• Split - Sky Air • RZQSG-L3/9V1 1
• Outdoor Unit • RZQSG-L3/9V1
TABLE OF CONTENTSRZQSG-L3/9V1
1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Capacity and Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5 Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Cooling/Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Capacity Correction Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
8 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
9 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Piping Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Piping Diagram Twin Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Piping Diagram Triple Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Piping Diagram Double Twin Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
11 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Sound Power Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Sound Pressure Spectrum Quiet Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
12 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Installation Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
13 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
• Outdoor Unit • RZQSG-L3/9V1
1
2
1 Features
door Uni it - Sk SG-L3/9V1 r, Twin,
Out Spl RZQ Pai Technology and comfort combined for commercial applications• Top efficiency: - compressor that offers substantial efficiency improvements - control logic that optimises efficiency at the most frequently encountered operating conditions and that optimises the auxiliary modes (when the unit is not active) - heat exchangers that optimise the refrigerant flow at the most frequent operating conditions (temperature and load) - via improved nominal performances
• Re-use of existing R-22 or R-407C technology
• Guarantees operation in heating mode down to -15°C
• With gas cooled PCB reliable cooling is guaranteed as it is not influenced by ambient temperature (1~)
• Maximum piping length up to 50m, minimum piping length is 5m.
• Outdoor units for pair, twin, triple, double twin application
• Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall
• Compatibility with D-BACS
• Units optimized for seasonal efficiency give an indication on how efficient an air conditioner operates over an entire heating or cooling season.
Inverter Auto cooling-heating
changeover
• Split - Sky Air • RZQSG-L3/9V1
3
2
• Outdoor Unit • RZQSG-L3/9V1
2 Specifications
Notes
EER/COP according to Eurovent 2012, for use outside EU only
Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Notes
EER/COP according to Eurovent 2012, for use outside EU only
Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
2-1 Capacity and Power input FAQ71C/RZQSG71L3V1 FAQ100C/RZQSG100L9V1
Cooling capacity Nom. kW 6.8 9.5
Heating capacity Nom. kW 7.5 10.8
Power input Cooling Nom. kW 2.12 3.16
Heating Nom. kW 2.08 3.17
Seasonal efficiency (according to EN14825)
Cooling Energy label A+
Pdesign kW 6.80 9.50
SEER 6.05 5.61
Annual energy consumption
kWh 393 593
Heating (Average climate)
Energy label A A+
Pdesign kW 6.00 6.81
SCOP 3.90 4.01
Annual energy consumption
kWh 2,155 2,378
Nominal efficiency EER 3.21 3.01
COP 3.61 3.41
Annual energy consumption kWh 1,060 1,580
Energy label Cooling A B
Heating A B
2-2 Capacity and Power input FHQ71C/RZQSG71L3V1FHQ100C/
RZQSG100L9V1FHQ125C/
RZQSG125L9V1FHQ140C/
RZQSG140L9V1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4
Heating capacity Nom. kW 7.5 10.8 13.5 15.5
Power input Cooling Nom. kW 1.97 2.96 4.15 4.45
Heating Nom. kW 1.88 2.99 3.73 4.54
Seasonal efficiency (according to EN14825)
Cooling Energy label A+ -
Pdesign kW 6.80 9.50 12.00 -
SEER 5.61 -
Annual energy consumption
kWh 424 593 749 -
Heating (Average climate)
Energy label A A+ -
Pdesign kW 7.60 -
SCOP 3.90 3.91 4.01 -
Annual energy consumption
kWh 2,727 2,722 2,654 -
Nominal efficiency EER 3.46 3.21 2.89 3.01
COP 4.00 3.61 3.62 3.41
Annual energy consumption kWh 985 1,480 2,075 2,225
Energy label Cooling A C -
Heating A -
2-3 Capacity and Power input FCQG71F/RZQSG71L3V1FCQG100F/
RZQSG100L9V1FCQG125F/
RZQSG125L9V1FCQG140F/
RZQSG140L9V1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4
Heating capacity Nom. kW 7.5 10.8 13.5 15.5
Power input Cooling Nom. kW 2.12 2.88 3.74 4.45
Heating Nom. kW 2.08 3.05 3.96 4.54
• Split - Sky Air • RZQSG-L3/9V1 3
• Outdoor Unit • RZQSG-L3/9V1
2
4
2 Specifications
Notes
EER/COP according to Eurovent 2012, for use outside EU only
Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Notes
EER/COP according to Eurovent 2012, for use outside EU only
Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Seasonal efficiency (according to EN14825)
Cooling Energy label A++ A -
Pdesign kW 6.80 9.50 12.00 -
SEER 6.10 6.50 5.30 -
Annual energy consumption
kWh 390 512 793 -
Heating (Average climate)
Energy label A+ -
Pdesign kW 6.33 7.60 8.03 -
SCOP 4.10 4.01 -
Annual energy consumption
kWh 2,162 2,596 2,804 -
Nominal efficiency EER 3.21 3.30 3.21 3.01
COP 3.61 3.54 3.41
Annual energy consumption kWh 1,060 1,440 1,870 2,225
Energy label Cooling A -
Heating A B -
2-4 Capacity and Power inputFCQHG71F/
RZQSG71L3V1FCQHG100F/
RZQSG100L9V1FCQHG125F/
RZQSG125L9V1FCQHG140F/
RZQSG140L9V1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4
Heating capacity Nom. kW 7.5 10.8 13.5 15.5
Power input Cooling Nom. kW 1.94 2.57 3.71 4.17
Heating Nom. kW 1.83 2.51 3.60 4.29
Seasonal efficiency (according to EN14825)
Cooling Energy label A++ A -
Pdesign kW 6.80 9.50 12.00 -
SEER 6.50 6.70 5.40 -
Annual energy consumption
kWh 366 497 778 -
Heating (Average climate)
Energy label A+ -
Pdesign kW 7.60 8.03 -
SCOP 4.15 4.30 4.10 -
Annual energy consumption
kWh 2,563 2,615 2,742 -
Nominal efficiency EER 3.50 3.70 3.23 3.21
COP 4.10 4.30 3.75 3.61
Annual energy consumption kWh 970 1,285 1,855 2,085
Energy label Cooling A -
Heating A -
2-5 Capacity and Power input FVQ71C/RZQSG71L3V1FVQ100C/
RZQSG100L9V1FVQ125C/
RZQSG125L9V1FVQ140C/
RZQSG140L9V1
Cooling capacity Nom. kW 6.8 9.5 12.0 13.4
Heating capacity Nom. kW 7.5 10.8 13.5 15.5
Power input Cooling Nom. kW 2.12 2.96 4.27 4.45
Heating Nom. kW 2.08 2.99 3.96 4.54
2-3 Capacity and Power input FCQG71F/RZQSG71L3V1FCQG100F/
RZQSG100L9V1FCQG125F/
RZQSG125L9V1FCQG140F/
RZQSG140L9V1
• Split - Sky Air • RZQSG-L3/9V1
3
2
• Outdoor Unit • RZQSG-L3/9V1
2 Specifications
Notes
EER/COP according to Eurovent 2012, for use outside EU only
Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Notes
EER/COP according to Eurovent 2012, for use outside EU only
Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
Seasonal efficiency (according to EN14825)
Cooling Energy label A -
Pdesign kW 6.80 9.50 12.00 -
SEER 5.50 -
Annual energy consumption
kWh 433 605 764 -
Heating (Average climate)
Energy label A A+ A -
Pdesign kW 6.33 7.60 -
SCOP 3.86 4.01 3.85 -
Annual energy consumption
kWh 2,296 2,654 2,764 -
Nominal efficiency EER 3.21 2.81 3.01
COP 3.61 3.41
Annual energy consumption kWh 1,060 1,480 2,135 2,225
Energy label Cooling A -
Heating A B -
2-6 Capacity and Power input FDQ125C/RZQSG125L9V1
Cooling capacity Nom. kW 12.0
Heating capacity Nom. kW 13.5
Power input Cooling Nom. kW 3.74
Heating Nom. kW 3.85
Seasonal efficiency (according to EN14825)
Cooling Energy label A
Pdesign kW 12.00
SEER 5.20
Annual energy consumption
kWh 808
Heating (Average climate)
Energy label A
Pdesign kW 7.60
SCOP 3.90
Annual energy consumption
kWh 2,729
Nominal efficiency EER 3.21
COP 3.51
Annual energy consumption kWh 1,870
Energy label Cooling A
Heating B
2-7 Capacity and Power input FBQ71D/RZQSG71L3V1FBQ100D/
RZQSG100L9V1FBQ125D/
RZQSG125L9V1FBQ140D/
RZQSG140L9V1
Indoor unit FBQ71D FBQ100D FBQ125D FBQ140D
Outdoor unit RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1
Cooling capacity Nom. kW 6.8 (1) 9.5 (1) 12.0 (1) 13.4 (1)
Heating capacity Nom. kW 7.50 (1) 10.80 (1) 13.50 (1) 15.50 (1)
Power input Cooling Nom. kW 1.98 (1) 2.84 (1) 3.72 (1) 4.38 (1)
Heating Nom. kW 1.91 (1) 2.94 (1) 3.72 (1) 4.56 (1)
2-5 Capacity and Power input FVQ71C/RZQSG71L3V1FVQ100C/
RZQSG100L9V1FVQ125C/
RZQSG125L9V1FVQ140C/
RZQSG140L9V1
• Split - Sky Air • RZQSG-L3/9V1 5
• Outdoor Unit • RZQSG-L3/9V1
2
6
2 Specifications
Notes
(1) Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
(2) EER/COP according to Eurovent 2012, for use outside EU only
Seasonal efficiency (according to EN14825)
Cooling Energy label A+ A -
Pdesign kW 6.80 9.50 12.00 -
SEER 5.84 5.61 5.47 -
Annual energy consumption
kWh 408 593 768 -
Heating (Average climate)
Energy label A+ -
Pdesign kW 6.00 7.60 -
SCOP 4.01 4.15 4.01 -
Annual energy consumption
kWh 2,095 2,564 2,653 -
Nominal efficiency EER 3.43 (2) 3.35 (2) 3.23 (2) 3.06 (2)
COP 3.92 (2) 3.67 (2) 3.63 (2) 3.40 (2)
Annual energy consumption kWh 991 1,418 1,858 2,190
Energy label Cooling A -
Heating A -
2-8 Technical Specifications RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1
Capacity control Method Inverter controlled
Casing Colour Ivory white
Material Painted galvanized steel plate
Dimensions Unit Height mm 770 990 1,430
Width mm 900 940
Depth mm 320
Packed unit Height mm 900 1,170 1,610
Width mm 980 1,015
Depth mm 420 422
Weight Unit kg 67 72 74 95
Packed unit kg 71 81 83 104
Heat exchanger Fin Type WF fin
Treatment Anti-corrosion treatment (PE)
Compressor Quantity 1
Type Hermetically sealed swing compressor
Starting method Inverter driven
Fan Type Propeller fan
Discharge direction Horizontal
Quantity 1 2
Air flow rate Cooling Nom. m³/min 52 76 77.0 83
Super low
m³/min -
cfm -
Heating Nom. m³/min 48 83 62
Super low
m³/min -
cfm -
Fan motor Quantity 1 2
Model KFD-325-70-8A Brushless DC motor
Output W 70 200 94
Drive Direct drive
Speed Cooling Super low
rpm -
Heating Super low
rpm -
Sound power level Cooling dBA 65 70 69
Heating dBA -
2-7 Capacity and Power input FBQ71D/RZQSG71L3V1FBQ100D/
RZQSG100L9V1FBQ125D/
RZQSG125L9V1FBQ140D/
RZQSG140L9V1
• Split - Sky Air • RZQSG-L3/9V1
3
2
• Outdoor Unit • RZQSG-L3/9V1
2 Specifications
Sound pressure level Cooling Nom. dBA 49 53 54 53
Silent operation dBA 47 -
Heating Nom. dBA 51 57 58 54
Night quiet mode Level 1 dBA - 49
Operation range Cooling Ambient
Min. °CDB -15.0
Max. °CDB 46
Heating Ambient
Min. °CWB -15
Max. °CWB 15.5
Refrigerant Type R-410A
Charge kg 2.75 2.9 4.0
TCO2eq 5.7 6.1 8.4
Control Expansion valve (electronic type)
GWP 2,087.5
Circuits Quantity 1
Refrigerant oil Type FVC50K
Charged volume l 0.75 0.9 1.35
Piping connections Liquid Quantity 1
Type Flare connection
OD mm 9.52
Gas Quantity 1
Type Flare connection
OD mm 15.9
Drain Quantity 3 5
Type Hole
ID mm -
OD mm 26
Piping length OU - IU Min. m 5
Max. m 50
System Equivalent
m 70
Chargeless
m 30
Additional refrigerant charge kg/m See installation manual
Level difference IU - OU Max. m 15 30.0
IU - IU Max. m 0.5
Heat insulation Both liquid and gas pipes
Defrost method Pressure equalising Reversed cycle
Defrost control Sensor for outdoor heat exchanger temperature
Safety devices Item 01 High pressure switch
02 Fan motor thermal protection
Low pressure switch
03 Fuse Fan driver overload protector
04 - Fuse
2-9 Electrical Specifications RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1
Power supply Name V1
Phase 1~
Frequency Hz 50
Voltage V 220-240
Voltage range Min. % -10
Max. % 10
Current Zmax List - Complies to EN61000-3-11
A Recommended fuses
25 40
Current - 50Hz Maximum fuse amps (MFA) A 20 -
Current - 60Hz Maximum fuse amps (MFA) A -
Wiring connections For power supply Remark See installation manual outdoor unit
For connection with indoor
Remark See installation manual outdoor unit
Power supply intake Outdoor unit only
2-8 Technical Specifications RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1
• Split - Sky Air • RZQSG-L3/9V1 7
• Outdoor Unit • RZQSG-L3/9V1
2
8
2 Specifications
Notes
Minimum Ssc (=Short-circuit power) value: Equipment complying with EN/IEC 61000-3-12: European/International Technical Standard setting the limits for harmonic currents produced
by equipment connected to public low-voltage systems with input current \>16A and ≤ 75A per phase
See separate drawing for electrical data
European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A
and ≤ 75A per phase.
Short-circuit power
Contains fluorinated greenhouse gases
PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC
• Split - Sky Air • RZQSG-L3/9V1
3
3
• Outdoor Unit • RZQSG-L3/9V1
3 Electrical data3 - 1 Electrical Data
• Split - Sky Air • RZQSG-L3/9V1 9
• Outdoor Unit • RZQSG-L3/9V1
3
10
3 Electrical data3 - 1 Electrical Data
• Split - Sky Air • RZQSG-L3/9V1
3
3
• Outdoor Unit • RZQSG-L3/9V1
3 Electrical data3 - 1 Electrical Data
1 2 3 MCA MFA RHz RLA kW FLA kW FLA
OFMIFMFLAkWRHz
COMP
MCAMFARLA
234
1
COMP OFM IFM
Voltage rangeVoltageHz
OutdoorIndoor
Unit combination restrictions Power supply
Symbols
Minimum Circuit Ampere (A)Maximum Fuse Ampere (A)Rated load amps [A]
Outdoor fan motorIndoor fan motorFull Load Ampere (A)Fan motor rated output [kW]
Notes
The RLA is based on the following conditions.Indoor temperature 27°C DB / 19°C WBOutdoor temperature 35°C DBSelect the wire size according to the MCA.
Use a circuit breaker instead of a fuse.
Rated operating frequency [Hz]
The maximum allowable voltage that is unbalanced between phases is 2%.
Compressor
RZQSG71 125L3/9V1
3D094863B
• Split - Sky Air • RZQSG-L3/9V1 11
• Outdoor Unit • RZQSG-L3/9V1
3
12
3 Electrical data3 - 1 Electrical Data
1 2 3 MCA MFA RHz RLA kW FLA kW FLA
OFMIFMFLAkWRHz
COMP
MCAMFARLA
234
1
COMP OFM IFM
Voltage rangeVoltageHz
OutdoorIndoor
Unit combination restrictions Power supply
Symbols
Minimum Circuit Ampere (A)Maximum Fuse Ampere (A)Rated load amps [A]
Outdoor fan motorIndoor fan motorFull Load Ampere (A)Fan motor rated output [kW]
Notes
The RLA is based on the following conditions.Indoor temperature 27°C DB / 19°C WBOutdoor temperature 35°C DBSelect the wire size according to the MCA.
Use a circuit breaker instead of a fuse.
Rated operating frequency [Hz]
The maximum allowable voltage that is unbalanced between phases is 2%.
Compressor
RZQSG125 140L9V1
3D094863B
1 2 3 MCA MFA RHz RLA kW FLA kW FLA
OFMIFMFLAkWRHz
COMPRLA
MCAMFA
1
234
COMP OFM IFM
Voltage rangeVoltageHz
OutdoorIndoor
Unit combination restrictions Power supply
Symbols
Minimum Circuit Ampere (A)Maximum Fuse Ampere (A)Rated load amps [A]
Outdoor fan motorIndoor fan motorFull Load Ampere (A)Fan motor rated output [kW]
Notes
The RLA is based on the following conditions.Indoor temperature 27°C DB / 19°C WBOutdoor temperature 35°C DBSelect the wire size according to the MCA.
Use a circuit breaker instead of a fuse.
Rated operating frequency [Hz]
The maximum allowable voltage that is unbalanced between phases is 2%.
Compressor
RZQSG L3/9V1
3D096315C
• Split - Sky Air • RZQSG-L3/9V1
3
4
• Outdoor Unit • RZQSG-L3/9V1
4 Options4 - 1 Options
RZQSG L3/9V1
Available options for RZQSG models
RZQSG71L3V1B RZQSG100L9V1B RZQSG125L9V1B RZQSG140L9V1BBottom plate heater
TwinTripleDouble twin
Demand adaptor kit KRP58M51
Refrigerant branch piping KHRQ22M20TAKHRQ127H
KHRQ22M20TA (3x)SB.KRP58M51
OptionOption kit
3D090356A
• Split - Sky Air • RZQSG-L3/9V1 13
• Outdoor Unit • RZQSG-L3/9V1
5
14
5 Combination table5 - 1 Combination Table
RZQSG L3/9V1RZQSG L(8)Y1
Possible combinations P= Pair2= Twin3= Triple4= Double twin
(*): Maximum capacity of outdoor units
Sky AirDuct (high ESP)
FCQH
G71F
VEB
FCQH
G100
FVEB
FCQH
G125
FVEB
FCQH
G140
FVEB
FCQG
35FV
EB
FCQG
50FV
EB
FCQG
60FV
EB
FCQG
71FV
EB
FCQG
100F
VEB
FCQG
125F
VEB
FCQG
140F
VEB
FFQ3
5C2V
EB
FFQ5
0C2V
EB
FFQ6
0C2V
EB
FBQ3
5C8V
EB
FBQ5
0C8V
EB
FBQ6
0C8V
EB
FBQ7
1C8V
EB
FBQ1
00C8
VEB
FBQ1
25C8
VEB
FBQ1
40C8
VEB
FHQ3
5BVV
1B8
FHQ5
0BVV
1B8
FHQ6
0BVV
1B8
FHQG
71CV
EB
FHQG
100C
VEB
FHQG
125C
VEB
FHQG
140C
VEB
FUQ7
1CVE
B
FUQ1
00CV
EB
FUQ1
25CV
EB
FAQ7
1CVE
B
FAQ1
00CV
EB
FDQ1
25C7
VEB
FVQ7
1CVE
B
FVQ1
00CV
EB
FVQ1
25CV
EB
FVQ1
40CV
EB
FDXS
35F2
VEB
FDXS
50F2
VEB9
FDXS
60F2
VEB
RZQSG71L3V1B P 2 P 2 2 P 2 P P P 2RZQSG100L9V1B RZQSG100L8Y1B P 3 2 P 3 2 3 2 P 3 2 P P P 3 2RZQSG125L9V1B RZQSG125L8Y1B P 4 3 2 P 4 3 2 4 3 2 P 4 3 2 P P P 4 3 2RZQSG140L9V1B RZQSG140L7Y1B 2 P 4 3 2 P 4 3 4 3 2 P 4 3 2 P 2 P 4 3
Sky Air
FBQ3
5D2V
EB
FBQ5
0D2V
EB
FBQ6
0D2V
EB
FBQ7
1D2V
EB
FBQ1
00D2
VEB
FBQ1
25D2
VEB
FBQ1
40D2
VEB
FNQ2
5A2V
EB
FNQ3
5A2V
EB
FNQ5
0A2V
EB
FNQ6
0A2V
EB
2 P 23 2 P 3 24 3 2 P 4 3 24 3 2 P 4 3
Notes
1. The capacities in the table are combined capacities (multiple units operating simultaneously) and not individual indoor unit capacities.2. When combining multiple indoor units, designate the unit whose remote controller is equipped with the most functions as the master unit.3. For the selection of the correct refnet kit, required to install a multi-combination, refer to the option list.
Twin : ·KHRQ22M20TA· or ·KHRQ58T·Triple : ·KHRQ127H· or ·KHRQ58H·
Double twin : ·KHRQ22M20TA· or ·KHRQ58T·
RZQSG140L9V1B RZQSG140L7Y1B
Model
RZQSG71L3V1BRZQSG100L9V1B RZQSG100L8Y1BRZQSG125L9V1B RZQSG125L8Y1B
Wall mounted
typeFloor standing type Slim duct
Model
Duct (medium ESP) Concealed floor standing type
High Cassette Thin cassette 2x2 cassette Duct (medium ESP) Ceiling-suspended Ceiling-mounted - 4-way blow
35+35+35 50+50+50 (*) 50+50+50 (*)35+35+35+35 (*) 35+35+35+35
71 100 125 14035+35 50+50 60+60 71+71
3D090361B
• Split - Sky Air • RZQSG-L3/9V1
3
5
• Outdoor Unit • RZQSG-L3/9V1
5 Combination table5 - 1 Combination Table
• Split - Sky Air • RZQSG-L3/9V1 15
• Outdoor Unit • RZQSG-L3/9V1
6
16
6 Capacity tables6 - 1 Cooling/Heating Capacity Tables
• Split - Sky Air • RZQSG-L3/9V1
3
6
• Outdoor Unit • RZQSG-L3/9V1
6 Capacity tables6 - 1 Cooling/Heating Capacity Tables
RZQSG100L9V1RZQSG100L8Y1
Cooling Heating
SymbolsAFR: Air flow rate [m³/min]BF: Bypass factor
EWB: Entering wet bulb temperature (°C WB)EDB: Entering dry bulb temperature (°C DB)TC: Maximum total cooling/heating capacity [kW]
SHC: Sensible heat capacity [kW]CPI: Coefficient of the power inputPI: Power input [kW]
compressor + indoor and outdoor fan motors
Cooling Heating
Notes1. The ratings shown are net capacities which include a deduction for indoor fan motor heat.2. = Maximum at standard conditions
= Rated capacity and rated coefficient of the power inputThe maximum capacity is not guaranteed except at standard conditions.
3. SHC is based on indoor units EWB & EDB.SHC for other dry bulb temperatures = SHC + SHC*SHC* = SHC correction for other dry bulb temperatures
= 0.02 x AFR (m³/min) x (1 BF) x (DB* EDB)4. The capacities are based on the following conditions:
Outdoor air: 85% RHHowever, the outdoor ambient condition of the rated capacity during heating operation is 7°C DB / 6°C WB.Corresponding refrigerant piping length: 5.0 mLevel difference: 0m
5. CPI is a percentage value compared to the rated value which is 1.00.6. The error rate for this value is less than 5% and depends on the indoor unit type.7. The heating performance takes into account the drop that occurs during defrost operation.8. The air flow rate and bypass factor are mentioned in the table. 9. The rated power input for each model is mentioned in the table below.
Pair PairFCQGH100F FCQG100F FBQ100C FHQG100C FAQ100C FVQ100C FHQ100CA FBQ100D FCQGH100F FCQG100F FBQ100C FHQG100C FAQ100C FVQ100C FHQ100CA FBQ100D
Cooling 2,57 2,88 2,87 2,96 3,16 2,96 2,96 2,84
Heating 2,51 3,05 2,96 2,99 3,17 2,99 2,99 2,94
Twin Twin
FCQG50F X 2 FBQ50C X 2 FHQ50CA X 2 FFQ50C X 2 FDXS50F9 X 2 FBQ50D X 2 FNQ50A X 2 FCQG50F X 2 FBQ50C X 2 FHQ50CA X 2 FFQ50C X 2 FDXS50F9 X 2 FBQ50D X 2 FNQ50A X 2
Cooling 2,76 2,93 3,35 3,13 3,15 3,10 3,15
Heating 2,61 2,86 3,28 3,34 3,31 3,27 3,31
Triple Triple
FCQG35F X 3 FBQ35C X 3 FHQ35CA X 3 FFQ35C X 3 FDXS35F X 3 FBQ35D X 3 FNQ35A X 3 FCQG35F X 3 FBQ35C X 3 FHQ35CA X 3 FFQ35C X 3 FDXS35F X 3 FBQ35D X 3 FNQ35A X 3
Cooling 2,82 2,93 3,33 2,88 3,71 2,90 3,71
Heating 2,66 2,86 3,26 3,04 4,06 3,24 4,06
8.7 x 3(0.17 x 3)
15 x 3(0.08 x 3)
8.7 x 3(0.17 x 3)
18 x 2(0.15 x 2)
16 x 2(0.11 x 2)
AFR(BF)
12.5 x 3(0.4 x 3)
16 x3(0.15 x 3)
14 x 3(0.17 x 3)
10 x 3(0.25 x 3)
AFR(BF)
12.6 x 2(0.22 x 2)
16 x2(0.16 x 2)
15 x 2(0.18 x 2)
12 x 2(0.16 x 2)
16 x 2(0.11 x 2)
26.0(0.10)
28.0(0.20)
28.0(0.09)
29.0(0.03)
AFR(BF)
32.3(0.17)
32.0(0.17)
32.0(0.13)
20.0(0.09)
Coefficient
ofthepo
wer
inpu
t
Coefficient
ofthepo
wer
inpu
t
Cooling capacity [kW] Heating capacity [kW]
Capacity rangeRated point
Rated point
Indoor
Indo
or
Outdoor temperature [°C DB] Outdoor temperature [°C WB]
Capacity range
3D076753E
RZQSG125L9V1RZQSG125L8Y1
Cooling Heating
SymbolsAFR: Air flow rate [m³/min]BF: Bypass factor
EWB: Entering wet bulb temperature (°C WB)EDB: Entering dry bulb temperature (°C DB)TC: Maximum total cooling/heating capacity [kW]
SHC: Sensible heat capacity [kW]CPI: Coefficient of the power inputPI: Power input [kW]
compressor + indoor and outdoor fan motors
Cooling Heating
Notes1. The ratings shown are net capacities which include a deduction for indoor fan motor heat.2. = Maximum at standard conditions
= Rated capacity and rated coefficient of the power inputThe maximum capacity is not guaranteed except at standard conditions.
3. SHC is based on indoor units EWB & EDB.SHC for other dry bulb temperatures = SHC + SHC*SHC* = SHC correction for other dry bulb temperatures
= 0.02 x AFR (m³/min) x (1 BF) x (DB* EDB)4. The capacities are based on the following conditions:
Outdoor air: 85% RHHowever, the outdoor ambient condition of the rated capacity during heating operation is 7°C DB / 6°C WB.Corresponding refrigerant piping length: 5.0 mLevel difference: 0m
5. CPI is a percentage value compared to the rated value which is 1.00.6. The error rate for this value is less than 5% and depends on the indoor unit type.7. The heating performance takes into account the drop that occurs during defrost operation.8. The air flow rate and bypass factor are mentioned in the table. 9. The rated power input for each model is mentioned in the table below.
Pair Pair
FCQHG125F FCQG125F FBQ125C FHQG125C FAQ125C FVQ125C FHQ125CA FBQ125D FCQHG125F FCQG125F FBQ125C FHQG125C FAQ125C FVQ125C FHQ125CA FBQ125D
Cooling 3,71 3,74 3,74 4,15 3,74 4,27 4,15 3,72
Heating 3,60 3,96 3,85 3,73 3,85 3,96 3,73 3,72
Twin Twin
FCQG60F X 2 FBQ60C X 2 FHQ60CA X 2 FFQ60C X 2 FDXS60F X 2 FBQ60D X 2 FNQ60A X 2 FCQG60F X 2 FBQ60C X 2 FHQ60CA X 2 FFQ60C X 2 FDXS60F X 2 FBQ60D X 2 FNQ60A X 2
Cooling 3,66 3,95 4,34 4,75 4,88 4,24 4,88
Heating 3,88 4,06 4,43 4,33 4,38 4,14 4,38
Triple Triple
FCQG50F X 3 FBQ50C X 3 FHQ50CA X 3 FFQ50C X 3 FDXS50F9 X 3 FBQ50D X 3 FNQ50A X 3 FCQG50F X 3 FBQ50C X 3 FHQ50CA X 3 FFQ50C X 3 FDXS50F9 X 3 FBQ50D X 3 FNQ50A X 3
Cooling 3,69 3,95 4,33 4,14 4,07 4,08 4,07
Heating 3,90 4,06 4,42 3,87 3,92 4,09 3,92
Double twin Double twin
FCQG35F X 4 FBQ35C X 4 FHQ35CA X 4 FFQ35C X 4 FDXS35F X 4 FBQ35D X 4 FNQ35A X 4 FCQG35F X 4 FBQ35C X 4 FHQ35CA X 4 FFQ35C X 4 FDXS35F X 4 FBQ35D X 4 FNQ35A X 4
Cooling 3,75 3,95 4,31 3,99 4,67 3,95 4,67
Heating 3,96 4,06 4,32 3,59 4,66 4,03 4,66
15 x 4(0.08 x 4)
8.7 x 4(0.17 x 4)
AFR(BF)
12.5 x 4(0.4 x 4)
16 x4(0.15 x 4)
14 x 4(0.17 x 4)
10 x 4(0.25 x 4)
8.7 x 4(0.17 x 4)
16 x 3(0.11 x 3)
15 x 3(0.13 x 3)
16 x 3(0.11 x 3)
18 x 2(0.15 x 2)
16 x 2(0.12 x 2)
AFR(BF)
12.6 x 3(0.22 x 3)
16 x 3(0.16 x 3)
15 x 3(0.18 x 3)
12 x 3(0.16 x 3)
AFR(BF)
13.6 x 2(0.2 x 2)
18 x 2(0.15 x 2)
19.5 x 2(0.20 x 2)
14.5 x 2(0.11 x 2)
16 x 2(0.12 x 2)
39.0(0.16)
28.0(0.16)
31.0(0.14)
34.0(0.06)
AFR(BF)
33.5(0.19)
33.0(0.21)
39.0(0.16)
31.0(0.134)
Coefficient
ofthepo
wer
inpu
t
Coefficient
ofthepo
wer
inpu
t
Cooling capacity [kW] Heating capacity [kW]
Capacity range
Rated pointCapacity range
Rated point
Indoor
Indo
or
Outdoor temperature [°C DB] Outdoor temperature [°C WB]
3D076754F
• Split - Sky Air • RZQSG-L3/9V1 17
• Outdoor Unit • RZQSG-L3/9V1
6
18
6 Capacity tables6 - 1 Cooling/Heating Capacity Tables
RZQSG140L9V1RZQSG140LY1
Cooling Heating
SymbolsAFR: Air flow rate [m³/min]BF: Bypass factor
EWB: Entering wet bulb temperature (°C WB)EDB: Entering dry bulb temperature (°C DB)TC: Maximum total cooling/heating capacity [kW]
SHC: Sensible heat capacity [kW]CPI: Coefficient of the power inputPI: Power input [kW]
compressor + indoor and outdoor fan motors
Cooling Heating
Notes1. The ratings shown are net capacities which include a deduction for indoor fan motor heat.2. = Maximum at standard conditions
= Rated capacity and rated coefficient of the power inputThe maximum capacity is not guaranteed except at standard conditions.
3. SHC is based on indoor units EWB & EDB.SHC for other dry bulb temperatures = SHC + SHC*SHC* = SHC correction for other dry bulb temperatures
= 0.02 x AFR (m³/min) x (1 BF) x (DB* EDB)4. The capacities are based on the following conditions:
Outdoor air: 85% RHHowever, the outdoor ambient condition of the rated capacity during heating operation is 7°C DB / 6°C WB.Corresponding refrigerant piping length: 5.0 mLevel difference: 0m
5. CPI is a percentage value compared to the rated value which is 1.00.6. The error rate for this value is less than 5% and depends on the indoor unit type.7. The heating performance takes into account the drop that occurs during defrost operation.8. The air flow rate and bypass factor are mentioned in the table. 9. The rated power input for each model is mentioned in the table below.
Pair Pair
FCQHG140F FCQG140F FBQ140C FHQG140C FVQ140C FHQ140CA FBQ140D FCQHG140F FCQG140F FBQ140C FHQG140C FVQ140C FHQ140CA FBQ140D
Cooling 4,17 4,45 4,44 4,45 4,45 4,45 4,38
Heating 4,29 4,54 4,54 4,54 4,54 4,54 4,56
Twin Twin
FCQHG71F X 2 FCQG71F X 2 FBQ71C X 2 FHQG71C X 2 FAQ71C X 2 FHQ71CA X 2 FBQ71D X 2 FCQHG71F X 2 FCQG71F X 2 FBQ71C X 2 FHQG71C X 2 FAQ71C X 2 FHQ71CA X 2 FBQ71D X 2
Cooling 4,11 4,39 4,17 4,01 4,23 4,01 4,17
Heating 4,23 4,48 4,94 4,71 4,92 4,71 4,94
Triple Triple
FCQG50F X 3 FBQ50C X 3 FHQ50CA X 3 FFQ50C X 3 FDXS50F9 X 3 FBQ50D X 3 FNQ50A X 3 FCQG50F X 3 FBQ50C X 3 FHQ50CA X 3 FFQ50C X 3 FDXS50F9 X 3 FBQ50D X 3 FNQ50A X 3
Cooling 4,40 4,17 4,67 4,43 4,68 4,17 4,68
Heating 4,48 4,94 5,67 4,39 4,61 4,94 4,61
Double twin Double twin
FCQG35F X 4 FBQ35C X 4 FHQ35CA X 4 FFQ35C X 4 FDXS35F X 4 FBQ35D X 4 FNQ35A X 4 FCQG35F X 4 FBQ35C X 4 FHQ35CA X 4 FFQ35C X 4 FDXS35F X 4 FBQ35D X 4 FNQ35A X 4
Cooling 4,56 4,17 4,65 4,11 5,80 4,17 5,80
Heating 4,54 4,94 5,57 4,05 6,09 4,94 6,09
15 x 4(0.08 x 4)
8.7 x 4(0.17 x 4)
AFR(BF)
12.5 x 4(0.4 x 4)
16 x4(0.15 x 4)
14 x 4(0.20 x 4)
10 x 4(0.25 x 4)
8.7 x 4(0.17 x 4)
16 x 3(0.11 x 3)
15 x 3(0.13 x 3)
16 x 3(0.11 x 3)
20.5 x 2(0.13 x 2)
18 x 2(0.13 x 2)
AFR(BF)
12.6 x 3(0.22 x 3)
16 x 3(0.16 x 3)
15 x 3(0.18 x 3)
12 x 3(0.16 x 3)
AFR(BF)
21.2 x 2(0.2 x2)
21.5 x 2(0.14 x 2)
18.0 x 2(0.08 x 2)
20.5 x 2(0.13 x 2)
18.0 x 2(0.16 x 2)
30.0(0.18)
34.0(0.17)
34.0(0.06)
AFR(BF)
33.5(0.15)
33.0(0.23)
39:C/41:H(0.14)
34.0(0.17)
Coefficient
ofthepo
wer
inpu
t
Coefficient
ofthepo
wer
inpu
t
Cooling capacity [kW] Heating capacity [kW]
Capacity rangeRated point
Capacity range
Rated point
Indoor
Indo
or
Outdoor temperature [°C DB] Outdoor temperature [°C WB]
3D076755E
• Split - Sky Air • RZQSG-L3/9V1
3
6
• Outdoor Unit • RZQSG-L3/9V1
6 Capacity tables6 - 2 Capacity Correction Factor
10095908580757065605550454035302520150 5 1060
65
70
75
80
85
90
95
100RZQSG71~140
RZQSG71
RZQSG100
RZQSG125
RZQSG140
7.5m
97.7%
90%
84.3%
80.2%
95%
RZQSG100-140L9V1
3D076247A
• Split - Sky Air • RZQSG-L3/9V1 19
• Outdoor Unit • RZQSG-L3/9V1
7
20
7 Dimensional drawings7 - 1 Dimensional Drawings
• Split - Sky Air • RZQSG-L3/9V1
3
7
• Outdoor Unit • RZQSG-L3/9V1
7 Dimensional drawings7 - 1 Dimensional Drawings
• Split - Sky Air • RZQSG-L3/9V1 21
• Outdoor Unit • RZQSG-L3/9V1
8
22
8 Centre of gravity8 - 1 Centre of Gravity
• Split - Sky Air • RZQSG-L3/9V1
3
8
• Outdoor Unit • RZQSG-L3/9V1
8 Centre of gravity8 - 1 Centre of Gravity
• Split - Sky Air • RZQSG-L3/9V1 23
• Outdoor Unit • RZQSG-L3/9V1
8
24
8 Centre of gravity8 - 1 Centre of Gravity
• Split - Sky Air • RZQSG-L3/9V1
3
9
• Outdoor Unit • RZQSG-L3/9V1
9 Piping diagrams9 - 1 Piping Diagrams
• Split - Sky Air • RZQSG-L3/9V1 25
• Outdoor Unit • RZQSG-L3/9V1
9
26
9 Piping diagrams9 - 2 Piping Diagram Twin Application
• Split - Sky Air • RZQSG-L3/9V1
3
9
• Outdoor Unit • RZQSG-L3/9V1
9 Piping diagrams9 - 3 Piping Diagram Triple Application
• Split - Sky Air • RZQSG-L3/9V1 27
• Outdoor Unit • RZQSG-L3/9V1
9
28
9 Piping diagrams9 - 4 Piping Diagram Double Twin Application
• Split - Sky Air • RZQSG-L3/9V1
3
10
• Outdoor Unit • RZQSG-L3/9V1
10 Wiring diagrams10 - 1 Wiring Diagrams - Single Phase
R6K15RTC
RCK10R K11M
+ C1V3D
V1T X25A
PSK13R
X804A
X806A
X805A
X106A
M1FMS
HAP
H1P H3P H5P H7P
H2P H4P H6P
BS1 BS2 BS3 BS4
ONDS1
21OFF
X11A X12A
R3T
t°
R1T
t°
X13A
R6T
t°
R2T
t°
R4T
t°
R5T
t°
M
S1PHP>
S1PLP<
K1R
Y1S
A2P
A1P
W
VU
X31AX32A
X21A
Y1E
C2
C3
A1PL1R
X1M
HAP
X6A
6
V2R
N
220-240V1N 50Hz
L
NA
L N
LARED BLU
X803A
2 31
Z3CN=1
X1MX1M
Q1DI
F2UF1U
Z1F
Z3F
E1
Z2F
V2TV2D
+ -HR1
HR3
L1R
HR4
HR2
Z5C
N=6
V1R
WV
RED
~
Z4CN=4
U
WHT
V W
U
3MS
BLU
M1C
F6UR2
R4
+ -
V1D
R5
+t°
R8T
X6A
X77A
X28A
X5A
8
X205A
A2P
R7T+t°
WHT
BRN
PPL
RED
Z2CN=3
Z6C
N=1Z1
CN=
5
BLK
WH
TR
ED
K14RK2R
GRN/YLW
GRN
X502A
SEENOTE 7
RZQSG100L9V1
2D089497B
• Split - Sky Air • RZQSG-L3/9V1 29
• Outdoor Unit • RZQSG-L3/9V1
10
30
10 Wiring diagrams10 - 1 Wiring Diagrams - Single Phase
N
220-240V1N 50Hz
L
NA
L N
LAF2U F1U
Z1F
Z1C
N=2
Z6C
N=1
RED BLU
GRN/YLW
Z4F
F4U
Z3F
X803A
R3K15R TC RC
K14R
R4
Z2F
F3U
X98A
NCLC
E2
X802AE3
X99A
RED BLU GRNZ3C
N=2
NBLB
X801A
Z5C
N=1
R1
Z6F
K10RK11M
L3RL2RL1R
+ C1V3DV2DV1D
V2TV1T
V3T
X25A X28A
R5PS
K13R V4D
X804A
X806A
X805A
F6UR2
+ -V1R
WV
RED
~
Z4CN=6
U
WHT
V W
U
3MS
BLU
M1C
E1
X106A
M1FMS
HAP
H1P H3P H5P H7P
H2P H4P H6P
BS1 BS2 BS3 BS4ON
DS1
21OFF
X111A
R7T
t°
X11A X12A
R3T
t°
R1T
t°
X13A
R6T
t°
R2T
t°
R4T
t°
R5T
t° M
S1PHP>
S1PLP<
GRN
K1R K4R
Y1S
A2P
A1P
W
VU
2 31 Z2CN=2
X1MX1M
X31A
X32A
X21AY1E
C3
C2
A1P
A2P
X1M
HAP
X77AX6A
6
Q1DI
V2R
BLK
BLU
RE
D
Z5F
X502A
GRN
SEE NOTE 7
RZQSG125L9V1
2D089489B
N
220-240V1N 50Hz
L
NA
L N
LAF2U F1U
Z1F
Z1C
N=2
Z6C
N=1
RED BLU
GRN/YLW
Z4F
F4U
Z3F
X803A
R3K15R TC RC
K14R
R4
Z2F
F3U
X98A
NCLC
E2
X802AE3
X99A
RED BLU GRNZ3C
N=2
NBLB
X801A
Z5C
N=1
R1
Z6F
K10RK11M
L3RL2RL1R
+ C1V3DV2DV1D
V2TV1T
V3T
X25A X28A
R5PS
K13R V4D
X804A
X806A
X805A
F6UR2
+ -V1R
WV
RED
~
Z4CN=6
U
WHT
V W
U
3MS
BLU
M1C
E1
X107A
M2FMS
X106A
M1FMS
HAP
H1P H3P H5P H7P
H2P H4P H6P
BS1 BS2 BS3 BS4ON
DS1
21OFF
X111A
R7T
t°
X11A X12A
R3T
t°
R1T
t°
X13A
R6T
t°
R2T
t°
R4T
t°
R5T
t° M
S1PHP>
S1PLP<
GRN
K1R K4R
Y1S
A2P
A1P
W
VU
2 31 Z2CN=2
X1MX1M
X31A
X32A
X21AY1E
C3
C2
A1P
A2P
X1M
HAP
X77AX6A
6
Q1DI
V2R
BLK
BLU
RE
D
Z5F
X502A
GRN
SEE NOTE 7
SEE NOTE 7
RZQSG140L9V1
2D088865C
• Split - Sky Air • RZQSG-L3/9V1
3
11
• Outdoor Unit • RZQSG-L3/9V1
11 Sound data11 - 1 Sound Power Spectrum
����������
������ ����� ���������������� ������������������������������������ �� ������������������������!�"����#"��$%&'()� *����������������������+,�-.//
NR0
NR5 NR10 NR15 NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
NR80
NR85
NR90
10
20
30
40
50
60
70
80
90
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
� �����
• Split - Sky Air • RZQSG-L3/9V1 31
• Outdoor Unit • RZQSG-L3/9V1
11
32
11 Sound data11 - 1 Sound Power Spectrum
����������
������ ����� ���������������� ������������������������������������ �� ������������������������!�"����#"��$%&'()� *����������������������+,�-.//
NR0
NR5 NR10 NR15 NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
NR80
NR85
NR90
10
20
30
40
50
60
70
80
90
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
� �����
����������
������ ����� ���������������� ������������������������������������ �� ������������������������!�"����#"��$%&'()� *����������������������+,�-.//
NR0
NR5 NR10 NR15 NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
NR80
NR85
NR90
10
20
30
40
50
60
70
80
90
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
� �����
• Split - Sky Air • RZQSG-L3/9V1
3
11
• Outdoor Unit • RZQSG-L3/9V1
11 Sound data11 - 2 Sound Pressure Spectrum - Cooling
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
• Split - Sky Air • RZQSG-L3/9V1 33
• Outdoor Unit • RZQSG-L3/9V1
11
34
11 Sound data11 - 2 Sound Pressure Spectrum - Cooling
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
• Split - Sky Air • RZQSG-L3/9V1
3
11
• Outdoor Unit • RZQSG-L3/9V1
11 Sound data11 - 3 Sound Pressure Spectrum - Heating
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
• Split - Sky Air • RZQSG-L3/9V1 35
• Outdoor Unit • RZQSG-L3/9V1
11
36
11 Sound data11 - 3 Sound Pressure Spectrum - Heating
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
• Split - Sky Air • RZQSG-L3/9V1
3
11
• Outdoor Unit • RZQSG-L3/9V1
11 Sound data11 - 4 Sound Pressure Spectrum Quiet Mode
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
• Split - Sky Air • RZQSG-L3/9V1 37
• Outdoor Unit • RZQSG-L3/9V1
11
38
11 Sound data11 - 4 Sound Pressure Spectrum Quiet Mode
����������
������ 0���������������� ���� ���������������� 0������������������(�������������������������� ����� �������������������������������������������������������� �� �������������������������"�����1"�%2�
NR0 NR5 NR10 NR15
NR20
NR25
NR30
NR35
NR40
NR45
NR50
NR55
NR60
NR65
NR70
NR75
10
20
30
40
50
60
70
10
15
20
25
30
35
40
45
50
55
60
65
70
63 125 250 500 1000 2000 4000 8000 dBA
So
un
d p
ress
ure
leve
l [d
B]
Octave band centre frequency [Hz]
*����������������������������������
� �����
• Split - Sky Air • RZQSG-L3/9V1
3
12
• Outdoor Unit • RZQSG-L3/9V1
12 Installation12 - 1 Installation Method
• Split - Sky Air • RZQSG-L3/9V1 39
• Outdoor Unit • RZQSG-L3/9V1
12
40
12 Installation12 - 1 Installation Method
• Split - Sky Air • RZQSG-L3/9V1
3
12
• Outdoor Unit • RZQSG-L3/9V1
12 Installation12 - 1 Installation Method
• Split - Sky Air • RZQSG-L3/9V1 41
• Outdoor Unit • RZQSG-L3/9V1
13
42
13 Operation range13 - 1 Operation Range
• Split - Sky Air • RZQSG-L3/9V1
Daikin Europe N.V. participates in the Eu-rovent Certification programme for LiquidChilling Packages (LCP), Air handling units(AHU), Fan coil units (FCU) and variable re-frigerant flow systems (VRF) Check ongo-ing validity of certificate online:www.eurovent-certification.com or using:www.certiflash.com
EE
DE
N1
5-1
00A
0
5/1
5 C
opyr
igh
t Da
ikin
T
he p
rese
nt p
ub
lica
tion
su
per
sede
s E
ED
EN
14-
100A
The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.has compiled the content of this leaflet to the best of its knowledge. Noexpress or implied warranty is given for the completeness, accuracy, re-liability or fitness for particular purpose of its content and the productsand services presented therein. Specifications are subject to changewithout prior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or re-lated to the use and/or interpretation of this leaflet. All content is copy-righted by Daikin Europe N.V.
BARCODE Daikin products are distributed by:
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende