© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314
Page ___ of ___ Form Version: January 2013 CSI Form 1.5C
SUBSTITUTION REQUEST
(During the Bidding/Negotiating Stage)
Project:
To:
Re:
Substitution Request Number:
From:
Date:
A/E Project Number:
Contract For:
Specification Title:
Section: Page:
Description:
Article/Paragraph:
Proposed Substitution: Address: ______________________________________ Phone: Manufacturer: Insulfoam
Trade Name: Insulfoam/InsulGrade Model No.:
Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.
Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.
The Undersigned certifies: • Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.• Same warranty will be furnished for proposed substitution as for specified product.• Same maintenance service and source of replacement parts, as applicable, is available.• Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.• Proposed substitution does not affect dimensions and functional clearances.• Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the
substitution.
Submitted by:
Signed by:
Firm:
Address:
Telephone:
A/E’s REVIEW AND ACTION
Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials.
Signed by: Date:
Supporting Data Attached: Drawings Product Data Samples Tests Reports
Re: Inclusion of InsulGrade R-Tech insulation in your specification
Insulfoam, a Carlisle Company, submits for your approval a code-approved equivalent
below-grade & under-slab insulation alternative on the referenced project.
InsulGrade R-Tech (Insulfoam R-Tech) insulation, which comes with factory-laminated
moisture-resisting facers, meets the physical property requirements listed in your specification.
InsulGrade R-Tech has numerous code approvals and is recognized by IBC for use in below-
grade and under-slab applications. It contributes towards LEED credits and can be recycled.
More information is available at www.Insulfoam.com or can be provided upon request.
All Insulfoam R-Tech insulations come with a fully-warranted stable R-value (our
products are not impacted by LTTR R-value reductions) and offer superior compressive strength.
For your review, we are enclosing:
1. InsulGrade R-Tech technical data sheet
2. Our 100% R-value Warranty for R-Tech
With over 50 years of design experience, nationwide manufacturing in the US, and
dedicated R&D centers that lead insulation research, Insulfoam has been supporting architectural
and building owner communities by offering some of the most effective insulation solutions.
We look forward to extending that value and support on the referenced project.
Please contact the undersigned, or visit www.Insulfoam.com for more information.
Sincerely,
Insulfoam
Engineered EPSVersatile - Durable - Sustainable
Nationwide Manufacturing n Toll Free: (800) 248-5995 n www.Insulfoam.com
DescriptionR-Tech is an engineered rigid insulation consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS) with advanced polymeric laminate facers. R-Tech is available with factory adhered metallic-refl ective facers, white facers or a combination of the two. The core of R-Tech is the same high-quality EPS as our InsulGrade brand insulations and meets or exceeds the requirements of ASTM C578, Type I, Standard Specifi cation for Rigid, Cellular Polystyrene Thermal Insulation. In addition, R-Tech has excellent dimensional stability, compressive strength and water resistance properties. R-Tech is an ENERGY STAR® qualifi ed insulation and can contribute toward LEED® credits.
UsesR-Tech has been used successfully for numerous commercial, industrial and residential applications, insulating the foundation wall or slab and protecting the waterproofi ng or damp proofi ng, especially during backfi lling. The following are examples of the many R-Tech applications:
¡ Architectural Shapes ¡ Below-grade Insulation ¡ Docks & Piers ¡ Void Fill ¡ Ramps & Bridge Approaches ¡ Freezers & Cold Storage
Advantages ¡ Environmentally Friendly. R-Tech does not contain any dyes,
may contain recycled material and the foam core is 100% recyclable.
¡ User Friendly. R-Tech can be ordered with the InsulSnap™
feature which scores the product longitudinally at any pre-ordered interval (commonly 16" or 24" o.c.). The InsulSnap feature minimizes labor by enabling the installer to cleanly break the product at the desired width while also minimizing product breakage and waste.
¡ Insect and Mold Resistance. R-Tech is manufactured with an inert additive that deters termites and carpenter ants. R-Tech does not sustain mold and mildew growth.
¡ Water Resistance. R-Tech facers provide a surface that is virtually impervious to moisture.
¡ Drainage Board ¡ Pre-cast/Pre-stressed
Concrete Panels ¡ Road Base ¡ Foundations ¡ Retaining Walls
¡ Jobsite Durability. With a polymeric facer on either side of it, R-Tech is extremely fl exible and durable.
¡ Stable R-value. The product’s thermal properties will remain stable over its entire service life. There is no thermal drift, so the product is eligible for an Insulfoam 20-Year Thermal Performance Warranty.
¡ Cost Effective. R-Tech is typically less expensive than other comparable insulation products.
¡ Proven Performance. EPS has been manufactured using the same chemistry since the mid-1950s, providing proven performance.
¡ Enhanced R-values. In certain applications, increased R-values can be obtained by placing the metallic refl ective side of the R-Tech towards a dead air space. R-value gain is dependent on the amount of dead air space between the R-Tech and outer surface. R-value gains are based on the ASHRAE Handbook of Fundamentals. See the attached Effective R-value chart.
SizesR-Tech is available in 4' x 8' sheets with thicknesses from 3/8"to 5" in 1/8" increments. R-Tech can also be ordered with the InsulSnap feature which allows the end user to cleanly break the 4' x 8' sheets into any desired width. All of the R-Tech insulation products are available with metallic refl ective and InsulFoam white facers. In addition, custom sizes and densities are available upon request with little or no impact on lead time.
PREMIUM BELOW-GRADE INSULATION
The Foundation of Moisture Resistance
Engineered EPSVersatile - Durable - Sustainable
Installation RecommendationsPlease refer to the appropriate R-Tech application sheets for recommended installation procedures.
PREMIUM BELOW-GRADE INSULATION
Nationwide Manufacturing n Toll Free: (800) 248-5995 n www.Insulfoam.com13010-10/14
Typical Physical Properties*
Property Type I Test Method
Nominal Density (pcf) 1.0 ASTM C303
C-Value (Conductance)BTU/(hr•ft2•°F)
@ 25° F(per inch) @ 40° F @ 75° F
.23
.24
.26
ASTM C518or
ASTM C177
R-value (Thermal Resistance)
(hr•ft2•°F)/BTU @ 25° F(per inch) @ 40° F @ 75° F
4.354.173.85
ASTM C518or
ASTM C177
Compressive Strength(psi, 10% deformation)
13 ASTM D1621
Flexural Strength (psi) 33 ASTM C203
Dimensional Stability(maximum %)
< 2% ASTM D2126
Water Vapor Transmission(perms)
< 1.0 ASTM E96
Absorption (% vol.) < 1.0 ASTM C272
Capillarity none –
Flame Spread < 20 ASTM E84
Smoke Developed 150 - 300 ASTM E84
*Properties are based on data provided by resin manufacturers, independent test agencies and Insulfoam.
R-Tech Thickness
Design Temp.Effective R-value
(R-Tech MR + Air Space) b
0.5"25° F40° F75° F
5.004.904.80
0.75"25° F40° F75° F
6.105.905.70
1.00"25° F40° F75° F
7.207.006.70
1.25"25° F40° F75° F
8.308.007.60
1.50"25° F40° F75° F
9.409.108.60
1.75"25° F40° F75° F
10.5010.109.60
2.00"25° F40° F75° F
11.6011.1010.50
2.25"25° F40° F75° F
12.7012.2011.50
2.50"25° F40° F75° F
13.8013.2012.40
a Effective R-values determined using InsulGrade I. Higher density InsulGrade products will provide higher R-values. The type of construction application and the depth of the air space will also impact the actual Effective R-value.
b Requires 0.75”- 3.50” dead air space and the R-Tech MR facer towards the dead air space.
Effective R-valuesa (metallic-refl ective facer and dead air space)
The Foundation of Moisture Resistance
INSULFOAM- a division of Carlisle Construction Materials 19727 57th Ave. East, Puyallup WA. (253) 271-3056 Fax (253) 271-3265 www.insulfoam.com
Owner’s Name: Building Name:
Owner’s Address: Building Address: Warranty Number: Warranty Effective Date:
Insulfoam. Insulfoam, a division of Carlisle Construction Materials Incorporated (“Insulfoam”) hereby warrants for a period of 20 years, commencing with the warranty effective date, that the R‐Tech thermal resistance (R‐value) will meet or exceed the values stated below. If the product is determined by sampling and tests (conducted as provided below) to not meet the warranty values stated below, Insulfoam will, in its sole discretion, either deliver to the Owner a quantity of equivalent Insulfoam product to replace the non‐performing Insulation or refund to the Owner the original purchase price of the non‐performing Insulation. Insulfoam’s total liability over the life of this warranty shall not exceed the original purchase price of the insulation.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND SHALL NOT BE EXTENDED OR ALTERED EXCEPT BY WRITTEN INSTRUMENT SIGNED BY INSULFOAM. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION SET FORTH IN THIS WARRANTY. INSULFOAM SPECIFICALLY DISCLAIMS LIABILITY FOR ANY DIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, INCLUDING, BUT NOT LIMITED TO, INCREMENTAL HEATING, COOLING OR SIMILAR COSTS, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW WHATSOEVER.
Conditions. Insulfoam’s obligations under this Warranty will only take effect if installed in strict accordance with all applicable Insulfoam specifications, recommendations and guidelines which were in effect at the time of installation. Originals or copies of invoices and bills showing the cost of the EPS Insulation shall be submitted along with any claims under this Warranty Agreement. Insulfoam’s failure at any time to enforce any terms or conditions stated herein shall not be construed to be a waiver of its right to enforce that term or condition. Exclusions. This Warranty shall be void if, in Insulfoam’s judgment, the R‐Tech’s performance has been impaired by either damage or alterations (lacking prior Insulfoam written approval) to the product. Insulfoam does not warrant the compatibility of the R‐Tech with any other products including, but not limited to, any roofing or waterproofing membranes or coatings. Insulation Testing. All sampling shall be conducted in accordance with sampling procedures prescribed by Insulfoam, and samples of the R‐Tech shall only be taken in the presence of an authorized Insulfoam representative. Testing of the R‐Tech samples shall be in accordance with ASTM Test Method C518 or the then closest Insulfoam‐approved effective equivalent test method. R‐Tech samples shall be conditioned to equilibrium prior to testing. All sampling and testing costs (including but not limited to costs of R‐Tech uncovering, removal and replacement) shall be at the Owner’s sole expense.
Thermal Values. The R‐Tech product will have the following thermal resistance (R‐value) on a per inch
basis:
R‐Tech R‐value of 4.17 when tested at 40F R‐value of 3.85 when tested at 75F
R‐Tech®20‐Year Limited Thermal Warranty