LEGEND
Limit of Work Line
Concrete Paving: See Civic Plans. Color and finish to match existing concrete
flatwork. EJ = Expansion Joint. Other joints are Weakened Plane Joints UON.
Permeable Concrete Pavers: See Civil Plans. Color Brown, Hydroflow Estate,
80mm, Basketweave Pattern.
Concrete Band: Color & Finish to match concrete paving. See Civil Plans.
Planting Area: See Planting Plan
EJ
PA
LOW
L
O
W
LO
W
LO
W
LO
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
PA
PA
PA
PA
PA
1
3
6
7
8
9
10
4
TYP. of (4)
3
6
5
2 TYP. of (18)
TYP. of (2)
PA
REFERENCE NOTES
Portland Loo Restroom Building: See Architectural Plans.
Future Restroom Building
Existing Bench: See Civil Plans.
Wall Mounted Trellis: See
Bench: Victor Stanley FRB-6, 8' long, color TBD., with intermediate armrests. See
Existing Column
Building : See Architectural Plans.
Existing Sidewalk
Existing Seatwall
Existing Lawn
1
2
3
4
5
6
7
8
9
10
/L-1.01
/L-1.02
GENERAL NOTES
1. CODES
1. Walking surfaces shall comply with CBC 11B-403 Walking Surfaces. All finishes shall be
slip resistant.
2. CONTROL JOINTS: PEDESTRIAN CONCRETE PAVING
1. Expansion Joints: locate as shown on the Plans; if not shown then at
maximum 60’ O.C. in any direction. Locate at all building faces, walls, steps, ramps, and
other site structures. See typical joint detail. See Specs.
2. Weakened Plane Joints: locate as shown on the Plans; if not shown then at maximum 20'
O.C. in any direction. Joints shall be saw-cut / tooled. See typical joint detail. See Specs.
3. CONTROL JOINTS: CURBS
1. Expansion Joints: align with expansion joints in monolithic paving; at maximum 60' O.C.
when adjacent to modular paving, and at all corners, start/end of radiuses, and
connections to flush curbing. Full depth.
2. Weakened Plane Joints: align with weakened plane joints in monolithic paving; at a
maximum of 20’ O.C. when adjacent to modular paving. Construct across the top and
visible face.
4. UTILITIES
1. Rectangular utility boxes shall be installed parallel to curbs / edges of sidewalks. Boxes in
plaza paving areas shall be installed parallel to jointing patterns. Review locations in the
field with the Engineer prior to installation
C
BENCH POST: 3 PER BENCH TYP. SEE SPECS.
A
COMPACTED SUBGRADE, SEE SPECS
B
BEDDING SAND: SEE SPECS
CONCRETE FOOTING
PIPE SUPPORT EMBEDMENT TABLE
SINGLE
SF GRILL
DUAL
SF GRILL
PEDESTAL
TABLE
PICNIC
TABLE BENCH
BIKE
LOOP
A 12" 12" 18" 21" 12" 12"
B 30" 36" 36" 24" 24" 24"
C 6" 12" 6" 6" 6" 12"
AGGREGATE BASE: SEE SPECS
CONCRETE PAVER: HYDROFLOW ESTATE, SEE CIVIL PLANS.
7"
1'-6
"1
'-6
"3
"
MA
X.
MA
X.
VINE: SEE PLANTING PLAN.
3/8" x 5" HDG LAG BOLT DRILLED
AND SET INTO WALL. PROVIDE
NUT AT FACE OF WALL AND BACK
OF PANEL.
BUILDING WALL
WELDED WIRE MESH: 4" WELDED
GALV. STEEL WIRE - 11 GAUGE.
PAINTED TO MATCH BUILDING.
BUILDING WALL
STEEL BAR FRAME
PLANTING AREA: SEE PLANTING
PLAN. PROVIDE A MIN. 12"X12"X18"
DEEP SOIL POCKET WITH
DRAINAGE TO NATIVE SOILS.
1/8" X 1" WIDE STEEL BARS ON
BOTH SIDES OF MESH.
SCALE: 1"= 8'-0"
8 0 8 16
1
NTS
Wall Mounted Trellis
L-1.0
CONSTRUCTION
PLAN
17.115
06/25/18
THE
P
PARTNERSHIP
AUL DAVIS
AR HIC TECTS & PLANNERS
The Paul Davis Partnership, LLP
286 Eldorado Street
Monterey, CA 93940
(831) 373-2784 FAX (831) 373-7459
EMAIL: [email protected]
NEW EMPLOYEE BREAKROOM
SALINAS TRANSITCENTER ADDITION110 SALINAS ST.SALINAS, CA 93901A.P.N.
JB
Signature
Renewal Date
Date
B
EL
L I N
G
E
R
N
O
.
L
A
N
DS
CAP
E
A
R
C
H
I
T
E
C
T
D
E
S
N
E
CI
L
E
.
MIC
H
A
E
L
3
0
99
S
T
A
T
E
O
F CA
L
I
F
O
R
N
I
A
12-31-19
11-06-18
2
NTS
Bench Footing Embedment in Pavers
SA
LIN
AS
ST
RE
ET
L
O
W
LO
W
LO
W
LO
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
C
E
N
TR
A
L A
V
E
N
U
E
B
POC
02
01
(E)
SOAKER
01
1" 2
DRIP
02
1" 0.9
LEGEND
SYMBOL MANUFACTURER DESCRIPTION
Existing Main Line:
Main Line: Size to match existing.
Lateral Line / Drip Irrigation Supply Line: 18" min. cover, 24"
under AC paving Sch/Class per Specs. See chart for size.
Stub Out: See Irrigation Details
Rainbird / Hunter / Toro
PEB / ICV / P-220 Remote Control Valve: Size as shown on
plan.
Rainbird / Toro
3/4" / 1" Quick Coupler. Single lug, 2-pc body, locking cover.
King Brothers (kbi)Full Port, True Union, PVC Ball Valve: Line Size
None
King Brothers (kbi)
Full Port, True Union, PVC Ball Valve: Line Size, at solenoid
/ manifolds and quick coupler shut-offs UON.
Existing Backflow Preventer
B(E)
LEGEND - DRIP IRRIGATION
SYMBOL MANUFACTURER DESCRIPTION
POINT-SOURCE: 1" dia. PE supply pipe & 1/4" I.D. PE
distribution tubes. See drip irrigation schematic diagram. See
Specs. See Irrigation Details.
Emitters: 2.0 GPH pressure compensating w/ bug/dust cap.
Rainbird Xeri-Bug / Toro NGE / Netafim WPC. Toro
T-DL-MP9 Indicator w/ flush valve at end of each zone.
Rainbird / Hunter
PEB / ICV Remote Control Valve: Size as shown on plan.
Non-potable version.
Netafim
Disc Filter, 120-140 mesh
3/4" @ 1" valves or 17 GPM max at manifold
1" @ 1-1/2" valves up to 26 GPM max
1-1/2" @ 1-1/2" valves or 35 GPM max at manifold
Netafim / Toro / Rainbird
In-line Pressure Regulator:
Netafim 3/4" LF 42 PSI (3.0 Bar) @ valves < 4.5 GPM; 3/4"
HF 45 PSI (3.0 Bar) @ valves > 4.5 GPM. Toro 3/4" 40 PSI
MF / Rainbird 3/4" 40 PSI @ valves 2-10 GPM.
Netafim 1-1/2" 45 PSI (3.0 Bar) @ valves 11-35 GPM
Soaker Hose: Mr. Soaker Hose, Green Stripe Pro, 5/8" I.D.
Requires 20/25 PSI (1.4/1.8 Bar) preset pressure regulator.
Specifications and General Notes for equipment conformance to recycled water regulations.
(ZONE 00)
01
Zone designation
1. GUARANTEE:
Guarantee the irrigation system for one year from date of acceptance.
2. VERIFICATION:
For existing systems design is based on 60 PSI available, and 50 GPM allowable based on pipe
size, at discharge outlet of point of connection. Verify same and notify Owner's Representative if
such data adversely affects the operation of the system. Such notice shall be made in writing
and prior to commencing any irrigation work.
3. UTILITIES:
Verify location of all on-site utilities. Preserve and protect all such utilities unless otherwise noted.
Restore damaged utilities to the satisfaction of the Owner's Representative, and at no additional
cost to the Owner.
4. EXISTING IRRIGATION
Raise or lower existing irrigation assemblies and boxes, unless noted to be demolished, to
proposed grades and install as shown on the Irrigation Details, at no additional cost to the Owner.
Maintain and troubleshoot existing irrigation circuits and valves in use and noted to be preserved,
throughout the construction period at no additional cost to the Owner.
5. SCHEMATIC:
System features are shown schematically for graphic clarity. Install all piping and valves in
common trenches where feasible and inside planting areas adjacent to walkways and inside
medians whenever possible.
6. SPECIFICATIONS:
See irrigation specifications for additional information.
7. CODES:
Irrigation system shall be installed in accordance with all local codes and manufacturer's
specifications. Notify Owner's Representative by telephone and in writing of any conflicts prior to
installation.
8. MASTER VALVE / FLOW SENSOR:
a. Connect master valve, and flow sensor if included, to controller with communication cable.
See Irrigation Details. Install in dedicated 1" diameter PVC conduit.
b. Normally closed Master Valves: dedicated one station to quick coupler use.
c. Flow sensors: See Specifications for instructions on how to program irrigation controller to
allow flow sensor to accommodate quick coupler use.
8. VALVES:
a. For tree bubbler zones, include the MFR's adjustable pressure regulating dial.
b. For battery operated controllers, include the MFR's DC latching solenoid.
9. QUICK COUPLING VALVES:
Install on double swing joint. Locate 12" away from edge of walks, walls, curbs, and
headerboards within planting areas. Provide one swivel, hose ell.
10. CHECK VALVES:
Install in-head check valves for sprinklers, and in-line check valves in drip irrigation supply lines,
as required to minimize line drainage. Allow in bid price an amount sufficient to provide and install
additional check valves to accommodate any necessary field changes.
11. BORING
Jet bore or directional bore under existing rigid paving areas. Do not trench across unless
specifically shown on the Drawings and/or approved in writing by the Owner's Representative.
12. SLEEVING:
Sch. 40 PVC pipe for all wiring and irrigation lines installed under paving areas and that pass
through drainage trenches with drain rock. 4-inch dia. or twice the aggregate diameter of all pipes
contained within the sleeve, whichever is greater. Install (with ends clearly marked above grade)
at the necessary depth prior to the construction of paving areas or field bases. Sleeving to
extend 12" from edge of paving or drainage trench into adjacent subgrade. No unsleeved piping,
angle-bends, 90-degree bends, or joints shall be allowed under paving.
13. DRIP VALVES
Group drip valve run times together to ensure a minimum flow of 2 GPM as required by the flow
sensor. Suggested grouping chart will be provided prior to Final Completion.
21. CONTROLLER:
Existing Controller. All above-grade conduit shall be rigid steel securely fastened to structure and
to controller.
22. PROGRAMMING / SCHEDULING:
a. Non-ET Controllers: Prior to the end of the maintenance period, schedule the controller for
repeat cycle irrigation and multiple programs.
b. ET Controllers: Prior to the end of the maintenance period, program the controller per
manufacturer's directions.
c. Adjust irrigation times for bio-retention soil areas to account for higher percolation rates
d. For sprinklers, provide at least two start times for shrubs if over 5 minutes in length for any
one station. Shrubs shall be separated into two programs, one for sun valves, one for
partial shade to shade valves.
23. FLUSH (E) MAIN:
Upon completion of connection to (E) main, allowing for solvent setup, flush main line and
existing main by flushing nearest quick coupler downstream of P.O.C. on existing main.
GENERAL NOTES
DRIP IRRIGATION POINT SOURCE TYP. SCHEMATIC DIAGRAM EMITTER SCHEDULE
See planting plan for plant sizes and locations. PE supply pipe and PE
distribution tube alignments per requirements of planting. Install
emitters per Emitter Schedule, and allow for additional ports to each
plant for future needs. Locate emitters towards the uphill side of plants
on slopes. See irrigation details.
1 gal.
1
5 gal.
2
15 gal.
3
24" box 4
PE Supply Pipe: Max 200-ft
/ flow 12 gpm. See Specs
Up to (4) emitters per plant.
See Emitter Schedule. See
Irrigation Details.
PE Distribution Pipe: Max 5-ft.
See Specs.
In-line Check Valve: See Specs
(for sloped areas if present)
Branch layout for different
directions/areas as required
PVC pipe and sleeve under
paving areas
TYPICAL LAYOUT
Flush Port & Pressure Indicator,
Typ: See Details
TYPE
X
X X
Valve
Station
GPM
Valve
Size
Irrigation
Type
Limit of Work Line
Point of Connection
POC
Note: Where applicable, all equipment specified shall be non-potable versions. See
Specifications and General Notes for equipment conformance to recycled water regulations.
Total irrigated landscape area=0.01 acres. Annual water requirement=0.01 acre-feet
LOW
F:\P
RO
DU
CT
IO
N\P
ro
je
cts\2
01
7\1
7.1
15
\C
AD
\1
71
15
_0
3Irrig
atio
n.d
wg
6
/2
5/2
01
8
SCALE: 1"= 8'-0"
8 0 8 16
L-2.0
IRRIGATION PLAN
17.115
06/25/18
THE
P
PARTNERSHIP
AUL DAVIS
AR HIC TECTS & PLANNERS
The Paul Davis Partnership, LLP
286 Eldorado Street
Monterey, CA 93940
(831) 373-2784 FAX (831) 373-7459
EMAIL: [email protected]
NEW EMPLOYEE BREAKROOM
SALINAS TRANSITCENTER ADDITION110 SALINAS ST.SALINAS, CA 93901A.P.N.
JB
Signature
Renewal Date
Date
B
EL
L I N
G
E
R
N
O
.
L
A
N
DS
CAP
E
A
R
C
H
I
T
E
C
T
D
E
S
N
E
CI
L
E
.
MIC
H
A
E
L
3
0
99
S
T
A
T
E
O
F CA
L
I
F
O
R
N
I
A
12-31-19
11-06-18
PLANT LEGEND
Limit of Work Line
*WUC CODE BOTANICAL NAME COMMON NAME SIZE CHARACTER
Trees
M Pc
Pyrus calleryana 'Chanticleer' Callery Pear
15 Gal. Standard
Shrubs
L Lm
Lantana montevidensis 'Spreading White' White Trailing Lantana
1 Gal.
@ 48"
L Sm
Salvia microphylla 'Hot Lips' Hot Lip Sage
1 Gal.
@ 36"
Vines
L Rb Rosa banksiae
Lady Banks Rose
5 Gal.
L
O
W
LO
W
LO
W
LO
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
L
O
W
1
13 Lm
7 Rb
8 Sm
12 Lm
7 Lm
2
2
REFERENCE NOTES
Install turf sod to match existing extents of concrete demolition, assume 60sf.
Root Barrier: See Notes, See
1
2/L-3.04
* WATER USE CATEGORY (WUC) KEY
PLANT, TYP.
BACK OF CURB
OR PAVING
x
x
x
Y
1. FOR SPACING 'X', SEE PLANTING
PLAN LEGEND
2. Y= 1/2X + 12"
GROUNDCOVER SPACING AND PLANTING SETBACK DIAGRAM
WUCOLS Region Applicable to this Project: REGION 1
H = High; M = Moderate; L = Low; VL = Very Low; NL = Species Not Listed
* from: Water Use Classification of Landscape Species,
A Guide to the Water Needs of Landscape Plants (WUCOLS)
Revised 2014, University of California Cooperative Extension, L.R. Costello, K.S. Jones
GENERAL NOTES
1. Landscape Architect to approve plant material BEFORE plant layout commences.
2. Landscape Architect to approve layout of all plants BEFORE planting commences.
3. Apply pre-emergent herbicide to all planting areas, excluding naturalized hydroseed
areas/ See Specifications.
4. Apply post-emergent herbicide to all naturalized hydroseed areas. See Specifications.
5. Prepare, amend, and fertilize existing soil per Specifications. Import topsoil per
Specifications.
6. Pre-mix amendments into soil before backfilling plant pits - do not mix inside pits. Break
large clods into small pieces. See Specifications.
7. Plant shrubs per detail . See Spacing Diagram.
8. Plant and stake trees per detail .
9. Install mulch to all planting areas to 3" thickness. Mulch is to contain less than 1% foreign
matter including soil, weeds, seeds, etc. by dry weight. Mulch to be Redwood or FIr bark
nuggets, 3/4" size. Small Fir Bark mulch by Lyngso Garden Materials, Inc., San Carlos,
CA. or approved other.
10. Install vine mounting per detail
11. See Specifications for Maintenance Period.
12. Install root barrier panels at trees planted within 5' of foundations, walls, and curbs, and in
all planters in paved areas. See Specifications. See
/L-3.02
/L-3.03
FINISH GRADE AT PLANTING: 1-INCH (1")
BELOW PAVING, CURB OR MOWBAND
TRANSITION TO FULL DEPTH MULCH 1/3
WIDTH OF PLANTING BED OR 36"
WHICHEVER IS LESS.
36" MAX
FINISH GRADE AT TURF: 1-INCH (1")
BELOW PAVING, CURB OR MOWBAND
USE EXISTING / STOCKPILED SOIL, AND
IMPORTED TOPSOIL TO MEET FINISH
GRADE REQUIREMENT. SEE SPECS.
1
NTS
Finish Grade
FLAT RUBBER TIES
ROOT BARRIER: INSTALL
1
2
" ABOVE FINISHED GRADE.
SEE
STAKES 12" MIN.
INTO SUB-SOIL
2 LODGEPOLE STAKES
BENDING POINT WHEN NURSERY STAKE IS REMOVED
PLAN VIEW
WIND
TREE STAKE
ROOT BALL
TREE TRUNK
FLAT RUBBER TIES
TOP OF ROOTBALL 1/2" ABOVE BACKFILL FINISH GRADE
BACKFILL MIX
MULCH: SEE NOTES.
PLANT PIT
SEE TABLE
6"
6"
UNDISTURBED SOIL OR COMPACTED
UNAMENDED SUB-GRADE
ROOT BARRIER: INSTALL AT EDGE OF
PLANT PIT, UON
PLANT PIT SIZE TABLE
PLANT
SIZE
PIT SIZE -
ROOTBALL PLUS
1 GAL 6" ALL AROUND
5 GAL 8" ALL AROUND
15 GAL 10" ALL AROUND
24" BOX 12" ALL AROUND
>24" BOX MIN.12" ALL
AROUND
/L-3.03
2
NTS
Tree Planting & Staking
PLANT: SEE PLANTING PLAN
LEGEND. SEE SPECS
FINISH GRADE
BACKFILL MIX: SEE SPECS
6" M
IN
.
MULCH: SEE SPECS
UNDISTURBED SOIL OR COMPACTED
UNAMENDED SUB-GRADE
NOTE: SEE PLANTING PLAN LEGEND
FOR SHRUB / GROUNDCOVER SPACING
DIAGRAM.
PLANT PIT SIZE TABLE
PLANT
SIZE
PIT SIZE -
ROOTBALL PLUS
4"POT 3" ALL AROUND
1 GAL 6" ALL AROUND
5 GAL 8" ALL AROUND
15 GAL 10" ALL AROUND
PLANT PIT
SEE TABLE
TOP OF ROOTBALL 1/2" ABOVE
BACKFILL FINISH GRADE
3
NTS
Shrub Planting
A
A
C
B
PLANTERS IN PAVING
SIZE (A x A)
24" PANELS
4' x 4' 7
5' x 5' 9
6' x 6' 11
RECTANGULAR PLANTERS:
NO. OF PANELS = ((B x 2 + C
x 2)-2)) / 2
OPEN PLANTING BEDS
BOX SIZE 24" PANELS
24" 7
36" 9
48" 11
60" 13
NEW TREES: MIN. (7) 24" PANELS
PER.SIDE
SQUARE IN-GROUND
PLANTER
PARKWAY STRIP OR LINEAR IN-GROUND PLANTER
RECTANGULAR IN-GROUND PLANTER
SEE TABLE FOR NO. OF PANELS
10' O
R LE
SS
4
NTS
Root Barrier
F:\P
RO
DU
CT
IO
N\P
ro
je
cts\2
01
7\1
7.1
15
\C
AD
\1
71
15
_0
4P
la
ntin
g.d
wg
6
/2
5/2
01
8
L-3.0
PLANTING PLAN
17.115
06/25/18
THE
P
PARTNERSHIP
AUL DAVIS
AR HIC TECTS & PLANNERS
The Paul Davis Partnership, LLP
286 Eldorado Street
Monterey, CA 93940
(831) 373-2784 FAX (831) 373-7459
EMAIL: [email protected]
NEW EMPLOYEE BREAKROOM
SALINAS TRANSITCENTER ADDITION110 SALINAS ST.SALINAS, CA 93901A.P.N.
JB
Signature
Renewal Date
Date
B
EL
L I N
G
E
R
N
O
.
L
A
N
DS
CAP
E
A
R
C
H
I
T
E
C
T
D
E
S
N
E
CI
L
E
.
MIC
H
A
E
L
3
0
99
S
T
A
T
E
O
F CA
L
I
F
O
R
N
I
A
12-31-19
11-06-18
SCALE: 1"= 8'-0"
8 0 8 16
SCALE: 1"= 8'-0"
8 0 8 16
2
NTS
Remote Control Valve
5
NTS
Valve Box Installation
8
NTS
Drip Irrigation Emitter Layout
3
NTS
Quick Coupler
6
NTS
Trench & Pipe Installation
9
NTS
Soaker Hose
1
NTS
Isolation (Ball) Valve
4
NTS
Typ. Valve Manifold
7
NTS
Drip Irrigation: PE Tube / Emitter / Flush Port
VALVE BOX W/ BOLT DOWN
LID: SEE SPECS.
PVC SCH. 40 45's W/ NIPPLES AS
REQUIRED, 18" LENGTH, TYP.
PVC SCH. 40 COUPLING TYP.
IRRIGATION SUPPLY LINE, TYP.
BRICK BLOCKING: ALL CORNERS / 2 PER ROUND BOX
RODENT PROTECTION SCREEN: 1/2" X 1/2" 19 GA.
WWM WRAP ENDS OF SCREEN
1/2" CLEAN DRAIN ROCK: BRICK DEPTH
FINISH GRADE. SEE SPECS
FOR RELATION TO TOP OF
VALVE BOX
SA
ME
D
EP
TH
A
S IR
RIG
AT
IO
N
SU
PP
LY
L
IN
E
COMPACTED SUBGRADE
NOTE: ATTACH RECYCLED WATER
WARNING TAG TO VALVE STEM, TYP.
TRUE UNION BALL VALVE:
INSTALL W/ HANDLE @/TOP
12
"
2-1/2" & 3" VALVES: INSTALL HANDLE
@ SIDE. INSTALL VALVE BOX
EXTENSIONS FOR MINIMUM 2-INCH
CLEARANCE BELOW HANDLE TO
FACILITATE TURNING
VALVE BOX W/ BOLT DOWN LID: SEE
SPECS. EPOXY / PASTE / RIVET /
BRAND VALVE ID # ON BOX
NOTES:
1. ONE REMOTE CONTROL VALVE ASSEMBLY
PER VALVE BOX.
2. ONE BALL VALVE PER REMOTE CONTROL
VALVE / PER VALVE MANIFOLD
1/2" CLEAN DRAIN ROCK: BRICK DEPTH
SOLENOID VALVE: SEE IRRIGATION
LEGEND
2
SCH. 40 PVC UNION
SCH. 40 MALE TXS ADAPTER. NOTE: BUSH
UP OR DOWN HERE FOR TRANSITIONS TO
LATERAL LINE SIZES
SCH 40 P.V.C. LATERAL
MAINLINE FITTING
MAINLINE / SUBMAIN: SEE SPECS
SCHEDULE 40 P.V.C. NIPPLE
(LENGTH AS REQ'D), TYP.
WATER PROOF CONNECTORS
W/ WIRE NUTS
VALVE ID TAG WITH ID #: SEE SPECS.
VALVE WIRE: 36" IN LOOSE COIL
BALL VALVE: LINE SIZE. SEE VALVE
MANIFOLD DETAIL
SCH. 40 PVC 90° ELBOW
SCH. 40 PVC UNION
12
"
LA
TE
RA
L D
EP
TH
BRICK BLOCKING: ALL CORNERS
FINISH GRADE. SEE SPECS FOR
RELATION TO TOP OF VALVE BOX
RODENT PROTECTION SCREEN: 1/2" X 1/2"
19 GA. WWM, WRAP ENDS OF SCREEN
NOTE: ATTACH RECYCLED WATER
WARNING TAG TO VALVE STEM, TYP.
MFR. ADJUST. PRESSURE REGULATING
DIAL (TREE BUBBLERS ONLY UON)
NOTES:
1. GROUP QUICK COUPLER WITH REMOTE CONTROL VALVES FOR USE OF COMMON
ISOLATION VALVE. SEE TYPICAL MANIFOLD DETAIL.
2. SCHEDULE 80 PRE-ASSEMBLED SWING MAY BE USED .
3. DO NOT INSTALL DIRECTLY ON TOP OF LIVE WATER MAINS.
BALL VALVE: SEE
SCH 80 PVC NIPPLE SxS
PVC SUBMAIN
PVC MAIN
SUPPLY LINE
VALVE BOX W/ BOLT DOWN LID:
SEE SPECS.
QUICK COUPLER VALVE : SEE
IRRIGATION PLANS
2" ANGLE IRON X 24" LONG W/
STAINLESS PIPE CLAMP
4" LONG SCH 80 PVC RISER
2" SCH 80 STREET ELLS
KING BROS OR APPROVED EQUAL
SPEAR: SCH 80 1x12 OR 3/4x12
SCH 80 STREET ELL
SCH 80 TEE
FINISH GRADE. SEE SPECS FOR
RELATION TO TOP OF VALVE BOX
PVC SUBMAIN
SCH 80 PVC NIPPLE
SxS
BRICK BLOCKING, TYP: 2
PER ROUND BOX
1/2" CLEAN DRAIN ROCK:
BRICK DEPTH
RODENT PROTECTION SCREEN:
1
2
" X
1
2
" 19
GAUGE WWM, WRAP ENDS OF SCREEN
VALVE BOX W/ BOLT DOWN LID:
SEE SPECS.
BRICK BLOCKING, TYP.
1/2" CLEAN DRAIN ROCK: BRICK DEPTH
RODENT PROTECTION SCREEN:
1/2" X 1/2" 19 GA. WWM, WRAP
ENDS OF SCREEN
NOTE: ATTACH RECYCLED WATER
WARNING TAG TO VALVE STEM, TYP.
/L-X.XX
12
"
NOTE:
1. REFER TO APPLICABLE CODES FOR MAINLINE DEPTH UNDER ROADWAYS
2. SERPENTINE ALL PLASTIC PIPING.
3. LATERAL SEPARATION DISTANCES SHOWN ARE MINIMUMS UON.
4. SEE SPECIFICATIONS FOR TRENCH BACKFILL.
5. ALL WIRES SHALL BE TAPED AND BUNDLED AT 10' INTERVALS IN TRENCHES.
ELECTRICAL LINE IN
CONDUIT TO BE
INSTALLED
IN ACCORDANCE
WITH ALL
APPLICABLE CODES
3" 3" 3"
VALVE BOXES: SEE SPECS
QUICK COUPLER BOX
ALIGN
REMOTE CONTROL VALVE BOX
PGA
A16
VALVE TYPE: MFG MODEL NUMBER. GLUE
IDENTIFICATION PLATES TO COVER
VALVE BOX COVER: SEE SPECS
CONTROLLER / STATION (VALVE ID#): SEE
SPECS
EDGE OF PATH OR WALL
SHUT OFF VALVE BOX
QC
SOV
12" MIN 12" MIN
12
"
FINISH GRADE
LATERAL LINE
CONTROL WIRES
TAPED INTO BUNDLE
@ 10' INTERVALS
PRESSURE MAINLINE
SUBGRADE
FINISH GRADE
METALLIC LOCATING
TAPE ABOVE PIPE, TYP.
(WHEN REQUIRED BY
CITY OR LOCAL CODES)
PRESSURE MAINLINE
SUBGRADE
COMPACT BACKFILL
FINISH GRADE
SUBGRADE
SERPENTINE ALL PLASTIC PIPING
18
" M
IN
24
" M
IN
24
" M
IN
VARIES
24
" M
IN
MAINLINE
JOINT TRENCH
ELECTRICAL CONDUIT
6" MIN.
3"3" MIN.
TRENCH WALL
TRENCH WALL
NOTE:
MAX. 3 REMOTE CONTROL VALVES PER ISOLATION SHUT-OFF VALVE.
SUB MAINS MAY TRANSITION TO CLASS 315 PVC FROM MAINLINES THAT ARE RING-TITE PVC PIPE.
NOTE:
1. ALL VALVE BOXES MUST BE IDENTIFIED WITH A VALVE ID # ON BOX: SEE SPECIFICATIONS FOR ACCEPTABLE METHODS.
2. VALVE BOXES SHALL HAVE 12" CLEARANCE FROM STRUCTURES AND ANY CONCRETE AREAS. SET BOXES PARALLEL
TO EACH OTHER AND PERPENDICULAR TO CONCRETE, SOUND WALL, HEADERBOARD, ETC.
2. SET BOXES 1-1 /2" ABOVE FINISHED GRADE IN MULCH-COVERED AREAS. SET BOXES 1/2" ABOVE GRADE IN TURF AREAS. BOXES
TO BE PERPENDICULAR TO FINISH GRADE.
3. SET VALVE BOX ASSEMBLY IN GROUND COVER / SHRUB AND NOT IN SIDEWALK OR ROADWAY. INSTALL IN LAWN ONLY
IF GROUNDCOVER DOES NOT EXIST ADJACENT TO LAWN.
4. INSTALL EXTENSION BY VALVE BOX MANUFACTURER AS REQUIRED TO COMPLETELY ENCLOSE ASSEMBLY FOR EASY ACCESS.
5. RECTANGULAR VALVE BOXES SHALL HAVE 4 BRICKS INSTALLED, ONE UNDER EACH CORNER. ROUND VALVE BOXES SHALL
HAVE 2 COMMON BRICKS INSTALLED, AT OPPOSITE SIDES. BRICKS SHALL NOT BE PLACED OVER ANY PIPE OR ITEM THAT COULD
FAIL DUE TO BRICK PLACEMENT.
6. AVOID HEAVILY COMPACTING SOIL AROUND VALVE BOXES TO PREVENT COLLAPSE AND DEFORMATION OF VALVE BOX SIDES.
REMOTE CONTROL VALVE,
TYP.
INDIVIDUAL ISOLATION
VALVES NOT REQUIRED
WHEN VALVES ARE
INSTALLED IN MANIFOLD
MANIFOLD MAIN: MATCH
MAINLINE SIZE UP TO VALVES
SUBMAIN: MATCH MAINLINE
SIZE UP TO VALVES
MAINLINE
DRIP IRRIGATION SINGLE MANIFOLD, TYP.DOUBLE MANIFOLD, TYP. (SINGLE MANIFOLD SIM.)
ISOLATION VALVE, TYP.
10' MIN. UON
QUICK COUPLER VALVE,
DOWNSTREAM OF
VALVES TYP. WHERE
SHOWN ON PLANS
12
"
BEDDING MATERIAL:
SEE SPECS
12
"
BEDDING MATERIAL:
SEE SPECS
BEDDING MATERIAL:
SEE SPECS
12
"
18" MAX18" MAX
REMOTE CONTROL VALVE, TYP.
INDIVIDUAL ISOLATION VALVES,
FILTERS, AND REGULATORS
NOT REQUIRED WHEN VALVES
ARE INSTALLED IN MANIFOLD
FILTER & PRESSURE REGULATING
VALVE: SIZE EACH FOR MAXIMUM
FLOW THROUGH MANIFOLD
ISOLATION VALVE, TYP.
SUBMAIN: SIZE FOR MAXIMUM
FLOW THROUGH MANIFOLD
MAINLINE
MANIFOLD MAIN: SIZE FOR MAX
FLOW THROUGH MANIFOLD
QUICK COUPLER VALVE,
DOWNSTREAM OF VALVES TYP.
WHERE SHOWN ON PLANS
PC EMITTER, SELF FLUSHING w/
BUG/DUST CAP: SEE IRRIGATION
PLAN LEGEND. INSTALL EMITTER
FLUSH WITH PLANTING SOIL.
1/4" PE DISTRIBUTION TUBE: MAX 5-FT.
SEE SPECS. SEE IRRIGATION PLAN
PLANT BASIN
TRANSFER BARB
4"
FINISH GRADE. SEE SPECS FOR
RELATION TO TOP OF VALVE BOX
10" ROUND PLASTIC VALVE BOX
W/ BOLT DOWN LID: SEE SPECS
BRICK BLOCKING: 2 PER ROUND BOX
RODENT PROTECTION SCREEN:
1/2" X 1/2" 19 GA. WWM, WRAP
ENDS OF SCREEN , TYP.
1/2" CLEAN DRAIN ROCK: BRICK DEPTH
COMPACTED SUBGRADE
COMPR. FITTING & SLIP ADAPTER
1/2" PVC HOSE: COIL 2' IN BOX
BALL VALVE, LINE-SIZE: SEE SPECS
3/4" PE SUPPLY PIPE: MAX
LENGTH 200-FT. SEE SPECS.
TO REMOTE CONTROL VALVE
OR PVC LATERAL IF SHOWN ON
IRRIGATION PLAN
6" GALV. STEEL STAPLE, SEE SPECS.
PRESSURE INDICATOR: SEE
IRRIGATION PLAN LEGEND. INSTALL
SO THAT INDICATOR IS CLEARLY
VISIBLE ON TOP OF MULCH.
36" BOX TREE
MIN. 15' HOSE LENGTH
AT ROOTBALL
PVC ELBOW
NIPPLE AS
REQD.
SOAKER HOSE W/ FEMALE HOSE
END FITTING. SEE INSET FOR
LAYOUT. SEE SPECS.
PVC LATERAL OR PE SUPPLY
PIPE FROM DRIP ZONE VALVE
SOAKER HOSE: INSTALL ON
GRADE AT EDGE OF ROOT
BALL. COVER W/ MULCH PER
SPECIFICATIONS
4"
24-IN BOX PLANT
LOCATE 4 EMITTERS AT
MIDPOINT BETWEEN THE
EDGE OF THE ROOTBALL
AND TRUNK AS SHOWN
1-GALLON PLANT
LOCATE 1 EMITTER AT
MIDPOINT BETWEEN THE
EDGE OF THE ROOTBALL
AND TRUNK AS SHOWN
5-GALLON PLANT
LOCATE 2 EMITTERS AT
MIDPOINT BETWEEN THE
EDGE OF THE ROOTBALL
AND TRUNK AS SHOWN
15-GALLON PLANT
LOCATE 3 EMITTERS AT
MIDPOINT BETWEEN THE
EDGE OF THE ROOTBALL
AND TRUNK AS SHOWN
MULCH PLANTING BASIN IF
REQD. FOR HAND WATERING
FINISH GRADE
PVC RISER
PVC SUPPLY
LINE
48" BOX TREE
MIN. 22' HOSE LENGTH
AT ROOT BALL
NOTES:
1. SEE IRRIGATION LEGEND FOR EMITTER GPH AND CONNECTION METHODS TO SUPPLY LINE
2. SEE SPECS FOR SUPPLY & DISTRIBUTION PIPE
3. FOR PLANTS LARGER THAN 24" BOX, USE SOAKER HOSE OR SUB-SURFACE IRRIGATION AS
SHOWN ON THE PLANS.
24" BOX TREE
MIN. 7' HOSE LENGTH
AT ROOT BALL
15 GAL TREE (NOT SHOWN)
MIN. 5' HOSE LENGTH
INSTALLED AT ROOTBALL
12"12"
COUPLING w/ END CAP, TYP.
NIPPLE / FITTING AS REQD.
P.E. SUPPLY PIPE w/ T FITTING
ALTERNATE
DETAIL AT PVC
NOTE:
1. MAX DOWNSTREAM PRESSURE FROM VALVES SHALL BE 15 PSI
SL
OP
E U
P
SL
OP
E U
P
4"
AT SLOPES GREATER THAN 5%
5
"
5
"
5"
5
"
5
"
SL
OP
E U
P
MULCH PLANTING BASIN IF
REQD. FOR HAND WATERING
6" GALV. STEEL STAPLE,
SEE SPECS.
F:\P
RO
DU
CT
IO
N\P
ro
je
cts\2
01
7\1
7.1
15
\C
AD
\1
71
15
_0
5Irrig
&P
la
ntin
gD
eta
ilsD
eta
ils.d
wg
9
/3
/2
01
5
L-4.0
IRRIGATION
DETAILS
17.115
06/25/18
THE
P
PARTNERSHIP
AUL DAVIS
AR HIC TECTS & PLANNERS
The Paul Davis Partnership, LLP
286 Eldorado Street
Monterey, CA 93940
(831) 373-2784 FAX (831) 373-7459
EMAIL: [email protected]
NEW EMPLOYEE BREAKROOM
SALINAS TRANSITCENTER ADDITION110 SALINAS ST.SALINAS, CA 93901A.P.N.
JB
Signature
Renewal Date
Date
B
EL
L I N
G
E
R
N
O
.
L
A
N
DS
CAP
E
A
R
C
H
I
T
E
C
T
D
E
S
N
E
CI
L
E
.
MIC
H
A
E
L
3
0
99
S
T
A
T
E
O
F CA
L
I
F
O
R
N
I
A
12-31-19
11-06-18