1
Welcome to our latest edition of Automotive Essential instruments
Kane International is the UK’s foremost manufacturer & supplier of hand-held exhaust emissions testers & portable test equipment.
As a supplier to some of the leading names in the Automotive Aftermarket Kane International sets the
standard for quality, reliability & portability.
GO ANYWHERE, USE ANYWHERE
Contents
These symbols help you select your analyser
Option
Car Bike Truck FLT
Cab Heater Information
Wireless option Sensor option UK Made
MID
Analysers 2-11 AUTO7 2 AUTOplus4-2 3-4 AUTOplus5-2 3-4 AUTO4-1/MID 5 AUTO5-1/MID 5 AUTO4-1 6 AUTO5-1 6 KANE501C 7 KANE504 8 KANE504-INT-SPH 8 KANE AUTO600 9-10 KANE100-1 11 KANE100-1 KIT 11Indoor Air Quality 11-12Leak Detection 13Pressure Meters 14Thermometers & Temp Probes 15-16Probes 17Software 17Accessories/Consumables 18Contact Details 19
2
Contents 4 Line Automotive Exhaust Gas Analyser
Measures• CO (0-10,000ppm) • CO2 (0-20%) Calculates• COK Corrected CO (0-15,000ppm)• NOx (0-1,500ppm)
Fuel Types• Petrol/Gasoline• LPG
Features• 4 Line display• Store upto 99 tests• Compact design• Protective rubber cover with a magnet for “hands–free”
operation• CO2 direct measurement with a "long life" infra-red
sensor • CO direct measurement• Rotary switch for ease of use• Integrated water trap with replaceable particle filter• Low cost yearly fixed price servicing• Print capability - With optional printer KANE IRP-2
• CNG• Diesel
Contents• Analyser inc. x4 AA batteries, Protective Rubber Boot, High Temp Probe, Spare Filters, Manual, Carry Case
Kit options• Kits can be customised to suit your requirements
AUTO2-7• Gas Analyser - CO, COK, CO2
AUTO3-7• Gas Analyser - CO, COK, CO2, NO, NOx
AUTO2-7 KIT• Gas Analyser - CO, COK, CO2, KANE IRP-2 printer
AUTO3-7 KIT• Gas Analyser - CO, COK, CO2, NO, NOx, KANE IRP-2 printer
AUTO7
Compact & easy to use designIdeal for exhaust emission monitoring of CO, CO2, & NO (optional)
• NO (0-1,500ppm) optional
3
Exhaust Gas Analyser
Measures• CO (0-10%) • CO2 (0-16%) • HC (0-5000ppm)• O2 (0-21%)
Calculates• Lambda / AFR
Fuel Types• Petrol/Gasoline• LPG
Features• Fast warm up• AC & 12v Chargers• Up to 4 hours internal battery life• Multilingual software• Ideal for pre-compliance testing, vehicle diagnostics
and servicing to manufacturers specification.• Easily maintained & low cost of ownership• Monochrome QVGA Display - Easy to read & informative graphic display• Wireless - Links easily to PC or appropriate wireless devices (additional software required)• Compact design - Can incorporate 4 or 5 gas option• Pump speed control - Improves battery life• Improved print capability - Select faster printing when used with optional KANE IRP-2 - Wireless - USB with optional cable & software - Standard print with optional KMIRP
• CNG• Diesel
Contents• Analyser, Protective Rubber Boot, High Temp Probe,
AC & 12V Chargers, Spare Filters, Manual, Carry Case & optional IR Printer
Kit options• Kits can be customised to suit your requirements
AUTOplus4-2• 4 Gas Analyser - CO, CO2, HC, O2 & Lambda / AFR
AUTOplus5-2• 5 Gas Analyser - CO, CO2, HC, O2, Lambda / AFR & NOx
• Lambda/AFR (0.8-1.2)• NOx (0-5000ppm) optional
AUTOplus4-2AUTOplus5-2
All of the features you would expect from a Kane Exhaust Gas Analyser
Option
4
Wireless connectivity• Transfer analyser readings to your PC or AndroidTM Phone using “KANE LIVE” software or “Printer App for AndroidTM ” downloaded FREE from www.kane.co.uk
KANE LIVE Software• Easily connects the KANE AUTOplus to
a PC via wireless• All readings in “real time” displayed
digitally & in graph form• Helps identify emission related faults• Features include: - Update user details - Toggle pump on/off - Save & download data - Customise graphing
5
MID Exhaust Gas Analysers
Measures• CO (0-10%) • CO2 (0-16%) • HC (0-5000ppm)• O2 (0-21%)
Calculates• Lambda/AFR (0.8-1.2)
Fuel Types• Petrol/Gasoline• LPG
Features• Fast warm up• AC & 12v Chargers• Up to 4 hours internal battery life• Multilingual software• Ideal for pre-compliance testing, vehicle diagnostics &
servicing to manufacturers specification.• Easily maintained & low cost of ownership• Compact design - Can incorporate 4 or 5 gas option• Secure print capability - When used with optional KANE IRP-2/MID
• CNG• Diesel
• Introducing the world’s first fully portable MID (2004/22/EC) approved gas analyser that sets the standard of convenience & ease of use.
• A multi-functional four or five gas analyser designed for regulated emission testing including Dutch APK & Germany’s AUK for motorcycles.
AUTO4-1/MIDAUTO5-1/MID
MID Approved 4 & 5 Gas Analyser
MID Certification
Contents• Analyser, Protective Rubber Boot, High Temp Probe,
AC & 12V Chargers, Spare Filters, Manual, Carry Case & optional IR Printer
Kit options• Kits can be customised to suit your requirements
AUTO4-1/MID• 4 Gas Analyser - CO, CO2, HC, O2 & Lambda / AFR
AUTO-1/MID• 5 Gas Analyser - CO, CO2, HC, O2, Lambda / AFR & NOx
• Lambda/AFR (0.8-1.2)• NOx (0-5000ppm) (AUTO5-1/MID only)
6
OIML CLASS 1 & Standard Exhaust Gas Analysers
Measures• CO (0-10%) • CO2 (0-16%) • HC (0-5000ppm)• O2 (0-21%)
Calculates• Lambda/AFR (0.8-1.2)
Fuel Types• Petrol/Gasoline• LPG
Features• Fast warm up• AC & 12v Chargers• Up to 4 hours internal battery life• Multilingual software• Ideal for pre-compliance testing, vehicle diagnostics &
servicing to manufacturers specification.• Easily maintained & low cost of ownership• Compact design - Can incorporate 4 or 5 gas option• Print capability - With optional printer KANE IRP-2
• CNG• Diesel
• Lambda/AFR (0.8-1.2)• NOx (0-5000ppm) (AUTO5-1 only)
• Certified to be compliant with OIML R99 Class 1 (ISO 3930), under Test Report No N0356 of January
2001 issued by the duly authorised and approved OIML test body SIRA Test & Certification Ltd of the UK.
• Compliance to OIML standards is often a requirement for regulated emission testing programmes around the world. Each analyser is supplied with a test report.
AUTO4-1AUTO5-1
OIML Class 1, 4 & 5 Gas Analyser for use when traceable certification is required
Contents• Analyser, Protective Rubber Boot, High Temp Probe,
AC & 12V Chargers, Spare Filters, Manual, Carry Case & optional IR Printer
Kit options• Kits can be customised to suit your requirements
AUTO4-1• 4 Gas Analyser - CO, CO2, HC, O2 & Lambda / AFR
AUTO5-1• 5 Gas Analyser - CO, CO2, HC, O2, Lambda / AFR & NOx
7
Combustion Performance Tester
KANE501C
Set optimal combustion levels for CO2 on cab heaters to ensure safe & efficient performance in accordance with manufacturer’s recommended procedures
Applications• Webasto & Spheros heaters supplied to leading
manufacturers of buses, trucks, cars, vans, leisure vehicles etc.
• Domestic or commercial boilers, mobile cleaning/ weed control equipment with water heaters
Measures• CO2 (0-20%) • Flue temperature (0-600º)*Calculates• Efficiency (0-110%)*• O2 (0-25%) Fuels Types• Natural Gas• Propane• Light OilFeatures• CO2 direct measurement with a "long life" infra-red
sensor • Rotary switch for ease of use• Integrated water trap with replaceable particle filter• Special clip-on probe designed for heater applications• Low cost yearly fixed price servicing
* Requires probe fitted with a thermocouple
Independently tested by TÜV SUD to: EN50379 Use for: BS7967
Contents• Analyser, probe, 4 x AA batteries, manual, calibration
report
Kit options• Kits can be customised to suit your requirements
KANE501C-INT-WB• Combustion performance test kit
KANE501C-DE-WEB• As KANE501C-INT-WB with German software
• Heavy Oil• Wood• Coal
• Excess air (0-250%)*
8
Combustion Analyser - Direct CO2 & CO Measurement
KANE504
Set optimal combustion levels for CO & CO2 on cab heaters to ensure safe & efficient performance in accordance with manufacturer’s recommended procedures
Applications• Webasto & Spheros heaters supplied to leading
manufacturers of buses, trucks, cars, vans, leisure vehicles etc.
• Domestic or commercial boilers, mobile cleaning/ weed control equipment with water heaters
Measures• CO2 (0-20%) • Flue temperature (0-600º)*Calculates• Efficiency (0-110%)*• O2 (0-25%) Fuels Types• Natural Gas• Propane• Light OilFeatures• CO2 direct measurement with a "long life" infra-red
sensor • CO direct measurement• Rotary switch for ease of use• Integrated water trap with replaceable particle filter• Special clip-on probe designed for heater applications• Low cost yearly fixed price servicing
* Requires probe fitted with a thermocouple
Direct measurement of CO2 & CO
Independently tested by TÜV SUD to: EN50379 Use for: BS7967
Contents• Analyser, probe, 4 x AA batteries, manual, calibration
report
Kit options• Kits can be customised to suit your requirements
KANE504-INT-SPH• Combustion Analyser - Direct CO2 & CO Measurement
• Heavy Oil• Wood• Coal
• CO (0-2000ppm)
• Excess air (0-250%)*
9
Portable Diesel Smokemeter
Applications • The AUTO600 is a portable & re chargeable ‘partial
flow’ diesel engine Smokemeter designed for “Continuous” & “Peak” testing of exhaust gases in diesel vehicles.
• It is designed to meet recognised standards for accuracy & repeatability for Category A (Cars & Light Commercial) & Category B (Commercial) vehicles
Measures• Hartridge units (%H) & k (/m)Fuel Types• DieselFeatures• Fully portable - AC & internal
rechargeable battery with up to 3 hours run time
• Ergonomic easy to use handset
• Compact rugged housing, strong but light, easy to position for all types of vehicles
• Wireless or cable operation• Peak measurement %Hu & /m• Self calibration after each test
maintains accuracy• Tests can be printed using the
infra-red printer (included)Operation• The AUTO600 takes a sample
of exhaust gas through a flexible probe inserted into the vehicle’s exhaust.
• The gases are passed through a tube that is illuminated by a near monochromatic visible light source.
• The obscuration of this light gives an accurate measurement of the density of the smoke emitted by the vehicle.
KANE AUTO600
Combining innovation & ease of use the AUTO600 is designed to meet official test standards
Contents• Hand Set, Protective Rubber Boot, Smoke Unit, High Temp Probe, AC & 12V Chargers, Spare Filters,
Manual, Carry Case & IR Printer
Option
10
The AUTO600 is ideal for:• Vehicle Servicing & Maintenance• Pre-compliance Testing• Environmental Monitoring• Fleet Operators• PSV Workshops• Materials Handling Operators• Marine• Car & Commercial Vehicle Workshops• Agricultural Workshops• Local Authorities
What factors effect the composition of diesel smoke emission?The quantity and composition of diesel smoke may vary depending on:• The quality of diesel fuel used• The type of engine, e.g. standard, turbo or injector• The state of engine tuning• The fuel pump setting• The workload demand on the engine• The engine temperature• Whether the engine has been regularly maintained
11
ApplicationMeasures & logs ambient carbon monoxide (CO) &
carbon dioxide (CO2) levelsChecks that flueless gas appliances including space
heaters, water heaters & kitchen equipment are operating safely
Test CO & CO2 for indoor air quality (IAQ) checks
MeasuresAmbient CO 0-1,000ppmAmbient CO2 0-9,999ppm
Features• Rotary switch for ease of useData-logs up to 255 records with variable sampling
time from 1-10 minutes Records time & date Prints to optional printer using infra-red emitter (Printer
sold separately) User adjustable alarms for CO & CO2 Long life NiMh batteries charged in situ with charger Internal pump for fast measurements in room air or
ducts Long sampling hose for ‘silent’ sampling of high profile
/ public areas Headers can be customised by the user
Indoor Air Quality Analyser
Use for: BS8494
KANE100-1
IAQ analyser with 5 year life sensors
Contents• Analyser, probe, charger, manual,
calibration report, CO2 true zero capsule
KANE100-1• Indoor Air Quality Analyser
KANE100-1 KIT• As KANE100-1 plus KANE IRP-2 printer &
carry case
KANE-ALERT-CO2
DAFM3
KANE1010
KANE77
Assess CO2 levels & ventilation efficiency in locations where indoor air quality is important
Measures• Long life NDIR sensor measures carbon dioxide (CO2)
up to 10,000 parts per million (ppm)• Temperature 0 - 50°C• Max/Min mode• Alarm mode• Logs up to 48 readings at 30 minute interval
Calculates• Calculates & displays ventilation rates
Features• Adjustable alarm• Battery life typically 80 hours using 4 x AA batteries• Supplied with mains adapter• Fitted with tilt stand for ease of use
Digital “Rotating Vane” Air Flow Meter Ideal for commercial catering applications
Measures• Air Velocity• Temperature• Relative Humidity
Calculate• Dew Point• Air Volume
Wireless H&V Remote Monitor Monitor & record temperature, air flow & humidity using KANE LIVE
Applications• Monitor air conditioning evaporator units performance• Monitor flow & return temperature of loft fitted central
heating boilers• Balance centralised heating or air conditioning units using multiple KANE1010 monitors
Personal CO Monitor for ambient carbon monoxide (CO) levels in commercial & residential spaces
Measures• Measures CO from 0 to 999 ppm - Long life CO sensor with 5 year lifeFeatures• One button ON with Auto Zero• Captures maximum value• Preset Alarms• Vibrating Alarm• Visual three colour LED• Audible tone - If readings 30 ppm or above• Data Hold• Back lit display• Battery Indication
Indoor Air Quality
High levels of CO2 cause drowsiness, headaches or even long term damage
Exposure to high levels of Carbon Monoxide (CO) can be fatal
Note: probes sold separately - see page 30
12
13
CD100A
GLD/450plus & GLD/451plus
Combustible Gas Leak Detector
Gas Leak DetectorsApplications• Pin-point small combustible gas leaksGases Detected
Acetone Gasoline/Petrol NapthaAlcohol Hydrogen Natural Gas Ammonia Industrial Solvents PropaneBenzene Jet Fuel ThinnersButane Lacquer TolueneEthylene Methane
Features• Flexible shaft 180mm long• Solid state semi-conductor sensor• Audible & visual indicators• Supplied with 2 x AA batteries• GLD/450plus nominal 50ppm methane detection limit• GLD/451plus nominal 250ppm methane detection limit
Leak Detection
Leak detectors do not measure gas levels
LS1/B
RD99
Leak Seeka Combustible Gas Leak Detector
Refrigerant Gas Leak Detector
Features• Detects CFC’s, HFC’s &
HCFC’s including R11, R22, R134A, etc
• High sensitivity setting locates R134A leaks to 3gm/year
• Flexible gooseneck probe
• Easy one handed operation
• Audible & visual indicators
• Rubber sleeve protects detector & probe
Features• Detects combustible gas
leaks to 50 ppm• Applications include Petrol/
Gasoline, LPG, CNG, Ethanol/ Ethyl Alcohol
• Flexible goose neck with illuminated tip to find awkward leaks
• Long life Sensor provides accurate detection
• Audio and visual tic rate, fully adjustable, increases as sensor tip approaches leak
• Rubber sleeve protects detector & probe
Features• Pinpoints combustible
gas leaks as low as 10ppm methane
• One handed operation using thumbwheel to set “tick” rate
• Flexible goose neck with illuminated tip to find awkward leaks
• Audible & visual alarm for operator safety
• Supplied with earpiece & soft carry case
14
Pressure MetersKANE3500 Range
High Accuracy Differential Pressure Meters
Description•Suitablefordifficultapplicationssuchasfluedraftmeasurement&measuringdifferentialpressureof
gas/airratiovalvesonhighefficiencyboilersFeatures• 5 versions available - see table forspecifications
• KANE3500-1 Resolution to 0.1 pascal / 0.001 mbar
• Temperature compensated for superior accuracy
• Switchable between high & low resolution
• Switchable between: mbar, Pa, hPa, kPa, mmHg, mmH2O, inH2O & PSI
• Data hold & max/min recording• Printouts include date/time &
user details• Automated Tightness Testing on
KANE3500-1 and KANE3500-2• Optional wireless
upgrade (see below)• Send printout data to
your mobile device using FREE Kane printer app
Option
KANE3250
PSI1000
Pressure Meter
Description• Industrial rechargeable pressure meter for use with
remote 1000 psi transducer. Features• User selectable units: mbar - range 0-68.9 kPa - range 0-6896 PSI - range 0-1000• One button zeroing
Pressure Transducer
• Remote pressure transducer (PSI1000 with 1/4 NPT thread)
• For use with KANE3250
KANE3200High Accuracy Differential Pressure Meter
Description• Easy to use, two button pressure meter with integral magnet for hands free operationFeatures• Switchable between: mbar, Pa, hPa, kPa, mmHg, mmH2O, inH2O & PSI• One button zeroing• Long battery life
KANE3500-1 Range ± 1 psi / 80 mbar KANE3500-2 Range ± 2 psi / 160 mbar KANE3500-5 Range ± 5 psi / 400 mbar KANE3500-15 Range ± 15 psi / 1040 mbarKANE3500-30 Range ± 30 psi / 2070 mbar
BTM/450Wireless Android module added to any KANE3500
BTM/450LEWireless iOS module added to any KANE3500
Note: Remote transducer - must be ordered separately (PSI1000)
15
Thermometers
INF151Infra-red Thermometer
Description• Easy, comfortable non-contact temperature testing
Measures• Extended Range -40 to 420°C (-40 to 788°F)
Features• One button switching• Laser pointer• 7-second auto hold• Three pre-set emissivity levels 0.85, 0.90 and 0.95• Backlight• Auto power off• Distance to spot ratio 8 to 1• MIN/MAX record• Switchable °C or °F readings
KANE601Rechargeable Type K Thermometer
Features• Rechargeable Type K thermometer • Compatible with any Type K
thermocouple probe• -50 to 999°C (-58 to 1830°F) at 0.1° resolution• 1,000 to 1,200°C (1832 to 2192°F) at 1° resolution• Transfer analyser readings to your
PC using KANE LIVE software downloaded FREE from
www.kane.co.uk• Supplied with charger & soft pouch
DT150 & DT200
H&V KIT
Digital Thermometers
Description• Durable, versatile & fast responding• Uses J, K or T thermocouple types • High accuracy• Backlight display is easy to readFeatures• Range -200 to +1,370°C (-328 to +2,498°F)• Timestamped multifunction record• Relative function displays temperature change• Data hold• Protective rubber boot
• DT150 Single input & dual display
• DT200 Dual input, triple display, differentialtemperature(ΔT)
Heating & Ventilating Kit (includes DT200)
Features• See DT200 for features & specification
• Supplied with: DT200 Differential
Thermometer 2 x KWA1 wrap around pipe
probes 1x KAL1 air liquid probe 1 x KSP1 surface probe 1 x KFT1 flexible probe Carry case
16
PDT550Pocket Thermometer
Description• Versatile, rugged pocket thermometer featuring an
extended temperature range, built-in magnetic mount & waterproof caseFeatures• Waterproof• Measures -50 to +300ºC (-58 to +572ºF)
Temperature Probes
KAL1 Air/liquid probe -50 to +500°C
KAL2 Heavy duty air/liquid probe -50 to +1100°C
KANE AFM3 Airflow,humidity&temperatureprobeforKANE1010
KCP1 Chisel Probe -50 to +500°C
KFT1 Thermocouplewireprobe,tefloncoated-50to+250°C
KFT2 Thermocouple wire probe, glass braid -50 to +500°C
KPCP Pipe Clamp Probe
KPCP2 Pipe Clamp Probe
KSP1 Light duty surface probe -50 to +500°C
KSP2 Heavy duty surface probe -50 to +500°C
KWA1 Wrap around pipe probe
TOO159 K type thermocouple adaptor
17
Probes SoftwareExhaust & Oil Temperature
EPAUTO1• Standard Probe• 4m plastic tubing • Insertion depth 350mm
EPAUTO2• Stainless Steel Probe• 4m plastic tubing • Insertion depth 350mm
EPAUTO3• Stainless Steel Probe inc inline70µfilter
• 4m plastic tubing • Insertion depth 350mm
EPAUTO4• Standard Probe inc inline
water trap• 4m plastic tubing • Insertion depth 350mmEPAUTO5• Hi Temp Probe inc inline 70 µfilter
• 6m neoprene tubing • Insertion depth 300mm
EPAUTO6• Motorcycle Probe inc
thermocouple• 1.5m tubing • Insertion depth 230mm
EPAUTO7• Stainless Steel Probe• 4m neoprene tubing • Insertion depth 200mm
EPAUTO8• Motorcycle Probe• 1.5m tubing • Insertion depth 230mm
EPAUTO9• Hi Temp Probe• 6m neoprene tubing • Insertion depth 300mm
SM11284• Oil Temp Probe
AUTOSWKIT• PC Software suitable for
AUTO4-1, AUTO5-1
KANE LIVE• PC Software suitable for
AUTOplus
4GAGAR• Diagnostic software for
exhaust gas analysis
KANE IRP-2• Kane Infra-Red Printer• Faster print option (Autoplus
only) & fast load paper roll• Supplied with rechargeable
batteries
KANE IRP-2/MID• Printer for use with Kane MID
Gas Analysers only
17516• RPM Clamp
Spare Parts
SM11105• RD99 tip assembly
17143• CD100A/LS1 sensor
Batteries Chargers & Power Leads
CU12VDC2A21• Battery charger-100-240V for
KANE100-1, AUTO4-1/5-1
CA10733/4• 12V charger
19278• 100-240v AC charger for KANE IRP-2
PSL/UK• UK power supply lead
Carry Cases
14102/2• Large carry bag
SM11816• Pro case
18
Accessories/Consumables
17820• Small carry bag
18704• Hard carry case
TO1233• Soft carry pouch for DM391 &
DM393C
Filters
PF2/10•Replacementfilterelementfor
AF2 (pack of ten). Suitable for in-line water traps on AUTO4-1/MID, AUTO5-1/MID, AUTO4-1, AUTO5-1, & AUTOplus4-2, AUTOplus5-2
PF400/5•Replacementfilterelement(packoffive).SuitableforKANE100, 501C, & 504
Paper & Ribbons
TP5• Pack of 5 thermal printer rolls
for Infra-Red Printer KANE IRP & KANE IRP-2
Water Traps
SM11629• Replacement in-line water
trap Suitable for AUTO4-1/MID, AUTO5-1/MID, AUTO4-1, AUTO5-1
SM13796• Replacement in-line water trap
for AUTOplus
SM12840• Replacement water trap for
AUTO7, 501C, 504
19
Distributed by:
® The KANE logo is a registered trademark of Kane International Ltd. All other marks are trademarks of their respective holders.
Follow us on...
Kane International LtdKane House, 11 Bessemer Road, Welwyn Garden City, Hertfordshire, AL7 1GF, UK
ServiceTel: +44 (0) 1707 384834 Fax: +44 (0) 1707 384833Email: [email protected]
SalesTel: +44 (0) 1707 384810 Fax: +44 (0) 1707 393277Email: [email protected]
www.kane.co.uk
Portable hand-held test instruments designed & manufactured in the UK for over 25 years
Global Quality & EnvironmentalKane is the only UK manufacturer of hand-held gas analysers to be granted UKAS accreditation to ISO/IEC 17025:2005 for its Welwyn Garden City calibration laboratory, covering a range of gases, temperature & pressure. Kane is certified to ISO9001 & ISO14001.
4448
Global References • Active Kane brand distribution network around the world
meeting the needs for pre-compliance testing, emission diagnostics & servicing.
• Leading pre-MOT gas analyser supplier in the UK.• Supplier to international regulated emission markets for
Cars and Motorcycles with handheld OIML Class 1 & MID compliant products.
• Supplier to several major OEMs operating in the Automotive Aftermarket for Tools & Equipment.
• Supplier to International Law Enforcement Agencies for mobile/ road side emission checking.
• Preferred gas analyser within the Fork Lift Truck, Motorcycle and “off the road” vehicle workshops.
• Preferred product for checking/ setting CO2 on parking heaters, auxiliary heaters & heating systems covering a variety of applications including automotive, marine, construction/ agriculture & rail.
• Leading supplier in the field of leak detection.
Kane International reserves the right to make changes to prices, products & specifications without prior notice. Kit contents may change, please check before purchase. Product images are not to scale unless stated & colours may vary from those illustrated.