Mock Logbook
This mock logbook was produced at the request of internal verifiers at City of Westminster College. SCST felt it might be useful to publish it on the website. It has been produced by Chris Burke with grateful thanks to Gretta Borthwick and Jo Nemes for their invaluable input.
Record of Clinical Practice
How to put your RCP togetherI am grateful to Jo Nemes and Gretta Borthwick who
contributed to this document
Record of Clinical Practice
The RCP is presented to SCST in 2 parts: Part I is presented toward the end of year 2 of
the programme Part II is presented toward the end of year 4
of the programme
Internal Verification
This process provides the monitoring of quality of work-based assessment
IVs visit a minimum of twice a year
Any documentary evidence of these visits MUST be included in the logbook
Life Support
A copy of a current life support certificate
This should be a minimum of intermediate life support
If only basic life support is available an assessment of defibrillation technique must be included
ECG
3 ECG assessments are carried out in the workplace. For EACH, the following documentation must be provided:
Sphygmomanometry
4 assessments of blood pressure measurements are completed. At least ONE must be manual
For each assessment the following documentation must be provided:
Exercise Testing
4 assessments of ETT are completed
For each assessment the following documentation must be provided:
Ambulatory ECG (AECG)
4 assessments of AECG are completed. These are a mixture of continuous and events recorders which reflect the work of the department
For each assessment the following documentation must be provided:
Ambulatory BP (ABP)
4 assessments of ABP are completed.
For each assessment the following documentation must be provided
Cardiac Catheterisation
4 assessments of cardiac catheterisation are completed (where possible including a right and left study)
For each assessment the following documentation must be provided:
Pacing Implant
4 assessments of pacing implant are completed.
For each assessment the following documentation must be provided
Pacemaker Follow-Up
4 assessments of pacemaker follow-Up are completed
For each assessment the following documentation must be provided:
Echo
4 assessments of echo are completed. For each assessment the following
documentation must be provided
Evidence Portfolio
Evidence must be presented for EVERY investigation
Patient ID must be removed from ALL evidence (all pages not just front sheet)
Resting ECG x150
Put ECG report on the left
If possible make report sheet landscape so scrutineer can read report whilst looking at ECG
Put ECG on the right
Cardiac Catheterisation
Copy of pressures and haemodynamics with measurements which have been checked by WBA