ZXG10-MSC/VLR,HLR/AUC,SC ZXG10-MSC/VLR,HLR/AUC,SC Software InstallationSoftware Installation
Agenda
General Installation Flow
ZXG10-MSC/VLR Software Installation
ZXG10-HLR/AUC Software Installation
ZXG10-SC Software Installation
General Installation Flow
General Installation FlowStart
Project Survey
Project Design
2nd Environment Acceptance
Unpacking&Inspection
Hardware Installation
Checkup&Power-on
Software Installation
System Test
Deliver for Acceptance Test
1st Acceptance Test
Handover
Cutover Preparation
Cutover
Trial Run
Final Acceptance
End
ZXG10-MSC/VLR Software Installation
ZXG10-MSC/VLR Software
TCP/IPTCP/IP
MPMMPM
OMM OMM ServerServer
OMM OMM ClientClient Billing Billing
ServerServer
ZXG10-MSC/VLR Software List
OMM ServerWin2000 ServerMSSQL2000 ServerZXG10-MSC/VLR OMC-Server
OMM ClientWin2000 ServerMSSQL2000 ClientZXG10-MSC/VLR OMC-Client
Billing ServerWin2000 ServerMSSQL2000 ServerZXG10-MSC/VLR OMC-Billing SystemDual-system Software
Installation of Win2000 Server Suggested Partition:
Required Components:
Install “FTP Service” on OMM Server&Client and Billing Server;
Install “RAS” on OMM Server&Client;
Install “IIS” on Billing Server;
Disk Space> 20G
C: 4G(NTFS) Win2000
D: 16G (8G for Client)
SQL Server
E: Left Space Backup files and toolsDisk Space< 20G
C: 4G(NTFS) Win2000
D: Left Space SQL Server, backup files
Installation of Win2000 Server
Raid—Redundancy Array of Independent Disks
OMM Server with RAID card and two hard disks can adopt RAID1.
Disk array of Billing Server equipped with three hard disks can adopt RAID5 mode; Disk array of Billing Server with more than four hard disks can adopt RAID0+1 mode.
Installation of Win2000 Server
ModeMode DescriptionDescription
RAID0 Make a virtual disk out of n disks. The available capacity is n disks.
Data are alternately written to these disks.No redundancy data but high read-write performance.
RAID1 Make a virtual disk out of two disks. The available capacity is 2 disks.
Data are duplicated on these two disks. Quick read but slow write. Good data redundancy.
*RAID5 Make a virtual disk out of n disks. The available capacity is n-1 disks. Data are alternately written to these disks. Quick read but slow write. Good redundancy data.
*RAID0+1 Make a virtual disk out of n disks. The available capacity is n/2 disks.
Data are copied between two mirror disks. High read-write performance and good data redundancy.
Installation of Win2000 Server Computer Name—ZX_area code_office code_node code
Area code :10~999;
Office code:1~254;
Node code : 129~133 for server,200~239 for client,240~255 reserved;
IP Address— a.b.c.d
a=192+Int{(Area code*8)/256}
b=Remainder of {(Area code*8)/256}
c=Office code
d=Node code
Note:
For servers with multiple Ethernet cards, a.b.c remain the same and 10 is
added to d for the second card, 20 for the third, and so on.
Login Account—ZXG10/ZXG10 (Administrator)
Node Code Conventions
240~245Reserved
130(131,132)Billing Server
200~239OMM Client
129OMM Server
ZXG10-MSC/VLR
Installation of MSSQL 2000
Installation of MSSQL2000 Server Tool
Set installation folder to Disk D (For Billing server and HLRDB,
set data folder to the shared disk array (M), if there is)
Use “Local System Account”
Use “Mixed Authentication Mode” and “Blank Password”
Installation of MSSQL2000 Client Tool
Installation of SP3
Installation of MSSQL 2000
Database Properties
Master—Data: 100MB
Log : 30MB
Tempdb—Data:200MB
Log :100MB
Installation of OMC-Server (1)
Installation of OMC-Server (2)
Installation of OMC-Server (3)
Installation of OMC-Server (4)
Delete node “133”
Installation of OMC-Server (5)
Installation of OMC-Server (6)
After restart
Installation of OMC-Server (7)
Installation of OMC-Server (8)
Table of Suggested Database Size
Database Name Data(MB) Log(MB)
Alarm Database 160 40
Performance Statistics DB 600 300
User Trace DB 50 20
Diagnosis and Test DB 16 None
Database Management DB 20 10
Installation of OMC-Server (9)
No CSM
MSC 2~n
VLR 2~n
With CSM
CSM 1&2
MSC 3~n
VLR 1
Installation of OMC-Client
Installation of OMC-Billing
Don’t initialize right management database.
Installation of Dual Billing Server
Dual system comprises two servers with identical configurations and a disk array.The two servers are monitored by a heartbeat cable.The two servers are in active/passive mode.The disk array can only be accessed by the active server.
Ethernet
Billing Server ADisk array
RS 232 Connection
X.25/FTAM to Billing Center
Router
Billing Server P
Installation of Dual Billing Server1. Start disk array and server A, install Win2000, SQL Server 2000 and
Billing system as 130.
2. Set “MSSQL Server” service startup type to “manual”, delete “SerApp.exe” from startup folder and then modify the IP and computer name to 131.
Note: Install SQL program on the local disk but the data to the disk array.
3. Shut down server A and start server P. Install Win2000, SQL Server 2000 and Billing system as 130. Set “MSSQL Server” service startup type to “manual”, delete “SerApp.exe” from startup folder. Then modify the IP and computer name to 132.
Note: Windows login account and password, SQL Server installation program folder, data folder and size should be identical to those of server A.
4. Start both servers, install Cluster software, establish heartbeat link and start cluster operation on both servers.
5. Setup cluster resources on the active server.
Installation of NT Cluster
Installation of NT Cluster
Installation of NT Cluster
Input the password of “administrator” account;
The current login user must be “administrator”, otherwise, system requests to restart.
Installation of NT Cluster
Post-installation of NT ClusterCluster Service –“Automatic” startup type and log on as “Local System account”;Cluster Monitor Service—“Manual” startup type and log on as “Local System account”;
Cluster Service Properties (Local Computer)
General
OK Cancel
Service name: ClusSvc
Display name: Cluster Service
Description: Enables servers to work together as a cluster to keep
Log On Recovery Dependencies
ApplyApply
StopStopStart
Path to executable:
D:\WINNT\cluster\clussvc.exe
Startup type: Automatic
Service status:
You can specify the start parameters that apply when you start the servicefrom here:
Start parameters:
PausePause ResumeResume
Cluster Service Properties (Local Computer)
General
OK Cancel
Log on as:
Log On Recovery Dependencies
Local System accountAllow service to interact with desktop
This account NWTRADERS\clustservice
Password: ***************
Confirm password: ***************
ApplyApply
You can enable or disable this service for the hardware profiles listed below.
Browse…
Hardware Profile ServiceProfile 1 Enabled
EnableEnable Disable
Started
Start Cluster
Run [StartProgramCluster ManagerCluster Administration Tool].
Input License
Select “Tools”“License”.
Input the information from license.txt and restart Cluster Manager.
Then run “Tools” “Start Cluster Operation”.
Do the same for the other server.
Start Cluster
Run [ ToolsStart Cluster Operation ] to start cluster service on two hosts.
Establish Heartbeat Link
Select[ Private NetTCP/IP Socket] .
Establish Heartbeat Link
Select[ Private NetTCP/IP Socket] and do the same on the other server.
Establish Heartbeat Link
Select[ Private NetRS-232 Serial Port ] and do the below setting on both servers.
Setup Cluster Resources
Dependency relationship between cluster resources
SerAppMa.exe
MSSQLServer
Volume
Computer AliasName
IP Address
MSSQL Agent
Only need to create resources on one server. This server will act as the active server.
Prerequisite
Volume
Select “Resource”“Create”“Volume…”
Select[ Resource][ Bring In Cluster] to bring in resource.
IP Address
Select “Resource”“Create”“IP Address…”
Alias Name
Alias Name resource provides a unified computer name to the two servers. External computers and applications access the dual system via the alias name.
Select “Resource”“Create”“Computer Alias Name…”
NT Service
For Billing server, NT Service resource includes “MSSQLServer” and “SQLServerAgent”.
Select “Resource”“Create”“NT Service…”
User Define
For Billing server, User Define resource only includes SerAppMa.exe.
Select “Resource”“Create”“User Define…”
SerAppMa.exe
SerAppMa.exe
OMM Server File DescriptionFilenameFilename DescriptionDescription
SerAppMa.exe Process management program at the background server
zxlogin.exe User logon program
winnttcp.exe MSS communication system program
Ztetool.exe Execution program of the floating toolbar
diarypro.exe Log management program at the server side
mopSrv.exe Performance statistics program at the server side
oamSrv.exe Alarm management system program of the service server at the server side
oaSev.exe Alarm management system program at the server side.
ocCli.exe Base Configuration Management program at the client side
ofCli.exe File management program
ooCli.exe Service observation program
osCli.exe Variable control program at the client side
otCli.exe Signaling trace program
ouSrv.exe User trace program at the server side
ovCli.exe Version management program at the client side
R07SVR.exe Version management program at the server side
R12.exe Diagnosis and test program
OMM Server Database Description
DatabaseDatabase DescriptionDescription
moaMssData.dat Alarm database
modbomcdata.dat Database management database
Mopdata.dat Performance statistics database
Mosdata.dat Variable control database
mouMscVlrData.dat User trace database
movMssData.dat Version management database
R12.dat Diagnosis and test database
zdb_zxj10.dat Base configuration management database
zdb_zxj10_diary.dat Log database
zdb_zxj10_mult.dat Multi-terminal configuration database
zx_right.dat Right management database
Billing Server File,Folder and DB Description
NameName DescriptionDescription
\\Ecdr \ Store error bills generated during coding bills
\\Ftam\ Store bills for the billing center to collect
\\Hotbil\ Store hot billing tickets
\\Hotftam\ Store hot billing tickets for the billing center to collect
\\ObCfg\ Store the configuration files of the bill receiving process
\\Zxgbil\ Store original bills
\\Zxgtemp\ Store the temporary bill files in the bill receiving process
MobWatch.exe Billing monitoring program at the client side
mobwSrv.exe Billing monitoring program at the server side
obSrv.exe Billing management program at the server side
obsrvr.exe Program of the billing receiving process
mobMscVlrData.dat Billing management database
ZXG10-HLR/AUC Software Installation
ZXG10-HLR/AUC Software
DATABASE SERVER
Disk Array
CPM
ServiceServer
OMM SERVEROMM Client Service
Agent Console
ZXG10-HLR/AUC Software
OMM ServerWin2000 Server;MSSQL2000 Server;ZXG10-HLR/AUC OMC Server;
OMM ClientWin2000 Server;MSSQL2000 Client; ZXG10-HLR/AUC OMC Client;
Service ServerWin2000 Server;MSSQL2000 Server; ZXG10-HLR/AUC Service Processing Software;
Database ServerWin2000 Server;MSSQL Server2000; Dual-system Software;
Node Code Conventions
ZXG10-HLR/AUC
OMM Server 129
OMM Client 200~239
Service Server 140~149
Database Server 170 (171,172)
Installation of OMC-Server
Installation of Service Processing Application
Run “Install\Hlr\HlrSetup\Hlrsetup.exe”
Installation of Database Server
Install NT Cluster and create the following resources:IP Address;
Volume;
Alias Name;
NT Service (MSSQLSERVER, MSSQLSERVER AGENT)
Installation of Remote Service Agent
201 202 203 204 205
192.200.1.201
192.200.1.202
192.200.1.203
.
.
.
ZTE HLRdatabase 170
ZTE gateway 200
Far-end service agent
TCP connection
Port No. 3000
IP address
Agent 1
Agent 2
Agent 3
ZTE Gateway detects the TCP connection of remote service agent from Port 3000.
Installation of Remote Service Agent
ZTE Gateway assigns an IP address and node code to each service
agent that wants to access HLR database.If a service agent only has one IP address (assigned by ZTE
Gateway), it requests to connect(…) ZTE Gateway Port 3000.
If a service agent has multiple IP addresses, it requests to
Bind(…) before connect(…) to Port 3000 of the gateway. The
binding IP address is the IP address assigned by the gateway.
Installation of Remote Service Agent
ZTE Gateway can be an independent server or OMM Server(129).
Example:
Area code of 129=010, Office code=1, Node code=129;
Gateway IP of the ZTE Gateway is 192.80.1.253;
Gateway IP of the other side is 120.1.1.1;
IP of remote service agent is 120.1.1.33;
Node code assigned to the service agent is 201.
Installation of Remote Service Agent
Installation Procedure1. Copy file to c:\zxg10\tcpout.exe( Communication gateway program) of 129;2. Copy file to c:\zxg10\tcpdog.exe( Communication gateway watchdog) of 12
9;3. Copy file to c:\winnt\tcpout.ini( Communication gateway config file) of 129;4. Create c:\zxg10\tcpdog.exe in the startup folder of 129;5. Create an IP 192.80.1.200 on 129;6. Create a Gateway 192.80.1.253 on 129;7. Start c:\zxg10\tcpdog.exe。
200 gateway connects to 129.The line connecting 200 gateway and 129 is green. The line connecting 200 to service agent 201 is red.Ping service agent IP 120.1.1.33. If it replies, then the configuration at our side is normal.
Tcpout.ini[Setup]
AreaCode=010
PostOffice=1
LocalNode=200
IsServer=1
IsRemote=0
ListenPort=3000
OMMServer=129
JFServer=129
OMMMp=2
ConnectOMMServer=0
ConnectJFServer=0
ConnectMP=0
AutoCheckApp=1
AutoCheckApp=1
[RemoteInfo]
Remote1=Name (omcserver), N
ode (129)
Remote2=Name (A1), Node (20
1), IP (120.1.1.33), Connect (S)
OMM Server File&DB Description
NameName DescriptionDescription
Dbiosrv.exe HLR agent management system server program
OcCli.exe Base configuration management client program
ochcli.exe HLR configuration management client program
ochsvr.exe HLR configuration management server program
MocHlrData.dat HLR configuration management database
Service Server File&Folder Description
NameName DescriptionDescription
Config Store system configuration file “S10cfg.ini”
Data Store HLR configuration data
Trace Save debugging information file debug.log and error.log
ZXG10_v1 Store HLR service server version program zxg10_hm.exe
ZXG10_v2 Used for upgrading
ZXG10_WTHDOG Store HLR service server watch dog program S10dog.exe and
the debugging output window S10see.exe
ZXG10-SC Software Installation
ZXG10-SC Software
PLMN
EmailServer
WebServer
VM …
OMM Server Service
Agent
TCP/IP
SMPP
OMM Client
Database
SS7
IW/GMSC
Information Station
SMPP Agent
Database
Billing Server
Other SME
Service Server
ZXG10-SC Software
OMM Server
Win2000 Server;
MSSQL2000 Server;
ZXG10-SC OMC Server;
OMM Client
Win2000 Server;
MSSQL2000 Client;
ZXG10-SC OMC Client;
Billing Server
Win2000 server;
MSSQL2000 Server;
ZXG10-SC Billing
System;
Dual-system Software;
Service Server
Win2000 Server;
MSSQL2000 Server;
ZXG10-SC Service Processing
Software;
Dual-system Software;
SMPP Agent Server
Win2000 Server;
MSSQL2000 Client;
ZXG10-SC SMPP Agent Soft;
Dual-system Software
Node Code Conventions
ZXG10-SC
IW/GMSC 2~63
OMM Server 129
OMM Client 200~239
Billing Server 130
Short Message Configuration 133
Service Server 140~147
SMPP Agent Server 160~167
Information Station 150~159
Web/Email 150~152
Query Server 250
Installation of OMC-Server
Installation of Dual Billing Server
Create the following cluster resources:
Volume(M)
IP Address
Alias Name
NT Service (MSSQLSERVER, SQLSERVER AGENT, FTP)
User Define (SerAppMa.exe , Cdrpick.exe )
Select driver M:
Select “Cluster System” in “Configure Cluster” window.
Copy CdrPick.exe to M: and set Post-picking folder to M:;Point FTP service folder to Post-picking folder;
Installation of Service Processing Application
Click the “Scsetup.exe” program under the “Install\Smsc\Scsetup\I386”
Create “Smscdb” and run “smscdb.sql” script under the “Install\Smsc\Config”.
Dual Service Server
Create the following cluster resources:
Volume
IP Address
NT Service (MSSQLSEVER, SQLSERVERAGENT)
Installation of SMPP Agent Application
If cluster is adopted, only “IP Address” resource is required.
Troubleshooting
1. SQL Server is not correctly installed.
Re-install SQL Server.
2. SQL Server logon user password is not correctly set.Reset password.
3. Failure of booting a database during subsystem installation.Cause: repeated installation of the same subsystem.
Solution:use Task Manager to kill the corresponding process, reboot and reinstall.
Reference
ZXG10-MSC/VLR (V3.0) Installation Manual
ZXG10-HLR/AUC(V3.0)Installation Manual
ZXG10-SC(V3.0) Installation Manual