GE Molded Case Circuit Breakers
F225 Line Circuit Breakers70-250 Amperes-TFJ Noninterchangeable Trip70-225A TFK, THFK Interchangeable Trip480 or 600 volts ac250 Volts dc
Frame
Note: All TFJ, TFK and THFKbreakers are UL listed asHACR. r
Type TFJ—Noninterchangeable TripIncludes line and load lugs. Suitable for reverse feed.
AmpereRating
Adjustable Trip RangeAmp
Lo Hi
Complete Breaker480 Vac Max.
Catalog NumberList
Price,GO-135B
Two-Pole708090
100110125150175200225
250
225NA
600700600600660600700800900
1000
1000
-
9001000900
1250125012501500175020002250
2250
-
TFJ224070WLTFJ224080WLTFJ224090WLTFJ224100WLTFJ224110WLTFJ224125WLTFJ2241 50WLTFJ224175WLTFJ224200WLTFJ224225WL
—
TFJ226Y225®@©
$1122.001122.001122.001122.001122.001122.001122.001122.001122.001122.00
—
803.00
Complete Breaker600 Vac Max.
Catalog NumberList
Price,GO-135B
Three-PoleTFJ236070WLTFJ236080WLTFJ236090WLTFJ236100WLTFJ236110WLTFJ236125WLTFJ236150WLTFJ2361 75WLTFJ236200WLTFJ236225WL
TFJ236250WL
TFJ236Y225CS©
$1407.001407.001407.001407.001407.001407.001407.001407.001407.001407.00
2075.00
1174.00
Copper/Aluminum
Lugs
TCAL24
®
TCAL24
WireSize
#4-300kcmil
®
—
Types TFK, THFK—Interchangeable Trip
AmpereRating
AdjustableTrip Range
Amp
Lo Hi
Complete Circuit BreakerIncludes Line and Load Lugs
Standard
Catalog NumberList
Price,GO-135B
Hi-Break-
Catalog NumberList
Price,GO-135B
Trip Unit Only
Use withStandard
andHi-BreakFrames
ListPrice,
GO-135B
Frame Only
Catalog NumberList
Price,GO-135B
Terminal Lugs forFront Connection
(Copper/Aluminum)® ]
Catalog Number(Order 1 lineand 1 loadper pole)
ListPrice,
GO-135BWireSize
Two-Pole, 480 Volts ac Max., 250 Volts dc Max.708090
100110125150 *175200225
225NA
600700600600660600700aoff-900
1000
—
9001000900
12501250125015004.7502060,2250
—
TFK224070WLTFK224080WLTFK224090WLTFK224100WLTFK224110WLTFK224125WLTFK224150WLTFK224175WLTFK2242QOWL
"TFK229225WL
TFK226Y225®®®
$1122.001122.001122.001122.001122.001122.001122.001122.001122.001122.00
937.00
THFK224070WLTHFK224080WLTHFK224090WLTHFK224100WLTHFK224110WLTHFK224125WLTHFK224150WLTHFK224175WLTHFK224200WLTHFK224225WL
—
$2315.002315.002315.002315.002315.002315.002315.002315.002315.002315.00
-
TFK226T070TFK226T080TFK226T090TFK226T100TFK226T110TFK226T125TFK226T150TFK226T175TFK226T200TFK226T225
TFKY2©
$337.00337.00337.00337.00337.00337.00337.00337.00337.00337.00
148.00
TFK224FOOOStandardFrame
THFK224FOOOHi-BreakFrame
$753.00
1946.00
TCAL24 $8.00 #4-300kcmil
Three-Pole, 600 Volts ac Max., 250 Volts dc Max.708090
100110125150175200225
225AMagOnly
225NA
600700600600660600700800900
1000
6001000
-
9001000900
1250125012501500175020002250
14002250
—
TFK236070WLTFK236080WLTFK236090WLTFK236100WLTFK236110WLTFK236125WLTFK236150WLTFK236175WLTFK236200WLTFK236225WL
——
TFK236Y225® ©
1407.001407.001407.001407.001407.001407.001407.001407.001407.001407.00
——
1174.00
THFK236070WLTHFK236080WLTHFK236090WLTHFK236100WLTHFK236110WLTHFK236125WLTHFK236150WLTHFK236175WLTHFK236200WLTHFK236225WL
——
-
2787.002787.002787.002787.002787.002787.002787.002787.002787.002787.00
——
-
TFK236T070TFK236T080TFK236T090TFK236T100TFK236T110TFK236T125TFK236T1 50TFK236T175TFK236T200TFK236T225
TFK236TM1225®TFK236TM2225®
TFKY3©
445.00445.00445.00445.00445.00445.00445.00445.00445.00445.00
555.00555.00
208.00
TFK236FOOOStandardFrame
THFK236FOOOHi-BreakFrame
914.00
2294.00 TCAL24 g f\e\O.UU#4-300kcmil
® Molded-case switch. Completeswitch includes line and loadlugs. UL listed only whenordered as a complete switch.
Internal accessory installationrequires dummy trip unit. Seepage 4-51 for additionaldetails.
© Not UL listed.® For optional lugs, see page
4-62.© 600 volts maximum.
® TC024 load end. Wire range#4-300 kcmil copper only.
Accessories:See pages 4-48 to 4-65.
4-22 1999 Issue Prices and data subject to change without notice
GF Molded Case Circuit Breakers
Molded Case Circuit Breakers ,Spectra RMS™, Spectra RMS™ with MicroVersaTrip Plus™ Trip Units, Spectra RMS™ withMicroVersaTrip PM™ Trip Units, Thermal Magnetic and J/K with MicroVersaTrip® HMS-9 andPower+™ 4 Trip Units
How to OrderQLine• Thermal Magnetic Circuit Breakers• Molded-Case Switches
The catalog number as shown in the following pages includes thecomplete breaker or switch. TQD and TJD breakers are completewith Cu/AI line and load lugs.Spectra RMS™• Circuit Breakers
Determine the required breaker frame, 1C rating, and loadrequirements. Select frame, trip unit (rating plug), and lug, ifrequired, catalog numbers from the tables on pages 4-18 and4-19. Select field-mounted internal accessory catalog numbers,if required, on page 4-47. Select field-mounted externalaccessory catalog numbers, if required, on pages 4-48 through4-65. Order as separate items. For Spectra breakers withMicroVersaTrip Plus Trip Units or MicroVersaTrip PM Trip Unitsrefer to page 4-26 through 4-35.
• Mag-Break Motor Circuit ProtectorsDetermine the required frame and ampere requirements.Select frame, trip unit (rating plug), and lug, if required, catalognumbers from the table on page 4-42. Select accessories asnoted above for circuit breakers. The same accessories areused with both circuit breakers and motor circuit protectors.Order as separate items.
• Molded-Case SwitchesDetermine the required frame and ampere requirements.Select frame and lug, if required, catalog numbers from the tableon page 4-20. Rating plugs are not used. Select accessories asnoted above for circuit breakers. Internal accessories do notrequire dummy trips. The same accessories are used with bothcircuit breakers and molded-case switches. Order as separateitems.
Unless otherwise noted, all circuit breakers are UL listed in File E-11592.Molded-case switches are UL listed in File E-57546. Field-InstallableInternal Accessories are UL listed in File E-57253. Distribution CableAccessories for MicroVersaTrip Plus Trip Units and MicroVersaTrip PM TripUnits are UL listed in File E-57253.
E150 LineThermal Magnetic Circuit BreakersMagnetic Circuit BreakersMolded-Case Switches
The catalog numbers as shown in the following pages include thecomplete breaker or switch. All devices listed come with Cu/AI lineand load lugs. If line lugs are not required on a breaker, eliminate"WL" from catalog number; for molded-case switches see page4-3. Unless otherwise noted, all circuit breakers are UL listed inFile E-11592. Molded-case switches are UL listed in File E-57546.F 225 Line• Thermal Magnetic Circuit Breakers• Magnetic Circuit Breakers• Molded-Case Switches
These breakers are available with either noninterchangeable trips(designated Type TFJ) or interchangeable trips (designated TypesTFK/THFK). When ordering Type TFJ, catalog number includes
complete breaker, trip unit, Cu/AI line and load lugs factoryassembled. If line lugs are not required on a breaker, eliminate"WL" from catalog number, and subtract price of line lugs fromprice of complete breaker. If interchangeable trip (Types TFK/THFK) is required order one of two ways. "Complete circuitbreaker" price includes frame, trip, Cu/AI line and load lugs. Unitswill be shipped unassembled unless specified on order "must befactory assembled." If line lugs are not required on a breaker,eliminate "WL" from catalog number, and subtract price of linelugs from price of complete breaker. To order the frame, trip, andlugs separately, select the required components from table.Magnetic breakers must be ordered as components. A completebreaker consists of frame, trip unit, one line lug per pole and oneload lug per pole. Price of "Complete Circuit Breaker" vs. orderingframe, trip, and line and load lugs separately is the same.Molded-case switches can also be ordered as complete units(designated TFK—Y) or as separate components. They are ULlisted only as complete units. To indicate required lugs, seepage 4-3.Unless otherwise noted, all circuit breakers are UL listed in FileE-11592. Molded-case switches are UL listed in File E-57546.J 600 Line• Thermal Magnetic Circuit Breakers• Magnetic Circuit Breakers• Molded-Case Switches -These breakers are available with either noninterchangeable trip(designated Type TJJ) or interchangeable trip (designated TypeTJK and THJK). Type TJJ catalog numbers include frame, trip,Cu/AI line, and load lugs factory assembled. If line lugs are notrequired on the breaker, eliminate "WL" from catalog number, andsubtract price of line lugs from price of complete breaker.TJK breakers are available in two frames, 400 ampere frame(125 to 400 amperes) and 600 ampere frame (250 to 600 • .amperes). Trip units are not interchangeable between frames."Complete Circuit Breaker" price includes frame, trip unit, Cu/AIline, and load lugs. Unit will be shipped unassembled unless orderspecifies "must be factory assembled." If line lugs are notrequired, eliminate "WL" from catalog number and subtract priceof line lugs from price of complete breaker.To order the frame, trip, and lugs separately, select the requiredcomponents from table. Magnetic breakers must be ordered ascomponents. A complete breaker consists of frame, trip, and oneline and one load lug per pole.Price of ordering "Complete Circuit Breaker" vs. frame, trip, andline and load lugs separately is the same.Molded-case switches can also be ordered as complete units(designated Type TJK—Y) or as separate components. They areUL listed only as complete units. To indicate required lugs, seepage 4-3.Unless otherwise noted, all circuit breakers are UL listed in FileE-11592. Molded-case switches are UL listed in File E-57546.
(continued on next page)
4-2 1999 Issue Data subject to change without notice
GE Molded Case Circuit Breakers
K1200 Line• Thermal Magnetic Circuit Breakers• Magnetic Breakers• Molded-Case SwitchesThese breakers are available only with interchangeable trip units.Two frame sizes are available, the 800 ampere frame (300 to 800amperes) and the 1200 ampere frame (600 to 1200 amperes). Tripunits are not interchangeable between frames.
"Complete Circuit Breaker" price includes frame, trip, Cu/AI line,and load lugs. Units will be shipped unassembled unless specified"must be factory assembled." If line lugs are not required on thebreaker, eliminate "WL" from catalog number and subtract priceof line lugs.
To order the frame, trip, and lugs separately, select the requiredcomponents from table. Magnetic circuit breakers must beordered as components. A complete breaker consists of frame,trip and one line and one load lug per pole. Price of ordering"Complete Circuit Breaker" vs. frame, trip, and line and load lugsseparately is the same.
Molded-case switches can also be ordered as complete units(designated Type TKMA—Y) or as separate components. Theyare UL listed only as complete units. To indicate required lugs,see the table below.
x Unless otherwise noted, all circuit breakers are UL listed in FileE-11592. Molded-case switches are UL listed in File E-57546.R Frame—1000/1600/2000 Amp Molded-Case Circuit Breakers• Solid-state MicroVersaTrip Plus™ or MicroVersaTrip PM™
Trip Unit• Interchangeable trip unit via rating plugs• 65 and 100 kA ratings available• Standard and 100% rated versions• Uses standard Power Break* accessories• Stationary/manual onlyCurrent Limiting Circuit Breakers• 150, 225, 400 and 600 ampere frame sizes• UL listed interrupting ratings are 200 kA at 240 and 480 volts ac
maximum and 50 kA at 600 volts ac maximum• Thermal magnetic constructionCircuit Breakers with MicroVersaTrip' Trip Units• Solid-state construction with MicroVersaTrip RMS-9 digital rms
sensing microprocessor trip units.• Available in J and K frame construction with ampere ratings from
60-1200A.For ordering information see pages 4-36 through 4-41. UL listed,File E-11592. All breakers are UL listed in File E-11592.Tri-Break' Line• Integrally Fused Thermal Magnetic Circuit Breakers• Integrally Fused Magnetic Circuit Breakers• Integrally Fused Molded-Case Switches
Molded Case Circuit BreakersThese breakers are available in four types. Type TB1 (15-100amperes) catalog numbers include frame, trip, line and load lugs,and current limiters all factory assembled. Types TB4 (125 to 400amperes), TB6 (300 to 600 amperes) and TB8 (600 to 800 amperes)include frame, trip and limiters, factory assembled, but do notinclude line or load lugs. If line and load lugs are required, orderseparately. Unless otherwise noted, TB1, TB4, TB6, and TB8breaker components are UL listed in File E-42263. Fusedmolded-case switches are UL listed in File E-57546.Mag-Break9 Line• Magnetic only circuit breakers (motor circuit protectors)
These breakers are available only with noninterchangeableadjustable magnetic trip, in frame Types E, F, J, K, and Tri-Break.All breakers are shipped factory assembled, complete with Cu/AIline and load lugs.
All magnetic only circuit breakers and limiters are UL ComponentRecognized in Files E-11592 and E-66390, respectively, unlessotherwise noted.
AccessoriesOrder accessories from the appropriate table:
Thermal Magnetic Circuit Breakers, Magnetic Circuit Breakers, andMolded-Case Switches®—pages 4-48 to 4-65.MicroVersaTrip RMS-9 or 4-function Solid-State Circuit Breakers— .pages 4-48 to 4-65.
© Installation of accessories in molded-case switches requires dummytrip; see page 4-51 for information. Dummy trip not required forTri-Break or Q Line molded-case switches.
Spectra RMS™ Breakers—pages 4-47 to 4-65.Spectra RMS™ Breakers with MicroVersaTrip Plus™ Trip Units orMicroVersaTrip PM™ Trip Units—pages 4-32 to 4-35 and 4-47 to 4-65.
Molded-Case Circuit Breaker and SwitchTerminal Configuration CodeOrder standard Cu/AI lugs by using suffix codes presented. Order lugsseparately if special lugs are required. For optional lugs, see page 4-62.
Breaker/SwitchType
TQD/TJD
Molded CaseBreakers,ThermalMagneticMoldedCaseSwitchSpectra RMS™BreakersJ.K.MicroVersaTrip"BreakersMine Duty™BreakersMag- Break*Breakers
Suffix
BlankLoadLugsOnly
LoadLugsOnly
Line andLoadLugsNo
Lugs
NoLugs
NoLugs
Line andLoad Lugs
WL
Line andLoad Lugs
Line andLoad Lugs
-
XL
-
-
NoLugs
X2LineLugsOnly
LineLugsOnly
LineLugsOnly
LL
NoLugs
NoLugs
LoadLugsOnly
Order Lugs Separately
Order Lugs Separately
Order Lugs Separately
- - - —
For E 150 circuit breakers suffix XL is used to specify "no lugs".
Data subject to change without notice 1999 Issue 4-3
pi N II
GE Molded Case Circuit Breakerst. VERTICAL Molded Case Circuit Breakers
Quick Reference GuideRatings do not apply to molded-case switches.
TJJ, TJK, THJK TFJ, TFK, THFK
E150 (UL File E-11592; Fixed Thermal Magnetic Trip Unit; CSA LR 57114)
Jlte^
CircuitBreakerType
TEY®
TEB®
TED®
THED®
TEL®
AmpereRating
15-100
10-1009>
10-100
15-10010-150
15-30
15-100
15-1001 1 0 - 1 5 0
-15-150
No.Poles
12
3
1
2
3
1
2 '
3
1
2
3
3
MaximumVoltage Rating
ac277
120
277,347®480
600
277,347®
480
480,600
600
do125
250
125
250
—
125
250
500
125
250
-
UL Listed Interrupting Ratings—rms Symmetrical Amps (In Thousands)ac Voltage
12065
10
-
-
120/240
-
—
-
100
240
14
65
—
10
—
18
—
65
65
42
100
277
14
1 4
-
14
65
-
-
480
-
-
10
1 8
—
25
65
600
-
-
—
—
1 4
—
18
25
do Voltage1251 01 0—
5——
10
20®
-
-
250
—
1 0
—
5
—
—
10
10
—
20®
10
-
500®—
—
—
—
—
—
10
—
—
-
Dimensions(In.)
H
5'/4
65/ie
6^16
65/16
65/ie
W
1
2
3
1%
2%'
4Vfr
1%
23/4
41*
1%
41/a
4'/B
D
3'/18
3%
3%
3%
ytte
A
-
24'/64
Z"A>
2"/tn
27/16
B
-
2'%4
21%4
21s/64
2'%2
c
-
"/16
__
1 '/16
——
"/,6
11/16
E
-
s%2
23/32
2%2
2%2
Approx.Ship Wt./Std. Pack
26 lb/2424 lb/1 2
28 lb/8
26 lb/24
24lb/1228 lb/8
26 lb/24
24lb/12
28 lb/8
3Vz lb/1
"225 (UL File E-11592; TFJ, Fixed Thermal Magnetic Trip Unit; TFK, THFK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
CircuitBreaker
Type
TFJ®
TFK®
THFK®
TFL®
AmpereRating
70-225
70-250
70-225
70-225
70-225
No.Poles
2
3
2
3
2
3
3
MaximumVoltage Rating
ac480
600
480
600
480
600
600
dc
250
500
250
—
250
—
-
UL Listed Interrupting Ratings —rms Symmetrical Amps (In Thousands)ac Voltage
120
-
120/240
100
240
25
25
65
100
277
-
480
22
22
25
65
600
—
1 8
_
18
—
1 8
25
dc Voltage125
-
2501 0
10®
10
—
20®
—
-
500®—
10
—
—
_
—
-
Dimensions(in.)
H
10'/8
101*
10'/B
101*
W
41*
4%
41*
'41*
D
3'Vie
31yi«
3^18
3«/16
A
3%
3%
37/6
3%
B
3'/B
3%
3%
3%
C
"/16
"/,e
"/16
11/16
E
1 3 /16 •
1*i6
1Vie
1*ie
Approx.Ship Wt./Std. Pack
10 lb/1
12 lb/110 lb/112 lb/110 lb/112 lb/1
-
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit; CSA LR 40350)
TJK4
THJK4
250-600
250-600
2
3
2
3
2
3
2
3
600
600
250
500
250
500
250
—
250
-
42
65
30
35
2210
20
10
20®
40
—
40
-
—
' 20®
—
20
—
—
—
_
81/4
3'3/16
3%
315/16 3^16
3«/16
1% 1*6
16lb/117'/2lb/1
18 lb/120 lb/116 lb/1
17Vzlb/1
18 lb/120 lb/1
K1200 (UL File E-11592; Interchangeable Thermal Magnetic Trip Unit; CSA LR 40350)
TKM8
TKM12
THKM12
2
3
2
3
2
3
2
3
600250
500
250
—
42
65 35
.2210
20 <D
40®
—
—
22
—
—8'/4
5'/2
5/2
SQ/IB
5"/16
1%
1%
%
%
33 lb/1
39 lb/138 lb/1
41VMW133 lb/139 lb/138 lb/1
41 14 lb/1
UL listed with poles in seriesfor 500 Vdc ungroundedbattery applications.
© All UL listed as HACR type.® 10 amp not UL listed.
® UL listed/CSA Certified for10kA @ 347 Vac (TED) and18kA@ 347V (THED). Alsorated 10kA @ 480V but notUL listed.
© UL listed at 10,000 amps.® Discontinued© Also 10,000 amps at 500 Volts
dc. Not UL listed.
500 Vdc on TJJ only.
(continued on page 4-8)