Transcript
Page 1: Application 172 EN - KROHNEApplication 172 EN.indd 2 01.02.2010 15:52:18 Uhr Title Application 172 EN.indd Created Date 2/1/2010 3:52:10 PM

Mass flow measurement of pigment and plastic additives production.

•Constantqualitymonitoringduringproductionwithchangingviscosities•Bulkmassflowmeasurementrightdowntoprecisedosing•Automaticdosingofchemicalsinamixingtank

1. Background Oneoftheworld'sleadingmanufacturersofpigmentandplasticadditivesalsoproducesinGermany.Duringtheproductionoftheadditives,upto8chemicalswithviscositiesvaryingbetweenapprox.50and400mPa·sareaddedinsequencetoamixingtank.TheFlowratesrangefrom20000kg/hdowntolowflowdosingat500kg/h.

Productstobemeasuredinclude•Xylolwithextremelylowviscosity,•Bupolwithaviscosityofapprox.200mPa·s,and•Polyglycolwithahighviscosityofapprox.400mPa·s.

2. Measurement requirements

Tokeeppumpcapacitytoaminimum,onlymassflowmeterswithasinglestraightmeasuringtubeareused.Thechemicalsusedtomanufacturethepigmentandplasticadditivesarestoredintanks,andthenflowthroughthemassflowmeterstothemixers.Accuracymustremainconstantwithallchangesinviscosity.Themeasurementsmustberepeatable.Withtheautomatedprocess,themassflowmetersaddtheexactamountofchemicalstothemixers.Themetersmustbeself-draining,easytocleanandmaintenance-free.

APPLICATION NOTE Chemicals

Application 172 EN.indd 1 01.02.2010 15:52:16 Uhr

Page 2: Application 172 EN - KROHNEApplication 172 EN.indd 2 01.02.2010 15:52:18 Uhr Title Application 172 EN.indd Created Date 2/1/2010 3:52:10 PM

©KROHNE11/2009-172

-Su

bjecttoch

ange

with

outn

otice.

3. KROHNE Solution

Followingcomparativetestswithothersuppliers,KROHNEsuppliedmassflowmetersfromtheOPTIMASS7300Cseries,insizesT06,T10,T25andT40fortheseapplications.

Themetersmeasuretheprecisemassflowofthevariouschemicalsflowingtothemixers.Oncethedesiredquantityhasbeenreached,theinstrumentsstoptheflowtothemixers.

ThesinglestraightmeasuringtubeoftheOPTIMASS7300Ccompactmeters,togetherwiththeverticalmountingofthedevices,enablecompletedrainageofthemeasuringtubeswithoutresidue.

4. Customer advantages

TheKROHNEOPTIMASSflowmetersconsiderablyreducedthefillingtimeofthemixers.Inaddition,thefillingofthemixersnowstopsautomatically.Preciseadherencetothemixingratiosofthechemicalsincreasesthequalityofthecolourandpaintadditives.Thelong-termstabilityandexcellentreproducibilityoftheOPTIMASSmetersalsocontributestothis.

Theincreasedinaccuracywhenfillingthemixerswiththevariouschemicalsincreasesproductquality.Self-drainageandthelackofneedformaintenancealsoloweroperatingcosts.

5. Products used

OPTIMASS 7300 C • TheonlymassflowmeterwithonestraightmeasuringtubeavailableinStainlessSteel,Hastelloy®,TitaniumorTantalum

• Minimalpressureloss• Anymountingposition,easilydrainedandeasytoclean• Highaccuracyevenwhenproduct,viscosityand/ortemperaturechanges

• Reliablemassflowmeterforthemeasurementofmassflow,density,volume,temperature,massandvolume,concentrationaswellassolidcontent

Contact

PleasevisitourwebsiteforacurrentlistofallKROHNEcontactsandaddresses.