N2 NATIONAL ROAD
Dedisa 400kV ESKOM Substation
Dedisa Peaking Power Station
Services Corridor
Port of Ngqura
Zone 13 Power Station
MR435 ROAD
NEPTUNE ROAD
Zone 10Power Station
Grassridge 400kVSubstation
Coega Main132/400 kV Substation
Zone 10 NorthPower Station
LNG Hub
Port Berth
B
C
A
drawing number
201120_Gas-EIA.mxdrevision no.
1
drawing titleCoega SEZ- Gas to Power Overview Map
Coega Business CentreCnr Alcyon road & Zibuko streetZone 1, Coega IDZPort Elizabeth, 6100
scale
Tel: 041-4030471Email: [email protected]
serviceprovider
1:50 7420 640 1 280 1 920 2 560320
Meters
drawn by date referenceM Gcukumana 2020/11/20 CDCGIS02/GIS/COEGA/
201119_Gas-EIA.mxd
projectCoega SEZ
Gas to Power Map
.
checked by
OverviewCoega SEZ
Zone 14
Zone 8
Zone 6
Zone 11
Zone 10
Zone 5
Zone 7
Zone 12
Zone 9
Zone 1Zone 2
Zone 13
Zone 4Zone 3
ÜLegend
Substation CentroidZone BoundariesPotable WaterPort of Ngqura BoundaryDesalSpecies of Special ConcernRoad ReservesRiparian ZoneStormwater StructuresOSMP- No Go AreasServices Corridor
.
Site X YA 62818,61173 -3735200,807B 58674,4097 -3732860,002C 60983,48322 -3738936,155
Substation (Coordinates)
Dedisa 400kV ESKOM Substation
Dedisa Peaking Power Station
Services Corridor
Zone 13 Power Station
MR435 ROAD
A
drawing number
201120_Gas-EIA.mxdrevision no.
1
drawing titleCoega SEZ- Gas to Power Zone 13 Map
Coega Business CentreCnr Alcyon road & Zibuko streetZone 1, Coega IDZPort Elizabeth, 6100
scale
Tel: 041-4030471Email: [email protected]
serviceprovider
1:11 2780 140 280 420 56070
Meters
drawn by date referenceM Gcukumana 2020/11/20 CDCGIS02/GIS/COEGA/
201119_Gas-EIA.mxd
projectCoega SEZ
Gas to Power Map
.
checked by
OverviewCoega SEZ
Zone 14
Zone 8
Zone 6
Zone 11
Zone 10
Zone 5
Zone 7
Zone 12
Zone 9
Zone 1Zone 2
Zone 13
Zone 4Zone 3
ÜLegend
Substation CentroidZone BoundariesPotable WaterPort of Ngqura BoundaryDesalSpecies of Special ConcernRoad ReservesRiparian ZoneStormwater StructuresOSMP- No Go AreasServices Corridor
.
Site X YA 62818,61173 -3735200,807B 58674,4097 -3732860,002C 60983,48322 -3738936,155
Substation (Coordinates)
R
i
n
g
R
o
a
d
S
u
b
s
t
a
t
i
o
n
O
P
E
N
S
P
A
C
E
5
.
5
h
a
5
.
1
h
a
S
e
r
v
i
c
e
s
:
R
e
s
e
r
v
o
i
r
a
n
d
D
e
s
a
l
i
n
i
s
a
t
i
o
n
P
l
a
n
t
7
.
7
h
a
5
.
1
h
a
5
.
0
h
a
5
.
1
h
a
2
.
8
h
a
2
.
8
h
a
O
P
E
N
S
P
A
C
E
4
3
.
2
h
a
L
N
G
3
3
.
1
h
a
6
.
2
h
a
1
6
.
6
h
a
F
l
o
a
t
i
n
g
R
o
a
d
C
L
A
S
S
4
(
3
5
m
)
C
L
A
S
S
2
(
8
0
m
)
C
L
A
S
S
5
(
2
5
m
)
C
L
A
S
S
5
(
2
5
m
)
C
L
A
S
S
5
(
2
5
m
)
C
L
A
S
S
5
(
2
5
m
)
C
C
G
T
4
2
.
8
h
a
C
L
A
S
S
2
(
8
0
m
)
N
M
B
M
7
0
m
1
3
2
K
v
S
e
r
v
i
t
u
d
e
E
s
k
o
m
2
4
0
m
4
0
0
K
v
S
e
r
v
i
t
u
d
e
N
M
B
M
7
0
m
1
3
2
K
v
S
e
r
v
i
t
u
d
e
I
G
a
s
2
0
m
G
a
s
s
e
r
v
i
t
u
d
e
O
P
E
N
S
P
A
C
E
3
2
.
4
h
a
S
e
r
v
i
c
e
s
5
.
6
h
a
7
.
0
h
a
6
.
6
h
a
6
.
2
h
a
6
.
2
h
a
4
.
4
h
a
5
.
0
h
a
3
.
6
h
a
3
.
7
h
a
3
.
7
h
a
5
.
2
h
a
6
.
5
h
a
5
.
3
h
a
9
.
5
h
a
7
.
1
h
a
6
.
5
h
a
O
P
E
N
S
P
A
C
E
5
.
3
h
a
5
.
5
h
a
5
.
3
h
a
5
.
5
h
a
5
.
7
h
a
5
.
5
h
a
4
.
7
h
a
5
.
1
h
a
6
.
5
h
a
5
.
3
h
a
5
.
9
h
a
7
.
7
h
a
1
0
.
1
h
a
7
.
1
h
a
7
.
9
h
a
3
.
2
h
a
3
.
4
h
a
3
.
4
h
a
5
.
4
h
a
2
.
8
h
a
3
.
1
h
a
5
.
5
h
a
5
.
3
h
a
5
.
3
h
a
5
.
3
h
a
5
.
3
h
a
5
.
2
h
a
5
.
5
h
a
3
.
1
h
a
5
.
6
h
a
5
.
2
h
a
5
.
4
h
a
4
.
8
h
a
5
.
4
h
a
5
.
1
h
a
4
.
9
h
a
5
.
3
h
a
5
.
7
h
a
5
.
1
h
a
5
.
1
h
a
5
.
5
h
a
5
.
1
h
a
5
.
8
h
a
5
.
8
h
a
3
.
9
h
a
3
.
2
h
a
5
.
1
h
a
5
.
1
h
a
8
.
8
h
a
4
.
3
h
a
O
P
E
N
S
P
A
C
E
6
.
4
h
a
2
0
.
4
h
a
1
.
1
1
.
2
1
.
3
1
.
4
1
.
5
1
.
6
1
.
7
1
.
8
1
.
9
1
.
1
0
1
.
1
1
1
.
1
2
1
.
1
3
1
.
1
4
1
.
1
5
2
.
1
2
.
2
2
.
3
2
.
4
2
.
5
2
.
6
2
.
1
0
2
.
1
1
2
.
8
2
.
9
2
.
1
2
2
.
7
2
.
1
3
2
.
1
4
2
.
1
5
2
.
1
6
2
.
1
7
2
.
1
8
2
.
1
9
2
.
2
0
2
.
2
1
2
.
2
2
2
.
2
3
2
.
2
4
2
.
2
5
2
.
2
6
2
.
2
7
2
.
2
8
2
.
2
9
2
.
3
0
2
.
3
1
2
.
3
2
2
.
3
3
2
.
3
4
2
.
3
5
2
.
3
6
2
.
3
7
2
.
3
8
2
.
3
9
2
.
4
0
2
.
4
1
2
.
4
2
2
.
4
3
2
.
4
4
2
.
4
5
2
.
4
6
2
.
4
7
2
.
4
8
2
.
4
9
2
.
5
0
2
.
5
1
2
.
5
2
2
.
5
3
2
.
6
2
2
.
6
1
2
.
5
4
2
.
5
5
2
.
6
0
2
.
5
9
2
.
5
6
2
.
5
7
2
.
5
8
P
R
O
P
O
S
E
D
N
M
B
M
7
0
m
1
3
2
K
v
S
e
r
v
i
t
u
d
e
P
R
O
P
O
S
E
D
N
M
B
M
7
0
m
1
3
2
K
v
S
e
r
v
i
t
u
d
e
P
R
O
P
O
S
E
D
N
M
B
M
7
0
m
1
3
2
K
v
S
e
r
v
it
u
d
e
P
R
O
P
O
S
E
D
7
.
5
m
S
e
r
v
i
t
u
d
e
P
R
O
P
O
S
E
D
1
5
m
S
e
r
v
i
t
u
d
e
Z
O
N
E
1
0
B
O
U
N
D
A
R
Y
Z
O
N
E
1
0
B
O
U
N
D
A
R
Y
Z
O
N
E
1
0
B
O
U
N
D
A
R
Y
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
T
E
N
T
O
F
W
O
R
K
S
E
X
I
S
T
I
N
G
T
R
A
F
F
I
C
C
I
R
C
L
E
E
X
I
S
T
I
N
G
R
O
A
D
T
O
N
2
E
X
T
E
N
T
O
F
W
O
R
K
S
I
N
D
I
A
N
O
C
E
A
N
F
S
R
U
L
N
G
C
CO
NT
RO
L C
AB
IN
HY
PO
CH
LO
RIT
E
GE
NE
RA
TIO
N U
NIT
FIR
E P
UM
P R
OO
M
LIQ
UID
LN
G U
NLO
AD
IN
G A
RM
S (x2)
MA
RIN
E H
P U
NL
OA
DIN
G A
RM
S (x4
)
D
A
M
A
R
A
T
E
R
N
CR
YO
GE
NIC
L
NG
P
IP
EL
IN
E
FE
ED
/R
ET
UR
N
GA
S T
RA
NS
MIS
SIO
N P
IP
ELIN
E
FIR
E W
AT
ER
P
IP
IN
G
DOUBLE CIRCUIT 400KV
TRANSMISSION LINES
E
N
G
I
N
E
H
A
L
L
A
1
C
O
M
P
.
R
O
O
M
1
W
A
T
E
R
T
R
E
A
T
M
E
N
T
B
U
IL
D
IN
G
1
L
O
T
A
N
K
Y
A
R
D
1
S
T
E
A
M
T
U
R
B
IN
E
B
U
IL
D
IN
G
1
E
N
G
I
N
E
H
A
L
L
A
2
C
O
M
P
.
R
O
O
M
2
E
N
G
I
N
E
H
A
L
L
A
1
'
C
O
M
P
.
R
O
O
M
1
'
W
A
T
E
R
T
R
E
A
T
M
E
N
T
B
U
IL
D
IN
G
1
'
S
T
E
A
M
T
U
R
B
IN
E
B
U
IL
D
IN
G
1
'
E
N
G
I
N
E
H
A
L
L
A
2
'
C
O
M
P
.
R
O
O
M
2
'
L
O
T
A
N
K
Y
A
R
D
1
'
M
V
R
O
O
M
1
&
C
O
N
T
R
O
L
R
O
O
M
1
L
V
R
O
O
M
F
O
R
C
O
O
L
I
N
G
T
O
W
E
R
C
O
O
L
IN
G
T
O
W
E
R
1
M
V
R
O
O
M
2
M
V
R
O
O
M
1
'
&
C
O
N
T
R
O
L
R
O
O
M
1
'
L
V
R
O
O
M
F
O
R
C
O
O
L
I
N
G
T
O
W
E
R
C
O
O
L
IN
G
T
O
W
E
R
1
'
M
V
R
O
O
M
2
'
S
W
IT
C
H
Y
A
R
D
1
S
W
IT
C
H
Y
A
R
D
1
'
A
S
P
H
A
L
T
R
O
A
D
A
S
P
H
A
L
T
R
O
A
D
A
D
M
IN
/
W
O
R
K
S
H
O
P
P
A
R
K
IN
G
L
O
T
P
A
R
K
IN
G
L
O
T
P
A
R
K
IN
G
L
O
T
E
N
G
I
N
E
H
A
L
L
A
1
C
O
M
P
.
R
O
O
M
1
W
A
T
E
R
T
R
E
A
T
M
E
N
T
B
U
I
L
D
I
N
G
1
L
O
T
A
N
K
Y
A
R
D
1
S
T
E
A
M
T
U
R
B
I
N
E
B
U
I
L
D
I
N
G
1
E
N
G
I
N
E
H
A
L
L
A
2
C
O
M
P
.
R
O
O
M
2
E
N
G
I
N
E
H
A
L
L
A
1
'
C
O
M
P
.
R
O
O
M
1
'
W
A
T
E
R
T
R
E
A
T
M
E
N
T
B
U
I
L
D
I
N
G
1
'
S
T
E
A
M
T
U
R
B
I
N
E
B
U
I
L
D
I
N
G
1
'
E
N
G
I
N
E
H
A
L
L
A
2
'
C
O
M
P
.
R
O
O
M
2
'
L
O
T
A
N
K
Y
A
R
D
1
'
M
V
R
O
O
M
1
&
C
O
N
T
R
O
L
R
O
O
M
1
L
V
R
O
O
M
F
O
R
C
O
O
L
I
N
G
T
O
W
E
R
C
O
O
L
I
N
G
T
O
W
E
R
1
M
V
R
O
O
M
2
M
V
R
O
O
M
1
'
&
C
O
N
T
R
O
L
R
O
O
M
1
'
L
V
R
O
O
M
F
O
R
C
O
O
L
I
N
G
T
O
W
E
R
C
O
O
L
I
N
G
T
O
W
E
R
1
'
M
V
R
O
O
M
2
'
S
W
I
T
C
H
Y
A
R
D
1
S
W
I
T
C
H
Y
A
R
D
1
'
A
S
P
H
A
L
T
R
O
A
D
A
S
P
H
A
L
T
R
O
A
D
A
D
M
I
N
/
W
O
R
K
S
H
O
P
P
A
R
K
I
N
G
L
O
T
P
A
R
K
I
N
G
L
O
T
P
A
R
K
I
N
G
L
O
T
E
N
G
I
N
E
H
A
L
L
A
1
C
O
M
P
.
R
O
O
M
1
W
A
T
E
R
T
R
E
A
T
M
E
N
T
B
U
I
L
D
I
N
G
1
L
O
T
A
N
K
Y
A
R
D
1
S
T
E
A
M
T
U
R
B
I
N
E
B
U
I
L
D
I
N
G
1
E
N
G
I
N
E
H
A
L
L
A
2
C
O
M
P
.
R
O
O
M
2
E
N
G
I
N
E
H
A
L
L
A
1
'
C
O
M
P
.
R
O
O
M
1
'
W
A
T
E
R
T
R
E
A
T
M
E
N
T
B
U
I
L
D
I
N
G
1
'
S
T
E
A
M
T
U
R
B
I
N
E
B
U
I
L
D
I
N
G
1
'
E
N
G
I
N
E
H
A
L
L
A
2
'
C
O
M
P
.
R
O
O
M
2
'
L
O
T
A
N
K
Y
A
R
D
1
'
M
V
R
O
O
M
1
&
C
O
N
T
R
O
L
R
O
O
M
1
L
V
R
O
O
M
F
O
R
C
O
O
L
I
N
G
T
O
W
E
R
C
O
O
L
I
N
G
T
O
W
E
R
1
M
V
R
O
O
M
2
M
V
R
O
O
M
1
'
&
C
O
N
T
R
O
L
R
O
O
M
1
'
L
V
R
O
O
M
F
O
R
C
O
O
L
I
N
G
T
O
W
E
R
C
O
O
L
I
N
G
T
O
W
E
R
1
'
M
V
R
O
O
M
2
'
S
W
I
T
C
H
Y
A
R
D
1
S
W
I
T
C
H
Y
A
R
D
1
'
A
S
P
H
A
L
T
R
O
A
D
A
S
P
H
A
L
T
R
O
A
D
A
D
M
I
N
/
W
O
R
K
S
H
O
P
P
A
R
K
I
N
G
L
O
T
P
A
R
K
I
N
G
L
O
T
P
A
R
K
I
N
G
L
O
T
Z
O
N
E
1
3
L
IM
IT
O
F
C
O
N
S
T
R
U
C
T
IO
N
L
IM
IT
O
F
C
O
N
S
T
R
U
C
T
IO
N
L
IM
IT
O
F
C
O
N
S
T
R
U
C
T
IO
N
PW
99
50.0
50.0
50.0
49.0
4
9
.0
A
C
C
E
S
S
R
O
A
D
S
K
S
W
1
.5
x
1
.2
S
E
R
V
IC
E
C
U
L
V
E
R
T
(S
P
A
R
E
)
Cerebos Service Road Intersection
Alignment=20m Road Reserve, Station=1+14.73
Alignment=35m Road Reserve, Station=1+62.01
49 35BK
49 37
BK
49 38BK
49 35BK
49 34BK
D
E
D
I
S
A
B
O
U
N
D
A
R
Y
L
I
N
E
S
T
O
B
E
C
O
N
F
I
R
M
E
D
E
L
E
C
T
R
I
C
A
L
R
E
S
E
R
V
E
SEE
NOTE: 1
SEE
NOTE: 2
NOTES:
1. EACH 400KV DOUBLE CIRCUIT POWER LINE NEEDS A
SERVITUDE OF 55m
2. THE GAS PIPELINES NEED A 10m SERVITUDE
3. THE 2 x LNG CRYOGENIC PIPELINES NEED A COMBINED
SERVITUDE OF 20m
4. FIREWATER PIPELINE NEEDS 5m SERVITUDE
5. 2 x Ø2.5M COOLING WATER INTAKE PIPES
6. 2 x Ø2.5M COOLING WATER OUTFALL PIPES
7. COOLING WATER OUTFALL OPTION OF STAND ALONE
RACEWAY 400M LONG x 20M WIDE
8. ZONE 13 ASSUMED AIR COOLED POWER PLANT
9. ZONE 10S ASSUMED WET MECHANICAL DRAFT COOLING
POWER PLANT
10. ZONE 10N ASSUMED ONCE THROUGH SEA WATER COOLED
POWER PLANT
11. COOLING WATER OUTFALL OPTION OF A RACEWAY
CONNECTED TO THE EXISTING BREAKWATER
12. COOLING WATER OUTFALL OPTION VIA A TUNNEL
MAXIMUM FOOT PRINT ALLOWED FOR EACH POWER PLANT -
18.1ha each
MAXIMUM FOOT PRINT ALLOWED FOR LNG GAS HUB IS 23.1ha.
WHEN PIPELINES ARE LOCATED IN A SERVITUDE WITH HV
POWER LINES, THE PIPELINE CAN INCUR INDUCED VOLTAGES
AND CURRENTS DUE THE AC INTERFERENCE, THESE
INTERFERENCE AND INDUCED VOLTAGE ISSUES ARE WELL
UNDERSTOOD.
TO PROTECT BURIED PIPELINES AGAINST CORROSION AND
INDUCED VOLTAGES, SUITABLE PIPING PROTECTION MEASURES
MUST BE INCLUDED DURING DETAILED DESIGN, CONSTRUCTION
AND OPERATIONS, INCLUDING SUITABLE CATHODIC
PROTECTION.”
09-05-2020
SEE
NOTE: 3
SEE
NOTE: 4
SEE
NOTE: 5
SEE
NOTE: 6
SEE
NOTE: 7
Z
O
N
E
1
0
N
Z
O
N
E
1
0
S
SEAWATER RETURN FOR LNG REGASSIFICATION
(INDICATIVE ONLY)
(INTAKE VIA SEAWATER COOLING FOR POWER PLANTS OR
AQUA CULTURE)
5
5
m
SIGNIFICANT
INTERSECTION
SEE
NOTE: 11
SEE
NOTE: 12
SCALE
200 m
1000 m
001-P
OW
ER
P
LA
NT
S - 20200512-01-G
A
28/06/2020
TRUCK LOADING AND UTILITIES
GAS DISTRIBUTION FACILITY
ADMIN /WORKSHOP
LAYDOWN AREA/PARKING LOT
SWIT
CH
YAR
D 1
SWIT
CH
YAR
D 1
'
ASPHALT ROAD
ASPHALT ROAD
MV ROOM 2'
COOLINGTOWER 1'
MV ROOM 1' & CONTROL ROOM 1'MV ROOM 2
COOLINGTOWER 1
LV R
OO
MFO
RC
OO
LIN
GTO
WER
LO TANKYARD 1'
CO
MP.
RO
OM
2'
ENG
INE
HAL
L A2
'
STEAMTURBINEBUILDING
1'
WATERTREATMENT
BUILDING1'
CO
MP.
RO
OM
1'
ENG
INE
HAL
L A1
'
CO
MP.
RO
OM
2
ENG
INE
HAL
L A2
STEAMTURBINEBUILDING
1
LO TANKYARD 1
WATERTREATMENT
BUILDING1
CO
MP.
RO
OM
1
MV ROOM 1 & CONTROL ROOM 1
ENG
INE
HAL
L A1
LV R
OO
MFO
RC
OO
LIN
GTO
WER
LAYDOWN AREA/PARKING LOT
LAYDOWN AREA/PARKING LOT
CC
CC
CC
CC
FAC
ILIT
Y M
ETER
S
SYST
EM M
ETER
S
1m G
ATE
**
5M S
LID
ING
GAT
E
5M S
LID
ING
GAT
E
WR
BW
RB
WCRELAY ROOM STORE ROOM
INDUCTION ANDSCREENING BUILDING
54
WEATHER STATION
BOG VENT
BACK-UP WEATHER STATION
STEAM TURBINE PACKAGE
17
18
55
19
20
MOTORS BUILDING
OXIDATION CATALYST
56
RUPTURE DISC
57
EXHAUST GAS SILENCER
FEED WATER PUMPS
OILY WATER COLLECTING PIT
COMPRESSORS
STATION TRANSFORMER
CONTROL PIT
RADIATOR NL1 (61dB)
FIRE WATER TANKS
58 WATER TREATMENT
FIRE PUMP STATION
WATER TREATMENT CONTAINER
SLUDGE TANK
SERVICE / USED LUBE OIL TANK
59
CLEAN LUBE OIL TANK
L.O. UNLOADING PUMP UNIT (CLEAN)
L.O. TRANSFER PUMP UNIT
SLUDGE LOADING PUMP UNIT
60
ADMINISTRATION, SHOP & WAREHOUSE
WORKSHOP BUILDING
WAREHOUSE BUILDING
27
61
GT FIN FAN COOLERS
53
62
54
01
02
DEMINERALISED WATER TANK
45
03
04
05
46
06
07
08
09
10
63
11
12
14
13
15
16
21
05
22
64
RAW WATER TANK
2424
23
07
ACCESS DOORTO CONTROL ROOM
ACCESS DOORTO LV SWITCHGEAR ROOM 2
ACCESS DOORTO MV ROOM
TOILETTOILET
STORAGE MEETING ROOMGenerating Set Control Panel
CFC131
CFC121
CFC111
CFC101
CFC091
CFA901
CFA901
CFA901
CFA901
CFA901
24
CFC081
CFC071
CFC061
CFC051
CFC041
CFC031
CFC021
CFC011
LIGHTINGPANEL
(WALL MOUNTED)
MV ROOM LIGHTINGPANEL
(WALL MOUNTED)
ACCESS DOORTO CABLE GALERY
GAS DETECTIONPANEL
2 set WOIS2 Set WISE
LIGHTINGPANEL
1 set WOIS
25
1 Set WISE(WALL MOUNTED) 2 Set ENGINERING STATION
FM200 BOTTLEØ500mm
2 set WOIS2 Set WISE
CONTROL ROOMCommon Control Panel
ACCESS DOORTO CABLE GALERY LV SWITCHGEAR ROOM 2
Generating Set Control Panel
BATTERY ROOM UAT5ENG13
ACCESS DOORTO CABLE GALERY
GROUP 3 BLOCK 2 GROUP 3 BLOCK 1 GROUP 2 BLOCK 2 GROUP 2 BLOCK 1 GROUP 1
GT3/2 ENG12ENG11BBVT5 BBVT4UAT4 GT3/1ENG10ENG9 BBVT3UAT3 GT2/2 ENG8ENG7ENG6 BBVT2UAT2 GT2/1 ENG5 ENG4 BBVT1UAT1 GT1 ENG3 ENG2ENG1
LV SWITCHGEAR ROOM 1ACCESS DOOR
TO CABLE GALERY
FM200
LIGHTINGPANEL
(WALL MOUNTED)
01
26
05
05
10
04
03
11
08
1206
020504
03
13
14
15
02
161718
3839
40
41
42
44
43
30
29
35
3736
28
3433
09
32
31
28
26
27
2021
19
25
30
29
23
CC
TV F
IRE
ALAR
M
B4
ADMINISTRATION BUILDING
CONTROL & ELECTRICAL BUILDING
GATE HOUSE
65
STEP-UP TRANSFORMER
UNLOADING GATE HOUSE
TRUCK UNLOADING BAY 1
TRUCK UNLOADING BAY 2
47
TRUCK WAITING AREA
TRUCK UNLOADING BAY 3
29
30
31
NITROGEN STORAGE TANK
66
NEUTRALISED WATER TANK
ST FIN FAN COOLERS
32
33
34
TRU
CK
WEI
GH
BR
IDG
E
47
48
35
48
49
GEN
ERAT
OR
PARKING
36
GAS METERING AND PRESSURE REDUCTION
22
37
ACCESS DOORTO LV SWITCHGEAR ROOM 1
38
39
50
DIESEL STORAGE
67
51
40
41
42
52
43
49
VISI
TOR
S AN
D C
ON
TRAC
TOR
S PA
RKI
NG
IND
UC
TIO
N A
ND
SC
REE
NIN
G
44
45
STAFF PARKIN
G
46
LNG DRAINAGE CHANNEL
DIESEL UNLOADING PUMP
68
LNG DRAINAGE PIT
LNG TRANSFER PUMPS AREA
BOG COMPRESSOR
LNG VESSEL 1000 m3 1
50
LNG VESSEL 1000 m3 2
LNG VESSEL 1000 m3 3
LNG VESSEL 250 m3 1
LNG VESSEL 250 m3 2
NITROGEN VAPORIZER
GAS TURBINE PACKAGE
LNG MAIN PUMPS AREA
LNG VAP-1 A/B
LNG VAP-2 A/B
LNG VAP-3 A/B
51
LNG VAP-4 A/BMETERING SYS & PRESSURE
52
REDUCTION
53 CHANGE HOUSE
LNG AUX. VAP
DIESEL GENERATOR
HEAT RECOVERY STEAM GENERATOR
AIR COOLED CONDENSOR
Zone 13 Phase 1
Zone 13 Phase 2
ITEM DESCRIPTION
45.90
56.7
5
63.99
ITEM DESCRIPTION
ZONE 13 PHASE 1 LEGEND
60.0
0
15.00
2.00
2.01
15.3
8
60.00
60.0
0