1
اداره طرح و مهندسی مراکز
NGN Network Architecture
2
اداره طرح و مهندسی مراکز NGN Network Architecture
Edge Access
Core Switch
Network Control
Service Management
3
اداره طرح و مهندسی مراکز NGN Network Architecture
IAD AMGBroadBand
Access
UMG
PLMN/3G
SG TMG
PSTN
UMG
Service Management
Packet Core Network
Network Control
Core Switching
Edge Access
SoftSwitch SoftSwitch
iOSS PolicyServer
ApplicationServer
SCPLocationServer
RADIUSServer
MRS
4
اداره طرح و مهندسی مراکز
Huawei U-SYS Network ArchitectureHuawei U-SYS Network Architecture
Service Layer
Control Layer
Core Switch Layer
Access Layer
SoftX3000SoftX3000
3G AccessAMG5000IAD 2000 seriesBroadband
Access PSTNPSTN TMG8010SG7000
PLMNPLMN
SoftX3000SoftX3000
IP Core Video GW
UMG8900
UMG8900
SIP/H.323Phone
U-Path
UU--NICANICAApp ServerApp Server
RM9000RM9000 MRS 6000/ 6100MRS 6000/ 6100ININ
TopEngTopEngOSSOSS
iManageriManagerN2000N2000 UcUc serverserver
PSTN
switchSTP
Open Eye 2GTerminal 3G
Terminal
5
اداره طرح و مهندسی مراکز
UU--NICA App ServerNICA App Server IN Application ServerIN Application ServerRM9000RM9000 Resource ManagerResource ManagerMRS6000/6100MRS6000/6100 Media Resource ServerMedia Resource ServerUCUC Unified CommunicationUnified CommunicationiManageriManager N2000 Integrated NMSN2000 Integrated NMSSoftX3000SoftX3000 SoftSwitchSoftSwitchSG7000 SG7000 SignallingSignalling MGMGUMG8900 UMG8900 Universal MGUniversal MGAMG5000 AMG5000 Access MGAccess MG
IAD2000 IAD2000 sserieseries Integrated Access DeviceIntegrated Access DeviceUU--PathPathOpeneyeOpeneye、、video terminalvideo terminal
U-SYS key productsU-SYS key products
6
اداره طرح و مهندسی مراکز Huawei U-SYS Products
Service LayerUCMRS6000MRS6100RM9000iManagerN2000UMSIADMSIAD Hatcher
Control LayerSoftX3000
Core Switch LayerEudemon2100/2200NE40/NE80
Access LayerUMG8900VIG8920AMG5000UA5000IADSG7000Hard PhoneSoft Phone: OpenEyeUPATH
Huawei provide entire NGN network solution.
7
اداره طرح و مهندسی مراکز
HuaWei U-SYS Products
Service LayerUCMRS6000MRS6100RM9000iManagerN2000UMSIADMSIAD Hatcher
Control LayerSoftX3000
Core Switch LayerEudemon2100/2200NE40/NE80
Access LayerUMG8900VIG8920AMG5000UA5000IADSG7000Hard PhoneSoft Phone: OpenEyeUPATH
We just introduce partial important elements.
8
اداره طرح و مهندسی مراکز
Contents
Chapter 1 U-SYS System Structure
Chapter 2 Service and Control Layer
Chapter 3 Access and Core Switch Layer
Chapter 4 other components
9
اداره طرح و مهندسی مراکز
Service and Control Layer
Service LayerUCMRS6000MRS6100RM9000iManagerN2000UMSIADMSIAD Hatcher
Control LayerSoftX3000
Core Switch LayerEudemon2100/2200NE40/NE80
Access LayerUMG8900VIG8920AMG5000UA5000IADSG7000Hard PhoneSoft Phone: OpenEyeUPATH
10
اداره طرح و مهندسی مراکز
SoftX3000 brief introduction
SoftX3000 is applicable to the network control layer of NGN and implements call control and connection management of voice, data and multimedia services based on the IP network.
SoftX3000 supports the traditional PSTN signaling, such as SS7, R2, DSS1 and V5. can be a voice end office, tandem office or toll office.
SoftX3000 supports black and white lists, call authentication, call interception, and so on.
SoftX3000 supports MTP and M3UA, can be an integrated signaling gateway.
SoftX3000 supports INAP and INAP+, so it can be used as an SSP or IPSSP in the IN system.
SoftX3000 supports the H.323 protocol and can function as a gatekeeper (GK) in the traditional Voice over IP (VoIP) network.
11
اداره طرح و مهندسی مراکز
System capacityItem Specification
Maximum number of supported TDM trunks 360,000Maximum number of supported gateways 2,000,000Maximum capacity of supported black and white lists 1,000,000
Maximum capacity of supported external prepaid card numbers 1,000,000
POTS subscribers: 2,000,000V5 subscribers: 2,000,000IPN subscribers: 200,000IP consoles: 100,000SIP terminals: 2,000,000
Maximum number of supported multimedia terminals H.323 terminals:
1,000,000
Maximum number of supported subscribers
12
اداره طرح و مهندسی مراکز
System processing capability
Item Specification
BHCA of a single service processing module 400k
BHCA of the system 16000k
Call drop rate ≤ 0.01%
Calls between intra-domain subscribers: < 200 ms
Call setup timeCalls between both intra-domain subscribers and out-domain subscribers: < 500 ms
13
اداره طرح و مهندسی مراکز
Access and Core Switch Layer
Service LayerUCMRS6000MRS6100RM9000iManagerN2000UMSIADMSIAD Hatcher
Control LayerSoftX3000
Core Switch LayerEudemon2100/2200NE40/NE80
Access LayerUMG8900VIG8920AMG5000UA5000IADSG7000Hard PhoneSoft Phone: OpenEyeUPATH
14
اداره طرح و مهندسی مراکز
AMG5000
AMG5000 Brief Introduction AMG5000
network application AMG5000
hardware (frame and board)
AMG5000 system
capacity
15
اداره طرح و مهندسی مراکز
AMG5000 Brief Introduction AMG :(Access Media Gateway)• It belongs to the media access layer, which converts
messages formats to those that can be transmitted through the IP network.
• It is oriented to telecom carriers and Intranet users.
Relevant equipment classification standard and application environment:
Class Application location POT Sport scale
AMG5000 C5 end office, building, and equipment
room of the community
Corridor or desktopIAD
Above 32 ports
1-32 ports
16
اداره طرح و مهندسی مراکز
AMG5000 in NGN Access Layer
PSTN
H.323GK
MRS
3rd Party Server
SoftSwitch
R
SoftSwitch
TMG
IAD
Ephone
PCphone
SIP multime
dia terminal
IP networkMGCP/H.248
AMG5000
MGCP/H.248
R
AAA SCP
MRS
IP network
Access Layer
17
اداره طرح و مهندسی مراکز
AMG5320 Cabinet
(1) Power indicator
(2) Environment monitoring indicator
(3) Reserved
(4) Power distribution frame
(5) Dummy panel
(6) Fan shelf
(7) Subscriber frame
(8) Cabling trough
(9) Dummy panel
(10) Dummy panel
(11) Storage battery
(12) Battery shelf
(1) Power indicator
(2) Environment monitoring indicator
(3) Reserved
(4) Power distribution frame
(5) Dummy panel
(6) Fan shelf
(7) Subscriber frame
(8) Cabling trough
(9) Dummy panel
(10) Dummy panel
(11) Storage battery
(12) Battery shelf
•The F01 cabinet is used in AMG5320, which inherits the previous product in such respects as the F01 cabinet, power and monitoring component, battery, subscriber line board and test board.
18
اداره طرح و مهندسی مراکز
Hardware System-Bus Structure
After being accessed via ASL, the voice signals of the subscriber will be converted to the VoIP package via PVM. Then, the signal will be connected with the router via the LSW chip network interface of PVM and transmitted to the upstream IP network.
Voice packet processing
module´
AMG5320 FE
Data busControl bus
Test busSubscriber external line
PVM
TSS
ASL
ASL
ASL
PVM
...
to IP network
PWX
P
XW
19
اداره طرح و مهندسی مراکز
UMG8900(next week)
UMG8900 Brief Introduction UMG8900
network application UMG8900
hardware (frame and board)
UMG8900 system
capacity
20
اداره طرح و مهندسی مراکز
SG7000
SG7000 Brief Introduction
SG7000 network application
SG7000 hardware (frame and board)
SG7000 system
capacity
21
اداره طرح و مهندسی مراکز
SG7000 Brief Introduction
SG: Signalling Gateway,used in the access layer in NGN
Connected to narrowband PSTN network with standard No. 7 signaling protocol
Connected to NGN equipment with packet network interface and standard SIGTRAN protocol to implement the IP bearer of No. 7 signaling
22
اداره طرح و مهندسی مراکز
Networking DiagramNetworking diagram in signaling transition point mode
LS
STP
SS7
SS7
LS
SoftX1
SoftX2
SG2
SG1
Point Code 1Point Code 2
Point Code 3
M2PA/M3UA
M2PA/M3UA
M2PA/M3UA
SG7000 networking in signaling transition point mode
Independent with softswitch
23
اداره طرح و مهندسی مراکز
Location of SG7000 in Independent Gateway Model
SG7000 in separate gateway model
SS7
Circuit
SS7
Circuit
PSTN
PSTN
IP networkSG SG
MG MGMGC MGC
SIGTRAN SIGTRAN
24
اداره طرح و مهندسی مراکز
Main Control Cabinet in Full Configuration
B68-21 cabinet in full configuration
The SG7000 uses IEC-standard B68-21 cabinet, with dimensions 2100 mm × 600 mm × 800 mm (H × W × D).
At most support 16 frames
DC distributor box
2U
14U
14U
2U
LAN Switch 1LAN Switch cabling frame
2U
2U
1U1U
BAM server
Service shelf
Service shelf
LAN Switch cabling frameLAN Switch 0
LCD display switcher
Dummy panel
Dummy panel
1U1U
1U1U
25
اداره طرح و مهندسی مراکز
Relationship of SG7000 Boards
TDM interface
IP interface
CKII
VIEB
HSYSHBIU
PSTN
HCOMSCBUcascading
EPII
WS oriManager N2000
SoftX3000
M2PA/M3UA
8k/2MClock
IP
CCS7 64k/2M
MML/SNMP
1*100M Ethernet
HSCU
SBPU8 E1/T1
ALUI
SBPI
Front boardBack board
10M/100M Ethernet
Lan Switch10M/100M Ethernet
Pinch board is SLPU
16 *Slave frame
BAM
Lan Switch
BUS
M2PA/M3UA
26
اداره طرح و مهندسی مراکز
Service Processing Subsystem
HW
IP interface(FE)
High-speed bus
IP interface unit
(VIEB)
ÒµÎñ´¦Àíµ¥
Local high-speed bus
E1/T1 interface
Equipment management unit
(HSYS)
Signaling interface module
Signaling bottom processing module
Service processing modulePSTN,PLMNNo.7 signaling network
Narrowband signaling processing unit
(SLPU)
Narrowband E1/T1 interface unit
EPII
System support moduleClock unit
(CKII)
ÒµÎñ´¦Àíµ¥
Broadband signaling processing unit
(SBPU)
External clock source
TDM switching bus
LAN drive and IP distribution unit
(SBPI)Soft switch equipmentFE
27
اداره طرح و مهندسی مراکز
System Capacity
Modules are smoothly expanded to increase signaling links.
Each SBPU can process 32*64K signaling links or can process
2*2M high-speed signaling links
Supporting up to 5120 *64 kbit/s signaling links
Supporting up to 640 * 2 Mbit/s high-speed signaling links
28
اداره طرح و مهندسی مراکز
IAD2000 series
IAD2000 Brief Introduction IAD2000
network application
IAD2000 hardware
IAD2000 capacity
29
اداره طرح و مهندسی مراکز
IAD2000IAD: Integrated Access Device
HuaWei IAD Type:IAD101EIAD102EIAD104EIAD108EIAD208EIAD116EIAD132E(T)
30
اداره طرح و مهندسی مراکز
IAD2000 in NGN NetworkSoftSwitch
Telephone line
IP Network
iOSS
App server
IAD132E(T)
IAD132E(T)
LSW
LSW
Telephone line
TelephoneHybrid category 5
Category 5
Category 5
NGN iManager
IADMS
Category 5
splitter
DVC
Hybrid category 5
31
اداره طرح و مهندسی مراکز
IAD2000
IAD101/102E
PWR: Local power port WAN:uplink port LAN:data user port PHONE1/2:POTS ports LINE:Local PSTN POTS port
32
اداره طرح و مهندسی مراکز
IAD104E
PWR VOIP Ethernet Phone
10/ 100M Link/ ActWAN
10/LAN
100M Link/ Act1 2 3 4
PWR
Front side
rear side
33
اداره طرح و مهندسی مراکز
IAD108E
(1):Local power port (2):uplink port (3)、(4):data user port (5)~(12):POTS ports (13):Local maintenance serial port
WAN
34
اداره طرح و مهندسی مراکز
IAD208E
(1):Local power port (2):uplink port (3)~(10) 8 User ports, thereinto (3)~(9) are hybrid port(support 10M network cable and POTS),(10) is only POTS port (11) Local maintenance serial port
splitterCategory 5 cable
Category 5 cable
Telephone lineCrossover Category 5 cable
LAN SWITCH
WAN
35
اداره طرح و مهندسی مراکز
IAD116E
Front side
rear side
VOIP card (8 port)
36
اداره طرح و مهندسی مراکز
IAD132E(T)IAD132E(T): two types
1:Front cable box
2:Rear and Front cable box
37
اداره طرح و مهندسی مراکز
IAD132E(T)
1 2 3 4
21 3 4 5 6
Front side
rear side