HP BladeSystem Networking Reference
Architecture
HP Virtual Connect FlexFabric Module and VMware vSphere 5
Technical white paper
Table of contents
Executive Summary .............................................................................................................................. 2
Virtual Connect FlexFabric Module Hardware Overview .......................................................................... 3
Designing an HP FlexFabric Architecture for VMware vSphere .................................................................. 4
Designing a vSphere Network Architecture with the Virtual Connect FlexFabric module ............................... 7
vNetwork Distributed Switch Design ................................................................................................... 7
Network I/O Control ........................................................................................................................ 9
Hypervisor Load Balancing Algorithms ............................................................................................... 9
Modifying Server Profiles with Online Servers .................................................................................... 10
HP NC551 and NC553 Minimum Supported Firmware and Drivers .................................................... 10
Appendix A: Virtual Connect Bill of Materials ....................................................................................... 11
Appendix B: Terminology cross-reference ............................................................................................. 11
Appendix C: Glossary of Terms ........................................................................................................... 12
For more information .......................................................................................................................... 14
2
Executive Summary
HP has revolutionized the way IT thinks about networking and server management. With the release
of the HP ProLiant BladeSystem Generation 6 servers, along with Virtual Connect Flex-10 Ethernet
modules, HP provided a great platform for VMware vSphere. Virtual Connect Flex-10 is the world's
first technology to divide and fine-tune 10Gb Ethernet network bandwidth at the server edge. When
combined with Virtual Connect, the BladeSystem architecture streamlines the typical change processes
for provisioning in the datacenter.
HP has since evolved Virtual Connect Flex-10 to the next level: Virtual Connect FlexFabric modules.
By combining the power of ProLiant BladeSystem Generation 7 servers and Virtual Connect, the
Virtual Connect FlexFabric module allows customers to consolidate network connections and storage
fabrics into a single module. This further reduces infrastructure cost and complexity by eliminating
HBA adapters and Fibre Channel modules at the edge.
These servers include virtualization friendly features such as larger memory capacity, dense
population, room for additional mezzanine cards and 4 - 64 (with Intel Hyper-Threading technology
enabled and AMD Opteron 6200-series) processing cores. The following ProLiant BL Servers ship
standard with the NC551i FlexFabric Adapter:
BL465 G7
BL685 G7
The following ProLiant BL Servers ship with the NC553i FlexFabric Adapter:
BL460 G7
BL490 G7
BL620/680 G7
Additionally, the NC551m and NC553m provide support for the FlexFabric Adapter in ProLiant
BladeSystem G6 servers.
NOTE: Please check the latest NC551m1 and NC553m2 QuickSpecs for the official server
support matrix.
The ProLiant Generation 8 servers do not ship with a built-in adapter. Instead, HP offers a FlexLOM
option to where customers can chose which FlexFabric Adapter vendor they want. Please review the
server models QuickSpecs for support FlexLOM adapters.
The FlexFabric Adapter introduces a new Physical Function called the FlexHBA. The FlexHBA, along
with the FlexNIC, adds the unique ability to fine-tune each connection to adapt to your virtual server
channels and workloads on-the-fly. The effect of using the Virtual Connect FlexFabric module is a
reduction in the number of interconnect modules required to uplink outside of the enclosure, while still
maintaining full redundancy across the service console, VMkernel, virtual machine (VM) networks and
1 http://h18004.www1.hp.com/products/blades/components/emulex/nc551m/index.html
2 http://h18004.www1.hp.com/products/blades/components/emulex/nc553m/index.html
3
storage fabrics. This translates to a lower cost infrastructure with fewer management points, switch
modules, adapter cards and cables.
This whitepaper will focus on designing a highly available network and vSphere Cluster architecture
by providing redundant uplinks across physical modules, but also across enclosures. This design will
also maximize the management features of Virtual Connect, while providing customers with the
flexibility to provide “any networking to any host” within the Virtual Connect domain. Simply put, this
design will not over-provision servers, while keeping the number of uplinks used to a minimum. This
helps reduce infrastructure cost and complexity by trunking the necessary VLANs (IP Subnets) to the
Virtual Connect domain, and minimizing potentially expensive 10Gb uplink ports.
Finally, this document will provide key design best practices for vSphere 5 network architecture with
HP FlexFabric, including:
vDS design for Hypervisor networking
vSwitch and dvPortGroup load balance algorithms
Virtual Connect FlexFabric Module Hardware Overview
The Virtual Connect FlexFabric module is the first Data Center Bridging (DCB) and Fibre Channel over
Ethernet (FCoE) solution introduced into the HP BladeSystem portfolio. It provides 24 line rate ports,
Full-Duplex 240Gbps bridging, single DCB-hop fabric. As shown in Image 1, there are 8 faceplate
ports. Ports X1-X4 are SFP+ transceiver slots only; which can accept a 10Gb or 8Gb SFP+
transceiver. Ports X5-X8 are SFP and SFP+ capable, and do not support 8Gb SFP+ transceivers.
NOTE: The CX-4 port provided by the Virtual Connect Flex-10 and legacy modules has been
depreciated.
Image 1: HP Virtual Connect FlexFabric Module
Ports X7 and X8 are shared with internal Stacking Link ports. If the external port is populated with a
transceiver, the internal Stacking Link is disabled. At least one Stacking Link is required between
modules. Please refer to the Virtual Connect User Guide or Multi-Enclosure Stacking Reference
Guide3 for more information.
3 http://bizsupport2.austin.hp.com/bc/docs/support/SupportManual/c02102153/c02102153.pdf
4
Important: Even though the Virtual Connect FlexFabric module supports Stacking, stacking
only applies to Ethernet traffic. FC uplinks cannot be consolidated, as it is not possible to
stack the FC ports, nor provide a multi-hop DCB bridging fabric today.
Designing an HP FlexFabric Architecture for VMware
vSphere
In this design, two HP ProLiant c-Class 7000 Enclosures with Virtual Connect FlexFabric modules are
stacked to form a single Virtual Connect management domain4. By stacking Virtual Connect
FlexFabric modules, customer can realize the following benefits:
Management control plane consolidated
More efficient use of WWID, MAC and Serial Number Pools
Provide greater uplink port flexibility and bandwidth
Profile management across stacked enclosures
Shared Uplink Sets provide administrators the ability to distribute VLANs into discrete and defined
Ethernet Networks (vNet.) These vNets can then be mapped logically to a Server Profile Network
Connection allowing only the required VLANs to be associated with the specific server NIC port. This
also allows customers the flexibility to have various network connections for different physical
Operating System instances (i.e. VMware ESX host and physical Windows host.)
As of Virtual Connect Firmware 3.305 release, the following Shared Uplink Set rules apply per
domain:
1000 Unique VLANs (Ethernet Networks) per Virtual Connect Domain
162 Unique Server Mapped VLANs per Server Profile Network Connection
Important: When using FlexNICs, the 162 Unique Server Mapped VLAN maximum is an
aggregate of all FlexNICs that belong to the same 10Gb Physical Interface. A FlexHBA also
counts as a single VNET against the 162 total.
By providing two stacked Enclosures, this will allow for not only Virtual Connect FlexFabric module
failure, but also Enclosure failure. The uplink ports assigned to each Shared Uplink Set (SUS) were
vertically offset to allow for horizontal redundancy purposes, as shown in Figure 1-2.
IP-based storage (NFS and/or iSCSI) can be dedicated and segregated by a separate vNet and
assigned uplink port. This design approach provides administrators to dedicate a network (physically
switched, directly connected or logical within a Shared Uplink Set) to provide access to IP-based
storage arrays.
4 Only available with Virtual Connect Manager Firmware 2.10 or greater. Please review the Virtual Connect Manager Release Notes for more
information regarding domain stacking requirements: http://h18004.www1.hp.com/products/blades/components/c-class-tech-installing.html
5 Only when the Expanded VLAN Capacity feature is enabled in the Domain (Ethernet -> Advanced Settings)
5
Directly connecting an IP-based Storage array has certain limitations:
Each storage array front-end port will require a unique vNet
Each defined vNet will require separate server network connections
You are limited to the number of IP-based arrays based on the number of unassigned uplink
ports
Note: Please review the Virtual Connect with iSCSI Cookbook Third Edition or newer6 for
more information on how to directly attach an IP-based storage device to Virtual Connect.
Virtual Connect has the capability to create an internal, private network without uplink ports, by using
the low latency mid-plane connections to facilitate communication. This vNet can be used for cluster
heartbeat networks, or in this case VMotion and/or Fault Tolerance traffic. Traffic will not pass to the
upstream switch infrastructure, which will eliminate the bandwidth otherwise consumed.
Figure 1-1: Physical VMware vSphere Cluster Design
Figure 1-2 show the physical cabling. The X5 and X6 Ethernet ports of the FlexFabric module are
connecting to a redundant pair of Top of Rack (ToR) switches, using LACP (802.3AD) for link
redundancy. The ToR switches can be placed End of Row to save on infrastructure cost. Ports X7 are
used for vertical External Stacking Links, while X8 are used for Internal Stacking Links.
6 http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02533991/c02533991.pdf
6
As noted in the previous section, Virtual Connect FlexFabric Stacking Links will only carry Ethernet
traffic, and do not provide any Fibre Channel stacking options. Thus, ports X1 and X2 from each
module are populated with 8Gb SFP+ transceivers, providing 16Gb net FC bandwidth for storage
access. Ports X3 and X4 are available to provide additional bandwidth if FC storage traffic is
necessary.
If additional Ethernet bandwidth is necessary, ports Enc0:Bay2:X5, Enc0:Bay2:X6, Enc1:Bay1:X5,
and Enc1:Bay1:X6 can be used for additional Ethernet Networks or Shared Uplink Sets.
Figure 1-2: Physical cabling design
7
Figure 1-3: Logical design
Designing a vSphere Network Architecture with the Virtual
Connect FlexFabric module
The vNetwork Distributed Switch7 (vDS) allows an administrator to create a centralized distributed
vSwitch, which share a common networking configuration across hosts. Port Groups are still utilized in
this model, but have a different association to host uplink ports. Host uplink ports are added to Uplink
Groups (dvUplinkGroup), where a logical association between the dvUplinkGroup and a PortGroup
(dvPortGroup) is formed. vDS can service any of the vmkernel functions; Service Console, VMotion, IP
Storage, and Virtual Machine traffic.
In this section, we will outline the overall vDS design.
vNetwork Distributed Switch Design
Each pair of redundant pNICs will be assigned to dvUplinkGroups, which then are assigned to a
specific vDS. This will simplify host network configuration, while providing all of the benefits of a
vDS. Table 2-1 and Figure 2-1 shows which hypervisor networking function will be assigned to vDS
configuration.
Table 2-1 VMware vDS Configuration Example
VMkernel Function vDS Name dvPortGroup Name
ESXi Host Management dvs1_mgmt dvPortGroup1_Mgmt
VMotion dvs2_vmkernel dvPortGroup2_vmkernel
VM Networking1 dvs3_vmnet dvPortGroup3_vmnet100
7 Requires vSphere 5.0 Enterprise Plus licensing; Please refer to the vSphere 5 Maximums document on supported configuration maximums -
http://www.vmware.com/pdf/vsphere5/r50/vsphere-50-configuration-maximums.pdf
8
Table 2-1 VMware vDS Configuration Example
VMkernel Function vDS Name dvPortGroup Name
VM NetworkingN dvs3_vmnet dvPortGroupN_vmnetNNN
Figure 2-1: Hypervisor Networking Design
Important: Please know that for HP CloudSystem Matrix installations, the dvPortGroup for
the Service Console must be named “Management Network.”
Mixing vSphere Standard Switches and vSphere Distributed Switches is possible. The current
scalability limits to the vDS may require some designs to incorporate both. HP would recommend
vmkernel functions (vMotion, Management, IP Storage, FT) be assigned to Standard vSwitches, and
use vDS for Virtual Machine networking.
VMware Fault Tolerance (FT) could introduce more complexity in to the overall design. VMware
states that a single 1Gb NIC should be dedicated for FT logging, which would have the potential to
starve any shared pNIC with that of another vmkernel function (i.e. VMotion traffic.) FT has not been
taken into consideration within this document. Even though FT could be shared with another vmkernel
9
function, and if FT is a design requirement, then the overall impact of its inclusion should be
examined.
With the design example given, there are three options one could choose to incorporate FT Logging:
Table 2-2 VMware Fault Tolerance Options
FT Design Choice Justification Rating
Share with VMotion
network
The design choice to keep VMotion traffic internally to the Domain
allows the use of low latency links for inter-Domain communication.
NetIOC could be used to control and provide VMotion or FT traffic
higher shares, or priority, over the other traffic.
***
Non-redundant VMotion
and FT networks
Dedicate one pNIC for VMotion traffic, and the other for FT
logging traffic. Neither network will provide pNIC redundancy.
**
Add additional
FlexFabric Adapters
and Modules
This option increases the overall CapEx to the solution, but will
provide more bandwidth options.
*
Network I/O Control
Network I/O Control8 (NetIOC), is a feature of the vDS that provides QoS-like capabilities. NetIOC
can identify the following types of traffic:
Virtual Machine
FT Logging
iSCSI (Software Initiator only; HW iSCSI Offload not supported)
NFS
Service Console Management
vMotion
NetIOC can be used to control identified traffic, when multiple types of traffic are sharing the same
pNIC. In our design example above, FT Logging could share the same vDS as the vmkernel, and
NetIOC would be used to control the two types of traffic. NetIOC can also be used to apply an
802.1p tag for DataCenter QOS, which is not supported by Virtual Connect at this time.
Hypervisor Load Balancing Algorithms
VMware provides a number of different NIC teaming algorithms, which are outlined in Table 2-3. As
the table shows, any of the available algorithms can be used, except IP Hash. IP Hash requires
switch assisted load balancing (802.3ad), which Virtual Connect does not support 802.3ad with
server downlink ports. HP and VMware recommend using Originating Virtual Port ID with Standard
vSwitch, and Phycial NIC Load when using vDS and NetIOC, as shown in Table 2-3.
8 http://www.vmware.com/files/pdf/techpaper/VMW_Netioc_BestPractices.pdf (vSphere 4.1) or Managing Network Resources chapter in
http://pubs.vmware.com/vsphere-50/topic/com.vmware.ICbase/PDF/vsphere-esxi-vcenter-server-501-networking-guide.pdf
10
Table 2-3 VMware Load Balancing Algorithms
Name Algorithm Works with VC
Originating Virtual Port
ID
Choose an uplink based on the virtual port where the
traffic entered the virtual switch.
Yes
Source MAC Address MAC Address seen on vnic port Yes
IP Hash Hash of Source and Destination IP’s. Requires switch
assisted load balancing, 802.3ad. Virtual Connect
does not support 802.3ad on server downlink ports,
as 802.3ad is a Point-to-Point bonding protocol.
No
Physical NIC Load Introduced in vSphere 4.1 and only available with a
vDS, Load-Based Teaming policy monitors the flow
when the mean send or receive utilization on a
dvUplink exceeds 75% capacity over 30-sec intervals.
Yes
Explicit Failover Highest order uplink from the list of Active pNICs. Yes
Modifying Server Profiles with Online Servers
HP fully supports modifying Server Profiles while hosts are still online. For older generation servers,
there are specific minimum NIC driver and firmware revisions required. Please review the Virtual
Connect Release Notes, and the Service Pack for Proliant Release Notes.
HP NC551 and NC553 Minimum Supported Firmware and Drivers
The table lists the minimum support firmware and driver revisions for the Emulex OneConnect-based
adapters from HP:
Table 2-4 Supported minimum versions
Component Version
Firmware 4.0.360.15
Driver (Ethernet) 4.0.355.1
Driver (FC/FCoE) 8.2.2.105.36
When multiple NC55x devices are used on a single host, you may experience an issue where not all
of the FlexNICs will appear within the ESXi kernel when using the 4.0.3551. To resolve this, you
must adjust the be2net driver heap stack allocation. Please refer to the HP Customer Advisory
c032201409 on the process and any future updates.
9 http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c03220140
11
Appendix A: Virtual Connect Bill of Materials
Table A-1 Virtual Connect FlexFabric module Mapped VLAN BoM
Partnumber Description Qty
571956-B21 HP Virtual Connect FlexFabric Module 4
AJ716A HP StorageWorks 8Gb B-series SW SFP+ 8
487649-B21 .5m 10Gb SFP+ DAC Stacking Cable 2
455883-B21 10Gb SR SFP+ transceiver 4
Or
487655-B21 3m SFP+ 10Gb Copper DAC 4
Appendix B: Terminology cross-reference
Table C-1 Terminology cross-reference
Customer term Industry term IEEE term Cisco term Nortel term HP Virtual Connect term
Port Bonding or
Virtual Port
Port Aggregation
or Port-trunking
LACP
802.3ad
LACP
Etherchannel or
channeling
(PaGP)
MultiLink
Trunking (MLT)
802.3ad LACP
VLAN Tagging VLAN Trunking 802.1Q Trunking 802.1Q Shared Uplink
Set
12
Appendix C: Glossary of Terms
Table C-1 Glossary
Term Definition
vNet/Virtual Connect Ethernet
Network
A standard Ethernet Network consists of a single broadcast
domain. However, when “VLAN Tunnelling” is enabled within
the Ethernet Network, VC will treat it as an 802.1Q Trunk port,
and all frames will be forwarded to the destined host untouched.
Shared Uplink Set (SUS) An uplink port or a group of uplink ports, where the upstream
switch port(s) is configured as an 802.1Q trunk. Each associated
Virtual Connect Network within the SUS is mapped to a specific
VLAN on the external connection, where VLAN tags are removed
or added as Ethernet frames enter or leave the Virtual Connect
domain.
Auto Port Speed** Let VC automatically determine best FlexNIC speed
Custom Port Speed** Manually set FlexNIC speed (up to Maximum value defined)
DCC** Device Control Channel: method for VC to change either a
FlexNIC or FlexHBA Adapter port settings on the fly (without
power no/off)
EtherChannel* A Cisco proprietary technology that combines multiple NIC or
switch ports for greater bandwidth, load balancing, and
redundancy. The technology allows for bi-directional aggregated
network traffic flow.
FlexNIC** One of four virtual NIC partitions available per FlexFabric
Adapter port. Each capable of being tuned from 100Mb to
10Gb
FlexHBA*** The second Physical Function providing an HBA for either Fibre
Channel or iSCSI functions
IEEE 802.1Q An industry standard protocol that enables multiple virtual
networks to run on a single link/port in a secure fashion through
the use of VLAN tagging.
IEEE 802.3ad An industry standard protocol that allows multiple links/ports to
run in parallel, providing a virtual single link/port. The protocol
provides greater bandwidth, load balancing, and redundancy.
LACP Link Aggregation Control Protocol (see IEEE802.3ad)
LOM LAN-on-Motherboard. Embedded network adapter on the system
board
Maximum Link Connection
Speed**
Maximum FlexNIC speed value assigned to vNet by the network
administrator. Can NOT be manually overridden on the server
profile.
Multiple Networks Link Speed
Settings**
Global Preferred and Maximum FlexNIC speed values that
override defined vNet values when multiple vNets are assigned to
the same FlexNIC
MZ1 or MEZZ1; LOM Mezzanine Slot 1; LAM on Motherboard/systemboard NIC
13
Network Teaming Software A software that runs on a host, allowing multiple network
interface ports to be combined to act as a single virtual port. The
software provides greater bandwidth, load balancing, and
redundancy.
pNIC Physical NIC port. A FlexNIC is seen by VMware as a pNIC
Port Aggregation Combining ports to provide one or more of the following benefits:
greater bandwidth, load balancing, and redundancy.
Port Aggregation Protocol
(PAgP)*
A Cisco proprietary protocol aids in the automatic creation of
Fast EtherChannel links. PAgP packets are sent between Fast
EtherChannel-capable ports to negotiate the forming of a
channel.
Port Bonding A term typically used in the Unix/Linux world that is synonymous
to NIC teaming in the Windows world.
Preferred Link Connection
Speed**
Preferred FlexNIC speed value assigned by a vNet by the
network administrator.
Trunking (Cisco) 802.1Q VLAN tagging
Trunking (Industry) Combining ports to provide one or more of the following benefits:
greater bandwidth, load balancing, and redundancy. See also
Port Aggregation.
VLAN A virtual network within a physical network.
VLAN Tagging Tagging/marking an Ethernet frame with an identity number
representing a virtual network.
VLAN Trunking Protocol (VTP)* A Cisco proprietary protocol used for configuring and
administering VLANs on Cisco network devices.
vNIC Virtual NIC port. A software-based NIC used by VMs
*The feature is not supported by Virtual Connect. **The feature was added for Virtual Connect Flex-10
***The feature was added for Virtual Connect FlexFabric modules
For more information
To read more about the Virtual Connect FlexFabric module, go to www.hp.com/go/virtualconnect
To learn more about HP BladeSystem, go to www.hp.com/go/bladesystem
For additional HP BladeSystem technical documents, go to www.hp.com/go/bladesystem/documentation
Share with colleagues
© Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Trademark acknowledgments, if needed.
4AA2-xxxxENW, March 2012