07.05.2009 Christian Dersch 2
What is Solargeo?
Solargeo is a system which saves energy and investment costs forheating and domestic water production
This is possible to combine with an optimazation of the system components:
Geothermic and Solar.
The System components based on the following products:-Solar system for energy delivery-Storage unit for direct using of the solar energy-Brine/Water Heat pump-Geothermic storage and transfer unit-Regulation- and hydraulic unit
Eco-energy technicRoth Solargeo
07.05.2009 Christian Dersch 3
Eco-energy technicRoth Solargeo
Roth energy system – 5 Roth components fit together
07.05.2009 Christian Dersch 4
Roth Solar collector Heliostar+:
For using in combination with deep temperature, special construction
• Special sealing for solar glass,
• Special connections for the absorber pipe (supply/return)
• Special material configuration
Target:
•Stopping of condensation
•Stopping from corrosion inside of the collector
The number of the collectors depends on the project size
Eco-energy technicRoth Solargeo
07.05.2009 Christian Dersch 5
Roth Solar collector Heliostar+:
Eco-energy technicRoth Solargeo
standard
Condensation: Due to the formation of condensation water, all componentsmust be corrosion - resistant.
07.05.2009 Christian Dersch 6
Hot water storage for domestic use and heating –Roth stratified storage tank 800 / 1000 liter
Eco-energy technicRoth Solargeo
07.05.2009 Christian Dersch 7
Roth Heat pump TerraCompact: • Power sizes of Roth Heat pumps: TerraCompact 6 – 12 kW.
Eco-energy technicRoth Solargeo
07.05.2009 Christian Dersch 9
Roth Solargeo register station
Eco-energy technicRoth Solargeo
•Cabinet installed in the ground for hydraulicconnection between solar and geothermicregister
•Consisting of:- Plastic case with walkable
cover(diameter ca. 1,2 m).
- Manifold (4-24 leavings)
• Manifold (1“ or 1 ½“) for supply and returnconnection of the register elments
With fill and drain device as well as manual vent
07.05.2009 Christian Dersch 10
Roth Solargeo register station
Eco-energy technicRoth Solargeo
factory-made pre assembled as register packagewith 2 x 60 m pipe. Register pipes fixed in selected installing distanceby using solid plastic fixing elements.
System pipe:Roth PE-System pipe 20 mmwithout oxygen barrier.
Register dimensions:Length: 5 m with direction change (10 m)Height: 1,10 m pipe distance: 0,1 mquantity of pipe: 120 m/Register
plastic fixing element:- Positioning / fixation of register in the
collector trench- 9 pcs./register
07.05.2009 Christian Dersch 11
Roth Solargeo register
Eco-energy technicRoth Solargeo
Earthworks: The loops can be arranged in individual trenches
07.05.2009 Christian Dersch 15
Eco-energy technicRoth Solargeo
Schematic diagramQs
solar radiation
storage charging
07.05.2009 Christian Dersch 16
Eco-energy technicRoth Solargeo
Schematic diagramQs
solar radiation
storage charging
07.05.2009 Christian Dersch 17
Eco-energy technicRoth Solargeo
Schematic diagramQs
solar radiation
storage charging
07.05.2009 Christian Dersch 18
Eco-energy technicRoth Solargeo
Schematic diagramQs
solar radiation
storage charging
07.05.2009 Christian Dersch 19
Eco-energy technicRoth Solargeo
Schematic diagramQs
solar radiation
Demand of the
Heat pump
07.05.2009 Christian Dersch 20
Eco-energy technicRoth Solargeo
Schematic diagramQs
solar radiation
storage chargedno demand of theHeat pump
07.05.2009 Christian Dersch 21
Performance dataHeat pump SW 10
empf. Volumenstrom Heizung: 2 m³/hempf. Volumenstrom Quelle: 2,8 m³/h
Kältemittel: R 407CKältemittelinhalt: 1,8 kg
supply temp. 35 40 45 50 35 40 45 50 35 40 45 50 35 40 45 50 35 40 45 50in °C
source temp. heat output in kW power consumption in kW performance number refrigeration capacity in kW charging rate in Ain °C
-5 9,10 9,03 8,97 8,90 2,33 2,53 2,74 2,94 3,91 3,61 3,32 3,03 7,13 6,84 6,56 6,27 5,50 5,73 5,97 6,20-2 9,80 9,74 9,67 9,61 2,34 2,55 2,76 2,97 4,19 3,87 3,55 3,24 7,85 7,56 7,28 6,99 5,50 5,77 6,03 6,300 10,30 10,24 10,18 10,12 2,35 2,56 2,78 2,99 4,38 4,05 3,72 3,38 8,37 8,08 7,79 7,51 5,50 5,77 6,03 6,302 11,00 10,93 10,86 10,79 2,36 2,58 2,79 3,01 4,66 4,30 3,94 3,58 9,09 8,79 8,49 8,19 5,50 5,77 6,03 6,305 11,80 11,77 11,73 11,70 2,36 2,58 2,81 3,03 5,00 4,62 4,24 3,86 9,94 9,67 9,40 9,13 5,50 5,77 6,03 6,307 12,50 12,42 12,34 12,27 2,37 2,59 2,82 3,04 5,27 4,86 4,45 4,03 10,66 10,35 10,03 9,71 5,40 5,70 6,00 6,30
10 13,10 13,03 12,95 12,88 2,38 2,60 2,83 3,05 5,50 5,08 4,65 4,22 11,28 10,97 10,66 10,34 5,30 5,63 5,97 6,3012 13,80 13,72 13,63 13,55 2,38 2,60 2,83 3,05 5,80 5,35 4,89 4,44 12,02 11,70 11,38 11,05 5,30 5,63 5,97 6,3015 14,40 14,29 14,18 14,08 2,39 2,61 2,84 3,06 6,03 5,55 5,08 4,60 12,64 12,29 11,94 11,60 5,30 5,60 5,90 6,2018 14,70 14,56 14,43 14,29 2,39 2,61 2,84 3,06 6,15 5,66 5,16 4,67 12,96 12,58 12,20 11,82 5,40 5,67 5,93 6,20
Eco-energy technicRoth Solargeo
standard conditions
07.05.2009 Christian Dersch 22
performance dataHeat pump: SW 10
empf. Volumenstrom Heizung: 2 m³/hempf. Volumenstrom Quelle: 2,8 m³/h
Kältemittel: R 407CKältemittelinhalt: 1,8 kg
supply temp. 35 40 45 50 35 40 45 50 35 40 45 50 35 40 45 50 35 40 45 50in °C
source temp. Heat output in kW power consumption in kW performance number refrigeration capacity in kW charging rate in Ain °C
-5 9,10 9,03 8,97 8,90 2,33 2,53 2,74 2,94 3,91 3,61 3,32 3,03 7,13 6,84 6,56 6,27 5,50 5,73 5,97 6,20-2 9,80 9,74 9,67 9,61 2,34 2,55 2,76 2,97 4,19 3,87 3,55 3,24 7,85 7,56 7,28 6,99 5,50 5,77 6,03 6,300 10,30 10,24 10,18 10,12 2,35 2,56 2,78 2,99 4,38 4,05 3,72 3,38 8,37 8,08 7,79 7,51 5,50 5,77 6,03 6,302 11,00 10,93 10,86 10,79 2,36 2,58 2,79 3,01 4,66 4,30 3,94 3,58 9,09 8,79 8,49 8,19 5,50 5,77 6,03 6,305 11,80 11,77 11,73 11,70 2,36 2,58 2,81 3,03 5,00 4,62 4,24 3,86 9,94 9,67 9,40 9,13 5,50 5,77 6,03 6,307 12,50 12,42 12,34 12,27 2,37 2,59 2,82 3,04 5,27 4,86 4,45 4,03 10,66 10,35 10,03 9,71 5,40 5,70 6,00 6,30
10 13,10 13,03 12,95 12,88 2,38 2,60 2,83 3,05 5,50 5,08 4,65 4,22 11,28 10,97 10,66 10,34 5,30 5,63 5,97 6,3012 13,80 13,72 13,63 13,55 2,38 2,60 2,83 3,05 5,80 5,35 4,89 4,44 12,02 11,70 11,38 11,05 5,30 5,63 5,97 6,3015 14,40 14,29 14,18 14,08 2,39 2,61 2,84 3,06 6,03 5,55 5,08 4,60 12,64 12,29 11,94 11,60 5,30 5,60 5,90 6,2018 14,70 14,56 14,43 14,29 2,39 2,61 2,84 3,06 6,15 5,66 5,16 4,67 12,96 12,58 12,20 11,82 5,40 5,67 5,93 6,20
Eco-energy technicRoth Solargeo
Roth Solargeo
07.05.2009 Christian Dersch 23
Example ground-flat collector / Solargeo register station:
space area ca. 345 m² ca. 60 m² (parallel arrangement)pipe demand ca. 430 m ca. 720 m (6 register)pipe installing distance 0,8 m 0,8 m (between register)installation depth ca. 1,2 m ca. 2,0 mground excavation ca. 415 m³ (laminar abrasion )ca. 65 m³ (trench form 0,8 m width)
Eco-energy technicRoth Solargeo
Earthworks
07.05.2009 Christian Dersch 24
Solargeo -
register trench800
800
1100
Eco-energy technicRoth Solargeo