ZXSS10 SS1bSoftSwitch Control EquipmentData Configuration Guide

SG Interconenction

Version 2.0.1.07

ZTE CORPORATIONNO. 55, Hi-tech Road South, ShenZhen, P.R.ChinaPostcode: 518057Tel: (86) 755 26771900Fax: (86) 755 26770801URL: http://ensupport.zte.com.cnE-mail: [email protected]

Page 2: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

LEGAL INFORMATION

Copyright © 2010 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution ofthis document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO-RATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATIONor of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are dis-claimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-in-fringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on theinformation contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subjectmatter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,the user of this document shall not acquire any license to the subject matter herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.

Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.

The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

R1.0 2010–07-15 First edition

Serial Number: SJ-20100630164932-010

Page 3: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Contents

About This Manual............................................. I

Declaration of RoHS Compliance ....................... I

SG Interconnection Configuration .....................1Configuration Overview ................................................... 1

Interconnection Data Planning.......................................... 4

Adding an SG Zone......................................................... 5

Configuring SG Maximum Capacity.................................... 7

Configuring a Zone on a Processing Board.........................11

Adding an SG Node........................................................12

Configuring an SG Group in the Same Office Direction .........14

Configuring the Office Direction of an Adjacent Switch

(CO) ....................................................................17

SCTP Configuration ........................................................21

SCTP Protocol Configuration Principle ...........................21

Configuring SCTP Common Data..................................23

Configuring SCTP Ports...............................................25

Configuring an SCTP Connection..................................27

Activating M3UA ........................................................28

Activating IUA...........................................................30

Configuring an SCTP Connection Application

Server..............................................................31

Configuring the Link Relations between UA Link and

AS...................................................................33

Configuring an Application Server ................................33

Checking Interconnection ...............................................35

Figures ............................................................37

Tables .............................................................39

Glossary ..........................................................41

Confidential and Proprietary Information of ZTE CORPORATION I

Page 4: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

This page is intentionally blank.

II Confidential and Proprietary Information of ZTE CORPORATION

Page 5: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

About This Manual

Purpose At first, thank you for choosing ZXSS10 SS1b of ZTE Corporation!

ZXSS10 SS1b is fully compatible with the layered standard NGNmodel. It can provide NGN with service call and connection con-trol functions which are required by real-time services. By usingZXSS10 SS1b, operators can provide users with many kinds ofmultimedia services which involve voice, video and data. ZXSS10SS1b is, therefore, the core of NGN in terms of call and control.

This manual describes the detailed method to interconnect ZXSS10SS1b with the Signaling Gateway (SG) devices and provides userswith guides to configure the system.

IntendedAudience

This manual is intended for

� Configuration engineers

� Equipment installation engineers

� Maintenance engineers

Prerequisite Skilland Knowledge

To use this document effectively, users should have a general un-derstanding of SoftSwitch system.

What Is in ThisManual

This manual contains the following chapters:

Chapter Summary

Chapter 1, SG InterconnectionConfiguration

It introduces SG InterconnectionConfiguration

Conventions ZTE documents employ the following typographical conventions.

Typeface Meaning

Italics References to other Manuals and documents.

“Quotes” Links on screens.

Bold Menus, menu options, function names, input fields,radio button names, check boxes, drop-down lists,dialog box names, window names.

CAPS Keys on the keyboard and buttons on screens andcompany name.

Note: Provides additional information about a certaintopic.

Checkpoint: Indicates that a particular step needs tobe checked before proceeding further.

Tip: Indicates a suggestion or hint to make thingseasier or more productive for the reader.

Confidential and Proprietary Information of ZTE CORPORATION I

Page 6: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Mouse operation conventions are listed as follows:

Typeface Meaning

Click Refers to clicking the primary mouse button (usually theleft mouse button) once.

Double-click

Refers to quickly clicking the primary mouse button(usually the left mouse button) twice.

Right-click Refers to clicking the secondary mouse button (usuallythe right mouse button) once.

II Confidential and Proprietary Information of ZTE CORPORATION

Page 7: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Declaration of RoHSCompliance

To minimize the environmental impact and take more responsibil-ity to the earth we live, this document shall serve as formal dec-laration that ZXSS10 SS1b manufactured by ZTE CORPORATIONare in compliance with the Directive 2002/95/EC of the EuropeanParliament - RoHS (Restriction of Hazardous Substances) with re-spect to the following substances:

� Lead (Pb)

� Mercury (Hg)

� Cadmium (Cd)

� Hexavalent Chromium (Cr (VI))

� PolyBrominated Biphenyls (PBB’s)

� PolyBrominated Diphenyl Ethers (PBDE’s)

The ZXSS10 SS1b manufactured by ZTE CORPORATION meetthe requirements of EU 2002/95/EC; however, some assembliesare customized to client specifications. Addition of specialized,customer-specified materials or processes which do not meet therequirements of EU 2002/95/EC may negate RoHS compliance of theassembly. To guarantee compliance of the assembly, the need forcompliant product must be communicated to ZTE CORPORATION inwritten form. This declaration is issued based on our current levelof knowledge. Since conditions of use are outside our control, ZTECORPORATION makes no warranties, express or implied, and assumesno liability in connection with the use of this information.

Confidential and Proprietary Information of ZTE CORPORATION I

Page 8: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

This page is intentionally blank.

II Confidential and Proprietary Information of ZTE CORPORATION

Page 9: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

C h a p t e r 1

SG InterconnectionConfiguration

Table of ContentsConfiguration Overview ....................................................... 1Interconnection Data Planning.............................................. 4Adding an SG Zone............................................................. 5Configuring SG Maximum Capacity ....................................... 7Configuring a Zone on a Processing Board.............................11Adding an SG Node............................................................12Configuring an SG Group in the Same Office Direction ............14Configuring the Office Direction of an Adjacent Switch(CO) ................................................................................17SCTP Configuration............................................................21Checking Interconnection ...................................................35

Configuration OverviewBackground 1. As a signaling agent, Signaling Gateway (SG) acts as a bridge

to interconnect SS7 networks with IP networks. Thus the PSTNoffice can interconnect with SS1b through SS7. It also con-verts TDM into IP and vice versa. Both I704 and MSG 9000can provide functions of a signaling gateway. Figure 1 showsthe position of SG in NGN and the protocols used in the inter-connection.

Confidential and Proprietary Information of ZTE CORPORATION 1

Page 10: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

FIGURE 1 POSITION OF SG IN NGN

2. SIGTRAN protocol cluster is used between SS1b and signalinggateways. SIGTRAN consists of two layers: the transmissionlayer and the UA layer, as shown in Figure 2.

FIGURE 2 SIGTRAN STRUCTURE

� Transmission layer: Stream control transmission protocol,or SCTP in short, provides reliable message packet trans-mission in IP networks. Located in the same layer withTCP and UDP, SCTP is a kind of reliable connection-orientedtransmission protocol. It is designed for transmitting PSTNsignaling messages in IP networks.

� UA layer: It adapts all protocols in protocol hierarchicalstructure of SCN signaling and is responsible for primitivetransmission between two layers in SCN and IP. M3UA isthe level-3 adaptation layer protocol of MTP. SS7 network

2 Confidential and Proprietary Information of ZTE CORPORATION

Page 11: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

extends from SCN network to IP network smoothly by thecooperation of M3UA and MTP3, which enables devices in IPnetwork to provide SS7 users with services without physicallayer, data link layer and complete network layer.

OverallConfiguration

Relations

Figure 3 shows the overall flow of ZXSS10 SS1b configuration. Inactual deployment, operators can adjust the above steps or config-uration items according to the actual situation in conformity withthe sequence of “basic data-interconnection data-service data-ap-plication data”.

FIGURE 3 ZXSS10 SS1B DATA CONFIGURATION FLOW

Caution:

Add DAS (digital analysis selector) for gateway cluster selectionbefore configuring interconnection data.

Confidential and Proprietary Information of ZTE CORPORATION 3

Page 12: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Interconnection DataPlanning

Introduction The interconnection between two different devices requires the in-formation of them. In this interconnection, SS side provides infor-mation for SG, and vice versa. The information must be preparedbefore the interconnection configuration.

Table 1 lists the SG interconnection configuration plan.

TABLE 1 DATA PLANNING

Configured items Planned value Remark

SG gateway zone number 2

SG cluster processing board No.3 processingboard is the firstchoice, then is No. 4

SG node number 8

SG IP address 10.40.40.109 Provided by SG

SG group number of thesame office direction

3

PSTN office direction 15 Provided by SG

Signaling point coding ofPSTN office direction

6-6-6 (24 digits) Provided by SG

SCTP connection number 2

SCTP connection port 5505 on SS side;2905 on SG side

Must be agreedby both parties

M3UA loading mode Replacement mode Must be agreedby both parties

SCTP route context 10 Must be agreedby both parties

AS application servernumber

1

ConfigureParameterAssociation

SS receives SS7 messages transferred by SG, which containsDPC+OPC. DPC+OPC are configured by interconnection data, andthen SS responses to SS7 by using the SIGTRAN protocol. Keyparameter association of SS interconnection configuration flow isshown in Figure 4.

4 Confidential and Proprietary Information of ZTE CORPORATION

Page 13: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

FIGURE 4 KEY PARAMETER ASSOCIATION OF SS INTERCONNECTIONCONFIGURATION FLOW

Adding an SG ZonePrerequisites � NetNumenN31 has been connected to the background data-

base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� DAS selected by SG has been established.

Context This topic describes how to add an SG zone.

A zone is a collection of the GW nodes which share the same at-tributes in some aspects. Nodes of different device types cannotcoexist in one zone. In the SS system, the data area of the pro-cessing board is allocated by zone. Configure the gateway zonein which an SG device is going to be located before adding the SGdevice.

Steps 1. Double click the SG icon on the Configure Management in-terface.

2. On the SG Zone interface, click the AddZONE icon .

The Zone Basic Property Configuration interface appears,as shown in Figure 5.

Confidential and Proprietary Information of ZTE CORPORATION 5

Page 14: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

FIGURE 5 ZONE BASIC PROPERTY CONFIGURATION

Table 2 lists the descriptions of the parameters.

TABLE 2 DESCRIPTION OF SG ZONE PARAMETERS

Field Name Description

Zone ID Add an unused zone number which cannot exceedthe allowed maximum number.

DAS

It is the DAS of the called party. The DAS herehas the lowest priority. If both an user and ahundreds group fail to be configured with a DAS,this DAS will be used.

Network Type It should be consistent with the network typeselected in SoftSwitch property configuration.

LATA The area code of the city in which the zone islocated.

OfficeLanguage Choose a language according to region.

PassingNetwork Type Select a local network type.

Incoming CallRight Template

Call right refers to that whether users can makecalls or receive calls under normal conditionand make calls or receive calls when they arein arrears. This template can be configuredon the interface Service Manage > UserModel Configuration > User TemplateConfiguration.

Caller DAS Do not set this parameter if you do not analyzethe caller number.

Zone Name The naming rule is as follows: device name_zonenumber, such as SG_1.

6 Confidential and Proprietary Information of ZTE CORPORATION

Page 15: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Field Name Description

Zone Type 9–SG by default.

ExtendedRight ModelNo.

Use the extended right model number cited byusers. This is an extension of the Incoming CallRight Template.

CallerAuthentication Authenticates the callers.

Domestic TG Valid in the configuration of TG/SG nodes,represents the domestic TG device.

InternationalTG

Valid in the configuration of TG/SG nodes,represents the international TG device.

PBX Valid in the configuration of TG/SG nodes,represents the user device.

Multi AreaCode Whether belong to a multi area code environment.

3. After configuring parameters, click the OK button to finish theconfiguration.

END OF STEPS

Configuring SG MaximumCapacity

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� DAS selected by SG has been established;

� A corresponding SPC processing board has been added.

Context This topic describes how to configure the SG maximum capacity.

� The processing board of SS1b processes calls and protocols bythe unit of zone; It is required to allocate a processing boardfor the zone before adding it.

� You do not have to add data area of SCTP and M3UA whenadding SG zone capacity because the system will allocate thecorresponding data area automatically according to the SCTPconnection data.

Steps 1. Right click the ZXSS10 icon and select Shelf Configurationfrom the shortcut menu.

2. Right click the corresponding SPC board and select Data AreaCapacity Configuration from the shortcut menu.

Confidential and Proprietary Information of ZTE CORPORATION 7

Page 16: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

3. Click the Add(A) button.

The Add Data Area Capacity Configuration interface popsup, as shown in Figure 6.

FIGURE 6 ADD DATA AREA CAPACITY CONFIGURATION

Table 3 lists the descriptions of the parameters.

TABLE 3 DESCRIPTION OF PARAMETERS IN ADD DATA CAPACITYCONFIGURATION CAPABILITY 1

Parameter Description

Max Calls For the use of handling users, calculatedaccording to 0.2 ERL for each line. The call dataarea size should be calculated by multiplying theuser capacity with 0.2. For the use of handlingtrunks, it is calculated according to 0.7 ERL foreach line, and the call data area size is acquiredby multiplying the trunk capacity with 0.7. Thatis, the call data area capacity is equal to themaximum user capacity * 0.2 plus the maximumtrunk capacity * 0.7. The average Erl is modifiedaccording to the actual conditions of differentareas.

Max Calls ofMGCP

If the data area size allotted to MGCP users is X,then the H248 data area size is also X.

Max Calls ofH248

If the data area size allotted to H248 users is X,then the H248 data area size is also X.

Max Calls ofH323

If the data area size allotted to H323 users is X,then the H323 data area size is also X.

Max Calls ofSIP

If the data area size allotted to SIP users is X,then the SIP data area size is also X.

MaxTransaction ofSIP

The data area size for the transaction layer ofSIP, which is configured according to the on-sitecondition.

8 Confidential and Proprietary Information of ZTE CORPORATION

Page 17: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Parameter Description

Max Reg. ofSIP

The registration data area size for SIP users,which is configured according to the on-sitecondition.

Max Calls ofSCM

Configured according to the ratio of IN calls(including MAP and CAP) for users. If the ratio is0.3, then Max Calls of SCM = Max Calls * 0.3.This ratio can be modified according to the actualcondition.

Max Calls ofINAP

Max Calls of SCM-Data Area for MAP-Data Areafor CAP.

Max Calls ofDSS1

If the call data area size allotted to DSS1 users isX, then the DSS1 data area size is also X.

Max Calls ofSS7

Configured according to the ratio of the calldata area for SS7 trunk groups of the zone. Ifthe ratio is 0.3, then this item is calculated bymultiplying Max Calls with *0.3.

Max SingleCircuit Callsof SS7

The SS7 single circuit data area refers to thedata area for single-circuit calls. The number ofSS7 single circuits is equal to 0.2 * the numberof total trunk circuits configured.

Percent ofMonitor DataSection in CallData Section

The ratio of the data area (for the listeningservice) to the call data area. If the listeningservice is not used, it is 0.

Max Subscribe The maximum data area for the announcementindicator service.

4. Click the Capability 2 tab. The system prompts Figure 7.

FIGURE 7 ADD DATA AREA CAPACITY CONFIGURATION CAPABILITY 2

Table 4 lists the descriptions of the parameters.

Confidential and Proprietary Information of ZTE CORPORATION 9

Page 18: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

TABLE 4 DESCRIPTION OF PARAMETERS IN ADD DATA CAPACITYCONFIGURATION CAPABILITY 2

Parameter Description

Max Multi CircuitCalls of SS7

The SS7 circuit group data area refers to thedata area for the trunk group circuits. Thenumber of SS7 circuit groups is calculatedby multiplying the number of total trunkcircuits configured with 0.25.

Max Calls of V5 If the call data area size for V5 users is X,the then V5 data area size is also X.

Max Data Area forBICC

Configured according to the ratio of calls tothe MSC through the BICC protocol. If nocalls to the MSC, it is 0.

Max Data Area forBICC CG

The data area size for BICC concurrent calls.

Max Data Area forPS

The data area for the disaster recoveryservice.

Max Data Area forMAP

The MAP data area.

Max Data Area forMTC

The data area size in the coding/decodinggateway configuration.

CS_2 CSA MaximalData Area

Used exclusively for the CS_2 service. Therecommended configuration ratio (CSA: CS:LEG) is 1:3:6.

CS_2 CS MaximalArea

Used exclusively for the CS_2 service. Therecommended configuration ratio of CSA,CS and LEG is 1:3:6.

CS_2 LEG MaximalData Area

Used exclusively for the CS_2 service. Therecommended configuration ratio (CSA: CS:LEG) is 1:3:6.

Note:

For other parameters: Fill 0 in all other data area. SG mainlyprocesses signaling processing instead of the detailed serviceslike call processing.

5. Click OK to finish the configuration.

END OF STEPS

Postrequisite After allocating the capacity of data area, reboot the correspondingSPC board according to system prompt.

10 Confidential and Proprietary Information of ZTE CORPORATION

Page 19: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Configuring a Zone on aProcessing Board

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� An SG zone has been added.

� A corresponding SPC processing board has been added.

Context This topic describes how to configure a zone on a processing board.

After configuring the data area of a zone, the processing of userservices, protocols and authentications can be made on this board.

Primary logical processing board and secondary logical process-ing board form an active and standby relation. When functioningproperly, the primary processing board processes the related dis-posals; When it malfunctions, the related disposals are switched tosecondary processing board. Therefore, there must be two boardsacting as primary and secondary boards. If there are no logicalprocessing boards which form an active/standby relation, the pro-cessing of services, protocols and authentications will be made ona board.

Steps 1. Select the added SG icon, right click it and select Zone andCard Configuration.

2. Click the Add(A) button.

The Add Zone and Card Configuration interface pops up, asshown in Figure 8.

FIGURE 8 ADD ZONE AND CARD CONFIGURATION

3. Fill in Master LSQ and Slave LSQ.

4. Click the OK button and system prompts you to reboot the SPCboard.

END OF STEPS

Confidential and Proprietary Information of ZTE CORPORATION 11

Page 20: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Adding an SG NodePrerequisites � NetNumenN31 has been connected to the background data-

base.

� You have logged in to the Configure Management interfaceof NetNumenN31.

� An SG zone has been added.

Context This topic describes how to add an SG node, including the IP ad-dress of the node, the protocol port number and the affiliated zonenumber.

Steps 1. In the SS topological view, double click the SG icon.

2. Click the Add SG button. The SG Property Configurationwindow appears as shown in Figure 9.

FIGURE 9 SG PROPERTY CONFIGURATION

Table 5 lists the descriptions of the parameters.

TABLE 5 BASIC PROPERTY OF SG NODE

Parame-ter Description

Node ID

Node ID is the unique number of the gatewaydevice. You can click the parameter blank to see theAvailable Node ID. This should be planned beforeconfiguration.

DeviceType

9–SG.

IP Address The actual IP address. Enter it according to the plan.

12 Confidential and Proprietary Information of ZTE CORPORATION

Page 21: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Parame-ter Description

DomainName

Domain name adopt “GW IP address” format, suchas [20.20.11.12].

MACAddress

If the authentication mode is MAC, this item shouldbe consistent with that of the terminal. In othercases, this item can be empty.

Zone Use the zone number the node belongs to.

Remark

The naming principle: City Name + Device TypeID + ID. The city name should be spelled in fulluppercase Chinese letters; The device type ID is thefunction type of the device in networks; ID is thenumber of the similar devices in a city, for example,NJSG1.

Port Type Select 1-UDP.

Local Port The number of the local SCTP connection port. Itshould be agreed by both parties, for example, 2944.

Peer Port The number of the peer SCTP connection port. Itshould be agreed by both parties, for example, 2944.

IPSP Whether interconnects through broadband. If yes,use IP mode to interconnect with SG device.

IP Version Select according to field IP address, IPv4 is commonchoice.

3. Click the Device Property tab. Figure 10 pops up.

FIGURE 10 DEVICE PROPERTY

Confidential and Proprietary Information of ZTE CORPORATION 13

Page 22: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

lists the descriptions of the parameters.

Parameter Description

Location Select whether this node belongs to the localsoftswitch or the disaster recovery softswitch.

LanguageModel Type

Select the language used by the node.

4. Click the OK button to finish the configuration.

END OF STEPS

Configuring an SG Group inthe Same Office Direction

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� An SG node has been added.

Context This topic describes how to configure an SG group in the sameoffice direction.

After the signaling gateway nodes have been configured, the PSTNoffice direction which connects this node should be configured. Be-fore configuring the office direction, you are required to configurethe relation between the office direction and the SG group. Inthe SS system, every PSTN office direction corresponds to an SGgroup, and every SG group can only be used in one office direction.An SG group can only contain 8 SG nodes at most which indicatesthat one office direction can connect one or several SG nodes.

Steps 1. On the Configure Management interface, select Proto-col(P) > SS7 Configuration(S) > Configure SG Group inThe Same Office(O).

The Configure SG Group in The Same Office interface popsup, as shown in Figure 11.

14 Confidential and Proprietary Information of ZTE CORPORATION

Page 23: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

FIGURE 11 CONFIGURE SG GROUP IN THE SAME OFFICE

2. Click the Add(A) button.

The Add SG Group in the Same Office interface pops up, asshown in Figure 12.

FIGURE 12 ADD SG GROUP IN THE SAME OFFICE

3. Fill in SG Group No. from number 1, here we take 3 as anexample.

4. Enter the configured SG node number in SP Gateway Node1, or click SP Gateway Node 1.

Confidential and Proprietary Information of ZTE CORPORATION 15

Page 24: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

The Gateway Query interface pops up, as shown in Figure 13.

FIGURE 13 GATEWAY QUERY

Note:

To configure SP Gateway Node N is similar to the way toconfigure SP Gateway Node 1.

5. Fill in the Policy Value.

Policy Value distinguishes the priority of gateway node. Smallvalue indicates high priority level. 1 represents the highestpriority and 0 represents no usage. Two gateway nodes withthe same priority indicate load sharing.

6. Click the OK button to finish the configuration.

END OF STEPS

16 Confidential and Proprietary Information of ZTE CORPORATION

Page 25: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Configuring the OfficeDirection of an AdjacentSwitch (CO)

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� You have configured an SG group in the same office direction.

Context This topic describes how to configure the office direction of an ad-jacent switch.

Steps 1. Double click the SG zone icon to enter the signaling office di-rection interface.

2. Click the AddCO button .

The CO Configuration interface pops up, as shown in Figure14.

FIGURE 14 CO CONFIGURATION

Table 6 lists the descriptions of the parameters.

TABLE 6 CO PARAMETERS OF AN SG OFFICE DIRECTION

Configura-tion items Description

Office ID The ID of this PSTN signaling direction in SSsystem.

Office Name Naming rule: city name + device type number +number, such as NANJINGJ10.

Confidential and Proprietary Information of ZTE CORPORATION 17

Page 26: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Configura-tion items Description

Office Code It’s recommended to keep it consistent with theoffice direction number.

SP Code The allocated signaling point code in the entirenetwork.

Region Code District code number, for example, Nanjing is 25.

SP Type There are 4 SP types: 1-SEP (node at signalingend); 2-STP (signaling transferring node); 3-STEP(node at signaling end or signaling transferringnode); 4-IP NODE (node in IP network). Select anSP type by its actual function in a network.

SG GroupIndex

Fill in SG group number in the same officedirection.

SPConnectionRelation

There are 2 types of SP connection methods:1-direct connection and 2-semi-direct connection.Choose one according to the connection modebetween signaling office and SG node.

Network Type Make it consistent with the network type in SSproperty configuration.

CCSSpecifications

Common channel protocol standards applied inthis office direction. Select 0-China standarddomestically.

OfficeLanguage

Select 2-English.

SP Code Type Select a signaling point coding mode of thisoffice direction. Generally, 0-SPC IN 24 BITS isadopted in China.

Sub-serviceField

Select 8-national network in China or select0-international network in other countries.

Hop Counter If Use is selected, the Hop Counter parameter willbe added to SS7 IAM messages.

Local OfficeSP Code

Fill in the SP code of the local SS whichinterconnects with this office direction.

Used Zone Fill in the SG zone number affiliated with thisoffice direction.

User Area It is used to identify a user area when receiving aspecial service call.

Routing Tag Route selection mode. Select 0–Route Selectionon GT or 1-Route Selection on DPC+SSN.

Local GT No. Fill the GT code used by the local office when0–Route Selection on GT is selected.

NetAppearance

Some devices need it. Click Net Appearance toconfigure the values and select a signaling codingmode.

18 Confidential and Proprietary Information of ZTE CORPORATION

Page 27: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Configura-tion items Description

CO Is BelongSS

This is not used by a traditional SS7 officedirection. When SCP and HLR need to supportdisaster recovery, this should be selected. Afterit is selected, the data of this office direction isvisible to the SS.

Multi AreaCode

Whether the office which interconnects with SS isin a multi area code environment.

Local-callOffice

Whether the office which interconnects with SS isa local call office.

National LongDistance CallOffice

Whether the office which interconnects with SS isa national long distance call office.

InternationalLong DistanceCall Office

Whether the office which interconnects with SS isan international long distance call office.

Test isRequired

If this item is selected, The system will return thevalues of Test Code in SS property configuration.Currently invalid.

Telephone Currently invalid.

In the SameArea

Whether the peer office only manages one longdistance region.

ISUP CalledNum Mark F

Whether add F to the tail of the ISUP callednumber.

HLR Office If this is selected, It is the HLR office direction.The MAP data zone will be selected.

SCP Office If this is selected, It is the SCP office direction.The INAP data zone will be selected.

AutomaticReply ACM

Whether SS makes response to IAM automaticallyand sends ACM messages to the peer end.

Send CollectCall

If this is selected, the forward call indicatorparameter of SS7 IAM messages will carry CollectCall.

Do NotProcess UCIC

If this is selected, the UCIC messages will not beresponded.

DivideOperator’sAccess Code

If this is selected, the access code will be filled inthe TNS parameter of SS7 IAM message.

Forbid Choosethe SameRoute of OneOffice

It is used when selecting a route. When this isselected, the route which is the same with theincoming trunk can not be used as the outgoingroute.

Compatiblewith WrongRedirectionInformation

If this is selected, when error occurs to theforward message carried by SS7 IAM, the errorcan be corrected automatically.

Confidential and Proprietary Information of ZTE CORPORATION 19

Page 28: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Configura-tion items Description

ISNI Function Intermediate Signaling Network Identification, orISNI in short, is defined in standard T1.118-1992of SCCP. If this is selected, the ISNI function issupported.

TranslationNode

It indicates that this office direction supports GTtranslation in SCCP. Currently invalid.

IAM(OG)ContainsGeneric Digits

Currently invalid.

Send CallerID in INF(OG)

Currently invalid.

ANM ContainConnectedNumber

Currently invalid.

IAM(OG)ContainsCalling Digits

Currently invalid.

SGM(OG)ContainsGeneric Digits

Currently invalid.

UUI Can BeContained

Currently invalid.

ConnectWithout CallerID (INC)

Currently invalid.

Fill theReservedBit of SCCPAddress with1

Currently invalid.

CON ContainsConnectedNumber

Currently invalid.

CPUCongested

If this is selected, after the protocol congestioncontrol function has been configured, the RELmessages of SS7 will carry a parameter ofcongestion level.

Indication ofTesting is

Currently invalid.

Send INP/INF(Do not sendcaller num-ber)(INC)

Currently invalid.

3. Click the OK button to finish the configuration.

END OF STEPS

20 Confidential and Proprietary Information of ZTE CORPORATION

Page 29: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

SCTP ConfigurationSCTP Protocol ConfigurationPrinciple

SCTP Introduction Figure 15 shows the SCTP association. Configure the SCTP trans-mission address before establishing an SCTP connection, whichmeans adding an SCTP port number to an IP address. Like the TCPport number, SCTP port number can be used to identify subscriberswho have a same address, for example, IP address 10.66.100.2and SCTP port number 5505 represent one transmission addresswhile 10.66.100.14 and 2905 represent another. In the same way,10.66.100.14 and 5505 represent another address.

FIGURE 15 SCTP ASSOCIATION

An SCTP connection must be established by the following steps:

1. SCTP common configuration: The default values are enough.

2. SCTP ports: They should be agreed by both parties.

3. SCTP connection: They should be agreed by both parties.

M3UA Introduc-tion

MTP3-User Adaptation Layer, or M3UA in short, provides primitivescommunication services for MTP3 subscribers in IP networks andMTP3 users on network edge. It interconnects the TDM SS7 withIP networks.

Figure 16 shows the position of M3UA. Through the cooperationof M3UA and MTP3, SS7 networks connects SCN networks to IPnetworks. As a result, devices in IP networks can provide SS7subscribers with services without having the physical layer, thedata link layer and the integrated network layer.

Confidential and Proprietary Information of ZTE CORPORATION 21

Page 30: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

FIGURE 16 POSITION OF M3UA

The position of M3UA in an NGN structural device is as shown inFigure 17.

FIGURE 17 POSITION OF M3UA IN NGN

Basic terms of M3UA:

� Application Server (AS)

A logical entity of specified-route key words, for example, ASis a virtual exchange unit which processes all the call processesog PSTN trunk within the range of DPC/OPC/CIC; If it is a vir-tual database unit, it processes the transaction identified byspecified SS7 DPC/POC/SCCP, SSN combination. AS includesa group of unique AS processes, among which one or severalprocesses are activated.

� Application Server Process (ASP)

Process instance of application server, ASP is working as anactivated or backup process of AS, for example, ASP can beMGC, IP SCP or IP HLR process. ASP contains SCTP ports andcan configure ASP to handle the signaling service of multipleAS.

� Route Context

22 Confidential and Proprietary Information of ZTE CORPORATION

Page 31: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

The unique value to identify route key word. Route contextcan be configured by management interface or route key wordprogram.

M3UA application must be realized by the follow steps:

1. Start M3UA. The loading mode should be determined by bothparties.

2. Configure the AS application server. The route context shouldbe determined by both parties.

3. Configure the relations between AS and SCTP. Decide whichSCTP bears the active AS.

Configuring SCTP Common Data

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31.

Context This topic describes how to configure SCTP common data, includ-ing protocol timer and default configurations.

Caution:

Most parameters in the SCTP common configurations can use thedefault values. If it is necessary to modify them, seek assistancefrom ZTE engineers.

Steps 1. On the Configure Management interface, select Pro-tocol(P) > SCTP Configuration(T) > SCTP CommonConfiguration(C).

2. Click the Modify(M) button on the SCTP Common Configu-ration(C) interface.

TheModify SCTP Common Configuration interface pops up,as shown in Figure 18.

Confidential and Proprietary Information of ZTE CORPORATION 23

Page 32: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

FIGURE 18 MODIFY SCTP COMMON CONFIGURATION

Table 7 lists the descriptions of the parameters.

TABLE 7 DESCRIPTION OF PARAMETERS IN MODIFY SCTP COMMONCONFIGURATION

Parameter Description

Min RetransmissionTime (10 ms)

The minimum time interval between sendinga Data message for the first time andsending it for the second time when the peerend sends no reply. By default, it is 100.

Max Retransmis-sion Time (10 ms)

The maximum time interval between sendinga Data message for the first time andsending it for the second time when the peerend sends no reply. By default, it is 6000.

Initial Value of RTTimer (10 ms)

The resending time interval set whenestablishing a connection. By default, it is300.

Cookie Lifecycle(10 ms)

Cookie preserving time. By default, it is6000.

RetransmissionTimes

The maximum initial message resendingtimes when starting SCTP connection. Bydefault, it is 5.

Initial Value of T1Timer (10 ms)

The waiting time after sending INIT messagewhen connecting. If the waiting timeexceeds the set time, the INIT message willbe resent. By default, it is 200.

Initial Value of T2Timer (10 ms)

The waiting time after sending shutdown orshutdown ack. If the waiting time exceedsthe set time, the message will be resent. Bydefault, it is 200.

Incoming FlowCount

The maximum number of incoming flowallowed by SCTP connection. Now thenumber is 16.

System PermitMaximum SCTP

Maximum number of SCTP connection. Bydefault, it is 320.

24 Confidential and Proprietary Information of ZTE CORPORATION

Page 33: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Parameter Description

UDP Port Number The number of UDP when used by SCTP. Now9899 is used as the port number.

Assocaitions CookieFormat

Configure Cookie format. Both0–User-defined format and 1–StandardFormat are available. By default, it is1–Standard Format. Cookie format canalso be configured in SCTP connectionconfigurations. When SCTP connection cannot read its value, it will read from here.

Checksum ALG Both 0–ADLER32 and 1–CRC32C areavailable. By default, it is 1–CRC32C.Checksum ALG can also be configured inSCTP connection configurations. When SCTPconnection can not read its value, it will readfrom here.

Socket ReceivingTimes Every 10 ms

The number of socket received every 10 ms.By default, it is 7.

3. Click the OK button to finish the modification.

END OF STEPS

Configuring SCTP Ports

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� You have added a corresponding SPC logical processing boardnumber.

Context This topic describes how to configure an SCTP port number rangeof SG service.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP Port Configura-tion(P).

2. Click the Add(A) button on the SCTP Port Configuration in-terface.

The Add SCTP Port Allocation interface pops up, as shownin Figure 19.

Confidential and Proprietary Information of ZTE CORPORATION 25

Page 34: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

FIGURE 19 ADD SCTP PORT ALLOCATION

Table 8 lists the descriptions of the parameters.

TABLE 8 DESCRIPTION OF THE PARAMETERS IN ADD SCTP PORTALLOCATION

Parame-ter

Description

LSQ Enter the SPC logic processing board which need tobe configured with SCTP port range.

Start PortNo.

Enter the beginning port number used by SCTP.

End PortNo.

Enter the end port number used by SCTP.

Note:

For Start Port No. and End Port No.: Fill in the start portnumber and end port number with the number used by SCTPin the processing board. The port range of the two processingboards cannot overlap each other and the range should not betoo wide. It is enough to contain the number of the port usedby SCTP.

3. Click the OK button to finish the configuration.

END OF STEPS

26 Confidential and Proprietary Information of ZTE CORPORATION

Page 35: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Configuring an SCTP Connection

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� An SCTP port number has been configured.

Context This topic describes how to configure an SCTP connection.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP Link Configura-tion(P).

2. Click the Add(A) button.

The Add SCTP Connection interface pops up, as shown inFigure 20.

FIGURE 20 ADD SCTP CONNECTION

Table 9 lists the descriptions of the parameters.

TABLE 9 DESCRIPTION OF THE PARAMETERS IN ADD SCTP CONNECTION

Parameters Description

Link No. Generally, number the connections from onesequentially.

LSQ Logic number of the SPC board which processesSCTP connection.

RemoteConnectionEquipmentNode No.

The number of the signaling gateway node whichconnects SS1b.

Number ofConnectedInside Streams

The number of SCTP inside streams. The numberof the logic channels which can be used whenSCTP receives messages.

Confidential and Proprietary Information of ZTE CORPORATION 27

Page 36: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Parameters Description

Number ofConnectedOutsideStreams

The number of SCTP outside streams. Thenumber of the logic channels which can be usedwhen SCTP sends messages.

Max MTULength

The maximum length of a message unit.

Local Port The number of SCTP port which is on the SSside. The value must be within the range definedby the processing board and be agreed by bothparties.

Remote Port The number of SCTP port which is on the SGside. It should be agreed by both parties.

Protocol Type Low layer communication protocol. 1-UDP and2-IP are available.

User-definedUDP Port

Low layer communication protocol. 1-UDP and2-IP are available.

Local UDP Port When the protocol type is 1-UDP, ifUser-defined UDP Port is selected, user candefine Local UDP Port and Remote UDP Port.

Remote UDPPort

When the protocol type is 1-UDP, ifUser-defined UDP Port is selected, user candefine Local UDP Port and Remote UDP Port.

SCTP Timer(10 ms)

SCTP connection heartbeat testing period. It isused to test whether SCTP connection is normalor not periodically.

Max Times ofRetransmission

The maximum times of resending a data whenthe peer end makes no reply.

Cookie Format Configure the Cookie format. 0–User DefinedFormat and 1–Standard Format are available.1–Standard Format is the default format.

Check andAlgorithm

Configure Check and Algorithm. 0–ADLER32and 1–CRC32C are available. 1–CRC32C is thedefault choice.

3. Click the OK button to finish the configuration.

END OF STEPS

Activating M3UA

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31.

28 Confidential and Proprietary Information of ZTE CORPORATION

Page 37: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Context This topic describes how to enable M3UA. You can enable M3UAwhen or after adding an SCTP connection.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP Link Configura-tion(P).

2. Click the Add(A) button to enter the Add SCTP Connectioninterface.

3. Select Activate M3UA from the drop-down menu, as shownin Figure 21.

FIGURE 21 ACTIVATE M3UA

Table 10 lists the descriptions of the parameters.

TABLE 10 DESCRIPTION OF THE PARAMETERS IN ACTIVATE M3UA

Parameter Description

Re-Establish aConnection

The time interval between establishingan M3UA connection for the first andre-establishing an M3UA connection. Bydefault, it is 3000.

M3UA Load Mode Two load mode are available, namely1–Override and 2–Load-haring. It shouldbe consistent with the AS working mode.

MessageRetransmission

The time interval between sending M3UA forthe first time and resending it when the peerend makes no reply. By default, it is 3000.

M3UA Version Whether uses a new version of M3UA.

Decoding Type If Do Not Use Net Appearance is selected,choose one from 24–bit SPC and 14–bit SPC.

Server Whether the local end works as the server end.

Do Not Use NetAppearance

If this is selected, the net appearance willnot be used and thus the decoding typeitem should be configured; If it is selected,the net appearance will be used and thenet appearance should be configured inconfiguring office direction.

Confidential and Proprietary Information of ZTE CORPORATION 29

Page 38: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

4. Click the OK button to finish the configuration.

END OF STEPS

Activating IUA

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31.

Context This topic describes how to enable IUA.

As a signaling gateway, I704 uses IUA protocol. Therefore, youneed to activate IUA before establishing an SCTP connection; Ifan SCTP connection has been established, modify it to supportIUA.

Caution:

For the SPC processing board which processes I704 devices, selectcall and SCTP+IUA.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP Link Configura-tion(P).

2. Click the Add(A) button.

3. Select Activate IUA from the drop-down menu, as shown inFigure 22.

FIGURE 22 ACTIVATING IUA

Table 11 lists the descriptions of the parameters.

30 Confidential and Proprietary Information of ZTE CORPORATION

Page 39: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

TABLE 11 DESCRIPTION OF THE PARAMETERS IN ACTIVATING IUA

Parameter Description

IUA ExpectedValue

The initial status when IUA link has beenestablished. Generally, 8–link activate isselected.

IUA Load Mode Two modes are available, namely 1–Overrideand 2–Load-sharing. It should be consistentwith the one configured at the gateway side.

SupportHeartBeat

Whether support Heartbeat test. If thisis selected, IUA link status will be tested.Generally, it does not need to be configured.

Support TEI If this is selected, when channel D is established,a TEI query message will be sent. The TEIquery message can also be sent through MML.Generally, it does not need to be configured.

IUA Client orServer

It indicates whether this end is a client or aserver. If this is the client, active connectionwill be made. It should work with the PSTNside. If the PSTN side is the client, IUA shouldbe the server.

IUA DLCIFormat

Choose a DLCI coding type. When interconnectwith old ZTE devices, select 0–User DefinedFormat; When interconnect with devicesproduced by other producers or the latest ZTEgateways, select 1–Standard Format.

Threshold If Reestablish Communication WhileTimes of QPTM without Response AccessThreshold is selected, fill the threshold.

ReestablishCommunicationWhile Times ofQPTM withoutResponseAccessThreshold

Under the circumstance that the 931 messagecan only be transmitted in one way throughIUA link, if the message amount reaches thethreshold, restart the IUA link.

4. Click the OK button to finish the configuration.

END OF STEPS

Configuring an SCTP ConnectionApplication Server

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31.

Confidential and Proprietary Information of ZTE CORPORATION 31

Page 40: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

Context This topic describes how to configure an SCTP connection applica-tion server, which involves the peer node, protocols of adaptationlayer and route context.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP ApplicationServer Configuration(A).

2. Click the Add(A) button.

The Add SCTP Application Server Configuration interfacepops up, as shown in Figure 23.

FIGURE 23 ADD SCTP APPLICATION SERVER CONFIGURATION

Table 12 lists the descriptions of the parameter.

TABLE 12 DESCRIPTION OF THE PARAMETERS IN ADD SCTPAPPLICATION SERVER CONFIGURATION

Parameter Description

Applicationserver Index

Number the application servers from onesequentially.

User AdaptorType

The activated protocol adaptation type whenselecting SCTP connection configuration.

Remote SGNode ID

Fill the signaling gateway node number.

TG Node ID Fill the number of the TG node which needsservice. You can ignore it if it only interconnectswith SG.

Route Context It should correspond to the AS routing contextwhich is on the SG side and be consistent withAS routing context.

3. Click the OK button to finish this configuration.

END OF STEPS

32 Confidential and Proprietary Information of ZTE CORPORATION

Page 41: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Configuring the Link Relationsbetween UA Link and AS

Prerequisites � NetNumenN31 has been connected to the background data-base;

� You have logged in to the Configure Management interfaceof NetNumenN31;

� You have established an SCTP application server index.

Context This topic describes how to configure the SCTP application server.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP ApplicationServer Configuration(A).

2. Select a configured SCTP application server, click the Mappingtab and then the Add Mapping(U).

The Add Mapping interface pops up, as shown in Figure 24.

FIGURE 24 ADD MAPPING

3. Fill in User Adaptor Link ID which is the SCTP connectionnumber.

4. Click the OK button to finish the configuration.

END OF STEPS

Configuring an Application Server

Prerequisites � NetNumenN31 has been connected to the background data-base.

� You have logged in to the Configure Management interfaceof NetNumenN31.

� You have established an SCTP application server index.

Context This topic describes how to configure the signaling office directionand upper-layer subscriber.

Steps 1. On the Configure Management interface, select Proto-col(P) > SCTP Configuration(T) > SCTP ApplicationServer Configuration(A).

2. Click the AS Configuration(S) button and enter the AS con-figuration interface. Then click the Add(A) button.

Confidential and Proprietary Information of ZTE CORPORATION 33

Page 42: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

The Add Application Server interface pops up, as shown inFigure 25.

FIGURE 25 ADD APPLICATION SERVER

Table 13 lists the descriptions of the parameters.

TABLE 13 DESCRIPTION OF THE PARAMETERS IN ADD APPLICATIONSERVER

Parameters Description

ApplicationServer No.

Number of the configured SCTP AS.

Office ID The ID of the adjacent office direction in whichAS is located.

Start CIC The start CIC of the trunk circuit CIC rangecorresponding to AS.

End CIC The end CIC of the trunk circuit CIC rangecorresponding to AS.

ConnectedUpper-levelUser

Upper-layer bearer type, or the user type thatis supported by link.7-TUP, ISUP,SCCP User isgenerally selected, which indicates that all theupper-layer users are supported.

3. Click the OK button to finish the configuration.

END OF STEPS

34 Confidential and Proprietary Information of ZTE CORPORATION

Page 43: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Chapter 1 SG Interconnection Configuration

Checking InterconnectionPhysical Check On the NetNumenN31 management interface, right click an SS

NE and select Diagnose Management from the shortcut menu.Then select Instant Test > Net Detect on the popup interface.Finally click the Detect button. Figure 26 shows the physical con-nection.

FIGURE 26 NET DETECT

Signaling Trace Conduct signaling trace and judge whether the service interactionbetween the two parties are normal if the physical connection isperfect.

Right click an SS NE and select Protocol Tracing to enter the Sig-naling Trace interface. Conduct SCTP signaling trace and judgewhether the service interaction between the two parties are ingood condition.

The normal start flow of SCTP is shown in Figure 27.

FIGURE 27 SCTP NORMAL START FLOW

Command Mode Right click an SS NE and select Command Line Terminal to enterthe CLI Console interface. Enter command 5304:SG node num-ber to query the SG node status.If the reply contains status=AC-TIVE and officeID status is REACHABLE, it indicates that theinterconnection is in good condition.

Confidential and Proprietary Information of ZTE CORPORATION 35

Page 44: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

As shown in Figure 28, the AS status of SG has been activated andthe SS7 signaling office direction is reachable. all of these indicatethat the interconnection is perfect.

FIGURE 28 CHECKING SG INTERCONNECTION STATUS

36 Confidential and Proprietary Information of ZTE CORPORATION

Page 45: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Figures

Figure 1 Position of SG in NGN ............................................. 2

Figure 2 SIGTRAN Structure................................................. 2

Figure 3 ZXSS10 SS1b Data Configuration Flow...................... 3

Figure 4 Key Parameter Association of SS Interconnection

Configuration Flow.............................................. 5

Figure 5 Zone Basic Property Configuration ............................ 6

Figure 6 Add Data Area Capacity Configuration ....................... 8

Figure 7 Add Data Area Capacity Configuration Capability 2...... 9

Figure 8 Add Zone and Card Configuration ............................11

Figure 9 SG Property Configuration ......................................12

Figure 10 Device Property...................................................13

Figure 11 Configure SG Group in the Same Office ..................15

Figure 12 Add SG Group in the Same Office ..........................15

Figure 13 Gateway Query ...................................................16

Figure 14 CO Configuration .................................................17

Figure 15 SCTP Association.................................................21

Figure 16 Position of M3UA .................................................22

Figure 17 Position of M3UA in NGN.......................................22

Figure 18 Modify SCTP Common Configuration.......................24

Figure 19 Add SCTP Port Allocation ......................................26

Figure 20 Add SCTP Connection...........................................27

Figure 21 Activate M3UA ....................................................29

Figure 22 Activating IUA.....................................................30

Figure 23 Add SCTP Application Server Configuration .............32

Figure 24 Add Mapping.......................................................33

Figure 25 Add Application Server .........................................34

Figure 26 Net Detect..........................................................35

Figure 27 SCTP Normal Start Flow .......................................35

Figure 28 Checking SG Interconnection Status ......................36

Confidential and Proprietary Information of ZTE CORPORATION 37

Page 46: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

This page is intentionally blank.

38 Confidential and Proprietary Information of ZTE CORPORATION

Page 47: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Tables

Table 1 Data Planning ......................................................... 4

Table 2 Description of SG Zone Parameters ........................... 6

Table 3 Description of Parameters in Add Data Capacity

Configuration Capability 1.................................... 8

Table 4 Description of Parameters in Add Data Capacity

Configuration Capability 2...................................10

Table 5 Basic Property of SG Node .......................................12

Table 6 CO Parameters of an SG Office Direction....................17

Table 7 Description of Parameters in Modify SCTP Common

Configuration ....................................................24

Table 8 Description of the Parameters in Add SCTP Port

Allocation .........................................................26

Table 9 Description of the Parameters in Add SCTP

Connection .......................................................27

Table 10 Description of the Parameters in Activate M3UA ........29

Table 11 Description of the Parameters in Activating IUA.........31

Table 12 Description of the Parameters in Add SCTP

Application Server Configuration ..........................32

Table 13 Description of the Parameters in Add Application

Server..............................................................34

Confidential and Proprietary Information of ZTE CORPORATION 39

Page 48: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

This page is intentionally blank.

40 Confidential and Proprietary Information of ZTE CORPORATION

Page 49: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

Glossary

AS- Application Server

ASP- Application Service Process

CIC- CircuitIdentification Code

DPC- Destination Point Code

GW- Gate Way

HLR- Home Location Register

IP- Internet Protocol

M3UA- MTP3-User Adaptation layer protocol

MGC- Media Gateway Controller

MTP- MessageTransfer Part

MTP3- Message Transfer Part layer 3

NE- Network Element

NGN- Next Generation Network

OPC- Origination Signaling Point Code

PSTN- Public Switched Telephone Network

SCCP- Signaling Connection Control Part

SCN- Signaling Communication Network

SCTP- Stream Control Transmission Protocol

SG- Signaling Gateway

SPC- System Protocol Control (card)

SS- Soft Switch

Confidential and Proprietary Information of ZTE CORPORATION 41

Page 50: ZXSS10SS1b - donbassmedia.net.ua Technical Documents... · radiobuttonnames,checkboxes,drop-downlists, ... Parameter Association ... CS_2CSAMaximal DataArea

ZXSS10 SS1b Data Configuration Guide SG Interconenction

SS7- Signaling System No. 7

TCP- Transfer Control Protocol

TDM- Time Division Multiplexing

UDP- User Datagram Protocol

42 Confidential and Proprietary Information of ZTE CORPORATION