The Synergy Of Two Powers
Siemens - the chromatograph leader in the German chemicals industry with 60% market share and 40 years experience.
Applied Automation - the global chromatograph leader in hydrocarbon processing measurement with 30-35% market share and 40 years experience too
THE RESULT: The most powerful and most versatile process gas chromatograph ever! Siemens becomes the largest global GC supplier with 80 years of combined experienceMaxum edition II
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 3; date
Maxum Edition II - The Complete Solution to All GC Requirements!
Siemens Applied Automation
—The One Stop Shop for GCs
Customer’s Savings
— Reduced investment through optimised, versatile and reliable GC solutions
— Reduced engineering through one common platfrom— Reduced procurement time and project management— Short & smooth of start-up through consistent
engineering— Less maintenance and minimum training— Reduced inventory through common spare parts
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 4; date
The Maxum edition II - The Technological BreakThrough!
Ovens
Detectors
Valves and Application Tools
Electronics
Software
Inputs, Outputs and Reports
Human Interface and Workstation
Networking
Power and Versatility in
Every Aspects!
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 5; date
The Most Versatile Analytical Oven that Meets All GC Application Requirements
Airless (1 or 2 ovens) Air Bath (1 or 2 temp sections/zones)
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 6; date
Why the 2 Oven Type, 4 Configuration Choice
Airless (Space Heater)— One or two Independent oven
with separate doors. Independent maintenance
— Space heater does not need instru air. Especially suitable for remote locations. Save upto 500 Euro per GC each year on power & air utilities
— Higher maximum operating temperature beyond 200 deg C and effective thermal efficiency. Oven can also be used for high temp sampling system
Air bath (Air Bath Heater)— Upto two separate temp
section/zone through thermal isolation in one large compartment
— Air bath heater provides fast warm up and stabilization time. Permits programmed temperature or sub-ambient operation with vortex cooling configuration
— Large, spacious compartment for complex applications and easy maintenance
Single Airless Dual Airless Single Air Bath Split Air BathProgrammed Temperature
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 7; date
The Widest Choice and Largest Quantity of Detectors per GC
A total of 7 different technologies in detector modules— 4- and 8-cell Thermal Conductivity with thermistors
(max 24 TCDs for % measurement)— 2-cell Thermal Conductivity with filaments— Flame Ionization or Flame Ionization with Filament TCD
(Max 3 FIDs for ppm HC measurement and 6TCDs for % measurement)
— Flame Photometric (Max 3 FPDs for low sulphur measurement)
— Electron Capture— Helium Ionization— Electrolytic Conductivity
Each Maxum Ed II can effectively replace the job of upto 5 traditional GCs without operation compromise. The cost saving in GC shelters and accessories is upto 70% of total analyzer system cost!
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 8; date
The Benefits of More Detectors - Parallel Chromatography
More detectors allow more applications per oven
— Critical/control service can be measured in unprecedent fast cycle time
— Critical/control service can also have redundant application including oven in one GC
— Complex analyzer can be replaced by Maxum Ed II because of faster analysis time and more components measured eg Mass Spectrometer
S S S R
Column 1
Column 2
1 2109
8
345
7 6
Carrier In from EPC
SampleOut In
SSO
Detector Vents
Fixed Restrictor
0
0.5
1
1.5
2
2.5
3
3.5
4
0.00 5.00 10.00 15.00 20.00 25.00
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0.00 5.00 10.00 15.00 20.00 25.00
0
1
2
3
4
5
6
7
8
9
0.00 5.00 10.00 15.00 20.00 25.00
Traditional SerialChromatography
Maxum ParallelChromatography
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 9; date
The Benefits of More Detectors – Inter-column Detectors, The Siemens Standard Feature!
Adequate detectors ensure that Inter-column detectors are always considered.
Traditionally, detectors take-up oven space, micro-processor power, and incur cost. Therefore, GC vendors do omit inter-column detectors to cut cost.
In a typical GC application, the first column provide coarse separation of the sample. Then the sample is switched to various columns for further specific fine separation. The switching is basically determined by time.
Inter-column detectors eliminate time consuming and tedious guess work when deciding oven flow path switching timing between columns. This happens whenever the columns aged or are replaced.
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 10; date
The Benefits of More Detectors - Power Made Simple
More detectors allow more applications per oven— Two or more streams can be
analyzed in parallel instead of stream switching. Therefore all streams results are updated in each cycle of analysis.
There are enough detectors to standardised and simplify chromatography application methods— Applications are broken down into
simple standardised sub-applications called Applets.
— Applets reduces cost by reducing complexity in user understanding, training and maintenance.
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0.00 5.00 10.00 15.00 20.00 25.00
0
1
2
3
4
5
6
7
8
9
0.00 5.00 10.00 15.00 20.00 25.00Stream 1Stream 2
Stream 3
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0.00 5.00 10.00 15.00 20.00 25.00
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 11; date
Industry Leader in Oven Switching Valve Choice and Reliability
Extremely high reliability and long life diaphragm valves— 10-port Plunger-less diaphragm vapor sample valve— Proven MTBF 10 years.— 6-port Diaphragm-plunger high pressure vapor or
liquid sample valve— Proven MTBF 6 years
Vaporising liquid injection valve— Precision sample size control and fast, clean
injection— Ideally suited for liquid chemical analysis
Valveless, Live column switching— Essentially zero dead volume, precise sample size
for fast column switching and sample injection with capillary columns
— No parts to fail or wear out
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 12; date
The Winner in Electronics Power & Processing Speed
Upto 4 32-bit 486 electronic processors with internal serial signal distribution— 1 x 486 32-bit Dedicated System
Controller for communications, human interface and database management
— Upto 3 x 486 32 bit Dedicated Sensor Controllers for detector data acquisition; independent controllers for each detector module.
— Plug and Play technology
— TCP/IP platform
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 13; date
Carrier Gas Pressure Control is a Standard Not an Option!
Upto 8-channel Electronic Pressure Control— Absolute digital control of carrier gas
pressures. No more tedious flow adjustment on site start-up and routine maintenance.
— The GC oven always involves various carrier gas flow paths to different analysis columns. The source carrier gas pressure therefore varies because different columns have different length and separation time.
— Traditionally, needle valves are used as restrictors to vary the source carrier gas pressure. These needle valves always creep during transportation and overtime requiring frequent tedious flow adjustment maintenance.
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 14; date
The Only MMI that Replaces the Traditional Chromatogram Recorder in Zone 1/Div 1 Areas
Unique feature allowing Zoom, Pan function on any area of a Chromatogram; Display detector signals value and retention time
Memory for 8 hour storage of Chromatograms in GC. Infinite memory storage with network PC workstation
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 15; date
The Only Process GC with EZ Chrom Software!
Embedded Advance EZChrom brings laboratory capabilities to the process environment
Windows Based with tools bars, user friendly requiring minimum training to operate
Powerful real time distributed database integrates all analyzer functions into the underlying architecture
Flexible and extensible functionality available through user programming using MaxBasic programming language
The Maxum Ed II gives you a warning alarm when your columns starts
degrading
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 16; date
A Full Range Of Signal I/Os from GC
Discrete Input and Output devices— Isolated Analogue outputs— Analogue inputs— Digital inputs and outputs
Local control of serial report printers
Local output of Modbus serial communication
In addition, all capabilities are extended by Networking
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 17; date
Full Workstation Capability with PC
System Manager— Complete network overview and
monitoring with analyzer status
EZChrom— Full access to embedded analyzer
EZChrom method— Convenient multi-window chromatogram
displays— Easy method creation and editing
Numerous other maintenance tools— Backup, restore, update— Data Logger— APC 8.1 for compatibility with Optichrom Advance
Multiple workstations permitted on network; compatible with telephone or LAN connection for remote access
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 18; date
Versatile and Open Networking, Just Like Your Office PCs!
All Maxum edition II GCs connect to a high speed network—Direct GC-to-GC communications; no PC, server or
other “network controller” device required
Three communication options available to allow systems to be designed for lowest cost and highest performance—Ethernet—DataNET—Data Hiway
Full backwards connectivity to Optichrom Advance
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 19; date
Versatile and Open Networking, Just Like Your Office PCs!
Maxum II Sales Introduction.ppt
s
© Siemens Applied Automation, 2001Slide 20; date
Maxum Edition II The Optimised & Cost Saving GC
Solution for the Future! Siemens Applied Automation
—The One Stop Shop for GCs
Customer’s Savings
— Reduced investment through optimised, versatile and reliable GC solutions
— Reduced engineering through one common platfrom— Reduced procurement time and project management— Short & smooth of start-up through consistent
engineering— Less maintenance and minimum training— Reduced inventory through common spare parts