B.A.B. Location
72
565
HOLMES AVE. NW
SPAR
KMAN
DR.
HOLMES AVE. NW
Sheet # Sheet Name Issued Rev # Rev Date Rev Description
1. GENERALTS.1 TITLE SHEET 02/25/2020TS.2 GENERAL INFORMAITON 02/25/20202. CODE COMPLIANCECC1.0 CODE COMPLIANCE PLANS 02/25/20203. ARCHITECTUREA0.1 DEMOLITION PLAN - FIRST FLOOR 02/25/2020A0.2 DEMOLITION PLAN - SECOND FLOOR 02/25/2020A1.0 GENERAL INFORMATION FIRST AND SECOND FLOOR PLANS 02/25/2020A1.1 FIRST FLOOR - OVERALL RENOVATION PLAN 02/25/2020A1.2 SECOND FLOOR - OVERALL RENOVATION PLAN 02/25/2020A1.2a CYBERSECURITY LAB - ENLARGED SECOND FLOOR PLAN 02/25/2020A6.0 INTERIOR ELEVATIONS & DETAILS 02/25/2020A7.0 PARTIAL SECOND FLOOR FINISH PLAN, INTERIOR FINISH LEGEND AND SCHEDULE 02/25/2020A7.1 CYBERSECURITY LAB - SECOND FLOOR FURNITURE PLAN 02/25/2020A8.0 DOOR SCHEDULE, DOOR AND FRAME DETAILS, AND INTERIOR DETAILS 02/25/2020A9.1 FIRST FLOOR - REFLECTED CEILING PLAN 02/25/2020A9.2 SECOND FLOOR - REFLECTED CEILING PLAN 02/25/20204. MECHANICAL, PLUMBING, FIRE PROTECTIONFP1.0 FIRE PROTECTION FLOOR PLAN 02/25/2020M1.0 MECHANICAL FLOOR PLAN 02/25/2020M2.0 MECHANICAL FLOOR PLAN 02/25/2020M3.0 MECHANICAL SCHEDULES 02/25/2020P1.0 PLUMBING FLOOR PLAN - DEMOLITION 02/25/2020P2.0 PLUMBING FLOOR PLAN - NEW CONSTRUCTION 02/25/20205. ELECTRICALE0.1 ELECTRICAL LEGEND, SYMBOLS, & NOTES 02/25/2020E0.2 ELECTRICAL SCHEDULES & LIGHTING RISER DIAGRAM 02/25/2020E1.1 OVERALL SECOND FLOOR DEMOLITION PLAN - ELECTRICAL 02/25/2020E2.1 OVERALL SECOND FLOOR PLAN - LIGHTING 02/25/2020E2.2 PARTIAL SECOND FLOOR PLAN - LIGHTING 02/25/2020E3.2 PARTIAL SECOND FLOOR PLAN - POWER 02/25/2020E4.2 PARTIAL SECOND FLOOR PLAN - TECHNOLOGY 02/25/2020
INDEX OF DRAWINGS
MECHANICAL, PLUMBING & FIRE PROTECTION
ELECTRICAL
Mechanical Design Solutions, Inc.
100 Church St. Suite 650Huntsville, Alabama 35801
Phone: 256-534-5150www.mdseng.com
SSOE Group
303 Williams Avenue SWSuite 1211
Huntsville, AL 35801Phone: (256) 534-2353
www.ssoe.com
DESIGN TEAMLOCATION MAP
ARCHITECTFUQUA & PARTNERS
ARCHITECTS
100 Church Street, Suite 700Huntsville, AL 35801
(256) 534 3516Contact: Rodney Steger
email: [email protected]
301 SPARKMAN DRIVE, HUNTSVILLE, AL 35899
UAH - BAB Cyber Lab / Interior Renovations
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:17:
45 A
M
TS.1
TITL
E SH
EET
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LWF
02-25-2020
FPA #07519
RKS
100 % CDs
21
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
REVISIONS
FIRE EXTINGUISHER
3'-0"MIN
16"-18"
WATER
FIRE EXTINGUISHER CABINET
TELEPHONE HOUSING WHEELCHAIR ACCESSIBLE
(N.I.C.)
48" M
AX
TO
HIG
HES
TO
PERA
BLE
WALL PHONE (N.I.C.)33
" - 3
6"
WATER
AFF
SEAT
17" -
19"
42" MIN
54" MIN
MAX1'-0"
39" -
41"
MIN
1'-6"
39" - 41" 2'-0"
URINAL
URINAL SCREEN (WHERE OCCURS)
1'-1 1/2"MIN
1'-0"MINMIN2'-0"
59" MIN
5'-0"MIN
MIN1'-3"
LAVATORY OR VANITY SINK
OFFSET WASTE
ACCESSIBLE SINK BOWL 6 1/2" DEEP
COUNTER WHERE OCCURS
INSULATE EXPOSED PIPING
ADA SHOWER
CONTROL WALL(CONTROLS)
CONTROLAREA
ENTRANCE SIDE
THERMOSTAT
48" M
AX
48" M
AX
SWITCH/ CARD READER
ROOM SIGN
4'-0"
MIN
5'-0"
MAX
F.F.L.
3'-6"
RECESSED PAPER TOWELDISPENSER &
4'-6"
MAX
1'-5" M
AX2'-
10"
2'-3"
TO H
IGH
EST
OPE
RABL
E D
EVIC
E
48" M
AX
TO
HIG
HES
TO
PERA
BLE
48" M
AX
TO
HIG
HES
TO
PERA
BLE
TO
HIG
HES
TO
PERA
BLE
TO H
IGH
EST
OPE
RABL
ED
EVIC
E
48" M
AX T
O
HIG
HES
TO
PERA
BLE
DEV
ICE
FRO
M F
FL O
R G
ROU
ND
SUR
FAC
E TO
BAS
ELIN
E O
F H
IGH
EST
TAC
TILE
C
HAR
ACTE
R
FRO
M F
FL O
R G
ROUN
D S
URF
ACE
TO B
ASEL
INE
OF
LOW
EST
TAC
TILE
C
HAR
ACTE
R
SEAT WALL
17"-1
9"
CONTROL WALL (GRAB BARS)
FOLDINGADA
ENTRANCE SIDE
GRAB BARS
TOP
OF
GRA
S PIN
G S
URFA
CE2'-
10"M
IN T
O 3
6" M
AX T
O
TWO-WALL TUB/SHOWER GRAB BAR
TOILET SEATCOVER
DISPENSER
TO
HIG
HES
TO
PERA
BLE
9" M
IN
PARTITIO
33" -
36"
18" M
IN
CO
NTR
OL
44" M
AXFL
USH
4'-0"
SEMI RECESSED PAPER TOWEL RECEPTACLE
TO
HIG
HES
TO
PERA
BLE
48" M
AX
48" M
AX
6"MAX TOE9"M
IN.
KNEE8" MINM
IN2'-
5"
1'-5" MIN DEPTH
MAX
2'-3" MAX
2'-10
"
LAVATORY - WALL (TYPICAL H.C.)
INSULATE BOOT ON EXPOSED DRAIN PIPE
INTERIOR SIGNAGE: LATCH
SIDE OR NEAREST
FIRE ALARM WITH STROBE
TO B
/ DEV
ICE
6'-8"
MIN
1'-6"MIN
9" MIN
EQ EQCENTERED ON TACTILE CHARACTERS
T.O
. PUL
L DO
WN
42 -
48" T
O
MIN
1'-6"
30" C
NTR
TP.
3'-2"
34" C
NTR
TP.
3'-6"U.N.
O.
4'-6"
MAX
ELECTRICAL DEVICES: ROTATEELECTRICAL COVER PLATES
HORIZONTAL IF COUNTERTOP IS ABOVE 42" HIGH
2'-6"
2'-10
"
SANITARYNAPKIN
DISPOSAL
RECESSED
SANITARYNAPKIN
SANITARYNAPKIN
DISPENSE
WALL MOUNTED SOAP DISPENSER
TO
HIG
HES
TO
PERA
BLE
TO
HIG
HES
TO
PERA
BLE
PAPER TOWEL DISPENSER
TO
HIG
HES
TO
PERA
BLE
18" M
IN
TOILET PAPER DISPENSER
RECESSED TOILET PAPER DISPENSER/HOLDER
ZONE
18" M
IN
TOILET PAPER HOLDER
MIN
1'-6" 4'-
0" M
AX
3'-6" MAX
3'-0" MAX
12" M
IN (I
F M
OU
NTE
D AB
OVE
GRA
B BA
R)
12" M
IN (I
F M
OU
NTE
D AB
OVE
GRA
B BA
R)
BEL
OW
GRA
B BA
R)
1-1/
2" M
IN B
ELO
W B
AR(IF
MO
UNTE
D
BELO
W G
RAB
BAR)
1-1/
2" M
IN B
ELO
W B
AR(IF
MO
UNTE
D
BAR
BAR
ABO
VE G
RAB
BAR)
48" M
AX (I
F M
OUN
TED
ABO
VE G
RAB
BAR)
48" M
AX (I
F M
OUN
TED
48" M
AX
48" M
AX
48" M
AX
E.W.C. (WC ACCESSIBLE)
TO S
POUT
3'-0"
MAX
E.W.C. (STANDING PERSON)
TO S
POUT
38" -
43"
4" MAX
3"-6
"
33"-3
6"
1'-3"
ENTRANCE SIDE
BACK WALL
1'-6"
17"-1
9"
HEAD END WALL
33" -
3'-0"
CONTROL END WALL
33" -
3'-0"
ADA TUB
8"-1
0"
BACK WALL(BARS)
33" -
36"
BACK WALL(SEAT)
REMOVABLE TUB SEAT, 15-16" WIDE
17-1
'-7"
24" MIN
18" M
IN
3" -
6"
1'-0"MIN
3'-6"
FLIP DOWNBABY CHANGE UNIT
TOWEL BAR
SHOWERCURTAIN ROD
6'-8"
TO H
IGH
EST
OPE
RABL
ED
EVIC
E
ROBE/ COATHOOK
4'-0"
MAX
MIRRO
3'-4"
MAX
TO B
OTT
OM
OF
REFL
ECTI
VE S
URFA
CE
40" M
IN -
48"
MAX
COAT RACK
5'-6"
BROOM/MOPHOLDER
48" M
AX
F.F.L.
F.F.L.
F.F.L.
F.F.L.
1. TYPICAL HEIGHTS: MOUNTING HEIGHTS INDICATED HEREIN ARE TYPICAL MOUNTING HEIGHTS FOR DEVICE INDICATED. HOWEVER, MOUNTING HEIGHTS FOR PRODUCTS MAY VARY BY MANUFACTURER, AND THEREFORE THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT WHERE A DISCREPANCY EXISTS BETWEEN THE INDICATED MOUNTING HEIGHT AND THE MANUFACTURER RECOMMENDED MOUNTING HEIGHT, PRIOR TO INSTALLATION OF THE DEVICE.
2. THE GENERAL CONTRACTOR SHALL REFER TO FLOOR PLANS FOR LOCATIONS OF DEVICES SHOWN HEREIN. 3. ADA DEVICES: ALL DEVICES AND FIXTURES NOTED AS “ADA” OR “ACCESSIBLE” SHALL BE INSTALLED IN
STRICT ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT AND APPLICABLE BUILDING CODES.
4. ELECTRICAL DEVICES: SEE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR REQUIRED MOUNTING HEIGHT OF ELECTRICAL DEVICES AND FIXTURES. WHERE CONFLICTS EXIST BETWEEN MOUNTING HEIGHTS INDICATED HEREIN AND THE REQUIREMENTS OF THE ELECTRICAL ENGINEER, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT PRIOR TO ROUGH-IN.
5. MECHANICAL/PLUMBING DEVICES: SEE MECHANICAL AND PLUMBING DRAWINGS AND SPECIFICATIONS FOR REQUIRED MOUNTING HEIGHT OF MECHANICAL AND PLUMBING DEVICES AND FIXTURES. WHERE CONFLICTS EXIST BETWEEN MOUNTING HEIGHTS INDICATED HEREIN AND THE REQUIREMENTS OF THE MECHANICAL ENGINEER, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT PRIOR TO ROUGH-IN.
6. INSTALL ADA / ANSI COMPLIANT UNDER LAVATORY GUARDS ON ALL EXPOSED SINK PIPING.
UNOBSTRUCTED SIDE REACH
WALL MTD.
OBSTRUCTED HIGH SIDE REACH
WALL MTD. DEVICE
FIXED OBJECT
WALL MTD. DEVICE
FIXED OBJECT
TO H
IGH
EST
OPE
RABL
E DE
VIC
E
TO H
IGH
EST
OPE
RABL
E D
EVIC
E
TO H
IGH
EST
OPE
RABL
E
10" MAX
34" M
AX
34" M
AX
3'-10
"MAX
4'-0"
MAX
48" M
AX
MIN
1'-3"
10"MAX MAX>10" - 24"
UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH
TO H
IGH
EST
OPE
RABL
E DE
VIC
EWALL MTD. DEVICE WALL MTD. DEVICE
COUNTER TOP
WALL MTD. DEVICE
F.F.L.
TO H
IGH
EST
OPE
RABL
E
COUNTER TOP
MIN
1'-3"
4'-0"
MAX
SEE
ELEV
.
4'-0"
MAX
SEE
ELEV
. HIG
HES
T O
PERA
BLE
DEVI
CE3'-
8"M
AX T
O
MAX>20" - 25"
MAX1'-8"
F.F.L.
AC acre ACC accessibleACI American Concrete Institute ACT acoustical ceiling tile ADD addendum AFF above finished floor ALT alternate ALUM aluminum APPROX approximate ARCH architect (ural)ADJ adjacent
B&B balled and burlapped B/B back to back BC base of curb BD board BLDG buildingBLKG blocking BM benchmark BOT bottom BRG bearingBSMT basementBUR built-up roof BOW bottom of wallB/W between
C channelCAB cabinet CAL caliper CB catch basin C/C center to center CD core deck CF cubic footCI cast iron CIP cast iron pipe CJ construction or control joint CLG ceiling CLO closet CLR clear (ance) CMP corrugated metal pipe CMU concrete masonry unit CO clean out COL column CONC concrete CONN connection CONST construction CONT continuous or continue COORD coordinateCPT carpet (ed)CS countersink CSMU calcium silicate masonry unit
CT ceramic tile CW curtain wallCY cubic yard
D dryer DBL double DEM demolish or demolition DET detail DH double hung DIA diameter DIAG diagonal DIM dimension DIP ductile iron pipe DL dead loadDS downspout DWG drawing DF drinking fountain
EA each EF each face EIFS exterior insulation finish system EJ expansion joint ELEV elevation/elevator ELEC electric (al)ENGR engineer EOP edge of pavement
FRT fire retardant treatedFT foot/feet FTG footing
GA gauge GALV galvanizedGHM galvanized hollow metalGI galvanized iron GWB gypsum wall board GYP gypsum
H heightHC handicapHM hollow metal HORIZ horizontal HP high point/horse powerHSS hollow structural steelHVAC heating/ventilating/air conditioning HW hardware
ID inside diameter IE invert elevation IJ isolation joint IN inch/inches INSUL insulation
JAN janitor's closet JG joist girder JT joint
K thousand KIP 1000 # KJ key joint KSI 1000 # per sq in
LAM laminate (d) LF linear foot L length, angleLAB laboratory LAV lavatory LH left hand LL live load LLH long leg horizontalLLV long leg vertical LP low point LT GA light gauge LT light
EOS edge of slab EQ equal EW each way EWC electric water cooler EXH exhaust EXIST existing EXP exposedEXPN expansion EXT exterior
FBO furnished by others FD floor drain FEC fire extinguisher and cabinet FFE finish floor elevationFFL finish floor levelFHC fire hose and cabinetF/F face to faceFL floor FLG flange FND foundation FO face of FOB face of brick FOC face of concrete FOF face of finish FOM face of masonry FOS face of studFR frame (ed), (ing)
MATL material MAX maximum MC miscellaneous channelMECH mechanical MEZZ mezzanine MANUF manufacture (er) MH manhole MIN minimumMO masonry openingMULL mullion
NIC not in contract NO number NOM nominalNTS not to scale
O/H overheadOC on center (s) OCC occupant (s)OD outside diameterOH opposite hand OPG opening OPP opposite
PJ precast jointPL property line, plate
REQ'D required RET retaining REV revision (s), revisedRH right hand RJ recessed jointRM roomRO rough opening ROW right of way RTU roof top unit
SC sealed concrete SCHED scheduledSD storm drain SECT sectionSF storefrontSIM similar SPEC specification (s) SQ square SS solid surface SST stainless steel STD standardSTL steelSTOR storage STRUCT structuralSY square yard
PLAM plastic laminatePNT paint (ed)PREFAB prefabricatedPREFIN prefinishedPREMANUF premanufacturedPSF pounds per square foot PSI pounds per square inch PT point / pressure treated/
point of tangencyPVC polyvinyl chloride PVMT pavement PWD plywood
QT quarry tile
RA return air RAD radius RB rubber base RCP reflected ceiling plan RD roof drain REBAR reinforcement bar REF refrigerator/ reference REINF reinforce (d), (ing)
VB vinyl base VCT vinyl composition tile VERT vertical VWC vinyl wall covering
W washer/width/wide flange WB wood base WC water closet WD wood WH water heater WIN window WP work point,
waterproofingWT weight W/W wall to wall WWF welded wire fabric W/ with W/O without
TELE telephoneTERM terminationT&G tongue and groove TH thick (ness)THK thick (ness)TO top ofTOC top of curbTOF top of footingTOJ top of joistTOS top of slab/top of steelTOW top of wallTYP typical TZ terrazzo
UNO unless noted otherwise
A0.0
11 1
1
000
3
0 REFLECTED CEILING PLANA101 1/8" = 1'-0"View Description
S1
1A101
SIM
ROOM REFERENCE SYMBOL:
COLUMN LINES: 2 - CONSECUTIVE NUMBERS (123) ARE USING FOR COLUMN LINES RUNNING NORTH & SOUTH A - CONSECUTIVE LETTERS (ABC) ARE USED FOR COLUMN LINES RUNNING EAST & WEST
NOTE: IF A COLUMN LINE IS ADDED, "SUB" NUMBERS/LETTERS ARE USED
00.00
DATUM SYMBOL (ELEVATION MARK)00.00 - ELEVATION (FT)
REVISION SYMBOLUSED TO INDICATE SCOPE OF CURRENT REVISION
DOOR SYMBOL:-DOOR NUMBER 000-DOOR TYPE ASEE DOOR SCHEDULE & FLOOR PLANS
WINDOW SYMBOL:-WINDOW TYPE 00SEE EXTERIOR ELEVATIONS & WINDOW SCHEDULE
WALL SYMBOL:-WALL TYPE 3 SEE PARTITION LEGEND
BUILDING SECTION SYMBOL:SECTION 0 ON SHEET A0.0
WALL SECTION SYMBOL:SECTION 0 ON SHEET A0.0
ENLARGED PLAN / DETAIL SYMBOL:DETAIL 0 ON SHEET A0.0
ELEVATION SYMBOL:ELEVATION 1 ON SHEET A0.0
SPECIALTY EQUIPMENT TAG:-SPECIALTY EQUIPMENT TYPE S1SEE SPECIALTY EQUIPMENT SCHEDULE
PLAN KEYNOTE TAG- NOTE NUMBER 3SEE PLAN KEYNOTE SCHEDULE
CASEWORK TAGCASEWORK HAS BEEN DEVELOPED USING THE ARCHITECTURAL WOODWORK STANDARDS CASEWORK DESIGN SERIES DESIGNATIONS
-- ROOM NAME 1--: FLOOR NUMBER -- 01: SPACE NUMBER150 SF: NET SQUARE FOOTAGE
Room name101
150 SF
0
0
LEVEL
1
0A0.0
SIM
NORTH ARROW
0A0.0
SIM
500M30 24
36modification
3
FFENOT IN CONTRACT
00
MOUNTING HEIGHT LEGEND
ACRONYMS & ABBREVIATIONS
DRAWING SYMBOLS
TYPICAL ADA REACH RANGE
MOUNTING HEIGHT NOTES
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:17:
51 A
M
TS.2
GEN
ERAL
INFO
RMAI
TON
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
AWF/ LF
02-25-2020
FPA #07519
RKS
100 % CDs
22
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
REVISIONS
UP
UP
UP
- D et ail
UP
145'
65'
2 HR RATED PARTITION
FIRE EXTINGUISHER CABINET
MAXIMUM TRAVEL DISTANCE TO EXIT
COMMON PATH OF TRAVEL
CLEAR EXIT WIDTH IN INCHES
EXIT SIGN
FEC
1 HR RATED PARTITION
34170 DOOR CLEAR WIDTH & EXIT CAPACITY
NOT IN SCOPE
ADJACENT EXISTING BUILDING(UAH I2C: BC#2016472)
EXIT
EXIT
EXIT
EXIT
EXIT
EXIT
FEC
EXIT
EXIT
EXIT
EXISTINGSTUDY
RESOURCE
EXISTINGTRADE LAB
CONFERENCEPBX
MAIL RM
ELECT.
EXISTINGMECHANICAL
EXISTINGTEAM
EXISTINGTEAM
EXISTINGTEAM
EXISTINGTEAM
EXISTINGTEAM
EXISTINGCASE
ROOM #2
EXISTINGCASE
ROOM #1EXISTINGSTAIR
ADMIN.
EXISTINGRECORD
EXISTINGRECEPTION
B.S.CONTROL
EXIST.CORRIDOR
BEHAV.SCIENCE
STUDYALCOVE
EXIST.CORRIDOR
EXISTINGATRIUMLOBBY
EXISTINGCASE
ROOM #3
EXISTINGCASE
ROOM #4
EXISTINGCASE
ROOM #5
EXISTINGMECHANICAL
MEN
EXIST. JAN.
EXISTINGAUDITORIUM
EXISTINGCORRIDOR
FEC
FEC
EXISTING RATED STAIR SHAFT EXTENDS TO GRADE LEVEL EXIT
EXISTING RATED STAIR SHAFT EXTENDS TO GRADE LEVEL EXIT
EXISTING BUILDING:28,000 S.F. PER FLOORTYPE 2A, SPRINKLERED
EXISTING ELEVATOR
EXISTING ELEVATOR
5'-7 1/4"
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGCORRIDOR
EXISTINGCORRIDOR
EXISTINGSTAIRS
EXISTINGOFFICEEXISTING
OFFICEEXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXIST.WORKROOM
EXIST.CONF.
EXIST.CONF.
EXISTINGCORRIDOR
EXIST.ELEV.
AIRLOCK
EXIST. CORRIDOR
EXIT
EXIT
EXIT
OPEN TO BELOW
DOWN
DOWN
UP
ELEVATOR
DOWN
UP
DOWN
DOWN
FEC
WOMEN
PBX
MEN
EXIST.CLASSROOM
EXIST.CORRIDOR
COMPUTERCLASSROOM
EXIST.CORRIDOR
EXISTING RATED STAIR SHAFT EXTENDS TO GRADE LEVEL EXIT
EXISTING RATED STAIR SHAFT EXTENDS TO GRADE LEVEL EXIT
EXISTING UAH I2C BUILDING
EXISTING BUILDING:28,000 S.F. PER FLOORTYPE 2A, SPRINKLERED
EXISTING ELEVATOR
EXISTING ELEVATOR
SHADED AREA IS SCOPE OF WORK AREA
EXIT
EXIST.CLASSROOM
EXIST.CLASSROOM
CLASSROOM
EX.SERVERROOM
EXISTINGPORCH
EXISTING MONUMENTAL STAIR
TRAVEL DISTANCE = 49'
EXIST.CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
EXISTINGMECHANICAL
RECEPTION
CONFERENCEROOM
SECRETARY
TOIL.
OFFICE
OFFICE
OFFICE
OFFICE
CORRIDOR
EXISTINGMECHANICAL
OFFICE
EXIST.BALCONY
EXIST.BALCONY
EXIT
CYBERSECURITYLAB
LABSUPPORT
CYBERLOUNGE
JAN CLOSET
CLOSET
EXIST. CORRIDOR
UTILIY
EXIST. LAB
EXIST. LAB
FEC
EXISTING RATED STAIR SHAFT EXTENDS TO GRADE LEVEL EXIT
EXISTING RATED STAIR SHAFT EXTENDS TO GRADE LEVEL EXIT
EXISTING BUILDING:28,000 S.F. PER FLOORTYPE 2A, SPRINKLERED
EXISTING ELEVATOR
EXISTING ELEVATOR
EXISTING MONUMENTAL STAIR
FACULTY /STAFF
CORR.
MEN
OFFICE(TYP.)
2015 International Building Code
2015 International Plumbing Code
2015 International Mechanical Code
2015 International Fuel Gas Code
2015 International Fire Code
2014 National Electric Code
ANSI/ASHRAE/IESNA Standard 90.1-2013 Energy Standard for
Buildings Except Low-Rise Residential
2010 Americans with Disability Act Accessibility Standards
2003 National Fire Code (NFPA)
APPLICABLE CODES & REGULATIONS
2013 National Fire Alarm and Signaling Code (NFPA 72)
2015 International Existing Building Code
GENERAL INFORMATION
EXISTING BUILDINGS - CHAPTER 3 - COMPLIANCE METHODS
EXISTING BUILDINGS - CHAPTER 5 - CLASSIFICATION OF WORK
CONSTRUCTION TYPE AND SPRINKLER INFORMATION
PRIMARY OCCUPANCY CLASSIFICATION(S)
OCCUPANCY LOAD
MEANS OF EGRESS
PROJECT SCOPE CONSISTS OF INTERIOR RENOVATIONS
WORK AREA COMPLIANCE METHOD
FIRST FLOOR : LEVEL 1 ALTERATIONS - REMOVAL AND REPLACEMENT OF EXISTING FINISHES ONLYSECOND FLOOR : LEVEL 2 ALTERATIONS - RECONFIGURE AN EXISTING CLASSROOM AREA. REMOVAL AND REPLACEMENT OF EXISTING FINISHES
EXISTING TYPE 2A CONSTRUCTION, FULLY SPRINKLERED, IS BEING MAINTAINED.
EXISTING BUILDING OCCUPANCY WILL NOT CHANGE. CURRENT OCCUPANCIES INCLUDE:BUSINESS GROUP BASSEMBLY GROUP A-3
EXISTING OCCUPANCY LOAD IS BEING MAINTAINED.
NUMBER OF EXITS IS BEING MAINTAINED.EGRESS WIDTH AND PATH OF TRAVEL IS BEING MAINTAINED.ACCESSIBILITY MEANS OF EGRESS IS BEING MAINTAINED.
PLUMBING SYSTEMS NUMBER OF EXISTING FIXTURES COMPLIES WITH LEVEL 1 AND LEVEL 2 ALTERATIONS REQUIREMENTS.
LIFE SAFETY PLAN LEGEND
CC1.0 1/16" = 1'-0"
1 LIFE SAFETY PLAN - FIRST FLOOR
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:17:
37 A
M
CC1.0
CO
DE
CO
MPL
IAN
CE
PLAN
S
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
11
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
CC1.0 1/16" = 1'-0"
2 LIFE SAFETY PLAN - SECOND FLOOR
CC1.0 1/16" = 1'-0"
3 LIFE SAFETY PLAN - THIRD FLOOR
REVISIONS
- De ta il
EXISTING CASEROOM #1
161
EXISTING TEAM117
EXISTING TEAM116
EXISTING TEAM118
EXISTING TEAM119
EXISTING CASEROOM #3
120
EXISTINGMECHANICAL
158
EXISTING TEAM159
EXISTING CASEROOM #2
160EXISTING STAIR
101EXISTING RECORD102
EXISTINGRECEPTION
110
STUDY ALCOVE114
EXIST. CORRIDOR115
EXIST. CORRIDOR115
EXISTING CORRIDOR146
EXISTING STUDYRESOURCE
150
EXISTING TRADE LAB147
WOMEN151
MEN144
EXISTING ATRIUMLOBBY
121
EXISTING CORRIDOR125
EXISTING CORRIDOR125
EXISTINGAUDITORIUM
26
EXISTINGMECHANICAL
142EXIST. JAN.145
EXISTING CASEROOM #4
123
EXISTING CASEROOM #5
124
EXIST. ELEV.143
BEHAV. SCIENCE113
B.S. CONTROL112
EXISTING OFFICE207EXISTING OFFICE
218
EXISTING OFFICE221
EXISTING OFFICE226
EXISTING OFFICE233
EXIST. WORKROOM126
EXISTING OFFICE128
EXISTING OFFICE127
EXIST. CONF.136
EXIST. CONF.135
EXISTING CORRIDOR137
EXISTING OFFICE134
EXISTING OFFICE129
EXISTING OFFICE130
EXISTING OFFICE131
EXISTING OFFICE132
EXISTING OFFICE133
EXISTING STAIRS256
EXISTING CORRIDOR137
AIRLOCK146A
2222
22
22 22
25
25
24
24
*ONLY AS REQUIRED FOR WORKABOVE
*ONLY AS REQUIRED FOR WORKABOVE
A. PRE-DEMOLITION MEETING: PRIOR TO THE ACTUAL START OF DEMOLITION WORK, THE CONTRACTOR SHALL SCHEDULE A PRE-DEMOLITION MEETING. THIS MEETING SHALL BE ATTENDED BY THE ARCHITECT, CONTRACTOR, SUPERINTENDENT, DEMOLITION FORMAN, AND OWNER. THE MEETING SHALL BE HELD AT THE CONSTRUCTION SITE. THE PURPOSE OF THE MEETING IS TO REVIEW THE SCOPE OF DEMOLITIONAND ALL ITEMS TO BE SALVAGED DURING DEMOLITON. THE CONTRACTOR SHALL PROVIDE A SET OF PLANS FOR THE MEETING. THE PLANS SHALL BE USED TO REVIEW AND MARK SPECIFIC ITEMS OF QUESTION. ALL ITEMS SHALL BE RESOLVED AND PART OF THE RECORD MINUTES TO BE DISTRIBUTED TO ALL PARTIES FOR RECORD. NO DEMOLITION SHALL OCCUR UNTIL THIS MEETING HAS BEEN CONDUCTED.
B. DEMOLITION DRAWINGS: DEMOLITION DRAWINGS ILLUSTRATE THE GENERAL SCOPE OF DEMOLITION WORK TO BE PERFORMED AND ARE NOT INTENDED TO BE COMPREHENSIVE OR ALL-INCLUSIVE. THE CONTRACTOR SHALL PERFORM THE DEMOLTION WORK INCLUDED IN THE DEMOLITION PLANS AND ITS ASSOCIATED CONSTRUCTION, ALONG WITH ANY AND ALL DEMOLITION REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE NEW CONSTRUCTION WORK TO BE PERFORMED, INCLUDING THAT REQUIRED OF ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND SIMILAR APPLICABLE SUB-CONTRACTOR WORK.
C. TEMPORARY BRACING: PRIOR TO REMOVAL OF EXISTING STRUCTURAL ELEMENTS, THE CONTRACTOR SHALL TEMPORARILY SHORE AND/OR BRACE EXISTING CONSTRUCTION TO REMAIN AS REQUIRED TO SUPPORT EXISTING LOADS AND/OR LOADS IMPOSED DURING CONSTRUCTION.
D. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, CONSTRUCTION, MATERIALS, METHODS OF CONSTRUCTION, ELEVATIONS, ETC. PRIOR TO BIDDING, CONSTRUSTION, AND INSTALLATION. NOTIFY ARCHITECT OF ANY CONDITIONS WHICH MAY IMPACT THE BID, INCLUDING BUT NOT LIMITED TO CONCEALED CONDITIONS AFFECTING THE WORK AND ANY DISCREPANCIES WITHIN DOCUMENTS OR ENCOUNTERED DURING CONSTRUCTION PRIOR TO PROCEEDING WITH WORK.
E. ALL WORK SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES TO AVOID INTERFERENCES AND CONFLICTS. REFER TO THE DRAWINGS OF THE RESPECTIVE SYSTEMS PRIOR TO SUBMISSION OF BIDS FOR ADDITIONAL WORK WHICH MAY BE REQUIRED AS PART OF THEIR WORK. NO ALLOWANCES WILL BE MADE FOR THE LACK OF COORDINATION BETWEEN DISCIPLINES OR SYSTEMS AND EQUIPMENT.
F. THE CONTRACTOR SHALL TAKE EXTREME CAUTION TO FULLY INVESTIGATE EXISTING FINISHES, CONSTRUCTION, MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS PRIOR TO DEMOLITION TO ASSURE CRITICAL SERVICES ARE NOT INTERRUPTED.
G. IT IS THE CONTRACTORS RESPONSIBILTY TO BARRICADE OFF AREA OF WORK AND PROVIDE PROTECTED ENTRANCES AND EXITS TO AND FROM THE BUILDING. DO NOT BLOCK EXITS.
H. PROJECT PLANS HAVE BEEN DEVELOPED FROM DRAWINGS PREVIOUSLY PREPARDED BY OTHERS. ACTUAL CONDITIONS MAY VARY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS RELATED TO EXISTING CONSTRUCTION AND MAKE MINOR ADJUSTMENTS AS REQUIRED. CONTRACTOR SHALL REPORT ANY DIFFERENCES TO THE ARCHITECT PRIOR TO BIDDING.
I. IT IS THE CONTRACTORS SOLE RESPONSIBILITY DURING DEMOLITION TO PROVIDE PROTECTION FOR ALL EXISTING CONSTRUCTION TO REMAIN. CONTRACTOR TO PATCH, REPAIR, AND REPLACE ANY AND ALL EXISTING CONSTRUCTION DAMAGED BY THE DEMOLITION, INCLUDING BUT NOT LIMITED TO: EXISTING STRUCTURE, FINISHES, CEILINGS. THE CONTRACTOR SHALL ALSO PROVIDE PROTECTIVE BARRIERS FROM DUST AND WEATHER DURING DEMOLITION SO AS NOT TO DAMAGE EXISTING CONSTRUCTION INDICATED TO REMAIN.
J. THE CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL DEMOLITION REQUIRED FOR THE COMPLETION OF THE WORKS AS DESCRIBED IN THE CONTRACT DOCUMENTS. THESE ITEMS INCLUDE BUT ARE NOT LIMITED TO: PIPING, WIRING, ETC. ANY CLARIFICATION REQUIRED SHALL BE OBTAINED FROM THE ARCHITECT, IN WRITING.
K. IT IS THE INTENT THAT WHERE NEW WORK IS INDICATED, THAT SOME EXISTING FINISHES, MATERIALS, ETC. SHALL BE REMOVED AS NECESSARY AND PRACTICAL TO INSTALL THE NEW WORK. ALL ADJACENT WALLS, CEILINGS, FLOORS, FINISHES, ETC. SHALL BE PREPARED AS REQUIRED TO RECEIVE NEW WORK.
L. EXISTING VCT TO REMAIN, UNLESS NOTED OTHERWISE.M. WHEN FLOORING IS TO BE REMOVED THE CONTRACTOR SHALL PROVIDE IN THE BASE BID ANY AND ALL COSTS ASSOCIATED WITH THE
REMOVAL OF THE EXISTING FLOORING SYSTEMS, DAMAGED SUBSTRATES, AND ANY OTHER ASSOCIATED CONSTRUCTION. THE BASE BID SHALL ALSO INCLUDE THE PATCHING, REPAIR AND LEVELING OF ANY EXISTING SUBSTRATE TO RECIEVE NEW FLOORING SYSTEMS.
N. CODE COMPLIANCE: PERFORM ALL WORK IN STRICT ACCORDANCE WITH APPLICABLE LAWS, CODES, AND ORDINANCES.O. SECURE NECESSARY PERMITS AND APPROVALS FOR WORK IN AND ADJACENT TO CITY RIGHT-OF-WAYS. P. ALL DUCTWORK, PIPING AND CONDUIT SCHEDULED FOR SELECTIVE DEMOLITION SHOULD INCLUDE COMPLETE REMOVAL INCLUDING ALL
HANGERS, SUPPORTS, TECH.Q. REMOVE ALL EXISTING BASE TRIM, WAINSCOT TRIM, FLOORING, WALL COVERING, AND WALL ACCESSORIES WITHIN THE SCOPE OF WORK
AREA.
DEMOLITION/CONSTRUCTION NOTES
EXISTING WALLS TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
DEMOLITION KEY NOTES
WALLS TO BE MODIFIED
EXTENT OF CEILING RENOVATION
BEYOND EXTENT OF RENOVATION
EXISTING FIXTURES TO BE DEMOLISHED
DEMOLITION PLAN LEGEND
2
DEMOLITION KEY NOTES#
AIR RETURN (V.I.F.)
AIR SUPPLY (V.I.F.)
1. REMOVE AND REPLACE EXISTING CEILING. SEE RCP DEMOLITION PLAN FOR ADDITIONAL INFORMATION2. EXISTING EXIT LIGHTS, FIRE PULL, PUSH TO EXIT BOXES, AND THERMOSTAT TO BE REMOVED. RELOCATE ANY DEVICES AS INDICATED ON
ELECTRICAL ENGINEERING DRAWINGS3. EXISTING STEEL COLUMN AND RAIN WATER LEADER TO REMAIN4. EXISTING MARKER BOARD, WALL CLOCK, PROJECTION SCREEN, AND ACCESSORIES TO BE REMOVED AND TURNED OVER TO OWNER.5. EXISTING HVAC UNIT TO REMAIN6. EXISTING ELECTRICAL PANELS TO REMAIN7. EXISTING WATER COOLER TO BE REMOVED AND LINES CAPPED OR REROUTED TO NEW WATER COOLER LOCATION, PER ENGINEERING
DRAWINGS.8. REMOVE EXISTING CASEWORK AND TURN OVER TO OWNER9. DEMOLISH EXISTING WOOD SHELVING10. REMOVE EXISTING WALL-MOUNTED ELECTRICAL RACEWAY11. EXISTING THERMOSTAT. RELOCATE PER ENGINEERING DRAWINGS12. REMOVE EXISTING TELEVISION WALL MOUNT AND TURN OVER TO OWNER13. EXISTING CEILING GRID TO REMAIN. CEILING TILES TO BE REPLACED. 14. EXISTING LIGHTING TO BE RE-USED IF FIXTURES ARE LED, IF NOT REPLACE WITH LED FIXTURES AND INSTALL PER ELECTRICAL
ENGINEERING DRAWINGS.15. SALVAGE EXISTING DOORS FOR POSSIBLE RE-USE. (IF DOORS ARE TO BE RE-USED TOUCH UP TO LIKE NEW CONDITION)16. REMOVE EXISTING REVEAL, PATCH WALL TO BE FLUSH WITH REMAINDER OF CYBERSECURITY LAB WALL17. EXISTING LIGHTING AND HVAC SUPPLY AND RETURN GRILLES TO BE REMOVED AND REPLACED. VERIFY QUANTITIES AND CONFIGURATION 18. REMOVE WALL COVERING AND REPAIR GYPSUM WALL BOARD WHERE NECESSARY. PREPARE WALL FOR NEW FINISHES19. EXISTING REVEALS TO REMAIN AND BE REPAINTED20. REMOVE EXISTING PROJECTOR AND TURN OVER TO OWNER21. EXISTING FIRE EXTINGUISHER CABINET TO BE REMOVED AND RE-LOCATED PER NEW CONSTRUCTION DRAWINGS22. EXISTING COLUMN WRAP TO BE DEMOLISHED AND RE-WRAPPED PER NEW CONSTRUCTION DRAWINGS; IF COLUMN CONTAINS NO
STRUCTURE DO NOT REPLACE, COLUMN IS TO BE ELIMINATED COMPLETELY23. EXISTING FLOORING TO BE REMOVED AND FLOOR IS TO BE CLEANED AND PREPARED TO RECEIVE SCHEDULED FLOORING24. CEILING REMOVED AND REINSTALLED AS REQUIRED FOR MODIFICATIONS OF PLUMBING & ELECTRICAL IN SPACE ABOVE. 25. EXISTING COLUMN WRAP TO REMAIN, PREPARE SURFACES TO RECEIVE NEW PAINT FINISHES.26. EXISTING STRUCTURE AND ROOF LEADER TO REMAIN
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
3/9/
2020
7:5
9:04
AM
A0.1
DEM
OLI
TIO
N P
LAN
-FI
RST
FLO
OR
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LWF
02-25-2020
FPA #07519
RS
100 % CDs
121
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
NORTH
1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
KEY PLAN
0' 4' 8' 16' 32'
REVISIONS
1 Addendum #1 MARCH 9, 2020
1
DNDN
UP
A. PRE-DEMOLITION MEETING: PRIOR TO THE ACTUAL START OF DEMOLITION WORK, THE CONTRACTOR SHALL SCHEDULE A PRE-DEMOLITION MEETING. THIS MEETING SHALL BE ATTENDED BY THE ARCHITECT, CONTRACTOR, SUPERINTENDENT, DEMOLITION FORMAN, AND OWNER. THE MEETING SHALL BE HELD AT THE CONSTRUCTION SITE. THE PURPOSE OF THE MEETING IS TO REVIEW THE SCOPE OF DEMOLITIONAND ALL ITEMS TO BE SALVAGED DURING DEMOLITON. THE CONTRACTOR SHALL PROVIDE A SET OF PLANS FOR THE MEETING. THE PLANS SHALL BE USED TO REVIEW AND MARK SPECIFIC ITEMS OF QUESTION. ALL ITEMS SHALL BE RESOLVED AND PART OF THE RECORD MINUTES TO BE DISTRIBUTED TO ALL PARTIES FOR RECORD. NO DEMOLITION SHALL OCCUR UNTIL THIS MEETING HAS BEEN CONDUCTED.
B. DEMOLITION DRAWINGS: DEMOLITION DRAWINGS ILLUSTRATE THE GENERAL SCOPE OF DEMOLITION WORK TO BE PERFORMED AND ARE NOT INTENDED TO BE COMPREHENSIVE OR ALL-INCLUSIVE. THE CONTRACTOR SHALL PERFORM THE DEMOLTION WORK INCLUDED IN THE DEMOLITION PLANS AND ITS ASSOCIATED CONSTRUCTION, ALONG WITH ANY AND ALL DEMOLITION REQUIRED FOR THE SUCCESSFUL COMPLETION OF THE NEW CONSTRUCTION WORK TO BE PERFORMED, INCLUDING THAT REQUIRED OF ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND SIMILAR APPLICABLE SUB-CONTRACTOR WORK.
C. TEMPORARY BRACING: PRIOR TO REMOVAL OF EXISTING STRUCTURAL ELEMENTS, THE CONTRACTOR SHALL TEMPORARILY SHORE AND/OR BRACE EXISTING CONSTRUCTION TO REMAIN AS REQUIRED TO SUPPORT EXISTING LOADS AND/OR LOADS IMPOSED DURING CONSTRUCTION.
D. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, CONSTRUCTION, MATERIALS, METHODS OF CONSTRUCTION, ELEVATIONS, ETC. PRIOR TO BIDDING, CONSTRUSTION, AND INSTALLATION. NOTIFY ARCHITECT OF ANY CONDITIONS WHICH MAY IMPACT THE BID, INCLUDING BUT NOT LIMITED TO CONCEALED CONDITIONS AFFECTING THE WORK AND ANY DISCREPANCIES WITHIN DOCUMENTS OR ENCOUNTERED DURING CONSTRUCTION PRIOR TO PROCEEDING WITH WORK.
E. ALL WORK SHALL BE COORDINATED WITH THE WORK OF OTHER TRADES TO AVOID INTERFERENCES AND CONFLICTS. REFER TO THE DRAWINGS OF THE RESPECTIVE SYSTEMS PRIOR TO SUBMISSION OF BIDS FOR ADDITIONAL WORK WHICH MAY BE REQUIRED AS PART OF THEIR WORK. NO ALLOWANCES WILL BE MADE FOR THE LACK OF COORDINATION BETWEEN DISCIPLINES OR SYSTEMS AND EQUIPMENT.
F. THE CONTRACTOR SHALL TAKE EXTREME CAUTION TO FULLY INVESTIGATE EXISTING FINISHES, CONSTRUCTION, MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS PRIOR TO DEMOLITION TO ASSURE CRITICAL SERVICES ARE NOT INTERRUPTED.
G. IT IS THE CONTRACTORS RESPONSIBILTY TO BARRICADE OFF AREA OF WORK AND PROVIDE PROTECTED ENTRANCES AND EXITS TO AND FROM THE BUILDING. DO NOT BLOCK EXITS.
H. PROJECT PLANS HAVE BEEN DEVELOPED FROM DRAWINGS PREVIOUSLY PREPARDED BY OTHERS. ACTUAL CONDITIONS MAY VARY. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS RELATED TO EXISTING CONSTRUCTION AND MAKE MINOR ADJUSTMENTS AS REQUIRED. CONTRACTOR SHALL REPORT ANY DIFFERENCES TO THE ARCHITECT PRIOR TO BIDDING.
I. IT IS THE CONTRACTORS SOLE RESPONSIBILITY DURING DEMOLITION TO PROVIDE PROTECTION FOR ALL EXISTING CONSTRUCTION TO REMAIN. CONTRACTOR TO PATCH, REPAIR, AND REPLACE ANY AND ALL EXISTING CONSTRUCTION DAMAGED BY THE DEMOLITION, INCLUDING BUT NOT LIMITED TO: EXISTING STRUCTURE, FINISHES, CEILINGS. THE CONTRACTOR SHALL ALSO PROVIDE PROTECTIVE BARRIERS FROM DUST AND WEATHER DURING DEMOLITION SO AS NOT TO DAMAGE EXISTING CONSTRUCTION INDICATED TO REMAIN.
J. THE CONTRACTOR IS RESPONSIBLE FOR ANY ADDITIONAL DEMOLITION REQUIRED FOR THE COMPLETION OF THE WORKS AS DESCRIBED IN THE CONTRACT DOCUMENTS. THESE ITEMS INCLUDE BUT ARE NOT LIMITED TO: PIPING, WIRING, ETC. ANY CLARIFICATION REQUIRED SHALL BE OBTAINED FROM THE ARCHITECT, IN WRITING.
K. IT IS THE INTENT THAT WHERE NEW WORK IS INDICATED, THAT SOME EXISTING FINISHES, MATERIALS, ETC. SHALL BE REMOVED AS NECESSARY AND PRACTICAL TO INSTALL THE NEW WORK. ALL ADJACENT WALLS, CEILINGS, FLOORS, FINISHES, ETC. SHALL BE PREPARED AS REQUIRED TO RECEIVE NEW WORK.
L. EXISTING VCT TO REMAIN, UNLESS NOTED OTHERWISE.M. WHEN FLOORING IS TO BE REMOVED THE CONTRACTOR SHALL PROVIDE IN THE BASE BID ANY AND ALL COSTS ASSOCIATED WITH THE
REMOVAL OF THE EXISTING FLOORING SYSTEMS, DAMAGED SUBSTRATES, AND ANY OTHER ASSOCIATED CONSTRUCTION. THE BASE BID SHALL ALSO INCLUDE THE PATCHING, REPAIR AND LEVELING OF ANY EXISTING SUBSTRATE TO RECEIVE NEW FLOORING SYSTEMS.
N. CODE COMPLIANCE: PERFORM ALL WORK IN STRICT ACCORDANCE WITH APPLICABLE LAWS, CODES, AND ORDINANCES.O. SECURE NECESSARY PERMITS AND APPROVALS FOR WORK IN AND ADJACENT TO CITY RIGHT-OF-WAYS. P. ALL DUCTWORK, PIPING AND CONDUIT SCHEDULED FOR SELECTIVE DEMOLITION SHOULD INCLUDE COMPLETE REMOVAL INCLUDING
ALL HANGERS, SUPPORTS, TECH.Q. REMOVE ALL EXISTING BASE TRIM, WAINSCOT TRIM, FLOORING, WALL COVERING, AND WALL ACCESSORIES WITHIN THE SCOPE OF
WORK AREA.
DEMOLITION/CONSTRUCTION NOTES
EXISTING WALLS TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
DEMOLITION KEY NOTES
WALLS TO BE MODIFIED
EXTENT OF CEILING RENOVATION
BEYOND EXTENT OF RENOVATION
EXISTING FIXTURES TO BE DEMOLISHED
DEMOLITION PLAN LEGEND
2
1. REMOVE AND REPLACE EXISTING CEILING. SEE RCP DEMOLITION PLAN FOR ADDITIONAL INFORMATION2. EXISTING EXIT LIGHTS, FIRE PULL, PUSH TO EXIT BOXES, AND THERMOSTAT TO BE REMOVED. RELOCATE ANY DEVICES AS INDICATED ON
ELECTRICAL ENGINEERING DRAWINGS3. EXISTING STEEL COLUMN AND RAIN WATER LEADER TO REMAIN4. EXISTING MARKER BOARD, WALL CLOCK, PROJECTION EQUIPMENT, VOICE AMPLIFICATION EQUIPMENT AND ACCESSORIES TO BE
REMOVED AND TURNED OVER TO OWNER.5. EXISTING HVAC UNIT TO REMAIN. REFER TO MECHANICAL DRAWINGS FOR DETAILS.6. EXISTING ELECTRICAL PANELS TO REMAIN7. EXISTING WATER COOLER TO BE REMOVED AND LINES CAPPED OR REROUTED TO NEW WATER COOLER LOCATION, PER ENGINEERING
DRAWINGS.8. REMOVE EXISTING CASEWORK AND TURN OVER TO OWNER9. DEMOLISH EXISTING WOOD SHELVING10. REMOVE EXISTING WALL-MOUNTED ELECTRICAL RACEWAY11. EXISTING THERMOSTAT. RELOCATE PER ENGINEERING DRAWINGS12. REMOVE EXISTING TELEVISION WALL MOUNT AND TURN OVER TO OWNER13. EXISTING CEILING GRID TO REMAIN. CEILING TILES TO BE REPLACED. 14. EXISTING LIGHTING TO BE RE-USED IF FIXTURES ARE LED, IF NOT REPLACE WITH LED FIXTURES AND INSTALL PER ELECTRICAL
ENGINEERING DRAWINGS.15. SALVAGE EXISTING DOORS FOR POSSIBLE RE-USE. (IF DOORS ARE TO BE RE-USED TOUCH UP TO LIKE NEW CONDITION)16. REMOVE EXISTING REVEAL, PATCH WALL TO BE FLUSH WITH REMAINDER OF CYBERSECURITY LAB WALL17. EXISTING LIGHTING AND HVAC SUPPLY AND RETURN GRILLES TO BE REMOVED AND REPLACED. VERIFY QUANTITIES AND CONFIGURATION 18. REMOVE WALL COVERING AND REPAIR GYPSUM WALL BOARD WHERE NECESSARY. PREPARE WALL FOR NEW FINISHES19. EXISTING REVEALS TO REMAIN AND BE REPAINTED20. REMOVE EXISTING PROJECTOR AND TURN OVER TO OWNER21. EXISTING FIRE EXTINGUISHER CABINET TO BE REMOVED AND RE-LOCATED PER NEW CONSTRUCTION DRAWINGS22. EXISTING COLUMN WRAP TO BE DEMOLISHED AND RE-WRAPPED PER NEW CONSTRUCTION DRAWINGS; IF COLUMN CONTAINS NO
STRUCTURE DO NOT REPLACE, COLUMN IS TO BE ELIMINATED COMPLETELY23. EXISTING FLOORING TO BE REMOVED AND FLOOR IS TO BE CLEANED AND PREPARED TO RECEIVE SCHEDULED FLOORING24. SALVAGE EXISTING METAL REVEALS TO BE REUSED IF POSSIBLE.25. EXISTING COLUMN WRAP TO REMAIN, PREPARE SURFACES TO RECEIVE NEW PAINT FINISHES.26. EXISTING STRUCTURE AND ROOF LEADER TO REMAIN
DEMOLITION KEY NOTES#
AIR RETURN (V.I.F.)
AIR SUPPLY (V.I.F.)
UP
WOMEN
PBX
EXIST.CORRIDOR
COMPUTERCLASSROOM
EXIST.BALCONY
MENEXISTING
ELEC.
EXIST.CLASSROOM
EXIST. CORRIDOR211
RECEPTION
EXISTINGPORCH
EX. SERVER ROOM238
EXISTING CORRIDOR231
EXISTINGCLOSET
EXIST.JANITOR EXIST.
COPY RM
EXIST.ELEV.
EXISTINGMECHANICAL
EXIST.ELEV.
EXISTINGMECHANICAL
EXIST.CLASSROOM
EXIST.CLASSROOM
CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
OFFICE
OFFICESECRETARY
CONFERENCEROOM
STOR.
TOIL.
OFFICE
STAIRS
EXIST. CORRIDOR207
18 19
18 19
EXIST. CLASSROOM
EXIST. LAB
4 18 20 410 18 2010
EXIST. GRAD STUDENTLOUNGE
22
22
21
7
LAB
LAB
2222
22
18 19
23
23 23
4 18 2010 23
18 20 23
18 19CARPET AND TILE FLOORING TO BE REMOVED UP TO THIS LINE
EXIST. SITTING AREA
17
17
1
171
171
1
1 114
14
14
4 101 14
EXIST. CLASSROOM
1
15
AIRLOCK233
18 19171
15
15 15
15
24
24
25
WALLCOVERING TO REMAIN13'-3" EXISTING
26
DOWN
DOWN
DN
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:14:
46 A
M
A0.2
DEM
OLI
TIO
N P
LAN
-SE
CO
ND
FLO
OR
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
122
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
NORTH
1/8" = 1'-0"
SECOND FLOOR DEMOLITION PLAN
KEY PLAN
0' 4' 8' 16' 32'
REVISIONS
UP
DN
SHADED AREAS ARE EXISTING TO REMAIN (NO WORK)
REMOVE EXISTING WALLCOVERING, AND REFINISH WALLS IN EXISTING CORRIDORS. EXISTING GYP. REVEALS ARE TO REMAIN. REPLACE EXISTING CEILING AND LIGHTING
REMOVE EXISTING WALLCOVERING, AND REFINISH WALLS IN EXISTING CORRIDORS. EXISTING GYP. REVEALS ARE TO REMAIN. REPLACE EXISTING SUSPENDED CEIILING AND LIGHTING
COMPUTERCLASSROOM
EXIST.CLASSROOM
EXIST. LAB
EXIST. LAB
EXISTINGPORCH
EXIST.CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
CLASSROOM
STAIR
CORRIDOROFFICE
OFFICE
OFFICE SECRETARYCONFERENCE
ROOM
RECEPTION EXIST.CORRIDOR
EXIST.BALCONY
EXIST.CORRIDOR
EXISTINGMECHANICAL
CYBERSECURITYLAB
CYBERLOUNGE
LABSUPPORT
STAIRS
EXIST.CORRIDOR
SHADED AREAS ARE EXISTING TO REMAIN (NO WORK)
REPAIR AND PATCH CEILING AND FLOOR WHERE COLUMNS ARE REMOVED OR MODIFIED - SEE FINISH FLOOR PLAN FOR TILE DETAILS
WORK IN THIS AREA LIMITED TO REMOVAL OF CEILING AS REQUIRED FOR ABOVE CEILING WORK. EXISTING CEILING TO BE STORED AND REINSTALLED ONCE WORK IS COMPLETE
EXISTINGAUDITORIUM
EXISTINGCASE
ROOM #5
EXISTINGCASE
ROOM #4
EXISTINGCASE
ROOM #1
EXISTINGCASE
ROOM #2
EXISTINGCASE
ROOM #3
EXISTINGATRIUMLOBBY
WOMEN
MEN
EXISTINGTRADE LAB
EXISTINGSTUDY
RESOURCE
EXISTINGMECHANICAL
EXIST.CONF.
EXIST.CONF.
EXISTINGCORRIDOR
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXIST.WORKROOM
ADMIN.
EXISTINGRECORD
EXISTINGSTAIR
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGCORRIDOR
B.S.CONTROL
BEHAV.SCIENCE
STUDYALCOVE
EXISTINGTEAM
EXISTINGTEAM
EXISTINGTEAMEXISTING
TEAM
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:15:
09 A
M
A1.0
GEN
ERAL
INFO
RMAT
ION
FIR
ST A
ND
SEC
ON
D F
LOO
R PL
ANS
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
123
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
0' 2' 4 8' 16'
KEY PLAN
REVISIONS
NORTH
1/16" = 1'-0"
SECOND FLOOR PLAN - GENERAL INFORMATIONNORTH
1/16" = 1'-0"
FIRST FLOOR PLAN - GENERAL INFORMATION
EXISTINGCASE
ROOM #1
EXISTING TEAM117
EXISTING TEAM116
EXISTING TEAM118
EXISTING TEAM119
EXISTINGCASE
ROOM #3
EXISTINGMECHANICAL
EXISTINGTEAM
EXISTINGCASE
ROOM #2EXISTING STAIR101
EXISTINGRECORD
EXISTINGRECEPTION
STUDYALCOVE
EXIST. CORRIDOR115
EXIST. CORRIDOR115
EXISTING CORRIDOR146
EXISTING STUDYRESOURCE
150
EXISTING TRADE LAB147
WOMEN
MEN
EXISTINGATRIUMLOBBY
EXISTING CORRIDOR125
EXISTING CORRIDOR125
EXISTINGAUDITORIUM
EXISTINGMECHANICAL
EXIST. JAN.
EXISTINGCASE
ROOM #4
EXISTINGCASE
ROOM #5
EXIST.ELEV.
BEHAV.SCIENCE
B.S.CONTROL
EXISTINGOFFICEEXISTING
OFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXIST.WORKROOM
EXISTINGOFFICE
EXISTINGOFFICE
EXIST.CONF.
EXIST.CONF.
EXISTINGCORRIDOR
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTING STAIRS256
EXISTING CORRIDOR137
REPAIR AND PATCH CEILING AND FLOOR AT NEW COLUMN DETAIL - SEE FINISH FLOOR PLAN FOR TILE DETAILS
REPAIR AND PATCH CEILING AND FLOOR WHERE COLUMN WAS REMOVED - SEE FINISH FLOOR PLAN FOR TILE DETAILS
REPAIR AND PATCH CEILING AND FLOOR WHERE COLUMN WAS REMOVED - SEE FINISH FLOOR PLAN FOR TILE DETAILS
AIRLOCK146A
1
REPAIR AND PATCH CEILING AND FLOOR WHERE COLUMN WAS REMOVED - SEE FINISH FLOOR PLAN FOR TILE DETAILS
WORK IN THIS AREA LIMITED TO REMOVAL OF CEILING ONLY AS REQUIRED FOR ABOVE CEILING WORK. EXISTING CEILING TO BE STORED AND REINSTALLED ONCE WORK IS COMPLETE
CONFERENCE149
A6.0
9
EXIST.ELECT.
PBX
MAIL RM
EXIST.ELEV.
EXISTINGOFFICE
ADMIN.
EXIST.CORRIDOR
1
1
EXIST. AVBOOTH
EXIST.CLOSET
EXIST.STORAGE
EXIST.ELECT.
1
1
1
1
GENERAL RENOVATION NOTESA. EXISTING ROUND COLUMN WRAPS AND BASE TO BE REMOVEDB. EXISTING CEILING AND LIGHTING TO REMAINC. EXISTING CEILING TO BE REPAIRED AND PATCHED AFTER COLUMN WRAP REMOVALD. EXISTING FLOOR TILE TO BE SAW CUT AT EXISTING ROUND COLUMNS AFTER REMOVAL TO CREATE NEW PATTERN - SEE COLUMN COVER REMOVAL
DETAIL BELOW FOR GENERAL LAYOUT
RENOVATION PLAN LEGEND
EXISTING CONSTRUCTION TO REMAIN
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
3/9/
2020
7:5
9:23
AM
A1.1
FIRS
T FL
OO
R -O
VERA
LL R
ENO
VATI
ON
PLA
N301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LWF
02-25-2020
FPA #07519
RS
100 % CDs
124
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
NORTH
1/8" = 1'-0"
FIRST FLOOR - OVERALL RENOVATION PLAN
0' 4' 8' 16' 32'
KEY PLAN
1
1
REVISIONS
1 Addendum #1 MARCH 9, 2020
UP
OPEN TO BELOW
EXIST.BALCONY
COMPUTERCLASSROOM
206
PBX
MEN
EXISTINGELEC.
EXIST. CLASSROOM209
WOMEN
UP
DN
EX
EXISTINGCLOSET
EX
EX
EX
EXISTINGCORRIDOR
231
EXISTINGPORCH
UTILITY
EXIST. CORRIDOR211
RECEPTION
STAIR201
EXIST.JANITOR EXIST.
COPY RM
EXIST.ELEV.
EXISTINGMECHANICAL
EXIST.ELEV.
EXISTINGMECHANICAL
EXIST. CLASSROOM232C
EXIST. CLASSROOM205
CLASSROOM243
102 SF
LABSUPPORT
217
EXIST. CLASSROOM220
EXIST. CLASSROOM224
EXIST. CLASSROOM222
RECORDSOFFICE
OFFICE
OFFICESECRETARY
CONFERENCEROOM
STOR.
TOIL.
OFFICE
STAIRS219
CORRIDOR
EX EX
EX
EXEX
EX
EX
EX
EX
EX
EX EX
EX
EX
EX
EX EX
EXEXEX
EX
EX
EX
EX
EX
EX
CYBER LOUNGE218
CYBERSECURITY LAB219
219A
219B 217
EX
EX
EX
EX
EX
EX
1 1NEW COLUMN WRAPSSEE DETAILS ON A
A1.2a
1
1
8'-5 1/4" 26'-8 1/2" 10'-5"
7'-10
1/4
"
9'-11
"
23'-6
1/4
"34
'-1"
222 2
A6.0
5
A6.0
12
3
NEW WATER FOUNTAIN / BOTTLE FILLER
RELOCATEDFIRE EXTIGUISHER CABINET
EXIST.CORRIDOR
207
EX
A6.07
A6.0
8
PNT-4
PNT-4
PNT-4
PNT-4
PNT-4
PNT-4
AIRLOCK233
TECH COUNTER
RACK5'-0"
EX
3
6
DN
EXIST. LAB244
EXIST. LAB258
15A6.0
15A6.0
1
OFFICE
EXISTING SERVER RM.
RENOVATION PLAN LEGEND
EXISTING TO REMAIN
GENERAL RENOVATION NOTESA. WHERE SCHEDULE, DOOR FRAMES (ON RENOVATION SIDE) TO BE PAINTED PNT-2. ONLY FRAMES TO BE PAINTED. DOORS SHOULD REMAIN
UNPAINTEDB. WITHIN RENOVATED AREAS OR AS INDICATED ON SCHEDULE, ALL EXISTING ROOM SIGNS, PLAQUES, AND PORTRAITS TO BE CAREFULLY REMOVED,
THEN REPLACED ONCE WALLS HAVE BEEN PAINTED. (IF SIGNAGE ALTERNATE IS NOT ACCEPTED)C. WITHIN RENOVATED AREAS, ALL EXISTING ARTWORK TO BE CAREFULLY REMOVED AND TURNED OVER TO THE UNIVERSITY.D. WITHIN RENOVATED AREAS, REMOVE EXISTING WALL COVERING AND REPAIR GYPSUM WALL BOARD WHERE NECESSARY. PREPARE WALL FOR NEW
FINISHESE. WITHIN RENOVATED AREAS, EXISTING METAL REVEALS TO REMAIN AND BE PAINTED PNT-2F. WITHIN RENOVATED AREAS, ALL HARD TILE BASE IS TO REMAIN UNLESS OTHERWISE NOTED.G. WITHIN RENOVATED AREAS, OR AS INDICATED ON SCHEDULE, INTERIOR SIDE OF WINDOW TRIM TO BE PAINTED PNT-2.H. WITHIN RENOVATED AREAS, EXISTING INTERIOR UNPAINTED BRICK ARE TO BE CLEANED AND PAINTED PNT-1.
THIS DRAWING IS INTENDED TO SHOW GENERAL LOCATIONS OF INTERIOR WALL TYPES. REFER TO OTHER DRAWINGS FOR SPECIFIC WALL CONSTRUCTION, INCLUDING LOCATION OF APPLIED FINISHES. REFER TO WALL SECTIONS AND DETAILS FOR INFORMATION REGARDING CONSTRUCTION OF EXTERIOR WALLS.
3 5/8" METAL STUDS WITH 3/4" PLYWOOD ON ALL SIDES, EXTEND 6" ABOVE CEILING. SEE DETAIL 9/A6.0 FOR WALL CONSTRUCTION.
3 5/8" METAL STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYP.BD. ON TWO SIDES, EXTEND TO DECK AND SEAL
3 5/8" METAL STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYP.BD. ON ONE SIDE, WALL TO EXTEND 6" ABOVE CEILING
INTERIOR PARTITION NOTES
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
3/9/
2020
7:5
9:38
AM
A1.2
SEC
ON
D F
LOO
R -O
VERA
LL R
ENO
VATI
ON
PLA
N
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
125
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
NORTH
1/8" = 1'-0"
SECOND FLOOR - OVERALL RENOVATION PLAN
0' 4' 8' 16' 32'
KEY PLAN
1
2
3
REVISIONS
1 Addendum #1 MARCH 9, 2020
1
1
EXIST.CLASSROOM
232C
EXIST. CLASSROOM220
STAIRS219
CEILING MOUNTED MONITORS
217
1906 SF
CYBERSECURITYLAB219
102 SF
LABSUPPORT
217219B
219A
CEILING MOUNTED MONITOR
657 SF
CYBER LOUNGE218
WALL MOUNTED MONITORS
WALL MOUNTED MONITOR
WALL MOUNTED MONITOR
ALIGN WALL WITH EXISTING VERTICAL MULLION
8'-0"
26'-6 1/2" 10'-5" 13'-3"
21'-6" 16'-3"
12'-9
1/2
"
POWER AND DATA FLOOR BOXES(ES)
POWER AND DATAFLOOR BOX
POWER AND DATA FLOOR BOX
DEMOUNTABLE WALL WITH FULL HEIGHT GLASS (TO BE INCLUDED IN FURNITURE PACKAGE)
15'-9
"
POWER AND DATA FLOOR BOX
GLASS WALLHOLD OPENING TO 26'-4 1/4"
A6.0
5
A6.0
1
ROLLER SHADES AT ALL WINDOWS IN LAB - SEE 1/A7.0 FOR EXTENTS
ROLLER SHADES AT ALL WINDOWS IN LAB - SEE 1/A7.0 FOR EXTENTS
7'-7
1/2"
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITORS
ROLLER SHADES AT ALL WINDOWS IN LAB - SEE 1/A7.0 FOR EXTENTS
23
NEW WATER FOUNTAIN / BOTTLE FILLER
RELOCATEDFIRE EXTIGUISHER CABINET
A6.0
16
ACCESS CONTROLLED DOOR (BADGE IN ONLY)
ACCESS CONTROLLED DOOR (BADGE IN ONLY)
ACCESS CONTROLLED DOOR (BADGE IN ONLY)
15'-6 1/2" 12'-10"
A6.07
A6.0
8
(ver
if y)
9'-11
"
ROLLER SHADES AT ALL WINDOWS IN LAB - SEE 1/A7.0 FOR EXTENTS
MANUAL ROLLER SHADES AT ALL WINDOWS IN LOUNGE - SEE 1/A7.0 FOR EXTENTS
EXISTING STRUCTURAL COLUMN AND ROOF LEADER
RACK5'-0"
12A6.0
10A6.0
15A6.0
12A6.0
15A6.0
A6.0
9
15'-2"
A1.2a
A
6
A6.0
4
3"
15A6.0
12A6.0
15A6.0
sim.
GENERAL RENOVATION NOTESA. WHERE SCHEDULE, DOOR FRAMES (ON RENOVATION SIDE) TO BE PAINTED PNT-2. ONLY FRAMES TO BE PAINTED. DOORS SHOULD REMAIN
UNPAINTEDB. WITHIN RENOVATED AREAS OR AS INDICATED ON SCHEDULE, ALL EXISTING ROOM SIGNS, PLAQUES, AND PORTRAITS TO BE CAREFULLY REMOVED,
THEN REPLACED ONCE WALLS HAVE BEEN PAINTED. (IF SIGNAGE ALTERNATE IS NOT ACCEPTED)C. WITHIN RENOVATED AREAS, ALL EXISTING ARTWORK TO BE CAREFULLY REMOVED AND TURNED OVER TO THE UNIVERSITY.D. WITHIN RENOVATED AREAS, REMOVE EXISTING WALL COVERING AND REPAIR GYPSUM WALL BOARD WHERE NECESSARY. PREPARE WALL FOR NEW
FINISHESE. WITHIN RENOVATED AREAS, EXISTING METAL REVEALS TO REMAIN AND BE PAINTED PNT-2F. WITHIN RENOVATED AREAS, ALL HARD TILE BASE IS TO REMAIN UNLESS OTHERWISE NOTED.G. WITHIN RENOVATED AREAS, OR AS INDICATED ON SCHEDULE, INTERIOR SIDE OF WINDOW TRIM TO BE PAINTED PNT-2.H. WITHIN RENOVATED AREAS, EXISTING INTERIOR UNPAINTED BRICK ARE TO BE CLEANED AND PAINTED PNT-1.
RENOVATION PLAN LEGEND
EXISTING TO REMAIN
THIS DRAWING IS INTENDED TO SHOW GENERAL LOCATIONS OF INTERIOR WALL TYPES. REFER TO OTHER DRAWINGS FOR SPECIFIC WALL CONSTRUCTION, INCLUDING LOCATION OF APPLIED FINISHES. REFER TO WALL SECTIONS AND DETAILS FOR INFORMATION REGARDING CONSTRUCTION OF EXTERIOR WALLS.
3 5/8" METAL STUDS WITH 3/4" PLYWOOD ON ALL SIDES, EXTEND 6" ABOVE CEILING. SEE DETAIL 9/A6.0 FOR WALL CONSTRUCTION.
3 5/8" METAL STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYP.BD. ON TWO SIDES, EXTEND TO DECK AND SEAL
3 5/8" METAL STUDS AT 16" O.C. WITH ONE LAYER 5/8" GYP.BD. ON ONE SIDE, WALL TO EXTEND 6" ABOVE CEILING
INTERIOR PARTITION NOTES
5/8" GYPSUM WALL BOARD ON METAL STUD FRAMING AS SCHEDULED. CENTER WALL ON STOREFRONT MULLION
COMPRESSED CLOSED CELL FOAM W/ ADHESIVE TO MATCH FRAMING IN WIDTH TO SEAL ALL CAPS
BREAK METAL TRIM TO MATCH STOREFRONT HEM EDGES - BREAK PAST 90 DEGREES FOR TENSION FIT
1 1/2"
INSIDE FACE OF CURTAIN WALL FRAME BELOW
EXISTING CURTAIN WALL MULLION
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
3/9/
2020
8:0
0:04
AM
A1.2a
CYB
ERSE
CU
RITY
LAB
-EN
LARG
ED S
ECO
ND
FLO
OR
PLAN
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LWF
02-25-2020
FPA #07519
RKS
100 % CDs
126
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
NORTH
1/4" = 1'-0"
SECOND FLOOR - CYBERSECURITY LAB - ENLARGED PLAN
0' 2' 4 8' 16'
KEY PLAN
REVISIONS
1 Addendum #1 MARCH 9, 2020
A1.2a 3" = 1'-0"
A PARTITION INTERSECTING MULLION
1
2
3
1
1
1
1
1
65" MONITORS
5'-8
1/2"
4'-11" 4'-2 1/4"
PL-1, PLASTIC LAMINATE COUNTERTOP W/ 4" BACKSPLASH
WALL MOUNTED POWER AND DATA MODULE
INSIDE WALL MOUNT SUPPORT BRACKETS AS NEEDED
FRL-1 WITH PROTECTIVE OUTSIDE CORNER BEADS TO MATCH
RB-1
30"
11A6.0
PNT-4
1-1/2" LAMINATED DOUBLE EASED EDGE
4A6.0
5'-10
"
85" MONITOR
7'-2"
RB-1
PNT-1
EXISTING REVEALS TO BE PAINTED PNT-2
EXISTING WINDOW FRAME / SILL TO BE SANDED AND PAINTED PNT-1
33 7
/8"
3/4"
40"
3/4"
41 5
/8"
PNT-1
SPECIFIED ROLLER SHADE WITH METAL FASCIA PAINTED PNT-2
5'-10
"
85" MONITOR
EXISTING BRICK TO BE PAINTED PNT-1
PNT-4
EXISTING DOOR / TRIM TO BE PAINTED PNT-2
RB-1
6"
GLASS WALLHOLD OPENING TO 26'-4 1/4" 8'-4 1/2"
DONORSIGNAGE
GYP BULKHEAD TO BE EXTENDED TO DECKSEE DETAIL 10/A6.0
RB-1
PNT-1
10A6.0
7'-6"
2'-0"
WALL BY OTHERS
HO
LD O
PENI
NG T
O 9
'-9"
2'-6"
REFER TO ELEVATION FOR COUNTERTOP MATERIAL - SEE PLAN VIEW FOR SHAPE
INSIDE WALL MOUNT SUPPORT BRACKETS AS NEEDED(CENTERLINE BRACKETS -COUNTER SUPPORT - FRONT MOUNTING PLUS)
GROMMET LOCATIONS PER OWNERS REQUEST / QUANTITY OF 4 MIN.
SCHEDULED WALL BASE
5/8" GYP
4"
FRL ON 3/4" PLYWOOD SUBSTRATE
1 1/
2"
1-1/2" LAMINATED DOUBLE EASED EDGE
ACOUSTICAL PANEL CEILING
*SEE REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND DIMENSIONS
EXISTING WOOD SILL AND TRIM TO REMAIN - SAND AND PAINT PER ELEVATION
SPECIFIED ROLLER SHADE WITH METAL FASCIA PAINTED PER ELEVATIONS
ACOUSTICAL PANEL CEILING
CORNER BEAD EA. SIDE, TYP
BULKHEAD - 3-5/8" METAL STUD FRAMING #16" O.C. WITH 5/8" GWB. EXTEND METAL STUDS TO ROOF DECK. PROVIDE DIAGONAL BRACES AT 48" .C. FROM STUDS TO EXISTING STRUCTURE. WHERE ADJACENT CEILING IS APC, EXTEND GWB 6" ABOVE FINISHED CEILING. WHERE THE ADJACENT SPACE IS EXPOSED TO STRUCTURE, EXTEND GWB TO STRUCTURE.
SEE REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND DIMENSIONS
WALL TO EXTEND TO DECK, TYP.
5"
DEMOUNTABLE WALL WITH FULL HEIGHT GLASS (TO BE INCLUDED IN FURNITURE PACKAGE)
BRACING TO DECK REQUIRED
CONTINUOS BLOCKING ABOVE DEMOUNTABLE WALL
METAL CORNER BEAD (TIGHT TO BRICK)
EXISTING BRICK VENEER AFTER DEMO
V.I.F
1-1/2" STUD WITH 5/8" GYP ON ONE SIDE
EXISTING STAIRWELL
6'-9"7'-
11"
SEE DETAILS 9,13,14/A6.0 FOR COLUMN FINISH
CEILING MOUNTED TV
9A6.0
FRL-1 ON 1/2" SUBSTRATE
FRY REGLET MILLWORK CHANNEL WITH RETURN KEYS, INSTALLED HORIZONTALLY ONLY, HORIZONTAL REVEALS TO ALIGN WITH EXISTING REVEALS ON ADJACENT WALLS
4" MILLWORK REVEAL BASE WITH RETURN KEY
HALLWAYS: BLACK FLOOR TILE. SEE FINISH FLOOR PLAN FOR EXTENTS
RB-1
PNT-1
EXISTING WINDOW FRAME / SILLS TO BE PAINTED PNT-2
PNT-1
WC-1 AND FASCIA TO BE CEILING MOUNTED TO UNDERSIDE OF BULKHEAD
V.I.F
.33
7/8
"2
1/2"
V.I.F
.35
3/4
"2
1/2"
V.I.F
.42
3/8
"
PNT-1
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
EXISTING WINDOW FRAME / SILL TO BE SANDED AND PAINTED PNT-1
12A6.0
15A6.0
PNT-1
TYPI
CAL
7'-5"
ACOUSTICAL PANEL CEILING
*SEE REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND DIMENSIONS
SPECIFIED TV MOUNT CEILING PLATE
STEEL PLATE OR BLOCKING TO BE SECURED TO DECK OR STRUCTURE ABOVE FOR ATTACHEMENT OF TV MOUNT
DECORATIVE TILE RING, WHITE
SPECIFIED CEILING TV MOUNT
SPECIFIED ROLLER SHADE WITH METAL FASCIA PAINTED PER ELEVATIONS
EXISTING THIRD FLOOR SLAB
EXISTING EXTERIOR WALL
EXISTING EXTERIOR CURTAIN WALL
(FINAL SIZE TBD IN FIELD)1'-6 1/4"
EXISTING STEEL COLUMN
3 5/8" METAL STUDS
3/4" PLYWOOD
FRL-1 APPLIED TO 1/2" AC PLYWOOD FRY REGLET
MILLWORK CORNER KEY
1/2"
1/4"
3/4"
3 3/4"
*ALSO SEE DETAILS 13 & 14/A6.0 FOR ADDITIONAL INFORMATION
SOME COLUMN WRAPS ARE TO INCLUDE ROOF DRAIN PIPE IN ADDITION TO STRUCTURAL COLUMN
PL-1, PLASTIC LAMINATE COUNTERTOP W/ 4" BACKSPLASH
INSIDE WALL MOUNT SUPPORT BRACKETS AS NEEDED FRL-1 FRL-1 WITH
PROTECTIVE OUTSIDE CORNER BEADS TO MATCH
RB-1
11A6.0
4A6.0
WINDOW BEYOND
PNT-1
93.07°
2'-6"
2'-10
1/4
"
2'-4"
R 0'-8 3
/8"
R 0'-9 1/32"
12'-10 3/4"
7'-1
1/4"
10'-4 3/4"
TECH COUNTER
1'-9"
KNEE WALL TO BE WRAPPED IN SPECIFIED LAMINATE - SEE ELEVATIONS
KNEE WALL TO BE WRAPPED IN SPECIFIED LAMINATE - SEE ELEVATION
INSIDE WALL MOUNT SUPPORT BRACKETS AS NEEDED
6"
FRL-1 ON 1/2" AC PLYWOOD ALL SIDES OF COLUMN
FRY REGLET MILLWORK CHANNEL WITH RETURN KEYS, INSTALLED HORIZONTALLY ONLY, HORIZONTAL REVEALS ON ALL SIDES OF COLUMN ARE TO ALIGN WITH EXISTING REVEALS ON ADJACENT WALLS
4" MILLWORK REVEAL BASE WITH RETURN KEY
PANELS TO BE MOUNTED USING Z-CLIP SYSTEM
MILLWORK CHANNEL "L" ANGLE WITH RETURN KEY - TO BE INSTALLED TIGHT TO THE CEILING
EXISTING STRUCTURAL COLUMN
3-5/8" METAL STUDS ALL SIDES
FRL-1 ON 1/2" AC PLYWOOD ALL SIDES OF COLUMN
3/4" PLYWOOD ALL SIDES
STUDS TO EXTEND 6" ABOVE CEILING
SEE RCP FOR CEILING INFORMATION
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 11
:26:
22 A
M
A6.0
INTE
RIO
R EL
EVAT
ION
S &
DETA
ILS
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
127
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
A6.0 3/8" = 1'-0"
5 INTERIOR ELEVATIONCOUNTERTOP ELEVATION
A6.0 3/8" = 1'-0"
1 INTERIOR ELEVATIONMONITOR ELEVATION A A6.0 3/8" = 1'-0"
2 INTERIOR ELEVATIONMONITOR ELEVATION B A6.0 3/8" = 1'-0"
3 INTERIOR ELEVATIONDEMOUNTABLE WALL ELEVATION
A6.0 1 1/2" = 1'-0"
11 DETAILCOUNTERTOP DETAIL
A6.0 1 1/2" = 1'-0"
15 DETAILROLLER SHADE - CYBER LAB
A6.0 1 1/2" = 1'-0"
10 CEILING DETAILBULKHEAD AT DEMOUNTABLE WALL
A6.0 1 1/2" = 1'-0"
16 DETAIL
A6.0 3/8" = 1'-0"
8 INTERIOR ELEVATION50" MONITOR @ COLUMN - CYBER LAB
A6.0 3/4" = 1'-0"
13 DETAILCOLUMNS - 3D VIEW
A6.0 3/8" = 1'-0"
7 INTERIOR ELEVATIONEXTERIOR WALL
A6.0 1 1/2" = 1'-0"
12 DETAILCEILING TV MOUNT - CYBER LAB
A6.0 1 1/2" = 1'-0"
9 DETAILCOLUMN WRAP DETAIL A
REVISIONS
A6.0 3/8" = 1'-0"
6 INTERIOR ELEVATIONA6.0 3/8" = 1'-0"
4 TECH COUNTER
A6.0 1" = 1'-0"
14 DETAILCOLUMN WRAP DETAIL B
FINISH LEGENDFLOORKEY
CPT-1
TYPE
CARPET TILE
DETAIL DESCRIPTION
PNT-1 PAINT
PNT-4 PAINT
MANUFACTURER: Sherwin WilliamsCOLOR: SW 7015 Repose GrayLOCATIONS: Field Paint
PNT-3 PAINT
MANUFACTURER: Sherwin WilliamsCOLOR: SW 6797 Jay BlueLOCATION: Accent Wall
MANUFACTURER: Sherwin WilliamsCOLOR: SW 7007 Ceiling Bright WhiteFINISH: FlatLOCATION: Gyp. Bulkheads unless specified otherwise
BASE
CPT-2
MANUFACTURER: InterfaceSTYLE NAME: BitrateCOLOR: 106305 Dark BlueSIZE: 25cm x 1mINSTALLATION: See Finish floor Plan, 1/A7.0
CARPET TILE
KEY TYPE DETAIL DESCRIPTION
MANUFACTURER: InterfaceSTYLE NAME: UploadCOLOR: 106297 Light BlueSIZE: 25cm x 1mINSTALLATION: See Finish floor Plan, 1/A7.0
CPT-3
HTB-1 HARD TILE MANUFACTURER: CrossvilleSTYLE NAME: Cross ColorsCOLOR: Onyx A880 Cove base standard + Cove base corner - rightSIZE: 6" x 8"
HTF-1 HARD TILE PRODUCT EQUAL TO:MANUFACTURER: Crossville STYLE NAME: Cross ColorsCOLOR: Onyx A880 - Cross-Slate (CS)SIZE: 12x12INSTALLATION: At all Columns noted to recieve demo and at transition to carpet in Cyber Lounge
RB-1 RUBBER BASE PRODUCT EQUAL TO:MANUFACTURER: Johnsonite PRODUCT: Millwork - Reveal MW-XX-F6COLOR: 20 CharcoalSIZE: 6"
MILLWORKKEY TYPE DETAIL DESCRIPTION
PL-1 PLASTIC LAMINATE MANUFACTURER: FormicaCOLOR: Storm HexLOCATION: Tech counter - See Interion Elevations
TRIM & TRANSITIONSNUMBER TYPE DETAIL DESCRIPTION
TR-1 TRANSITION SCHLUTER SYSTEMS, RENO-TK PROFILE IN BRUSHED STAINLESS (TYP. BETWEEN CARPET & HARD TILE)
TR-2 TRANSITION JOHNSONITE SLT-XX-L, IN COLOR: SUBMIT FULL RANGE (TYP WHERE CARPET MEETS FINISH CONCRETE)
THESE TRANSITIONS ARE TYPICAL & TO BE INSTALLED AT ALL LOCATIONS WHERE THESE CONDITIONS OCCUR. SOME ARE SPECIFICALLY INDICATED FOR CLARITY.
WALK-OFF CARPET TILE
PRODUCT EQUAL TO:MANUFACTURER: Tandus CentivaSTYLE NAME: Assertive Stria 04839COLOR: ChromiumSIZE: 24" x 24"INSTALLATION: AshlarLOCATION: Entry and Stairs
SC-1 SEALED CONCRETE PRODUCT EQUAL TO:MANUFACTURER: H&CSTYLE NAME: Colortop SealerCOLOR: SW 7066 Gray MattersFINISH: 5% Grit Extra FineINSTALLATION: Per manufactures instructions
PNT-2 PAINT MANUFACTURER: Sherwin WilliamsCOLOR: SW 7068 Grizzle GrayLOCATION: Corridor Trim, Door & Window Frames
CPT-4 ALTERNATE BROADLOOMCARPET
MANUFACTURER: ManningtonSTYLE NAME: Glitch Art - Cross TalkCOLOR: Plasma Effect (custom) CUSTOM NUMBER: M41796-002A-10LOCATION: Case rooms with auditorium style seatingRep Contact: Nels Howalt / 1-615-618-3303
WALLKEY TYPE DETAIL DESCRIPTION
MISC.NUMBER TYPE DETAIL DESCRIPTION
PL-2 PLASTIC LAMINATE MANUFACTURER: WilsonartCOLOR: Fawn Cypress 8208K-16LOCATION: Tech counter - See Interion Elevations
FRL-1 FIBER REINFORCED LAMINATE
MANUFACTURER: PanolamPRODUCT: FRL Wall Protection PanelsCOLOR: HP565SD Storm Gray - True FRL INSTALLATION: To be applied to AC plywood with recommended adhesive- See Detail 9/A6.0 LOCATION: At Columns to remain - See Detail 9/A6.0CONTACT REP FOR SPECIFIC COLORATION: Beth Heins - C:404-548-7720 [email protected]
WC-1 WINDOW COVERING
(MANUAL - BASE BID)
MANUFACTURER: LutronSTYLE: Manual - Single Shade - with FaciaMOUNTING: Outside Ceiling mountedFABRIC: T-Screen w/ Kool Black(White side to face Exterior)COLOR: White / CharcoalMODEL: TS0235K-3SAMPLE: WSF-TS0235K-3
WDF & WD2L
STAINED WOODDOORS
MANUFACTURER: ASSA ABLOYSTYLE: Graham Flush Wood DoorsSPECIES: Plain Sliced White Birch STAIN: 550-1014
FO FLOOR OUTLET SEE ELECTRICAL DRAWINGS FOR SPECIFICATION. LOCATIONS PER ARCHITECTURAL DRAWINGS.
WC-2 WINDOW COVERING
(POWEREDALTERNATE)
MANUFACTURER: LutronSTYLE: Roller 64 - Single Shade - with FaciaMOUNTING: Outside Ceiling mountedFABRIC: T-Screen w/ Kool Black(White side to face Exterior)COLOR: White / CharcoalMODEL: TS0235K-3SAMPLE: WSF-TS0235K-3
(Alternate in Cybersecurity Lab 219 ONLY) CYBERSECURITY LAB
219
CYBER LOUNGE218
LAB SUPPORT217
EXIST. CORRIDOR211
EXIST. CLASSROOM220
EXIST. CLASSROOM232C
STAIRS219
FO
FO FO
FOFO
EXISTING FLOOR / BASE TILE TO REMAIN
ALIGN TRANSITION WITH CORNERLINE OF EXISTING TILE
FLOORING TO BE REMOVED
FO FO FO
PNT-1,2,4RB-1
CPT-1,CPT-2
CPT-1
CPT-1
CPT-1
CPT-2
CPT-2
PNT-1,4RB-1
CPT-1,CPT-2
PNT-1RB-1SC-1
PNT-4
PNT-
4
PNT-
4
PNT-4
PNT-2WINDOW FRAME & SILLS
PNT-2WINDOW FRAME & SILLS
PNT-2WINDOW FRAME & SILLS
HTF-1
PNT-4A6.0
4
PNT-
4
PNT-4
WC-
1
WC-
1: B
ASE
BID
WC-
2: A
LTER
NATE
WC-1: BASE BIDWC-2: ALTERNATE
WC-1: BASE BID
WC-2: ALTERNATE
WC-
1: BA
SE B
IDW
C-2:
ALTE
RNAT
E
A) FLOORING NOTES:1. ARRANGE A PRE-CONSTRUCTION MEETING TO CONFIRM CARPET BORDERS AND TILE PATTERNS.2. ALL PORCELAIN TILE GROUT JOINTS SHOULD BE 1/8", UNLESS OTHERWISE NOTED.3. FINISHED GROUT WILL NOT BE ACCEPTED UNTIL A SAMPLE MOCKUP IS SUBMITTED FOR APPROVAL.4. FLOORING TRANSITIONS AT DOORWAYS SHOULD ALWAYS BE ALIGNED SO THAT THEY ARE NOT VISIBLE WHEN DOORS ARE SHUT.5. TILE AND CARPET HATCHING ARE SHOWN IN LEGEND TO THE EXTENT USED IN PATTERNS AND BORDERS. UNHATCHED ROOMS OR SPACES ARE EITHER
SINGLE MATERIALS OR ARE IN THE REMAINING FIELD MATERIAL NOT EXPLICITLY HATCHED FOR CLARITY.6. ALL EXPOSED CONCRETE FLOORS SHALL BE PROPERLY REPAIRED AND SEALED W/ H&C HIGH PERFORMANCE INDUSTRIAL CLEAR COAT, W/ SHARK GRIP
ADDITIVE (OR APP. EQ.), & INSTALLED PER MANUFACTURER'S INSTRUCTIONS.7. REFER TO ALL A7.0 SERIES SHEETS FOR EXACT FLOORING TRANSITION LOCATIONS & PATTERN INFO.8. WHERE PORCELAIN WALL BASE IS USED, GROUT SHOULD BE OMITTED ALONG THE TOP EDGE, IN LIEU OF CAULK, TO ENSURE NEAT INSTALLATION OF
WALL FINISHES.9. ALL CARPET TILE SHOULD BE CENTERED IN ROOM, NO LESS THAN 1/2 OF TILE SHOULD ALIGN ALL EDGES OF THE ROOM.
B) TRIM/MILLWORK/CASEWORK/RUBBER TRIM NOTES:1. ALL DOORS SCHEDULED TO BE PAINTED, WOOD & METAL TRIM ARE TO BE SEMI-GLOSS FINISH, UNLESS OTHERWISE NOTED.2. REFER TO INTERIOR ELEVATIONS & DOOR SCHEDULE FOR INTERIOR DOOR FINISH INFO.3. SEE FINISH LEGEND AND INTERIOR ELEVATIONS FOR CABINETRY FINISHES.4. CABINET & CASEWORK DOORS/DRAWERS ARE FULL-OVERLAY STYLE, UNLESS OTHERWISE NOTED.5. ANY OPEN/EXPOSED SHELVING IN CABINETRY IS TO BE FINISHED TO MATCH ADJACENT DOOR/DRAWER FINISHES, INSTEAD OF WHITE MELAMINE. WHITE
MELAMINE SHOULD NOT BE VISIBLE WHEN DOORS AND DRAWERS ARE CLOSED.6. ALL UPPER CABINETS TO HAVE TWO ADJUSTABLE SHELVES PER UNIT, ALL LOWER CABINETS TO HAVE ONE ADJUSTABLE SHELF PER UNIT, UNLESS
OTHERWISE NOTED.7. ALL EDGES OF DOORS AND DRAWERS OF CASEWORK ARE TO HAVE MINIMUM 3MM PVC EDGEBANDING APPLIED. SUBMIT FULL RANGE OF CANPLAST (OR
APPROVED EQUAL) COLORS FOR APPROVAL. (DOES NOT APPLY TO MILLWORK.)8. ALL HINGES, UNLESS OTHERWISE NOTED, ARE TO BE CONCEALED.9. COUNTERTOPS ARE TO HAVE MINIMUM 3/4" OVERHANG, ON ALL SIDES, TYP.10. RAKKS BRACKETS: SPACING, QUANTITY, AND INSTALLATION METHODS TO BE COORDINATED BY GENERAL CONTRACTOR, BASED ON MANUFACTURER'S
INSTRUCTIONS.
C) WALL FINISH NOTES:1. ALL PAINTED GYP WALLS ARE TO BE EGGSHELL FINISH, UNLESS OTHERWISE NOTED.2. ALL TILED WALLS AND WET-WALLS ARE TO BE MOISTURE-RESISTANT GYP. BOARD UNLESS OTHERWISE NOTED.3. PROVIDE 8.5"X11" RETAINER FOR ALL PAINTS SPECIFIED BEFORE APPLYING PAINT SAMPLES ON JOB SITE. BENCHMARK SAMPLES WILL BE REVIEWED ON
SITE IN CONDITIONS ACCORDING TO SPECIFICATIONS PRIOR TO FINISH PAINTING.4. WHERE CEILING IS EXPOSED & PAINTED, CONTRACTOR IS TO STRIKE LINE AT POINT OF LOWEST STRUCTURAL, ELECTRICAL, HVAC, OR SPRINKLER
COMPONENT TO TRANSITION FROM WALL TO CEILING PAINT.5. ALL VINYL WALLCOVERING IS TO BE MICRO-PERFORATED.
D) MISC./GENERAL NOTES:1. ALL PAINTED GYP CEILINGS & EXPOSED CEILINGS ARE TO BE PNT-XXX FLAT FINISH, UNLESS OTHERWISE NOTED.2. PROVIDE DELIVERY SCHEDULE OF ALL FINISH MATERIALS 10 DAYS FOLLOWING BID DATE.3. PROVIDE MEMO SAMPLES OF ALL SPECIFIED INTERIOR FINISHES ACCORDING TO SPECS. 4. ALL EXTERIOR FINISHES ARE SPECIFIED ELSEWHERE. VERIFY ALL EXTERIOR FINISHES WITH ARCHITECT BEFORE PROCEEDING.5. GWB LOCATED ADJACENT TO WALLS AT COFFER DETAILS SHALL BE PAINTED TO MATCH WALL COLORS UNLESS OTHERWISE NOTED.6. CONTRACTOR TO VERIFY AND COORDINATE WITH ARCHITECT ALL FINISHES INCLUDING WALLS, FLOORS, AND CEILINGS.
SCHEDULED CARPET
TR-1, EQUAL TO SCHLUTER SYSTEMS, RENO-TK PROFILE IN BRUSHED STAINLESS STEEL
CONCRETE SLAB
SCHEDULED HARD TILE FLOOR
SCHEDULED CARPET
TR-2, EQUAL TO TARKETT1/8" MATERIAL TO SUBFLOOR TRANSITION STRIP OR EQUAL; FINISH: SUBMITFULL RANGE TO BE SELECTEDBY DESIGNER.
CONCRETE SLAB WITH SCHEDULED FINISH
FINISH SCHEDULE
Room No Room Name Floor Finish Wall Finish Base Finish Comments
115 EXIST. CORRIDOR HTF-1 PNT-1,2 EXISTING TO REMAIN Flooring to be replaced around column only125 EXISTING CORRIDOR HTF-1 PNT-1,2 EXISTING TO REMAIN Flooring to be replaced around column only146 EXISTING CORRIDOR HTF-1 PNT-1,2 EXISTING TO REMAIN Flooring to be replaced around column only146A AIRLOCK CPT-3 PNT-2 RB-1207 EXISTING OFFICE HTF-1 PNT-1,2 EXISTING TO REMAIN Flooring to be replaced around column only211 EXIST. CORRIDOR HTF-1 PNT-1,2 EXISTING TO REMAIN Flooring to be replaced around column only217 LAB SUPPORT SC-1 PNT-1 RB-1218 CYBER LOUNGE CPT-1,CPT-2 PNT-1,2,4 RB-1219 CYBERSECURITY LAB CPT-1,CPT-2 PNT-1,4 RB-1231 EXISTING CORRIDOR HTF-1 PNT-1,2 EXISTING TO REMAIN Flooring to be replaced around column only233 AIRLOCK CPT-3 PNT-1243 CLASSROOM NONE PNT-2 WINDOW SILLS NONE INTERIOR SIDE OF DOOR FRAME AND
WINDOW FRAMES/ SILLS TO RECEIVE PNT-2
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
3/9/
2020
8:0
0:11
AM
A7.0
PART
IAL
SEC
ON
D F
LOO
R FI
NIS
H P
LAN
, IN
TERI
OR
FIN
ISH
LEG
END
AN
D S
CH
EDU
LE
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
128
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
A7.0 1/4" = 1'-0"
1 PARTIAL FINISH PLAN - SECOND FLOOR
GENERAL FINISH NOTES
0' 2' 4 8' 16'
KEY PLAN
A7.0 3" = 1'-0"
2 DETAILCARPET TO HARD TILE
FINISH SCHEDULE - ALTERNATE
Room No Room NameFloorFinish Wall Finish Base Finish Comments
116 EXISTING TEAM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2117 EXISTING TEAM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2119 EXISTING TEAM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2149 CONFERENCE CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2150 EXISTING STUDY RESOURCE CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2205 EXIST. CLASSROOM CPT-1 MATCH EXSTING; TOUCH UP AS NEEDED MATCH EXISTING; TOUCH UP AS NEEDED206 COMPUTER CLASSROOM CPT-1 MATCH EXSTING; TOUCH UP AS NEEDED MATCH EXISTING; TOUCH UP AS NEEDED209 EXIST. CLASSROOM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2220 EXIST. CLASSROOM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2222 EXIST. CLASSROOM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2224 EXIST. CLASSROOM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2232C EXIST. CLASSROOM CPT-1 PNT-1 OVER EXISTING VINYL WALLCOVERING PNT-2 INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2243 CLASSROOM NONE PNT-2 WINDOW SILLS NONE INTERIOR SIDE OF DOOR FRAME AND WINDOW FRAMES/ SILLS TO RECEIVE PNT-2
REVISIONS
1 Addendum #1 MARCH 9, 2020
A7.0 3" = 1'-0"
3 DETAILCARPET TO SEALED CONCRETE
1
1
1
1
1
1
C C
B B
A A
8
8
9
9
7
7
EXIST.CLASSROOM
232CEXIST. CLASSROOM
220
STAIRS219
CEILING MOUNTED MONITORS
217
1906 SF
CYBERSECURITYLAB219
LABSUPPORT
102 SF
LABSUPPORT
217
219B
219A
MONITOR
60 SEATS
OPEN SHELF STORAGE
657 SF
CYBER LOUNGE218
MONITORS
8'-0"
10'-5" 13'-3"
DEMOUNTABLE WALL WITH FULL HEIGHT GLASS AND DIGITAL WINDOW FILM (TO BE INCLUDED IN FURNITURE PACKAGE)
A6.0
5
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
CEILING MOUNTED MONITOR
FLOOR BOX(ES)
FLOOR BOX FLOOR BOX
FLOOR BOX(ES)
FLOOR BOX
WALL MOUNTED MONITOR
WALL MOUNTED MONITOR
FLOOR BOX
OPEN SHELF STORAGE
A6.07
A6.0
8
MONITORSMONITORS
MONITORSMONITORS
MONITOR
MONITOR
FURNITURE SHOWN TO BE INCLUDED IN FURNITURE PACKAGE
6
A6.0
4
R R
Not For
s
n
t ur
Co
P
tc
in
Y
o
IE
IL M AN
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:16:
55 A
M
A7.1
CYB
ERSE
CU
RITY
LAB
-SE
CO
ND
FLO
OR
FURN
ITU
RE P
LAN
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S30
1 SP
ARKM
AN D
RIVE
, HU
NTS
VILL
E, A
L 35
899
LWF
02-25-2020
FPA #07519
RS
100 % CDs
129
NORTH
1/4" = 1'-0"
CYBERSECURITY LAB - FURNITURE PLAN
0' 2' 4 8' 16'
KEY PLAN
REVISIONS
DOOR & FRAME GENERAL NOTES
1. AT DOORS AND OPENINGS IDENTIFIED ON THE FLOOR PLAN WITH AN "EX", THE EXISTING DOOR, FRAME, AND HARDWARE ARE TO REMAIN. EXISTING FRAME IS TO BE PAINTED. ANY EXISTING LITE FRAMES ARE TO BE PAINTED.
2. ALL STEEL DOORS AND ALL FRAMES SHALL COMPLY WITH STEEL DOOR INSTITUTE SDI 100/ANSI A250.8 "RECOMMENDED SPECIFICATIONS FOR STANDARD STEEL DOORS AND FRAMES" LEVEL 2 HEAVY DUTY FOR INTERIOR APPLICATIONS AND LEVEL 3 EXTRA HEAVY DUTY FOR EXTERIOR APPLICATIONS.
3. DOOR LOUVERS SHALL COMPLY WITH STEEL DOOR INSTITUTE SDI 111C "RECOMMENDED LOUVER DETAILED FOR STANDARD STEEL DOORS".
4. DOOR LOUVERS SHALL BE INSERT LOUVERS UNLESS NOTED OTHERWISE AND SHALL BE INVERTED "V" BLADES. LOUVER FRAMES SHALL BE MINIMUM 20 GAUGE STEEL AND LOUVER BLADES SHALL BE MINIMUM 24 GAUGE. LOUVERS SHALL PROVIDE A MINIMUM 50% FREE AREA IN A GIVEN SIZE LOUVER.
5. ALL DOORS SHALL BE 1-3/4" THICK WITH A STANDARD 3/4" UNDERCUT.6. VISION GLASS IN ALL DOORS, VIEW WINDOWS AND SIDE LITES SHALL BE MIN 1/4"
THICK TEMPERED GLASS UNLESS NOTED OTHERWISE.7. ALL STEEL DOORS SHALL HAVE NON-BEVELED HINGE EDGE REINFORCED WITH A
CONTINUOUS OR SEGMENTED 16 GAUGE STEEL CHANNEL PROJECTION WELDED AT A MAXIMUM 5" ON CENTER.
8. ALL STEEL DOORS SHALL HAVE OVERLAPPING EDGE SEAMS, FLUSH 16 GAUGE TOP CHANNEL AND INVERTED 16 GAUGE BOTTOM CHANNEL.
9. STEEL DOOR CORES FOR NON-RATED APPLICATIONS SHALL BE MANUFACTURERS STANDARD POLYSTYRENE REINFORCED BY LAMINATING FACE SKINS TO A FOAM CORE SLAB WITH MINIMUM DENSITY OF 1 POUND PER CUBIC FOOT.
10. STEEL DOOR FACE SKINS SHALL BE MINIMUM 18 GAUGE FOR DOOR WIDTHS UP TO 36-INCHES. 6 AND 4 PANEL (ELEVATIONS E4 AND E6) DOORS AND DOOR WIDTHS GREATER THAN 36-INCHES SHALL BE MINIMUM 16 GAUGE.
11. ALL FIRE RATED DOORS AND FRAMES SHALL COMPLY WITH NFPA 80 AND/OR THE AUTHORITY HAVING JURISDICTION.
12. ALL INTERIOR DOOR FRAME PROFILES SHALL BE MINIMUM 16 GAUGE, STANDARD DOUBLE RABBET PROFILE, MULTI-USE WITH DIE-MITERED CORNER CONSTRUCTION, ADJUSTABLE BASE ANCHORS AND FACTORY APPLIED BAKED-ON RUST INHIBITING PRIMER (ANSI A250.10-1998).
DOOR, FRAME and CONFIGURATION LEGENDAL ALUMINUM STOREFRONT
DOOR ALUM ALUMINUMCS CASED OPENINGF FLUSH DOORFG FULL GLASS DOORGP GLASS PARTITIONHM HOLLOW METALHO HOLD OPENINSUL INSULATEDMTL METAL/STEEL
DOOR & FRAME KEY NOTES
A. EXISTING DOOR AND FRAME: PAINT EXISTING HM FRAME ON RENOVATION SIDE(S) OF OPENING. EXISTING DOOR, HARDWARE AND FINISH TO REMAIN. ENSURE HARDWARE IS IN GOOD OPERATIONAL CONDITION, AND REPAIR IF NECESSARY.
B. IF CLASSROOM ALTERNATE APPROVED AND IS TO PROCEED; EXISTING DOOR AND FRAME: PAINT EXISTING HM FRAME ON BOTH SIDE(S) OF OPENING. EXISTING DOOR, HARDWARE AND FINISH TO REMAIN. ENSURE HARDWARE IS IN GOOD OPERATIONAL CONDITION, AND REPAIR IF NECESSARY.
DOOR SIGNAGE NOTES
GENERAL SIGNAGE NOTES:• GC TO COORDINATE ALL SIGNAGE REQUIRED BY APPLICABLE BUILDING CODES
PRIOR TO FINAL INSPECTIONS.• PROVIDE SIGNS BY INPRO OR PRE- APPROVED EQUAL.• TACTILE CHARACTERS SHALL BE RAISED THE REQUIRED 1/32" FROM THE SIGN
FACE. SEE DOOR SCHEDULES FOR OTHER SPECIFIC LOCATIONS TO RECEIVE TEXT.• LETTERING AND BRAILLE SHALL CONFORM TO ADA/ANSI REQUIREMENTS WITH
RESPECT TO, BUT NOT LIMITED TO TYPE FACES, PROPORTION, HEIGHT, SPACING, ANY OTHER CONFLICTS (SUCH AS FIT OF REQUESTED LETTERING WITHIN SIGN LIMITS OR ANY OTHER PROVISION.)
• ALL SIGNS ARE TO BE SECURED TO WALL ON LATCH SIDE OF DOOR WITH SCREWS OR TAMPER-PROOF FASTENERS. MOUNT CENTER OF SIGN PER ADA GUIDELINES.
• SUBMIT SIGNAGE MESSAGE, FINISHES AND GRAPHICS TO ARCHITECT FOR APPROVAL, CLIENT TO APPROVE PRIOR TO FABRICATION
PREFIN PREFINISHEDSF STOREFRONTSS STAINLESS STEELWDF WOOD FLUSHWD2L WOOD TWO LITESG SINGLEAA PAIR, BOTH ACTIVEAI PAIR, ACTIVE, INACTIVEDE DOUBLE EGRESSSD SINGLE, DOUBLE ACTING
WDF
SCHE
DULE
D HE
IGHT
WIDTHSCHEDULED
BOTT
OF
GLA S
S12
" M
IN T
O
TO GLASS6" MIN
TO G
LASS
6" M
IN
WIDTHSCHEDULED
SCHE
DULE
D HE
IGHT
WD2L
3'-4"
6" M
IN 1/4" CLEAR TEMP. GLASS
METAL LITE FRAMEPAINTED PNT-2
STAIN FINISH: ASSA ABLOY, GRAHAM: PLAIN SLICED WHITE BIRCH - FINISH: 550-1014
1/4" CLEAR TEMP. GLASS F1
SCHE
DULE
D HE
IGHT
2"
2"WIDTH
SCHEDULED 2"
FRAMEPAINTED PNT-2
1'
2'
3'
4'
5'
6'
7'
48" MIN.(LOWEST TACTILE CHARACTERBASELINE NOT PERMITTEDBELOW BASELINE ZONE)
(HIGHEST TACTILE CHARACTER BASELINE NOTPERMITTED ABOVE BASELINEZONE) 60" MAX
TACTILE CHARACTERBASELINE ZONE
1'-6"
18"x18" CLEARFLOOR AREACENTERED ONTACTILE SIGN
TACTILE SIGNS ATSINGLE DOORS
0'-9"
POSITION SIGN ON LATCHSIDE OF DOOR ORNEAREST ADJACENT WALL,AT 9 INCH MINIMUMDISTANCE FROM THE CENTER OF THE RAISEDCHARACTERS ON THE SIGN
LATCH SIDE OF THE DOOR
TACTILE SIGNS ATDOUBLE DOORS
0'-9"
INACTIVE DOOR LEAF ACTIVE DOOR LEAF
0'-9"
1'-6"
18"x18" CLEARFLOOR AREACENTERED ONTACTILE SIGN
POSITION SIGN ON THEINACTIVE DOOR LEAF. IFTWO ACTIVE DOOR LEAFS, SIGN TO BE INSTALLED TORIGHT OF RIGHT HAND DOOR. IF SPACE IS NOT AVAILABLE, THEN INSTALLON NEAREST ADJACENTWALL.
45°
MINIMUM 18"x18" CLEARFLOOR AREA, CENTERED ON TACTILE CHARACTERS OF SIGN
MINIMUM 18"x18" CLEARFLOOR AREA, CENTERED ON TACTILE CHARACTERS OF SIGN
SIGNS CONTAINING TACTILE CHARACTERSSHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18"x18" MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF THE DOOR SWING BETWEEN CLOSE AND 45DEGREES OPEN
45°
6" X 9"TYPE 1
6" X 9"TYPE 2
6" X 8"TYPE 3
5" IN
CH
1 1/
2" IN
CH
8" X 8"TYPE 5
CLASSROOM
12" X 18"TYPE 6
(PROVIDE 1 AT EACH LANDINGWITHIN STAIR)
INTERIOR SIGNAGE:
*BASIS OF DESIGN IS: INPRO SIGNAGE - ZURICH COLLECTION 8-1/2"X11" LANDSCAPE INSERT. COORDINATE FINISHES, FINAL DIMENSIONS, GRAPHICS AND WORDING WITH DESIGNER.
1. SIGN MATERIAL SHALL BE APPROX. 1/8" THICK W/ CONTRASTING CORE COLOR2. TACTILE CHARACTERS SHALLS BE RAISED THE REQUIRED 1/32" FROM THE SIGN FACE. SEE DOOR SCHEDULES FOR OTHER SPECIFIC LOCATIONS TO RECEIVE TEXT3. SECURE SIGNS TO WALL ON LATCH SIDE OF DOOR W/ SCREWS OR TAMPER-PROOF FASTENERS. MOUNT CENTER OF SIGN TO 60" A.F.F.5. COLOR:• INSET BOARDER: SUBMIT FULL RANGE OF COLORS/FINISHES
FOR DESIGNERS REVIEW AND SELECTION• BACKPLATE: SUBMIT FULL RANGE OF COLORS/FINISHES FOR
DESIGNERS REVIEW AND SELECTION• TEXT: SUBMIT FULL RANGE OF COLORS/FINISHES FOR
DESIGNERS REVIEW AND SELECTION6. STANDARD OF DESIGN IS CURRENTLY INSTALLED IN THE UAH I2C AND SSB. CONTACT DESIGNER FOR MORE INFORMATION.
SIGNAGE LEGEND
8" X 8"TYPE 4OFFICE
8" X 5"TYPE 7
JANITOR106
GRADE 2 BRAILLE
INTERIOR SIGNAGE:
*BASIS OF DESIGN IS: INPRO SIGNAGE - ZURICH COLLECTION 8-1/2"X11" LANDSCAPE INSERT. COORDINATE FINISHES, FINAL DIMENSIONS, GRAPHICS AND WORDING WITH DESIGNER.
1. SIGN MATERIAL SHALL BE APPROX. 1/8" THICK W/ CONTRASTING CORE COLOR2. TACTILE CHARACTERS SHALLS BE RAISED THE REQUIRED 1/32" FROM THE SIGN FACE. SEE DOOR SCHEDULES FOR OTHER SPECIFIC LOCATIONS TO RECEIVE TEXT3. SECURE SIGNS TO WALL ON LATCH SIDE OF DOOR W/ SCREWS OR TAMPER-PROOF FASTENERS. MOUNT CENTER OF SIGN TO 60" A.F.F.5. COLOR:• INSET BOARDER: SUBMIT FULL RANGE OF COLORS/FINISHES
FOR DESIGNERS REVIEW AND SELECTION• BACKPLATE: SUBMIT FULL RANGE OF COLORS/FINISHES FOR
DESIGNERS REVIEW AND SELECTION• TEXT: SUBMIT FULL RANGE OF COLORS/FINISHES FOR
DESIGNERS REVIEW AND SELECTION6. STANDARD OF DESIGN IS CURRENTLY INSTALLED IN THE UAH I2C AND SSB. CONTACT DESIGNER FOR MORE INFORMATION.
6" X 9"
BASE BID SIGNAGE SCHEDULEQTY TYPE MESSAGE
ALTERNATE SIGNAGE SCHEDULE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
(SECOND FLOOR ONLY) (FIRST FLOOR ONLY)
MESSAGE
WOMENWOMEN'S RESTROOM
MENMEN'S RESTROOM
-
OFFICES/ CONFERENCE ROOMS/ WORKROOMS
NOT USED
TBD IN SUBMITTAL
CLASSROOMS/ CASE ROOMS/TEAM ROOMS/ LABS/ RESOURCE/ STAIRS
TBD IN SUBMITTAL
QTY TYPE MESSAGE
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
MESSAGE
WOMENWOMEN'S RESTROOM
MENMEN'S RESTROOM
-NOT USED
TBD IN SUBMITTAL
TBD IN SUBMITTAL
TYPE 7 JANITOR/ MECHANICAL/COPY ROOMS/ STORAGE/UTILITY/ PBX/ ELEVATORS/ SUPPORT
TYPE 7 JANITOR/ MECHANICAL/COPY ROOMS/ STORAGE/UTILITY/ MAIL ROOM/ PBX/ ELEVATORS/ AV
(1)
(1)
(8)
(13)
(14)
(2)
TBD IN SUBMITTAL TBD IN SUBMITTAL
(1)
(1)
(22)
(14)
(12)
(2)STAIRWELLS TBD IN SUBMITTAL TBD IN SUBMITTALSTAIRWELLS
OFFICES/ CONFERENCE ROOMS/ WORKROOMS
- -
CLASSROOMS/ CASE ROOMS/TEAM ROOMS/ LABS/ RESOURCE/ STAIRS
** NOTES: - ALL SIGNAGE QUATITIES ARE TO BE VERIFIED IN FIELD PRIOR TO SUBMITTAL.- MESSAGE SCHEDULE TO BE INCLUDED IN SUBMITTAL - REFER TO EXISTING ROOM NAMES FOR SUBMITTAL - FINAL TEXT AND ROOM NUMBERS TO BE APPROVED BY OWNER.
** NOTES: - ALL SIGNAGE QUATITIES ARE TO BE VERIFIED IN FIELD PRIOR TO SUBMITTAL.- MESSAGE SCHEDULE TO BE INCLUDED IN SUBMITTAL - REFER TO EXISTING ROOM NAMES FOR SUBMITTAL - FINAL TEXT AND ROOM NUMBERS TO BE APPROVED BY OWNER.
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
3/9/
2020
8:0
0:21
AM
A8.0
DO
OR
SCH
EDU
LE, D
OO
R AN
D F
RAM
E DE
TAIL
S, A
ND
INTE
RIO
R DE
TAIL
S
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LF
02-25-2020
FPA #07519
RKS
100 % CDs
1210
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
DOOR SCHEDULE
Room Name Door #DOOR FRAME DOOR & FRAME
W H T Elev Glazing Finish Type Finish Fire Rating
LAB SUPPORT 217 3'-0" 7'-0" 0'-1 3/4" WDF - STAINED A PAINTEDCYBERSECURITY LAB 219A 3'-0" 7'-0" 0'-1 3/4" WD2L TEMP STAINED A PAINTEDCYBERSECURITY LAB 219B 3'-0" 7'-0" 0'-1 3/4" WD2L TEMP STAINED A PAINTEDEXISTING RECEPTION 219F 3'-0" 7'-0" 0'-1 3/4" WD2LSTAIRS EX 5'-11 7/8" 6'-8" 0'-1 3/4" EX EX PNT-2 EX PAINTED
A8.0 1/4" = 1'-0"
1 DOOR TYPE ELEVATIONSONLY DOORS NOTED IN SCHEDULE ARE USED A8.0 1/4" = 1'-0"
2 DOOR FRAME TYPE ELEVATIONS
A8.0 1/2" = 1'-0"
3 TACTILE SIGN REQUIREMENTS
A8.0 3/32" = 1'-0"
4 SIGNAGE
A8.0 1/2" = 1'-0"
5 ELEVATIONCYBER LAB SIGNAGE
REVISIONS
1 Addendum #1 MARCH 9, 2020
1
1
1
APC-1 : 24X24 LAY-IN ACOUSTICAL CEILING & GRID SYSTEM
CEILING FINISHES:
APC-1 MANUFACTURER: ARMSTRONG STYLE: DUNE 1774COLOR: WHITEEDGE: ANGLED TEGULARSIZE: 24" X 24" X 5/8"GRID: Prelude XL 15/16" Exposed Tee. Color: WHITE
PRODUCT EQUAL TO:
EXISTING CEILING TO REMAIN
RECESSED 2X4 LED FIXTURE
LIGHTING:
RECESSED 2X2 LED FIXTURE
CEILING KEYNOTES:1. CEILING HEIGHTS ARE 9' - 9" A.F.F. UNLESS NOTED OTHERWISE.GENERAL NOTES:1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING
SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS. VERIFY IN FIELD.2. SEE ENGINEERING DRAWINGS FOR THE LOCATION OF CEILING FIXTURES, LIGHT TYPES, LIGHT FIXTURES, SWITCH LOCATIONS, AND ASSOCIATED
ITEMS. REFER TO ENGINEERING DRAWINGS FOR CIRCUITING, WIRING LAYOUT, AND ADDITIONAL INFORMATION.3. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE-CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING,
FIRE PROTECTION, ELECTRICAL, AND LIGHTING DRAWINGS.4. LIGHT FIXTURES, EXIT SIGNS, SPRINKLERS, AND OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL CEILING TILE, U.N.O.5. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND/OR CONDUIT,
PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN ARCHITECTS’ CEILING GRID LOCATION AND ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING.
6. ALL SPRINKLER HEADS TO BE CONCEALED AND FLUSH WITH THE FINISH CEILING.7. SUBMIT GRILLE, SPRINKLER, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS
PRIOR TO INSTALLATION8. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH, U.N.O.
ARCHITECT TO APPROVE LOCATION PRIOR TO INSTALLATION.9. INSTALL LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE, AND THE LIKE, TO AVOID FIXTURE SOILING OR
DAMAGE; FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW; LAMPS SHALL BE NEW AT PROJECT COMPLETION.10. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS, OR OTHER
IRREGULARITIES, AND PAINTED TO MATCH CEILING FINISH. 11. WALL SWITCH LOCATIONS SHALL BE COORDINATED WITH FURNITURE AND WALL MOUNTED EQUIPMENT LOCATIONS PRIOR TO BOX ROUGH-INS.
NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF ROUGH-INS.12. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS, AND ANY AND ALL OTHER
APPLICABLE ITEMS; INSTALL APPLICABLE NEW PLUMBING, MECHANICAL FANS, DUCTS, CONDUITS, AND OTHER RELATED AND APPURTENANT ITEMS SO AS TO NOT CONFLICT WITH LUMINARIES AND ANY AND ALL FIELD CONDITIONS.
13. REFER TO ENGINEERING DRAWINGS FOR ALL LIFE SAFETY DEVICES REQUIRED BY CODE AND ALL EMERGENCY LIGHT FIXTURES. COORDINATE LOCATION OF DEVICES WITH ALL ARCHITECTURAL DOCUMENTS PRIOR TO INSTALLATION OF BACK BOXES. REVIEW ALL ARCHITECTURAL AND ENGINEERING DOCUMENTS AND NOTIFY ARCHITECT OF ANY CONFLICTS. GENERAL CONTRACTOR TO COORDINATE AND VERIFY LOCATIONS OF EXISTING DEVICES TO REMAIN WITH ARCHITECTURAL PLANS AND NOTIFY ARCHITECT OF ANY CONFLICTS DURING THE ROUGH-IN PHASE OF PROJECT.
EXISTINGMECHANICAL
EXISTINGAUDITORIUM
EXISTINGCASE
ROOM #5
EXISTINGCASE
ROOM #4
EXISTINGATRIUMLOBBY
EXISTING CORRIDOR146
EXISTINGTRADE LAB
AIRLOCK146A
EXISTING STUDYRESOURCE
150
CONFERENCE149
WOMEN
MEN
MAIL RM
PBX
ELECT.
EXISTINGMECHANICAL
EXISTING TEAM117
EXISTING TEAM116
EXISTING TEAM118
EXISTING TEAM119
STUDYALCOVEBEHAV.
SCIENCEB.S.
CONTROLEXISTING
CORRIDOREXISTINGOFFICE
EXISTINGRECEPTION
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGOFFICE
EXISTINGRECORD
EXISTINGSTAIR
EXISTINGCASE
ROOM #1
EXISTINGCASE
ROOM #2
EXISTINGTEAM
EXIST. CORRIDOR115
EXIST. CORRIDOR115
EXIST.ELEV.
EXISTING CORRIDOR125
EXISTING CORRIDOR125 EXISTING STAIRS
256
EXISTING CORRIDOR137
EXISTING CORRIDOR137
EXIST. CONF.136
EXIST. CONF.135
EXISTING OFFICE133
EXISTING OFFICE134
EXISTING OFFICE132
EXIST. WORKROOM126
EXISTING OFFICE128
EXISTING OFFICE127
EXISTING OFFICE129
EXISTING OFFICE130
EXISTING OFFICE131
EXISTING CASEROOM #3
120
EXIST. JAN.
EXIT. ELEV.
REPAIR AND PATCH CEILING AT NEW COLUMN DETAIL
REPAIR AND PATCH CEILING WHERE COLUMN WAS REMOVED
EXISTING CEILING TO REMAIN REPAIR AND PATCH CEILING WHERE COLUMN WAS REMOVED
REPAIR AND PATCH CEILING WHERE COLUMN WAS REMOVED
repair ceilings disturbed by installation of floor boxes above
patch and repair ceiling disturbed by installation of conduit above
EXISTINGATRIUMLOBBY
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:17:
13 A
M
A9.1
FIRS
T FL
OO
R -R
EFLE
CTE
D C
EILI
NG
PLA
N
301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
LWF
02-25-2020
FPA #07519
FS
100 % CDs
1211
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
SREFLECTED CEILING PLAN NOTES
RCP LEGEND
NORTH
1/8" = 1'-0"
PARTIAL FIRST FLOOR - REFLECTED CEILING
KEY PLAN
0' 4' 8' 16' 32'
REVISIONS
COMPUTERCLASSROOM
EXIST.BALCONY
EXIST.CLASSROOM
EXIST.CORRIDOR
211
MEN
EXISTINGELEC.
WOMEN
PBX
A.F.F.APC-1
11'-4"
EX.SERVERROOM
EXISTING CORRIDOR231
EXISTINGCLOSET
EXISTINGPORCH
UTILITY
RECEPTION
STAIR
EXIST.JANITOR EXIST.
COPY RM
EXIST.ELEV.
EXISTINGMECHANICAL
EXIST.ELEV.
EXISTINGMECHANICAL
EXIST.CLASSROOM
EXIST.CLASSROOM
CLASSROOM
LABSUPPORT
EXIST.CLASSROOM
EXIST.CLASSROOM
EXIST.CLASSROOM
RECORDS
OFFICEOFFICE
OFFICE
OFFICESECRETARY
CONFERENCEROOM
STOR.
TOIL.
OFFICE
STAIRS
CORRIDOR
EXIST.CORRIDOR
207
CYBERSECURITYLAB219
CYBERLOUNGE
218
A.F.F.APC-1
9'-9"
A.F.F.APC-1
9'-9"
A.F.F.APC-1
9'-6"
CEILING MOUNTED MONITORS
DEMOUNTABLE WALL WITH FULL HEGHT GLASS (TO BE INCLUDED IN FURNITURE PACKAGE)
CEILING MOUNTED MONITOR CEILING MOUNTED
MONITOR
CEILING MOUNTED MONITORS
WALL MOUNTED MONITORS26'-4 1/4"
CEILING MOUNTED MONITOR
A.F.F.APC-1
9'-9"
10A6.0
12A6.0
15A6.0
CEILING MOUNTED ELECTRIC ROLLER SHADES AT EACH WINDOW, TYPICAL. LENGTH AS CENTERED ON EACH VERTICAL MULLION (V.I.F.)
CEILING MOUNTED ELECTRIC ROLLER SHADES AT EACH WINDOW, TYPICAL. LENGTH AS CENTERED ON EACH VERTICAL MULLION (V.I.F.)
EXIST.BALCONY
EXIST. LAB
EXIST. LAB
AIRLOCK233
CEILING MOUNTED MANUALROLLER SHADES AT EACH WINDOW, TYPICAL. LENGTH AS CENTERED ON EACH VERTICAL MULLION (V.I.F.)
A6.0
9A6.0
9
A6.0
9 sim.
APC-1 : 24X24 LAY-IN ACOUSTICAL CEILING & GRID SYSTEM
CEILING FINISHES:
APC-1 MANUFACTURER: ARMSTRONG STYLE: DUNE 1774COLOR: WHITEEDGE: ANGLED TEGULARSIZE: 24" X 24" X 5/8"GRID: Prelude XL 15/16" Exposed Tee. Color: WHITE
PRODUCT EQUAL TO:
EXISTING CEILING TO REMAIN
RECESSED 2X4 LED FIXTURE
LIGHTING:
RECESSED 2X2 LED FIXTURE
CEILING KEYNOTES:1. CEILING HEIGHTS ARE 9' - 9" A.F.F. UNLESS NOTED OTHERWISE.GENERAL NOTES:1. COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING
SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS. VERIFY IN FIELD.2. SEE ENGINEERING DRAWINGS FOR THE LOCATION OF CEILING FIXTURES, LIGHT TYPES, LIGHT FIXTURES, SWITCH LOCATIONS, AND ASSOCIATED
ITEMS. REFER TO ENGINEERING DRAWINGS FOR CIRCUITING, WIRING LAYOUT, AND ADDITIONAL INFORMATION.3. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE-CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING,
FIRE PROTECTION, ELECTRICAL, AND LIGHTING DRAWINGS.4. LIGHT FIXTURES, EXIT SIGNS, SPRINKLERS, AND OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL CEILING TILE, U.N.O.5. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, AND/OR CONDUIT,
PRIOR TO FRAMING FOR LIGHTS. ANY DISCREPANCIES BETWEEN ARCHITECTS’ CEILING GRID LOCATION AND ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING.
6. ALL SPRINKLER HEADS TO BE CONCEALED AND FLUSH WITH THE FINISH CEILING.7. SUBMIT GRILLE, SPRINKLER, THERMOSTAT, AND OTHER FIXTURE AND ELEMENT LAYOUTS TO THE ARCHITECT FOR REVIEW AT LEAST 2 WEEKS
PRIOR TO INSTALLATION8. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, AND MATCH ADJACENT CEILING FINISH, U.N.O.
ARCHITECT TO APPROVE LOCATION PRIOR TO INSTALLATION.9. INSTALL LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE, AND THE LIKE, TO AVOID FIXTURE SOILING OR
DAMAGE; FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW; LAMPS SHALL BE NEW AT PROJECT COMPLETION.10. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO VERTICAL SURFACES, FREE FROM CURVES, BREAKS, OR OTHER
IRREGULARITIES, AND PAINTED TO MATCH CEILING FINISH. 11. WALL SWITCH LOCATIONS SHALL BE COORDINATED WITH FURNITURE AND WALL MOUNTED EQUIPMENT LOCATIONS PRIOR TO BOX ROUGH-INS.
NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO INSTALLATION OF ROUGH-INS.12. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL DUCTS, STRUCTURAL ELEMENTS, AND ANY AND ALL OTHER
APPLICABLE ITEMS; INSTALL APPLICABLE NEW PLUMBING, MECHANICAL FANS, DUCTS, CONDUITS, AND OTHER RELATED AND APPURTENANT ITEMS SO AS TO NOT CONFLICT WITH LUMINARIES AND ANY AND ALL FIELD CONDITIONS.
13. REFER TO ENGINEERING DRAWINGS FOR ALL LIFE SAFETY DEVICES REQUIRED BY CODE AND ALL EMERGENCY LIGHT FIXTURES. COORDINATE LOCATION OF DEVICES WITH ALL ARCHITECTURAL DOCUMENTS PRIOR TO INSTALLATION OF BACK BOXES. REVIEW ALL ARCHITECTURAL AND ENGINEERING DOCUMENTS AND NOTIFY ARCHITECT OF ANY CONFLICTS. GENERAL CONTRACTOR TO COORDINATE AND VERIFY LOCATIONS OF EXISTING DEVICES TO REMAIN WITH ARCHITECTURAL PLANS AND NOTIFY ARCHITECT OF ANY CONFLICTS DURING THE ROUGH-IN PHASE OF PROJECT.
AMA
BALAFOETATSRE
GISTERED ARCHIT
EC
T
3196
REGISTRATIONNUMBER
RODNEY STEGER
MEMBER OF THE AMERICAN INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and licnesed for use in the titled project only. This drawing may not be
reproduced in whole or in part without written permission of FUQUA & PARTNERS ARCHITECTS, P.C.
A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/26
/202
0 10
:17:
23 A
M
A9.2
SEC
ON
D F
LOO
R -R
EFLE
CTE
D C
EILI
NG
PLA
N301
SPAR
KMAN
DRI
VE, H
UN
TSVI
LLE,
AL
3589
9
AWF/ LF
02-25-2020
FPA #07519
RKS
100 % CDs
1212
UAH
BAB
CYB
ER L
AB /
INTE
RIO
R RE
NO
VATI
ON
S
NORTH
1/8" = 1'-0"
SECOND FLOOR - REFLECTED CEILING PLAN
REFLECTED CEILING PLAN NOTES
RCP LEGEND
0' 2' 4 8' 16'
KEY PLAN
REVISIONS
J J
H H
G G
F F
E E
D D
C C
B B
A A
1
1
2
2
3
3
4
4
5
5
6
6
8
8
9
9
7
7
SPRINKLER HEADS TO BE REWORKED TO NEW CEILING IN THESE AREAS. NEW HEADS SHALL BE INSTALLED. CEILINGS TO BE INSTALLED AT THE SAME ELEVATION AS EXISTING. COORDINATE WITH ARCHITECTURAL.
CYBERSECURITY
LAB
219
CYBER LOUNGE
218
EXIST.
CLASSROOM
220
EXIST.
CLASSROOM
232C
EXIST.
CLASSROOM
222
EXIST.
CLASSROOM
224
BALCONY
230
EXISTING PORCH
208
EXIST. CORRIDOR
207
EXISTING
CORRIDOR
231
EXIST. CORRIDOR
211
LAB SUPPORT
217
GRAPHIC SCALE: 1/16" = 1'-0"
0 8' 16' 32' 48' 64'24' 40'
mdsMechanical Design Services, Inc.
100 Church St. SW, Suite 650, Huntsville, AL 35801
(256) 534-5150 [email protected]
GENERAL FIRE PROTECTION NOTES
1. THIS CONTRACTOR IS RESPONSIBLE FOR REVIEWING ALL DRAWINGS AND SPECIFICATIONS OF ALL DISCIPLINES FOR ANY AND ALL WORK THAT WILL IMPACT THIS CONTRACTOR AND WILL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE SAID WORK.
2. CONTRACTOR(S) SHALL COORDINATE PRIOR/DURING CONSTRUCTION TO ELIMINATE ANY CONFLICTS.
3. ALL WET SYSTEMS SHALL BE INSTALLED WITHIN THE WARM SIDE OF THE BUILDING INSULATION ENVELOPE OR HEATED AREA.
4. ALL SPRINKLER HEADS SHALL BE COORDINATED WITH LIGHTS, CEILING SOFFITS, SOUND BAFFLES, ARCHITECTURAL FEATURES, CEILING DEVICES, ETC. "OVER COVERAGE" SHALL BE PROVIDED TO ENSURE CEILING SYMMETRY.
5. HEADS SHALL BE PROVIDED UNDER ANY OBSTRUCTION 48" IN WIDTH OR GREATER.
6. ALL PIPING, HANGERS, ETC. SHALL NOT INTERFERE WITH MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, DEVICES, DAMPERS, ETC.
7. WIRE GUARDS ARE TO BE PROVIDED ON ALL HEADS IN ALL EXPOSED AREAS INCLUDING MECHANICAL AND ELECTRICAL ROOMS.
8. COORDINATE WITH BOTH LOCAL AND STATE AHJ AND ELECTRICAL FOR REQUIREMENTS OF ELECTRICAL EQUIPMENT SHIELDING.
THREADED ROD COUPLING AND JAMB NUT
HEAVY DUTY EXPANSION ANCHOR EQUAL TO HILTI HSLG SERIES.
CONCRETE FLOOR
WASHER & NUT
HEAVY DUTY SIDE BEAM ANGLE BRACKET FOR USE WITH WOOD, STEEL OR CONCRETE BEAMS.
NUT ON TOP AND BOTTOM.
NUT ON TOP AND BOTTOM.
CLEVIS HANGER.
BEAM CLAMP EQUAL TO PHD MFG. FIGURE 350 FOR USE WITH BEAM TOP FLANGE OR BAR JOIST.
THREADED ROD (TYPICAL).
PIPE
PIPE HANGER DETAILNOT TO SCALE
A
LA B A M
A
JO
H
NN
YN . E C
H
OL
S
JO
H
NN
YN . E C
H
OL
S
ENG I NE ER
L ICENSED
No. 30043
PROFESSIONAL
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
5/2
020 4
:46:1
6 P
M
FP1.0
FIR
E P
RO
TE
CT
ION
FLO
OR
PLA
N
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
AL.
358
99
JJP
02-25-2020
FPA #07519
JNE
COORDINATION
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
1/16" = 1'-0"
FIRE PROTECTION - 2ND FLOOR
REVISIONS
TT
T
T
T
T
GRAPHIC SCALE: 1/8" = 1'-0"
0 4' 8' 16' 24' 32'2' 6' 12'
mdsMechanical Design Services, Inc.
100 Church St. SW, Suite 650, Huntsville, AL 35801
(256) 534-5150 [email protected]
E E
D D
C C
B B
A A
8
8
9
9
7
7
54"x
14"
FD
FD
FD
FD52"x12"
44"x
14"
14"x8"
6"x10"
8"x10"
8"x
10"
12"x
12"
14"x
12"
10"x
12"
12"x
12"
6"x12"12"x12"
26"x14"
8"x
12"
14"x
12"
FD FD FD
FD
TO AC 2-1
230 CFM240 CFM
240 CFM
230 CFM
250 CFM140 CFM 190 CFM 190 CFM
240 C
FM
180 CFM
140 CFM
280 CFM
280 CFM 280 CFMDEMO SECTION OF DUCT FOR NEW FIRE DAMPER. TYPICAL FOR 3.
A
B B
A
C
C
C
AA A
AAA
AA
B
A
A A
A
EXISTING FD NOT REQUIRED, BUILDING IS NOW SPRINKLED. FIRE DAMPER TO REMAIN IN EXISTING WALL, TYPICAL FOR FIRE DAMPERS IN UNCHANGED WALLS.
D
DD
ZO
NE
D
ZO
NE
F
ZO
NE
H
ZO
NE
J
E E
D D
C C
B B
A A
8
8
9
9
7
7
EXIST. CORRIDOR
211
EXISTING
CLOSET
236
EXIST. COPY RM
225EXIST. ELEV.
239B
EXISTING
MECHANICAL
223
EXIST.
CLASSROOM
232C
LAB SUPPORT
217
EXIST.
CLASSROOM
220
EXIST.
CLASSROOM
224
EXIST.
CLASSROOM
222
STAIRS
219
CYBERSECURITY
LAB
219
CYBER LOUNGE
218
PATCH EXISTING
24X24 CD-1
125 CFM
24X24 CD-1
125 CFM
24X24 CD-1
125 CFM
24X24 CD-1
125 CFM
10"x
12"
14"x
12"
12"x
12"
24X24 CD-1
500 CFM
24X24 CD-1
500 CFM
24X24 CD-1
420 CFM
24X24 CD-1
250 CFM
24X24 CD-1
420 CFM
24X24 CD-1
420 CFM
12"x12"
14"x
12"
54"x
14"
24X24 CD-1
140 CFM
8"ø
ZONE "D"
ZONE F, J & H
8"ø8"ø
8"ø8"ø
12"ø
10"ø
EXISTING AC 2-1
22X22 CG-1
755 CFM
TYP. FOR 214X14 CG-1
400 CFM
REBALANCE AC 2-1 ZONES D,F,H, & J TO NEW FLOW RATES.
10"ø
10"ø
12"x
12"
12"x
12"
10"ø
CONNECT TO EXISTING 3" CHILLED WATER PIPING.
3/4"ø CHWS3/4"ø CHWR
1 1/4"ø HWS1 1/4"ø HWR
3"ø CHWR3"ø CHWS
52"x12"
SV
SV
IU-217
NOTE:ROUTE 3/4" CONDENSATE LINE FROM IU-217 TO FLOOR/HUB DRAIN IN EXISTING MECHANICAL ROOM 223. ROUTE IN MANNER TO NOT CAUSE A TRIP HAZARD.
24X24 CD-1
140 CFM
22X22 CG-1
INSULATED END CAP.
DUCT DAMPERS & ACTUATORSFD = FIRE DAMPER WITH ACCESS DOORM = MOTORIZED DAMPERSV = SERVICE VALVEVD = VOLUME DAMPER
PIPING SYSTEMSCHWS = CHILLED WATER SUPPLYCHWR = CHILLED WATER RETURN
SENSORS (INSIDE SENSOR ICON)T = THERMOSTAT
MECHANICAL NOTATION LEGEND MECHANICAL SYMBOL LEGEND
= NEW WORK (DUCT, EQUIPMENT, PIPE, ETC.)
= EXISTING WORK TO REMAIN
= EXISTING WORK TO BE REMOVED
= MANUAL VOLUME DAMPER
= MOTORIZED DAMPERM
T
A
= SENSOR ICON
= DEMOLITION KEY NOTE
= SUPPLY DROP / RISE
= RETURN DROP / RISE
= EXHAUST DROP / RISE
= PIPE DROP / RISE
GENERAL MECHANICAL NOTES
1. THIS CONTRACTOR IS RESPONSIBLE FOR REVIEWING ALL DRAWINGS AND SPECIFICATIONS OF ALL DISCIPLINES FOR ANY AND ALL WORK THAT WILL IMPACT THIS CONTRACTOR AND WILL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO PROVIDE SAID WORK.
2. CERTAIN AREAS WILL REQUIRE EXTENSIVE COORDINATION BETWEEN ALL TRADES. CONTRACTOR(S) SHALL COORDINATE PRIOR/DURING CONSTRUCTION TO ELIMINATE ANY CONFLICTS.
3. THE LOCATION OF ALL CEILING MOUNTED AIR DISTRIBUTION DEVICES SHALL BE COORDINATED WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND SHALL AVOID CONFLICT WITH ALL CEILING DEVICES, MOUNTED LIGHTS, PROJECTORS, ETC.
4. ALL DUCT SIZES INDICATED ON THE DRAWINGS ARE FOR THE CLEAR INSIDE DIMENSION. CONTRACTOR SHALL INCREASE DUCT SIZE IF INTERIOR DUCT INSULATION IS CALL FOR ON THE DRAWINGS. THE SAME APPLIES FOR DOUBLE WALL SPIRAL DUCT.
5. THE BOTTOM OF ALL DUCTWORK AND PIPING TO BE COORDINATED WITH ROOM FINISH SCHEDULE FOR CEILING HEIGHTS AND SHALL BE A MINIMUM OF 6" ABOVE THE CEILING GRID. ALL SERVICEABLE ITEMS SUCH AS EQUIPMENT, ACTUATORS, DAMPERS, VALVES, CONTROL DEVICES, ETC. SHALL BE LOCATED NO MORE THAN 24" ABOVE THE CEILING GRID.
6. ALL DUCTS AND PIPING INDICATED ON THE DRAWINGS ARE DIAGRAMMATIC ONLY. THEY MAY BE REQUIRED TO BE SHIFTED, OFFSET OR INSTALLED HIGH IN BETWEEN THE JOISTS AS DETERMINED BY FIELD CONDITIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL MATERIALS AND LABOR NECESSARY TO INSTALL THE PIPING AND DUCTS TO MEET THE INTENT OF THE DRAWINGS.
7. ROUND BRANCH RUN-OUTS TO AIR DISTRIBUTION DEVICES ARE TO BE ENTIRELY SHEET METAL WITH THE EXCEPTION THAT UP TO FIVE FEET OF FLEX DUCT MAY BE USED ON EACH BRANCH UNLESS OTHERWISE INDICATED. ALL FLEX DUCT SHALL BE SUPPORTED INDEPENDENT OF THE CEILING, PIPING, CONDUITS, OTHER DUCTS, ETC. AND SHALL BE SUPPORTED IN SUCH A WAY AS TO AVOID KINKING OR OBSTRUCTION OF AIR FLOW.
8. THE MECHANICAL CONTRACTOR SHALL INSTALL FIRE DAMPERS, SMOKE DAMPERS OR COMBINATION DAMPERS AT ALL FIRE RATED WALLS AND/OR SMOKE BARRIERS. REFER TO THE EXISTING ARCHITECTURAL LIFE SAFETY PLANS, IN THE OWNER'S POSSESSION, FOR THE WALL / CEILING RATINGS AND LOCATIONS.
9. CONTRACTOR SHALL NOT FABRICATE OR CONSTRUCT DUCTWORK, PIPING, ETC. FROM THE DRAWINGS PRIOR TO VERIFYING DUCT, PIPING, ETC. CAN BE INSTALLED IN THE FIELD WITH RESPECT TO FIELD CONDITIONS.
10. COORDINATE WITH ARCHITECTURAL PLANS FOR CEILING REPLACEMENT AREAS. REPLACE ANY AIR TERMINALS WITH LIKE KIND.
MECHANICAL DEMOLITION NOTES
A. REMOVE EXISTING DUCT BRANCH AND CEILING MOUNTED DIFFUSER / GRILLE BACK TO THE MAIN TRUNK INCLUDING ALL DUCT HANGERS ETC. PATCH, INSULATE & SEAL DUCTWORK AIR TIGHT. EXTEND DUCT WHERE REQUIRED AS SHOWN ON NEW DRAWING TO ATTACH TO NEW GRILLE / DIFFUSER.
B. REMOVE EXISTING FIRE DAMPER. PATCH, INSULATE & SEAL DUCTWORK AIR TIGHT.
C. REMOVE EXISTING TRANSFER DUCT INCLUDING ALL DUCT HANGERS ETC.
D. REMOVE EXISTING WALL MOUNTED PNEUMATIC THERMOSTAT. SEE SEQUENCE OF CONTROL.
A
LA B A M
A
JO
H
NN
YN . E C
H
OL
S
JO
H
NN
YN . E C
H
OL
S
ENG I NE ER
L ICENSED
No. 30043
PROFESSIONAL
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
5/2
020 4
:46:1
7 P
M
M1.0
ME
CH
AN
ICA
L F
LOO
R P
LAN
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
AL.
358
99
JJP
02-25-2020
FPA #07519
JNE
COORDINATION
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
1/8" = 1'-0"
DEMOLTION - 2ND FLOOR DUCT SYSTEMS1/8" = 1'-0"
SECOND FLOOR DUCT SYSTEMS
REVISIONS
24X24 CD-1
170 CFM
SEE MECHANICAL FLOOR PLAN FOR GRILLE CHANGES IN THIS AREA.
CEILINGS TO BE REPLACED IN THESE AREAS. REMOVE EXISTING AIR TERMINALS AND REPLACE WITH NEW. COORDINATE WITH ARCHITECTURAL.
CEILINGS TO BE REPLACED IN THESE AREAS. REMOVE EXISTING AIR TERMINALS AND REPLACE WITH NEW.COORDINATE WITH ARCHITECTURAL.
3'-0" SD-1
250 CFM
3'-0" SD-1
250 CFM
3'-0" SD-1
250 CFM
3'-0" SD-1
250 CFM
22X22 CG-1
24X24 CD-1
190 CFM
24X24 CD-1
190 CFM
24X24 CD-1
170 CFM
24X24 CD-1
170 CFM
24X24 CD-1
160 CFM
22X22 CG-1
22X22 CG-1
24X24 CD-1
140 CFM24X24 CD-1
140 CFM
mdsMechanical Design Services, Inc.
100 Church St. SW, Suite 650, Huntsville, AL 35801
(256) 534-5150 [email protected]
GRAPHIC SCALE: 1/16" = 1'-0"
0 8' 16' 32' 48' 64'24' 40'
A
LA B A M
A
JO
H
NN
YN . E C
H
OL
S
JO
H
NN
YN . E C
H
OL
S
ENG I NE ER
L ICENSED
No. 30043
PROFESSIONAL
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
5/2
020 4
:46:1
8 P
M
M2.0
ME
CH
AN
ICA
L F
LOO
R P
LAN
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
AL.
358
99
Author
02-25-2020
FPA #07519
Checker
COORDINATION
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
1/16" = 1'-0"
MECHANICAL CEILING PLAN
REVISIONS
CHILLED WATER FAN COIL UNIT WITH ELECTRIC HEAT SCHEDULE
MARK
UNIT SIZE
TOTAL AMPS
MIN. VOLT.
ACCESSORIES:
1. PROVIDE 24VAC WIRED WALL MOUNTED THERMOSTAT WITH AUTOMATIC CHANGEOVER.
2. PROVIDE 2-WAY NC VALVE AND 24V MOTORIZED ACTUATOR. PROVIDE HOSE KITS CONSISTING OF; RETURN SIDE (FULL PORT BALL VALVE, 24" STAINLESS STEEL HOSE, AUTOMATIC BALANCING VALVE WITH P/T PORTS) SUPPLY SIDE (FULL PORT BALL VALVE WITH P/T PORTS, 24" STAINLESS STEEL HOSE, Y STRAINER WITH BLOWDOWN VALVE).
3. PROVIDE CONDENSATE PUMP KIT, 115 V
NOTES:
A.
B.
SUPPLY FAN
CFM
FAN QTY
COOLING COIL
TOTAL CAPACITY, MBH
SENSIBLE CAPACITY, MBH
E.A.T. DB / WB , °F
E.W.T. DB / L.W.T., °F
ELEC. HEAT kW
BASIS OF DESIGN
MANUFACTURER
MODEL
WEIGHT, LBS.
ACCESSORIES
IU-217
GPM
WATER ΔP, PSI
FULLY INSULATE THE HOSE KITS, CONTROL VALVES AND ACCESSORIES. INSULATION SHALL BE GLUED TO THE UNIT CASING. INSULATION COVERING SERVICEABLE ITEMS SHALL BE OVER CUT AND AN ARMAFLEX UNGLUED INSERT PLACED INSIDE THE OVER CUT GLUED ARMAFLEX INSULATION.
CLOSELY COORDINATE THE UNIT LOCATION WITH OTHER TRADES.
18
600
1
17.7
80 / 67
44 / 60
2.5
4.3
197
17
20
EMI
WCP18
120
1, 2, 3
A, B
14.1
L.A.T. DB / WB , °F 59.2 / 58.6
ELECTRICAL
FAN HP
ELEC. HEAT AMPS
FAN AMPS
MCA
MOCP
VOLT / PHASE 208 / 1
13.6
3.0
13.1
0.07
0.56
NOTES
GRILLE, REGISTER AND DIFFUSER SCHEDULE
MARK
DESCRIPTION
MOUNTING
MATERIAL
FINISH
BORDER TYPE
CD-1
SQUARE PLAQUE FACE CEILING DIFFUSER
ROUND NECK
LAY-IN
ALUMINUM
ACCESSORIES:
1. TITUS HAS BEEN SPECIFIED TO ESTABLISH THE TYPE AND QUALITY OF AIR DEVICE TO BE INSTALLED. PRIOR APPROVED EQUALS WILL BE CONSIDERED. PRIOR APPROVAL REQUEST MUST BE SUBMITTED 10 DAYS PRIOR TO BID.
2.
3.
4.
5.
6.
7.
TITUS MODEL
MATCH CEILING COLOR
TYPE 3
OMNI-AA
SD-1
LAY-IN
ALUMINUM
MATCH CEILING COLOR
TYPE 2A
ML-39
CG-1
SQUARE LOUVERED FACE CEILING GRILLE, SQUARE
NECK, 35° DEFLECTION
SURFACE
ALUMINUM
MATCH CEILING COLOR
TYPE 1
350FL
MAXIMUM NC RATING SHALL NOT EXCEED 30.
AIR DEVICES THAT ARE CEILING CUT-IN TYPE SHALL BE CENTERED IN THE TILE.
CEILING MOUNTED LOUVERED RETURN / EXHAUST GRILLES SHALL BE INSTALLED WITH THE BLADES POINTED TOWARD THE CLOSEST WALL SO THAT THE BLADES FORM A VIEW BLOCK.
WALL MOUNTED RETURN / EXHAUST GRILLES SHALL BE INSTALLED WITH THE BLADES POINTING TOWARD THE FLOOR OR CEILING, WHICHEVER IS NEAREST, SO THAT THE BLADES FORM A VIEW BLOCK.
INTERNAL PORTION OF DUCT, INCLUDING INLET PLENUM BOX, ATTACHED TO SUPPLY, RETURN, EXHAUST AND TRANSFER GRILLES SHALL BE BLACKED OUT WITH A DULL FINISH, NON-TOXIC, DTM PAINT.
GRILLE TERMINATION SHALL BE FLEXMASTER FISB OR PRIOR APPROVED EQUAL UNLESS OTHERWISE SPECIFIED IN SCHEDULE ABOVE OR NOTED ON DRAWINGS. SEE DETAIL FOR DUCT TO GRILLE, REGISTER, DIFFUSER CONNECTION.
SLOT DIFFUSER, (3) 1" SLOTS, ADJUSTABLE
PATTERN CONTROLLERS
RETURN / EXHAUST AIRFLOWSUPPLY AIRFLOW
RECTANGULAR TO ROUND 45°
DUCT TAKE-OFF DETAILNOT TO SCALE
RECTANGULAR DUCT
ROUND BRANCH DUCT. SEE FLOOR PLANS FOR SIZE AND ROUTING.
45° RECTANGULAR TO ROUND DUCT TAKE-OFF EQUAL TO CROWN PRODUCTS COMPANY MODEL 3300-DS2. TAKE-OFF SHALL HAVE A CONTINUOUS ROD DAMPER WITH A 2" STAND-OFF FOR INSULATION.
NOTE:A MINIMUM 12" OF SHEET METAL DUCT SHALL BE INSTALLED ON TAKE-OFF WHERE SHORT RUNS (5' OR LESS) OF FLEX DUCT IS USED TO MAKE GRILLE / DIFFUSER CONNECTION.
BRANCH DUCT OPENING SHALL BE CUT FULL SIZE OF RECTANGULAR OPENING OF TAKE-OFF.
INSULATED FLEX DUCT
2" FG BLANKET TO COVER ENTIRE 2' X 2' TILE.
RIGID ADJUSTABLE ELBOW FORMED AT 45° AND DUCT SEALED.
STICK-ON TAP WITHOUT A DAMPER.
GRILLE, REGISTER,OR DIFFUSER
2" X 2" 24 GAUGE METAL ANGLE TO SPAN ENTIRE 2' X 2' TILE. ANGLE TO BE SECURED TO SQUARE TO ROUND ADAPTER WITH 1/4" SELF TAPPING SHEET METAL SCREWS.
ACOUSTICAL CEILING TILE
NOTE:FOIL TAPE ALL INSULATION SEAMS TO PROVIDE A VAPOR BARRIER. AIR TERMINAL SHALL BE FASTENED TO STRUCTURE ABOVE WITH METAL CABLING AND FASTENERS VIA EARTHQUAKE TABS ON AIR TERMINAL.
26 GAUGE SHEET METAL PLENUM. PLENUM SHALL BE EQUAL TO FLEXMASTER SISB. PLENUM SHALL BE SEALED WITH SPECIFIED SEALANT. PLENUM SHALL BE FULL SIZE OF GRILLE OPENING. PLENUM SHALL BE FULLY INSULATED WITH FOIL FACED WRAP. LINER WILL NOT BE ALLOWED.
2X2 A.C.T. SURFACE MOUNTED
GRILLE / REGISTER / DIFFUSER DETAILNOT TO SCALE
PROVIDE 5' OF INSULATED FLEX DUCT FOR NOISE CONTROL
RIGID ADJUSTABLE ELBOW FORMED AT 45° AND DUCT SEALED.
STICK-ON TAP WITH LOCKABLE QUADRANT DAMPER.
RETURN GRILLE
2" X 2" 24 GAUGE METAL ANGLE TO SPAN ENTIRE 2' X 2' TILE. ANGLE TO BE SECURED TO SQUARE TO ROUND ADAPTER WITH 1/4" SELF TAPPING SHEET METAL SCREWS.
ACOUSTICAL CEILING TILE
26 GAUGE SHEET METAL PLENUM. PLENUM SHALL BE EQUAL TO FLEXMASTER SISB. PLENUM SHALL BE SEALED WITH SPECIFIED SEALANT. PLENUM SHALL BE FULL SIZE OF GRILLE OPENING. PLENUM SHALL BE INTERNALLY INSULATED WITH ARMAFLEX DUCT LINER.
2X2 A.C.T. SURFACE MOUNTED
PLENUM RETURN GRILLE DETAILNOT TO SCALE
NOTE:FOIL TAPE ALL INSULATION SEAMS TO PROVIDE A VAPOR BARRIER. AIR TERMINAL SHALL BE FASTENED TO STRUCTURE ABOVE WITH METAL CABLING AND FASTENERS VIA EARTHQUAKE TABS ON AIR TERMINAL.
mdsMechanical Design Services, Inc.
100 Church St. SW, Suite 650, Huntsville, AL 35801
(256) 534-5150 [email protected]
INSULATED FLEX DUCT
2" FG BLANKET TO COVER ENTIRE 2' X 2' TILE.
RIGID ADJUSTABLE ELBOW FORMED AT 45° AND DUCT SEALED.
STICK-ON TAP WITHOUT A DAMPER.
GRILLE, REGISTER, OR DIFFUSER
NOTE:FOIL TAPE ALL INSULATION SEAMS TO PROVIDE A VAPOR BARRIER. AIR TERMINAL SHALL BE FASTENED TO STRUCTURE ABOVE WITH METAL CABLING AND FASTENERS VIA EARTHQUAKE TABS ON AIR TERMINAL.
26 GAUGE SHEET METAL PLENUM. PLENUM SHALL BE EQUAL TO FLEXMASTER SISB. PLENUM SHALL BE SEALED WITH SPECIFIED SEALANT. PLENUM SHALL BE FULL SIZE OF GRILLE OPENING. PLENUM SHALL BE FULLY INSULATED WITH FOIL FACED WRAP. LINER WILL NOT BE ALLOWED.
ACOUSTICAL CEILING LAY-IN
GRILLE / REGISTER / DIFFUSER DETAILNOT TO SCALE
SEQUENCE OF CONTOL
EXISTING AC 2-1:CYBER SECURITY LAB:THE EXISTING PNEUMATIC CONTROLS SYSTEM AND TUBING TO BE REWORKED TO SATISFY THE INTENT OF THIS SEQUENCE OF CONTROL. THE PNEUMATIC THERMOSTATS SHALL BE DEMOED WITH CARE AND REINSTALLED WHERE SHOWN ON THE DRAWINGS. THERMOSTATS NOT REQUIRED FOR REUSE SHALL BE TURNED OVER TO THE OWNER. AC 2-1 FOR ZONE DAMPERS FOR ZONES F, H & J ARE TO BE CONTROLLED BY A SINGLE PNEUMATIC THERMOSTAT (REUSED THERMOSTAT FROM DEMO). THE DAMPERS ARE TO CONTROL (OPEN / CLOSE) TOGETHER WITH THE SINGLE AIR PRESSURE CONTROL FROM THE SINGLE THERMOSTAT. CONTRACTOR TO REWORK THE PNEUMATIC TUBING AT THE AC 2-1 AND ADD NECESSARY PNEUMATIC CONTROLLERS AND PNEUMATIC RELAYS TO CONTROL THE AIR DAMPERS FROM A SINGLE PNEUMATIC THERMOSTAT FOR CYBER SECURITY LAB.
THE EXISTING AIR HANDLER OUTSIDE AIR AND SUPPLY AIR FLOW RATES ARE TO BE TESTED PRIOR TO DEMOLITION WORK BEGINS TO ESTABLISH A BASELINE. THE OUTSIDE VENTILATION AND SUPPLY AIR RATES SHALL BE RECORDED. ORIGINAL DESIGN OF AC 2-1 OUTSIDE AIR IS 1,600 CFM WITH A SUPPLY AIR RATE OF 11,800 CFM. THE RENOVATED AREA COMPRISED OF CLASSROOM SPACES WITH MORE OF AN OCCUPANCY LOAD THAN THE RENOVATED AREA.
LAB SUPPORT (SERVER ROOM):IU-217 IS TO BE CONTROLLED VIA A LOCAL THERMOSTAT. PROVIDE ANY NECESSARY RELAYS, TRANSFORMERS, CHILLED WATER ACTUATED CONTROL VALVES (2 POSITION ON/OFF CONTROL), ETC. THE WALL HARD WIRED THERMOSTAT SHALL ENABLE THE FAN AND CONTROL THE CHILLED WATER VALVE TO MAINTAIN THE SPACE COOLING SETPOINT. THE WALL HARD WIRED THERMOSTAT SHALL ENABLE THE FAN AND STAGE THE ELECTRIC HEAT TO MAINTAIN THE SPACE HEATING SET POINT.
THE CYBER SECURITY LAB AND LAB SUPPORT CONSIST OF A COMPUTER LAB AND SERVER ROOM ONLY AND DOES NOT REQUIRE GENERAL EXHAUST PER 2015 IMC TABLE 403.3.1.1.
CYBER LOUNGE SHALL BE CONTROLLED BY A REUSED PNEUMATIC THERMOSTAT. REWORK AND PROVIDE PNEUMATIC TUBING AS NEEDED FOR THE RELOCATION OF THE THERMOSTAT SHOWN ON THE NEW WORK DRAWINGS.
A
LA B A M
A
JO
H
NN
YN . E C
H
OL
S
JO
H
NN
YN . E C
H
OL
S
ENG I NE ER
L ICENSED
No. 30043
PROFESSIONAL
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
5/2
020 4
:46:1
8 P
M
M3.0
ME
CH
AN
ICA
L S
CH
ED
ULE
S
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
AL.
358
99
JJP
02-25-2020
FPA #07519
JNE
COORDINATION
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
REVISIONS
mdsMechanical Design Services, Inc.
100 Church St. SW, Suite 650, Huntsville, AL 35801
(256) 534-5150 [email protected]
GRAPHIC SCALE: 1/8" = 1'-0"
0 4' 8' 16' 24' 32'2' 6' 12'
E E
D D
C C
B B
A A
8
8
9
9
7
7
UP TO 2ND FLOOR
VALVE WITH HOSE BIBB DRAIN PORT.
EXISTING EWC TO REMAIN.
1/2"ø
3"ø
CW
3"ø3/4"ø CW
1/2"ø CW
3"ø CW
3"ø W
BELOW GRADE WASTE TO REMAIN.
EXISTING
CORRIDOR
125
EXISTING
AUDITORIUM
26
EXISTING
CORRIDOR
125EXISTING CASE
ROOM #5
124
Room
136
Room
135
EXISTING OFFICE
134
EXISTING OFFICE
132
EXISTING OFFICE
133
EXISTING OFFICE
127
EXISTING OFFICE
129
EXISTING OFFICE
130
EXISTING OFFICE
131
EXISTING
MECHANICAL
142
REMOVE EXISTING WASTE AND WATER PIPING TO THE EXTENT SHOWN AND REWORK AS SHOWN ON NEW DRAWING(S).
E E
D D
C C
B B
A A
8
8
9
9
7
7
CW & WASTE ABOVE CEILING. PIPING UP TO 3RD FLOOR TO REMAIN AND BE RECONNECTED TO NEW AS SHOWN ON NEW DRAWING(S).
EXISTING EWC. TO BE REMOVED
UP FROM 1ST FLOOR
3"ø
1/2"ø CW
3"ø C
W
3"ø W
3"ø C
W
1/2
"ø3"ø
1/2"ø C
W
3"ø
3/4"ø CW
3"ø
1/2"ø
EXISTING EWC TO REMAIN
EXISTING EWC TO REMAIN
EXISTING EWC TO BE REMOVED
EXISTING 3" VTR
REMOVE EXISTING WASTE AND WATER PIPING TO THE EXTENT SHOWN AND REWORK AS SHOWN ON NEW DRAWINGS.
A
LA B A M
A
JO
H
NN
YN . E C
H
OL
S
JO
H
NN
YN . E C
H
OL
S
ENG I NE ER
L ICENSED
No. 30043
PROFESSIONAL
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
5/2
020 4
:46:2
0 P
M
P1.0
PLU
MB
ING
FLO
OR
PLA
N -
DE
MO
LIT
ION
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
AL.
358
99
JJP
02-25-2020
FPA #07519
JNE
COORDINATION
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
1/8" = 1'-0"
DEMOLITION PLUMBING - 1ST FLOOR1/8" = 1'-0"
DEMOLITION PLUMBING - 2ND FLOORRISER DIAGRAM - DEMOLITION
REVISIONS
E E
D D
C C
B B
A A
8
8
9
9
7
7
EXISTING VALVE WITH HOSE BIBB DRAIN PORT.
EXISTING EWC TO REMAIN.
3"ø W
3"ø
CW
1/2"ø CW
UP TO 2ND FLOOR
3"ø W
ABOVE CEILING
BELOW GRADE
3"ø CW
CONNECT TO EXISTING CW & WASTE ABOVE CEILING.
E E
D D
C C
B B
A A
8
8
9
9
7
7
CYBERSECURITY
LAB
219
CYBER LOUNGE
218
EX
IST
. C
OR
RID
OR
211EXIST.
CLASSROOM
232CEXIST.
CLASSROOM
220
EXIST.
CLASSROOM
224
EXIST.
CLASSROOM
222
EXISTING
MECHANICAL
223
STAIRS
219
LAB SUPPORT
217
1/2" CW & 3" WASTE ABOVE CEILING.
CONNECT TO EXISTING CW & WASTE ABOVE 2ND FLOOR CEILING.
CW & WASTE UP FROM 1ST FLOOR. P-1
IU-217
GRAPHIC SCALE: 1/8" = 1'-0"
0 4' 8' 16' 24' 32'2' 6' 12'
mdsMechanical Design Services, Inc.
100 Church St. SW, Suite 650, Huntsville, AL 35801
(256) 534-5150 [email protected]
3"ø C
W
3"ø C
W
3"ø W
1/2"ø CW
3"ø W
3"ø W
3/4"ø CW
EXISTING EWC TO REMAIN
EXISTING EWC TO REMAIN
P-1
EXISTING VAVLE WITH HOSE BIBB DRAIN PORT.
EXISTING 3" VTR
CONNECT TO EXISTING.
CONNECT TO EXISTING.
1/2"ø CW
PLUMBING FIXTURE CONNECTION SCHEDULE
FIXTURE TAG
TYPE OF FIXTURECONNECTION SIZES
WASTE CW HW HWR
P-1 ELECTRIC WATER COOLER 1-1/2" 1/2"
NOTES:
1. COORDINATE MOUNTING HEIGHT OF ALL WALL MOUNTED FIXTURES WITH THE ARCHITECTURAL DRAWINGS.
A
LA B A M
A
JO
H
NN
YN . E C
H
OL
S
JO
H
NN
YN . E C
H
OL
S
ENG I NE ER
L ICENSED
No. 30043
PROFESSIONAL
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
5/2
020 4
:46:2
3 P
M
P2.0
PLU
MB
ING
FLO
OR
PLA
N -
NE
W C
ON
ST
RU
CT
ION
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
AL.
358
99
Author
02-25-2020
FPA #07519
Checker
COORDINATION
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
1/8" = 1'-0"
PLUMBING - 1ST FLOOR1/8" = 1'-0"
PLUMBING - 2ND FLOORRISER DIAGRAM- NEW CONSTRUCTION
REVISIONS
ABBREVIATION SYMBOLS SCHEDULE
GROUNDING SYMBOLS SCHEDULE
POWER SYMBOLS SCHEDULE
MANUAL MOTOR STARTER/DISCONNECT SWITCH WITH THERMAL OVERLOAD PROTECTION
DUPLEX RECEPTACLE - NEMA 5-20R WITH ISOLATED GROUND, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
SIMPLEX RECEPTACLE - NEMA 5-20R, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
DISTRIBUTION PANEL
BRANCH CIRCUIT PANELBOARD
ENCLOSED DISCONNECT SWITCH, SHADING INDICATES SWITCH IS FUSIBLE
COMBINATION MAGNETIC MOTOR CONTROLLER/STARTER, SHADING INDICATES STARTER IS FUSIBLE
ENCLOSED CIRCUIT BREAKER
TRANSFORMER
CONTROL PANEL/CONTROL POWER PANEL (FURNISHED BY OTHERS)
JUNCTION BOX, LEG INDICATES WALL MOUNTING IS REQUIRED, SQUARE INDICATES FLOOR MOUNTED
MOTOR
PUSHBUTTON STATION
CONDUIT TURNING UP
CONDUIT TURNING DOWN
INDICATES CIRCUITS TO PANEL, 'RP1' INDICATES PANEL DESIGNATION AND '1,3,5' INDICATED POLE POSITION(S)
RP1-1,3,5
'X' INDICATES QUANTITY AND 'Y' INDICATES SIZE OF CONDUCTORS, Z INDICATES CONDUIT SIZEX#Y, X#YG.,Z"C.
ABOVE FINISHED FLOORAFF
ABOVE FINISHED GRADEAFG
ELECTRICAL CONTRACTOREC
ELECTRIC WATER COOLEREWC
GROUND FAULT INTERRUPTERGFI
NATIONAL ELECTRICAL CODENEC
NOT IN CONTRACTNIC
NIGHT LIGHT - FIXTURE CONTROLLED AT BRANCH CIRCUIT BREAKERNL
NOT TO SCALENTS
WEATHERPROOF WHILE IN USE COVER/ENCLOSURE, NEMA 3R UONWP
TRANSFORMERXFMR
CADWELD CONNECTION BETWEEN GROUND CABLE AND BUILDING COLUMN
CADWELD CABLE TO CABLE 'X' CONNECTION
CADWELD CABLE TO CABLE 'T' CONNECTION
COPPERWELD TYPE GROUND ELECTRODE WITH CADWELD CONNECTION
BARE COPPER GROUND CABLE. INSTALL MINIMUM 30" BELOW FINISHED FLOOR OR GRADE
LUG CONNECTION BETWEEN BUS BAR AND CABLE
CADWELD CONNECTION BETWEEN REBAR OR ROD AND CABLE
BARE COPPER GROUND CABLE
TECHNOLOGY SYSMBOLS SCHEDULE
CPT CONTROL POWER TRANSFORMER
EPO EMERGENCY POWER OFF
RELOCATED(R)
(NOT ALLSYMBOLS USED)
(NOT ALLSYMBOLS USED)
(NOT ALLSYMBOLS USED)
(NOT ALLSYMBOLS USED)
CP
J
T
GROUND ELECTRODE TEST WELLTW
SPLIT-WIRED DUPLEX RECEPTACLE - NEMA 5-20R, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
ABOVE FINISHED CABINET/COUNTERAFC
LIGHTING SYMBOLS SCHEDULE
BATTERY POWERED EMERGENCY LIGHTING UNIT, LIGHT HEADS ON SIDES OF UNIT INDICATES CEILING MOUNTED
SURFACE OR PENDANT LIGHT FIXTURE, CHEVRON INDICATED WALL WASH AIMING, SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
(NOT ALLSYMBOLS USED)
RECESSED LIGHT FIXTURE, CHEVRON INDICATED WALL WASH AIMING, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
SURFACE OR PENDANT LIGHT FIXTURE, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
RECESSED LIGHT FIXTURE, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
XXX LIGHT FIXTURE TYPE, REFER TO LUMINAIRE SCHEDULE
SURFACE OR CHAIN HUNG STRIP LIGHT FIXTURE, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
RECESSED ARCHITECTURAL LIGHT FIXTURE, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
WALL MOUNTED LIGHT FIXTURE, HALF-SHADING INDICATES EMERGENCY EGRESS LIGHT FIXTURE
EXIT SIGN, PROVIDE ARROWS/CHEVRONS AS INDICATED ON PLANS, SHADED AREA INDICATES FACE, FOOT ON SYMBOL INDICATES WALL MOUNTED, LIGHT HEADS INDICATE COMBINATION EXIT/BATTERY POWERED EMERGENCY LIGHTING UNIT
TRACK MOUNTED LIGHT FIXTURE
XaSINGLE POLE SWITCH - 20A, 125/277V UON,
-'a' INDICATES WHICH FIXTURES/DEVICES ARE CONTROLLED VIA SWITCH-'X' DENOTES TYPE:
BLANK - SINGLE POLE2 - DOUBLE POLE3 - THREE WAY4 - FOUR WAYD - DIMMERK - KEY OPERATEDI - ILLUMINATED (ILLUMINATED IN 'OFF' POSITION)P - WITH PILOT LIGHT (LIGHT ON IN 'ON' POSITION)T - TIME SWITCHL - LOW VOLTAGEC - MOMENTARY CONTACTO - WALL BOX OCCUPANCY SENSOR - PASSIVE INFRAREDV - WALL BOX VACANCY SENSOR - PASSIVE INFRARED
OCCUPANCY/VACANCY SENSOR, FOOT ON SYMBOL INDICATES WALL MOUNTED, -'a' INDICATES WHICH FIXTURES ARE CONTROLLED VIA SENSOR-'X' DENOTES TYPE:
A - 180° DUAL TECHNOLOGY OCCUPANCY SENSORB - 360° DUAL TECHNOLOGY OCCUPANCY SENSORC - 180° PASSIVE INFRARED OCCUPANCY SENSORD - 360° ULTRASONIC OCCUPANCY SENSOR
VSXa
OSXa
VSXa
OSXa
DSa
DSa
DAYLIGHT SENSOR, FOOT ON SYMBOL INDICATES WALL MOUNTED, -'a' INDICATES WHICH FIXTURES ARE CONTROLLED VIA SENSOR
LIGHTING CONTACTOR, SIZE AS INDICATED ON DRAWINGS/DETAILC
M
DUPLEX RECEPTACLE - NEMA 5-20R, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
QUADPLEX RECEPTACLE - NEMA 5-20R, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER (ALL OTHER NEMA 5-20R QUAD RECEPTACLE SYMBOLS FOLLOW SAME STACKED DUPLEX PATTERN)
SPECIAL RECEPTACLE-'X' DENOTES TYPE:
A - (NEMA L5-30R) 125V, 30A, SINGLE PHASE, TWIST-LOCK RECEPTACLE 2 POLE, 3 WIRE B - (NEMA 6-20R) 250V, 20A, SINGLE PHASE RECEPTACLE 2 POLE, 3 WIRE C - (NEMA 6-30R) 250V, 30A, SINGLE PHASE RECEPTACLE, 2 POLE, 3 WIRE D - (NEMA L6-20R) 250V, 20A, SINGLE PHASE, TWIST-LOCK RECEPTACLE 2 POLE, 3 WIRE E - (NEMA L15-30R) 250V, 30A, THREE PHASE, TWIST-LOCK RECEPTACLE, 3 POLE, 4 WIRE F - (NEMA L21-30R) 208Y/120V, 30A, THREE PHASE, TWIST-LOCK RECEPTACLE 4 POLE, 5 WIRE G - (NEMA 14-30R) 125/ 250V SINGLE PHASE RECEPTACLE 3 POLE, 4 WIRE H - (NEMA 6-50R) 250V SINGLE PHASE RECEPTACLE 2 POLE, 3 WIRE I - (NEMA 14-50R) 250V
SINGLE POINT ELECTRICAL CONNECTION
DUPLEX RECEPTACLE - NEMA 5-20R, GROUND FAULT INTERRUPTING, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
COMBINATION DUPLEX RECEPTACLE (NEMA 5-20R)/USB (TYPE A, 2.0 ), TWO CHARGING USB PORTS, HORIZONTAL LINE INDICATES MOUNTED AFC UON, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
X
X
CEILING MOUNTED SIMPLEX RECEPTACLE - NEMA 5-20R, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
CEILING MOUNTED DUPLEX RECEPTACLE - NEMA 5-20R, SHADING INDICATES CIRCUITED TO GENERATOR/UPS POWER
CEILING MOUNTED SPECIAL RECEPTACLE-'X' DENOTES TYPE:
REFER TO WALL MOUNTED SPECIAL RECEPTACLE TYPES ABOVE
CB
J
MAGNETIC MOTOR CONTROLLER
J
VARIABLE FREQUENCY DRIVE (FURNISHED BY OTHERS)VFD
AUTOMATIC TRANSFER SWITCHATS
MANUAL TRANSFER SWITCHMTS
M UTILITY METER
FLOOR BOX, 'X' INDICATES TYPE, REFER TO FLOOR BOX SCHEDULEFBX
PTX POKE THRU, 'X' INDICATES TYPE, REFER TO FLOOR BOX SCHEDULE
MOTOR CONTROL CENTER
MULTI-OUTLET SURFACE RACEWAY
UNLESS OTHERWISE NOTEDUON, UNO
(RR) REMOVE AND RELOCATE
EXISTING TO REMAIN(E)
POWER SUPPLYPS
GENERATOR ANNUNCIATORGA
BUILDING MANAGEMENT SYSTEM PANEL (FURNISHED BY OTHERS)BMS
FIRE ALARM CONTROL PANEL (FURNISHED BY OTHERS)FACP
FAA FIRE ALARM ANNUNCIATOR (FURNISHED BY OTHERS)
FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT PANEL (FURNISHED BY OTHERS) FNAC
ELECTRICALLY OPERATEDEO
AMP FRAME - CIRCUIT BREAKER; AMP FUSE - FUSED SWITCHAF
AMPERESA, AMP
AMPERES TRIPAT
AMPERE INTERRUPTING CAPACITYAIC
AUTOMATIC TRANSFER SWITCHATS
CONDUITC
CURRENT TRANSFORMERCT
EMERGENCYEM
FULL LOAD AMPERESFLA
GROUNDG, GND
HAND-OFF-AUTOHOA
HORSEPOWERHP
KILOVOLTKV
KILOVOLT-AMPERESKVA
KILOWATTKW
KILOWATT-HOURSKWH
MAIN CIRCUIT BREAKERMCB
MECHANICAL CENTRAL POWERMCP
MAIN LUGS ONLYMLO
NEUTRALN
NORMALLY CLOSEDNC
NORMALLY OPENNO
ON CENTEROC
POLEP
PHASEPH
POTENTIAL TRANSFORMERPT
RECEPTACLERECEPT
LIGHTSLTS
DISHWASHERDW
MICROWAVEMW
REF REFRIGERATOR
GARBAGE DISPOSALGD
TR TAMPER-RESISTANT
TYP TYPICAL OF LIKE DEVICES IN SAME AREA
VOLTSV
WIREW
EXPLOSION PROOFXP, EP
ALUMINUMAL
COPPERCU
EXISTING, REMOVE AND REPLACE WITH NEW IN SAME LOCATION(XRP)
DRAWING CONVENTIONS
NEW WORK
EXISTING TO REMAIN(E)
EXISTING TO REMOVE (DEMOLISHED)
HATCHED EXISTING TO REMOVE (DEMOLISHED)
UNINTERUPTABLE POWER SUPPLYUPS
COFFEE MAKER/MACHINECM
HORIZONTAL/HORIZONTALLY MOUNTEDH
ARC FAULT INTERRUPTERAFI
CRITICAL / CRITICAL BRANCH EMERGENCYCR
ELTD , GTD EMERGENCY LOAD/GENERATOR TRANSFER DEVICE
EDIT ITEMS IN () TO SUIT PROJECT
RP1 PANEL TAG, i.e. CIRCUITS WITHIN AREA WHERE TAG IS LOCATED ON PLAN ARE CIRCUITED TO PANEL 'RP1' UON
EQUIPMENT GROUNDEG
TIME CLOCKTC
LS LIFE SAFETY BRANCH EMERGENCY
EQUIPMENT BRANCH EMERGENCYEQ
ICE MACHINEIM
LIGHTING CONTROL POINTCP
J
1'-6"
4'-0"
6'-6"
NOTES:
1.
2.
3.
4.
MOUNTING HEIGHTS SHOWN ARE FROM FINISHED FLOOR TO CENTERLINE OF DEVICE/OUTLET/FIXTURE, UNLESS OTHERWISE NOTED.
MOUNTING HEIGHTS, WHERE INDICATED, ON FLOOR PLANS, SHALL TAKE PRECEDENCE OVER THESE MOUNTING HEIGHTS. LOCATIONS OF OUTLETS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL TAKE PRECEDENCE OVER THESE MOUNTING HEIGHTS. FIELD LOCATE OUTLETS WITH ARCHITECT DURING ROUGH-IN.
INSTALL OUTLETS THAT ARE IN CLOSE PROXIMITY ON THE SAME CENTERLINE. OUTLETS THAT ARE WITHIN 2'-0" HORIZONTALLY AND WITHIN 1'-0" VERTICALLY SHALL BE INSTALLED ON THE SAME HORIZONTAL CENTERLINE LOCATED HALF WAY BETWEEN THE HEIGHTS SHOWN. OUTLETS THAT ARE MORE THAN 1'-0" APART VERTICALLY SHALL BE INSTALLED ON THE SAME VERTICAL CENTERLINE.
MAXIMUM MOUNTING HEIGHT FOR SWITCHES ABOVE A COUNTER TOP 20" DEEP OR LESS IS 48" AFF TO TOP OF BOX. SWITCHES MOUNTED ABOVE COUNTER TOPS DEEPER THAN 20" SHALL BE INSTALLED AT NO MORE THAN 44" AFF FLOOR TO TOP OF BOX. NOTIFY ARCHITECT WHERE COUNTERTOP PROHIBITS SWITCH INSTALLTION.
STANDARD MOUNTING HEIGHTS
S
6" ABOVECOUNTERWITHOUTBACKSPLASH
4" ABOVEBACKSPLASH
FINISHED FLOOR
W
F
4'-6"
6'-8"
THIS DIMENSION TO TOP OF BOX
FLOOR BOX S C H E D U L E
FB1
DEVICE DESCRIPTION
NOT USED
FB2RECESSED FLUSH-IN-FLOOR POKE-THRU 8 INCH BOX WITH (2) 20-A DUPLEX OUTLETS AND (8) RJ45 JACKS FOR DATA, 5 GANG CAPACITY (1 SPARE) WITH 2 HOUR FIRE RATING. LEGRAND #8CTC2BS.
PLENUM RATED STP CAT6 (475mHz 10G MIN.) TERMINATE T568B, CABLE QUANTITY IDENTIFIED
CAT-6 CABLE, QUANTITY IDENTIFIED
COMBINED DATA OUTLET, FLOOR BOX
2-PORT PLENUM RATED STP CAT6 (475mHz 10G MIN.) TERMINATE T568BTV
WIRELESS ACCESS POINT, CEILING MOUNTED (2) CAT-6AWAP
DATA OUTLET, FLOOR BOX
TELECOMMUNICATIONS BACKBOARD (FIRE RATED)
PRIMARY BONDING BUSBAR-PANDUIT GB2B0306TPI-1PBB
FIRE ALARM HORN WITH STROBE, CEILING MOUNTED
FIRE ALARM STROBE, MH=6'-8" AFF UNO
VIDEO SURVEILLANCE SYSTEM FIXED VIEW, CEILING MOUNTED
CARD READER, MH=4'-0" AFF UNOCR
F
AOM FIRE ALARM ADDRESSABLE OUTPUT MODULE
J JUNCTION BOX
PUBLIC ADDRESS SPEAKER, CEILING MOUNTEDS
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:4
1 P
M
E0.1
ELE
CT
RIC
AL
LEG
EN
D, S
YM
BO
LS, &
NO
TE
S
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
C.SHELTON
2020-02-25
FPA#07519
A.YORK
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
REVISIONS
NOTES ON WIRINGQS CONTROL LINKTHE QS CONTROL LINK HAS A FREE WIRING TOPOLOGY (DAISY CHAIN, T-TAP, ETC). THE SYSTEM WIRING
ILLUSTRATED BY THIS DRAWING HAS BEEN LAID OUT TO ENSURE APPROPRIATE POWER TO EACH DEVICE. IF FOR
ANY REASON THE SYSTEM IS TO BE WIRED DIFFERENTLY THAN WHAT IS SHOWN, PLEASE CONFIRM ALL DEVICE
POWER REQUIREMENTS ARE MET (PLEASE REFER TO “QS LINK POWER REQUIREMENTS” FOR INDIVIDUAL DEVICE
POWER REQUIREMENTS).
FOR QS CONTROL WIRE LENGTHS TOTALING LESS THAN 500 FT (153 M), USE LUTRON CABLE GRX-CBL-346S (4
CONDUCTOR NON-PLENUM), OR GRX-PCBL-346S (4 CONDUCTOR PLENUM). OTHERWISE USE 2 #18 AWG (1.0 SQ MM) +
2 #22 AWG (0.5 SQ MM) TWISTED AND SHIELDED OR EQUIVALENT (BELDEN #9461). FOR QS CONTROL WIRE LENGTHS
TOTALING UP TO 2,000 FT, USE GRX-CBL-46L (4 CONDUCTOR NON-PLENUM) OR GRX-PCBL-46L (4 CONDUCTOR
PLENUM). TOTAL QS CONTROL WIRE LENGTH MUST NOT EXCEED 2,000 FT (600 M).
QS LINK POWER REQUIREMENTS
DEVICE PDUS
QS DEVICES THAT SUPPLY PDU
DIN RAIL POWER SUPPLY +75
MYROOM DIN RAIL POWER SUPPLY +30
QS PLUG-IN POWER SUPPLY, QS J-BOX POWER SUPPLY +8
ENERGI SAVR NODE WITH ECOSYSTEM, ENERGI SAVR NODE WITHDALI, ENERGI SAVR NODE WITH T-SERIES TUNABLE-WHITE
+30
ENERGI SAVR NODE FOR 0–10 V, ENERGI SAVR NODE WITHSOFTSWITCH, ENERGI SAVR NODE FOR 0–10 V (DIN RAIL), ENERGISAVR NODE WITH SOFTSWITCH (DIN RAIL)
+14
ENERGI SAVR NODE PHASE ADAPTIVE (DIN RAIL), 1 A MYROOM DINRAIL POWER MODULE SWITCHING, 1 A MYROOM DIN RAIL POWERMODULE PHASE ADAPTIVE
+4
ENERGI SAVR NODE WITH DALI (DIN RAIL), ENERGI SAVR NODE WITHECOSYSTEM (DIN RAIL)
+3
QS MOTOR GROUP CONTROLLER (DIN RAIL), HOMEWORKS QS DINRAIL POWER MODULES
0
GRAFIK EYE QS (ALL MODELS EXCEPT GRAFIK EYE QS DALI WITHKNX), QS TIMECLOCK
+3
QP2 QUANTUM LIGHTING HUBLINK A : 0LINKS B,C,D : +33 EACH
QP3 QUANTUM LIGHTING HUB LINKS A,B : +33 EACH
QS DEVICES THAT CONSUME PDU
QS WALLSTATION (SEETOUCH, ARCHITRAVE, SIGNATURE SERIES, QSPICO, KEYSWITCH, SINGLE COLUMN PALLADIOM), QS SLIDER, GRAFIKT SLIDER, QS INFRARED (IR) EYE, WALLBOX INPUT CLOSUREINTERFACE
-1
QS NETWORK INTERFACE, QS DMX INTERFACE, ENERGI SAVR NODEPROGRAMMING INTERFACE, QS WALLSTATION (DOUBLE COLUMNPALLADIOM)
-2
QS SENSOR MODULE (QSM), NOT INCLUDING ATTACHED WIREDSENSORS (SEE SECTION BELOW FOR MORE INFORMATION), QSCONTACT CLOSURE INTERFACE, PALLADIOM ROOM THERMOSTAT
-3
GUESTROOM CONTROL UNIT -8
SENSORS & DEVICES THAT CONSUME PDUS WHEN WIRED TO A QSM
LUTRON DAYLIGHT SENSOR, LUTRON INFRARED (IR) RECEIVER, PICOWIRED CONTROLLER
-0.5
ECOSYSTEM WALLSTATION -1
LOS C SERIES OCCUPANCY SENSOR, HIGH BAY OCCUPANCY SENSOR -2
120V
#1QSPS-10PNLFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - Power Supply 002QS Smart Panel
120V
#2QSPS-10PNLFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - Power Supply 001QS Smart Panel
GRX-TVI120 V
GRX-TVI120 V
GRX-TVI120 V
GRX-TVI120 V
RF
120V
#3QSGRJ-4P-WHFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - Control Station 001GRAFIK Eye QS Wireless 4 zoneScenes 1-4 + Off4 gang backbox
0-1
0V
Cyber Labc506 W of LED 0-10LZ4 (11)
1
0-1
0V
Cyber Laba230 W of LED 0-10LZ4E (5)
2
0-1
0V
Cyber Labb46 W of LED 0-10LZ4E (1)
3
0-1
0V
Cyber Labd276 W of LED 0-10LZ4 (6)
4
RF
LUTRON
PJ2-4B-GWH-L31Floor 1\E1-2 - SECOND FLOOR PLAN - LIGHTING\CyberLab - Control Station 0044 Button Scene with Light Icon - Pico KeypadScenes 1-3 + Off
RF
LUTRON
PJ2-4B-GWH-L31Floor 1\E1-2 - SECOND FLOOR PLAN - LIGHTING\CyberLab - Control Station 0054 Button Scene with Light Icon - Pico KeypadScenes 1-3 + Off
LUT-ELI-3PHFloor 1\E1-2 - SECONDFLOOR PLAN -LIGHTING\Cyber Lab -Emergency LightingInterface 001Emergency Lighting Interface
Fire Alarm Control Panel(Contact Closure Input)
E
#4QSE-CI-NWK-EFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - Network Interface 001QS Ethernet & RS232 Control Interface
To Ethernet (Not Provided by Lutron)
QLink 1
To sheet 2 (2 Devices on T-Tap)
T1
#5QSWS2-3BDI-WHFloor 1\E1-2 - SECOND FLOOR PLAN- LIGHTING\Cyber Lab - ControlStation 002seeTouch QS Dual Insert 3 ButtonScenes 1-2 + Off, Scenes 1-31 gang backbox
#6QSWS2-3BDI-WHFloor 1\E1-2 - SECOND FLOOR PLAN- LIGHTING\Cyber Lab - ControlStation 003seeTouch QS Dual Insert 3 ButtonScenes 1-2 + Off, Scenes 1-31 gang backbox
120/277V
QSPS-J-1-35VFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - J-Box Power Supply002J-Box Power Supply can support one shadeor supply up to 8 PDU’s on a QS Link.
#7QSE-IOFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - IO 001QS Contact Closure Input/Output ControlInterfaceScenes 1-4 + Off
120/277V
QSPS-J-1-35VFloor 1\E1-2 - SECOND FLOOR PLAN -LIGHTING\Cyber Lab - J-Box Power Supply001J-Box Power Supply can support one shadeor supply up to 8 PDU’s on a QS Link.
QLink 1 QLink 1 QLink 1 QLink 1 QLink 1
QLink 1 QLink 1
QLink 1
T1
Link 1
Q
Q
D
E
F
P
3
P
S
P
T
T
Wire Legend
2 #12 AWG (4 sq mm) + ground
3 #12 AWG (4 sq mm) + ground
Panel Control Link (Connect wires 1, 2, 3, 4and 5)*
EcoSystem Bus/Loop*
DALI Loop
Lutron Sensor Cable C-CBL-522S or use3#22 AWG (1.0 sq mm)
DMX Cable. Use LutronGRX-CBL-DMX-250/GRX-CBL-DMX-500 orBeldon #9729 (Non-plenum) or Beldon#89729 (Plenum) or Dura Flex 22/4 WA Cable.
Lutron Sensor Cable C-CBL-522S or use4#22 AWG (1.0 sq mm)
QS Control Link (Connect wires 1, 3 and 4. Donot connect wire 2)*
RF Connection
Wired Connection
QS Control Link (Connect wires 1, 2, 3 and 4)*
Panel Control Link (Connect wires 1, 2, 3 and4. Do not connect wire #5)*
Normal Input Power 2 #12 AWG (4 sq mm) +ground
QS Sivoia Shade Control Link*
Normal-Emergency Input Power 2 #12 AWG(4 sq mm) + ground
3 Phase 4 wire Input Power, 4 #12 AWG (4sq mm) + ground
0-10 V Signal: 2#18AWG (1.0 sq mm)
2#18 AWG (1.0 sq mm)
3#18 AWG (1.0 sq mm)
Ethernet cable. CAT5E or better cable forLutron Network terminated with RJ45connectors (not provided by Lutron). 328 ft(100 m) maximum run.
Fiber optic cable for Lutron Networkterminated with appropriate fiber opticconnectors (not provided by Lutron). Requiresdedicated fiber optic link (single-mode ormulti-mode)
Panel Control Link (Connect wires 1, 3, 4 and5. Do not connect wire #2)*
T-Series Tunable-White Loop
Belden Cable 1387LA(Or Equivalent)
(28) (30) (1)
(36)
(36)
(38)
(38)
(32) (34)
LIGHTING RISER DIAGRAM* ALL CIRCUITS SHOWN (X) HOMERUN TO PANEL RP-2C.
7200 Suter RoadCoopersburg, PA 18036, USA+1.610.282.3800 | Fax: +1.610.282.1146
*Refer to Panel Schedule for feed and load information
VS
B
6 X VS
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:4
2 P
M
E0.2
ELE
CT
RIC
AL
SC
HE
DU
LES
& L
IGH
TIN
G R
ISE
R D
IAG
RA
M
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
C.SHELTON
2020-02-25
FPA#07519
A.YORK
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
LIGHTING FIXTURE SCHEDULETYPE LAMPS DESCRIPTION VOLTAGE MANUFACTURER APPARENT LOAD COUNT
LR6 LED, 4000K RECESSED DOWNLIGHT, 6-IN. DIA., SEMI-SPECULAR ALZAK REFLECTOR, 0-10V DIMMING, MINIMUM 4,000 LUMENS 277 V ACUITY:LDN6-40/40-LO6-AR-LSS-MVOLT-EZ10-HAO
44 VA 15
LR6E LED, 4000K SAME AS 'LR6', BUT ON LIFE SAFETY EMERGENCY CIRCUIT 277 V ACUITY:LDN6-40/40-LO6-AR-LSS-MVOLT-EZ10-HAO
44 VA 3
LZ4 LED, 3500K 2' x 2' RECESSED LUMINAIRE, ARCHITECTURAL BASKET LENS, ALUMINUM HOUSING , MINIMUM 5,000 LUMENS, 0-10V DIMMING 120 V CREE 39 VA 17
LZ4E LED, 3500K SAME AS FIXTURE LZ4 EXCEPT COMPLETE WITH EMERGENCY POWER 120 V CREE 39 VA 6
LZ5 LED, 4000K 2' x 4' RECESSED LUMINAIRE, ARCHITECTURAL BASKET LENS, ALUMINUM HOUSING, MINIMUM 4,800 LUMENS 277 V ACUITY:2ALL4-CTRF-48L-EZ1-LP840-N100
46 VA 13
LZ5E LED, 4000K SAME AS 'LZ5', BUT ON LIFE SAFETY EMERGENCY CIRCUIT 277 V ACUITY:2ALL4-CTRF-48L-EZ1-LP840-N100
46 VA 12
XAP LED UNIVERSAL MOUNTED L.E.D. EXIT SIGN, WITH DIE-CAST ALUMINUM HOUSING AND NATURAL BRUSHED ALUMINUM STENCILFACEPLATE AND TRIM WITH RED LETTERS. LUMINAIRE SHALL CONTAIN A MULTITUDE OF ULTRA LONG LIFE L.E.D.'SMOUNTED ON A PRINTED CIRCUIT BOARD. TOTAL WATTAGE NOT TO EXCEED 3 WATTS FOR A SINGLE FACE AND 6 WATTSFOR A DOUBLE FACE UNIT. L.E.D.'S SHALL BY PROTECTED BE A CLEAR PANEL AND OPTICAL DIFFUSER.
277 V LITHONIA:LE-S-1/2-R-120/277-ELN
3 VA 9
XBP LED UNIVERSAL MOUNTED L.E.D. EXIT SIGN, WITH PRECISION-MOLDED THERMO PLASTIC HOUSING AND STENCIL FACEPLATE ANDTRIM. FIXTURE SHALL CONTAIN A MULTITUDE OF ULTRA LONG LIFE L.E.D.'S MOUNTED ON A PRINTED CIRCUIT BOARD. TOTALWATTAGE NOT TO EXCEED 3 WATTS FOR A SINGLE FACE AND 6 WATTS FOR A DOUBLE FACE UNIT. L.E.D.'S SHALL BYPROTECTED BE A CLEAR PANEL AND OPTICAL DIFFUSER. HIGH OUTPUT LEAD CALCIUM BATTERY PACK
277 V LITHONIA CATALOGNUMBER-LQM-S-W-(1 OR 3 ASINDICATED ON THEDRAWINGS)-R-120/277,EL-H0-SD, OR EMERGI-LITE, ORSURE-LITE OR PRESCOLITE ORCHLORIDE CATALOG No.CXLA1RN
5 VA 4
XCP LED UNIVERSAL MOUNTED L.E.D. EXIT SIGN, WITH PRECISION-MOLDED THERMO PLASTIC HOUSING AND STENCIL FACEPLATE ANDTRIM. FIXTURE SHALL CONTAIN A MULTITUDE OF ULTRA LONG LIFE L.E.D.'S MOUNTED ON A PRINTED CIRCUIT BOARD. TOTALWATTAGE NOT TO EXCEED 3 WATTS FOR A SINGLE FACE AND 6 WATTS FOR A DOUBLE FACE UNIT. L.E.D.'S SHALL BYPROTECTED BE A CLEAR PANEL AND OPTICAL DIFFUSER. HIGH OUTPUT LEAD CALCIUM BATTERY PACK
120 V LITHONIA CATALOGNUMBER-LQM-S-W-(1 OR 3 ASINDICATED ON THEDRAWINGS)-R-120/277,EL-H0-SD, OR EMERGI-LITE, ORSURE-LITE OR PRESCOLITE ORCHLORIDE CATALOG No.CXLA1RN
20 VA 2
XRL LED, 4000K 2' x 4' RECESSED LUMINAIRE, ARCHITECTURAL BASKET LENS, ALUMINUM HOUSING, MINIMUM 4,800 LUMENS 120 V ACUITY:2ALL4-CTRF-48L-EZ1-LP840-N100
46 VA 2
A. REFER TO ARCHITECTURAL REFLECTED CEILINGPLANS FOR EXACT LOCATION OF ALL LIGHTINGFIXTURES UNLESS NOTED OTHERWISE.
B. REFER TO THE LUMINAIRE SCHEDULE LOCATED ONTHE ELECTRICAL GENERAL INFORMATION DRAWING.
C. ALL ELECTRICAL DEVICES INDICATED ON THIS PLANSHALL BE NEW UNLESS NOTED OTHERWISE.
D. LIGHT SWITCHES SHALL BE GROUPED UNDER ONECOMMON FACEPLATE WHERE MORE THAN ONE LIGHTSWITCH IS INDICATED TO BE INSTALLED AT THE SAMELOCATION.
E. ALL EXISTING LIGHTING INDICATED TO REMAIN SHALLBE RELAMPED AND CLEANED. REPAIR EXISTINGFIXTURES THAT ARE MALFUNCTIONING WHEREFEASIBLE. OTHERWISE REPLACE WITH NEW. REVISECIRCUITING AS INDICATED.
F. ALL LIGHTING BRANCH CIRCUIT WIRING ASSOCIATEDWITH NEW LIGHTING SHALL BE 2#12, 1#12GND IN 3/4"CUNLESS NOTED OTHERWISE.
G. ALL EXISTING EQUIPMENT/DEVICES NOTSPECIFICALLY INDICATED TO BE DEMOLISHED SHALLREMAIN OPERATIONAL. REVISE EXISTING CIRCUITINGTO MAINTAIN OPERATION TO SUCHEQUIPMENT/DEVICES AS REQUIRED.
H. REUSE THE EXISTING BRANCH CIRCUIT CONDUIT ANDWIRING ASSOCIATED WITH THE LIGHTING FIXTURESREMOVED DURING DEMOLITION TO REFEED NEWLIGHTING FIXTURES UNLESS NOTED OTHERWISE.REWORK THE EXISTING CIRCUIT TO PROVIDELIGHTING CONTROL AS INDICATED ON THIS DRAWING,UNLESS NOTED OTHERWISE.
I. ALL EXISTING LIGHTING INDICATED AS TO REMAINAND LOCATED IN AREAS WHERE THE CEILING ISBEING MODIFIED SHALL BE TEMPORARILYSUPPORTED AND REINSTALLED UPON COMPLETIONOF CEILING REVISIONS. COORDINATE WITHARCHITECTURAL REFLECTED CEILING PLANS ANDARCHITECTURAL TRADE.
J. ALL NIGHT LIGHT AND EXIT SIGNS SHALL BEUNCONTROLLED AND CONNECTED AHEAD OF THELOCAL LIGHTING CONTROLS.
K. ALL CONDUITS INSTALLED IN FINISHED AREAS SHALLBE ROUTED CONCEALED UNLESS NOTEDOTHERWISE.
L. ALL NOTES ADDED WILL APPEAR ON ALL DRAWINGSTHAT ARE OF THIS TYPE. NUMBERS WILL ALSO BETHE SAME TO PROMOTE CONSISTENCY.
GENERAL NOTES
Receptacle 21340 VA 73.43% 15670 VA Total Est. Demand: 67 A
Other 2261 VA 100.00% 2261 VA Total Conn.: 83 A
Lighting 1029 VA 100.00% 1029 VA Total Est. Demand: 24224 VA
HVAC 3264 VA 100.00% 3264 VA Total Conn. Load: 29894 VA
Equipment 2000 VA 100.00% 2000 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 75 A 116 A 62 A
Total Load: 8798 VA 13674 VA 7422 VA
41 0 0 1 20 A Spare 42
39IU-217 20 A 2
HACR STYLEBREAKER
3264 0 1 20 A Spare 40
37 Spare 20 A 1 0 0 1 20 A Spare 38
35 Spare 20 A 1 0 0 1 20 A Spare 36
33 Spare 20 A 1 0 400 1 20 A SHADE POWER SUPPLY 34
31 Spare 20 A 1 0 400 1 20 A SHADE POWER SUPPLY 32
29 Spare 20 A 1 0 730 30
27 EWC 20 A 1 600 7302 20 A LIGHTING QS PANEL
28
25 800 600 1 20 A Receptacle TV CYBER LOUNGE 26
23FL BOX CYBER LOUNGE 20 A 2
2-120V W/ HANDLETIE
800 800 24
21 800 800 2/120V W/ HANDLETIE
2 20 A FL BOX LAB EAST22
19FL BOX LAB SE 20 A 2
2-120V W/ HANDLETIE
800 800 20
17 800 800 2-120V W/ HANDLETIE
2 20 A FL BOX LAB NE18
15FL BOX LAB CENTER 20 A 2
2-120V W/ HANDLETIE
800 800 16
13 800 800 2-120V W/ HANDLETIE
2 20 A FL BOX LAB SW14
11FL BOX LAB NW 20 A 2
2-120V W/ HANDLETIE
800 800 12
9 Receptacle LAB DESK NE 20 A 1 1080 800 2-120V W/ HANDLETIE
2 20 A FL BOX LAB WEST10
7 Receptacle TV SOUTH LAB 20 A 1 720 540 1 20 A Receptacle TV WEST LAB 8
5 Recpt / LTS 217,219 20 A 1 932 960 1 20 A Receptacle TV EAST LAB 6
3 Receptacle DATA RACK 20 A 1 1600 2000 1 30 A SP PURPOSE DATA RACK 4
1 GRAPHIC EYE 20 A 1 938 1600 1 20 A Receptacle DATA RACK 2
CKT Circuit Description Trip P Comments A B C Comments P Trip Circuit Description CKT
Notes:
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains Rating: 100 A
Supply From: Phases: 3 Mains Type: MLO
Location: LAB SUPPORT 217 Volts: 208Y/120V Wye A.I.C. Rating: 14,000
RP-2C
REVISIONS
J
J
J
J
J
J
J
J
J
J
J
1 2 3 4 5 6
8 97
H
G
F
E
D
C
B
A
EXIST. CORRIDOR207
EXIST. CORRIDOR211
RECEPTION202A
BALCONY230
COMPUTERCLASSROOM
206
EXIST. CLASSROOM209
MEN228
EXISTING ELEC.229
PBX237
WOMEN235
EXISTING PORCH208
EX. SERVER ROOM238
EXISTING CORRIDOR231
EXISTING CLOSET236
EXIST. JANITOR227
EXIST. COPY RM225
EXIST. ELEV.239
EXISTINGMECHANICAL
240
EXIST. ELEV.239B
EXISTINGMECHANICAL
223
EXIST. CLASSROOM232C
EXIST. CLASSROOM205
EXIST. CLASSROOM220
EXIST. CLASSROOM224
EXIST. CLASSROOM222
OFFICE202F
OFFICE202G
SECRETARY202J
CONFERENCE ROOM242
STOR.202K
TOIL.202H
OFFICE241
STAIRS219
UTILITY238B
AIRLOCK233
XR
XR
XR
XR XR XR
XR
XR XR
XR XR
XR
XR
XR
XR
XR
XR
XR
XRXR
XR
XR
XR
XR
EX
EX EX
XR
XR XR
XR XR XR
XR
XR
XR
XR
XR
XR XR XR
XR
3
5 TYP
1
4
7
6
6 6
6
2
2
EX
EX
EX
EX
EX
EX
EX
EX
XR
XR
XR
XR
XRR
XR
XR
XR
XR
XR
8
8
9
9
9
F F
XR XR
F F
XR XR
F FXRR XRR
2
XR
F FXRR XRRF FXRR XRR
F
F
XRR
XRRXR
EX
F
XRR
XRRXRR
EX
EX
F FXRR XRR
EX
XR
F
EX
F XRR
F XRR
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:4
5 P
M
E1.1
OV
ER
ALL
SE
CO
ND
FLO
OR
DE
MO
LIT
ION
PLA
N -
ELE
CT
RIC
AL
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
C.SHLETON
2020-02-25
FPA#07519
A.YORK
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
SCALE: 1/8" = 1'-0"E1.1
1 OVERALL SECOND FLOOR DEMOLITION PLAN - ELECTRICAL
KEY PLAN
GENERAL NOTES
PLAN NOTES
A. SELECT DEMOLITION MAY BE REQUIRED FOR NEWCONSTRUCTION AND MAY NOT BE DELINEATED ONTHIS DRAWING. CAREFULLY COORDINATEDEMOLITION WITH NEW CONSTRUCTION PLANS OFALL DISCIPLINES TO VERIFY ACTUAL EXTENT OFDEMOLITION. VISIT THE SITE PRIOR TO SUBMISSIONOF BID TO EXAMINE THE EXISTING CONDITIONS ANDFULLY UNDERSTAND THE EXTENT OF DEMOLITIONWORK.
B. EXAMINE THE DRAWINGS OF OTHER TRADES AND BEFAMILIAR WITH THE DEMOLITION REQUIRED BYOTHER TRADES. PERFORM ALL INCIDENTALELECTRICAL DEMOLITION AND/OR RELOCATIONREQUIRED TO FACILITATE THE DEMOLITION WORK OFOTHER TRADES, WHETHER OR NOT SPECIFICALLYINDICATED.
C. QUANTITY AND LOCATION OF DEVICES SHOWN ONPLANS ARE APPROXIMATE. FIELD VERIFY DEVICESAND LOCATIONS.
D. ITEMS SHOWN HEAVY LINE WEIGHT DASHED LINES,HATCHED AND/OR NOTED SHALL BE DEMOLISHEDAND ALL ASSOCIATED DEVICES, CONDUIT, ANDWIRING SHALL BE REMOVED BACK TO THE NEARESTACTIVE JUNCTION BOX OR SOURCE UNLESS NOTEDOTHERWISE.
E. ALL EXISTING EQUIPMENT MAY NOT BE INDICATED.CONTRACTOR SHALL FIELD VERIFY EXISTINGCONDITIONS PRIOR TO BIDDING. EXISTING ITEMSNOT SHOWN HATCHED SHALL REMAIN IN OPERATION.REVISE THE EXISTING CIRCUITRY TO MAINTAINOPERATION OF ITEMS TO REMAIN.
F. PROVIDE PROPER SUPPORT FOR EXISTING TOREMAIN CONDUITS AND BOXES WHERE EXISTINGSUPPORT IS TO BE REMOVED. RE-ROUTE BRANCHCIRCUIT CONDUITS AND RELOCATE JUNCTION BOXESAS REQUIRED TO FACILITATE INSTALLATION OF NEWEQUIPMENT AND SYSTEMS IN CEILING SPACES.
G. COORDINATE WITH NEW WORK PLANS, ONE LINEDIAGRAMS AND RISER DIAGRAMS FOR EXTENT OFDEMOLITION WORK.
H. CIRCUITING SHOWN IS BASED ON CASUAL FIELDOBSERVATIONS AND/OR AS-BUILT DRAWINGS.CONTRACTOR SHALL FIELD VERIFY CIRCUITING.
I. MAINTAIN ELECTRICAL SERVICE TO ALL LIGHTINGFIXTURES, DEVICES AND EQUIPMENT THAT ARE TOREMAIN. EXTEND CONDUIT AND WIRE AS REQUIREDWHERE DEMOLITION WORK AFFECTS ELECTRICALSERVICE TO DOWNSTREAM LOADS THAT ARE TOREMAIN.
J. RECYCLE OR DISPOSE OF ALL MATERIALS OFF SITEAND INCLUDE ALL ASSOCIATED COSTS IN BID. ALLMATERIALS SHALL BE DISPOSED OF IN ACCORDANCEWITH ALL FEDERAL, STATE, AND LOCALREGULATIONS, INCLUDING LEED REQUIREMENTS,TCLP TESTING, PROPER DISPOSAL AND/ORRECYCLING OF FLUORESCENT LAMPS.
K. PROVIDE BLANK COVER PLATES WHERE DEVICESARE REMOVED BUT EXISTING WALLS/CEILINGSREMAIN INTACT.
L. RING OUT AND TAG ALL CIRCUITS AFFECTED BY THISALTERATION AT BOTH ENDS. MARK ALL UNUSEDCIRCUIT BREAKERS “SPARE” AND PLACE IN THE "OFF"POSITION.
M. VERIFY ALL UNDERGROUND AND IN SLAB UTILITYLOCATIONS PRIOR TO SAW-CUTTING ORPENETRATING ANY FLOOR SLAB.
N. OFFER OWNERS REPRESENTATIVE FIRST RIGHT OFREFUSAL OF ALL EQUIPMENT REMOVED FROMSPACE.
O. PROVIDE CODE-COMPLIANT SUPPORT TOEXISTING-TO-REMAIN UNSUPPORTED CONDUITS ANDBOXES WHERE CEILINGS ARE TO BE REMOVED.RE-ROUTE BRANCH CIRCUITS AND RELOCATEJUNCTION BOXES AS REQUIRED TO FACILITATEINSTALLATION OF NEW EQUIPMENT AND SYSTEMS INCEILING SPACES.
1. EXISTING WALL MOUNTED CLOCKS TO REMAINTYPICAL WITHIN CORRIDORS 207, 231, AND 211.
2. EXISTING WALL MOUNTED SWITCH ANDRECEPTACLE DEVICES TO REMAIN. COVER PLATESTO BE REPLACED WITH STAINLESS STEEL, TYPICALALL.
3. ALL AUXILIARY DEVICES STILL IN USE TO BEREMOVED FROM EXISTING CEILING, HUNG ANDSUPPORTED, AND RE-INSTALLED WITHIN NEWCEILING TILE. INCLUDES FIRE ALARM DETECTORS,VISUAL / AUDIO DEVICES, WIFI ANTENNAS, ETC.
4. EXISTING WALL MOUNTED JUCNTION BOXES NOLONGER IN USE OR ABANDONED SHALL HAVE WIREAND BOXES REMOVED AND OPENINGS PATCHED TOMATCH EXISTING FINISHES.
5. EXISTING LIGHTING AND EXIT SIGNAGE TO BEDEMOLISHED. CIRCUITS TO BE CAPPED IN BOXESAND RE-USED FOR NEW LIGHTING IN CORRIDORS207, 231, AND 211.
6. REMOVE AND RETURN EXISTING LUMINAIRES,CONTROLS, AND LIGHTING MODULES IN THIS ROOMTO OWNER DESIGNATED LOCATION ON CAMPUS.TWO OF THE 2X4 LUMINAIRES TO BE RELOCATED(XRL) IN THE LABE SUPPORT ROOM, SEE LIGHTINGDRAWINGS.
7. EXISTING FIRE ALARM CONTROL PANEL (FACP)LOCATED IN MEZZANINE ROOM BELOW.
8. EXISTING CIRCUITS MADE AVAILABLE FROMDEMOLITION (AND NOT THOSE CONTINUED) SHALLHAVE WIRING PULLED BACKTO PANEL AND CONDUIT/ CABLE REMOVED FROM THE CEILING. UPDATEPANEL DIRECTORY, TURN BREAKER OFF AND MARK"SPARE".
9. OWNER TO REMOVE EXISTING PROJECTIONEQUIPMENT PRIOR TO CONTRACTOR DEMOLITION.
N
DEMOLITION ABBREVIATIONS:
XR - EXISTING TO BE REMOVED
XRL - EXISTING RELOCATED
XRR - EXISTING REMOVE AND RELOCATE
EX - EXISTING TO REMAIN
REVISIONS
1 2 3 4 5 6
8 97
H
G
F
E
D
C
B
A
SEE SHEET E2.2 THIS AREA
CYBERSECURITY LAB219
CYBER LOUNGE218
EXIST. CORRIDOR211
EXISTING CORRIDOR231
AIRLOCK233
EXIST. CORRIDOR207
LR6E
LR6E
LZ5 LZ5E LZ5 LZ5E
LR6 LR6
LR6
LR6 LR6E
LZ5
LZ5E
LZ5
LZ5ELR6
LR6
LR6
XAP
LR6
LZ5E
LZ5E
LR6
LR6
LR6
LR6
LZ5E
LZ5E LZ5
LR6 LR6
LZ5E LZ5 LZ5E
LR6
LZ5
LZ5E
LZ5
LZ5 LZ5 LZ5E
LZ5LZ5LZ5
XBP
XAP
XAP
XBP
XBP XAP
2 TYP
2 TYP
2 TYP
2 TYP
XAP
XBP
XAP
XAP
XAP
NL
NL
NLNLNL
NL
NL
NL
NL
NL
NLNL
NL
NL
NL
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:4
7 P
M
E2.1
OV
ER
ALL
SE
CO
ND
FLO
OR
PLA
N -
LIG
HT
ING
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
C.SHELTON
2020-02-25
FPA#07519
A.YORK
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
SCALE: 1/8" = 1'-0"E2.1
1 OVERALL SECOND FLOOR PLAN - LIGHTING
KEY PLAN
GENERAL NOTES
PLAN NOTES
A. REFER TO ARCHITECTURAL REFLECTED CEILINGPLANS FOR EXACT LOCATION OF ALL LIGHTINGFIXTURES UNLESS NOTED OTHERWISE.
B. REFER TO THE LUMINAIRE SCHEDULE LOCATED ONTHE ELECTRICAL GENERAL INFORMATION DRAWING.
C. ALL ELECTRICAL DEVICES INDICATED ON THIS PLANSHALL BE NEW UNLESS NOTED OTHERWISE.
D. LIGHT SWITCHES SHALL BE GROUPED UNDER ONECOMMON FACEPLATE WHERE MORE THAN ONE LIGHTSWITCH IS INDICATED TO BE INSTALLED AT THE SAMELOCATION.
E. ALL EXISTING LIGHTING INDICATED TO REMAIN SHALLBE RELAMPED AND CLEANED. REPAIR EXISTINGFIXTURES THAT ARE MALFUNCTIONING WHEREFEASIBLE. OTHERWISE REPLACE WITH NEW. REVISECIRCUITING AS INDICATED.
F. ALL LIGHTING BRANCH CIRCUIT WIRING ASSOCIATEDWITH NEW LIGHTING SHALL BE 2#12, 1#12GND IN 3/4"CUNLESS NOTED OTHERWISE.
G. ALL EXISTING EQUIPMENT/DEVICES NOTSPECIFICALLY INDICATED TO BE DEMOLISHED SHALLREMAIN OPERATIONAL. REVISE EXISTING CIRCUITINGTO MAINTAIN OPERATION TO SUCHEQUIPMENT/DEVICES AS REQUIRED.
H. REUSE THE EXISTING BRANCH CIRCUIT CONDUIT ANDWIRING ASSOCIATED WITH THE LIGHTING FIXTURESREMOVED DURING DEMOLITION TO REFEED NEWLIGHTING FIXTURES UNLESS NOTED OTHERWISE.REWORK THE EXISTING CIRCUIT TO PROVIDELIGHTING CONTROL AS INDICATED ON THIS DRAWING,UNLESS NOTED OTHERWISE.
I. ALL EXISTING LIGHTING INDICATED AS TO REMAINAND LOCATED IN AREAS WHERE THE CEILING ISBEING MODIFIED SHALL BE TEMPORARILYSUPPORTED AND REINSTALLED UPON COMPLETIONOF CEILING REVISIONS. COORDINATE WITHARCHITECTURAL REFLECTED CEILING PLANS ANDARCHITECTURAL TRADE.
J. ALL NIGHT LIGHT AND EXIT SIGNS SHALL BEUNCONTROLLED AND CONNECTED AHEAD OF THELOCAL LIGHTING CONTROLS.
K. ALL CONDUITS INSTALLED IN FINISHED AREAS SHALLBE ROUTED CONCEALED UNLESS NOTEDOTHERWISE.
L. ALL NOTES ADDED WILL APPEAR ON ALL DRAWINGSTHAT ARE OF THIS TYPE. NUMBERS WILL ALSO BETHE SAME TO PROMOTE CONSISTENCY.
1. PROVIDE CONTINUOUS DIMMING CONTROL VIAREMOTE DAYLIGHTING SENSOR(S) PER ASHRAE 90.12010 FOR LIGHT FIXTURES LOCATED IN THE PRIMARYSIDELIGHTED AREA. DAYLIGHT CONTROLLEDFIXTURES LOCATED IN THE PRIMARY SIDELIGHTEDAREA SHALL BE SEPARATELY CONTROLLED FROMFIXTURES LOCATED IN THE SECONDARYSIDELIGHTED AREA, AS CONTROLS INDICATE ONPLAN. ALL LIGHT FIXTURES WITHIN SPACE SHALL BECONTROLLED VIA VACNANCY SENSOR(S) WITHIN THESAME SPACE. PROVIDE ADEQUATE COVERAGE OFSENSORS AS RECOMMENDED BY THEMANUFACTURER FOR THE SPACE, REGARDLESS OFQUANTITY INICATED ON DRAWINGS.
2. CIRCUIT NEW LIGHTING INTO EXISTING CIRCUIT MADEAVAILABLE FROM DEMOLITION. EMERGENCY EGRESSAND EXIT SIGNAGE SHALL MAINTAIN ALWAYS ONOPERATION ON LIFE SAFETY CIRCUIT, TYPICAL.EXISTING SWITCHING CONTROL LOCATION TOREMAIN, SEE DEMOLITION SHEET.
3. PROVIDE REMOTE IR LIGHTING CONTROL HAND-HELDDEVICES FOR DUPLICATION OF GRAPHIC EYEPRESETS.
4. SEE LIGHTING RISER DIAGRAM ON SHEET E0.2 FORCIRCUIT NUMBERS
5. VACANCY SENSORS TIED TO ROOM CONTROLLER(GRAPHIC EYE). IF NO MOTION AFTER SET TIMEFLOOR RECEPTACLES IN THIS ROOM SHUT OFF.
NREVISIONS
VS
VS
VS
VS
VS
VS
8
8
9
9
7
7
C C
B B
A A
LZ4 LZ4
LZ4 LZ4 LZ4 LZ4 LZ4 LZ4
LZ4 LZ4 LZ4
LZ4 LZ4 LZ4 LZ4
LZ4
LZ4E LZ4 LZ4E
LZ4E LZ4E
LZ4E
LZ4E
b b b b
b
b
cd
dd
adab
b d d
dadc
da
XCP
XCP
1
SEE SHEET E2.1 FOR WORK IN THIS AREA
CP
CP
XRL XRL
V
GRAPHIC EYECONTROL UNIT
GRAPHIC EYE"SEETOUCH"
3
CP
GRAPHIC EYE"SEETOUCH"(SHADE CONTROL)
(1)
RP-2C
(32,34)
(28,30)
(1) (1) (1) (1) (1)
(1) (1)
(1)
(1)(1)(1)(1)(1)(1)
(1) (1) (1) (1) (1)
(1)(1)(1)(1)
(5) (5)
(1)
(1)
B
B
B
B
B
B
5
5
5
5
5
5
NL NL
NL
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:4
9 P
M
E2.2
PA
RT
IAL
SE
CO
ND
FLO
OR
PLA
N -
LIG
HT
ING
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
C.SHELTON
2020-02-25
FPA#07519
A.YORK
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
PLAN NOTES
1. PROVIDE CONTINUOUS DIMMING CONTROL VIAREMOTE DAYLIGHTING SENSOR(S) PER ASHRAE 90.12010 FOR LIGHT FIXTURES LOCATED IN THE PRIMARYSIDELIGHTED AREA. DAYLIGHT CONTROLLEDFIXTURES LOCATED IN THE PRIMARY SIDELIGHTEDAREA SHALL BE SEPARATELY CONTROLLED FROMFIXTURES LOCATED IN THE SECONDARYSIDELIGHTED AREA, AS CONTROLS INDICATE ONPLAN. ALL LIGHT FIXTURES WITHIN SPACE SHALL BECONTROLLED VIA VACNANCY SENSOR(S) WITHIN THESAME SPACE. PROVIDE ADEQUATE COVERAGE OFSENSORS AS RECOMMENDED BY THEMANUFACTURER FOR THE SPACE, REGARDLESS OFQUANTITY INICATED ON DRAWINGS.
2. CIRCUIT NEW LIGHTING INTO EXISTING CIRCUIT MADEAVAILABLE FROM DEMOLITION. EMERGENCY EGRESSAND EXIT SIGNAGE SHALL MAINTAIN ALWAYS ONOPERATION ON LIFE SAFETY CIRCUIT, TYPICAL.EXISTING SWITCHING CONTROL LOCATION TOREMAIN, SEE DEMOLITION SHEET.
3. PROVIDE REMOTE IR LIGHTING CONTROL HAND-HELDDEVICES FOR DUPLICATION OF GRAPHIC EYEPRESETS.
4. SEE LIGHTING RISER DIAGRAM ON SHEET E0.2 FORCIRCUIT NUMBERS
5. VACANCY SENSORS TIED TO ROOM CONTROLLER(GRAPHIC EYE). IF NO MOTION AFTER SET TIMEFLOOR RECEPTACLES IN THIS ROOM SHUT OFF.
SCALE: 1/4" = 1'-0"E2.2
1 PARTIAL SECOND FLOOR PLAN - LIGHTING
A. REFER TO ARCHITECTURAL REFLECTED CEILINGPLANS FOR EXACT LOCATION OF ALL LIGHTINGFIXTURES UNLESS NOTED OTHERWISE.
B. REFER TO THE LUMINAIRE SCHEDULE LOCATED ONTHE ELECTRICAL GENERAL INFORMATION DRAWING.
C. ALL ELECTRICAL DEVICES INDICATED ON THIS PLANSHALL BE NEW UNLESS NOTED OTHERWISE.
D. LIGHT SWITCHES SHALL BE GROUPED UNDER ONECOMMON FACEPLATE WHERE MORE THAN ONE LIGHTSWITCH IS INDICATED TO BE INSTALLED AT THE SAMELOCATION.
E. ALL EXISTING LIGHTING INDICATED TO REMAIN SHALLBE RELAMPED AND CLEANED. REPAIR EXISTINGFIXTURES THAT ARE MALFUNCTIONING WHEREFEASIBLE. OTHERWISE REPLACE WITH NEW. REVISECIRCUITING AS INDICATED.
F. ALL LIGHTING BRANCH CIRCUIT WIRING ASSOCIATEDWITH NEW LIGHTING SHALL BE 2#12, 1#12GND IN 3/4"CUNLESS NOTED OTHERWISE.
G. ALL EXISTING EQUIPMENT/DEVICES NOTSPECIFICALLY INDICATED TO BE DEMOLISHED SHALLREMAIN OPERATIONAL. REVISE EXISTING CIRCUITINGTO MAINTAIN OPERATION TO SUCHEQUIPMENT/DEVICES AS REQUIRED.
H. REUSE THE EXISTING BRANCH CIRCUIT CONDUIT ANDWIRING ASSOCIATED WITH THE LIGHTING FIXTURESREMOVED DURING DEMOLITION TO REFEED NEWLIGHTING FIXTURES UNLESS NOTED OTHERWISE.REWORK THE EXISTING CIRCUIT TO PROVIDELIGHTING CONTROL AS INDICATED ON THIS DRAWING,UNLESS NOTED OTHERWISE.
I. ALL EXISTING LIGHTING INDICATED AS TO REMAINAND LOCATED IN AREAS WHERE THE CEILING ISBEING MODIFIED SHALL BE TEMPORARILYSUPPORTED AND REINSTALLED UPON COMPLETIONOF CEILING REVISIONS. COORDINATE WITHARCHITECTURAL REFLECTED CEILING PLANS ANDARCHITECTURAL TRADE.
J. ALL NIGHT LIGHT AND EXIT SIGNS SHALL BEUNCONTROLLED AND CONNECTED AHEAD OF THELOCAL LIGHTING CONTROLS.
K. ALL CONDUITS INSTALLED IN FINISHED AREAS SHALLBE ROUTED CONCEALED UNLESS NOTEDOTHERWISE.
L. ALL NOTES ADDED WILL APPEAR ON ALL DRAWINGSTHAT ARE OF THIS TYPE. NUMBERS WILL ALSO BETHE SAME TO PROMOTE CONSISTENCY.
GENERAL NOTES
KEY PLAN
N
REVISIONS
J
J
FB
2
FB
2F
B2
FB2
FB
2
FB
2
FB2
FB2
8
8
9
9
7
7
C C
B B
A A
LAB SUPPORT217
EXIST. CLASSROOM220
STAIRS219
CYBERSECURITY LAB219
CYBER LOUNGE218
1
1
TV 74"
TV 74" TV 74"
DATA RACK
5-30R
2
2
2
2
2
2
2
2
TV 74"
TV 74"
RP-2C
IU-217
(39,41)
RP-2C
UON
(2) (3)(4)(5)
(5)
(5)
(5)
(6) (6)
(6)
(6)
(7)
(7)
(7)(7)
(8)
(8)
(8)
(9) (9)
(9)
(10,12)
(11,13)
(14,16)
(15,17)
(18,20)
(19,21)
(22,24)
(23,25)
(26)
(26)
EXIST. CLASSROOM232C
APPROXIMATE LOCATION OF EXISTING WESTINGHOUSE POW-R-LINE PANEL "PP-B" ON FIRST FLOOR.
(27)
EWC
5 5
5
5
6
4
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:5
1 P
M
E3.2
PA
RT
IAL
SE
CO
ND
FLO
OR
PLA
N -
PO
WE
R
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
C.SHELTON
2020-02-25
FPA#07519
A.YORK
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
SCALE: 1/4" = 1'-0"E3.2
1 PARTIAL SECOND FLOOR PLAN - POWER
GENERAL NOTES
PLAN NOTES
A. REFER TO ARCHITECTURAL FLOOR PLAN ANDELEVATIONS FOR EXACT LOCATION OF DEVICESWHERE INDICATED.
B. ALL RECEPTACLE OUTLETS SHALL BE RATED 20A.
C. ALL DISCONNECT SWITCHES SHALL BE HEAVY DUTYTYPE.
D. PROVIDE GFCI PROTECTION WHERE REQUIRED BYTHE NEC WHETHER INDICATED OR NOT.
E. ALL BRANCH CIRCUIT JUNCTION BOXES SHALL BELABELED WITH THE CIRCUITS ENCLOSED.
F. ALL BRANCH CIRCUIT WIRING SHALL BE 2#12,1#12GND IN 3/4"C UNLESS NOTED OTHERWISE.
G. ALL EXISTING EQUIPMENT/DEVICES NOTSPECIFICALLY INDICATED TO BE DEMOLISHED SHALLREMAIN OPERATIONAL. REVISE EXISTING CIRCUITINGTO MAINTAIN OPERATION TO SUCHEQUIPMENT/DEVICES AS REQUIRED.
H. ALL CONDUITS SHALL BE ROUTED CONCEALEDUNLESS NOTED OTHERWISE.
I. ALL ELECTRICAL EQUIPMENT MOUNTED ON THEFLOOR SHALL BE MOUNTED ON A 4" CONCRETEHOUSEKEEPING PAD.
J. PROVIDE ARC FAULT CIRCUIT INTERRUPTER TYPECIRCUIT BREAKERS IN DWELLING AND DORMITORYUNITS AND FOR ALL BRANCH CIRCUITS INDICATED INSECTION 210.12 OF THE NEC.
K. PROVIDE HOSPITAL GRADE RECEPTACLE OUTLETS INALL PATIENT CARE VICINITY LOCATIONS.
L. PROVIDE A METAL RACEWAY SYSTEM, METALLICCABLE ARMOR, OR SHEATH ASSEMBLY THATQUALIFIES AS AN EQUIPMENT GROUND CONDUCTORIN ACCORDANCE WITH SECTION 250.118 OF THE NECIN PATIENT CARE AREAS AS REQUIRED BY SECTION517.13 OF THE NEC. AN INSULATED EQUIPMENTGROUND CONDUCTOR SHALL BE PROVIDED INADDITION AS INDICATED IN SECTION 517.13 OF THENEC.
M. ALL NOTES ADDED WILL APPEAR ON ALL DRAWINGSTHAT ARE OF THIS TYPE. NUMBERS WILL ALSO BETHE SAME TO PROMOTE CONSISTENCY.
1. PROVIDE 120V POWER ABOVE ACCESSIBLE CEILINGFOR LOW-VOLTAGE EQUIPMENT SUCH AS CARDREADERS AND CAMERAS. COORDINATE EXACTREQUIREMENTS WITH SECURITY EQUIPMENTINSTALLER PRIOR TO ROUGH-IN.
2. DIVIDED FLOOR BOX / POKE-THRU, COMPLETE WITH(2) DUPLEX RECEPTACLES AND (2) DEDICATED 20A,120V CIRCUITS. COORDINATE EXACT LOCATION WITHEQUIPMENT INSTALLER PRIOR TO ROUGH-IN. ALLFLOOR BOX OUTLETS TIED TO ON/OFF VACANCYRELAY CONTROLLED BY LIGHTING SYSTEM. SEEPANEL SCHEDULE FOR ADDITIONAL INFORMATION.
3. THERMAL MOTOR SWITCH WITH ADJUSTIABLESETTINGS TO MATCH EQUIPMENT LOAD.
4. NEW 200A 120/208V 3PH. 4W. MAIN LUGS PANEL FEDFROM NEW 150A/3 CIRCUIT BREAKER IN EXISTINGPANEL "PP-B". 22,000 AIC RATED BREAKER. FEEDUSING 4#1/0 & 1#6(G)-2" CONDUIT.
5. EXISTING RECEPTACLES TO REMAIN ON THIS WALL.REPLACE EXISTING WALL COVER PLATES WITHSTAINLESS STEEL.
6. MAINTAIN 36 INCHES CLEAR FOR MAINTENANCE OFPANEL. PROVIDE HAZARD YELLOW FLOOR HATCHINGRECTANGLE IDENTIFYING NEC. WORKINGCLEARANCE REQUIRED.
KEY PLAN
N
REVISIONS
CR
CR
WAP WAP
TV TV
TV
TV
TV
TV
TV
TV
TV TV
TV
PBB
F
F
F
CR
TV
AOM
S
S
S S
S
S S
S
S
S
S
J
J
J
J
J
J
J J J J JJ
J
J
J
J
J
J
J
8
8
9
9
7
7
C C
B B
A A
LAB SUPPORT217
STAIRS219
CYBERSECURITY LAB219
CYBER LOUNGE218
2D 2D
4D
4D
4D
4D
4D
4D
4D
4D
4D
4D
MH=80"
MH=80"
MH=80" MH=80"MAC MAC
MH=80"
2D
2D
4D
4D
LH
LH
LH
LH
LH
RH
LH LH LH LH RHLH
LH
LH
LH
LH
LH
LH
LH
KEYSTONE JACK AND PATCH CORD
10' OF CATEGORY 6ACABLE COILED
TILE BRIDGE
WAPPROVIDED AND INSTALLED BY OWNER
CEILING
5'MAX.
J HOOK
AF
F
ELECTRICALSERVICEGROUND
CONDUITS
RACK/CABINET
EQUIPMENT
BUILDINGENTRANCEPROTECTION
SPLICE TRAY GROUND
CABLE TRAY
#6 AWG (100 FEET MAX)
#6 AWG
#6 AWG
#6 AWG
#6 AWG
#6 AWG
#2/0 (30 FEET MAX)
#2/0 (30 FEET MAX)
#6 AWG (100 FEET MAX)
BUILDING STEEL
BUILDINGGROUND LOOP
PBB
18"
#2/O TBB
PROVIDE FIRE RATEDPLYWOOD PAINT TO MATCHROOM WITH FIRE RATED PAINT
TGB
(4) 2" CONDUITS TO FLOOR BELOW
PROVIDE CONDUIT BUSHINGS ON ALL OPEN CONDUIT ENDS
FIRESTOP ALL PENETRATIONSFIRE STOPPING SHALL MATCH WALL/FLOOR RATING
48"
UNSECURED SIDE DOOR ELEVATION
JUNCTION BOX AS REQUIRED
CEILING
SINGLE GANG BACK BOX
FOR RTM (CENTER
ABOVE DOOR)
EXTEND CONDUIT TO
FRAME FOR MAGNETIC
DOOR CONTACT
SECURED SIDE DOOR ELEVATION
SINGLE GANG BACK
BOX FOR CARD
READER
FINISHED FLOOR
OR GRADE
EXTEND CONDUIT DOWN
INSIDE DOOR FRAME FOR
ELECTRIC STRIKE
3/4" CONCEALED
CONDUIT (TYPICAL)
CEILING
CONTRACTORS TO ENSURE
THAT THE FIRE RATING FOR ALL
DOORS AND WALLS IS MAINTAINED.
INSTALL POWER
TRANSFER HINGE IF REX
CONTACTS ARE
PROVIDED IN EXIT DEVICE
OR IF ELECTRIC LOCK IS
PROVIDED IN THE
HANDSET
303 Williams Ave. SW, Suite 1211Huntsville, AL 35801T. (256) 534-2353
SSOE, Inc.®
MEMBER OF THE AMERICAN
INSTITUTE OF ARCHITECTS
This document is a copyright protected instrument of service and
licnesed for use in the titled project only. This drawing may not be reproduced in whole or in part without written permission of
FUQUA & PARTNERS ARCHITECTS, P.C.A Professional Corporation
DATE:
ISSUE:
DRAWN:
PROJECT NO:
SHEET
OF
Architecture
Interior Design
Media Visualization
Master Planning
100 Church Street, Suite 700Huntsville, Alabama 35801
PH: (256) 534.3516FX: (256) 533.4605
www.fuquaarchitects.com
CHECKED:
2/2
1/2
020 5
:17:5
3 P
M
E4.2
PA
RT
IAL
SE
CO
ND
FLO
OR
PLA
N -
TE
CH
NO
LOG
Y
301
SP
AR
KM
AN
DR
IVE
, HU
NT
SV
ILLE
, AL
3589
9
J. ROOSEN
2020-02-25
FPA#07519
E. BAKER
CONSTRUCTION SET
UA
H B
AB
CY
BE
R L
AB
/ IN
TE
RIO
R R
EN
OV
AT
ION
SSOE #020-00457-00
SCALE: 1/4" = 1'-0"
PARTIAL SECOND FLOOR PLAN - TECHNOLOGYN
A. THE CONTRACTOR SHALL INSTALL ALL CABLE IN APROFESSIONAL MANNER. CARE MUST BE GIVEN INTHE ROUTING OF THE CABLE SO AS TO PROVIDECLEARANCE TO ALLOW THE SERVICING OF OTHERELECTRICAL CONDUITS, EQUIPMENT, LIGHTS, ETC.
B. THE CONTRACTOR SHALL FURNISH ALL LABOR,SERVICES, AND MATERIALS NECESSARY TO INSTALLA COMPLETE, FUNCTIONAL CODE COMPLINAT, ANDOWNER APPROVED SYSTEM.
C. MINIMUM CONDUIT SIZE ALLOWABLE SHALL BE 1"UNLESS NOTED OTHERWISE. WIRE SIZE SHALL BEINCREASED AS REQUIRED TO PREVENT A VOLTAGEDROP EXCEEDING 18%. CONDUIT SIZE SHALL BEINCREASED AS REQUIRED TO MEET NECREQUIREMENTS.
D. CONTRACTOR SHALL COORDINATE AND VERIFYACTUAL EQUIPMENT SIZES WITH SIZES SHOWN ONPLANS. THE CONTRACTOR SHALL BE RESPONSIBLEFOR COORDINATING SPACE ALLOCATION WITHOTHER EQUIPMENT, EQUIPMENT ORIENTATION ANDFLOOR AND WALL.
E. VERTICALLY ALIGN DEVICES INSTALLED ON WALLWITH OTHER EQUIPMENT (THERMOSTATS, LIGHTSWITCHES, CARD READERS, MANUAL PULL STATIONS,ETC.) WHERE APPLICABLE. MAINTAIN PROPERMOUNTING HEIGHT AND LOCATION OF DEVICES TOMEET CODE.
F. COORDINATE THE EXACT LOCATION OF ALL FLOORBOXES WITH THE FINAL FURNITURE LAYOUTDRAWINGS AND ARCHITECTURAL TRADE.
G. CONTRACTOR SHALL BE RESPONSIBLE FOR ALLFEES, PERMITS, AND LICENSES FOR THE COMPLETEINSTALLATION OF HIS/HER WORK.
H. COORDINATE EXACT PHASING AND SEQUENCING OFALL WORK WITH PROJECT TECHNICAL LEADER ANDTHE OWNER.
I. ALL CABLES NOT CONCEALED IN A RACEWAYROUTED IN CEILING SPACE SHALL BE PLENUM RATEDPER NEC REQUIREMENTS.
J. ALL HORIZONTAL AND VERTICAL PENETRATIONSTHROUGH FIRE RATED STRUCTURE MUST BESLEEVED (RGS CONDUIT) AND SEALED WITH ANAPPROVED FIRE STOP.
K. ALL OUTLET BOXES INSTALLED BACK-TO-BACK INWALLS SHALL HAVE FIREPROOF SOUND INSULATINGMATERIALS INSTALLED BETWEEN THE BOXES TOPREVENT SOUND TRANSMISSION FROM ONE ROOMTO ANOTHER.
L. MISCELLANEOUS SUPPORT STEEL SHALL BE THERESPONSIBILITY OF THIS CONTRACTOR. PROVIDEFLOOR MOUNTING SUPPORT RACK FOR CONDUITSRUN BETWEEN THE EQUIPMENT AND VERTICALDROPS FROM OVERHEAD OR BUSWAY. DO NOT RUNCONDUITS ON THE FLOOR.
M. ELECTRICAL EQUIPMENT SHALL BE UL LISTED ANDLABELED.
N. CENTER ALL CEILING MOUNTED DEVICES IN THECENTER TITLE WHERE APPLICABLE.
O. CONTRACTOR TO PROVIDE AND INSTALL J-HOOKS TOSUPPORT ALL CABLING IN CEILING SPACES WHERECABLE TRAY IS NOT PRESENT. SPACING SHALL NOTEXCEED 5'-0" ON CENTER.
1. POWERED FURNITURE.
2. CONTRACTOR SHALL TIE ALL CAMERAS BACK INTOTHE EXISTING SITE AVIGILON VMS.
3. (4) FOUR 2" CONDUIT STUB UPS THROUGH SECONDFLOOR. BACKBOARD TO BE FIRE RATED PLYWOODWITH VERTICAL CABLE STRAPS. COORDINATE STUBUPS WITH ARCHITECT AND BEAM LOCATIONSBELOW.
4. MIDDLE ATLANTIC ERK CABINET. TERMINATE UAHNETWORK CABLING ON NEW PATCH PANELS ANDTEST. STP CABLING SHALL NOT BE TERMINATED ONPATCH PANEL AND SHALL HAVE 10' OF SPARE SLACKAT RACK. COORDINATE WITH AV CONSULTANT.
5. HORIZONTAL LADDER TRAY MH=7'-6".
6. CHIEF XCMIU. CEILING MOUNT DROP POLE BY AVCONSULTANT. COIL 10' OF NETWORK CABLINGABOVE CEILING.
7. STUB SPARE 1" CONDUIT WITH NYLON PULL STRINGBELOW CEILING FOR FUTURE DATA CABLING.
8. NEW FIRE ALARM DEVICES SHALL TIE TO EXISTINGSIMPLEXGRINNELL 4010 PANEL BUILDING FIREALARM SYSTEM. PANEL LOCATED IN MECHANICALROOM ON FIRST FLOOR.
9. LEGRAND 8ATC2PAA FLOOR BOX. COORDINATE WITHPOWER PLANS FOR RECEPTACLE LAYOUT.
10. RELAY MODULE SHUT DOWN AHU IN GENERALALARM CONDITION.
11. CHIEF PF2UB DUAL SCREEN FLOOR STAND BY AVCONSULTANT. FEED THROUGH FLOORBOX.
12. CEILING SPEAKERS SHOWN IN CEILING GRID FORREFERENCE ONLY. CABLING, AMPLIFIERS AND A/VSYSTEM BY OTHERS. AUDIO SYSTEM SPEAKERS ON10FT. x 12FT. GRID. MAINTAIN SPACING WITH LIGHTS,CEILING DIFFUSERS, AND OTHER DEVICES.
13. POWERED ROLLER SHADES BY LUTRON.LIGHTING/SHADING SYSTEM CONTROL VIA GRAFIKEYE. PROVIDE NECESSARY WIRING FOR COMPLETESYSTEM INSTALLATION. LH = LEFT HAND SIDE FEED.RH = RIGHT HAND SIDE FEED.
GENERAL NOTES PLAN NOTES
1 (TYPICAL)
2 (TYPICAL)
3
4
5
11
7
8 (TYPICAL)
6
6
KEY PLAN
6
6 6
6
6
11
11
11
11
10
2E4.2
2E4.2
2E4.2
1
E4.2
3
E4.2
SCALE: NOT TO SCALE
1 WIRELESS ACCESS POINT DETAIL
SCALE: NOT TO SCALE
3 DATA ROOM BACKBOARD DETAILSCALE: NOT TO SCALE
2 DOOR DETAILE4.2E4.2
E4.2
11
REVISIONS
12 (TYPICAL)