SWITCH, MOUNTED 48" AFF.
BLANK = SINGLE POLE
P = WITH PILOT LIGHT
WP= WEATHER PROOF
OS= OCCUPANCY SENSOR
3W= 3-WAY
D=DIMMER
ELECTRICAL SYMBOLS - LIGHTING
EXIT SIGN, WALL / CEILING MOUNTED WITH DIRECTIONAL ARROWS AND FACES
AS SHOWN.
EXIT SIGN, CEILING MOUNTED WITH DIRECTIONAL ARROWS AND FACES AS
SHOWN.
RECESSED FIXTURE WITH 1000 LUMEN LED.
DISCONNECT SWITCH, FUSED
DISCONNECT SWITCH, UNFUSED
ELECTRICAL SYMBOLS - POWER
JUNCTION BOX
TRANSFORMER, PLAN
MOTOR, SINGLE-PHASE
MOTOR, THREE-PHASE
BRANCH CIRCUIT HOMERUN. LINES INDICATE NUMBER OF CIRCUITS, NEUTRAL,
AND SWITCH LEG CONDUCTORS. ONE SEPARATE GREEN GROUNDING
CONDUCTOR SHALL BE PROVIDED FOR EACH HOMERUN; NOT SHOWN. #12
CONDUCTORS UNLESS OTHERWISE NOTED OR SCHEDULED.
LIGHTING PANELBOARD, SURFCE MOUNTED.
POWER AND RECEPTACLE PANELBOARD, SURFACE MOUNTED.
DUPLEX RECEPTACLE MOUNTED AT 18" A.F.F.
A. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL
REFLECTED CEILING PLANS.
B. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALL
HAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR.
C. EACH 120/277 BRANCH CIRCUIT HOMERUN SHALL HAVE INDIVIDUAL PHASE AND NEUTRAL CONDUCTORS, SHARING OF
NEUTRALS SHALL NOT BE ALLOWED.
EARTH GROUND
1PH SINGLE-PHASE
1P SINGLE POLE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE-PHASE
3W THREE-WIRE
4/C FOUR-CONDUCTOR
4W FOUR-WIRE
AC ABOVE COUNTER 6" 0R 42" AFF
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMP AMPERE
ARCH ARCHITECT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BLDG BUILDING
BRKR BREAKER
C CONDUIT
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CKT CIRCUIT
CU COPPER
DS DISCONNECT SWITCH
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMT ELECTRICAL METALLIC TUBING
ELECTRICAL ABBREVIATIONS
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FLA FULL LOAD AMPS
GND GROUND
GEN GENERATOR
GFI GROUND FAULT CIRCUIT INTERRUPTER
HID HIGH INTENSITY DISCHARGE
HP HORSEPOWER
IMC INTERMEDIATE METAL CONDUIT
J-BOX JUNCTION BOX
kV KILOVOLT
kVA KILOVOLT AMPERE
kW KILOWATT
LED LIGHT EMITTING DIODE
LRA LOCKED ROTOR AMPS
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
P POLE
PH PHASE
PNL PANEL
PVC POLYVINYL CHLORIDE (PLASTIC)
RECPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
SF SQUARE FOOT (FEET)
SI INTERNATIONAL SYSTEM OF UNITS
TC TIME CLOCK
TEL TELEPHONE
TTB TELEPHONE TERMINAL BOARD
TYP TYPICAL
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VA VOLT AMPERE
VOLT VOLTAGE
W WATT
WP WEATHERPROOF
XFMR TRANSFORMER
GENERAL ELECTRICAL NOTES:
1. ALL AC POWER CIRCUITS SHALL INCLUDE GREEN GROUND CONDUCTOR SIZED PER NEC, #12 AWG MINIMUM.
GROUND CONDUCTORS ARE NOT SHOWN ON PLANS.
2. ALL ELECTRICAL PANELS SHALL HAVE A TYPEWRITTEN PANEL SCHEDULE.
3. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NATIONAL AND LOCAL ELECTRICAL CODES AND SHALL COMPLY WITH THE
AMERICANS WITH DISABILITIES ACT (A.D.A.) REGULATIONS AS PUBLISHED IN FEDERAL REGISTER/VOLUME 56, NUMBER 144/
RULES AND REGULATIONS AND ALL CURRENT AMENDMENTS.
4. ALL CONDUCTORS SHALL BE COPPER, #12 AWG IN 3/4" CONDUIT MINIMUM, UNLESS OTHERWISE NOTED.
5. CONTRACTOR SHALL VISIT PROJECT SITE PRIOR TO HIS BID TO BECOME AWARE OF WORKING CONDITIONS AND TYPE,
SIZE, AND QUANTITY OF DEVICES, ETC. TO BE REMOVED OR RELOCATED.
6. ALL ELECTRICAL DEVICES SHALL BE CONNECTED BY INSTALLING CONDUCTORS 360° AROUND AND UNDER THE
SCREW TERMINALS. WHEN STRANDED CONDUCTORS ARE USED, PROVIDE SOLID PIGTAIL AND CONNECT.
7. ALL HOLES DRILLED THROUGH EXTERIOR WALLS SHALL BE SEALED WATER TIGHT.
8. ALL HOLES THROUGH INTERIOR WALLS OR FLOORS SHALL BE FILLED WITH FIRE STOP WITH MINIMUM 1 HOUR RATING.
WHEN WALL PENETRATIONS OCCUR WHERE BUILDINGS JOIN, PROVIDE FIRE STOP WITH MINIMUM 2 HOUR RATING.
9. REMOVAL OF DEBRIS: COMBUSTIBLE MATERIALS AND RUBBISH SHALL NOT BE ALLOWED TO ACCUMULATE ON THE SITE AND
SHALL BE HAULED AWAY DAILY OR AS OTHERWISE DIRECTED. LEAVE THE PREMISES IN A SAFE AND CLEAN CONDITION AT
ALL TIMES.
10. ALL CEILING MOUNTED DEVICES SHALL BE MOUNTED IN THE CENTER OF THEIR RESPECTIVE AREA UNLESS OTHERWISE
INDICATED ON PLANS.
11. THE FOLLOWING DEFINITIONS SHALL APPLY:
A. PROVIDE- INDICATES THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ITEM.
B. INSTALL- INDICATES THE ELECTRICAL CONTRACTOR SHALL INSTALL ITEM FURNISHED BY OTHERS.
C. FURNISH- INDICATES THE ELECTRICAL CONTRACTOR SHALL FURNISH ITEM FOR INSTALLATION BY OTHERS.
12. SURFACE RACEWAY SHALL BE USED WHERE WHERE EXPOSED WIRING IS REQUIRED IN FINISHED AREAS. ALL EXPOSED
SURFACE RACEWAY SHALL BE PAINTED TO MATCH SURROUNDING COLOR(S).
RECEPTACLE NOTES;
1. ALL RECEPTACLES SHALL BE GROUND FAULT CIRCUIT INTERRUPTER TYPE
UNLESS OTHERWISE NOTED OR INDICATED ON PLAN.
2. ALL RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS SHALL HAVE
WEATHERPROOF COVERPLATE.
OS
GENERAL LIGHTING NOTES:
1. LOWER CASE LETTERS, WHEN USED, INDICATES CIRCUIT CONTROLLED
VIA LIGHTING CONTROL SYSTEM OR LOCAL DEVICE INDICATED.
2. NUMERAL, WHEN USED, INDICATES CIRCUIT NUMBER.
3. "A1", "F1", ETC. ARE LIGHTING FIXTURE DESIGNATIONS PER THE LIGHT
FIXTURE SCHEDULE.
F1,2a
SQUARE RECESSED FIXTURE WITH 1000 LUMEN LED LAMP.
ELECTRICAL SHEET LIST:
SHEET-NO.SHEET TITLE
E001ELECTRICAL SYMBOLS AND ABBREVIATIONS
RECESSED FIXTURE WITH 1000 LUMEN LED WITH EMERGENCY BATTERY PACK.
GFI
WP
1x4 SURFACE LIGHT FIXTURE WITH TWO 32W T8 LAMPS PER FOUR FOOT SECTION.
DUPLEX RECEPTACLE MOUNTED AT 18" A.F.F.
ELECTRICAL COMMUNICATIONS SYMBOL LIST
DATA OUTLET WALL MOUNTED AT 18" A.F.F.
TELEPHONE ONLY OUTLET WITH 3/4" CONDUIT STUBBED INTO ACCESSIBLE CEILING.
"W", WHEN USED, INDICATES WALL MOUNTED DEVICE. COORDINATE OUTLET MOUNTING FOR UPPERMOST
TELEPHONE OPERATOR TO BE AT A MAXIMUM OF 54" A.F.F.
W
GENERAL LIGHTING NOTES:
CABLE TELEVISION OUTLET WITH POWER MOUNTED AT 8'-0" A.F.F. UNLESS OTHERWISE INDICATED.
RECESSED DIVIDED FLOOR OUTLET WITH DATA, VOICE AND NORMAL POWER.
RECESSED DIVIDED FLOOR OUTLET WITH DATA, VOICE AND GENERATOR POWER.
RECESSED DIVIDED FLOOR OUTLET WITH DATA, VOICE, NORMAL POWER AND GENERATOR POWER.
CEILING MOUNTED WIRELESS ACCESS POINT WITH DATA CABLING AND GENERATOR POWER AS
REQUIRED. FIELD VERIFY OUTLET AND DEVICE CONFIGURATIONS.
QUADRUPLEX RECEPTACLE MOUNTED AT 18" A.F.F.
LINEAR LED UTILITY FIXTURE WEATHERPROOF FLUORESCENT FIXTURE WITH
FIBERGLASS HOUSING.
LEVEL 1 LIGHTING PLANE211
LEVEL 1 LIGHTING PLAN - CONFERENCEE211A
LEVEL 2 LIGHTING PLANE221
FIRE ALARM SYSTEM SYMBOL LIST
SMOKE DETECTOR
H
H
SD
DUCT DETECTOR
HORN ONLY
HORN STROBE
M
DD
MANUAL PULL STATION
TAMPER SWITCH
HEAT DETECTOR
HD
SQUARE RECESSED FIXTURE WITH 1000 LUMEN LED LAMP WITH EMERGENCY BATTERY PACK.
LEVEL 3 LIGHTING PLANE231
X1
X1
VISUAL ONLY
V
TS
FLOW SWITCH
FS
LEVEL 1 POWER PLAN
LEVEL 1 POWER PLAN - CONFERENCE
LEVEL 2 POWER PLAN
LEVEL 3 POWER PLAN
LEVEL 1 SYSTEMS PLAN
LEVEL 1 SYSTEMS PLAN - CONFERENCE
LEVEL 2 SYSTEMS PLAN
LEVEL 3 SYSTEMS PLAN
ROOF POWER PLAN
ENLARGED ELECTRICAL PLANS - TYPICAL GUEST ROOM UNITS
ENLARGED ELECTRICAL KITCHEN AREA PLAN
LIGHT FIXTURE & PANEL SCHEDULES
ELECTRICAL RISER DIAGRAMS
E311
E311A
E321
E331
E411
E411A
E421
E431
E500
E501
E600
E700
E341
AR
ADDRESSABLE RELAY
SITE ELECTRICAL PLANE100
ROOF POWER PLAN - CONFERENCEE341A
2x4 DIRECT/INDIRECT PENDANT LIGHT FIXTURE WITH THREE 54W T5-HO LAMPS WITH
EMERGENCY BATTERY PACK.
2x4 DIRECT/INDIRECT PENDANT LIGHT FIXTURE WITH THREE 54W T5-HO LAMPS.
DUAL HEAD LED EGRESS FIXTURE WITH HIGH OUTPUT LIGHT HEADS.
MANUAL MOTOR STARTER SWTCH
MS
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
VAN
F
F
E
=
5
1
1
.0
0
STOP
STOP
SL1
SL1
UTILITY TRANSFORMER
SL1
SL1
TAG
FIXTURE DESCRIPTION
MOUNTING
SL1 POLE MOUNT
SITE LIGHT FIXTURE SCHEDULE
LAMPING
(1) 250W METAL
HALLIDE
METAL HALIDE POLE LIGHT 22-1/4"Lx30"Wx6-38"D, DIECAST ALUMINIUM HOUSING WITH
DARK BRONZE POWDER COAT FINISH. SUPER CWA PULSE START BALLAST, ROUND POLE
MOUNTING FIXTURE WITH 2-3\8" TENON MOUNTING SLIP FITTER FOR ONE
FIXTURE,ANODIZED REFLECTOR WITH TYPE THREE FORWARD TO THROW OPTICS WITH
SHARP CUTOFF. UL LISTED FOR WET ENVIRONMENT, 25' TALL POLE.
SL1
SL1
SL1 SL1 SL1
SL1SL1
1/16" = 1'-0"E100
1 SITE ELECTRICAL PLAN
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
HB
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
E
F
G
H
J
K
2019.21.8 8
HB
HB
HB
HB
X1
X1
X1
X1
X1
X1
F1
F1
F1
F1 F1
F1
F1
F1
F1 F1 F1
F1F1F1
F10
F10
F10F10
F10
F10F10
F4
F4
F4
F4
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5
F5F5
F6
F6
F6F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6
F6
F6
F6
F6
F6
F6
F6
F6
F7
F7
F7F7
F7
F7
F7
F7
F7
F7
F7F7
F8
F8F8
F8
F12F12
F12
F12F12
F12
F12 F12 F12
F12F12
F12
F12 F12
F12 F12
F12
F12
F13
F14
F14
F14
F14
F14
F14
F14
F14
F14
F14F14
F14
F14
F14
F14F14
F14
F14
F14
F14
F14
F14
F14
F14F14
F14
F14
F14
F15 F15 F15F15
F15
F15F15F15
F15
F15
F12F12
F12F12
F12F12
F12 F12
F12 F12
F18F18F18
F18
F18
F18
F18
F19
F19
F18
F18
F16
F12 F12
F2
F2F2
F2
F11
F11
F11
F3
F3
F3
F3
F14
X1
X1
X1
X1
X1
X1
X1
F9
F9
F9
F9F9
F9 F9
F9
F9
F16
F9
F9
F9
WOMENS
HALL
117
VESTIBULE
LIVING
ROOM
RECEPTION
RETAIL
SERVERY
PANTRY
WORK
ROOM
OFFICE
BREAK ROOM
MAINT
MEETING ROOM
STAIR A
FITNESS
QUEEN QUEEN QUEEN QUEEN
CORRIDORB
QUEEN QUEEN
POOL DECK
ACCESSIBLE
QUEEN
QUEEN
KING
SUITE
QUEEN QUEEN
KING
KING
SUITE
KING
KING
SUITE
ACCESSIBLE
KING
QUEEN QUEEN
STAIR B
QUEEN QUEEN
MECH
VERANDA
POOL EQUIP,
MECH
MEN
WOMEN
MENS
TELECOM
ELEC
CARTS
MECH
ELEVATOR
LOBBY
ICE
STORAGE A
ELEV EQUIP
ELEVATOR
STORAGE
B
BREAKFAST
LAUNDRY
CHUTE
GUEST
LAUNDRY
PORTE
COCHERE
CORRIDOR A
OFFICE
PO
OL A
CC
ES
S
CO
OR
ID
OR
STORAGE C
DEN/ BUSINESS
CENTER
QUEEN SUITE
100
101A
113A
114
112
109A
109B
109C
124B
103
ST-A1
140
119 121
138
123
143A
126
128
129
130
131
132
133
134
135
ST-B1
137
108
124A
141
142
105 107
118
110B
113C
110A
115
120
106
117B
139
117A
243
101B
104
109D
113B
104A
122
102
104B
116
127
X2X2X2X2X2X2
X1
X1
F14
F14 F14
F14F14
F14
F14
F14
F14
F14F14
F14
F14
F14
F14
F14
F14F14
F14
F14
F14
F14
F14
F20
F20
OS
L
OS L
OS L
OS L
OS
L
OS
L
OS
L
OS
L
OS
L
OS L
OS L
OS
L
X1
X2 X2
X1
CONTROLS F17
FIXTURES AT LIVING
ROOM CEILING
X2
X2
X1
X1
X2
X2
X1
X1
1a
1a
1a
1a
1b
1b
1b
1b
1b
1b
1c
1c
1c
1c
1e
1
1h
1d1d
1f
1a,b,c,d
1e
1f
1h
2a
2a
2b
2b
2b
2a
2c
2c
2d
2d
2d
2e
2e2e
2e2e
2f
2f2f
2f2f
2g,h
2g 2g
2g 2g
2g 2g
2h
2h
2h
2h2h2h
2h
3
3
3
3 3
3
3
3
4
44
4
4
4
4
4
44
4
4b
4a
4a
4b
4b
4b
4b
4b
5b
5a
5a
5a5a
5a
5b,c
5b
5b
5b
5b 5b
5c
5b
5b
5c
5c
5d
6a,b,c
6a
6a
6a
6a
6a 6a 6b
6b6a
6b 6b
6b
6b
6a
6c
6d,e,f
6d
6d
6d
6d
6d
e
6e
6e
6e
6e
6f
6f
7
7
7
7
7
7
7
77
7 7
7
7
7
7a
7a
8a,b
8a8a8a8a
8b8b
8c,d,e
8c8c
8c8c
8d8d8d8d
8d
8e 8e 8e 8e
8e
9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9
99
9
9
7
7
7
7
7b
7b
7
7
7
7
10 10 1010 10 10 10 10
10
10
10
11
11
11
1111
11
11
11
1111
11
111111
12
12
12
1212
12 12
12
12
12
12
12
12
12
12
12
12
12
12
12
13
1313
13
14
14
14
14
14
1414
2
2
6
6
1/8" = 1'-0"E211
1 LEVEL 1 LIGHTING PLAN
MA
TC
H LIN
E
SE
E S
HE
ET
E21
1A
MA
TC
H LIN
E
SE
E S
HE
ET
E211A
GENERAL NOTES:
1. ALL COMMON AREA LIGHTING CIRCUITS ORIGINATE ON PANEL P1A.
2. ALL GUEST ROOM CIRCUITS ORIGINATE ON PANEL P1B.
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. LIGHTING CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO
DETERMINE ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE LIGHTING CIRCUITS
TO PANEL P1A.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3
C
D
F
G
J
K
MEETING ROOM103
STAIR AST-A1
1.8
STORAGE A106
FEC
104LAUNDRY
CHUTE104A CORRIDOR A
102
OFFICE104B
0.7
G.1
G.9
0.30.5 0.20.6 0.4 0.1
F6
F6
F6
F6F6
F6
F6
F6
F6
F6
F6
F6
F6
F6
F6
F6
F6
F6
F6
F3F3
F6
F6
F6
F6
F4F4
F4
F4
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
F1 F1 F1 F1 F1
VESTIBULE
LOBBY
LOBBY
CONFERENCE A
CONFERENCEB
CONFERENCEC
WOMENS
MENS
KITCHEN
DISHWASHING
141
140
139
146
142
143
144A
144
145
CORRIDOR
138
147
F4F4
F10
F10
F10
F10
F14
F14
F14
F14
X1
X1
X1
X1
F14
F14
F14
F14
F14
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
X1
F10
F10
F20
F20
F6
F6
F10
F10
D
OS L OS L OS L
OS L OS L OS L
OS L OS L OS L
OS L OS L OS L
OS L OS L OS L
D
D
OS L
OS L
OS
L
OS
L
OS
L
OS
L
X1
X1
1
1
1 1
11 1
11
1
1 11 11
1 11 11
1 11 11
2 22 22
2 22 22
2 22 22
2 22 22
3 33 33
3 33 33
3 33 33
3 33 33
3 33 33
4 4
4 4
4
4
4 4
4 4
4 4
4 4
4 4
4
4
4
4
4
4
5b
5b
5b
5b
5b
5a
5a,b
5c
5c
5
5
5
5 5
5
55
5
5
5
5
5
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
5c
5a
MA
TC
H L
IN
E
SE
E S
HE
ET
E2
11
MA
TC
H L
IN
E
SE
E S
HE
ET
E2
11
1/8" = 1'-0"
E211A
1 LEVEL 1 LIGHTING - CONFERENCE
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. LIGHTING CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO
DETERMINE ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE LIGHTING CIRCUITS
TO PANEL P1A.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
112' - 1 3/8"
112' - 4 3/8"
112' - 1 3/8"
112' - 1 3/8"
112' - 7"
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
BB
CC
DD
EE
FF
GG
HH
JJ
2019.21.8
1/2" / 1'-0"
8
1
/4
"
/ 1
'-
0
"
1
/4
"
/ 1
'-
0
"
1
/
8
"
/
1
'-
0
"1
/
8
"
/
1
'-
0
"
112' - 2 9/16"
1/4
" / 1
'-0"
1/4
" / 1
'-0"
X1 X1
X1
X1
X1
F6 F6 F6 F6 F6 F6 F6 F6 F6F6 F6 F6
F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6 F6F6
F6
F6F6
F6
F6
F2
F2
F2
F2
F17
F6
F14
F14
ELEV
LOBBY
STAIR A
ST-A2
CORRIDOR
200
KING
SUITE
201
KING
WIDE
202
KING
SUITE
203
KING
204
KING
205
KING
206
KING
207
KING
208
KING
209
KING
SUITE
212
KING
SUITE
214
KING
218
219
KING
220
221
KING
222
223
KING
224
KING
SUITE
226
KING
SUITE
228
QUEEN QUEEN
229
QUEEN QUEEN
230
KING
SUITE
231
QUEEN QUEEN
232
KING
SUITE
233
ACCESSIBLE KING
234
QUEEN QUEEN
235
STAIR B
ST-B2
QUEEN QUEEN
237
KING
211
HOUSE KEEPING
236
KING
WIDE
216
KING
210
ICE
217
ELEVATOR
E-2
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
237
215
CORRIDOR
200
227
QUEEN SUITE
F17
F17
F17
X2 X2
X2
X2 X2 X2
OSL
F14
F14
X2
5d
5d
5d
5d
1 1 1 1 1
1
1 1 11 1 1
1 1 1 1 11
1 1 1 1 1 1 1 1 1 1 1 1
1
1
1
1
11
1
1
13
13
13
13
2 2
2
2 2 2
3
3
3
33
1/8" = 1'-0"E221
1 LEVEL 2 LIGHTING PLAN
PLAN NOTE:
1F17 FIXTURES CONTROLLED FROM RECEPTION 113B ON FIRST FLOOR. SEE SHEET E211.
1
1
1
1
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. LIGHTING CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO
DETERMINE ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE LIGHTING CIRCUITS
TO PANEL P2.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
X1 X1
X1
X1
X1
F2
F2
F2
F2
F6 F6 F6 F6 F6 F6
F6 F6 F6 F6 F6 F6F6
F6
F6F6
F6
F6F6
F6F6
F6 F6
F6F6 F6
F6F6
F6
F6
F6
F6
F14
F14
CORRIDOR
300
STAIR A
ST-A3
KING
SUITE
301
KING
SUITE
303
KING
304
KING
305
KING
306
KING
307
KING
308
KING
309
KING
310
KING
SUITE
312
KING
318
319
KING
320
321
KING
322
323
KING
324
KING
SUITE
326
KING
SUITE
328
329
330
KING
SUITE
331
332
KING
SUITE
333
ACCESSIBLE KING
334
QUEEN QUEEN
335
STAIR B
ST-B3
DOUBLE
QUEEN
337
KING
311
ACCESSIBLE KING
SUITE
313
KING
SUITE
315
HOUSE KEEPING
336
316
KING
SUITE
314
ELEVATOR
E-3
ICE
317
KING
WIDE
302
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN
QUEEN
QUEEN QUEEN
ELEV
LOBBY
315
CORRIDOR
300
327
QUEEN SUITE
KING
X2 X2 X2 X2 X2 X2
F14
F14
OS L
F6
X2
13
13
13
13
1 1 1 1 1 1 1 1 1
1
1
1 1
1 11 1
11
1 1 1
1
1 1
1
1
1
1
11
1
1
1
1
1
1
2 2 2 2 2 2
2
3
33
33
1/8" = 1'-0"E231
1 LEVEL 3 LIGHTING PLAN
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. LIGHTING CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO
DETERMINE ACTUAL CIRCUIT NUMBERS IN TEH FIELD. WIRE LIGHTING CIRCUITS
TO PANEL P3.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
HB
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
E
F
G
H
J
K
2019.21.8 8
RE
F
RE
F
DW
RE
F
FECFEC
FECFEC
FE
C
HB
HB
HB
HB
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
WP
GFCI
WP
GFCI
WP
GFCI
GFCI
WP
GFCI
WP
TV
GFCI
GFCI
TV
GFCI
GFCI
REF
MICROWAVE
REF
REF
GFCI
GFCI
GFCI
WOMENS
HALL
117
VESTIBULE
LIVING
ROOM
RECEPTION
RETAIL
SERVERY
PANTRY
WORK
ROOM
OFFICE
BREAK ROOM
MAINT
MEETING ROOM
STAIRA
FITNESS
QUEEN QUEEN QUEEN QUEEN
CORRIDORB
QUEEN QUEEN
POOL DECK
ACCESSIBLE
QUEEN
QUEEN
KING
SUITE
QUEEN QUEEN
KING
KING
SUITE
KING
KING
SUITE
ACCESSIBLE
KING
QUEEN QUEEN
STAIR B
QUEEN QUEEN
MECH
VERANDA
POOL EQUIP,
MECH
MEN
WOMEN
MENS
TELECOM
ELEC
CARTS
MECH
ELEVATOR
LOBBY
ICE
STORAGE
A
ELEV EQUIP
ELEVATOR
STORAGE
B
BREAKFAST
LAUNDRY
CHUTE
GUEST
LAUNDRY
PORTE
COCHERE
CORRIDOR A
OFFICE
PO
OL A
CC
ES
S
CO
OR
ID
OR
STORAGE C
DEN/
BUSINESS
CENTER
QUEEN SUITE
100
101A
113A
114
112
109A
109B
109C
124B
103
ST-A1
140
119 121
138
123
143A
126
128
129
130
131
132
133
134
135
ST-B1
137
108
124A
141
142
105 107
118
110B
113C
110A
115
120
106
117B
139
117A
243
101B
104
109D
113B
104A
122
102
104B
116
127
PROVIDE 20A/2P CB
WITH GROUND FAULT
PROTECTION.
208V
PROVIDE 20A/2P CB
WITH GROUND FAULT
PROTECTION.
42"
42"
SP-1
MAIN
DIST.
METER
P1A
P1B
CONCRETE
EQUIPMENT PAD.
FACP
FCU-1-01
FCU-1-08
FCU-1-09
FCU-1-10
FCU-1-02
FCU-1-07
FCU-1-03
FCU-1-06
FCU-1-05
FCU-1-04
ELEVATOR CAR
LIGHTING IS 30A/2P
ELEVATOR
CONTROLLER
100A/3P NON-FUSED
TMV-1
DHW-1,2,3
DP1
DP2
MS
MS
MS
MS
MS
MS
MS
MS
MS
MS
P1A:31
P1A:33
P1A:35
P1A:36
P1A:37
P1A:38
P1A:40
P1A:39
P1A:15
P1A:16
P1A:17P1A:19,21
P1A:24,26
P1A:16
P1A:18,20
P1A:20
P1A:23
P1A:25
P1A:28
P1A:27
P1A:29
P1A:30
GFCI
WP
P1A:32
P1A:40,42
P1A:44,46
GFCI
P1A:34
P1A:39,41 P1A:43,45
GFCI
WP
P1A:48
P1A:50
P1A:52
P1A:54
P1A:47GFCI
P1A:49
P1A:51,53
P1A:55
P1A:57
P1A:56 P1A:58
DP2:25,27
DP2:25,27
DP2:26,28
DP2:26,28
DP2:26,28
DP2:27,29
DP2:27,29
DP2:30,32
DP2:30,32
DP2:30,32
MSB
P1A:60
1/8" = 1'-0"E311
1 LEVEL 1 POWER PLAN
MA
TC
H LIN
E
SE
E S
HE
ET
E3
11A
MA
TC
H LIN
E
SE
E S
HE
ET
E311A
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3
C
D
F
G
J
K
MEETING ROOM103
STAIR AST-A1
1.8
STORAGE A106
FEC
104LAUNDRY
CHUTE104A CORRIDOR A
102
OFFICE104B
0.7
G.1
G.9
0.30.5 0.20.6 0.4 0.1
GFCIGFCI
VESTIBULE
LOBBY
LOBBY
CONFERENCE A
CONFERENCEB
CONFERENCE C
WOMENS
MENS
KITCHEN
DISHWASHING
141
140
139146
142
143
144A
144
145
CORRIDOR
138
147
E501
1
AC-1
FCU-1A-03
FCU-1A-02
FCU-1A-03
FCU-1A-04
FCU-1A-05
J
J
J
J
MS
MS
MS
P1A:14
P1A:15
DP2:1
P1A:16
P1A:17 P1A:18
DP2:2,4
P1A:19
MS
MS
DP2:6,8
DP2:5,7
MA
TC
H L
IN
E
SE
E S
HE
ET
E3
11
MA
TC
H L
IN
E
SE
E S
HE
ET
E3
11
1/8" = 1'-0"
E311A
1 LEVEL 1 POWER - CONFERENCE
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
112' - 1 3/8"
112' - 4 3/8"
112' - 1 3/8"
112' - 1 3/8"
112' - 7"
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
BB
CC
DD
EE
FF
GG
HH
JJ
2019.21.8
1/2" / 1'-0"
8
1
/4
"
/ 1
'-
0
"
1
/4
"
/ 1
'-
0
"
1
/
8
"
/
1
'-
0
"
1
/
8
"
/
1
'-
0
"
112' - 2 9/16"
1/4" / 1'-0"
1/4" / 1'-0"
ELEV
LOBBY
STAIR A
ST-A2
CORRIDOR
200
KING
SUITE
201
KING
WIDE
202
KING
SUITE
203
KING
204
KING
205
KING
206
KING
207
KING
208
KING
209
KING
SUITE
212
KING
SUITE
214
KING
218
219
KING
220
221
KING
222
223
KING
224
KING
SUITE
226
KING
SUITE
228
QUEEN QUEEN
229
QUEEN QUEEN
230
KING
SUITE
231
QUEEN QUEEN
232
KING
SUITE
233
ACCESSIBLE KING
234
QUEEN QUEEN
235
STAIR B
ST-B2
QUEEN QUEEN
237
KING
211
HOUSE KEEPING
236
KING
WIDE
216
KING
210
ICE
217
ELEVATOR
E-2
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
237
215
CORRIDOR
200
227
QUEEN SUITE
GFCI
P2:4
P2:5
P2
P2B
1/8" = 1'-0"E321
1 LEVEL 2 POWER PLAN
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
P2.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
CORRIDOR
300
STAIR A
ST-A3
KING
SUITE
301
KING
SUITE
303
KING
304
KING
305
KING
306
KING
307
KING
308
KING
309
KING
310
KING
SUITE
312
KING
318
319
KING
320
321
KING
322
323
KING
324
KING
SUITE
326
KING
SUITE
328
329
330
KING
SUITE
331
332
KING
SUITE
333
ACCESSIBLE KING
334
QUEEN QUEEN
335
STAIR B
ST-B3
DOUBLE
QUEEN
337
KING
311
ACCESSIBLE KING
SUITE
313
KING
SUITE
315
HOUSE KEEPING
336
316
KING
SUITE
314
ELEVATOR
E-3
ICE
317
KING
WIDE
302
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN
QUEEN
QUEEN QUEEN
ELEV
LOBBY
315
CORRIDOR
300
327
QUEEN SUITE
KING
GFCI
P3:4
P3:5
P3
P3-B
1/8" = 1'-0"E331
1 LEVEL 3 POWER PLAN
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
P3.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
LINEN CHUTE
VENT
FIREPLACE
VENT
ERV-2
APPROX WEIGHT:
2500 lbs
30x14 SA DN
32x14 EA DN
TEF-1
300 CFM
TEF-1
150 CFM
TEF-1
300 CFM
TEF-1
300 CFM
TEF-1
450 CFM
TEF-1
300 CFM
TEF-1
150 CFM
TEF-1
200 CFM
TEF-1
200 CFM
TEF-1
300 CFM
TEF-1
100 CFM
TEF-1
100 CFM
TEF-1
200 CFM
TEF-1
100 CFM
TEF-1
100 CFM
TEF-1
200 CFM
TEF-1
100 CFM
TEF-1
200 CFM
TEF-1
100 CFM
TEF-1
200 CFM
GFCI
WP
P3:6
P3:7-9
P3:6-8
P3:11-13
P3:10-12
P3:15-17
DP2:1-3
1/8" = 1'-0"E341
1 ROOF POWER PLAN
PLAN NOTE:
1EQUIPMENT FURNISHED WITH INTEGRAL DISCONNECT SWITCH.
PROVIDE 45A/3P CIRCUIT BREAKER IN PANEL INDICATED.2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
RIN
EEREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1/4
" / 1
'-0
"
1/4
" / 1
'-0
"
1/4" / 1'-0"
1/4
" / 1'-0
"
1/4" / 1'-0"
1/4
" / 1
'-0
"1
/4
" / 1
'-0
"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/8
" / 1
'-0
"
C
D
F
G
J
K
0.7
G.1
G.9
0.30.5 0.20.6 0.4 1 0.1
1/4" / 1
'-0
"1/4
" / 1'-0
"
1/4" / 1'-0"
1/4
" / 1
'-0
"
1/4
" / 1
'-0
"
1/4" / 1
'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4
" / 1
'-0
"1
/4
" / 1
'-0
"1
/8
" / 1'-0
"1
/4
" / 1
'-0
"1/4
" / 1'-0
"
K-MAU-1
KEF-1
ACCU-1 ACCU-2
DEF-1
SCU-1
GFCI
WP
DP2:2-4
DP2:5-7-9
DP2:6-8-10
DP2:11-13-15
DP2:12-14
DP2:16-18
DP2:17-19
DP2:20-22-24
P1A:61
ERV-1
GFCI
WP
P1A:61
1/8" = 1'-0"E341A
1 ROOF PLAN - CONFERENCE
MA
TC
H L
IN
E
SE
E E
34
1
MA
TC
H L
IN
E
SE
E E
34
1
PLAN NOTE:
1EQUIPMENT FURNISHED WITH INTEGRAL DISCONNECT SWITCH.
PROVIDE 60A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 40A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 30A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 20A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 100A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 70A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 60A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 35A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 60A/3P NEMA 3R NON-FUSED DISCONNECT SWITCH. PROVIDE 50A/3P CIRCUIT
BREAKER IN PANEL INDICATED.
PROVIDE 35A/3P CIRCUIT BREAKER IN PANEL INDICATED.
2
3
4
5
6
1
1
2
3
4
5
6
7
1
7
GENERAL NOTES:
1. SEE SHEET E500 FOR GUEST ROOM ENLARGED PLANS.
2. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
HB
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
E
F
G
H
J
K
2019.21.8 8
HB
HB
HB
HB
SD
MH
HH
SD SD SD SDSD SD
ER
SD SD SDSDSD
SD
ER
M
V
FAAP
V
V
V
FACP
SD
V
H
M
M
VV
H
H
SD
SD
H
WP
V
WOMENS
HALL
117
VESTIBULE
LIVING
ROOM
RECEPTION
RETAIL
SERVERY
PANTRY
WORK
ROOM
OFFICE
BREAK ROOM
MAINT
MEETING ROOM
STAIR
FITNESS
QUEEN QUEEN QUEEN QUEEN
CORRIDORB
QUEEN QUEEN
POOL DECK
ACCESSIBLE
QUEEN
QUEEN
KING
SUITE
QUEEN QUEEN
KING
KING
SUITE
KING
KING
SUITE
ACCESSIBLE
KING
QUEEN QUEEN
STAIR B
QUEEN QUEEN
MECH
VERANDA
POOL EQUIP,
MECH
MEN
WOMEN
MENS
TELECOM
ELEC
CARTS
MECH
ELEVATOR
LOBBY
ICE
STORAGE A
ELEV EQUIP
ELEVATOR
STORAGE
B
BREAKFAST
LAUNDRY
CHUTE
GUEST
LAUNDRY
PORTE
COCHERE
CORRIDOR A
OFFICE
PO
OL A
CC
ES
S
CO
OR
ID
OR
STORAGE C
DEN/
BUSINESS
CENTER
QUEEN SUITE
100
101A
113A
114
112
109A
109B
109C
124B
103
ST-A1
140
119 121
138
123
143A
126
128
129
130
131
132
133
134
135
ST-B1
137
108
124A
141
142
105 107
118
110B
113C
110A
115
120
106
117B
139
117A
243
101B
104
109D
113B
104A
122
102
104B
116
127
FSTS
FSTS
A
V
V
H
V
H
V
H
V
H
H
H H H
V
V
V
H
WP
H
WP
H
WP
V
MM
HD
AR
HDSD
ER
1/8" = 1'-0"E411
1 LEVEL 1 SYSTEMS PLAN
MA
TC
H LIN
E
SE
E S
HE
ET
E41
1A
MA
TC
H LIN
E
SE
E S
HE
ET
E411A
PLAN NOTE:
1PROGRAM FIRE ALARM SYSTEM TO SHUNT TRIP THE ELEVATOR BREAKER WHEN THE
HEAT DETECTOR IS ACTIVATED.
1
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3
C
D
F
G
J
K
MEETING ROOM103
STAIR AST-A1
1.8
STORAGE A106
FEC
104LAUNDRY
CHUTE104A CORRIDOR A
102
OFFICE104B
0.7
G.1
G.9
0.30.5 0.20.6 0.4 0.1
V
V
H
M
M
M
M
H
M
M
HH
H
HH
VESTIBULE
LOBBY
LOBBY
CONFERENCE A
CONFERENCEB
CONFERENCEC
WOMENS
MENS
KITCHEN
DISHWASHING
141
140
139146
142
143
144A
144
145
CORRIDOR
138
147
M
V
HH
H
V
VM
H
AR
MA
TC
H L
IN
E
SE
E S
HE
ET
E4
11
MA
TC
H L
IN
E
SE
E S
HE
ET
E4
11
1/8" = 1'-0"
E411A
1 LEVEL 1 SYSTEM - CONFERENCE
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
112' - 1 3/8"
112' - 4 3/8"
112' - 1 3/8"
112' - 1 3/8"
112' - 7"
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
BB
CC
DD
EE
FF
GG
HH
JJ
2019.21.8
1/2" / 1'-0"
8
1
/4
"
/ 1
'-
0
"
1
/4
"
/ 1
'-
0
"
1
/
8
"
/
1
'-
0
"
1
/
8
"
/
1
'-
0
"
112' - 2 9/16"
1/4" / 1'-0"
1/4" / 1'-0"
M
SD
MH HH
SD SD SD SDSD
SD
ER
SD SD SDSDSD
ELEV
LOBBY
STAIR A
ST-A2
CORRIDOR
200
KING
SUITE
201
KING
WIDE
202
KING
SUITE
203
KING
204
KING
205
KING
206
KING
207
KING
208
KING
209
KING
SUITE
212
KING
SUITE
214
KING
218
219
KING
220
221
KING
222
223
KING
224
KING
SUITE
226
KING
SUITE
228
QUEEN QUEEN
229
QUEEN QUEEN
230
KING
SUITE
231
QUEEN QUEEN
232
KING
SUITE
233
ACCESSIBLE KING
234
QUEEN QUEEN
235
STAIR B
ST-B2
QUEEN QUEEN
237
KING
211
HOUSE KEEPING
236
KING
WIDE
216
KING
210
ICE
217
ELEVATOR
E-2
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
237
215
CORRIDOR
200
227
QUEEN SUITE
FS TS
H H HH
V
SD
1/8" = 1'-0"E421
1 LEVEL 2 SYSTEMS PLAN
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
1 2 3 4 5 6 7 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
J
2019.21.8 8
M
M
SD SD SD SD SDSD SD
ER
SD SD
SD
SDSD
H HH
CORRIDOR
300
STAIR A
ST-A3
KING
SUITE
301
KING
SUITE
303
KING
304
KING
305
KING
306
KING
307
KING
308
KING
309
KING
310
KING
SUITE
312
KING
318
319
KING
320
321
KING
322
323
KING
324
KING
SUITE
326
KING
SUITE
328
329
330
KING
SUITE
331
332
KING
SUITE
333
ACCESSIBLE KING
334
QUEEN QUEEN
335
STAIR B
ST-B3
DOUBLE
QUEEN
337
KING
311
ACCESSIBLE KING
SUITE
313
KING
SUITE
315
HOUSE KEEPING
336
316
KING
SUITE
314
ELEVATOR
E-3
ICE
317
KING
WIDE
302
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN QUEEN
QUEEN
QUEEN
QUEEN QUEEN
ELEV
LOBBY
315
CORRIDOR
300
327
QUEEN SUITE
KING
FS TS
H H HH
V
SD
HD
1/8" = 1'-0"E431
1 LEVEL 3 SYSTEMS PLAN
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
42"
SD
34"
34"
GFCI
R2
R2
26"
26"
R1
R3
R4
34"
34"
42"
26"
26"
SD
GFCI
R2
R2
R1
R3
R4
GFCI
R2
R2
R1
R1
R3
R4
V
34"
34"
42"
26"
26"
V
V
SD
42"
R3
R3
R3
R3
R3
R3
R1
R1
R1
R2
R2
R2
R2
R2
R2
GFCI
R2
R2 R4
R4
R4
R4
42"
42"
42"
42"
26"
26"
26"
26"
26"
26"
26"
26"
34"
34"
34"
34"
34"
34"
34"
34"
V
V
V
V
SD
SD
SD
SD
GFCI
GFCI
GFCI
56"
42"
42"
42"
42"
42"
42"
42"
56"
PTAC PTAC
VTAC
VTAC
VTAC
PTAC
PTAC
a
CKT-1,3
F20
CKT-2
CKT-4
a
a,b
a
b
a
b
b
M
M
F20
CKT-1,3
b
b
b
a
a
a
CKT-4
CKT-2
F20
CKT-1,3
CKT-4
CKT-2
a,b
a
a
a
a
a
a,b
b
b
F20
CKT-1,3
CKT-1,3
F20
CKT-1,3
F20
M
CKT-1,3F20
CKT-2
a,b
CKT-2
a,b
CKT-2
a,b
CKT-2
CKT-4
a
a
b
a,b
b
b
b
a
b
42"
b
a
a
a b
a
b
CKT-4
CKT-4
a
b
a
a
b
a
b
CKT-4
b
b
b
a
a
a
a
b
209
KING
QUEEN QUEEN
KING SUITE
ACCESSIBLE KING
ACCESSIBLE QUEEN QUEEN
ACCESSIBLE KING SUITE
KING SUITE
1/4" = 1'-0"E500
2 QUEEN QUEEN
1/4" = 1'-0"E500
1 KING
1/4" = 1'-0"E500
3 KING SUITE
1/4" = 1'-0"E500
3 ACCESSIBLE KING GUESTROOM
1/4" = 1'-0"E500
5 ACCESSIBLE QUEEN QUEEN
1/4" = 1'-0"E500
6 ACCESSIBLE KING SUITE
1/4" = 1'-0"E500
7 KING SUITE ALTERNATE
GENERAL NOTE:
1
1. FOR ELECTRICAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES, SEE SHEET E001.
2. SEE LIGHTING FIXTURE SCHEDULE ON SHEET E600.
3. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF
LIGHTING FIXTURES.
4. ALL RECEPTACLE SHALL BE MOUNTED AT +18" AFF UNLESS NOTED OTHERWISE.
5. FIRE ALARM VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS TO THE AUTHORITY
HAVING JURISDICTION FOR REVIEW AND APPROVAL. FIRE ALARM VENDOR TO INCLUDE
ANY ADDITIONAL DEVICES TO PROVIDE A FULLY FUNCTIONAL SYSTEM.
6. COORDINATE ALL DEVICE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH IN.
7. PROVIDE SMOKE DETECTOR WITH SOUNDER BASE IN EACH ROOM ON THIS SHEET.
SMOKE DETECTOR SHALL ACTIVATE SOUNDER BASE AND STROBES WITHIN THE ROOM
ONLY AND INDICATE A SUPERVISORY SIGNAL ON THE FACP. SOUNDER BASE AND
STROBES WILL ACTIVATE.
8. ALL RECEPTACLES IN GUEST ROOM UNITS SHALL BE TAMPER RESISTANT.
9. ALL SLEEPING ROOMS WILL HAVE A VISUAL DEVICE. ONLY ACCESSIBLE ROOMS WILL
HAVE A VISUAL DEVICE IN THE BATHROOM.
10. GUESTROOM BATHROOMS SHALL HAVE DEDICATED CIRCUIT SERVING GFCI
RECEPTACLE.
11. ALL GUESTROOMS SHALL HAVE A MASTER ROCKER SWITCH AT ENTRY LABELED
"MASTER SWITCH" TO CONTROL HARD WIRED FIXTURES AND SWITCHED OUTLETS.
12. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE ACTUAL
CIRCUIT NUMBERS IN THE FIELD. WIRE GUEST ROOM CIRCUITS TO THE FOLLOWING
PANELS:
FIRST FLOOR P1A
SECOND FLOOR : P2 AND P2B
THIRD FLOOR: P3 AND P3B.
PLAN NOTE:
1DESK OPTION 1 (2 - OUTLETS / 1 - USB), DESK OPTION 2 (2 - OUTLETS / 1 - DATA)
2KING HEADBOARD - OPTION 1 (2 - OUTLETS / 1 - USB), QUEEN QUEEN HEADBOARD -
OPTION 1 (2 - OUTLETS / 1 - USB)
2
2
1
1
1
1
1
1
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
REF.
1
J
K
0.2 0.1
144KITCHEN
144ADISHWASHING
GFCI
GFCI
GFCI
GFCI
GFCIGFCI
DISH WASHING
ICE MAKER-15A/120V
COFFEE MAKER-12A/120V
MICROWAVE-1500VA/120V
TOASTER-12A/120V
J
20KW/208V/3PH
COOLER-15A/120V
COOLER-15A/120V
REF-9A/120V
WAFFEL MAKER
15A/120V
12A/120V
P1A:20
P1A:21
P1A:22
P1A:23
P1A:24
SLICER
10A/120V
P1A:25
P1A:26
P1A:27 P1A:28
P1A:29
P1A:30,32,34
CAN OPENER-180VA/120V
1/4" = 1'-0"
E501
1 ENLARGED ELECTRICAL KITHCEN AREA PLAN
1
PLAN NOTE:
1PROVIDE SHUNT TRIP ON THE CIRCUIT BREAKER AND WIRE THE SHUNT TRIP CIRCUIT
THROUGH THE HOOD SUPRESSION SYSTEM.
GENERAL NOTES:
1. CIRCUIT NUMBERS SHOWN FOR COUNT ONLY. CONTRACTOR TO DETERMINE
ACTUAL CIRCUIT NUMBERS IN THE FIELD. WIRE RECEPTACLE CIRCUITS TO PANEL
INDICATED.
32
00 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, IL
LIN
OIS
, 62
71
1
Pho
ne: (21
7) 793
-229
9
Fax: (21
7) 79
3-33
11
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L ENG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
TAG
FIXTURE DESCRIPTION
MOUNTING
F1 SUSPENDED 2x4 DIRECT/INDIRECT PENDANT LIGHT FIXTURE WITH THREE 54W T5-HO LAMPS.
F2 WALL INTERIOR SCONCE WITH 42W CFL LAMP AND BATTERY PACK.
F3 WALL INTERIOR SCONCE WITH 10W LED LAMP
F4 DECORATIVE SURFACE FIXTURE WITH TWO 13W CFL LAMPS.
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
X2
1x4 SURFACE LIGHT FIXTURE WITH TWO 32W T8 LAMPS.
RECESSED RECESSED FIXTURE WITH 1000 LUMEN LED.
RECESSED RECESSED FIXTURE WITH 1300 LUMEN LED.
SUSPENDED PENDANT FIXTURE WITH 42W CFL LAMP.
RECESSED RECESSED FIXTURE WITH 1000 LUMEN LED.
EXTERIOR SCONCE WITH 18W CFL LAMP AND BATTERY PACK.WALL
RECESSED FIXTURE WITH 13W CFL LAMP.
DECORATIVE PENDANT FIXTURE WITH FOUR 9W LED LAMPS.SUSPENDED
SQUARE RECESSED FIXTURE WITH 1000 LUMEN LED LAMP.RECESSED
1x4 SURFACE LIGHT FIXTURE WITH TWO 32W T8 LAMPS PER FOUR FOOT SECTION.CEILING
1x4 45W LED SURFACE LIGHT FIXTURE.CEILING
RECESSED WET RATED SHOWER FIXTURE WITH 1000 LUMEN LED.
RECTANGULAR DOWN LIGHT WITH THREE HEADS HAVING ONE 18W CFL LAMP EACH.
RECESSED FIXTURE WITH 13W CFL LAMP.
RECESSED
RECESSED
RECESSED
DECORATIVE SCONCE WITH TWO 18W CFL LAMPS.WALL
DUAL HEAD LED EGRESS FIXTURE WITH HIGH OUTPUT LIGHT HEADS.WALL
LIGHT FIXTURE SCHEDULE
TAG
FIXTURE DESCRIPTION
MOUNTING
R1 CEILING DECORATIVE ENTRY FIXTURE WITH THREE 13W CFL LAMPS.
R2 WALL VANITY FIXTURE WITH 13W CFL LAMP.
R3 RECESSED RECESSED WET RATED SHOWER FIXTURE WITH 1000 LUMEN LED.
R4 CEILING 12V LED SURFACE PUCK FIXTURE WITH REQUIRED ACCESSORIES.
GUESTROOM LIGHT FIXTURE SCHEDULE
REMARKS
PROVIDE BATTERY CAPABLE OF ILLUMINATING ONE LAMP
FOR 90 MINUTES WHERE INDICATED ON FLOOR PLANS
CEILING
CEILING
RECESSED
CEILING/WALL LED EXIT FIXTURE - SINGLE OR DOUBLE FACE WITH AROWS AS INDICATED ON PLAN.X1
F20 85W LED COVE LIGHT FIXTURE.WALL
F21 17W LED WALL PACK FIXTURE WITH INTEGRAL BATTERY PACKWALL
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015
UTILITY TRANSFORMER. EC TO
PROVIDE TRANSFORMER BASE
AND GROUNDING PER UTILITY
COMPANY.
MSB
UTILITY POWER POLE.
LOCATION TO BE
DETERMINED.
P3
P2
P1A
P1B
EQUIPMENT
GROUND
CONDUIT SIZE AND QUANTITY
2-1/2"
1/0
F2000 500
F900
F1600
F1200
F1000
350
500
350
500
250
2/0
2/0
3/0
4/0
F450 4/0
F800
F500
F600
F700
350
350
500
250
F250
F300
F350
F400
500
350
250
2
1
1/0
2
4
3
4
(3) 3"(3) 2-1/2"
(6) 3"
(4) 2-1/2"
(3) 2-1/2"
(5) 3"
(3) 3"
(6) 3-1/2"
(4) 3"
(5) 3"
(3) 3"
(3) 3"
(2) 2"
(2) 2-1/2"
(2) 3"
(2) 2"
2"
2"
3"
2-1/2"
2"
(2) 2-1/2"
(2) 3"
(2) 3"
(2) 2-1/2"
3"
2-1/2"
3"
1-1/4"
1-1/4"
1-1/4"
1-1/2"
1-1/4"
FEEDER SCHEDULE
F60 106
F150
F175
F225
F200 3/0
4/0
1/0
2/0
F125
F110
F90 & F100
F70 & F80
3
2
1
4
6
6
6
4
8
6
6
8
NEUTRAL
PHASE AND
CONDUCTOR PER CONDUIT
F30
F20
F40 & F50
10
8
12
FEEDER
10
10
12
OR
1"3/4" 3/4"
1-1/4"
2"
2"
1-1/2"
1-1/2"
1"
1"
3/4"
1"
1-1/4"
1"
1-1/2"
2-1/2"
2"
2"
1-1/2"
1-1/4"
1-1/4"
1-1/4"
2P, 1N, 1G1P, 1N, 1G
3/4"
3/4"
2P, 1G
3/4"
3/4"
3/4"
3P, 1G
OR
3/4"
3P, 1N, 1G
3/4"
3/4"
3/4"
(3) 3-1/2"
(6) 4"
(4) 3-1/2"
(3) 3-1/2"
(5) 4"
(3) 4"
(2) 3"
(2) 3"
(2) 3-1/2"
(2) 4"
3"
4"
3-1/2"
1"
2"
2"
2-1/2"
2-1/2"
2-1/2"
1-1/2"
1-1/2"
1-1/4"
3P, 3N, 1G
1"
3/4"
3/4"
2-1/2"500 3
3" 3" 4"
-
-
-
-
-
-
-
-
-
-
DP2
F400
F400
F400
F400
F3000
DESIGNATION
TO BUILDING
GROUND SYSTEM.
3/0 COPPER GROUND IN
3/4" CONDUIT. SEE
GROUNDING RISER DETAIL
THIS SHEET.
F1200
#3/0 BARE COPPER IN 1" SCHEDULE 40 PVC
CONDUIT TO DRIVEN GROUND FIELD.
GROUND BUS LOCATED IN MAIN
SWITCHBOARD "MSB".
#3/0 AWG IN 3/4" CONDUIT FROM
WATER SERVICE.
#4 AWG IN3/4" PVC CONDUIT FROM REBAR
LOCATED IN THE BOTTOM OF FOUNDATION
FOOTINGS.
PROVIDE #3/0 BARE SOLID COPPER
CONDUCTOR BETWEEN GROUND RODS AND
ATTACH WITH EXOTHERMIC WELDED
CONNECTIONS 6" BELOW TOP OF RODS.
INSTALL GROUND FIELD IN THE NEAREST AVAILABLE
EXTERIOR UNPAVED AREA PER THE REQUIREMENTS OF
N.E.C. ARTICLE 250. RECORD INSTALLED LOCATION ON
CONSTRUCTION RECORD DOCUMENTS.
#3/0 BARE COPPER CONDUCTOR FROM MAIN
GROUND BUS. ATTACH WITH BOLTED CONNECTION
IN TEST WELL.
TYPICAL - 3/4" X 10'-0" COPPERWELD GROUND ROD DRIVEN IN
10'-0" EQUILATERAL TRIANGLE. GROUND FIELD SHALL BE A
MINIMUM OF 2'-0" AWAY FROM THE BUILDING.
EC TO PROVIDE CONDUITS PER UTILITY COMPANY.
F400
HOUSEKEEPING PAD
INTEGRAL
POWER METER
SURGE SUPPRESSION
DEVICE
TO PIPING SYSTEMS REQUIRED BY CODE TO BE
BONDED SUCH AS GAS, DUCT WORK, STORM, ETC.
IN ACCORDANCE WITH NATIONAL ELECTRIC CODE
250.104(B).
F3000 500 250(9) 3" (9) 3-1/2" (9) 4"
-
UTILITY REVENUE
METER
400A
/3P
400A
/3P
400A
/3P
400A
/3P
1200A
/3P
400A
/3P
100A
/3P
3000A
/3P
FURNISH MSB WITH AIC RATING OF 65K
300A
/3P
300A
/3P
300A
/3P
1200A
/3P
WA
TE
R H
EA
TE
R-1
WA
TE
R H
EA
TE
R-2
WA
TE
R H
EA
TE
R-3
DP1
F300 F300 F300
LP1
F100
100A
/3P
F100
POOL
TO BE DESIGNED BUILD
UNDER OTHER PERMIT.
ELEVATOR
100A
/3P
ELEVATOR CONTROLLER
PROVIDE CIRCUIT BRAEKER WITH
24V SHUNT TRIP AND CONNECT FOR
FIRE ALARM SYSTEM CONTROL.
P3B
PROVIDE CIRCUIT BREAKER WITH
24V SHUNT TRIP AND WIRE TO FIRE
ALARM SYSTEM THROUGH
ADDRESSABLE RELAY.
F70
P2B
NTSE700
1 NORMAL POWER RISER DIAGRAM
NTSE700
2 GROUNDING RISER DIAGRAM
NTSE700
3 GROUND FIELD DIAGRAM
320
0 P
LE
AS
AN
T R
UN
, S
UIT
E A
SP
RIN
GF
IE
LD
, ILL
IN
OIS
, 627
11
Phon
e: (2
17) 7
93-2
299
Fa
x: (217
) 7
93
-331
1
ww
w.trcw
w.com
ROBERT A. BOELLNER
STATE OF TEXAS
PR
OFESSION A L E NG
R
INE
EREGIS
D
T E RE
EXPIRES: 06-30-2016
SIGNED: 12-14-2015