00 - Ground Floor
101270
01 - First Floor
105640
Vertical Metal Cladding PanelsGlazing with aluminium frame Grey Engineering BricksGrey Engineering Bricks
Roof Level
11450
SIGNAGE ZONE
Close-board Black Stained Vertical Timber Cladding to 2.4m afflOpen-board Black Stained Vertical Timber Cladding above 2.4m affl
Door Size TBC
Transom "2260mm
00 - Ground Floor
101270
01 - First Floor
105640
Close-board Black Stained Vertical Timber Cladding to 2.4m affl Grey Engineering Bricks
Close-board Black Stained Vertical Timber Cladding to 2.4m afflOpen-board Black Stained Vertical Timber Cladding above 2.4m affl
Grey Engineering Bricks Grey Engineering Bricks
Roof Level
11450
Vertical Metal Cladding Panels Vertical Metal Cladding PanelsVertical Metal Cladding Panels
Close-board Black Stained Vertical Timber Cladding to 2.4m afflOpen-board Black Stained Vertical Timber Cladding above 2.4m affl
00 - Ground Floor
101270
01 - First Floor
105640
Glazing with aluminium frame Grey Engineering Bricks Glazing with aluminium frame Glazing with aluminium frameGrey Engineering BricksGrey Engineering Bricks Grey Engineering BricksVertical Metal Cladding Panels
2480
Roof Level
11450
Grey Engineering Bricks
SIGNAGE ZONE
Door Size TBC
Transom "2260mm
Door Size TBC
Transom "2260mm
TOS FF Curtain Wall Restraint
108440
00 - Ground Floor
101270
01 - First Floor
105640
Metal Cladding StripGrey Engineering Bricks Grey Engineering Bricks
Roof Level
11450
Close-board Black Stained Vertical Timber Cladding to 2.4m afflOpen-board Black Stained Vertical Timber Cladding above 2.4m affl
1:1250
1:100
1:200
1000 3000 5000
1:500 5 15 25
10 30 50 70
M
mm
mm
M
5000 8000
The Contractor is to check all dimensions and conditions on site before commencing. Do not scale from this drawing.This drawing remains the copyright of POZZONI Architecture ltd.
Scale Bars TO BE USED ONLY AS GUIDANCE
Notes
+44 161 928 7848
Woodville House2 Woodville Road
Altrincham
WA14 2FH
Contract As Built
Planning
Design
Tender Construction
Client
Job
Drawing
POZ Ref.
Rev
London House115 Golden LaneLondon
EC1Y 0TJ
+44 20 7078 0079
Scale
3D
CoO
rd
Appro
ved
Date
Pro
ject S
tatu
s
www.pozzoni.co.uk
2D
Co
Ord
@ A1
BS.Ref
C:\RevitLocalFiles\P4897_PAL_Z2_XX_M3_A_0006_TWC-DENTON_Building Central_dspoors.rvt08/05/2019 10:47:41
1 : 200
Proposed GA Elevations
27/06/17
Willmott Dixon Construction Ltd
Wellness Centre Denton
P4897_03000 C05
- RR MB
TWCD-PAL-Z1-XX-DR-A-03000
1 : 200
West - Proposed
1 : 200
South - Proposed
1 : 200
North - Proposed
1 : 200
East - Proposed
Rev Description By Date
P1 Added netwoek space landannotation.
IZ 29/06/17
P2 Redline boundary shown. DAS 04/07/17
P3 Updated layout to suit sketchproposal.
IZ 26/07/17
P4 Updated to suit layout changes. RR 27/07/17
P5 Updated Elevations; Access tochanging vilage and servery toBowling ally.
RR 22/09/17
P6 Revised Areas RR 15/11/17
P7 Elevations updated to suit currentlayout
JC 24/04/18
P8 Area of curtain walling removed andwall finishes updated
JC 25/04/18
P9 M&E Updated with Plant Roomgrille amended & signage zonesindicated
RJF 03/05/18
P10 Updated to reflect current WIPmodel
RJF 12/06/18
P11 Plant enclosure added RJF 12/07/18
P12 Curtain wall added to Bowling RJF 13/07/18
P13 Numbering updated to suit BIMstandards
RJF 01/08/18
P14 Numbering Updated to Suit BIMStandards & Updated followingRemoval of External Door
JB 04/10/18
C01 Minor updates to door positions withadditional mullions added to curtainwalling
RJF 27/11/18
C02 Updated in accordance with revisedplant screen
JB 05/12/18
C03 West and east elevations to plantscreen adjusted in height along withadditional triangulation on plantscreen south elevation.
DAS 01/05/19
C04 Updated plant screen profile. IZ 07/05/19
C05 End elevations to plant screenreduced in size.
DAS 08/05/19