Repeatability [% of F.S.] 0.3 0.2 0.1Stability per year [% of F.S.] 2 0.5 0.1Pressure connection 2 tube connctions for 4mm tubeMedia only suitable for dry non-aggressive gasesElectr. connction PG7 – screw coupling and internal screw terminalsPower supply 10...30 VDC, (15...24 VDC for output 0...10 V)Load 20 ... 400 Ω for output 4...20 mA
> 2 kOhm for output 0...10 VTemperature comp. range 0.... 50°CTemp. influence [% of F.S.] ± 2.0 ± 1.0 ± 0.7Operating temperature -20 .... 70 °CResponse time 1 msProtection type IP 65 according to EN 60529/IEC 529Case aluminiumWeight approx. 0.16 kg
Dimensions (mm) Electrical connectionPG7- screw coupling fixing pressure connection
4...20 mA / 2-wire systemUB / S+
0V / S-
0...10 V / 3-wire systemUB
0V / S-
S+
Order details1. Model2. Measuring range3. Output signal Subject to technical changes
Technologies for Sensors Indicators and Systems Druck Temperatur Kraft
Model: 3170, 3171, 3172tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
AE 730
page 1/2
Mechanical Pressure Switchesfor differential pressure
1 changeover contact
Description
Mechanical pressure switches for differentialpressure are the perfect choise if an electrical signalis required at a given differential pressure value.
The measuring principle of the mechanical pressureswitch is a spring loaded diaphragm respectively forhigher pressure ranges a spring loaded piston.Under pressure the measuring element operates amicroswitch.
The switching reliability and long service life areguaranteed by a silver plated contact.
Model 3170, 3171 and 3172 mechanical pressureswitches for differential pressure are particularlysuitable for controlling and monitoring applicationsof differential pressure.
The pressure switches can be obtained foradjustable ranges between 0.3 bar and 50 bar. Theswitching output can be set over the wholeadjustable range. The switching function is realizedby a changever contact.
The switching point can be adjusted via a centralturning screw on site.
Features
O adjustable on site
O diaphragm or piston pressure switch
O compact design
O silver plated contacts
O high mechanical service life
O high contact rating
Adjustable ranges
Differential pressure0.3...2 bar0.5...3 bar2...10 bar5...50 bar
Appliacations
Controlling and monitoring of filters,Level measurement,Flow measurement.
AE 730page 2/2
Technical data
Model 3170 3171 3172 OptionAdjustable ranges 0.3...2 bar 0.5...3 bar 2...10 bar
5...50 barPressure type differential pressureApplication− max. operating pressure 10 bar 5-fold− burst pressure 15 bar 200 / 350 barPressure connection 2x G 1/8 femaleMeasuring element diaphragm, from 2...10 bar piston− material: diaphragm NBR Viton, CR, EPDM
piston PUR NBR, VitonCase brass zinc plated steel,
stainless steelSwitching element microswitch - silver plated contacts gold plated contactsSwitching function changeover contactAdjustment on site via a central turning screw, under pressureSwitching hysteresis 15...25 %Switching data− switching voltage− switching current− switching power
max. 250 Vmax. 5 A600 VA / 75 Watt
Temperature ranges− operation -25 ... 85 °CElectrical connection plug according to DIN 43650 with junction boxProtection type IP 65Weight approx. 0.43 kg approx. 1.05 kg approx. 1.13 kg
of.F.S. = of full scale value
Dimensions (mm)
Einstellschraube
Druckanschluß "-"
Druckanschluß "+"
DIN 74 - Km 5
Model: 3170 Model: 3171 und 3172
Elektrical connection1
2
3
pOrder details1. Model2. Adjustable range3. Options Subject to technical changes
Technologies for Sensors Indicators and Systems Pressure Temperature Force
Models: 3309tecsis GmbHCarl-Legien-Str. 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
AE 731
S. 1/2
Pressure SensorsFor Refrigeration conditioning
O Medium wetted parts of stainless steelO No internal sealing elements
O High peak pressure resistance
O High long-term stability
Model 3309Pressure Type Negative and positive gauge pressureOutput Signal 4...20 mA - 2-wire system
0...10 VDC - 3-wire systemAccuracy % of F.S. 1) ± 1 % of F.S. 1)Ranges according to EN -0,8 to 7 bar /- 1 to 9 bar / -1 to 15 bar
-1 to 24 bar /0 to 18 bar / 0 to 30 bar / 0 to 40 bar
Repeatability ≤ ± 0,1 % of F.S.Stability (annual) ≤ ± 0,3 % of F.S. in rated conditionsCase Stainless steel 1.4301Pressure connection 7/16-20 UNF 2 B / SchraderWetted parts Stainless steel 1.4571 and 1.4542Overload limit ≤ 10 bar 3,5 x; ≤ 40 bar 2 fach;Electrival connection Plug to DIN 43 650 with junction boxPower supply 12....30 VDC, (14...30 VDC for output 0...10 V)Power consumption- 4…20 mA- 0…10 V
Signal current8 mA
Load- 4…20 mA- 0...10 V
≤ (UB [V] - 10V) / 0,020A≥ 10 KΩ
Temp. compens. range 0....80°CTemperature influence ± 0,5 % /10 K, zero point and full scaleResponse time ≤ 40 ms (within 10 % to 90 % of F.S.)Protection type IP 65 toEN 60529 / IEC 529Emission 2) to EN 61326Interference 2) to EN 61326Electrical protection types Polarity-, overload- and short-curcuit-protectionTemperature ranges− Storage− Medium− Ambient
-35 .... 80 °C-25 .... 80 °C-25.... 60 °C
Weight approx. 0,15 kgof F.S. = of full scale value
1) Terminal point adjustment according to DIN 16 086, incl. Linearity and hysteresis2) Declaration of conformity on request
Models: 3309tecsis GmbHCarl-Legien-Straße 40D-63073 Offenbach/MainT. ++49 (0) 69 / 5806-0
Vertrieb InlandF. +49 (0) 69 / 5806-170
Export SalesF. +49 (0) 69 / 5806-177
E. [email protected]. www.tecsis.de
AE 731
S. 2/2
Dimensions (mm)CasePlug according to DIN 43 650 pressure connection 7/16-20 UNF 2 B / Schrader
416
48
4235
75
SW19
Electrical connection
Two-wire system Three-wire system
UB / S+
0V / S-
1
3
2
E-003
UB
0V / S-
1
3
2
S+
E-004
Connection table for DIN plug or cable outlet4...20 mA
(2-wire)0...10 VDC
(3-wire)Supply: UB+ 1 1Supply: 0V 2 2Signal: S+ - 3Signal: S- - 2