MLT, CLD & FID Gas Analyzer Series
Visualize > Analyze > Optimize
+
+
2
Modular and User-Friendly Process Analysis
GET MORE OUT OF YOUR PROCESS GAS ANALYZER
Emerson
Multi-MethodEmerson Rosemount Analytical’s MLT, CLD and FID Gas Analyzer Series offers non-dispersive infrared, ultraviolet, visible photometry (NDIR/UV/VIS), electrochemical or paramagnetic oxygen sensors (eO2 / pO2) and thermal conductivity (TC) sensors, chemiluminescence (CLD) and flame ionization (FID) detectors.
Multi-Channel MLT gas analyzers continuously measure up to five components in a single enclosure.
Stand-alone or NetworkedMLT, CLD and FID Gas Analyzers can be designed as flexible stand-alone analyzers consisting of a platform with MLT, CLD or FID analyzer module plus analog and digital I/O boards. MLT Gas Analyzers can alternatively be built up as fix stand-alone analyzer complete with control module functionality and display/ operator interface - or as a central interface for multiple Analyzer Modules with a network board. In MLT/CLD/FID Analyzer systems, this feature eliminates multiplication of the display/operator interface and features significant cost and system packaging advantages.
Comprehensive CommunicationMLT Gas Analyzers offer multiple programmable I/O’s,LON network connection, serial interfaces, DeltaV and Foundation™ fieldbus connectivity.
Broadest Packaging OptionsMLT Gas Analyzers offer general purpose table-top or rack-mount packaging from portable ½ 19'' with external power supply to 19'' with internal or external power supply. Wall-mountable single or dual compartment field housings made of stainless steel are available for outdoor installations.
High Protection ClassMLT 2 field housing is designed as single or dual compartment enclosure to operate in rough environments. With IP65 protection class, the MLT 2 is proven to withstand wet and heavy-dust conditions, as well as temperature swings.
Hazardous Area SolutionsMLT 2 field housing can be fitted with Z purge pressurization systems to be operated in hazardous areas classified as Division 2.
Best Service AnalyzerRosemount Analytical redefines analyzer standards
Chopper - MLT
NDIR/UV/VIS Principles
CLD Chemiluminescence ReactionFID Principle
O2 MoleculeVent
NO Molecule
Phot
odio
de
NO
Ozone
Ozone Molecule NO2 Molecule(excited state)
NO2 Molecule(emitting red light)
Paramagnetic Oxygen Principle
3
N e t w o r kBuild a Network of Analyzer Modules
MLT, CLD and FID Analyzer Modules (AM’s) are “blind”
analysis units but retain all the advanced design
features. MLT, CLD and FID AM’s are designed with metal
housings. Additionally MLT AM’s are also available as
rack-mount/ table-top enclosures or as wall-mountable
field housings. MLT, CLD, FID, H(ot)FID and T(hermo)FID
AM’s can be linked into NGA systems via platform or
MLT analyzer (MLT 1, 2, 3, 4).
Based on a typical MLT Analyzer or Platform, the schematic illustrates the simplicity of a networked system.
4
SUPERIOR PERFORMANCE
Operating Beyond ExpectationsEmerson
Emerson Rosemount Analytical analysis solutions range from single gas analyzers including sample handling options, tocomplex, multi-point systems with sample conditioning, data acquisition, analyzer cabinets and complete walk-in analyzer houses to meet customer’s requirements.
For applications in hazardous areas, analyzers or even complete analyzer houses can be pressurized. Our leading-edge instruments and application expertise, customer service and worldwide support will help you to maximize process performance, productivity and profitability.
We manufacture MLT, CLD and FID Gas Analyzers for those systems with a wide range of leading-edge technologies such as MLT, which includes measurements from NDIR/UV/VIS to pO2, TCD, and electrochemical sensors to be combined with CLD and/ or FID analyzer modules. Also GC, liquid or combustion solutions such as ZrO2 and combustibles can be supplemental measurement depending on application requirement.
Emerson analyzers and systems can measure more than 60 gas components in both hazardous and general purpose areas with worldwide certifications. Rosemount Analytical analyzer systems are specifically designed for continuous emissions monitoring (CEMS) and process control, and provide much more than only data. They help you to:
> Reduce installation and maintenance costs > Reduce process variability > Improve process diagnostics and safety > Improve product quality > Improve throughput > Meet regulatory requirements
Typical Applications > Gas processing with LNG, Ammonia, Vinyl chloride, Syngas,
Hydrogen, Carbon dioxide plants, and more. > Petrochemical with Ethylene, PE, Aromatics, Butadiene,
Butene plants, etc. > Refining with Cracking, Fluid catalytic cracking unit (FCCU),
Benzene hydrogenation, Crude oil, etc. > Chemical Industry with Bisphenol, Phthalic anhydride,
Terpene, Nylon, Polycarbonates, and Methionine plants and more.
Gas analysis is our business, but our expertise also includes sample handling. In most cases, process gas cannot be taken directly from the process to the analyzer. Nearly all systems demand a level of application specific sample handling. Smart sample handling systems, not affecting the sample gas composition, enable samples to be safely taken from the process, prepared for analysis, and returned to process or approved disposal point.
Whether your design philosophy favors close coupled field mounting of analyzers, or a centralized air purged, air conditioned shelter approach, Rosemount Analytical turn-key analyzer systems can be tailored to your exact needs - without compromise and withproven versatility.
MLT Gas Analyzers’ outstanding feature is their support of up to five measurement channels inside one single enclosure. Photometer, electrochemical, paramagnetic and thermal conductivity principles can be mixed in several configurations. Field housings with up to five compartments enable installation of thermostat controlled components (up to 120 °C as special solution) and internal sample handling options.
MLT Gas Analyzers
5
MLT Specifications
�� Supports MLT, CLD and FID AM’s, Analyzer and systems
� Combination even with X-STREAM Analyzers
� Create calculated channels�� Data visualization system
� Several graphical options such as line diagrams, bar graphs and data tables
� Place measurement data windows on an image of your plant installation
� Enables to see where measurement takes place
Lowest Range Principle
Ultra Low CO2 0–5 ppm IR
Ultra Low CO 0–10 ppm IR
Sulfur dioxide 0–25 ppm UV
Hydrocarbons 0–1 ppm FID
NO/NOx 0–5 ppm CLD
INNOVATION MATTERS
Rosemount Analytical’s MLT gas analyzers feature the outstanding patented Proof Peak technology gas detector with automatic sensitivity control, 30 times per second compensation, longterm stability and high accuracy. Driven by an Eddy current motor, the chopper provides a measuring frequency of approximately 120 Hz for fast response measurements.
WinControl Analyzer SoftwareWinControl by Akrobit, is a third-party software that allows you to connect your computer to the MLT, CLD, or FID gas analyzer or analyzer system and manage it more effectively.
Designed with a standard Windows® user interface in mind, the software functionality is easy to operate and the main programming functions like calibration, the ability to summarize, display and work with your data makes interpreting analysis much simpler. The modular structure of WinControl also allows you to configure your own individual program variant containing the options which are relevant to you. In addition, DDE and OLE standard support allows the integration of different applications with this data acquisition program.
Additional features include:
�� Data acquisition system � Download measurements and events � Calibration protocol with result and
deviation � Event protocol with detailed analyzer
status�� Remote control of MLT, CLD and FID Gas Analyzers
and AMs � Enables remote view of primary and
secondary measurements � Run control functions such as calibration,
range switching or alarm setting�� Check measurement history by an electronic chart
recorder � Transfer of measurement values into
other applications like MS Excel�� Several Communication options
� Via serial interface (RS232/ RS485) � Via modem (cell phone) � Ethernet connection (TCP/IP)
frank schmidt & dirk slobada
6 Flexible, reliable, rugged
INNOVATIVE ANALYSIS AND SOLUTIONS
Comprehensive TestingAllows us to offer the industry’s best standard
Emerson Modular and User-Friendly Process Analysis
1 Detector
Each detector undergoes a helium leak test. Extremely low leakage rates are achieved through the use of a unique glass soldering technique for the detector and special steel cells.
2
4
5Chopper
Each chopper is tested for deviation relating to turning frequency and the possible influence of temperature changes (ambient temperature up to 70 °C). Each chopper wheel is designed with an on-board proof-peak to achieve with any rotation an automatic gain
control resulting in very long span stability.
Linearization
For each measurement requiring a linearization, Rosemount Analytical performs a raw measurement of the data. Next, a linearization curve is calculated. Finally, the functionality of the linearization is validated.
Long-Term
Every analyzer is tested for long term drift stabilty verifying that no abnormal behavior shows up.
3 Climate Chamber
Every analyzer undergoes 48-hour climate testing in an environmental chamber. With this test, the analyzer is optimized for minimum temperature error. This assesses temperature compensation and verifies the overall
performance.
Flexible, reliable, rugged 7
Features Foundation™ fieldbus as well as AK protocol and WinControl over serial interface.
> Shares information between multiple locations> Connects without the use of special converters
Communications Capabilities
Flexible I/O - SIO and DIO
The standard analog SIO board provides up to eight analog outputs. Digital DIO boards offer each eight digital inputs and 24 digital outputs.
The MLT Analyzer or AM allows one SIO and one DIO board while a platform is designed to implement one SIO and up to four DIO boards.
> Control external sample handling> Output alarms> Enables external range switching
Benefits
Sends key data to systems throughout the plant
Requires less engineering time, which translates into lower costs
Requires no additional multiplier with explosion-proof housing
Provides third-party devices with measurement signals
Uses data from the sample handling system to auto correct the analyzed component data
TUEV, QAL 1, GOST (Russia, Belarus) enable measurements according legislative requirements.
> Available for MLT (CO, NO, NO2, SO2 & O2; QAL 1 for N2O) CLD (NO/NOx) TFID (Hydrocarbons)
Suitability Certifications
Offers additional backup capabilities for processes not requiring a full-time connection to the plant DCS
Predicts potential issues by tracking the calibration deviations
Tells precisely when data was pulled with a time-stamp, and allows users to compare collected data
Offers further savings when simultaneous measurements are unnecessary, as one analyzer can conduct measurements at several sample points
Offers the capability for simple updating, including a full update of the
firmware without returning the analyzer to the factory.
Software Update & Maintenance
Allows analyzer software updates in the field
MLT, CLD & FIDGas Analyzer Series
March 2013
PGA_BRO_MLT_CLD_FID_SERIES
©2013 Emerson Process Management. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.
The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
ASIA-PACIFIC
Emerson Process ManagementAsia Pacific Private Limited1 Pandan CrescentSingapore 128461Republic of SingaporeT +65 6 777 8211F +65 6 777 [email protected]
MIDDLE EAST AND AFRICA
Emerson Process ManagementEmerson FZEP.O Box 17033Jebel Ali Free ZoneDubai, United Arab EmiratesT +971 4 811 8100F +971 4 886 [email protected]
EUROPE
Emerson Process ManagementGmbH & Co. OHGRosemount AnalyticalAnalytical Center of ExcellenceIndustriestrasse 163594 Hasselroth, GermanyT +49 6055 884 0F +49 6055 884 [email protected]
AMERICASEmerson Process Management Rosemount Analytical Analytical Center of Excellence10241 West Little York, Suite 200Houston, TX 77040 USA Toll Free 866 422 3683T +1 713 396 8880 (North America)T +1 713 396 8759 (Latin America)F +1 713 466 [email protected]
www.RosemountAnalytical.comwww.twitter.com/RAIhome
www.facebook.com/EmersonRosemountAnalytical
www.analyticexpert.com