LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
Addendum of the user manual: Fire brigade solutionThe fire brigade solution according to EN81-72 from the Leitronic AG can be used by new installations or by back fitting. The System combines the fire brigade communication according to EN81-72 and the normal emer-gency call according to EN81-28 and EN81-70. Additional to the components from the Leitronic an analogue land line connection, a screened two or four wire cable (to the fire brigade location, to the cabin and to the machine room) and the supply is required.
1 Overview..............................................................................................1 2 Components.........................................................................................2
2.1 In the cabin..................................................................................2 2.2 On the fire brigade location and in the machine room..................2
3 Overview schema installation with EA-8-DPXM...................................4 4 Overview schema installation with EXICALL EN70MR........................5 5 Installation machine room and fire brigade location.............................6 6 Connectors and technical data LMK72B-WG.......................................7 7 Mechanical drawing.............................................................................8
7.1 LMK72B-WG / LMK70x-WG.........................................................8 7.1.1 Suggestion for panel from Schäfer GmbH...........................8
7.2 Machine room - Box.....................................................................9 7.2.1 EA-IP-BOX-EN72 (until 2013)..............................................9 7.2.2 EA-IP-EN72 (from 2014)......................................................9
1 Overview
The talking-mode is indicated with the green “Talk”-Symbol. The listening-mode is indicated with the yellow “Listen”-Symbol. No connection time-out. An emergency call in the cabin has higher priority than fire brigade mode. The volume can be adjusted on the LMK.
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 1/8
Fire brigade location
Button
Symbol
Machine room
Button
Symbol
Activation of the fire brigade mode with the key switch at the fire brigade location.
The microphone in the cabin is now activated (talk); Machine room and fire brigade location hear the cabin.
Push the speak button . The microphone on that location becomes activated (talk) and the other locations are on reception (listen).
Cabin
Symbols
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
2 Components
2.1 In the cabina) Version EasyAlarm
+EA-8-DPXM EA-LMK70x-WGSet Article-No.: EA8 DPXM LMK70x-WG
b) Version Exicall EN70MR
Exicall EN70MRArticle-No.: 121.5104 (vertical) or 121.5105 (horizontal)
2.2 On the fire brigade location and in the machine room
+ + EA-LMK72B-WG Keys switch Button TalkArticle-No.: 118.0202B not included not included
Internal LED indicators with light-pipes to front panelorexternal symbols
Listen Talk
You may also choose a ready to use box in an IP-housing or a panel / incl. button(s) and indicators:
EA-IP-BOX-EN72 EA-IP-EN72 EA-TAB-EN72Article-No.: 118.0212B ( 7.2.1) Article-No.: 118.0212BS ( 7.2.2) Article-No.: 100.0223until 2013 from 2014
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 2/8
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
3 Overview schema installation with EA-8-DPXM
Order information:Cabin: EA8 DPXM LMK70x-WG (incl. 1xEA-8-DPXM + 1xLMK70x-WG)Fire brigade Art.No: 118.0202B LMK72B-WGMachine room Art.No: 118.0202B LMK72B-WG
Option:Machine room ready to use Art.No. 118.0212B LMK72B-WG mounted in EA-IP-BOX-EN72 ( 7.2.1)Machine room ready to use Art.No. 118.0212BS LMK72B-WG mounted in EA-IP-EN72 ( 7.2.2)
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 3/8
8 .. 35 VDC
8 .. 35 VDC
Button
EA-8-DPXM
PSTN: 3/4 rt/gr
Free potential (elev. control)
2
2 x twisted pair, isolated from other cables
8 .. 35 VDC
LMK70x-WG
Cabin Installation according to manual EasyAlarm ELEVATOR
Machine room Optional: IP-Box ( 7.2) Installation according to section 4
Fire brigade location Installation according to section 4
Apply supply for • fire brigade-mode • machine-room-mode
-potential: Pass all cable isol-ated form other potential
Button
Key switch for the fire bri-gade mode
Adjustable volume
4
Twisted pair, isolated from other cables
3
/4 r
e/g
n
2
/5 b
l/ye
3
/4 r
e/g
n
3/4
re
/gn
EX
TL
INE
LMK72B-WG
LMK72B-WG
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
4 Overview schema installation with EXICALL EN70MR
Order information:Cabin: Art.No: 121.5104 Exicall EN70MR vertical mounting
Art.No: 121.5105 Exicall EN70MR horizontal mountingFire brigade Art.No: 118.0202B LMK72B-WGMachine room Art.No: 118.0202B LMK72B-WG
Option:Machine room ready to use Art.No. 118.0212B LMK72B-WG mounted in EA-IP-BOX-EN72 ( 7.2.1)Machine room ready to use Art.No. 118.0212BS LMK72B-WG mounted in EA-IP-EN72 ( 7.2.2)
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 4/8
10 .. 35 VDC
8 .. 35 VDC
EXICALL EN70MR
8 .. 35 VDC
Machine room Optional: IP-Box ( 7.2) Installation according to section 4
Fire brigade location Installation according to section 4
Cabin Installation according to manual EXICALL EN70MR
Button
Button
2 x twisted pair, isolated from other cables4
2
PSTN: 3/4 rt/gr
3
/4 r
e/g
n
2
/5 b
l/ye
Free potential (elev. control)
-potential: Pass all cable isol-ated form other potential
LMK72B-WG
LMK72B-WG
Apply supply for • fire brigade-mode • machine-room-mode
Key switch for the fire brigade mode
Twisted pair, isolated from other cables
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
5 Installation machine room and fire brigade location
Be aware, that there is NO water protective foil between panel and the LMK-housing. Otherwise it will affect commu-nication quality!
EA-LMK72B-WG
Telephone-Line
Connect telephone wires -2/5 (bl/ye) of cabin unit to X1-1 and X1-2Talk-button
Connect Talk-button (Normally open) to terminal X2-1 and X2-2Optional opto-input: signal 10 .. 50 V AC/DC between the two X7-Talk(IN)
Supply voltage
Connect switched supply voltage (8 .. 35 VDC) to terminal X7-VIN(+) and X7-VIN(-)=> Key switch activates fire brigade mode
Internal LED with light pipe to front panel or optional external indicators
Optional: Connect Listen-Indicator to terminal X7-VIN(+) and X7-Lamp1(-) (max. 130 mA). Optional: Connect Talk-Indicator to terminal X7-VIN(+) and X7-Lamp2(-) (max. 130 mA).
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 5/8
-potentialPass all cable (max. 3m) isolated form other po-tential.
X2
2-wiresX7
EXT
Free potential (elev. control)
To cabin telephone wires 2/5 (bl/ye)
Key switch
VIN(-)VIN(+)VIN(+)Lamp1(-)VIN(+)Lamp2(-)
Speak (INSpeak (IN)
SpeakButton
X1
!
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
6 Connectors and technical data LMK72B-WGPlug X7 (free potential)
PIN Description Specification Function 1 VIN(-) 8 .. 35 VDC
max. 330 mASupply voltage = fire brigade mode
2,3,5 VIN(+)4 Lamp1(-) Open Collector- output
(- will be switched)max. 130 mA/outputtotal 1.1A (fuse)
Yellow lamp (Listen)
6 Lamp2(-) Green lamp (Talk)
9 Talk (IN) Opto coupler-input10..50V (AC or DC)
Talk-Signal10
Plug X1 (on -potential)
Plug X2 (on -potential)
X1X7
X2EXT-Jack (on -potential)PIN Description Specification1 LS+ on -potential2 OUT on -potential3 Emergency contact on -potential4 +12V on -potential5 Sensor 1 on -potential6 GND on -potential7 Sensor 3 on -potential8 MIC+ on -potential
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 6/8
PIN Description Specification1 Tel a on -potential2 Tel b on -potential
PIN Description Specification1 Talk-button NO on -potential2 Talk-button C on -potential
12
12
10
1
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
7 Mechanical drawing
7.1 LMK72B-WG / LMK70x-WGMaterial: ABSDimension: 112 x 56 x 21 mm (L x W x H) without plug
112 x 74 x 21 mm (L x W x H) incl. plug Weight: 100 g (without connection cable)
7.1.1 Suggestion for panel from Schäfer GmbH Attention: Please check that there will be NO water protective foil between panel and LMK-housing
Order code: "G9924wg LMK70-LED" with holes for light pipes and EN81-70 engravingOrder code: "G9924wg LMK72-LED" with holes for light pipes and EN81-72 engraving
or "G9924wg LMK70" with external symbols: i.e. Type RA42-WG (Schäfer) or similar.
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 7/8
Ø4
Ø2.6
14.4
30
LEITRONIC AGSwiss Security SystemsFire Brigade solution according to EN81-72 04/06/2014
7.2 Machine room - Box Water resistant hole pattern for LMK72B-WG Talk button: RT-42 2M Sonder Leitronic WG / Symbol Sprechen / Fremdartikelnr: 10008 (12V)Listen symbol: RA-42 Sonder Leitronic WG / Symbol Lautsprecher / Fremdartikelnr: 10011 (12V)
7.2.1 EA-IP-BOX-EN72 (until 2013)Art. No. 118.0212B Dimension: 240 x 190 x 110 mm (L x W x H) Housing
260 x 190 x 113 mm (L x W x H) Housing assembled incl. M16 feed throughWeight: 1200 g (completely assembled / without cables)
7.2.2 EA-IP-EN72 (from 2014)Art. No. 118.0212B2Dimension: 110 x 180 x 64 mm (L x W x H) unmountedWeight: 400 g (completely assembled / without cables)
)
EA8-EXIMR-FWS-MIN-Set-GB-2013.odt +41 (0)56 648 40 40 www.leitronic.ch Page 8/8