Cse & WTe 1000FlaT bed uniT1 or 2 roW oF Fans
air cooLed condensed Unit | drY cooLer Unit
AIR CONDENSER AND lIquID COOlERSwITH AxIAl fANS• Configuration: 1 or 2 exchangers• 1 or 2 indipendent circuits• 1 or 2 fans row• Wide range of capacity• 72 models available as condenser• 72 models available as dry cooler• Fan diameter: 1000 mm• Number of fans: from 1 to 8• Vertical or horizontal installation
COSTRuCTION CHARACTERISTICSThey are realized with technologies and material which guarantee strength against atmospheric agents.High efficiency finned block heat exchangers realized with copper tubes and alluminium fins. New generation axial fans with 1000 mm diameter both available version AC and EC chosen for minimizing the energy consumption. Standard unit are supplied with cabled fans and electrical box with clamps.
AVAIlAblE fANSBTD: 6-poles with delta connectionBTY: 6-poles with star connectionSTD: 8-poles with delta connectionSTY: 8-poles with star connectionCTB: fan motor EC high powerCTS: fan motor EC low noise level
ACCESSORIESCSE and WTE unit could be equipped with main switch, switchboard, cut phase fan speed regulator (with 1 set point or 2 set point) or inverter with shielded cables, EC controller and temperature sensor, pressure sensor or 0-10V signal.All fan motors could be equipped with switch for each motor. Anti-vibration device are also available for reducing machine’s vibrations and only for dry coolers flanges in oreder to simplify hydraulic connection.
Models
Model
Main switch
Switch for each motor
Switchboard
Phase cut regulatori
Controller ec Inverter
Probe
Anti-vibration
device
CSE-WTE BTD p p p p p p p
CSE-WTE BTY p p p p p p p
CSE-WTE STD p p p p p p p
CSE-WTE STY p p p p p p p
CSE-WTE CTB p p p p p p
CSE-WTE CTS p p p p p p
Cse condenser and WTe dry cooler’s serie meet equipment’s power requirements.They are available from 1 up to 8 fans both version aC and eC
CApACITYIn air condenser unit power range with refrigerant R134a is from 12.8 up to 252.8 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)
In air condenseer unit power range with refrigerant R410A is from 14.7 up to 267.7 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)
In dry cooler unit power range with ethylene glycol 30% is from 11.4 up to 214.7 tons (ambient air temperature +77°F, inlet liquid temperature +104°F outlet liquid temperature +95°F according to EN 1048)
TeChniCal draWinG
Quota a
- CSE/WTE° 101(3/4) (single row of fans)
- CSE/WTE° 102(3/4) (single row of fans)
- CSE/WTE° 103(3/4) (single row of fans)
- CSE/WTE° 104(3/4) (single row of fans)
- CSE/WTE° 106(3/4) (double row of fans)
- CSE/WTE° 108(3/4) (double row of fans)
20 120
220
320
420
520
620
720
820
920
CTS
CTB
STY
STD
BTY
BTD
kW (T.air 25°C - T.cond 40°C)
CSE 1000 R134a
50 150
250
350
450
550
650
750
850
950
CTS
CTB
STY
STD
BTY
BTD
kW (T.air 25°C - T.cond 40°C)
CSE 1000 R410A
20 70 120
170
220
270
320
370
420
470
520
570
620
670
720
770
CTS
CTB
STY
STD
BTY
BTD
kW (T.air 25°C - T.liq 35/40°C)
WTE 1000
90.5 in
181.1 in
271.6 in
362.2 in
271.6 in
362.2 in
Quota A 95.7 in
69.3 in
49.5 in
69.3 in
44.4 in
49.2 in
61.4 in
95.5 in
AERMECAddress: 1608 Bonhill Road. Mississauga, Ontario, CA L5T 1C7Website: www.aermec.usEmail: [email protected]: 1-800-567-2221US: 1-888-567-2227