Upload
joao-gilberto-fernandes
View
5.775
Download
866
Tags:
Embed Size (px)
Citation preview
NetNumen N31 (V4.2.0) Network Management System (General)
User Manual (Volume I)
Version 4.2.0
ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected]
LEGAL INFORMATION Copyright © 2006 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice. Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information. The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History
Date Revision No. Serial No. Reason for Issue
Feb. 10, 2007 R1.0 Sjzl20072644 First edition
ZTE CORPORATION Values Your Comments & Suggestions! Your opinion is of great value and will help us improve the quality of our product documentation and offer better services to our customers.
Please fax to (86) 755-26772236 or mail to Documentation R&D Department, ZTE CORPORATION, ZTE Plaza, A Wing, Keji Road South, Hi-Tech Industrial Park, Shenzhen, P. R. China 518057.
Thank you for your cooperation!
Document Name NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
Product Version V4.2.0 Document Revision Number R1.0
Serial No. Sjzl20072644 Equipment Installation Date
Presentation: (Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization, Appearance)
Good Fair Average Poor Bad N/A
Accessibility: (Contents, Index, Headings, Numbering, Glossary)
Good Fair Average Poor Bad N/A
Your evaluation of this documentation
Intelligibility: (Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)
Good Fair Average Poor Bad N/A
Your suggestions for improvement of this documentation
Please check the suggestions which you feel can improve this documentation: Improve the overview/introduction Make it more concise/brief
Improve the Contents Add more step-by-step procedures/tutorials
Improve the organization Add more troubleshooting information
Include more figures Make it less technical
Add more examples Add more/better quick reference aids
Add more detail Improve the index
Other suggestions
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
# Please feel free to write any comments on an attached sheet.
If you wish to be contacted regarding your comments, please complete the following:
Name Company
Postcode Address
Telephone E-mail
This page is intentionally blank.
Contents
About This Manual ............................................................ i Purpose................................................................................ i Intended Audience ................................................................. i Prerequisite Skill and Knowledge .............................................. i What Is in This Manual ........................................................... i Related Documentation.......................................................... ii Conventions......................................................................... ii How to Get in Touch............................................................. iii
Declaration of RoHS Compliance..................................... v
Chapter 1.......................................................................... 1
Installation Overview ......................................................1 Network Analysis ............................................................1 Software Requirements....................................................2 Hardware Requirements...................................................2
Single System Requirements for Windows ................................3 Single System Requirements for UNIX .....................................4 Dual System Requirements for Windows...................................6 Dual System Requirements for UNIX........................................7 Hardware Firewall .................................................................9
Chapter 2........................................................................11
Database Installation ....................................................11 Oracle Database Installation ........................................... 11
Hardware Requirements....................................................... 11 Software Requirements........................................................ 12 Installation Preparation........................................................ 13 Installing Oracle 9i .............................................................. 20 Oracle 9i Post Installation Check ........................................... 22 Configuring Database .......................................................... 23 Installing Oracle9i Service Pack............................................. 25
SQL Server Database Installation .................................... 31
Chapter 3........................................................................41
NMS Installation ............................................................41 Overview ..................................................................... 41 Installing NMS for Windows ............................................ 42
Installing NMS Client and Server ...........................................42 Installing NMS Client............................................................44 Configuring NMS Config Center..............................................47
Installing NMS for UNIX ................................................. 78 Installing NMS Client and Server ...........................................78 Installing NMS Client............................................................82 Configuring UNIX NMS Config Center .....................................85
Chapter 4......................................................................117
VCS4.3 for Windows ....................................................117 Overview ................................................................... 117 System Requirements.................................................. 118 Installation Preparations .............................................. 118
Hardware ......................................................................... 119 Hardware Connection......................................................... 119 Disk Array Connections ...................................................... 119
Installing Operating System.......................................... 121 Dividing Disk Array............................................................ 122 Configuring Network .......................................................... 122 Configuring Domain ........................................................... 124
Installing VCS HA Software........................................... 131 Creating Disk Array Logical Partition..................................... 139 VCS Software Configuration - Create Cluster ......................... 146
Installing Sqlserver Database........................................ 154 Configure SQL Server Startup Type...................................... 155 Installing NMS .................................................................. 156 VCS Software Configuration – Create SqlServer Resource Group...................................................................................... 157 VCS Software Configuration ................................................ 162
Test Dual System Hot Backup Software.......................... 182 Test Single System............................................................ 182 Test Dual Systems............................................................. 183 Test Rules for Local Dual Hot Backup System ........................ 183
Chapter 5......................................................................185
VCS4.0 for Unix............................................................185 Overview ................................................................... 185
Dual Hot Backup Configuration Requirements........................ 185 System Installation ..................................................... 187
Solaris9 Operating System Installation................................. 187 Disk Array Partition ........................................................... 191 Setting Network................................................................ 200 Installing Oracle Database.................................................. 203 Installing VCS4.0 .............................................................. 208
Configuring VCS System .............................................. 227 Starting VCS Cluster Manager............................................. 227 Adding Oracle Resource Group............................................ 229 Adding NM Resource Group ................................................ 237
NM Dual System Test Rules .......................................... 251 System Security ......................................................... 252
Appendix A...................................................................255
Handling Common VCS Problems in UNIX..................255 Modifying VCS Cluster Administrator Password ................ 255 Checking Heartbeat ..................................................... 256 Checking Running Status.............................................. 256 Starting VCS in Abnormal Status ................................... 256 Failed to Start Oracle Database after Switchover ............. 257 Faulty VCS Resource Group or Resource......................... 258 Uninstalling VCS ......................................................... 259
Appendix B...................................................................261
Common UNIX Operation Commands.........................261 File System Operation Commands ................................. 261 System Commands ..................................................... 263 Pack/Unpack Command ............................................... 264 Important System Files................................................ 264
Appendix C ...................................................................267
Common Oracle Database Operations ........................267 Starting Oracle8i Database Service ................................ 267
Starting Oracle9i Database Service ................................ 268 Viewing Oracle Service Name........................................ 268 Viewing Database Table Space Name ............................. 268 Viewing Database User ................................................ 269 Oracle Database Backup .............................................. 269 Restoring Oracle Database ........................................... 269
Appendix D...................................................................271
Abbreviations...............................................................271
Figures..........................................................................273
Tables ...........................................................................281
Index............................................................................283
Confidential and Proprietary Information of ZTE CORPORATION i
About This Manual
Purpose
This manual provides user systematic guidelines and procedures for the operations of NetNumen N31 (V4.2.0) Network Management System (General).
Intended Audience
This manual is intended for engineers and technicians who perform operation activities on NetNumen N31 (V4.2.0) Network Management System (General).
Prerequisite Skill and Knowledge
To use this manual effectively, users should have a general understanding of Network Management System. User’s knowledge in the following is helpful:
User interfaces on Network Management System (NMS)
Operating procedures on NMS
What Is in This Manual
This manual contains the following chapters:
T AB L E 1 − C H A P T E R S U M M AR Y
Chapter Summary
Chapter 1, Overview Introduces overall information of NMS, requirements, and installation.
Chapter 2, Database Installation
Describes installation and configuration of oracle 9i for UNIX.
Chapter 3, NMS Installation
Describes installation and configuration of NMS client and server.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
ii Confidential and Proprietary Information of ZTE CORPORATION
Chapter Summary
Chapter 4, NM Dual Hot Backup System Installation (VCS4.3 for Windows)
Describes the installation of NetNumen N31 (V4.2.0) dual hot backup system VCS4.3 in Windows operating system.
Chapter 5, NM Dual Hot Backup System Installation (VCS4.0 for Unix)
Describes the installation of NetNumen N31 (V4.2.0) dual hot backup system VCS4.0 in Solaris operating system
Related Documentation
The following documentation is related to this manual:
NetNumen N31 (V4.2.0) Network Management System (Man-Machine Interface)
NetNumen N31 (V4.2.0) User Manual
Conventions
ZTE documents employ the following typographical conventions.
T AB L E 2 − TY P O G R AP H I C AL C O N V E N T I O N S
Typeface Meaning
Italics References to other Manuals and documents.
“Quotes” Links on screens.
Bold Menus, menu options, function names, input fields, radio button names, check boxes, drop-down lists, dialog box names, window names.
CAPS Keys on the keyboard and buttons on screens and company name.
Constant width Text that you type, program code, files and directory names, and function names.
[ ] Optional parameters.
{ } Mandatory parameters.
| Select one of the parameters that are delimited by it.
Note: Provides additional information about a certain topic.
Checkpoint: Indicates that a particular step needs to be checked before proceeding further.
Tip: Indicates a suggestion or hint to make things easier or more productive for the reader.
Typographical Conventions
About this Manual
Confidential and Proprietary Information of ZTE CORPORATION iii
T AB L E 3 − M O U S E OP E R AT I O N C O N V E N T I O N S
Typeface Meaning
Click Refers to clicking the primary mouse button (usually the left mouse button) once.
Double-click Refers to quickly clicking the primary mouse button (usually the left mouse button) twice.
Right-click Refers to clicking the secondary mouse button (usually the right mouse button) once.
Drag Refers to pressing and holding a mouse button and moving the mouse.
How to Get in Touch
The following sections provide information on how to obtain support for the documentation and the software.
If you have problems, questions, comments, or suggestions regarding your product, contact us by e-mail at [email protected]. You can also call our customer support center at (86) 755 26771900 and (86) 800-9830-9830.
ZTE welcomes your comments and suggestions on the quality and usefulness of this document. For further questions, comments, or suggestions on the documentation, you can contact us by e-mail at [email protected]; or you can fax your comments and suggestions to (86) 755 26772236. You can also browse our website at http://support.zte.com.cn, which contains various interesting subjects like documentation, knowledge base, forum and service request.
Mouse Operation
Conventions
Customer Support
Documentation Support
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
iv Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION v
Declaration of RoHS Compliance
To minimize the environmental impact and take more responsibility to the earth we live, this document shall serve as formal declaration that NetNumen N31 (V4.2.0) Network Management System (General) manufactured by ZTE CORPORATION are in compliance with the Directive 2002/95/EC of the European Parliament - RoHS (Restriction of Hazardous Substances) with respect to the following substances:
Lead (Pb)
Mercury (Hg)
Cadmium (Cd)
Hexavalent Chromium (Cr (VI))
PolyBrominated Biphenyls (PBB’s)
PolyBrominated Diphenyl Ethers (PBDE’s)
…
NetNumen N31 (V4.2.0) Network Management System (General) manufactured by ZTE CORPORATION meet the requirements of EU 2002/95/EC; however, some assemblies are customized to client specifications. Addition of specialized, customer-specified materials or processes which do not meet the requirements of EU 2002/95/EC may negate RoHS compliance of the assembly. To guarantee compliance of the assembly, the need for compliant product must be communicated to ZTE CORPORATION in written form.
This declaration is issued based on our current level of knowledge. Since conditions of use are outside our control, ZTE CORPORATION makes no warranties, express or implied, and assumes no liability in connection with the use of this information.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
vi Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 1
C h a p t e r 1
Installation Overview
This chapter covers the following topics:
Network Analysis
Software Requirements
Hardware Requirements
Network Analysis NetNumen N31 (V4.2.0) supports different capacity networks. Select the appropriate Network Management System (NMS) type according to number of Network Elements (NE) present on the network.
The four different types of networks are listed in Table 4.
T AB L E 4 – N E T W O R K TY P E S
Type NE Capacity
NetNumenN31V4-EXX-S-1.0 (Small Scale Networks)
< 300
NetNumenN31V4-EXX-M-1.0 (Medium Scale Networks)
300 ~ 800
NetNumenN31V4-EXX-L-1.0 (Large Scale Networks)
800 ~ 1500
NetNumenN31V4-EXX-U-1.0 (Very Large Scale Networks)
1500 ~ 3000
An equivalent NE stands for one managed object in NMS. The NMS assigns the different functions to each managed object, which acts as one unit. Different types of device have different functions.
An equivalent NE example is listed in Table 5.
Network Selection
Network Element
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
2 Confidential and Proprietary Information of ZTE CORPORATION
T AB L E 5 − E Q U I V AL E N T NE E X AM P L E
NE Equivalent NE
MSAG 5200 One Equivalent NE
Software Requirements NetNumen (V 4.2.0) NMS supports MS Windows and UNIX System platforms.
MS Windows requirements are:
MS Windows (2000, 2003 or XP) with latest service pack
SQL Server 2000 Database, SQL Server 2005 Database
Latest SQL server Database Patch (SQL Server SP4)
Solaris requirements are:
Sun Solaris (9 or above) with latest service pack
Oracle 9i database
Latest Oracle Database Patch
Note: Install SQL Server 2000, 2005 or Oracle 9i database prior to NMS installation.
Hardware Requirements MS Windows and Sun Solaris operating systems are normally used as platforms for NetNumen N31 (V4.2.0) NMS. These operating systems need different hardware requirements on server and client machines.
The following are the hardware requirements for NMS installation:
Single System Requirements for Windows
Single System Requirements for UNIX
Dual System Requirements for Windows
Dual System Requirements for UNIX
Hardware Firewall
Platform Support
Windows Requirements
Sun Solaris Requirements
Platforms
Requirements
Chapter 1 Installation Overview
Confidential and Proprietary Information of ZTE CORPORATION 3
Single System Requirements for Windows
Minimum requirements for windows single system platform for NetNumen N31 (V4.2.0) are as follows:
Hardware Platform
Outsourcing Software
Accessories
Minimum requirements for the hardware platform are listed in Table 6.
T AB L E 6 − NT S E R V E R C O N F I G U R AT I O N
Name Configuration Requirements
Small One server recommended configuration: 1 Xeon 2.8G/2G/2﹡73G/, 2*10/100/1000M Ethernet ports
Medium One server recommended configuration: 2﹡ Xeon/4G/2 ﹡ 73G/, 2*10/100/1000M Ethernet ports)
Large One server recommended configuration: 2﹡ Xeon/6G/2 ﹡ 73G/, 2*10/100/1000M Ethernet ports)
Server
Huge One server recommended configuration: 4﹡ Xeon or more /8G/2﹡73G/, 2*10/100/1000M Ethernet ports)
Client Number depends on the central office requirements
Interface Computer
Number: 1; it needs to provide 1 suit when SS1b, 9000 are connected to upper-level NM via CLI. Configuration is the same as that for client.
Note: Server configuration is recommended therefore select larger configuration depends upon actual (2﹡73G hard disk as RAID)
Minimum requirements for the outsourcing software are listed in Table 7.
T AB L E 7 − OU T S O U R C I N G SO F T W AR E
Name Configuration Requirements
SQL Server 2000 Standard Version
Number: 1
Requirements
Hardware Platform
Outsourcing Software
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
4 Confidential and Proprietary Information of ZTE CORPORATION
Name Configuration Requirements
Windows Server 2003 Standard Version
Number: 1
Windows XP Number of packages must be equal to number of client machines and interface computer
Anti-virus Software Enterprise Version
Minimum requirements for the accessories are listed in Table 8.
T AB L E 8 − AC C E S S O R I E S
Name Configuration Requirements
Server Shelf Configure the server on shelf if needed
Layer-2 Switch Number: 1; template does not supply Layer- 2 switch; directly transfer it from Data Division if necessary. Recommended type: 2818S-LE AC power supply
Hardware Firewall Number: 1; selective; for option instructions, refer “1.3.3 Hardware Firewall Instruction”. The current type is: Juniper SSG-520-001
Alarm Warning Box Number: 1
Single System Requirements for UNIX
Minimum requirements for UNIX single system platform for NetNumen N31 (V4.2.0) are as follows:
Hardware Platform
Outsourcing Software
Accessories
Do not configure UNIX server unless central office requirements are not completed.
Minimum requirements for the hardware platform are listed in Table 9.
T AB L E 9 − H A R D W A R E P L AT F O R M
Name Configuration Requirements
Server Small Number: 1; SUN V240 (UltraSPARC IIIi CPU 1.34 G/2 G memory/ 2*73 G hard disk/ 4* Kilomega Ethernet port/ Solaris 9)
Accessories
Requirements
Hardware Platform
Chapter 1 Installation Overview
Confidential and Proprietary Information of ZTE CORPORATION 5
Name Configuration Requirements
Medium Number: 1; SUN V240 (UltraSPARC IIIi CPU 2*1.5G/ 4G memory/ 2*73 G hard disk/ 4*Kilomega Ethernet port/ Solaris 9)
Large Number: 1; SUN V4901(UltraSPARC IV CPU 2*1.35 G CPU/8 G memory/ 2*146G harddisk/4* Kilomega Ethernet port/ Solaris 9)
Huge Number: 1; SUN V4901(UltraSPARC IV CPU 4*1.35 G CPU/16 G memory/ 2*146G optical interface harddisk/4* Kilomega Ethernet port/ Solaris 9)
Client The number depends on central office requirements
Interface Computer
Number: 1; selective, it is required to provide one suit when SS1b, 9000 are connected to upper-level NM via CLI, its configuration is the same as for client.
Minimum requirements for outsourcing software are listed in Table 10.
T AB L E 10 − OU T S O U R C I N G S O F T W AR E
Name Configuration Requirements
Oracle 9i EE 9.2 Select one single-system CPU, two single-system CPU, and four single-system CPU according to CPU quantities.
Operating System
SUN built-in
Windows XP Number of packages equal to number of clients and interface computer
Anti-virus Software
Number: 1
Minimum requirements for the accessories are listed in Table 11.
T AB L E 11 − AC C E S S O R I E S
Name Configuration Requirements
Server Shelf Configure the server on shelf if needed
Layer-2 Switch Number: 1
Hardware Firewall Number: 1; selective
To improve system reliability and stability, NM server and NM client must be installed in different computer platforms.
Outsourcing Software
Accessories
Instructions
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
6 Confidential and Proprietary Information of ZTE CORPORATION
It demands higher and better hardware configuration if both server and client are configured on the same computer.
Dual System Requirements for Windows
Minimum requirements for windows dual system platform for NetNumen N31 (V4.2.0) are as follows:
Hardware Platform
Outsourcing Software
Accessories
Minimum requirements for the hardware platform are listed in Table 12.
T AB L E 12 − HAR D W AR E P L A T F O R M
Name Configuration Instruction
Medium 2 Servers (Single system recommended configuration + disk array (5﹡73G)
Large 2 Servers (Single system recommended configuration + disk array (5﹡73G)
2 Servers + 1 Disk Array
Huge 2 Servers (Single system recommended configuration + disk array (5﹡73G)
Network Card It needs four network interfaces while configuring dual system. Normally, the server network card is not enough.
Client Number of clients depends on central office requirements
Interface Computer Number: 1; selective, it needs to provide one suit when SS1b, 9000 are connected to upper-level NM via CLI, its configuration is the same as for client.
Minimum requirements for the outsourcing are listed in Table 13.
T AB L E 13 − OU T S O U R C I N G S O F T W AR E
Name Configuration Instruction
SQL Server 2000, 2 suits
SQL Server 2000, Standard version
Windows Server 2003
Windows Server 2003, Standard version
Requirements
Hardware Platform
Outsourcing Software
Chapter 1 Installation Overview
Confidential and Proprietary Information of ZTE CORPORATION 7
Name Configuration Instruction
Windows XP Number of packages must be equal to number of clients and interface computer
Minimum requirements for the accessories are listed in Table 14.
T AB L E 14 − AC C E S S O R I E S
Name Configuration Instruction
Server Shelf Configure the server on shelf if needed
Layer-2 Switch Number: 1; template does not supply Layer-2 switch; please directly transfer it from Data Division if necessary. Recommended type: 2818S-LE AC power supply
Hardware Firewall Number: 1; selective
Alarm Warning Box Depends on the central office demands
Dual System Requirements for UNIX
Minimum requirements for windows dual system platform for NetNumen N31 (V4.2.0) are as follows:
Hardware Platform
Outsourcing Software
Accessories
Minimum requirements for the hardware platform are listed in Table 15.
T AB L E 15 − HAR D W AR E P L A T F O R M
Name Configuration Instruction
Small 2* SUN V240 (Single system recommended configuration: UltraSPARC IIIi CPU 1.34 G/2 G Memory/ 2*73 G hard disk/ 4*Kilomega Ethernet port/ Solaris 9) + 1 Disk array
2 Small Capacity Machine + 1 Disk Array
Medium 2* SUN V240 (Single system recommended configuration: UltraSPARC IIIi CPU 2*1.5G CPU/ 2G Memory/ 2*73 G hard disk/ 4* Kilomega Ethernet port/ Solaris 9) + 1 Disk array
Accessories
Requirements
Hardware Platform
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
8 Confidential and Proprietary Information of ZTE CORPORATION
Name Configuration Instruction
Large 2* SUN V490 (Single system recommended configuration: UltraSPARC 1V CPU 2*1.35G CPU/ 8G Memory/ 2*146G hard disk/ 4* Kilomega Ethernet port/ Solaris 9) + 1 Disk array
Huge 2* SUN V490 (Single system recommended configuration: UltraSPARC 1V CPU 4*1.35G CPU/ 16G Memory/ 2*146G optical interface hard disk/ 4* Kilomega Ethernet port/ Solaris 9) + 1 Disk array
Client The number depends on central office requirements
Interface computer
Number: 1; selective, it needs to provide 1 suit when SS1b, 9000 are connected to upper-level NM via CLI, its configuration is the same as for client.
Minimum requirements for the outsourcing are listed in Table 16.
T AB L E 16 − OU T S O U R C I N G S O F T W AR E
Name Configurations
Oracle 9i EE 9.2
Select 2 dual-systems CPU, 4 single-systems CPU and 8 dual-systems CPU according to CPU quantities.
Operating System
SUN built-in
Windows XP Quantities equal to Client quantity + Interface computer
Small/ Medium( inner/out country) : local VCS software for SUN 1A server, Number: 1
Local VCS Software
Large/ Huge (inner/out country): local VCS software for SUN 1A server, Number: 1
Anti-virus Software
Number: 2
Minimum requirements for the accessories are listed in Table 17.
T AB L E 17 − AC C E S S O R I E S
Name Configurations
Server Shelf Configure server on shelf if needed
Layer-2 Switch Number: 1
Hardware Firewall
Number: 1; selective
Outsourcing Software
Accessories
Chapter 1 Installation Overview
Confidential and Proprietary Information of ZTE CORPORATION 9
Hardware Firewall
Common firewalls are Cisco PIX515E, 525 or Juniper Netscreen25, 50, 204, 208.
The requirements for the firewall are listed in Table 18.
T AB L E 18 − F I R E W AL L
Cisco Juniper Products
Items 515E 525 25 50 204 208
Throughput 188 M (Duplex)
360 M (Duplex)
100 M 170 M 400 M 550 M
Talk Quantity 130,000
380,000
32,000 64,000
128,000
128,000
Interface Quantity
2+4 FE/GE
2+6 FE/GE
4 4 4 8
Security Networking
Failover
Failover
HALlite Master/ Slave
Master/
Slave,
Master/Master
Master/
Slave,
Master/Master,
Master/Master overall network
The hardware firewall instructions are described as follows:
PIX firewall with UR numbering is allowed to support the maximum interfaces and memory. UR license supports redundant hot backup and minimize the network down time.
PIX firewall with R numbering is limited to support interface quantities and memory. It does not support redundant networking.
PIX firewall with FO numbering linked with another firewall with UR license provides hot redundant backup structure. FO license provides fault tolerance function based on status, which improves network structure performance.
PIX firewall with UR and FO numbering composed of failover networking need the same type (515E or 525) and same hardware configuration. Security protection between soft switch and bearer network is suggested.
Description
Instructions
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
10 Confidential and Proprietary Information of ZTE CORPORATION
Note: R and FO numbering cannot work together
PIX firewall with R and UR numbering can be used separately. PIX firewall with R and UR numbering are normally used for security protection between soft switch and management network such as DCN.
Juniper firewall port is consolidated. It usually adopts same equipment to compose master/slave, master/master, master/master safe full networking mode.
NOTE: N-25 networking mode only provides synchronized configuration instead of synchronized talking and tunnel.
The dual system firewall adopts CISCO PIX to networking as failover mode. It also can adopt two Juniper firewalls to build up master/slave networking mode.
The single system firewall can use Cisco firewall with UR and R numbering, or Juniper firewall. Cisco firewall usually configures two Ethernet interfaces and increases the number of interfaces as required.
Juniper firewall usually configures fastness port; therefore, it only demands to select type number.
Confidential and Proprietary Information of ZTE CORPORATION 11
C h a p t e r 2
Database Installation
This chapter covers the following topics:
Oracle Database Installation
SQL Server Database Installation
Oracle Database Installation This section describes the hardware and software requirements for Oracle 9i installation and configuration on Sun Solaris operating system.
This section includes the following:
Hardware Requirements
Software Requirements
Installation Preparation
Installing Oracle 9i
Configuring Database
Installing Oracle 9i Service Pack
Hardware Requirements
Minimum system hardware requirements are as follows:
CPU: SUN Blade1000 with a single CPU
RAM: 1GB
Hard disk: 70 GB
Minimum space for SWAP partition must be at least twice of the physical memory.
Minimum free space for the system must be 10 GB.
Minimum free space for the user must be 60 GB.
System Requirements
Swap Partition
Hard Disk Size
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
12 Confidential and Proprietary Information of ZTE CORPORATION
The command used to check the available disk space for user partition is shown in Figure 1.
F I G U R E 1 – SP A C E FO R U S E R P AR T I T I O N
Software Requirements
Minimum software version must be Solaris 9 or higher.
Use the following command to view operating system information:
# uname -a
SunOS nm1000 5.9 Generic_118558-38 sun4u sparc SUNW, Sun-Blade-1000
Download and install latest patch “9_Recommend.zip” from http://sunsolve.sun.com
Solaris must include the following core patches:
SUNWarc
SUNWbtool
SUNWhea
SUNWlibms
SUNWsprot
SUNWtoo
Use the following commands to view installed system PATCH: # pkginfo –i [package_name]
system SUNWzlib The Zip compression library
system SUNWzlibx The Info-Zip compression library (64-bit)
system SUNWzsh Z shell (zsh)
Command Description
Operating System
PATCH
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 13
system TSBWvplr Toshiba platform links
system TSBWvplu Toshiba usr/platform links
system TSIpgx PGX32 (Raptor GFX) System Software Device Driver
Application TSIpgxw PGX32 (Raptor GFX) X-Window System Support
system TSIpgxx PGX32 (Raptor GFX) System Software/Device Driver (64-bit)
system TWSvplr TWS platform links
system TWSvplu TWS usr/platform links
Make sure that the following execution files exist in the directory /usr/ccs/bin:
Make
Ar
Ld
nm
The following command is used to verify X-Window system running status is normal.
# xclock
A graphic clock interface pop up implies a normal X-Windows system. If no graphic clock interface pops up, it means an abnormal X-Windows.
Installation Preparation
To provides pre-installation guidelines for the user.
None
To install oracle database, perform following pre-installation steps:
1. Run Login as a ‘root’ user.
2. Click Files and Open Terminal in File Manager window as shown in Figure 1 the Terminal window appears with command prompt # sign. Input commands after # sign and press enter key to execute. #su - root command is used to switch the root user and enter password if prompted.
3. Configure UNIX core parameters for Oracle 9i.
i. Right click on desktop short cut menu appears, click Folder and check File Manager – Home. File Manger window appears as shown in Figure 6. Open etc folder then run System file.
ii. Following are the additions or modifications in UNIX system core parameters for Oracle 9i:
set semsys:seminfo_semmni=100
set semsys:seminfo_semmns=1024
Executive Files
X-Window System Run
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
14 Confidential and Proprietary Information of ZTE CORPORATION
set semsys:seminfo_semmsl=256
set shmsys:shminfo_shmmax=4294967295
set shmsys:shminfo_shmmin=1
set shmsys:shminfo_shmmni=100
set shmsys:shminfo_shmseg=10
iii. Save and close the file.
4. Create Oracle group.
i. Add three user groups ‘install’, ‘apchadm’ and ‘dba’ in the system administration tools.
ii. Use the following command to open system administration tools in the Terminal window:
# admintool
iii. From the main menu, click Browse and select the Group from admin tool windows. Admintool: Group window appears as shown in Figure 2.
F I G U R E 2 – AD M I N TO O L : GR O U P S
iv. From the main menu of Admin Tool: Group, click Edit and Add, Admintool: Add Group window appears as shown in Figure 3. Assign Group Name, Group ID, Member List and click OK.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 15
F I G U R E 3 – AD M I N T O O L : AD D GR O U P
5. Create Oracle user
i. Add users oracle, apache and adm in the system administration tools.
ii. Add a user oracle used for oracle database. From the main menu of Admin Tool: Users, click Edit and Add. Admintool: User window appears as shown in Figure 4.
F I G U R E 4 – AD M I N T O O L : AD D U S E R WI N D O W
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
16 Confidential and Proprietary Information of ZTE CORPORATION
iii. Configure the following parameters (use the system default values, if the following contents are not listed):
User Name: oracle
Primary Group: install
Secondary Groups: dba
Login Shell: Bourne
Password: Select Normal Password from Password drop down list (Input the oracle user password in both fields, oracle is recommended).
HOME DIRECTORY: Home directory route is the oracle database required for installation. It can change according to the different user.
Path: /export/home/Oracle (/export/home is supposed to be the system user partition here)
iv. Add a user apache. It is used for oracle HTTP server. From the main menu of Admin Tool: Users, click Edit and Add, Admintool: User window appears as shown in Figure 5.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 17
F I G U R E 5 – AD M I N T O O L : AD D U S E R WI N D O W
v. Configure the following parameters (use the system default values, if the following contents are not listed):
User Name: apache
Primary Group: install
Secondary Groups: apchadm
Login Shell: Bourne
Password: Select Normal Password from Password drop down list (Input the oracle user password in both fields, Apache is recommended).
HOME DIRECTORY: Home directory route is the oracle database required for installation. It can change according to the different user.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
18 Confidential and Proprietary Information of ZTE CORPORATION
Path: /export/home/apache (/export/home is supposed to be the system user partition here.)
vi. Click OK to finish the operation.
Note: Make sure that installation path is under system user’s partition directory. It is forbidden to install it under UNIX system directory such as root directory/usr/var/tmp.
6. Operation for oracle user
i. Switch the previous root user to oracle user. Input $su–oracle command in the Terminal. If it is successful, set the environment variables of oracle user.
ii. Right click on desktop shortcut, click Files and File Manager. File Manager window appears as shown in Figure 6. Open the directory /export/home/oracle. Click View and check Show Hidden Objects from the main menu.
F I G U R E 6 − SH O W H I D D E N OB J E C T S
iii. Open the .profile file. Text Editor - .profile window appears as shown in Figure 7.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 19
F I G U R E 7 – TE X T E D I T O R – . P R O F I L E W I N D O W
iv. Configure the following environment variables if required:
umask 022;export umask
DISPLAY=Workstation_name:0.0;export DISPLAY (Workstation_name is the machine name. If the machine name is NM9000, DISPLAY=NM9000:0.0)
ORACLE_TERM=vt100; export ORACLE_TERM
ORACLE_BASE=/export/home/oracle;export ORACLE_BASE
ORACLE_HOME=/export/home/oracle/product/9.2.0; export RACLE_HOME (Set the installation path of Oracle database system program.)
ORACLE_SID=uep; export ORACLE_SID (Set the service name of Oracle database as uep.)
ORA_NLS33=$ORACLE_HOME/ocommon/nls/admin/data;
export ORA_NLS33 (Set the output character group of Oracle database.)
LD_LIBRARY_PATH=$ORACLE_HOME/lib:/lib:usr/lib:$LD_LIBRARY_PATH
export LD_LIBRARY_PATH
NLS_LANG=american_america.ZHS16GBK; export NLS_LANG (Set the output character group of Oracle database.)
TMPDIR=/tmp; export TMPDIR
PATH=$ORACLE_HOME/bin:/usr/ccs/bin:/usr/bin:/usr/ucb:etc:/usr/openwin/bin:/usr/local/bin:
export PATH
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
20 Confidential and Proprietary Information of ZTE CORPORATION
Note: Information in small brackets () is only for user comments; should not be modified in the file.
7. Switch back to the root user to finish the operations.
8. Use the following command in Terminal window to restart the system:
# init 6
9. Login again as root user after system restarts.
END OF STEPS
Pre-installation steps are completed successfully.
Installing Oracle 9i
To install Oracle database.
None
To install Oracle 9.2.0.7 for Solaris, perform the following steps:
1. Execute runInstaller.sh file from the path /export/home/oracle to start installation wizard. The installation process begins automatically as shown in Figure 8.
F I G U R E 8 − RU N W I N D O W
2. The installation wizard prompts to extract all the zip files as shown in Figure 9. Enter y to continue the installation process.
Result
Purpose
Preliminary Steps
Steps
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 21
F I G U R E 9 − PR O M P T W I N D O W
3. The installation wizard starts extracting all the installation files as shown in Figure 10.
F I G U R E 10 − E X T R AC T I N G F I L E S
Note: Wait for some time. Usually it takes few minutes to extract all the installation files.
4. Oracle installation is finished successfully as shown in Figure 11.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
22 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 11 − IN S T AL L AT I O N F I N I S H E D
END OF STEPS
Oracle 9.2.0.7 database is installed successfully.
Oracle 9i Post Installation Check
To check Oracle database is running properly.
None
To check whether Oracle database is running properly, perform the following steps:
1. Execute the following command to switch to Oracle user as shown in Figure 12. The prompt changes to $.
#su - oracle
2. Execute the following command to start SQL Plus. The prompt changes to SQL>.
$sqlplus /nolog
3. Execute the following command to connect to idle instance. Enter user name and password.
SQL>connect as sysdba.
4. Execute the following command to start Oracle instance process.
SQL>startup
5. Execute the following command to disconnect from oracle 9i.
SQL>exit
Results
Purpose
Preliminary Steps
Steps
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 23
F I G U R E 12 – TE R M I N AL W I N D O W
6. Execute the following commands to start listening process as shown in Figure 13.
$lsnrctl
LSNRCTL>start
F I G U R E 13 – L I S T E N I N G P R O C E S S W I N D O W
END OF STEPS
Oracle 9i database is running properly.
Configuring Database
To configure database.
None
To configure database, perform the following steps:
1. Confirm and modify parameters before executing oracle scripts.
Results
Purpose
Preliminary Steps
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
24 Confidential and Proprietary Information of ZTE CORPORATION
2. Check time format i-e YYYY-MM-DD HH24: MI: SS. Check nls_date_format properties in the init.ora file to confirm. If this parameter is not configured or format is wrong, perform following steps:
For oracle8i:
i. Shut down the database first. Modify these two files: <oracle_home>\admin\<sid>\pfile\init.orat and <oracle_home>\ora817\sysman\ ifiles\def_<sid>_<ipaddr>.ora
ii. Add nls_date_format = 'YYYY-MM-DD HH24:MI:SS' in the files.
iii. Save the files and reboot the database.
For oracle9i:
i. Switch to ‘oracle’ user: #su – oracle
ii. Start SQL*PLUS: $sqlplus /nolog
iii. Log on as ‘sysdba’: SQL>connect system/manager as sysdba
iv. Shutdown the database: SQL>shutdown
v. Export parameter file $ORACLE_HOME/dbs/inituep.ora (if the export fails, delete the existing $ORACLE_HOME/dbs/inituep.ora): SQL>create pfile from spfile
vi. Add a line in $ORACLE_HOME/dbs/inituep.ora:
*.nls_date_format = 'YYYY-MM-DD HH24:MI:SS'
vii. Import into $ORACLE_HOME/dbs/spfileuep.ora (if the import fails, shutdown the database and delete the existing $ORACLE_HOME/dbs/spfileuep.ora)
viii. Create profile as SQL>create spfile from pfile
ix. Restart the database: SQL>startup and verify if modification is correct:
SQL>show parameters nls_date_format
NAME TYPE VALUE
------------------------------------------------
nls_date_format string YYYY-MM-DD HH24:MI:SS
3. Confirm that oracle’s character set is ZHS116GBK
i. Modify two parameters in ‘props$’ table of the ‘sys’ scheme:
NLS_CHARACTERSET= ZHS16GBK
NLS_NCHAR_CHARACTERSET=ZHS16GBK
ii. Shutdown the database and restart
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 25
4. For oracle8i, set ‘compatible’ in the startup scripts (init.ora and initXXX.ora) to ‘8.1.0’. Otherwise, problem may occur.
END OF STEPS
Database is configured successfully.
Installing Oracle9i Service Pack
To install oracle database patch. This installation takes Oracle 9.2.0.7 version as an example.
1. Confirm patches
i. Oracle 9.2.0.7 database update patch packet includes 32-bit and 64-bit software. Confirm the information before installing.
ii. For 32-bit operating system, install 32-bit oracle software. For 64-bit operating system, install both 32-bit and 64-bit oracle software.
iii. 32-bit oracle software only can install 32-bit patch packet, and 64-bit oracle software only can install 64-bit patch packet.
32-bit patch packet is p4163445_92070_SOLARIS.zip
64-bit patch packet is p4163445_92070_SOLARIS64.zip
iv. Download the patch packet from https://metalink.oracle.com.
v. Click login in metalink. Input user name and password (Please ask NM Development Department for them). After login, select patches & Updates page, then select Simple Search link as shown in Figure 14.
Results
Purpose
Important Cautious Items
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
26 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 14 − D O W N L O AD P AT C H
vi. Open Simple Search page and input patch number to choose 32-bit or 64-bit oracle software as shown in Figure 15.
F I G U R E 15 − P ATCH S E AR C H I N G
vii. Click Go to search patch result as shown in Figure 16. Click Download to start downloading.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 27
F I G U R E 16 − P AT C H S E AR C H I N G R E S U L T
2. To verify Oracle product is 32-bit or 64-bit:
Input commands under oracle user command (su – oracle):
sqlplus “/as sysdba”
The result is as follows:
# su - oracle
Sun Microsystems Inc. SunOS 5.8 Generic Patch February 2004
$ sqlplus "/as sysdba"
SQL*Plus: Release 9.2.0.1.0 - Production on Mon Feb 20 13:19:28 2006
Copyright (c) 1982, 2002, Oracle Corporation. All rights reserved.
Connected to:
Oracle9i Enterprise Edition Release 9.2.0.1.0 - Production
With the Partitioning, OLAP and Oracle Data Mining options
JServer Release 9.2.0.1.0 – Production
Among them, the third line is Connected to:. The fourth line can be one of the following contents:
Oracle9i Enterprise Edition Release 9.2.0.1.0 – Production
Oracle9i Enterprise Edition Release 9.2.0.1.0 – 64bit Production
If there is 64-bit before the last Production word, it means oracle product is 64-bit, or it is 32-bit.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
28 Confidential and Proprietary Information of ZTE CORPORATION
In addition, if execute “select * from v$version” command in sqlplus, the same information may appear.
3. Requirements for oracle general installer version
This installation patch includes one oracle standard installer, version 10.1.0.4. Use this installer instead of the installer in 9.2x version or that under oracle installation directory. This patch is not complete software. Install it on a currently existing Oracle9i version. In other words, it means that former Oracle version 9.2.0.x.x is required.
4. Requirements for system
Operating systems are: Solaris 8, Solaris 9 or Solaris 10.
Oracle version is Oracle9i release 2 (9.2.0.1.0) or later.
The version after installation is 9.2.0.7.0.
Perform the following steps:
1. Download and decompress installation software.
i. Select download software according to the original installation oracle bit.
32-bit patch pack is: p4163445_92070_SOLARIS.zip
64-bit patch pack is: p4163445_92070_SOLARIS64.zip
ii. Do not place the patch in the installation directory and sub-directory. Create a new directory to place patch pack, for example, Oracle_patch.
iii. The decompressed contents are saved in patch saving directory.
$ unzip p4163445_9207_solaris64.zip
2. Guarantee the establishment of environment parameter ORACLE_HOME and ORACLE_SID is correct.
Login the account as oracle. Confirm the environment parameter set is correct, check result by executing env command.
3. Stop oracle database and relevant process instances.
i. Shutdown the current normal and direct prior-level oracle server instance. Stop all monitoring program, agency and other programs in ORACLE_HOME.
ii. Shutdown oracle example in oracle user account. Run sqlplus /nolog, and link by connect /as sysdba, then execute shutdown command.
iii. Shutdown oracle monitoring method is: Start-up lsnrctl as oracle account, and execute stop command.
4. Backup the system. (Selective)
Backup original oracle9i installation and database data before patch installing.
Steps before Patch
Installation
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 29
Patch installation steps including interactive and non-interactive installation.
Interactive installation: When installing patch in one version, which is not Oracle9i version, installer prompts warning dialog box including the following error message:
There are no patches that need to be applied from the patch set oracle9i patch set 9.2.0.7.0.
Oracle general installer is not allowed to continue this installation process, click OK on dialog, and then click Cancel to exit.
Installation steps are as follows:
1. Login account as oracle.
2. To install patch from telnet installation mode via Xmanager, perform the following actions:
Input the below commands to display direct X applications in local system, and change local_host IP into Xmanager‘s IP address.
% setenv DISPLAY local_host:0.0
3. Input the following commands to start-up installer, which is under patch decompress directory.
cd Oracle_patch/Disk1
./runInstaller
4. Click Next on Welcome page, File Location window appears.
5. On File Locations page, click Browse and select original file near to Name field in source area.
6. Select products xml file of Disk1/stage under patch decompress directory. For example, this file is: Oracle_patch/Disk1/stage/products.xml.
7. In Name field of destination area of this page, select Oracle Home directory that need to install patch from drop-down list. Click Next to enter Summary page.
8. Summary page lists all relevant patches and original file. Click Install.
9. Installation process is interrupted, use root account to execute $ORACLE_HOME/root.sh. At the same time, start another client to login using root account, execute root.sh of $ORACLE_HOME.
10. On end page, click Exit, then click Yes to exit.
Perform the following steps after patch installation:
1. Check system table space: At least 10 M space is available.
Patch Installation
Steps
Steps after Patch
Installation
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
30 Confidential and Proprietary Information of ZTE CORPORATION
2. Set two initialization parameters: SHARED_POOL_SIZE and JAVA_POOL_SIZE.
Before executing the updated root version catpatch.sql, confirm the two parameter values are not less than 150 MB.
Login as oracle, and start up database:
$ sqlplus “ /as sysdba”
SQL > STARTUP
Check the two parameters.
Note: The unit is byte. 1 MB is equal to 1048576 bytes.
SQL> SHOW PARAMETER SHARED_POOL_SIZE
SQL> SHOW PARAMETER JAVA_POOL_SIZE
If the value is less than 157286400, and system uses server parameter file, execute the following commands to modify value:
SQL> ALTER SYSTEM SET SHARED_POOL_SIZE='150M' SCOPE=spfile;
SQL> ALTER SYSTEM SET JAVA_POOL_SIZE='150M' SCOPE=spfile;
Shutdown database:
SQL >shutdown
3. Update database
Login as oracle.
Start up oracle monitor.
$ lsnrctl start
Use SQL*Plus and log in as SYS user.
$ sqlplus /nolog
SQL> CONNECT / AS SYSDBA
Execute the following commands. Use the full path of ORACLE_HOME to replace the part of <?>.
Note: The process may last a long time. Do not terminate it.
The system saves this operation to patch.log.
SQL> STARTUP MIGRATE
SQL> SPOOL patch.log
SQL> @?/rdbms/admin/catpatch.sql
SQL> SPOOL OFF
Check patch.log file. It includes every server version and status in database. If there is any mistake, modify and update as above commands.
Reboot database:
SQL> SHUTDOWN
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 31
SQL> STARTUP
Run utlrp.sql root version, and re-edit all invalid PL/SQL packets immediately.
Note: Replace <?> with ORACLE_HOME path.
SQL> @?/rdbms/admin/utlrp.sql
SQL Server Database Installation To install SQL server 2000 database.
None
To install SQL server database installation, perform the following steps:
1. Insert the installation disk in CD-ROM. The installation wizard automatically starts installation process as shown in Figure 17.
F I G U R E 17 − SQL S E R V E R 2000 I N S T AL L AT I O N S C R E E N
Note: If the installation wizard does not start automatically, explore installation CD and double-click Autorun.exe in root directory.
Purpose
Preliminary Steps
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
32 Confidential and Proprietary Information of ZTE CORPORATION
2. Click SQL Server 2000 Components as shown in Figure 18.
F I G U R E 18 − SQL S E R V E R 2000 I N S T AL L AT I O N S C R E E N
Result: Install Components window appears as shown in Figure 19.
F I G U R E 19 − IN S T AL L C O M P O N E N T S WI N D O W
3. Click Install Database Server to start database installation as shown in Figure 20.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 33
F I G U R E 20 − IN S T AL L AT I O N P R E P AR AT I O N S W I N D O W
Result: The wizard starts installation preparations. Wait while the wizard completes preparation and Welcome window appears as shown in Figure 21.
F I G U R E 21 − W E L C O M E W I N D O W
4. Read the instructions carefully. Click Next and Computer Name window appears as shown in Figure 22.
F I G U R E 22 − C O M P U T E R NAM E W I N D O W
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
34 Confidential and Proprietary Information of ZTE CORPORATION
5. Select Local Computer to install database on local machine and click Next.
6. Select Create a new instance of SQL Server, or install Client Tools and click Next. Wizard also shows help for selected option as shown in Figure 23.
F I G U R E 23 − IN S T AL L AT I O N S E L E C T I O N W I N D O W
7. Specify Name and Company details and click Next as shown in Figure 24.
F I G U R E 24 − U S E R I N F O R M AT I O N W I N D O W
8. Software License Agreement window appears as shown in Figure 25. Click Yes to accept agreement and continue with installation.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 35
F I G U R E 25 − S O F T W AR E L I C E N S E AG R E E M E N T W I N D O W
9. Choose Server and Client Tools and click Next as shown in Figure 26.
F I G U R E 26 − I N S T AL L AT I O N D E F I N I T I O N W I N D O W
10. Make sure that Default is checked and click Next as shown in Figure 27.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
36 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 27 − I N S T AN C E N A M E W I N D O W S
11. Choose Typical (setup type) and click Browse to specify a destination folder for SQL Server as shown in Figure 28.
F I G U R E 28 − IN S T AL L AT I O N TY P E S W I N D O W
12. Select Use the same account for each service. Auto start SQL Server Service. Under Service Settings select Use the Local System account and click Next as shown in Figure 29.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 37
F I G U R E 29 − S E R V I C E AC C O U N T S W I N D O W
13. Choose Mixed Mode and provide a password. Click Next as shown in Figure 30.
F I G U R E 30 − AU T H E N T I C AT I O N M O D E W I N D O W
14. Read the instructions and click Next as shown in Figure 31.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
38 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 31 − S T AR T C O P Y I N G F I L E W I N D O W
15. Select Per Seat for licensing mode and input 10 for devices as shown in Figure 32.
F I G U R E 32 − C H O O S E L I C E N S I N G M O D E W I N D O W
Tip: Wait until the installation completes.
16. Figure 33 shows installation progress.
Chapter 2 Database Installation
Confidential and Proprietary Information of ZTE CORPORATION 39
F I G U R E 33 − INST ALL ATION P R O G R E S S W I N D O W
F I G U R E 34 − S T AR T I N G S E R V E R W I N D O W
F I G U R E 35 − U P D A T I N G S Y S T E M W I N D O W
17. Read the installation summary and click Finish to complete the setup as shown in Figure 36.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
40 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 36 − IN S T AL L AT I O N C O M P L E T E D I AL O G B O X
END OF STEPS
SQL server installation is completed successfully.
NOTE: Install latest patch after SQL Server 2000 installation.
Result
Confidential and Proprietary Information of ZTE CORPORATION 41
C h a p t e r 3
NMS Installation
This chapter covers the following topics:
Overview
Installing NMS for Windows
Installing NMS for Unix
Overview NMS provides eight management functions: Performance Management, Report Management, Topology Management, Security Management, Log Management, System Management, Policy Management, and Fault Management.
NetNumen N31 (V4.2.0) provides high flexibility to add new servers while the system is running to meet the growing number of customer access. Provides fault tolerance capability, if one server fails others can take over to ensure uninterrupted service.
NetNumen N31 (V4.2.0) supports web based network management capability via a secure control mechanism.
Supports optimal access authority control and provide log records to accomplish system security.
NetNumen N31 (V4.2.0) supports following two types of installation modes:
Client and Server: Installs both client and server on same machine. Choose this option for server machines.
Client only: Installs only client on machine. Choose this option for client machines.
Large Scale Distributed
System
Remote Management
System Security
Installation Modes
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
42 Confidential and Proprietary Information of ZTE CORPORATION
Installing NMS for Windows This section includes the following:
Installing NMS Client and Server
Installing NMS Client
Installing NMS Config Center
Installing NMS Client and Server
To install NMS client and server.
None
To install client and server, perform the following steps:
1. Run the installation CD-ROM. Execute the file install.bat if installing NMS for MS Windows and install.sh if installing for Sun Solaris. The installer wizard prompts to select the language for installation. Figure 37 shows NetNumen N31 installation progress in command prompt windows.
F I G U R E 37 – N E T N U M E N I N S T AL L AT I O N (W I N D O W S )
2. Select 1 for English and press return key to start extracting files as shown in Figure 38.
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 43
F I G U R E 38 – S E L E C T I N G LAN G U AG E – N E T N U M E N
3. Specify target directory and press return key to start the installation as shown in Figure 39.
F I G U R E 39 – D I R E C T O R Y SE L E C T I O N I N N E T N U M E N
Important: If target directory is not selected then system installs automatically in c:\netnumen directory
4. Select 2 for Client and Server installation and press return key to extract platform.zip files as shown in Figure 40.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
44 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 40 – E X T R AC T I N G P L AT F O R M F I L E S
Important! Wait while unpacking platform.zip file, it takes some time to complete unpacking process.
END OF STEPS
NMS Client and Sever is Installed successfully.
Installing NMS Client
To install NMS client.
None
To install NMS client, perform the following steps:
1. Run the installation CD-ROM. Execute the file install.bat if installing NMS for MS Windows and install.sh if installing for Sun Solaris. The installer wizard prompts to select the language for installation. Figure 41 shows NetNumen N31 installation progress in command prompt windows.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 45
F I G U R E 41 – N E T N U M E N I N S T AL L – NMS C L I E N T
2. Select 1 for English then press return key to start extracting files as shown in Figure 42.
F I G U R E 42 – S E L E C T I N G LAN G U AG E - NMS C L I E N T
3. Specify target directory and press return key to start the installation as shown in Figure 43.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
46 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 43 – D I R E C T O R Y SE L E C T I O N NMS C L I E N T
Important: If target directory is not selected then system installs automatically in c:\netnumen directory
4. Select 1 for Client installation and press return key to extract platform.zip files as shown in Figure 44.
F I G U R E 44 – E X T R AC T I N G P L AT F O R M F I L E S NMS C L I E N T
Important! Wait while unpacking platform.zip file, it takes some time to complete unpacking process.
END OF STEPS
NMS client is installed successfully. Result
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 47
Configuring NMS Config Center
NMS configuration center is used to configure common configurations, EPM parameters configuration and common maintenance.
This section includes the following:
Running Config Center
Basic information
NE Module
Database
FTP Service
Client Update
Policy Configuration
System Log Information
NE Type
Shortcut
Other
Analog Input Parameters
Digital Input Parameters Configuration
Digital Output Parameters Configuration
Power Parameters Configuration
Import (Export) Configuration
Running Config Center
To run the config center.
NMS client and server must be installed.
To run the config center, perform the following steps:
1. Click start then select Programs → NetNumen N31 → Tools → NetNumen N31 Config Center as shown in Figure 45.
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
48 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 45 – R U N N I N G NMS C O N F I G C E N T E R
2. NetNumen Config Center window is shown in Figure 46.
F I G U R E 46 – N E T N U M E N CO N F I G C E N T E R W I N D O W
END OF STEPS
Config center runs successfully.
Result
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 49
Basic Information
To view the NMS basic information.
NMS client and server must be installed.
To view the basic information, perform the following step:
Click on Basic Info under Common Config tree. Basic info tab appears as shown in shown in Figure 47. Under Common Configuration menu, Basic Information tab provides the following information:
NMS Version
Platform Version
Operating System
JAVA Version
Database Information
NMS Language
NMS Logger Level
Total Threads
Server and Client Memory
Auto Optimize Facility
F I G U R E 47 – B AS I C I N F O R M AT I O N T AB
END OF STEPS
Basic information is viewed successfully.
Purpose
Preliminary Setup
Steps
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
50 Confidential and Proprietary Information of ZTE CORPORATION
NE Module
To view information about installed and uninstalled devices.
NMS client and server must be installed.
To view installed or uninstalled NE module information, perform the following steps:
Click on NE Module under Common Config tree. NE Module tab provides information about installed and uninstalled devices as shown in Figure 48.
F I G U R E 48 – NE M O D U L E TAB
END OF STEPS
NE module is viewed successfully.
Database
To optimize and test connection with the database.
NMS client and server must be installed.
To optimize and test the database, perform the following steps:
1. Click on Database under Common Config tree. DataBase tab appears as shown in Figure 49.
Purpose
Preliminary Setup
Steps
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 51
F I G U R E 49 – D AT AB AS E T A B
2. Data Type, DataBase Language, and OS information are shown on right pane of DataBase tab. Click DataBase Type drop-down list to select the type as shown in the Figure 50.
F I G U R E 50 – D AT AB AS E D A T A TY P E T AB
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
52 Confidential and Proprietary Information of ZTE CORPORATION
3. Double click on Database System Administration Name and set administrator name. Double click on Database System Administration Password and set administrator password as shown in Figure 51.
F I G U R E 51 – D AT AB AS E S Y S T E M AD M I N I S T R AT I O N N AM E AN D P AS S W O R D
Important! Windows based systems normally use the following two databases:
SQL Server Database: The default login username for administrator is sa and password is netnumen. Login username and password for Config Center and SQL server database must be the same.
Oracle Database: The default login username for administrator system and password is netnumen. Login username and password for Config Center and Oracle database must be the same.
4. Double click IP Address value to set IP address for dual backup system configuration as shown in Figure 52.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 53
F I G U R E 52 – D AT AB AS E IP AD D R E S S W I N D O W
Important! For single system configuration default IP address is used, but for dual backup system configuration floating IP address is used.
5. Database file path (only for HA System)
To save data for single system configuration database, path is not changed. But in dual system, set the path for saving the database data file.
6. To test the database connectivity click on Test Connection. Test connectively information is displayed in dialog box on the top of Test Connection button as shown in Figure 53.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
54 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 53 – TE S T C O N N E C T I O N D AT AB A S E
7. To optimize database configuration on the network click Optimize. Optimize database configuration on the network is displayed in dialog box on the top of Optimize button as shown in Figure 54.
F I G U R E 54 – OP T I M I Z E D AT AB AS E
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 55
Note: Test Connection and Optimize the data operation are used for SQL server database, but for Oracle database only Test Connection operation is used.
END OF STEPS
Database is tested and optimized successfully.
FTP Service
To configure FTP service.
NMS client and server must be installed.
To configure FTP service, perform the following steps:
1. Click on FTP User under Common Config tree. FTP User tab appears as shown in Figure 55.
F I G U R E 55 – FTP S E R V I C E T AB
2. To add FTP user click Add in FTP Service tab. Modify FTP User window appears as shown in Figure 56. Click OK to add user.
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
56 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 56 – AD D FTP U S E R W I N D O W
3. To modify FTP user click Modify in FTP User tab. Modify FTP User window appears as shown in Figure 57. Click OK after modifying the user information.
F I G U R E 57 – M O D I F Y FTP U S E R W I N D O W S
4. To delete FTP user click Delete in FTP User tab.
i. Information dialog box appears as shown in Figure 58. Click Yes to delete the user.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 57
F I G U R E 58 – IN F O R M AT I O N D I AL O G B O X
ii. Information dialog box again appears to show that the user is deleted successfully as shown in Figure 59.
F I G U R E 59 – IN F O R M AT I O N D I AL O G B O X
END OF STEPS
FTP user is added, modified and deleted successfully.
Client Update
To update client data.
NMS client and server must be installed.
To update client data, perform the following step:
Click on Client Update under Common Config tree Client Update tab appears as shown in Figure 60.
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
58 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 60 – C L I E N T U P D A T E T AB
END OF STEPS
Client is updated successfully.
Policy Configuration
To configure policy.
NMS client and server must be installed.
To configure the policy, perform the following steps:
Click on Policy Configuration under Common Config tree Policy Configuration tab appears as shown in Figure 61.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 59
F I G U R E 61 – P O L I C Y C O N F I G U R AT I O N T A B
Configure the following policies before using.
NM database backup policy
NMS database backup should be saved regularly on time and saved in path specified.
Alarm log management policy
This policy takes the backup of the alarms exceeding threshold (time and quantity) in csv type on time and saves them in the specified directory. The policy deletes the exceeding threshold alarm records. The save path, time threshold and quantity threshold is set in the configuration file.
Alarm table for alarm policy includes CAF_HISTORYALARM, CAF_BAKEHISALARM and CAF_INFORM, CAF_EVENT.
Operation log management policy
This policy takes the backup of the alarms exceeding threshold (time and quantity) in csv type on time and saves them in the specified directory. The policy deletes the exceeding threshold alarm records. The save path, time threshold and quantity threshold can be set in the configuration file.
Log table for log policy includes Log_Sys_Table, Log_Cmd_Table and Log_Scrt_Table.
Resource Introduction
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
60 Confidential and Proprietary Information of ZTE CORPORATION
The related policy parameters need to be configured in config center as shown in Figure 61. The parameter instructions are as follows:
1. BackupPath: Saving path of database backup file
For example,
BackupPath=d:/dbbackup or /export/home/oracle/backup
2. MysqlBinPath: abandon.
3. AlarmLogBackupPath_Table: Saving path of alarm and log backup file.
For example, AlarmLogBackupPath_Table =d:/logbackup or /export/home/logbackup
Notes: If the configured path does not exist, NM server creates it automatically. (Recommended this method)
4. isSaveByTime: Whether NM only save log in certain time or not. (Alarm log, operation log)
Default: true Recommended: true
When parameter value is true, the exceeding threshold log decides whether to backup them to AlarmLogBackupPath_Table according to Lock_BackupAlarm configuration and then delete these logs in NMS database.
5. The following parameters are used for appointing detailed saving time.
HisAlarmSaveTime (day) Default: 90 Recommended: 30
LogSaveTime (day) Default: 90 Recommended: 60
6. The following parameters are used for whether backup exceeding logs.
Lock_BackupAlarm: True (Backup)/False(Doesn’t backup)
Lock_ BackupLog: True (Backup)/False(Doesn’t backup)
isSaveByCount: Whether NM save certain quantity logs ( Alarm log, operation log)
When parameter value is true, the exceeding threshold log decides whether to backup them to AlarmLogBackupPath_Table according to Lock_BackupAlarm configuration and then delete these logs in NMS database.
7. The following parameters are used for appointing detailed saving time.
HisAlarmSaveCount: alarm quantity restriction.
Default: 300,000 Recommended: 300,000
LogSaveCount: Operation log quantity restriction.
Default: 100,000 Recommended: 100,000
Parameter Instruction
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 61
8. The following parameters are used for backup exceeded logs.
Lock_BackupLog: True (Backup)/False (Doesn’t backup)
Lock_BackupAlarm: Whether backup alarms that meet deleted conditions.
Default: true Recommended: true
For those alarms that meet deleted conditions (Time threshold and quantity threshold), backup before deleting from database.
When the parameter value is true, backup the alarms before deleting that meet the conditions. When the parameter value is false, delete alarms directly without backup.
Lock_BackupLog: whether NM need to backup logs, which meet deleted conditions.
Default: true Recommended: true
For those logs that meet deleted conditions (Time threshold and quantity threshold), backup before deleting from database.
When the parameter is true, backup the logs before deleting which meet conditions. When the parameter is false, delete logs directly without backup.
After configuring relevant policy parameters, add these policies in NM client, it saves the backup files to appointed directory according to configured parameters.
System Log Information
To add, modify and delete system log information.
NMS client and server must be installed.
To add, modify and delete system log information, perform the following steps:
1. Click on Syslog Info under Common Config tree. Syslog Info tab appears as shown in Figure 62.
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
62 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 62 – S Y S L O G IN F O T AB
2. To add a Syslog Server, click Add in Syslog Info tab. Add Syslog Server window appears as shown in Figure 63.
F I G U R E 63 – AD D I N G S Y S L O G S E R V E R WI N D O W
i. Click Add to add an NE Type as shown in Adding Syslog Server window. Add NE Type window appears as shown in Figure 64.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 63
F I G U R E 64 – AD D NE TY P E
ii. Enter NE Type and click Confirm to add the NE.
iii. To modify NE type click Modify in Add Syslog Server window. Modify NE Type window appears as shown in Figure 65. Click Confirm after modifying the NE type.
F I G U R E 65 – M O D I F Y NE TY P E
iv. To delete NE Type click Delete as shown in Figure 66.
F I G U R E 66 – AD D S Y S L O G S E R V E R
3. To modify system log server parameters click Modify in Sylog Info tab. Modify Syslog Server window appears as shown in Figure 67. Click Confirm after modifying the required parameters.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
64 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 67 – M O D I F Y S Y S L O G S E R V E R
4. To delete system log server click Delete as shown in Figure 68.
F I G U R E 68 – D E L E T E S Y L O G S E R V E R
END OF STEPS
System log information is added, modified and deleted successfully.
Result
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 65
Shortcut
To view shortcut on desktop.
NMS client and server must be installed.
To view shortcut on desktop, perform the following step:
Click on Short Cut under Common Config tree. Short Cut tab appears as shown in Figure 69. Short Cut tab provides information about shortcuts on desktop, in startup menu and path description.
F I G U R E 69 – S H O R T C U T T AB
END OF STEPS
Shortcuts are viewed on desktop successfully.
Other
To view other tab.
NMS client and server must be installed.
To view other tab, perform the following steps:
1. Click on Other under Common Config tree. Other tab provides Basic tab appears as shown in Figure 70.
Purpose
Preliminary Setup
Steps
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
66 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 70 – OT H E R T AB
2. Click Advance tab to view advance information as shown in Figure 71.
Advance tab provides the information about different platform as follows:
UEP Plate Server
NetNumen Server
UEP Plate Client
NetNumen Client
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 67
F I G U R E 71 – AD V AN C E T AB
3. To modify information double click on any parameter of Value in Basic tab. In Advance tab put cursor on the value and click one time, the value appears in Modify field. Click Modify to modify as shown in Figure 72.
F I G U R E 72 – S AV E OT H E R I N F O R M AT I O N
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
68 Confidential and Proprietary Information of ZTE CORPORATION
4. To save advance and basic information click on Save. Info dialog box appears as shown in Figure 73. Click OK to finish successfully.
F I G U R E 73 – IN F O D I AL O G B O X
END OF STEPS
Other tab is viewed successfully.
Analog Input Parameters Configuration
To configure analog input parameters.
NMS client and server must be installed.
To configure analog input parameters, perform the following steps:
1. Click on Analog Input Parameters Config under EPM Parameters Config tree. Analog Input Parameters Config window appears as shown in Figure 74.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 69
F I G U R E 74 – AN AL O G I N P U T P AR AM E T E R S C O N F I G U R AT I O N T AB
2. To add analog input parameter, click Add. Add window appears as shown in Figure 75.
F I G U R E 75 – AD D AN AL O G P AR AM E T E R S
3. To modify the required parameters, click Modify in Analog Input Parameters Config window and click OK after modifying the parameters as shown in Figure 76.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
70 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 76 – M O D I F Y AN AL O G I N P U T P AR A M E T E R S C O N F I G U R AT I O N T AB
4. To delete analog input parameters click Delete. Info window appears as shown in Figure 77. Click Yes to confirm delete.
F I G U R E 77 – IN F O
END OF STEPS
Analog input parameters are configured successfully.
Digital Input Parameters Configuration
To configure digital input parameters.
NMS client and server must be installed.
To configure digital input parameters, perform the following steps:
1. Click on Digital Input Parameters Config under EPM Parameters Config tree. Digital Input Parameters Config window appears as shown Figure 78.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 71
F I G U R E 78 – D I G I T AL I N P U T P AR AM E T E R S C O N F I G U R AT I O N T AB
2. Click Add to add digital input parameter. Add window appears as shown in Figure 79.
F I G U R E 79 – AD D I N P U T D I G I T AL P AR AM E T E R S W I N D O W
3. To modify the required parameters, click Modify in Digital Input Parameters Config window and click OK after modifying the parameters as shown in Figure 80.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
72 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 80 – M O D I F Y D I G I T AL I N P U T P A R A M E T E R S W I N D O W
4. To delete digital input device click Delete in Digital Input Parameters Config window. Info dialog box appears, click Yes to confirm delete as shown in Figure 81.
F I G U R E 81 – D E L E T E D I G I T AL I N P U T P AR AM E T E R S
END OF STEPS
Digital input parameters are configured successfully.
Digital Output Parameters Configuration
To configure digital output parameters.
NMS client and server must be installed.
To configure digital output parameters, perform the following steps:
1. Click on Digital Output Parameters Config under EPM Parameters Config tree. Digital Output Parameters Config window appears as shown in Figure 82.
Steps
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 73
F I G U R E 82 – D I G I T AL OU T P U T P AR AM E T E R S C O N F I G U R AT I O N T AB
2. Click Add to add digital input parameter. Add window appears as shown Figure 83.
F I G U R E 83 – AD D OU T P U T D I G I T AL P A R A M E T E R S WI N D O W
3. Click Modify to change the desired parameters. Select Device Name, as shown in Figure 84. Click OK to confirm the changes.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
74 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 84 – M O D I F Y D I G I T AL OU T P U T P A R A M E T E R S C O N F I G U R AT I O N
4. Click delete in Digital Output Parameters window. Info dialog box appears click Yes to confirm delete as shown in Figure 85.
F I G U R E 85 – D E L E T E D I G I T AL OU T P U T P AR AM E T E R S
END OF STEPS
Digital output parameters are configured successfully.
Power Parameters Configurations
To configure power parameters.
NMS client and server must be installed
To configure power parameters, perform the following steps:
1. Click on Power Parameters Config under EPM Parameters Config tree. Power Parameters Config window appears as shown in Figure 86.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 75
F I G U R E 86 – P O W E R P AR A M E T E R S C O N F I G U R AT I O N T A B
2. Click Add. Add window appears as shown in Figure 87.
F I G U R E 87 – AD D P O W E R PA R A M E T E R S W I N D O W
3. Click Modify in Power Parameters Config window. Modify window appears as shown in Figure 88. Click OK after modifying the required parameters.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
76 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 88 – M O D I F Y P O W E R P AR AM E T E R S C O N F I G U R AT I O N
4. Click Delete in Power Parameters Config window. Info dialog box appears, click Yes to confirm delete as shown in Figure 89.
F I G U R E 89 – D E L E T E P O W E R P AR AM E T E R S
END OF STEPS
Power parameters are configured successfully.
Import (Export) Configuration Data
To import and export configuration data.
NMS client and server must be installed.
To import and export configuration data, perform the following steps:
1. Click Import (Export) Configuration data under Common Maintenance tree. Import (Export) configuration data window appears as shown in Figure 90.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 77
F I G U R E 90 – IM P O R T (E X P O R T ) C O N F I G U R AT I O N D AT A T AB
2. To import the data click Import Configuration Data radio button then click Import. Save windows appears as shown in Figure 91. Click Save to save the data.
F I G U R E 91 – IM P O R T D AT A W I N D O W
3. To export the data click Export Configuration Data radio button then click Export. Save windows appears as shown in Figure 92.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
78 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 92 – E X P O R T D AT A W I N D O W
END OF STEPS
Data is imported and exported successfully.
Installing NMS for UNIX This section includes the following:
Installing NMS Client and Server
Installing NMS Client
Installing NMS Config Center
Installing NMS Client and Server
To install NMS client and server on UNIX system.
None
To install NMS client and server on UNIX system, perform the following steps:
1. Run the installation CD-ROM. Execute the file install.sh if installing NMS Client and Sever for UNIX system, as shown in Figure 93.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 79
F I G U R E 93 – C O N F I G C E N T E R . S H
2. After executing install.sh file the installer wizard prompts to select the language for installation. NetNumen N31 installation progress in command prompt windows is shown in Figure 94.
F I G U R E 94 – N E T N U M E N I N S T AL L
3. Select 1 for English, then press return key to start extracting files as shown in Figure 38.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
80 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 95 – N E T N U M E N I N S T AL L
4. Specify target directory and press return key to start the installation as shown in Figure 96.
F I G U R E 96 – N E T N U M E N I N S T AL L
Important: If target directory is not selected then system installs automatically in c:\netnumen directory
5. Select 1 for Client and Server installation and press return key to extract platform.zip files as shown in Figure 97.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 81
F I G U R E 97 – N E T N U M E N I N S T AL L
Important! Wait while unpacking platform.zip file, it takes some time to complete unpacking process.
6. Wait for a while to start Config Center as shown in Figure 98.
F I G U R E 98 – C O N F I G C E N T E R S T AR T S
END OF STEPS
NMS client and sever is installed successfully. Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
82 Confidential and Proprietary Information of ZTE CORPORATION
Installing NMS Client
To install NMS client on UNIX system.
None
To install NMS client on UNIX system, perform the following steps:
1. Run the installation CD-ROM. Execute the file install.sh if installing NMS client for UNIX system, as shown in Figure 99.
F I G U R E 99 – C O N F I G C E N T E R . S H
2. After executing install.sh file the installer wizard prompts to choose the language for installation. Figure 100 shows NetNumen N31 installation progress in command prompt windows.
Purpose
Preliminary setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 83
F I G U R E 100 – N E T N U M E N IN S T AL L
3. Select 1 for English, then press return key to start extracting files as shown in Figure 101.
F I G U R E 101 – N E T N U M E N IN S T AL L
4. Specify target directory and press return key to start the installation as shown in Figure 102.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
84 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 102 – N E T N U M E N IN S T AL L
Important: If target directory is not selected then system installs automatically in c:\netnumen directory
5. Select 1 for Client installation and press return key to continue extracting platform.zip file as shown in Figure 103.
F I G U R E 103 – N E T N U M E N IN S T AL L
Important! Wait while unpacking platform.zip file, it takes some time to complete the unpacking process.
6. Wait for a while to start Config Center as shown in Figure 104.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 85
F I G U R E 104 – C O N F I G C E N T E R S T AR T S
END OF STEPS
NMS Client is installed successfully.
Configuring UNIX NMS Config Center
NMS configuration center is used to configure common configurations, EPM parameters configuration and common maintenance.
This topic includes the following:
Running Config Center
Basic information
NE Module
Database
FTP Service
Client Update
Policy Configuration
System Log Information
NE Type
Shortcut
Other
Analog Input Parameters
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
86 Confidential and Proprietary Information of ZTE CORPORATION
Digital Input Parameters Configuration
Digital Output Parameters Configuration
Power Parameters Configuration
Import (Export) Configuration
Running Config Center
To run the config center.
NMS client and server must be installed.
To run the config center, perform the following steps:
1. Run configcentre.sh if installing NMS client for UNIX system, as shown in Figure 105.
F I G U R E 105 – C O N F I G U R AT I O N C E N T E R . S H
2. NMS configuration center is used to configure common configuration, EPM configuration and common maintenance as shown in Figure 106.
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 87
F I G U R E 106 – N E T N U M E N CO N F I G U R AT I O N C E N T E R T AB
END OF STEPS
Config center runs successfully.
Basic Information
To view the NMS basic information.
NMS client and server must be installed.
To view the basic information, perform the following step:
Click on Basic Info under Common Configuration tree. Basic info tab appears as shown in shown in Figure 107. Under Common Configuration menu, Basic Information tab provides the following information:
NMS Version
Platform Version
Operating System
JAVA Version
Database Information
NMS Language
NMS Logger Level
Total Threads
Server and Client Memory
Auto Optimize Facility
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
88 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 107 – B AS I C I N F O R M AT I O N T AB
END OF STEPS
Basic information is viewed successfully.
NE Module
To view information about installed and uninstalled devices.
NMS client and server must be installed
To view installed or uninstalled NE module information, perform the following steps:
1. Click on NE Module under Common Configuration tree. NE Module tab provides information about installed and uninstalled devices as shown in Figure 108. Check the NE module that is to be installed, click Save to complete the configuration.
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 89
F I G U R E 108 – NE M O D U L E T AB
2. Click Advance to deploy the NE module. Module Deploy window appears as shown in Figure 109. Check the module to be configured then click Save to save the configuration.
F I G U R E 109 – M O D U L E D E P L O Y
END OF STEPS
NE module is viewed successfully.
Database Configuration
To configure the database management.
NMS client and server must be installed.
Result
Purpose
Preliminary Setup
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
90 Confidential and Proprietary Information of ZTE CORPORATION
To configure the database management, perform the following steps:
1. Click on Database Configuration under Common Configuration tree. DataBase Configuration tab appears as shown in Figure 110.
F I G U R E 110 – D AT AB AS E T AB
2. Data Type, DataBase and OS information are shown on right pane of DataBase tab. Click DataBase Type drop-down list to select the type as shown in the Figure 111.
F I G U R E 111 – D AT AB AS E D AT A TY P E T AB
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 91
3. Double click Database System Administration Name and set administrator name. Double click Database System Administration Password and set administrator password as shown in Figure 112.
F I G U R E 112 – D AT AB AS E S Y S T E M AD M I N I S T R AT I O N N A M E AN D P AS S W O R D
Important! Oracle database: The default login username for administrator is system and password is netnumen. Login username and password for Config Center and Oracle database must be the same.
4. Double click IP Address value to set IP address as shown in Figure 113.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
92 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 113 – D AT AB AS E IP AD D R E S S W I N D O W
Important! For single system configuration default IP address is used, but for dual backup system configuration floating IP address is used.
5. Database file path (only for HA System)
To save data for single system configuration database, path is not changed. But in dual system, set the path for saving the database data file. Normally the "/ export / home / oracle / oradata path is used.
6. To test the database connectivity click on Test Connection. Test connectively information is displayed in dialog box on the top of Test Connection button as shown in Figure 114.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 93
F I G U R E 114 – TE S T C O N N E C T I O N D AT AB AS E
Note: Test Connection and Optimize the data operation are used for SQL server database, but for Oracle database only Test Connection operation is used.
END OF STEPS
Database is tested and optimized successfully.
FTP Service
To configure FTP service.
NMS client and server must be installed.
To configure FTP service, perform the following steps:
1. Click on FTP User under Common Configuration tree. FTP User tab appears as shown in Figure 115.
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
94 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 115 – FTP S E R V I C E T AB
2. To add FTP user click Add in FTP Service tab. Modify FTP User window appears as shown in Figure 116. Click OK to add the user.
F I G U R E 116 – AD D FTP U S E R W I N D O W
3. To modify FTP user click Modify in FTP User tab. Modify FTP User window appears as shown in Figure 117. Click OK after modifying the user information.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 95
F I G U R E 117 – M O D I F Y FTP U S E R W I N D O W S
4. To delete FTP user click Delete in FTP User tab.
i. Information dialog box appears as shown in Figure 118. Click Yes to delete the user.
F I G U R E 118 – I N F O R M AT I O N D I AL O G B O X
ii. Information dialog box again appears to show that user is deleted successfully as shown in Figure 119.
F I G U R E 119 – I N F O R M AT I O N D I AL O G B O X
END OF STEPS
FTP user is added, modified and deleted successfully. Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
96 Confidential and Proprietary Information of ZTE CORPORATION
Client Update
To update client data.
NMS client and server must be installed.
To update client data, perform the following step:
Click on Client Update under Common Configuration tree Client Update tab appears as shown in Figure 120.
F I G U R E 120 – C L I E N T U P D A T E T AB
END OF STEPS
Client is updated successfully.
Policy Configuration
To configure policy configuration.
NMS client and server must be installed.
To configure the policy configuration, perform the following step:
Click on Policy Configuration under Common Configuration tree Policy Configuration tab appears as shown in Figure 121.
Purpose
Preliminary Setup
Steps
Result
Purpose
Preliminary Setup
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 97
F I G U R E 121 – P O L I C Y C O N F I G U R AT I O N T A B
Configure the following policies before using.
NM database backup policy
NMS database backup should be saved regularly on time and saved in path specified.
Alarm log management policy
This policy takes the backup of the alarms exceeding threshold (time and quantity) in csv type on time and saves them in the specified directory. The policy deletes the exceeding threshold alarm records. The save path, time threshold and quantity threshold is set in the configuration file.
Alarm table for alarm policy includes CAF_HISTORYALARM, CAF_BAKEHISALARM and CAF_INFORM, CAF_EVENT.
Operation log management policy
This policy takes the backup of the alarms exceeding threshold (time and quantity) in csv type on time and saves them in the specified directory. The policy deletes the exceeding threshold alarm records. The save path, time threshold and quantity threshold can be set in the configuration file.
Log table for log policy includes Log_Sys_Table, Log_Cmd_Table and Log_Scrt_Table.
The related policy parameters need to be configured in config center as shown in Figure 61. The parameter instructions are as follows:
1. BackupPath: Saving path of database backup file
Resource Introduction
Parameter Instructions
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
98 Confidential and Proprietary Information of ZTE CORPORATION
For example,
BackupPath=d:/dbbackup or /export/home/oracle/backup
2. MysqlBinPath: abandon.
3. AlarmLogBackupPath_Table: Saving path of alarm and log backup file.
For example, AlarmLogBackupPath_Table =d:/logbackup or /export/home/logbackup
Notes: If the configured path does not exist, NM server creates it automatically. (Recommended this method)
4. isSaveByTime: Whether NM only save log in certain time or not. (Alarm log, operation log)
Default: true Recommended: true
When parameter value is true, the exceeding threshold log decides whether to backup them to AlarmLogBackupPath_Table according to Lock_BackupAlarm configuration and then delete these logs in NMS database.
5. The following parameters are used for appointing detailed saving time.
HisAlarmSaveTime (day) Default: 90 Recommended: 30
LogSaveTime (day) Default: 90 Recommended: 60
6. The following parameters are used for whether backup exceeding logs.
Lock_BackupAlarm: True (Backup)/False(Doesn’t backup)
Lock_ BackupLog: True (Backup)/False(Doesn’t backup)
isSaveByCount: Whether NM save certain quantity logs ( Alarm log, operation log)
When parameter value is true, the exceeding threshold log decides whether to backup them to AlarmLogBackupPath_Table according to Lock_BackupAlarm configuration and then delete these logs in NMS database.
7. The following parameters are used for appointing detailed saving time.
HisAlarmSaveCount: alarm quantity restriction.
Default: 300,000 Recommended: 300,000
LogSaveCount: Operation log quantity restriction.
Default: 100,000 Recommended: 100,000
8. The following parameters are used for backup exceeded logs.
Lock_BackupLog: True (Backup)/False (Doesn’t backup)
Lock_BackupAlarm: Whether backup alarms that meet deleted conditions.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 99
Default: true Recommended: true
For those alarms that meet deleted conditions (Time threshold and quantity threshold), backup before deleting from database.
When the parameter value is true, backup the alarms before deleting that meet the conditions. When the parameter value is false, delete alarms directly without backup.
Lock_BackupLog: whether NM need to backup logs, which meet deleted conditions.
Default: true Recommended: true
For those logs that meet deleted conditions (Time threshold and quantity threshold), backup before deleting from database.
When the parameter is true, backup the logs before deleting which meet conditions. When the parameter is false, delete logs directly without backup.
After configuring relevant policy parameters, add these policies in NM client, it saves the backup files to appointed directory according to configured parameters.
System Log Information
To configure system log information.
NMS client and server must be installed.
To configure system log information, perform the following steps:
1. Click on Syslog NBI Info under Common Configuration tree. Syslog NBI Info tab appears as shown in Figure 122.
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
100 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 122 – S Y S L O G NBI I N F O T AB
2. To add a Syslog Server, click Add in Syslog NBI Info tab. Add Syslog Server window appears as shown in Figure 123.
F I G U R E 123 – AD D I N G S Y S L O G S E R V E R WI N D O W
i. Click Add to add an NE Type as shown in Adding Syslog Server window. Add NE Type window appears as shown in Figure 124.
ii. Enter NE Type and click Confirm to add the NE as shown in Figure 124.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 101
F I G U R E 124 – AD D NE TY P E
iii. To modify NE type click Modify in Add Syslog Server window. Modify NE Type window appears as shown in Figure 125. Click Confirm after modifying the NE type.
F I G U R E 125 – M O D I F Y NE TY P E
iv. To delete NE Type click Delete as shown in Figure 126.
F I G U R E 126 – AD D S Y S L O G S E R V E R
3. To modify system log server parameters click Modify in Sylog Info tab. Modify Syslog Server window appears as shown in Figure 127. Click Confirm after modifying the required parameters
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
102 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 127 – M O D I F Y S Y S L O G S E R V E R
4. To delete system log server click Delete as shown in Figure 128.
F I G U R E 128 – D E L E T E SY L O G S E R V E R
END OF STEPS
System log information is added, modified and deleted successfully.
Result
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 103
Short Cut
To view the shortcut on desktop.
NMS client and server must be installed.
To view shortcut on desktop, perform the following step:
Click on Short Cut under Common Configuration tree. Short Cut tab appears as shown in Figure 69. Short Cut tab provides information about shortcuts on desktop, in startup menu and path description.
F I G U R E 129 – S H O R T C U T TAB
END OF STEPS
Shortcuts are viewed successfully on desktop.
Other
To view other tab.
NMS client and server must be installed.
To view other tab, perform the following steps:
1. Click on Other under Common Configuration tree. Other tab provides Basic tab as shown in Figure 130.
Purpose
Preliminary Setup
Steps
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
104 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 130 – OT H E R T AB
2. Click Advance tab to view advance information as shown in Figure 131.
Advance tab provide different platform as follows:
UEP Plate Server
NetNumen Server
UEP Plate Client
NetNumen Client
F I G U R E 131 – AD V AN C E T A B
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 105
3. To modify information double click any parameter of Value in Basic tab. In Advance tab put cursor on the value and click for one time, then value appears in Modify field. Click Modify to change the parameters as shown in Figure 132.
F I G U R E 132 – S AV E OT H E R I N F O R M AT I O N
4. To save advance and basic information click Save. Info dialog box appears as shown in Figure 133. Click OK to finish successfully.
F I G U R E 133 – I N F O D I AL O G B O X
END OF STEPS
Other tab is viewed successfully.
Analog Input Parameters Configuration
To configure analog input parameters.
NMS client and server must be installed.
Result
Purpose
Preliminary Setup
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
106 Confidential and Proprietary Information of ZTE CORPORATION
To configure analog input parameters, perform the following steps:
1. Click on Analog Input Configuration under EPM Configuration tree. Analog Input Configuration tab appears as shown in Figure 158.
F I G U R E 134 – AN AL O G I N P U T P AR AM E T E R S C O N F I G U R AT I O N T AB
2. To add analog input parameter, click Add in Analog Input Configuration tab. Add window appears as shown in Figure 135.
F I G U R E 135 – AD D AN AL O G P AR AM E T E R S
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 107
3. To modify the required parameters, click Modify in Analog Input Configuration tab and click OK after modifying parameters as shown in Figure 136.
F I G U R E 136 – M O D I F Y AN AL O G I N P U T P AR A M E T E R S C O N F I G U R AT I O N T AB
4. To delete analog input parameters click Delete. Information dialog box appears as shown in Figure 137. Click Yes to confirm delete.
F I G U R E 137 – I N F O R M AT I O N
END OF STEPS
Analog input parameters are configured successfully.
Digital Input Parameters Configuration
To configure digital input parameters.
NMS client and server must be installed.
Result
Purpose
Preliminary Setup
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
108 Confidential and Proprietary Information of ZTE CORPORATION
To configure digital input parameters, perform the following steps:
1. Click on Digital Input Configuration under EPM Configuration tree. Digital Input Configuration tab appears as shown Figure 138.
F I G U R E 138 – D I G I T AL I N P U T P AR AM E T E R S C O N F I G U R AT I O N T AB
2. Click Add to add digital input parameter. Add window appears as shown in Figure 139.
F I G U R E 139 – AD D I N P U T D I G I T AL P AR AM E T E R S W I N D O W
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 109
3. To modify the required parameters, click Modify in Digital Input Configuration tab and click Save after modifying parameters as shown in Figure 140.
F I G U R E 140 – M O D I F Y D I G I T AL I N P U T P A R AM E T E R S W I N D O W
4. To delete digital input device click Delete in Digital Input Configuration window. Information dialog box appears, click Yes to confirm delete as shown in Figure 141.
F I G U R E 141 – D E L E T E D I G I T A L I N P U T P AR AM E T E R S
END OF STEPS
Digital input parameters are configured successfully.
Digital Output Parameters Configuration
To configure digital output parameters.
NMS client and server must be installed.
Steps
Purpose
Preliminary Setup
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
110 Confidential and Proprietary Information of ZTE CORPORATION
To configure digital output parameters, perform the following steps:
1. Click on Digital Output Configuration under EPM Configuration tree. Digital Output Configuration tab appear as shown in Figure 142.
F I G U R E 142 – D I G I T AL OU T P U T P AR AM E T E R S C O N F I G U R AT I O N T AB
2. Click Add to add digital input parameter. Add window appears as shown Figure 143.
F I G U R E 143 – AD D OU T P U T D I G I T AL P A R A M E T E R S WI N D O W
Steps
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 111
3. Click Modify to change the desired parameters. Select Device Name, as shown in Figure 144. Click OK to confirm the changes.
F I G U R E 144 – M O D I F Y D I G I T AL OU T P U T P AR AM E T E R S C O N F I G U R AT I O N
4. Click Delete in Digital Output Configuration window. Information dialog box appears, click Yes to confirm delete as shown in Figure 145.
F I G U R E 145 – D E L E T E D I G I T A L OU T P U T P AR AM E T E R S
END OF STEPS
Digital output parameters are configured successfully.
Power Parameters Configurations
To configure power parameters.
NMS client and server must be installed.
To configure power parameters, perform the following steps:
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
112 Confidential and Proprietary Information of ZTE CORPORATION
1. Click on Power Configuration under EPM Configuration tree. Power Configuration tab appear as shown in Figure 146.
F I G U R E 146 – P O W E R P AR A M E T E R S C O N F I G U R AT I O N T A B
2. Click Add in Power Configuration tab. Add window appears as shown in Figure 147.
F I G U R E 147 – AD D P O W E R P AR AM E T E R S W I N D O W
3. Click Modify in Power Configuration. Modify window appears as shown in Figure 148. Click Save after modifying the required parameters.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 113
F I G U R E 148 – M O D I F Y P O W E R P AR AM E T E R S C O N F I G U R AT I O N
4. Click Delete in Power Configuration tab. Information dialog box appears, click Yes to confirm delete as shown in Figure 89.
F I G U R E 149 – D E L E T E PO W E R P AR AM E T E R S
END OF STEPS
Power parameters are configured successfully.
Import (Export) Configuration Data
To import and export configuration data.
NMS client and server must be installed.
To import and export configuration data, perform the following step:
1. Click Import (Export) Configuration under Common Maintenance tree. Import (Export) Configuration Data tab appear as shown in Figure 150.
Result
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
114 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 150 – IM P O R T (E X P O R T ) C O N F I G U R AT I O N D AT A T AB
2. To import the data, click Import Configuration Data radio button then click Import. Save windows appears as shown in Figure 151. Click Open to import the data.
F I G U R E 151 – IM P O R T D AT A W I N D O W
3. To export the data, click Export Configuration Data radio button then click Export. Save windows appears as shown in Figure 152. Click Save to export the data.
Chapter 3 NMS Installation
Confidential and Proprietary Information of ZTE CORPORATION 115
F I G U R E 152 – E X P O R T D AT A W I N D O W
END OF STEPS
Data is imported and exported successfully.
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
116 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 117
C h a p t e r 4
VCS4.3 for Windows
This chapter covers the following topics:
Overview
System Requirements
Installation Preparations
Installation Operating System
Installing VCS HA Software
Test Dual System Hot Backup Software
Overview The main purpose of this chapter is to introduce hardware and software configurations required for dual hot backup NM system. It also introduces the procedures for installing sqlserver2000 database and NM system, and tests on dual hot backup system.
This chapter covers DELL 2600 server and DELL 220 disk array (five hard disks) as an example to introduce NM dual system installation. If other servers and disk arrays are used, divide the disk as needed. The software installation procedures are the same.
Procedures of installing NM dual system are:
Configure Hardware
Install Operating System
Install Dual System Software
Install Database System
Install and Configure NM System
Configure and Test Dual System
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
118 Confidential and Proprietary Information of ZTE CORPORATION
System Requirements The following are the hardware requirements:
1. NM server:
The minimum configuration requirements for NM server are:
Memory: 512M
Three network interfaces. Two interfaces connect to heart beat cable for mutual monitoring. The third one connects to public network cable for providing NM service.
One disk array card for connecting disk array
2. Disk array:
Set the disk in RAID1+0 array. Divide the array into two logical drivers with the same space. Five disks, at least four disks, are required. Four disks are set in RAID1+0 array mode. The fifth one is set to be hot spare, as the backup of the other four disks.
The following are the software requirements:
1. Operating system:
Windows operating system: Win200 Server, Win2003 standard
Patch: SP4 + latest security patch
2. Database system
Database system: SqlServer2000 / SqlServer2003 Enterprise Database
Patch: SP3 and above
3. Dual system software
Dual system software: VCS4.3 for Windows
Patch: If there is the latest VCS4.3 patch, install the latest patch.
4. NM server software
NetNumen N31(V4.2.0)NM server
Installation Preparations This section includes the following:
Hardware
Hardware Connection
Connecting Disk Array
Hardware Requirements
Software Requirements
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 119
Hardware
Two DELL 2600 servers
NETNUMENCLUSTER1 (A): It works as master server
NETNUMENCLUSTER2 (B): It works as slave server
Three network interface cards for each server
One SCSI array card for each server
One DELL220 disk array
It is configured with five hard disks. Each of them has the capacity of 63 G.
Hardware Connection
Figure 153 shows hardware connection.
F I G U R E 153 − D U AL H O T B AC K U P NM S Y S T E M
Disk Array Connections
To connect disk array, perform the following steps:
1. Insert two array cards in PCI slots in system A and system B respectively.
2. Connect SCSI array card to DELL220 disk array with SCSI cable.
V240 dual machine +SE3310 disk array:
SUN V240 dual machine (2*1.28G/2G/2*73G) + SE3310 disk array (5*073G)
The hardware connection is shown in Figure 154.
Connection Steps
Disk Array Connection
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
120 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 154 – D I S K AR R AY C O N N E C T I O N S
Note: Ensure that CH0 and single bus cable is connected properly. Generally, some devices have only one SCSI interface, indicating the connection interface of disk array.
Thick cables are used for SCSI interface and thin cables are used for Ethernet cables.
SUN V2404 has four network cards such as net0, net1, net2 and net3.
Generally, net2 and net3 are used for heartbeat therefore, no need to configure IP addresses.
net0 is used to connect DCN network and net1 is used to connect public network.
Explanation
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 121
These cards communicate with each other through SUN system inner protocols.
Installing Operating System To install NM dual hot backup system VCS4.3 for windows.
Before installing the operating system following preliminary setup needs to be configured:
1. Use DELL OPENMAMAGE SERVER ASSISTANT CD to make a driver programme of disk array card.
2. Close disk array.
3. Insert Win2000 installation disk to install the operating system. Insert disk array driver according to system prompt.
4. The operating system uses NTFS file system. It resides a default directory of disk C.
5. Install the latest security patch of WINDOWS 2000 Server + SP4 +.
6. Install operating systems on both computers. Install relevant patches. Install network card driver.
Note: If the operating system is Windows 2003, install Windows Server 2003 Standard. Some VCS Licenses do not support Windows Server 2003 Enterprise.
Tips: Use the installation disk the factory provides to install the operating system. For instance, use Smartstart to install the operating system for HP computer. Follow prompts to install the operating system and disk array start programme.
This section includes the following:
Dividing Disk Array
Setting Network
Setting Domain
Purpose
Preliminary Setup
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
122 Confidential and Proprietary Information of ZTE CORPORATION
Dividing Disk Array
To divide disk array.
Take DELL220 disk array (five disks) as an example.
To divide the disk array, perform the following steps:
1. Configure disk array.
Enable disk array. Restart NETNUMENCLUSTER1. Press ctrl + m to enter BIOS configuration. Select SCSI array card 4/DC. Select config/new config.
2. Divide disk array in RAID1+0 mode.
i. Divide four disks in RAID1+1 mode. Set the fifth disk to be hot spare, which is the backup of other four disks.
ii. Configure RAID1+0 mode.
First, configure two of the four disks to be RAID1 mirror mode. Then, configure them to be RAID0 mode.
3. Create two logical drivers on the disk array.
One is for sqlserver database file. The other is for NM server programmes. Both logical drivers have the same space, occupying half of the disk array.
4. Start NETNUMENCLUSTER2.
Press ctrl + m. Enter BIOS configuration. Select SCSI array card 4/DC. Select config. Identify the disk array configuration again. Then exit BIOS. Start the system.
Note: For disk arrays of other models, follow steps below to divide the disk array.
Divide disk array in RAID1+0 mode.
Create two logical drivers on RAID1 + 0.
END OF STEPS
The disk array is divided successfully.
Configuring Network
To configure the network.
The public network card IP address for NETNUMENCLUSTER1 is 10.40.88.44 (the master DNS points to 127.0.0.1.). The public network card IP address for NETNUMENCLUSTER2 is 10.40.88.139 (the master NDNS points to 10.40.88.44.).
Purpose
Steps
Result
Purpose
Introduction
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 123
To configure the network, perform the following steps:
1. Configure service connection.
Create Public Connection in network and dialing connection in control panel. Right click on Property. Enter TCP/IP configuration. Set IP address and DNS.
2. Configure heartbeat connection.
Create Heartbeat Connection in network and dialing connection in control panel. Right click on Property. Do not select Client for Microsoft Network, File and Print Sharing for Microsoft Networks and Internet Protocol (TCP/IP) as shown in Figure 155.
F I G U R E 155 − C O N F I G U R I N G H E AR T B E AT C O N N E C T I O N
3. Configure host file
Add host names and IP addresses to host files of both computers.
END OF STEPS
The network is connected.
Steps
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
124 Confidential and Proprietary Information of ZTE CORPORATION
Configuring Domain
To configure one computer as master domain server and the other as the backup domain controller.
Main Domain
Configure NETNUMENCLUSTER1 to be master domain controller.
To configure the master domain, perform the following steps:
1. Open configuration server guide on NETNUMENCLUSTER1, as shown in Figure 156 or execute dcpromo command. Create Directory Tree or Child Domain window appears as shown in Figure 157.
F I G U R E 156 − C O N F I G U R AT I O N S E R V E R GU I D E
Purpose
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 125
F I G U R E 157 − C R E AT I N G D I R E C T O R Y TR E E O R S U B -T R E E
2. Select Create a new domain tree and click Next. New Domain Name window appears as shown in Figure 158.
F I G U R E 158 − S P E C I F Y I N G N E W D O M AI N N AM E
3. Enter the full DNS domain name. Here, it is ZTEDOMAIN. Click Next. Database and Log File Locations window appears as shown in Figure 159.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
126 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 159 − S E T T I N G D AT AB AS E AN D L O G F I L E LO C AT I O N
4. Select default values for database location and log location. Click Next. Confirm DNS Configuration window appears as shown in Figure 160.
F I G U R E 160 − C O N F I R M I N G DNS C O N F I G U R AT I O N
5. Click OK. Configure DNS window appears as shown in Figure 161.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 127
F I G U R E 161 − C O N F I G U R I N G DNS
6. Select Yes, install and configure DNS on this computer (recommended). Click Next. Permissions window appears as shown in Figure 162.
F I G U R E 162 − P E R M I S S I O N S
7. Select Permissions compatible with pre-Windows 2000 servers. Click Next. Specify Administrator Password window appears as shown in Figure 163.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
128 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 163 − S P E C I F Y I N G AD M I N I S T R AT O R P AS S W O R D
8. Input directory service resumption password. Click Next. Configuring Active Directory… window appears as shown in Figure 164.
F I G U R E 164 − C O N F I G U R I N G AC T I V E D I R E C T O R Y
9. When configuration is complete, the final window appears as shown in Figure 165.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 129
F I G U R E 165 − C O M P L E T I N G T H E AC T I V E D I R E C T O R Y IN S T AL L AT I O N W I Z AR D
10. Click Finish to close installation wizard. The system prompts to restart windows as shown in Figure 166.
F I G U R E 166 − P R O M P T O F RE S T AR T I N G S Y S T E M
11. Click Restart Now to restart Windows.
END OF STEPS
NETNUMENCLUSTER1 is updated to be master domain server.
Backup Domain
Configure NETNUMENCLUSTER1 as the backup domain server.
To configure the backup domain, perform the following steps:
1. Run the dcpromo command on NETNUMENCLUSTER2. Welcome window appears as shown in Figure 167.
Result
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
130 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 167 − W E L C O M E I N T E R F AC E
2. Click Next. Domain Controller Type window appears as shown in Figure 168.
F I G U R E 168 − D O M AI N C O N T R O L L E R TY P E
3. Select Additional domain controller for an existing domain. Click Next. Network Credentials window appears as shown in Figure 169.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 131
F I G U R E 169 − N E T W O R K C R E D E N T I AL S
4. Input the password. Click Next to add NETNUMENCLUSTER2 to the main domain controller.
END OF STEPS
NETNUMENCLUSTER2 is set to be backup domain controller.
Installing VCS HA Software To install VCS HA software.
To install VCS HA software, perform the following steps:
1. Insert VCS4.3 for Windows install disk. Select product to install window appears as shown in Figure 170.
Result
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
132 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 170 − S E L E C T P R O D U C T T O IN S T A L L
2. Select Storage Foundation HA 4.3 for Windows. Select install type window appears as shown in Figure 171.
F I G U R E 171 − S E L E C T I N S T A L L TY P E
3. Select Complete/Custom. License window appears as shown in Figure 172.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 133
F I G U R E 172 − L I C E N S E
4. Input license key. Click Add button. Then, click Next. Options Selections 1 window appears as shown in Figure 173.
F I G U R E 173 − OP T I O N S S E L E C T I O N S 1
If there is only one heartbeat network card on the computer, select VxCache only.
If there are two heartbeat network cards on the computer, select VxCache, DMP under Dynamic Multipathing as shown in Figure 174.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
134 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 174 − OP T I O N S S E L E C T I O N S 2 (W I T H T W O H E AR T B E AT N E T W O R K C AR D S )
Note: Sometimes, Dynamic Multipathing option is grayed due to VCS licence limitation. Select VxCache only.
5. Click Next and Options Selections 3 window appears as shown in Figure 175.
F I G U R E 175 − OP T I O N S S E L E C T I O N S 3
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 135
6. Select VERITAS Cluster Server Database for SQL. Click Next and Options Selections 4 window appears as shown in Figure 176.
F I G U R E 176 − OP T I O N S S E L E C T I O N S 4
7. Select VERITAS Storage Foundation HA 4.3 for Windows (Client Components). Click Next and Computer Selection window appears as shown in Figure 177.
F I G U R E 177 − C O M P U T E R SE L E C T I O N
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
136 Confidential and Proprietary Information of ZTE CORPORATION
8. Select domain and computers for Cluster. Select install path (Ensure that the install space is larger than 1 G.). Click Next. Validation window appears as shown in Figure 178.
F I G U R E 178 − V AL I D AT I O N
9. Click Next. Install Report window appears as shown in Figure 179.
F I G U R E 179 − I N S T AL L R E P O R T
10. Click Install to start installation. Figure 180 shows installation progress.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 137
F I G U R E 180 − I N S T AL L P R O C E S S
11. When the installation is completed, Install Summary window appears as shown in Figure 181.
F I G U R E 181 − I N S T AL L S U M M AR Y
12. Click Next. Reboot Remote Computers window appears as shown in Figure 182.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
138 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 182 − R E B O O T R E M O T E C O M P U T E R S
13. Select ZTECLUSTER2. Click Reboot. The system gives a prompt about reboot status as shown in Figure 183.
F I G U R E 183 − R E B O O T ST AT U S
14. Click Next. Thank you for using VERITAS Storage Foundation HA 4.3 for Windows window appears as shown in Figure 184.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 139
F I G U R E 184 − TH AN K Y O U F O R U S I N G VERIT AS S T O R A G E FO U N D AT I O N HA 4 .3 F O R W I N D O W S I N T E R F AC E
15. Click Finish to complete the installation. The system gives a prompt dialogue box, asking whether to reboot your local computer now or not, as shown in Figure 185.
F I G U R E 185 − P R O M P T D I AL O G U E B O X , AS K I N G W H E T H E R T O R E B O O T Y O U R L O C AL C O M P U T E R O R N O T
16. Click Yes to reboot the local computer NETNUMENCLUSTER1.
END OF STEPS
VCS software installation on computers is complete.
Creating Disk Array Logical Partition
After installing VCS software, it is required to create disk groups and volumes. That is to divide disk logically and format the disk.
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
140 Confidential and Proprietary Information of ZTE CORPORATION
Creating Disk Group
To create disk groups.
Create the disk group ‘sql-dskgrp’ for sqlserver database.
To create the disk group, perform the following steps:
1. Turn OFF NETNUMENCLUSTER2. Divide the disk array of NETNUMENCLUSTER1.
2. On NETNUMENCLUSTER1, open Start VERITAS VERITAS Enterprise Administrator (VEA). VERITAS Enterprise Administrator window appears as shown in Figure 186.
F I G U R E 186 − VERITAS E N T E R P R I S E AD M I N I S T R AT O R
There are two new disks under localhost – Disks: Harddisk0 and Harddisk2. Both of them are in No signature state.
3. Select Harddisk0. Right click on it. Select Write Disk Signature. Localhost-Write Disk Signature window appears as shown in Figure 187.
Purpose
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 141
F I G U R E 187 − L O C AL H O S T -W R I T E D I S K S I G N AT U R E
4. Select Harddisk0 and Harddisk2. Click OK. Finish writing a signature for the two new disks.
5. Select Disk Group on the VERITAS Enterprise Administrator interface as shown in Figure 186. Right click on it. Select New Dynamic Disk Group. Localhost-New Dynamic Disk Group Wizard 1 window appears as shown in Figure 188. Create a new disk group sql-dskgrp, which is used to store data files of sqlserver database.
F I G U R E 188 − L O C AL H O S T -N E W D Y N AM I C D I S K GR O U P W I Z AR D 1
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
142 Confidential and Proprietary Information of ZTE CORPORATION
6. Select disk-Harddisk0 in disk array. Click Add. Input the disk group name sql-dskgrp. Click Next. Localhost-New Dynamic Disk Group Wizard 2 window appears as shown in Figure 189.
F I G U R E 189 − L O C AL H O S T -N E W D Y N AM I C D I S K GR O U P W I Z AR D 2
7. Click Next and Localhost-New Dynamic Disk Group Wizard 3 window appears as shown in Figure 190.
F I G U R E 190 − L O C AL H O S T -N E W D Y N AM I C D I S K GR O U P W I Z AR D 3
8. Click Finish to finish creating the disk group sql-dskgrp.
END OF STEPS
The disk group ‘sql-dskgrp’ for sqlserver database is created.
Result
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 143
Create the disk group ‘nms-dskgrp’ for NM program.
To create disk group ‘nms-dskgrp’ for NM program, follow the same steps used for creating sql-dskgrp.
Select Harddisk2. The name of the hard group is nms-dskgrp.
After hard disk groups of sql-dskgrp and nms-dskgrp are created, the whole hard disk group is created, as shown in Figure 191.
F I G U R E 191 − C R E AT I N G H A R D D I S K GR O U P C O M P L E T E D
Creating Volume
After creating disk groups, it is required to create volumes for storing shared data, including sql-data for sql server and nms-data for NM programme.
Create sql-data volume.
To create volume, perform the following steps:
1. Select sql-dskgrp under Disk Groups. Right click on it. Select New Volume to create a new logical volume. Localhost-New Volume Wizard 1 window appears as shown in Figure 192.
Steps
Result
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
144 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 192 − L O C AL H O S T -N E W V O L U M E W I Z AR D 1
2. Select sql-dskgrp. Click Next. Localhost-New Volume Wizard 2 window appears as shown in Figure 193.
F I G U R E 193 − L O C AL H O S T -N E W V O L U M E W I Z AR D 2
3. Input sql-data in the volume name text box and 136G in the size box. Click Next. Localhost-New Volume Wizard 3 window appears as shown in Figure 194.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 145
F I G U R E 194 − L O C AL H O S T -N E W V O L U M E W I Z AR D 3
4. Select Assign a drive letter. It is S: here. Click Next. Localhost-New Volume Wizard 4 window appears as shown in Figure 195.
F I G U R E 195 − L O C AL H O S T -N E W V O L U M E W I Z AR D 4
5. Select NTFS for the file system. Select Perform a quick format to format sql-data volume quickly. Click Next. Localhost-New Volume Wizard 5 window appears as shown in Figure 196.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
146 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 196 − L O C AL H O S T -N E W V O L U M E W I Z AR D 5
6. Click Finish to finish creating sql-data volume and format.
END OF STEPS
sql-server volume is created.
Create nms-data volume.
To create and format nms-data volume, perform the same steps used for creating sql-data volume.
Create nms-data volume on nms-dksgrp disk group. The volume size is 140 G. The driver letter is N:.
VCS Software Configuration - Create Cluster
After installing VCS software, it is required to create cluster for both computers.
To create clusters, perform the following steps:
1. Select Start Programme VERITAS VERITAS Cluster Server VCS Configuration Wizard as shown in Figure 197. Welcome window appears as shown in Figure 198.
Result
Steps
Purpose
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 147
F I G U R E 197 − S T AR T I N G VCS C O N F I G U R AT I O N WI Z AR D
F I G U R E 198 − W E L C O M E I N T E R F AC E
2. Click Next. Options window appears as shown in Figure 199.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
148 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 199 − C O N F I G U R AT I O N OP T I O N S
3. Select Cluster Operations. Click Next. Domain Selection 1 window appears as shown in Figure 200.
F I G U R E 200 − D O M AI N S E L E C T I O N 1
4. The system gives out current domains. Select the current one. Click Next. Domain Selection 2 window appears as shown in Figure 201.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 149
F I G U R E 201 − D O M AI N S E L E C T I O N 2
5. Select systems of NETNUMENCLUSTER1 and NETNUMENCLUSTER2. Click Next to discover system, as shown in Figure 202.
F I G U R E 202 − D I S C O V E R I N G S Y S T E M
6. VCW Options window appears as shown in Figure 203.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
150 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 203 − VCW OP T I O N S
7. Select Create New Cluster. Click Next. Cluster Details window appears as shown in Figure 204.
F I G U R E 204 − C L U S T E R D E T AI L S
Cluster Name: Input zte-clu.
Cluster ID: Randomly
Operating System: Select the current operating system.
Select the system to create the cluster.
8. Click Next. Validate Systems window appears as shown in Figure 205.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 151
F I G U R E 205 − V AL I D AT E S Y S T E M S
9. Click Next. NIC Selection window appears as shown in Figure 206.
F I G U R E 206 − N IC S E L E C T I O N
Select the relevant network card as heartbeat card. At least two network cards are required. Use service network card as heartbeat card. Set service network card to be low priority. Select one service network card. Right click on it, as shown in Figure 207.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
152 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 207 − S E T S E R V I C E N E T W O R K C AR D T O B E LO W P R I O R I T Y
10. Click Next. Service Account window appears as shown in Figure 208.
F I G U R E 208 − S E R V I C E AC C O U N T
11. Select Existing user. Select Administrator from the drop-down list. Click Next. Input the domain administrator password. Click OK. Security window appears as shown in Figure 209.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 153
F I G U R E 209 − S E C U R I T Y
12. Use default values. User Name is admin and Password is password. Click Next. Summary window appears as shown in Figure 210.
F I G U R E 210 − S U M M AR Y
13. Click Configure. Use the selected node to create a new cluster. After the new cluster is successfully created, the Finish window appears as shown in Figure 211.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
154 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 211 − F I N I S H
14. Click Finish to exit VERITAS Cluster Configuration Wizard.
END OF STEPS
Cluster is successfully created.
Installing Sqlserver Database It is required to install SQL Server 2000 Enterprise on both NETNUMENCLUSTER1 and NETNUMENCLUSTER2.
Install SQL Server 2000 database on NETNUMENCLUSTER1.
To install SQL Server 2000 database on NETNUMENCLUSTER1, perform the following steps:
1. Click Start VERITAS VERITAS Enterprise Administrator (VEA) menu. Select sql-dskdg disk group. Right click on it and select Import Dynamic Disk Group.
Result: It is possible to access disk S:\ from Explorer of NETNUMENCLUSTER1.
2. Create a sqldata directory in S:\ to locate data files of sqlserver database.
If the Close Window prompt box pops up during sqlserver database installation, open Computer Management Services to disable VERITAS Enterprise Administrator Service.
3. Install SP3 patch or above
Result
Purpose
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 155
4. Uninstall S:\ from NETNUMENCLUSTER1. (Select ztedisk-dg disk group. Right click on it and select Deport Dynamic Disk Group.)
Result: After that, it is impossible to access disk S:\ from Explorer of NETNUMENCLUSTER1.
END OF STEPS
SQL Server 2000 is installed on NETNUMENCLUSTER1.
Install SQL Server 2000 database on NETNUMENCLUSTER2.
To install SQL Server 2000 database on NETNUMENCLUSTER2, perform the following steps:
1. Click Start VERITAS VERITAS Enterprise Administrator (VEA) menu on NETNUMENCLUSTER2. Select sql-dskdg disk group. Right click on it and select Import Dynamic Disk Group.
Result: After that, it is possible to access S:\sqldata from Explorer of NETNUMENCLUSTER2.
2. Change sqldata directory to be sqldata_backup. Then, create a new S:\sqldata. Put database file of NETNUMENCLUSTER2 into the new S:\sqldata directory.
3. Install SQL Server2000 Enterprise database on NETNUMENCLUSTER2. Put sqlserver data files on disk array, namely, S:\sqldata.
Installing SQL Server2000 Enterprise database on NETNUMENCLUSTER2 is the same as that of installing on NETNUMENCLUSTER1.
4. Install SP3 patch or above
5. Delete S:\sqldata_backup directory after installing database and patch on NETNUMENCLUSTER2 successfully.
END OF STEPS
SQL Server 2000 is installed on NETNUMENCLUSTER2.
Configure SQL Server Startup Type
To configure SQL Server startup type to be manual on both computers.
To configure SQL Server startup type, perform the following steps:
1. Double-click the sqlserver icon at the right corner of the computer. SQL Server Server Manager window appears as shown in Figure 212.
Result
Steps
Result
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
156 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 212 − SQL S E R V E R M AN AG E R
2. Do not select Auto start service when OS starts as shown in Figure 213.
F I G U R E 213 − C H AN G I N G SQL S E R V E R AU T O M AT I C S T AR T U P T O B E M AN U AL S T AR T U P
END OF STEPS
SQL startup type is configured successfully.
Installing NMS
Install the NMS on the share disk N, namely N:\NETNUMEN (It is specified while creating volumes).
Install NM program on both computers if NM installation program modifies Windows registry.
Install NM program on either of two computers if NM installation program does not modify Windows registry.
Result
Purpose
Principles
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 157
For NetNumen N31(V4.2.0) series NM programme, install NM program on either of two computers if NM installation program does not modify Windows registry.
To install NMS on the share disk, perform the following steps:
1. Connect nms-dskgrp to VEA. Open VEA. Select nms-dskdg disk group. Right click on it. Select Import Dynamic Disk Group.
Result: It is possible to access N:\ from Explorer of NETNUMENCLUSTER1.
2. Create a NETNUMEN directory on N:\ for NM server program.
3. Install NM server on NETNUMENCLUSTER1.
END OF STEPS
NetNumen N31(V4.2.0) NM program installation is completed.
VCS Software Configuration – Create SqlServer Resource Group
To create a resource group in cluster for SQL Server, implementing the changeover of SQL Server between the two computers.
To create a resource group in cluster, perform the following steps:
1. Select Start Programs VERITAS - VERITAS Cluster Server Database Agent for SQL SQL Configuration Wizard as shown in Figure 214.
F I G U R E 214 − S T AR T I N G VCS M AN AG E M E N T
2. Start VCS management interface. Select Configuration Option window appears as shown in Figure 215.
Steps
Result
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
158 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 215 − S E L E C T C O N F I G U R AT I O N O P T I O N
3. Select MS-SQL Server – Service Group Configuration. Click Next. Service Group Configuration window appears as shown in Figure 216.
F I G U R E 216 − S E R V I C E GR O U P C O N F I G U R AT I O N
4. Input sqlserver-grp in the Service Group Name text box. Select both NETNUMENCLUSTER1 and NETNUMENCLUSTER2
in the Available Cluster Systems box. Click to add them to the Systems in Priority Order box. Click Next. SQL Server Instance Selection window appears as shown in Figure 217.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 159
F I G U R E 217 − SQL S E R V E R I N S T AN C E S E L E C T I O N
5. Do not select Search option. Click Next. Detail Monitoring Configuration window appears as shown in Figure 218.
F I G U R E 218 − D E T AI L M O N I T O R I N G C O N F I G U R AT I O N
6. Do not select any option. Click Next. Registry Replication Path window appears as shown in Figure 219.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
160 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 219 − R E G I S T R Y R E P L I C AT I O N P A T H
7. Input the registry replication path (Generally, the path resides on sql-data volume. Here, it is disk S.). Click Next. Virtual Server Configuration window appears as shown in Figure 220.
F I G U R E 220 − V I R T U AL S E R V E R C O N F I G U R AT I O N
Input following parameters:
Virtual Server Name: It is random.
Virtual IP Address: It is an external virtual IP of SQL server.
Subnet Mask
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 161
Specify the adapter to be used on each system.
8. Click Next. Service Group Summary window appears as shown in Figure 221.
F I G U R E 221 − S E R V I C E GR O U P S U M M AR Y
9. Click Next to create SqlServer resource group. When configuration completes, Configuration Complete window appears as shown in Figure 222.
F I G U R E 222 − C O N F I G U R AT I O N C O M P L E T E
10. Click Finish.
END OF STEPS
Sqlserver resource group configuration in VCS is complete. Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
162 Confidential and Proprietary Information of ZTE CORPORATION
VCS Software Configuration
VCS software configuration includes:
Configure sqlserver resources
Configure NetNumen N31(V4.2.0) NM resources
Upgrade VCS license
Note: Remember to save all modifications after configuring VCS software. Click the third icon on tool bar in the VERITAS Cluster Manager - Java Console window to save the setting.
Configuring sqlserver Resources
To configure sqlserver resources.
Create SQL Server resource group (sqlserver-grp).
To create SQL Server resource group (sqlserver-grp), perform the following steps:
1. Select Start Programs VERITAS - VERITAS Cluster Manager – Java Console as shown in Figure 223. Start the VERITAS Cluster Manager – Java Console interface.
F I G U R E 223 − S T AR T I N G VCS M AN AG E M E N T
2. Select New Cluster in the interface. Connectivity Configuration window appears as shown in Figure 224.
Purpose
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 163
F I G U R E 224 − C O N N E C T I V I T Y C O N F I G U R AT I O N
3. Input 10.40.88.139 in the Host name text box. Click OK. Login window appears as shown in Figure 225.
F I G U R E 225 − LO G I N
4. Input admin as User name and password as password. Click OK. Cluster Explorer window appears as shown in Figure 226.
F I G U R E 226 − C L U S T E R E X P L O R E R
END OF STEPS
As shown in Figure 226, SQL Server service resource group of sqlserver-grp has been added in VCS system.
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
164 Confidential and Proprietary Information of ZTE CORPORATION
Modify sqlserver-grp attributes, including:
AutoStartList
File system resource (MountV)
AutoFileSystem Clean
The value of AutoStartList needs be NETNUMENCLUSETER2, NETNUMENCLUSETER1 in sequence.
If the sequence is wrong, follow the given steps to modify it.
Select sqlserver-grp. Click the Properties tab. Click button behind AutoStartList. AutoStartList window appears as shown
in Figure 227. Click to add the item. Click to delete the item. Modify the sequence to be as shown in Figure 227. Then, click OK.
F I G U R E 227 − AU T O S T AR T L I S T
AutoStartList attribute settings decide on which system the sqlserver-grp resource group (namely, Sqlserver database) runs in priority when both systems are restarted. In this instance, the sqlserver-grp resource group runs on NETNUMENCLUSTER2 in priority. The setting is contrary to AutoStartList attribute setting of NM resource, ensuring that sqlserver database and NM server run on different systems by default.
Set the attribute of file system resource (MountV) to be force unmount.
In the Cluster Explorer window as shown in Figure 226, select
MountV. Click the Properties tab. Click the button on the Force Unmount row. ForceUnmount window appears as
AutoStartList
Steps
Related Information
File System Resource (MountV)
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 165
shown in Figure 228. Select All from the Scalar Value drop-down list. Click OK.
F I G U R E 228 − FO R C E U N M O U N T
Modify AutoFileSystem Clean attribute to be true.
Figure 229 shows the window after modification.
F I G U R E 229 − M O D I F I E D C O N F I G U R AT I O N
END OF STEPS
sqlserver-grp attributes are modified successfully.
Configuring NetNumen N31 NM Resources
To configure NetNumen N31 NM resources.
Configure NM server
Sqlserver database is started normally on either of the two computers.
If it is not started, perform as follows.
AutoFileSystem Clean
Result
Purpose
Prerequisite
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
166 Confidential and Proprietary Information of ZTE CORPORATION
1. Open the VERITAS Cluster Manager - Java Console.
2. Select sqlserver-grp. Right click on it.
3. Select online - NETNUMENCLUSTER1.
4. Start Sqlserver database on NETNUMENCLUSTER1.
5. Mount the NM installation path N:\ NETNUMEN on NETNUMENCLUSTER1. Then, start configuring NM server.
To configure NM server, perform the following steps:
1. Initialize NM server database.
Run N:\NETNUMEN\ums-svr\docs\dbscript\install-db\uep\install.bat to initialize NetNumen N31 NM server database.
2. Perform system configurations on NM server.
For detailed configurations, refer to the Figure 230 section. This section just introduces settings, which have influence on NM server startup, including:
NM server startup parameter
i. Run N:\NETNUMEN\ums-svr\output\tools\configcenter\bin\ run.bat to start NM configuration center tool, as shown in Figure 230.
F I G U R E 230 − N E T N U M E N NM C O N F I G U R AT I O N C E N T E R
ii. Set database IP address connected to NM server. Here, the IP is the floating IP and Sqlserver database, 10.40.88.14. Select test connection and optimization configuration.
iii. Test connection: Test whether it is possible to connect the database normally with current database parameters. If parameters are wrong, the database is not enabled or the database is faulty, the system reports error.
Steps
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 167
iv. Optimization configuration: Optimize the database automatically (mainly for SQL Server database), including set backup mode to be Simple, cleaning database log and compressing log.
Note: Switch Sqlserver database over to NETNUMENCLUSTER2. Start NM configuration center. Select optimization configuration to optimize Sql server database attributes on NETNUMENCLUSTER2.
Server multiple IP addresses setting
For dual systems, the server has multiple IP addresses. It is required to perform the below settings:
Modify the following parameters in the ‘\ums-svr\netnumen\ip\dsl\dsl-base.par\conf\IPMS_param.xml’ file.
<FTP_PARAMETERS
FTPIPAddress="localhost" />
Change FTPIPAddress="localhost to be the NM IP address with which NE can use ftp.
END OF STEPS
It is successful to start NM server on both computers.
Normally, it is successful to start NM server on NETNUMENCLUSTER1. Close the NM server. Uninstall N:\NETNUMEN from NETNUMENCLUSTER1. Mount N:\NETNUMEN to NETNUMENCLUSTER2. It is also successful to start NM server on NETNUMENCLUSTER2.
Add NM server resources in VCS.
Select Start Programs VERITAS VERITAS Cluster Manager Java Console to open VCS management interface as shown in Figure 223.
NM server-related resources contain:
NM server resource group (nms-grp)
Disk group resource (VMDg)
Share disk resource (MountV)
Network interface card resource
Virtual IP resource
NM program resource
To add NM server resources in VCS, perform the following steps:
1. Create NM server resource group (nms-grp).
Result
Follow-up Action
Prerequisite
Resources
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
168 Confidential and Proprietary Information of ZTE CORPORATION
i. Right click on zte-clu as shown in Figure 226. Select Add Service Group. Add Service Group window appears as shown in Figure 231.
F I G U R E 231 − AD D S E R V I C E GR O U P
ii. Input nms-grp in the Service Group name text box. Select NETNUMENCLUSTER1 and NETNUMENCLUSTER2. Check Startup. Click OK. NM resource group (nms-grp) is created as shown in Figure 232.
F I G U R E 232 − C R E AT I N G NM R E S O U R C E GR O U P (N M S -G R P )
iii. Make sure two points:
The sequence of AutoStartList of nms-grp is:
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 169
group nms-grp (AutoStartList = { NETNUMENCLUSTER1, NETNUMENCLUSTER2})
AutoStartList decides on which system nms-grp runs in priority when both systems are restarted. In this instance, nms-grp runs on NETNUMENCLUSTER1 in priority. The setting is contrary to AutoStartList for sqlserver-grp resource, ensuring that sqlserver database and NM server run on different systems by default.
The value for AutoStart is true.
It indicates that when the system is started, nms-grp enabled automatically.
2. Add VMDg resource to nms-grp.
Right click on nms-grp in Creating NM Resource Group (nms-grp) interface as shown in Figure 232. Select Add Resource. Add Resource window appears as shown in Figure 233.
F I G U R E 233 − AD D R E S O U R C E
Select VMDg for Resource Type. Input nms-grp-VMDg in Resource Name. Set the value of DiskGroupName to be nms-dskgrp. Set the value of DGGuid. Select Critical and Enabled. Then, click OK.
DGGuid is the unique ID of disk group in disk array. It is used to identify the disk group. The following steps help to get DGGuid.
i. Select Start Run. Input the cmd command in the Running interface as shown in Figure 234.
Related Information
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
170 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 234 − R U N N I N G
ii. Click OK to open the dos window. Execute the vmgetdrive command in dos window. The VMDriveInfo.txt file is created under the directory (here, it is d:) as shown in Figure 235.
F I G U R E 235 − C R E AT I N G VMD R I V E I N F O.T X T F I L E
iii. Open the d:\ VMDriveInfo.txt file as shown in Figure 236.
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 171
F I G U R E 236 − D : \ VMD R I V E IN F O . T X T
iv. Find the DiskGroup GUID value corresponding to DiskGroup Name = nms-dskgrp disk group. Copy it to nms-grp-VMDg resource as DGGuid value.
Result: The nms-grp-VMDg resource is shown in Figure 237.
F I G U R E 237 − N M S -G R P -VMD G R E S O U R C E
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
172 Confidential and Proprietary Information of ZTE CORPORATION
3. Add share disk resource (MountV).
i. Right click on nms-grp in the nms-grp-VMDg Resource interface as shown in Figure 237.
ii. Select Add Resource. Select MountV for source type. Input nms-grp-MountV for resource name.
iii. Input share disk information of NM program as follows:
MountPath = "N:"
VolumeName = nms-data
VMDGResName = nms-grp-VMDg
ForceUnmount = ALL
AutoFSClean = 1
iv. Click OK.
Result: nms-grp-MountV resource is added as shown in Figure 238, nms-grp-MountV resource is in blue, indicating normal running.
F I G U R E 238 − N M S -G R P -M O U N T V R E S O U R C E
4. Add network interface card resource
Both NM programme and Sqlserver database share the same network interface card. The network interface card resource is added in sqlserver resource group. It is required to create a proxy network interface card resource in nms-grp NM resource group, pointing to sqlserver-grp-NIC. It indicates that NM resource group also uses sqlserver-grp-NIC as own network interface card resource.
Related Information
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 173
i. Right click on nms-grp in the nms-grp-VMDg Resource interface as shown in Figure 237.
ii. Select Add Resource.
iii. Select Proxy for resource type. The resource name is proxy NIC. Select Enable. Edit TargetResName to be sqlserver-grp-NIC, the NIC resource name in sqlserver-grp.
iv. Click OK.
Result: Adding proxy_NIC resource is complete as shown in Figure 239, proxy_NIC resource is in blue, indicating normal running.
F I G U R E 239 − P R O X Y _NIC R E S O U R C E
5. Add virtual IP resource.
This IP resides on the computer which provides NM service. Whatever NM server runs, there is only one IP address.
i. Right click on nms-grp the nms-grp-VMDg Resource interface as shown in Figure 237.
ii. Select Add Resource.
iii. Select IP for resource type.
iv. Input nms_IP for resource name. Property settings for nms_IP are the same as those of sqlserver-grp-IP of sqlserver-grp resource group. For subnet mask and MAC address, refer to sqlserver-grp-IP property setting. Modify IP to be 10.40.88.44, the virtual IP of NM server. Select Enabled.
Properties for IP nms-IP are:
Address = 10.40.88.44
SubNetMask = 255.255.255.0
MACAddress @NETNUMENCLUSTER1 = 00-13-21-B5-F5-0E
MACAddress @NETNUMENCLUSTER2 = 00-14-38-B8-EE-2D
v. Click OK.
Related Information
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
174 Confidential and Proprietary Information of ZTE CORPORATION
Result: Adding nms_IP resource is complete.
6. Add NM program resource.
To implement VCS monitoring and management on NM program, it is required to add NM server to VCS resource group as program resource.
Make preparations below:
i. Configure required parameters. Ensure it is possible to start NM system manually.
ii. Copy N:\NETNUMEN\ums-svr\output\tools\cluster to C:\cluster\cluster. Copy N:\NETNUMEN\ums-svr\output\jdk-windows to C:\cluster\jdk-windows.
iii. Modify NM-related scripts. Modify moni_win.bat and offline_win.vbs under N:\NETNUMEN\ums-svr\output\tools\cluster\ as needed.
For moni_win.bat, modify two paths. Copy jdk-windows to C:\Cluster\jdk-windows. moni_win.bat is under C:\Cluster\cluster. The absolute path for moni_win.bat is:
set JDK_HOME=C:\cluster\jdk-windows
set MONI_HOME=C:\cluster\cluster
For offline_win.vbs, modify NM platform startup absolute path to be executable path. For instance, the NM programme is in N:\NETNUMEN\ums-svr. Modify the path to be:
if ps.executablepath = "N:\NETNUMEN\jdk-windows\bin\java.exe" then
Script for moni_win.bat is:
@echo on
rem -----------------------------------------------------------------------
rem monitor ums Script on cluster for Win32
rem ------------------------------------------------------------------------
set JDK_HOME=C:\cluster\jdk-windows
set MONI_HOME=C:\cluster\cluster
ECHO %MONI_HOME%
%JDK_HOME%\bin\java -classpath %MONI_HOME%;%MONI_HOME%\uep-util-
Purpose
Preliminary Setup
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 175
consoleagent.jar;%MONI_HOME%\uep-psl-cluster.jar com.zte.ums.uep.psl.cluster.ConsoleStatus
ECHO %ERRORLEVEL%
if %ERRORLEVEL% == 1 exit 110
if %ERRORLEVEL% == 0 exit 100
Script for offline_win.vbs is
for each ps in getobject _
("winmgmts:\\.\root\cimv2:win32_process").instances_
If ps.name = "java.exe" Then
if ps.executablepath = "N:\NETNUMEN\jdk-windows\bin\java.exe" then
wscript.echo ps.terminate
end if
End If
'wscript.echo ps.handle&vbtab&ps.name&vbtab&ps.executablepath
Next
iv. Set NM configuration file
For parameters in NM configuration file of ums-svr\platform\psl\ext-service\console\conf\maincontroller.xml, it is recommended to set them to be 1. In this way, the console interface may pop up, for viewing NM status conveniently.
<! – Whether the console has interface or not. The parameter is set to be an integer. 1 – With interface, 0 – Without interface>
<client-type>1</client-type>
Run ums-svr\bin\ console.bat to start the console with interface manually. Select Start automatically while starting the console, as shown in Figure 240. Then, close console. When VCS starts console, console will start NM server automatically.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
176 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 240 − UMS NM P L AT F O R M S E R V E R C O N S O L E
v. Copy NM-related scripts to dual systems.
Perform operations below on both systems.
Create a cluster directory in C:\.
Copy N:\NETNUMEN\ums-svr\tools\cluster to C:\cluster\cluster.
Copy N:\NETNUMEN\ums-svr\jdk-windows to C:\cluster\jdk-windows.
vi. Add NM resource.
Right click on nms-grp in the nms-grp-VMDg Resource interface as shown in Figure 237. Select Add Resource to add NM resource. Select Process for resource type. Input NETNUMEN for resource name as shown in Figure 241.
F I G U R E 241 − AD D NM R E S O U R C E
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 177
InteractWithDesktop: Set InteractWithDesktop to be True.
StartProgram: Set StartProgram to be absolute path of NM starting file, for instance, N:\NETNUMEN\ums-svr\bin\console.bat.
StopProgram: Set StopProgram. The stop script is VBS file. It is required to set command line: cscript /H:Cscript /NOLOGO C:\cluster\cluster\offline_win.vbs.
MonitorProgram: Set MonitorProgram. Monitor programme monitors the absolute path of NM monitor script. Here, it is C:\cluster\cluster\ moni_win.bat.
Select Process show all attribute restartlimit. Set the restart limit to be 3. Start the current system for three times. If it still fails, switch over to another system as shown in Figure 242.
F I G U R E 242 − S E T R E S T AR T L I M I T T O B E 3
Note: For VCS4,2 version, there is no restartlimit attribute.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
178 Confidential and Proprietary Information of ZTE CORPORATION
Result: The configured NM program resource is shown in Figure 243.
F I G U R E 243 − NM P R O G R AM M E R E S O U R C E
Add relationship.
Select nms-grp. Select the Resource tab. Click link to add relations between resources. This relationship chart is very important. VCS decides starting and exiting sequence according to the chart as shown in Figure 244.
F I G U R E 244 − AD D I N G R E L A T I O N S H I P
Test nms-grp, including two items below:
Make sure all resource settings are available after resources are added in nms-grp. If the resource is grey, select it. Right click on it. Select Enable. Check all parameters, Ensure all resources are in Enable status.
Select nm-grp resource. Right click on it. Select online - NETNUMENCLUSTER1 or (NETNUMENCLUSTER2). The NM
Follow-up Action
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 179
system can run on NETNUMENCLUSTER1 (or NETNUMENCLUSTER2). Select nm-grp resource. Right click on it. Select switch to - NETNUMENCLUSTER2 (NETNUMENCLUSTER1). The NM system can switch to another system.
END OF STEPS
NetNumen N31 NM group resources (nms-grp) configuration is complete.
Establish relationship between sqlserver-grp and nms-grp.
To establish the relationship sqlserver-grp and nms-grp, ensuring that NM server can start normally after NM-related resources are started.
To establish relationship between sqlserver-grp and nms-grp, perform the following steps:
1. Select cluster: zte-clu in VCS management interface. Select the Service Group tab as shown in Figure 245.
F I G U R E 245 − S E R V I C E GR O U P
2. Click link. Link Service Groups window appears as shown in Figure 246.
Result
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
180 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 246 − L I N K S E R V I C E GR O U P S
3. Select online global and firm. Click OK.
4. Save configurations.
NOTE: Create a connection line pointing from nms-grp to sqlserver-grp. It indicates that NM resource group relies on database resource group.
END OF STEPS
Configurations on all VCS resources are complete. Figure 247 shows the status when all resources are in normal startup.
F I G U R E 247 − AL L VCS R E S O U R C E S AR E S T AR T E D N O R M AL L Y
Result
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 181
Upgrading VCS License
To update VCS license.
To update the VCS license, perform the following steps:
1. Open the control panel. Select Add/Delete Programs. Find VFSW4.1(Server Components) as shown in Figure 248.
F I G U R E 248 − F I N D I N G P R O G R AM
2. Click Modify. A window for modifying options appears as shown in Figure 249.
F I G U R E 249 − M O D I F Y I N G OP T I O N S
3. Select License Management. Click Next. License window appears as shown in Figure 250.
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
182 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 250 − L I C E N S E I N T E R F AC E
The License interface as shown in Figure 250 shows License of current Cluster. Click the current License to display details of the current license.
4. Input a new License in the Enter a license key: text box. Click Update. The new license is updated. The new license information is displayed.
5. Click Remove to delete the expired License. Click Finish to end the update.
END OF STEPS
VCS license is updated successfully.
Test Dual System Hot Backup Software Test VCS dual system running status for ensuring normal operation. This section includes the following:
Test Single System
Test Dual System
Test Rules for Local Dual Hot Backup System
Test Single System
To test a single system.
Result
Purpose
Chapter 4 VCS4.3 for Windows
Confidential and Proprietary Information of ZTE CORPORATION 183
To test a single system, perform the following steps:
1. Select nms-grp.
2. Right click on it.
3. Select online ZXNMO1CLUSTER1. Resource groups are started in the sequence set in the relationship. Test the running of NETNUMENCLUSTER1 and NETNUMENCLUSTER2.
END OF STEPS
Single system is tested successfully.
Test Dual Systems
To test dual systems.
To test dual systems, perform the following steps:
1. Manual switchover
Run nms-grp on NETNUMENCLUSTER1. Select NETNUMENCLUSTER1. Select the switchover operation. The nms-grp is switched over to NETNUMENCLUSTER2.
2. Automatic switchover when the programme on running node is faulty.
When the programme on node running with resource group is faulty, the system monitors the fault and switches the resource group to the backup node automatically. Simulate a programme fault manually to have a test. For instance, terminate the process of sqlserver database or shut down NM server manually.
3. Automatic switchover when running node is closed.
When the node running with resource group has hardware fault or power problem, the system switches over to backup node automatically. Simulate such a fault manually. For instance, shut down NETNUMENCLUSTER1 when resource group is running on NETNUMENCLUSTER. The resource group will switch over to NETNUMENCLUSTER2 automatically.
END OF STEPS
Dual system is tested successfully.
Test Rules for Local Dual Hot Backup System
Test rules for local dual hot backup system include:
Switch over resource groups manually. It is possible for NM server to have a switchover between two systems.
Steps
Result
Purpose
Steps
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
184 Confidential and Proprietary Information of ZTE CORPORATION
Automatic switchover in faulty status.
Terminate database progress manually. Sqlserver database is switched over to the NM server system. The dual system and NM server works normally.
Terminate NM progress manually. If NM fails to restart for three times, NM is switched to the sql database system. NM server works normally.
Disconnect all service network interfaces manually. The system detects the fault and switches the resource group to another system.
Close node1 which is running sqlserver database. The resource group is switched over to node2 automatically.
Close node1 which is running NM resource group. The resource group is switched over to node2 automatically.
When both systems are restarted simultaneously, sqlserver database and NM server run in different system.
Note: VCS technical support phone: 800-810-9771. Prepare product serial number, which is available on the product certificate.
Confidential and Proprietary Information of ZTE CORPORATION 185
C h a p t e r 5
VCS4.0 for UNIX
This chapter covers the following topics:
Overview
System Installation
Configuring VCS System
NM Dual System Test Rules
System Security
Overview This chapter covers the detailed installation and configuration of NetNumen N31(V4.2.0) dual hot backup system VCS4.0 in Solaris9 operating system. Related contents are as follows:
Solaris9 operating system installation
Configuration requirements of disk array
VCS4.0 installation and configuration
Oracle9.i database installation
NetNumen N31 ( V4.2.0 ) NM server installation and configuration
Dual Hot Backup Configuration Requirements
Hardware and software requirements for NetNumen N31 (V4.2.0) dual hot backup system are as follows:
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
186 Confidential and Proprietary Information of ZTE CORPORATION
Hardware Requirements
NM server
Two UNIX servers with the same model and configurations are required. The minimum configuration requirements are:
Memory: Not less than 1 G
Swap partition equals to the twice of real physical memory.
Three network interfaces: Two interfaces connect to heartbeat cable for mutual monitoring. The third one connects to public network cable for providing NM service.
One disk array card for connecting disk array.
Disk array
Set the disk in RAID1+0 array mode. Five disks are required. Four disks are set in RAID1+0 array mode and the fifth one is set to be hot spare, as the backup of the other four disks.
Data on disk array: Data files of NM server and oracle database, and backup files of NM.
Configure four LUN r66655. Here, take a disk array with 146 G as an instance. Table 19 lists the division of disk.
T AB L E 19 − D I S K P AR T I T I O N
LUN No.
Mount Path Function Min. Value
Value
1 /export/home/oracle/oradata
Oracle database data files
≥40 G 45 G
2 /netnumen Install NM system server program
≥15 G 20 G
3 /export/home/backup
Data file backup ≥15 G 20 G
4 /export/home/ftp Save traffic statistic files
≥40 G 60 G
Note: The number of LUNs and size of each LUN depend on system requirements. For example, both database file partition and NM server file partition depend on the scale of on-site NM and database scale.
If it is required to install other programmes, which is under VCS management, it is possible to add the number of LUN. Confirm the number of LUN as required.
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 187
Software Requirements
Operating system software
Solaris9
Operating system patch: The latest 9_Recommended
Dual system backup software
VCS4.0
If there is the latest VCS patch, install the latest patch.
Database software
Oracle9.2 + Oracle database patch
Install Oracle database programme in home region, for instance, /export/home/oracle.
Put Oracle data file on disk array. The mount point is /export/home/oracle/oradata, for share data resource.
NM system software
Install NM server software on disk array. The mount point is /netnumen.
Put NM data backup directory on disk array. The mount point is /export/home/backup.
System Installation Installing NM dual hot backup system VCS4.0 for UNIX include the following:
Solaris9 operating system installation
Disk array partition
Setting network
Oracle database installation
VCS4.0 installation
Solaris9 Operating System Installation
To install Solaris9 operating system.
Use local CD-ROM driver to Install Solaris software on SPARC-based single system. Graphic operating interfaces are available during installation.
Purpose
Preliminary Setup
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
188 Confidential and Proprietary Information of ZTE CORPORATION
Install Solaris9 system on both hosts. Take host names as netnumencluster1 and netnumencluster2.
To install Solaris9 operating system, perform the following steps:
1. Power ON the host. Insert CD-ROM SOLARIS SOFTWARE 1 of 2. Enter OK status. (If Solaris is installed before, press Stop + A while starting the system.).
2. Input the boot cdrom command after the DOS prompt. Press Enter. The system is restarted automatically.
3. Select language: English
4. Select area: English
5. Solaris installation program. Continue.
6. Identify the system. Continue.
7. Select Online for Network connectivity. Continue.
8. Select No for DHCP. Continue.
9. Select the default for network interface. Generally, it is eri0. Continue.
Note: The list changes with various built-in network card types, such as eri, ce and hme. If eri0 exists in the list, there is eri network card. If ce0 exists, there is ce network card. If hme0 exists, there is hme network card.
Record available network cards for later use.
10. Input netnumencluster1 as the first host name. Continue.
11. Input 10.61.94.3 as the IP address of netnumencluster1. Continue.
12. Select Yes for Subnet Continue.
13. Input 255.255.255.0 as network mask. Continue.
14. Select None for IPV6. Continue.
15. Select None for default route. Continue.
16. Confirm information. Continue.
17. Select None for security policy. Continue.
18. Confirm information. Continue.
19. Select None for name service. Continue.
20. Confirm information. Continue.
21. Select time zone, continue.
22. Select country and region. Continue.
23. Set date and time. Continue.
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 189
24. Confirm information. Continue.
25. Select Initial for Solaris interactive installation program.
26. Select Standard for installation mode of Solaris interactive installation program.
27. Select geographical region. Continue.
28. Select Entire Distribution plus OEM support 64-bit for software. Continue.
29. Select c1t0d0 for disk.
Select c1t0d0 for boot disk. Click OK.
Select Configure EEPROM again.
30. Do not select 'Save data’. Continue.
31. Auto format file system. Continue.
32. The File System and Disk Format interface pops up. Select the disk. Divide the disk.
Table 20 lists the c1t0d0 disk. Here, take the disk of 60 G as an example.
T AB L E 20 − C1 T 0 D 0 D I S K PAR T I T I O N
Partition No. Mount to Size (G)
0 / 15 G
1 swap Twice of host memory
2 overlap Overlap indicates the size of the whole disk. Do not modify it.
3 /var 5 G
4 - Reserve one partition and 500 M space for creating MetaDB while disk mirror.
5 - -
6 - -
7 /export/home The rest space, approximately 44 G
33. Do not install remote file system. Continue.
34. Summary table for confirming boot system, language and hardware setting. Continue.
35. Alarm (It is a system prompt about disk space including unused disk space. Leave it.). Click OK.
36. Select Auto Reboot to start installation.
37. Wait for system installation and reboot.
38. Set hyper user’s password (root password). Input nms@zte. Press Enter. Input the password again for confirmation.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
190 Confidential and Proprietary Information of ZTE CORPORATION
39. Select CD/DVD for medium. Click Next.
40. Insert the CD of SOLARIS 9 SOFTWARE 2 of 2. Click OK to start installation.
41. Installation summary. Click Next.
42. Select CD/DVD for medium. Click Next.
43. Insert the CD of SOLARIS 9 LANGUAGES. Click OK.
44. Click Install to start installation.
45. Installation summary. Click Exit.
46. Click Reboot.
47. Reboot the system.
Note:
Select zh.GBK while logs on to Solaris.
Select CDE for the first login.
END OF STEPS
Solaris9 operating system is successfully installed.
Installing Latest Solaris9 Patch
To install the latest patch for Solaris9 system.
Download the patch from the SUN company website or ask one from the provider.
Generally, the recommended patch is 9_Recommended.zip.
To install the latest patch for Solaris9 system, perform the following steps:
1. Upload Solaris9 patch.
i. Log on to SUN server as root user.
ii. If the patch file resides on a computer with Windows operating system, transfer the file to SUN server in FTP. Remember to use binary mode file transmission.
Modify /etc/ftpd/ftpusers file on SUN server. Note the root line with #, release the ftp right of root user.
Run FTP command on Windows system.
Input root user’s user name and password.
Input bin behind the ftp> prompt. The transmission mode is changed to be binary mode.
Use the put command under ftp> prompt to transfer the patch file to the root directory of SUN server.
Result
Purpose
Preliminary Setup
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 191
2. Install Solaris9 patch: 9_Recommended
i. Decompress the patch file of 9_Recommended.zip on SUN server.
Ensure root user has the right of reading the file.
Depress the patch # unzip 9_Recommended.zip as root user. Press Enter. A directory with 9_Recommended will be created after depression.
ii. Enter the directory of 9_Recommended. Press return key.
iii. Install the patch packet as root user: # ./install_cluster. Press Enter.
NOTE: There is a point before /.
iv. When the system prompts “Whether to install or not”, input y. Press Enter. The auto installation starts. The installation may last for one to four hours.
Note: Generally, if SCSI disk array is used, install the patch 9_Recommended.zip from SUN. If fiber array is used, install SUNWsan patch additionally. The array CD contains the patch.
END OF STEPS
Solaris9 patch is successfully installed.
Disk Array Partition
Disk array Partition includes the following:
Hardware Connection
Requirements
SUN 3310 Disk Array Partition
Dividing SUN A1000 Disk Array
Hardware Connection
Figure 251 shows hardware connection. Host A refers to netnumencluster1. Host B refers to netnumencluste2.
Connect Host A and Host B with two crossover cables used as heartbeat cables. Both hosts use heartbeat cables to monitor the opposite status. Connect SCSI cables to connect disk arrays. Both hosts access to Internet via network interface.
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
192 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 251 − D U AL H O T B AC K U P NM S Y S T E M
Requirements
Take SUNA1000 disk array as an example to divide disk array. If disk arrays of other models are used, follow the below given requirements to divide the disk array.
1. Divide disk array in RAID1+0 mode.
Divide four disks in RAID1+0 mode. Set the fifth disk to be global hot spare, which is the backup of other four disks.
2. Establish four LUN on RAID1 + 0 array.
One LUN saves data file of oracle database. Second LUN saves NM server program. Third LUN saves backup NM data. The fourth one saves traffic files.
Divide disk spaces of four logical drivers as needed.
Table 21 lists the four LUN disk spaces. Take the disk space of 146 G as an instance.
T AB L E 21 − D I S K P AR T I T I O N
LUN
No.
Mount to Function Min. Value
Value
1 /export/home/oracle/oradata
Oracle database data files
≥40 G 45 G
2 /netnumen Install NM system server program
≥15 G 20 G
3 /export/home/backup
Data file backup ≥15 G 20 G
4 /export/home/ftp Save traffic statistic files
≥40 G 60 G
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 193
Note:
The number of LUNs and size of each LUN depend on system requirements. For example, both database file division and NM server file division depend on the scale of on-site NM and database scale.
If it is required to install other programmes, which is under VCS management, it is possible to add the quantity of LUN. Confirm the number of LUNs as required.
3. Format the space on disk array to be file system.
SUN 3310 Disk Array Partition
To divide SUN 3310 disk array. If other disk arrays are used, please refer to the attached disk array management guide.
To divide the disk array, perform the following steps:
1. Set scisi ID.
Usually, 3310 has a controller. The default configuration is suggested. After rebooting computer, press Stop + A, execute below commands to detect whether the system can identify SCSI card.
OK> probe-scsi-all
If system identifies SCSI card successfully, it shows the usage of disk array. If not, the system gives a prompt.
OK> printenv, display each equipment situation and SCSI ID number.
After establishment, execute boot –r command in OK status. Reboot the system; the disk array can start running if SCSI is in normal status.
2. Configure disk array.
i. Connect disk array to host using the attached console cable. Input tip hardwire. Select Terminal (VT100 Mode). Enter configuration interface.
ii. Configure disk array’s controller.
View and edit channels-select 1 and 3 in sequence -view and edit scsi id. Add master or slave controller. Do not use the same id. Configure each interface with one master and one slave controller.
iii. Divide Disk Array.
View and edit logical drive-create logical drive. Select four hard disks and divide them as RAID + 0.
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
194 Confidential and Proprietary Information of ZTE CORPORATION
View and edit drives-add global spare drive. The fifth disk is set to be hot spare, as the backup of the other four disks.
iv. Establish LUN.
View and edit logical drives-partition logical drive. Divide disk space into 45 G, 20 G, 20 G, 60 G in sequence.
v. MAP Disk.
View and edit host luns, map four LUNs separately.
vi. Modify /kernel/drv/sd.conf file and the target (Use the format command to view). For example, if disk array is c2t2d0, add the following contents into the file:
name="sd" class="scsi" class_prop="atapi"
target=2 lun=1;
name="sd" class="scsi" class_prop="atapi"
target=2 lun=2;
name="sd" class="scsi" class_prop="atapi"
target=2 lun=3;
vii. Execute #reboot -- -r to reboot system.
NOTE: Use “esc” to confirm operation.
3. Format disk array.
i. After dividing disk array, execute the following commands to identify the disk.
#drvconfig
#disks
Or #devfsadm –C
ii. Use the format command to view disk array.
It displays that c1t0d0 is a local disk. The other four are four LUNs of disk array. In this instance, the available space for disk array is 146 GB.
45 GB for c3t0d0, for saving data files of Oracle database
20 GB for c3t0d1, for saving NM server program
20 GB for c3t0d2, for saving NM backup data
60 GB for c3t0d3, for saving NM traffic statistics files
Input the following black commands.
oot@ zxnm01cluster1 # format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0110ff591,0
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 195
1. c3t0d0 <Symbios-StorEDGEA1000-0301 cyl 3994 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
2. c3t0d1 <Symbios-StorEDGEA1000-0301 cyl 19998 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
3. c3t0d2 <Symbios-StorEDGEA1000-0301 cyl 49749 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
4. c3t0d3 <Symbios-StorEDGEA1000-0301 cyl 59712 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
Specify disk (enter its number): 1
selecting c3t0d0
[disk formatted]
Warning: Current Disk has mounted partitions.
FORMAT MENU:
disk - select a disk
type - select (define) a disk type
partition - select (define) a partition table
current - describe the current disk
format - format and analyze the disk
repair - repair a defective sector
label - write label to the disk
analyze - surface analysis
defect - defect list management
backup - search for backup labels
verify - read and display labels
save - save new disk/partition definitions
inquiry - show vendor, product and revision
volname - set 8-character volume name
!<cmd> - execute <cmd>, then return
quit
format> p
PARTITION MENU:
0 - change `0' partition
1 - change `1' partition
2 - change `2' partition
3 - change `3' partition
4 - change `4' partition
5 - change `5' partition
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
196 Confidential and Proprietary Information of ZTE CORPORATION
6 - change `6' partition
7 - change `7' partition
select - select a predefined table
modify - modify a predefined partition table
name - name the current table
print - display the current table
label - write partition map and label to the disk
!<cmd> - execute <cmd>, then return
quit
partition> p
Current partition table (original):
Total disk cylinders available: 19998 + 2 (reserved cylinders)
Part Tag Flag Cylinders Size Blocks
0 root wm 0 - 127 128.00MB (128/0/0) 262144
1 swap wu 128 - 255 128.00MB (128/0/0) 262144
2 backup wu 0 -4398 43.05GB (19998/0/0) 40955904
3 unassigned wm 0 0 (0/0/0) 0
4 unassigned wm 0 0 (0/0/0) 0
5 unassigned wm 0 0 (0/0/0) 0
6 usr wm 256 – 4398 43.03GB (19742/0/0) 40431616
7 unassigned wm 0 0 (0/0/0) 0
iii. Use the newfs command to establish the format disk array to be file system.
#newfs /dev/dsk/c3t0d0s2
newfs: construct a new file system /dev/ dsk / c3t0d0s2:
(y/n)? y
…..
Format the other three partitions (c3t0d1s2,c3t0d2s2,
c3t0d3s2 ) in the same way.
Disk array is available after formatting.
END OF STEPS
SUN 3310 disk array partition is done successfully. Result
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 197
Dividing SUN A1000 Disk Array
Take SUNA1000 disk array as an example to divide disk array. If disk arrays of other models are used, the required disk array management software and partition may be different from those for SUNA100 disk array. Please refer to attached disk array management guide.
To divide disk array.
To divide disk array, perform the following steps:
1. Set scsi ID.
i. Connect hardware as shown in Figure 251 . Start up the host. Set the serial number of SCSI card. Set one host with default value 7 and the other to be 6. Restart both hosts to validate the setting.
ii. Press Stop + A. Execute below commands to detect whether the system can identify SCSI card.
OK> probe-scsi-all
If it is successful to identify SCSI card, the system shows the usage of disk array. If not, the system gives a wrong prompt.
OK> printenv, displaying system information and SCSI ID.
If SCSI ID numbers of both hosts are in collision to each other, use the command below to set SCSI ID.
OK>setenv scsi-initiator-id 6, setting SCSI ID to be 6.
iii. Use the boot –r command to reboot the system.
Result: The disk array can be in normal operation if SCSI is normal.
2. Install disk management software – RAID MANAGER
RAID MANAGER is a kind of software for managing disk array, developed by SUN. The function of RAID MANAER is to perform configuration and management on disk array of SCSI interface, such as A1000/D1000. For different disk array, the management software is various. For disk arrays with other models, refer to attached disk array management software.
It is very easy to install RAID MANAGER. Key points are:
i. Use the #/usr/sbin/pkgadd –d /cdrom/cdrom0/Product command to install RAID MANAGER.
Follow system prompts to implement installation.
ii. Use #reboot -- -r command to restart the system.
Introduction
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
198 Confidential and Proprietary Information of ZTE CORPORATION
3. Dividing Disk Array
Divide four disks in RAID1+0 mode. Set the fifth disk to be global hot spare. Divide four LUN.
4. Format disk array.
i. Execute the #drvconfig and #disks commands to identify the disk.
ii. Use the format command to view disk array.
It displays that c1t0d0 is local disk. The other four are four LUN of disk array. In this instance, the available space for disk array is 146 G.
45 G for c3t0d0, for saving data files of oracle database
20 G for c3t0d1, for saving NM server program
20 G for c3t0d2, for saving NM backup data
60 G for c3t0d3, for saving NM traffic statistics files
root@ netnumencluster1 # format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/pci@9,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0110ff591,0
1. c3t0d0 <Symbios-StorEDGEA1000-0301 cyl 3994 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
2. c3t0d1 <Symbios-StorEDGEA1000-0301 cyl 19998 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
3. c3t0d2 <Symbios-StorEDGEA1000-0301 cyl 49749 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
4. c3t0d3 <Symbios-StorEDGEA1000-0301 cyl 59712 alt 2 hd 64 sec 64>
/pseudo/rdnexus@4/rdriver@5,0
Specify disk (enter its number) 1
selecting c3t0d0
[disk formatted]
Warning Current Disk has mounted partitions.
FORMAT MENU:
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 199
disk - select a disk
type - select (define) a disk type
partition - select (define) a partition table
current - describe the current disk
format - format and analyze the disk
repair - repair a defective sector
label - write label to the disk
analyze - surface analysis
defect - defect list management
backup - search for backup labels
verify - read and display labels
save - save new disk/partition definitions
inquiry - show vendor, product and revision
volname - set 8-character volume name
!<cmd> - execute <cmd>, then return
quit
format> p
PARTITION MENU:
0 - change `0' partition
1 - change `1' partition
2 - change `2' partition
3 - change `3' partition
4 - change `4' partition
5 - change `5' partition
6 - change `6' partition
7 - change `7' partition
select - select a predefined table
modify - modify a predefined partition table
name - name the current table
print - display the current table
label - write partition map and label to the disk
!<cmd> - execute <cmd>, then return
quit
partition> p
Current partition table (original):
Total disk cylinders available: 19998 + 2 (reserved cylinders)
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
200 Confidential and Proprietary Information of ZTE CORPORATION
Part Tag Flag Cylinders Size Blocks
0 root wm 0 - 127 128.00MB (128/0/0) 262144
1 swap wu 128 - 255 128.00MB (128/0/0) 262144
2 backup wu 0 -4398 43.05GB (19998/0/0) 40955904
3 unassigned wm 0 0 (0/0/0) 0
4 unassigned wm 0 0 (0/0/0) 0
5 unassigned wm 0 0 (0/0/0) 0
6 usr wm 256 - 4398 43.03GB (19742/0/0) 40431616
7 unassigned wm 0 0 (0/0/0) 0
iii. Use the newfs command to create the disk array to be file system.
#newfs /dev/dsk/ c3t0d0s2
Newfs: construct a new file system /dev/ dsk / c3t0d0s2: (y/n)? y
…..
END OF STEPS
The disk array is available.
Format the other three partitions in the same way.
Setting Network
To set the network.
Use both hme0 and hme1 as heartbeat network interfaces. Use Eri0 as service network interface of public network.
Note: Perform this operation on both systems.
To set the network, perform the following steps:
1. Modify the /etc/profile file.
Use ‘vi’ or text editor to add contents below at the end of the ‘/etc/profile’ file.
PATH=/sbin:/usr/sbin:/opt/VRTSvcs/bin:$PATH
Result
Follow-up Action
Purpose
Preliminary Setup
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 201
export PATH (Press Enter to go to the next line.)
2. Hosts allocation
The host names are: netnumencluster1 and netnumencluster2
3. Public network interface card’s IP address allocation
Use eri0 as public network interface card. Allocate IP addresses as follow:
10.61.94.3: netnumencluster1
10.61.94.30: netnumencluster12
Floating IP address
To ensure that the same IP is used wherever oracle database runs, it is recommended to use floating IP. In this way, it is possible for oracle database to run transparently on dual systems.
To ensure that the same IP is used wherever NM server runs, it is recommended to use floating IP too. In this way, it is possible to provide transparent services to NM client.
Floating IP is set on the network interface card of public network because it need provide external services.
Floating IP address for oracle database is 10.61.94.253. The server name is oracledbsvr.
Floating IP address for NM server is 10.61.94.254. The server name is nmssvr.
4. Check and modify contents of the ‘/etc/hosts’ file.
After modification, the ‘/etc/hosts’ file of netnumencluster1 has following contents:
127.0.0.1 localhost
10.61.94.3 netnumencluster1 loghost
10.61.94.30 netnumencluster2 # (It is for accessing the other host while installing VCS.)
10.61.94.253 oracledbsvr
10.61.94.254 nmssvr
After modification, the ‘/etc/hosts’ file of zxnm02cluster1 has following contents:
127.0.0.1 localhost
10.61.94.30 netnumencluster2 loghost
10.61.94.3 netnumencluster1 # (It is for accessing the other host while installing VCS.)
10.61.94.253 oracledbsvr
10.61.94.254 nmssvr
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
202 Confidential and Proprietary Information of ZTE CORPORATION
5. Edit contents of network interface card file
The logical name corresponding to network interface card name may vary due to different location. Sometimes, it is required to configure a temporary IP address to confirm the logical name of network interface card.
Execute the prtdiag command to view whether contents of hme, ce and eri exist. Confirm the network interface card type of public network, such as hme, ce and eri. The file names may various according to different external network interface card type.
Solaris9 Operating System Installation section describes the built-in network interface card type. If both built-in network interface card and external network interface card are hme, their file names are hostname, ce0 and hostname, ce1 respectively. If external network interface cards are eri, their file names are hostname, eri0 and hostname, eri1 respectively. If network interface cards of other types are used, change eri according to the relevant network interface card types.
Network interface card file on netnumencluster1
The /etc/hostname.eri0 on netnumencluster1 must contain the contents as below:
netnumencluster1
Network interface card file on netnumencluster2
The /etc/hostname.eri0 on netnumencluster2 must contain the contents as below:
netnumencluster2
6. Edit contents of the ‘/.rhosts’ file
For the ‘/.rhosts’ file of both hosts, the content is the ‘+’ mark. If there the ‘/.rhosts’ file does not exist, create it.
+ (Press the Enter key to another line.)
7. Check the contents of the ‘/etc/netmasks’ file
The ‘/etc/netmasks’ file is the subnet mask of the host: 10.61.92.0 255.255.252.0
8. Check the contents of the ‘/etc/ defaultrouter’ file.
The ‘/etc/defaultrouter’ file is the gateway setting of the host. Add the gateway on both hosts. If the ‘/etc/defaultrouter’ file does not exist, create it.
root@ netnumencluster2 # cat /etc/defaultrouter
10.61.95.254
Use #route add default 10.61.95.254 command to add the gateway.
9. Restart the system
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 203
Use root@ netnumencluster1# init 6 command to restart netnumencluster1 and netnumencluster2.
END OF STEPS
Network is successfully set.
Use commands below to check:
Use #hostname command to check the host name.
Use #ifconfig –a command to check IP address. There need be one IP address for hme0, hme1 and eri0 respectively.
Installing Oracle Database
Installing oracle database on both hosts include the following:
Preparations before Installation
Installing Oracle Database on netnumencluster1
Installing Oracle Database on netnumencluster2
Modifying Oracle Database Service IP as Floating IP
Preparations before Installation
1. Create Oracle database mount point, for saving data files of database.
Create a /export/home/oradata directory as oracle user, for saving data files of Oracle database.
#su – oracle
$ pwd
/export/home/oracle
$mkdir oradata
2. Mount the data partition of oracle database on disk array, for saving oracle data file.
#mount /dev/dsk/c3t0d0s2 /export/home/oracle/oradata
Then, use tdf –k command to see the /export/home/oracle/oradata directory on netnumencluster1.
NOTE: Perform operations described in this section only on one host, such as netnumencluster1.
Result
Follow-up Action
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
204 Confidential and Proprietary Information of ZTE CORPORATION
Installing Oracle Database on netnumencluster1
To install oracle database on netnumencluster1.
To install oracle database on netnumencluster1, perform the following steps:
1. Install oracle database.
Install oracle and relevant patches on netnumencluster1. For details, refer Installing Oracle 9i section.
NOTE: Put oracle database file on disk array. That is to input /export/home/oracle/oradata on the Database File Location interface.
2. Oracle database backup
i. Uninstall oracle data files from disk array.
#umount/export/home/oracle/oradata
#cd/export/home
ii. Back up database /export/home/oracle
#tar –cvf oracle.tar /export/home/oracle
iii. Back up database /export/home/ apache
#tar –cvf apache.tar /export/home/ apache
END OF STEPS
Oracle database on netnumencluster1 is installed successfully.
Installing Oracle Database on netnumencluster2
To install oracle database on netnumencluster2.
It is unnecessary to re-install oracle database on netnumencluster2. Actually, it is to perform relevant configurations on netnumencluster2 and copy database files from netnumencluster1 to netnumencluster2.
To install oracle database on netnumencluster2, perform the following steps.
1. Set UNIX core parameters on Oracle9i.
Right click on the desktop. Select File File Management Program on the right-key menu. Enter the etc directory. Open system files. Add UNIX core parameters to files ending with Oracle9i (There should be no blanks at the starting and ending of the file). Then, save the file.
set semsys:seminfo_semmni=100
set semsys:seminfo_semmns=1024
set semsys:seminfo_semmsl=256
set shmsys:shminfo_shmmax=4294967295
Purpose
Steps
Result
Purpose
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 205
set shmsys:shminfo_shmmin=1
set shmsys:shminfo_shmmni=100
set shmsys:shminfo_shmseg=10
2. Create user group and oracle user.
At terminal, use # admintool command to open system administrator tool.
i. Add three user groups such as install, dba and apchadm in system administrator tool.
Select View User Group from system administrator tool. Select Edit Add menu. Add User Group window appears. Input install, dba and apchadm in Group Name column. Select default values for other columns. Click OK.
ii. Add a user oracle (for Oracle database).
Select View User in system administrator tool. Select Edit Add menu. Add User window appears. Configure parameters as given below. Select default values for unlisted parameters. Click OK.
User name: oracle
Primary group: install
Secondary group: dba
Log in Shell: Bourne
Password: Normal password (It is required to input oracle password twice. It is recommended to use oracle.)
Create the main directory: Check the item.
Main directory path: /export/home/oracle (It is supposed that /expert/home is user division.)
iii. Add user apache (for Oracle HTTP Server).
Select View User in system administrator tool. Select Edit Add menu. Add User window appears. Configure parameters as given below. Select default values for unlisted parameters. Click OK.
User name: apache
Primary group: install
Secondary group: apchadm
Log in Shell: Bourne
Password: Normal password (It is required to input oracle password twice. It is recommended to use apache.)
Create the main directory: Check the item.
Main directory path: /export/home/apache (It is supposed that /expert/home is user division.)
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
206 Confidential and Proprietary Information of ZTE CORPORATION
NOTE: If it fails to use above-mentioned admintool normally, use commands below to add three user groups of install, dba apchadm and two users of oracle and apache.
#groupadd install
#groupadd dba
#groupadd apchadm
# useradd –d /export/home/oracle –g install –G dba –m oracle
#passwd oracle (It is required to input oracle password twice.)
# useradd –d /export/home/apache –g install –G apchadm –m apache
#passwd apache (It is required to input apache password twice.)
3. Copy oracle database files from netnumencluster1 to netnumencluster2.
root@ netnumencluster2# rcp –p netnumencluster1:/export/home/oracle.tar /export/home
root@ netnumencluster2# rcp –p netnumencluster1:/export/home/apache.tar /export/home
root@ netnumencluster2# rcp –rp netnumencluster1: /var/opt/oracle /var/opt
Note: Modify directory right:
root@ netnumencluster2# chmod –fR 777 /var/opt/oracle
4. Decompress oracle database file.
i. Decompress oracle database files of oracle.tar and apache.tar to the local.
root@ netnumencluster2# cd /export/home
ii. Decompress oracle.tar
root@ netnumencluster2# tar –xvf oracle.tar
iii. Decompress apache.tar.
root@ netnumencluster2# tar –xvf apache.tar
5. Modify machine name-related files.
i. Modify $ORACLE_HOME/network/admin/ listener.ora file: Modify host= netnumencluster2
ii. Modify $ORACLE_HOME/network/admin/ tnsnames.ora file: Modify host= netnumencluster2
NOTE: Remember to save operations.
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 207
6. Confirm whether it is successful to copy Oracle database.
Enable/disable operations manually to check whether it is successful to create oracle database on netnumencluster2. Follow steps below:
i. Mount oracle database files on disk array.
#mount /dev/dsk/c3t0d0s2 /export/home/oracle/oradata
ii. Enable oracle database.
If it is successful to install oracle database on netnumencluster2, Oracle database can be started normally.
END OF STEPS
Oracle database is successfully configured on netnumencluster2.
Back up oracle data files on disk array.
Backup files are used to resume Oracle database in faulty situation.
root@ netnumencluster2# cd /export/home/oracle
root@ netnumencluster2# tar –cvf oradata.tar /export/home/oracle/oradata
Modifying Oracle Database Service IP as Floating IP
To modify oracle database service IP to be floating IP.
Ensure both systems are installed with oracle database.
The float IP is 10.61.94.253.
To modify service IP, perform the following steps:
1. Modify $ORACLE_HOME/network/admin/ listener.ora file: Modify host=10.61.94. 253
2. Modify $ORACLE_HOME/network/admin/ tnsnames.ora file: Modify host=10.61.94. 253
NOTE: Perform operations on both systems.
Note: The database does not start if the floating IP 10.61.94.253 is not bound to the current computer. Use the ifconfig –a command to view computer IP address.
END OF STEPS
The oracle database service IP is modified to be floating IP successfully.
Result
Follow-up Step
Purpose
Preliminary Setup
Steps
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
208 Confidential and Proprietary Information of ZTE CORPORATION
Installing VCS4.0
To install dual hot backup system software VCS4.0
Installing VCS Software
To install VCS software.
NOTE: Install VCS software on either of both hosts, such as netnumencluster1. The installation program will install VCS software to the other host automatically.
Insert VCS installation CD storage_solutions_4.0 to netnumencluster1.
To install VCS software, execute the following commands:
1. root@ netnumencluster1# pwd
/cdrom/storage_solutions_4.0_cd1
2. root@ netnumencluster1# ./installer
VERITAS Storage Solutions 4.0
Copyright (c) 2004 VERITAS Software Corporation. All rights reserved.
VERITAS, the VERITAS Logo and all other VERITAS product names and slogans
are trademarks or registered trademarks of VERITAS Software Corporation.
VERITAS and the VERITAS Logo Reg. U.S. Pat. & Tm. Off. Other product names
and/or slogans mentioned herein may be trademarks or registered trademarks
of their respective companies.
VERITAS Storage Solutions 4.0
VERITAS Licensing utilities are not installed on this system
Selection Menu:
Purpose
Purpose
Preliminary Setup
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 209
I) Install/Upgrade a Product C) Configure an Installed Product
L) License a Product P) Perform a Preinstallation Check
U) Uninstall a Product D) View a Product Description
Q) Quit ?) Help
3. Enter a Selection: [I,C,L,P,U,D,Q,?] i
Install/Upgrade a Product
VERITAS Storage Solutions 4.0
1) VERITAS File System (FlashSnap Option)
2) VERITAS Volume Manager (FlashSnap Option, VVR Option)
3) VERITAS Volume Replicator
4) VERITAS Cluster Server
5) VERITAS Cluster Server Traffic Director
6) VERITAS Storage Foundation (QuickStart, Standard, Standard HA,
Enterprise, Enterprise HA, and VVR Option)
7) VERITAS Storage Foundation for Oracle (Standard, Enterprise,
Enterprise HA, VVR Option)
8) VERITAS Storage Foundation for DB2 (Standard, Enterprise, Enterprise
HA, VVR Option)
9) VERITAS Storage Foundation for Sybase (HA, FlashSnap Option, VVR
Option)
10) VERITAS SANPoint Control QuickStart
11) VERITAS Enterprise Administrator GUI
B) Back to previous menu
4. Select a product to install: [1-11,b,q] 4
VERITAS Cluster Server
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
210 Confidential and Proprietary Information of ZTE CORPORATION
Copyright (c) 2004 VERITAS Software Corporation. All rights reserved.
VERITAS, the VERITAS Logo and all other VERITAS product names and slogans
are trademarks or registered trademarks of VERITAS Software Corporation.
VERITAS and the VERITAS Logo Reg. U.S. Pat. & Tm. Off. Other product names
and/or slogans mentioned herein may be trademarks or registered trademarks
of their respective companies.
5. Enter the system names separated by spaces on which to install VCS: netnumencluster1 netnumencluster2
Checking system communication:
Checking OS version on netnumencluster1............................. SunOS 5.9
Checking VRTSvcs package ................................ not installed
Verifying communication with netnumencluster2................... ping successful
Attempting rsh with netnumencluster2............................. rsh successful
Attempting rcp with netnumencluster2............................. rcp successful
Checking OS version on netnumencluster2............................... SunOS 5.8
Checking VRTSvcs package ................................ not installed
Creating log directory on netnumencluster2................................. Done
Logs for installer are being created in /var/tmp/installer1115142948.
Using /usr/bin/rsh and /usr/bin/rcp to communicate with remote systems.
Initial system check completed successfully.
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 211
6. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
VERITAS Infrastructure package installation:
Installing VERITAS Infrastructure packages on netnumencluster1:
Checking VRTScpi package ................................ not installed
Checking VRTSvlic package ............................... not installed
Checking file system space ................ required space is available
Installing VRTScpi 4.0.5 on netnumencluster1............................. Done
Installing VRTSvlic 3.02.005d on netnumencluster1........................ Done
Installing VERITAS Infrastructure packages on netnumencluster2:
Checking VRTScpi package ................................ not installed
Checking VRTSvlic package ............................... not installed
Checking file system space ................ required space is available
Copying VRTScpi package to netnumencluster2................................ Done
Installing VRTScpi 4.0.5 on netnumencluster2............................... Done
Copying VRTSvlic.tar.gz to netnumencluster2................................ Done
Installing VRTSvlic 3.02.005d on netnumencluster2.......................... Done
VERITAS Infrastructure packages installed successfully.
7. Press [Return] to continue:
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
212 Confidential and Proprietary Information of ZTE CORPORATION
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
Each system requires a VCS product license before installation. License
keys for additional product features should also be added at this time.
Some license keys are node locked and are unique per system. Other license
keys, such as demo keys and site license keys, are registered on all systems
and must be entered on the first system.
VCS Licensing Verification:
Checking VCS license key on netnumencluster1..................... not licensed
Enter a VCS license key for netnumencluster1: [?] PZP9-WSXK-JTK8-TSBW-8PRC
Registering VERITAS Cluster Server DEMO key on netnumencluster1
8. Do you want to enter another license key for netnumencluster1? [y,n,q,?] (n)
Registering PZP9-WSXK-JTK8-TSBW-8PRC on netnumencluster2
Checking VCS license key on netnumencluster2................ Cluster Server Demo
9. Do you want to enter another license key for netnumencluster2? [y,n,q,?] (n)
VCS licensing completed successfully.
10. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 213
installer can install the following optional VCS packages:
VRTSobgui VERITAS Enterprise Administrator
VRTSvxfen VERITAS I/O Fencing
VRTSvcsmn VERITAS Cluster Server Man Pages
VRTSvcsdc VERITAS Cluster Server Documentation
VRTScssim VERITAS Cluster Server Simulator
VRTScscm VERITAS Cluster Server Cluster Manager
1) Install all of the optional packages
2) Install none of the optional packages
3) View package descriptions and select optional packages
11. Select the optional packages to be installed on all systems? [1-3,q,?] (1)
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
installer will install the following VCS packages:
VRTSperl VERITAS Perl 5.8.0 Redistribution
VRTSob VERITAS Enterprise Administrator Service
VRTSmuob VERITAS Enterprise Administrator Service Localized Package
VRTSobgui VERITAS Enterprise Administrator
VRTSllt VERITAS Low Latency Transport
VRTSgab VERITAS Group Membership and Atomic Broadcast
VRTSvxfen VERITAS I/O Fencing
VRTSvcs VERITAS Cluster Server
VRTSvcsmg VERITAS Cluster Server Message Catalogs
VRTSvcsag VERITAS Cluster Server Bundled Agents
VRTSvcsmn VERITAS Cluster Server Man Pages
VRTScspro VERITAS Cluster Server VEA Provider
VRTSvcsdc VERITAS Cluster Server Documentation
VRTSjre VERITAS Java Runtime Environment Redistribution
VRTScutil VERITAS Cluster Utilities
VRTScssim VERITAS Cluster Server Simulator
VRTScscw VERITAS Cluster Server Configuration Wizards
VRTSweb VERITAS Java Web Server
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
214 Confidential and Proprietary Information of ZTE CORPORATION
VRTSvcsw VERITAS Cluster Manager (Web Console)
12. Press [Return] to continue:
...continued:
VRTScscm VERITAS Cluster Server Cluster Manager
13. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
Checking system installation requirements:
Checking VCS installation requirements on netnumencluster1:
Checking VRTSperl package ............................... not installed
Checking VRTSob package ................................. not installed
Checking VRTSmuob package ............................... not installed
Checking VRTSobgui package .............................. not installed
Checking VRTSllt package ................................ not installed
Checking VRTSgab package ................................ not installed
Checking VRTSvxfen package .............................. not installed
Checking VRTSvcs package ................................ not installed
Checking VRTSvcsmg package .............................. not installed
Checking VRTSvcsag package .............................. not installed
Checking VRTSvcsmn package .............................. not installed
Checking VRTScspro package .............................. not installed
Checking VRTSvcsdc package .............................. not installed
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 215
Checking VRTSjre package ................................ not installed
Checking VRTScutil package .............................. not installed
Checking VRTScssim package .............................. not installed
Checking VRTScscw package ............................... not installed
Checking VRTSweb package ................................ not installed
Checking VRTSvcsw package ............................... not installed
Checking VRTScscm package ............................... not installed
Checking VERITAS patch 115209 ........................... not installed
Checking VERITAS patch 115212 ........................... not installed
Checking VERITAS patch 115210 ........................... not installed
Checking for any Solaris patch issues ............................ None
Checking file system space ................ required space is available
Checking VRTSweb process .................................. not running
Checking had process ...................................... not running
Checking hashadow process ................................. not running
Checking CmdServer process ................................ not running
Checking notifier process ................................. not running
Checking vxsvc process .................................... not running
Checking vxfen driver ..................................... not running
Checking gab driver ....................................... not running
Checking llt driver ....................................... not running
Checking VCS installation requirements on netnumencluster2:
Checking VRTSperl package ............................... not installed
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
216 Confidential and Proprietary Information of ZTE CORPORATION
Checking VRTSob package ................................. not installed
Checking VRTSmuob package ............................... not installed
Checking VRTSobgui package .............................. not installed
Checking VRTSllt package ................................ not installed
Checking VRTSgab package ................................ not installed
Checking VRTSvxfen package .............................. not installed
Checking VRTSvcs package ................................ not installed
Checking VRTSvcsmg package .............................. not installed
Checking VRTSvcsag package .............................. not installed
Checking VRTSvcsmn package .............................. not installed
Checking VRTScspro package .............................. not installed
Checking VRTSvcsdc package .............................. not installed
Checking VRTSjre package ................................ not installed
Checking VRTScutil package .............................. not installed
Checking VRTScssim package .............................. not installed
Checking VRTScscw package ............................... not installed
Checking VRTSweb package ................................ not installed
Checking VRTSvcsw package ............................... not installed
Checking VRTScscm package ............................... not installed
Checking VERITAS patch 115209 ........................... not installed
Checking VERITAS patch 115212 ........................... not installed
Checking VERITAS patch 115210 ........................... not installed
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 217
Checking for any Solaris patch issues ............................ None
Checking file system space ................ required space is available
Checking VRTSweb process .................................. not running
Checking had process ...................................... not running
Checking hashadow process ................................. not running
Checking CmdServer process ................................ not running
Checking notifier process ................................. not running
Checking vxsvc process .................................... not running
Checking vxfen driver ..................................... not running
Checking gab driver ....................................... not running
Checking llt driver ....................................... not running
Installation requirement checks completed successfully.
14. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
It is possible to install VCS packages without performing configuration.
VCS cannot be started without proper configuration.
It is optional to configure VCS now. If you choose to configure VCS later,
you can either do so manually or run the installvcs -configure command.
15. Are you ready to configure VCS? [y,n,q] (y)
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
218 Confidential and Proprietary Information of ZTE CORPORATION
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
installer will now ask sets of VCS configuration-related questions.
When a [b] is presented after a question, 'b' may be entered to go back to
the first question of the configuration set.
When a [?] is presented after a question, '?' may be entered for help or
additional information about the question.
Following each set of questions, the information you have entered will be
presented for confirmation. To repeat the set of questions and correct any
previous errors, enter 'n' at the confirmation prompt.
No configuration changes are made to the systems until all configuration
questions are completed and VCS is installed successfully.
16. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
To configure VCS the following is required:
A unique Cluster name
A unique Cluster ID number between 0-255
Two or more NIC cards per system used for heartbeat links
One or more heartbeat links are configured as private links
One heartbeat link may be configured as a low priority link
All systems are being configured to create one cluster
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 219
17. Enter the unique cluster name: [?] ztevcs
18. Enter the unique Cluster ID number between 0-255: [b,?] 100
Discovering NICs on netnumencluster1..................... discovered eri0 hme0 hme1
19. Enter the NIC for the first private heartbeat link on netnumencluster1: [b,?] hme0
hme0 is currently active as a public NIC on netnumencluster1
20. Are you sure you want to use hme0 for the first private heartbeat link? [y,n,q,b,?] (n) y
21. Would you like to configure a second private heartbeat link? [y,n,q,b,?] (y) y
22. Enter the NIC for the second private heartbeat link on hlrdbsrv1: [b,?] hme1
23. Would you like to configure a third private heartbeat link? [y,n,q,b,?] (y) n
24. Do you want to configure an additional low priority heartbeat link? [y,n,q,b,?] (n) y
25. Enter the NIC for the low priority heartbeat link on netnumencluster1: [b,?] (eri0) eri0
26. Are you using the same NICs for private heartbeat links on all systems? [y,n,q,b,?] (y) y
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
Cluster information verification:
Cluster Name: ztevcs
Cluster ID Number: 100
Private Heartbeat NICs for netnumencluster1: link1=hme0
Second Private Heartbeat NICs for netnumencluster1: link1=hme1
Low Priority Heartbeat NIC for netnumencluster1: link-lowpri=eri0
Private Heartbeat NICs for netnumencluster2: link1=hme0
Second Private Heartbeat NICs for netnumencluster2: link1=hme1
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
220 Confidential and Proprietary Information of ZTE CORPORATION
Low Priority Heartbeat NIC for netnumencluster2: link-lowpri=eri0
Is this information correct? [y,n,q] (y) y
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
The following information is required to configure Cluster Manager:
A public NIC used by each system in the cluster
A Virtual IP address and netmask for Cluster Manager
27. Do you want to configure Cluster Manager (Web Console) [y,n,q] (y) n
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
The following information is required to configure SMTP notification:
The domain-based hostname of the SMTP server
The email address of each SMTP recipient
A minimum severity level of messages to send to each recipient
28. Do you want to configure SMTP notification? [y,n,q] (y) n
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
The following information is required to configure SNMP notification:
System names of SNMP consoles to receive VCS trap messages
SNMP trap daemon port numbers for each console
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 221
A minimum severity level of messages to send to each console
29. Do you want to configure SNMP notification? [y,n,q] (y) n
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
VCS packages can be installed on systems consecutively or simultaneously.
Installing packages on systems consecutively takes more time but allows for
better error handling.
30. Would you like to install Cluster Server packages on all systems simultaneously? [y,n,q,?] (y) y
Installing Cluster Server 4.0 on all systems simultaneously:
Copying VRTSperl.tar.gz to netnumencluster2.................. Done 1 of 69 steps
Installing VRTSperl 4.0.2 on netnumencluster2................ Done 2 of 69 steps
Installing VRTSperl 4.0.2 on netnumencluster1 .............. Done 3 of 69 steps
Copying VRTSob.tar.gz to netnumencluster2.................... Done 4 of 69 steps
Installing VRTSob 3.2.514.0 on netnumencluster2.............. Done 5 of 69 steps
Copying VRTSmuob.tar.gz to netnumencluster2.................. Done 6 of 69 steps
Installing VRTSmuob 3.2.514.0 on netnumencluster2............ Done 7 of 69 steps
Installing VRTSob 3.2.514.0 on netnumencluster1 ............ Done 8 of 69 steps
Copying VRTSobgui.tar.gz to netnumencluster2................. Done 9 of 69 steps
Installing VRTSmuob 3.2.514.0 on netnumencluster1 ......... Done 10 of 69 steps
Installing VRTSobgui 3.2.514.0 on netnumencluster2.......... Done 11 of 69 steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
222 Confidential and Proprietary Information of ZTE CORPORATION
Copying VRTSllt.tar.gz to netnumencluster2.................. Done 12 of 69 steps
Installing VRTSllt 4.0 on netnumencluster2.................. Done 13 of 69 steps
Installing VRTSobgui 3.2.514.0 on netnumencluster1 ........ Done 14 of 69 steps
Copying VRTSgab.tar.gz to netnumencluster2.................. Done 15 of 69 steps
Installing VRTSllt 4.0 on netnumencluster1 ................ Done 16 of 69 steps
Installing VRTSgab 4.0 on netnumencluster2.................. Done 17 of 69 steps
Copying VRTSvxfen.tar.gz to netnumencluster2................ Done 18 of 69 steps
Installing VRTSgab 4.0 on netnumencluster1 ................ Done 19 of 69 steps
Installing VRTSvxfen 4.0 on netnumencluster2................ Done 20 of 69 steps
Installing VRTSvxfen 4.0 on netnumencluster1 .............. Done 21 of 69 steps
Copying VRTSvcs.tar.gz to netnumencluster2.................. Done 22 of 69 steps
Installing VRTSvcs 4.0 on netnumencluster2.................. Done 23 of 69 steps
Copying VRTSvcsmg.tar.gz to netnumencluster2................ Done 24 of 69 steps
Installing VRTSvcsmg 4.0 on netnumencluster2................ Done 25 of 69 steps
Copying VRTSvcsag.tar.gz to netnumencluster2................ Done 26 of 69 steps
Installing VRTSvcs 4.0 on netnumencluster1 ................ Done 27 of 69 steps
Installing VRTSvcsmg 4.0 on netnumencluster1 .............. Done 28 of 69 steps
Installing VRTSvcsag 4.0 on netnumencluster2 ................ Done 29 of 69 steps
Installing VRTSvcsag 4.0 on netnumencluster1 .............. Done 30 of 69 steps
Copying VRTSvcsmn.tar.gz to netnumencluster2 ................ Done 31 of 69 steps
Installing VRTSvcsmn 4.0 on netnumencluster1 .............. Done 32 of 69 steps
Installing VRTSvcsmn 4.0 on netnumencluster2 ................ Done 33 of 69 steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 223
Installing VRTScspro 4.0 on netnumencluster1 .............. Done 34 of 69 steps
Copying VRTScspro.tar.gz to netnumencluster2 ................ Done 35 of 69 steps
Installing VRTSvcsdc 4.0 on netnumencluster1 .............. Done 36 of 69 steps
Installing VRTScspro 4.0 on netnumencluster2 ................ Done 37 of 69 steps
Copying VRTSvcsdc.tar.gz to netnumencluster2 ................ Done 38 of 69 steps
Installing VRTSvcsdc 4.0 on netnumencluster2 ................ Done 39 of 69 steps
Copying VRTSjre.tar.gz to netnumencluster2 .................. Done 40 of 69 steps
Installing VRTSjre 1.4 on netnumencluster1 ................ Done 41 of 69 steps
Installing VRTSjre 1.4 on netnumencluster2 .................. Done 42 of 69 steps
Installing VRTScutil 4.0 on netnumencluster1 .............. Done 43 of 69 steps
Copying VRTScutil.tar.gz to netnumencluster2 ................ Done 44 of 69 steps
Installing VRTScssim 4.0 on netnumencluster1 .............. Done 45 of 69 steps
Installing VRTScscw 4.0 on netnumencluster1 ............... Done 46 of 69 steps
Installing VRTScutil 4.0 on netnumencluster2 ................ Done 47 of 69 steps
Copying VRTScssim.tar.gz to netnumencluster2 ................ Done 48 of 69 steps
Installing VRTSweb 4.0 on netnumencluster1 ................ Done 49 of 69 steps
Installing VRTScssim 4.0 on netnumencluster2 ................ Done 50 of 69 steps
Installing VRTSvcsw 4.0 on netnumencluster1 ............... Done 51 of 69 steps
Copying VRTScscw.tar.gz to netnumencluster2 ................. Done 52 of 69 steps
Installing VRTScscw 4.0 on netnumencluster2 ................. Done 53 of 69 steps
Installing VRTScscm 4.0 on netnumencluster1 ............... Done 54 of 69 steps
Copying VRTSweb.tar.gz to netnumencluster2 .................. Done 55 of 69 steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
224 Confidential and Proprietary Information of ZTE CORPORATION
Installing VRTSweb 4.0 on netnumencluster2 .................. Done 56 of 69 steps
Copying VRTSvcsw.tar.gz to netnumencluster2 ................. Done 57 of 69 steps
Installing VRTSvcsw 4.0 on netnumencluster2 ................. Done 58 of 69 steps
Copying VRTScscm.tar.gz to netnumencluster2 ................. Done 59 of 69 steps
Adding patch 115209-05 on netnumencluster1 ................ Done 60 of 69 steps
Installing VRTScscm 4.0 on netnumencluster2 ................. Done 61 of 69 steps
Copying 115209-05.tar.gz to netnumencluster2 ................ Done 62 of 69 steps
Adding patch 115212-05 on netnumencluster1 ................ Done 63 of 69 steps
Adding patch 115210-05 on netnumencluster1 ................ Done 64 of 69 steps
Adding patch 115209-05 on netnumencluster2 .................. Done 65 of 69 steps
Copying 115212-05.tar.gz to netnumencluster2 ................ Done 66 of 69 steps
Adding patch 115212-05 on netnumencluster2 .................. Done 67 of 69 steps
Copying 115210-05.tar.gz to netnumencluster2 ................ Done 68 of 69 steps
Adding patch 115210-05 on netnumencluster2 .................. Done 69 of 69 steps
Cluster Server installation completed successfully.
31. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
Configuring Cluster Server:
Creating Cluster Server configuration files ...................... Done
Copying configuration files to netnumencluster1 .......................... Done
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 225
Copying configuration files to netnumencluster2 ............................ Done
Cluster Server configured successfully.
32. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
33. Do you want to start Cluster Server processes now? [y,n,q] (y)
Starting Cluster Server:
Starting LLT on netnumencluster1 ...................................... Started
Starting LLT on netnumencluster2 ........................................ Started
Starting GAB on netnumencluster1 ...................................... Started
Starting GAB on netnumencluster2 ........................................ Started
Starting Cluster Server on netnumencluster1 ........................... Started
Starting Cluster Server on netnumencluster2 ............................. Started
Confirming Cluster Server startup ................... 2 systems RUNNING
Cluster Server was started successfully.
34. Press [Return] to continue:
VERITAS CLUSTER SERVER 4.0 INSTALLATION PROGRAM
Installation of Cluster Server 4.0 has completed successfully.
The installation summary is saved at:
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
226 Confidential and Proprietary Information of ZTE CORPORATION
/opt/VRTS/install/logs/installer1115142948.summary
The installer log is saved at:
/opt/VRTS/install/logs/installer1115142948.log
The installation response file is saved at:
/opt/VRTS/install/logs/installer1115142948.response
END OF STEPS
VCS is successfully installed.
Note: Installation procedures are various with different VCS versions.
Installing VCS Patch
Install the latest VCS patch if there is one.
Installing VCS Oracle Agent Software
To install VCS oracle agent software.
To install VCS oracle agent software, perform the following step:
root@ netnumencluster1 # pwd
/cdrom/cdrom0/storage_solutions_4.0_cd1/cluster_server_agents/oracle_agent/pkgs
root@ netnumencluster1 # pkgadd –d.
NOTE: There is a ‘.’ mark at the end of –d. Do not forget it.
Select Complete Install.
NOTE: Perform operations on both systems.
END OF STEPS
VCS oracle agent software is installed successfully.
Result
Purpose
Steps
Result
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 227
Configuring VCS System Remember to save all settings before exiting VCS management interface. Otherwise, all settings may be lost. If the system is restarted without saving settings, it may fail to login to VCS.
Click the third icon in the tool bar on the VCS Cluster Administrator interface. If the setting is not saved, the icon is bright. If the setting is saved, the icon is dimmed.
Starting VCS Cluster Manager
To start VCS cluster manager.
To start VCS cluster manager, perform the following steps:
1. Logon VCS Cluster Manager interface on netnumencluster1 as shown in Figure 252.
root@ netnumencluster1 # hagui &
F I G U R E 252 − OP E N I N G VCS C L U S T E R MAN AG E R I N T E R F AC E
2. Select File New Cluster. Input netnumencluster1 in Host Name text box. Select default values for other parameters. Click OK as shown in Figure 253.
F I G U R E 253 − C R E AT I N G A N E W C L U S T E R
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
228 Confidential and Proprietary Information of ZTE CORPORATION
3. After creating a new VCS, the interface is shown in Figure 254. Click the new cluster to pop up the login interface.
F I G U R E 254 − C L U S T E R MO N I T O R I N T E R F AC E AF T E R VCS I S C R E AT E D
4. Input user name and password. By default, the user name is admin. The password is password. Click OK. VCS Cluster Administrator window appears as shown in Figure 255. Change the user name and password after debugging.
F I G U R E 255 − VCS CL U S T E R AD M I N I S T R AT O R I N T E R F AC E
END OF STEPS
VCS cluster manager is started up successfully. Result
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 229
Adding Oracle Resource Group
To add oracle resource group.
Importing Oracle Type
To import oracle type.
1. Select File Import Type in the VCS Cluster Administrator window as shown in Figure 255. Import Type window appears as shown in Figure 256.
F I G U R E 256 − IM P O R T I N G OR AC L E TY P E
2. Select /etc/VRTSvcs/conf/OracleTypes.cf.
END OF STEPS
Oracle type is imported successfully.
Creating Oracle Resource Group
To create oracle resource group.
1. Select Edit Add Service Group in VCS Cluster Administrator window as shown in Figure 255. Add Service Group window appears as shown in Figure 257.
Purpose
Purpose
Steps
Result
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
230 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 257 − AD D I N G OR A C L E R E S O U R C E GR O U P
2. Input oracle in the Oracle Service Group text box. Select systems for service group in sequence: netnumencluster2 and netnumencluster1. Select Startup. Click Templates… button. Select Templates as shown on the left pane. Select OracleGroup. Click OK.
Figure 258 shows relationship of resources and resource groups containing in oracle resource group.
F I G U R E 258 − R E L AT I O N S H I P B E T W E E N OR AC L E R E S O U R C E GR O U P AN D R E S O U R C E S
END OF STEPS
Oracle resource group is created successfully. Result
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 231
Configuring Resources in Oracle Resource Group
To configure resources in oracle resource group.
To configure resources, perform the following steps:
1. Adding/modifying/deleting resource
NOTE: Take IP resource as an example.
Adding resource
i. Select Oracle resource group in the Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Right click on it. Select Add Resource menu. Add Resource window appears as shown in Figure 259.
F I G U R E 259 − AD D I N G R E S O U R C E
ii. Input Ora_IP in the Resource name text box. Select IP for Resource Type. Adding different resources is to select various resource types. Check Enabled check box. Click OK. IP resource is added.
iii. Click the third icon in the tool bar on the Relationship between Oracle Resource Group and Resources window as shown in Figure 258 to save settings.
Modifying resource property
i. Select one resource, for instance, Ora_IP, in the Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Select
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
232 Confidential and Proprietary Information of ZTE CORPORATION
Properties tab, which displays properties of Ora_IP resource. Select one property. Modify it.
ii. Click the third icon in the tool bar on the Relationship between Oracle Resource Group and Resources window as shown in Figure 258 to save settings.
Delete resource
Select one resource, for instance, Ora_IP, in the Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Right click on it. Select delete to delete this resource.
2. Verify AutoStartList resource
i. Select one resource group, for instance, oracle, in the Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Select Properties tab. View AuotStartList property as shown in Figure 260.
F I G U R E 260 − AU T O S T AR T L I S T P R O P E R T Y
ii. If the sequence is wrong, select an oracle resource group in Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Select Properties tab.
iii. Click Edit button for AutoStartList property. Edit Attribute window appears as shown in Figure 261.
iv. Click to add. Click to delete. Change the sequence as shown in Figure 261.
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 233
F I G U R E 261 − E D I T AT T R I B U T E
NOTE: AutoStartList property configuration decides on which system oracle resource group (namely, oracle database) runs in priority when both systems are restarted. In this instance, it runs on NETNUMENCLUSTER2 in priority. The configuration is contrary to AutoStartList property setting of NM resource. NM server runs on netnumencluster1 in priority. Oracle database and NM server can run on different systems by default, ensuring loadings of both systems are equal.
3. IP resource Ora_IP
Use Ora_IP to specify IP address, subnet mask and NIC type of Oracle database.
NOTE: The IP address here is the floating IP address of oracle database. For cluster system, on which system oracle runs, the floating IP is switched to this system, ensuring oracle database provides transparent database service externally.
Modify IP resources based on properties below:
Device = eri0
Address = "10.61.94.253"
SubNetMask = "255.255.252.0"
4. DiskReservation resource oracle_diskRes
i. DiskReservation resources ensure that only one system can access disk array. If heartbeat cable is disconnected, both systems may access disk array. Data or file system may be damaged.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
234 Confidential and Proprietary Information of ZTE CORPORATION
ii. Presently, hard disks for disk array are SCSI, SCSI or fiber disk. DiskReservation resources support all of them.
iii. Set Disks property of DiskReservation to be logical device name of Oracle database disk array resource. Select Global. Input one logical device name.
DiskReservation oracle_diskRes (
Disks = { c3t0d0s2}
FailFast = 1
)
iv. Setting FailFast as 1 (true) indicates that when VCS detects access collision occurs on partition under the management of DiskReservation resource, resource fail will be faster. By default, the value for FailFast is 0 (false).
v. For VCS4.0forSolaris, a problem exists after DiskReservation is added to resource group. That is, it can fail to start resource group automatically when both systems are rebooted at the same time. Set resource group online manually to solve the problem. Use init 6 command to reboot the system to avoid the problem.
Note: While taking dual system test, if the system uses DiskReservation resource, it is required to use init 6 command to reboot the system, instead of reboot command.
5. MOUNT resource Ora_Mnt_Data
Use MOUNT resource to specify file resource of oracle database, mount point on the system and relevant system directory of mount point.
Mount point is /export/home/oracle/oradata.
Mount Ora_Mnt_Data (
MountPoint = " /export/home/oracle/oradata"
BlockDevice = "/dev/dsk/ c3t0d0s2"
FSType = ufs
FsckOpt = "-y"
)
6. NIC resource Ora_NIC
Use NIC resource Ora_NIC to specify network interface offering oracle service externally. Network interface information for both systems is the same. In this instance, port is eri0. Port type is ether.
NIC Ora_NIC (
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 235
Device = eri0
NetworkType = ether
)
Note: Configure eri0 according to on-site network interface card.
7. Oracle database resource Ora_Oracle
Use Oracle database resource Ora_Oracle to specify oracle database information. Contents below show configurations.
Oracle Ora_oracle (
Sid = uep
Owner = oracle
Home = "/export/home/oracle/product/9.2.0"
Pfile = "/export/home/oracle/product/9.2.0/dbs/inituep.ora"
MonScript = "./bin/Oracle/SqlTest.pl" )
8. Oracle database monitoring resource Ora_Netlsnr
Use oracle database monitoring resource Ora_Netlsnr to specify oracle database monitoring resource information. Contents below show configurations.
Netlsnr Ora_Netlsnr (
Owner = oracle
Home = "/export/home/oracle/product/9.2.0"
TnsAdmin = "/export/home/oracle/product/9.2.0/network/admin"
Listener = LISTENER
MonScript = "./bin/Netlsnr/LsnrTest.pl"
)
END OF STEPS
The resources in oracle resource group are configured successfully.
Create relationship of resources in Oracle resource group.
Relationship of resources in Oracle resource group indicates the sequence of starting resources while starting oracle resource group. Refer Relationship between Oracle Resource Group and Resources window as shown in Figure 258.
Result
Follow-up Action
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
236 Confidential and Proprietary Information of ZTE CORPORATION
Select an oracle resource group. Select Resource tab. Click
button to link resources.
Method of connecting resources is:
1. Click the button. Select Ora_IP resource. Move the mouse, pointing to Ora_NIC. The relationship shown in Figure 262 is created. Create other relationships in this way.
F I G U R E 262 − C R E AT I N G R E S O U R C E R E L A T I O N S H I P
2. Resource relationship indicates the sequence of starting/stopping resources in oracle resource group. It is the foundation of ensuring resources normal running.
The sequence of starting resources is: Start resources from the bottom up.
The sequence of stopping resources is: Stop resources from the top down.
Testing Oracle Resource Group
To test oracle resource group to verify whether oracle resource group is configured correctly.
Oracle resource group must be configured.
To test oracle resource group, perform the following steps:
1. Select Oracle Resource in Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Right click on it. Select online netnumencluster1. Oracle database is started on netnumencluster1 automatically.
2. Select oracle resource. Right click on it. Select switch to netnumencluster2. Oracle database is switched over to netnumencluster2.
END OF STEPS
Oracle resource group is tested successfully.
Purpose
Preliminary Setup
Steps
Result
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 237
Adding NM Resource Group
To add NM resource group.
Installing NM Program
To install NM program.
To install NM program, perform the following steps:
1. Create required directories for NM server.
Create the ‘netnumen’ directory as root user, which is the installation directory for NM server.
# cd /
# mkdir netnumen
Create the ‘/export/home/ backup’ directory as root user, which is a directory for saving NM backup files. .
#cd/export/home
# mkdir backup
NOTE: Perform the first operation on both systems.
2. Mount on disk array and install NM server program on disk array.
i. Install NetNumen N31 NM program on disk array, ensuring that NM server data is consistent.
ii. If oracle database is running, mount disk array on the system. If Oracle database is not running, mount disk array on any system. Here, it is supposed that oracle database is running on netnumencluster1, mount disk array on netnumencluster1.
iii. For instance, mount NM partition on disk array to netnumen directory on netnumencluster1.
root@ netnumencluster1 # mount /dev/dsk/ c3t0d1s2 /netnumen
Result: It is possible to view the ‘/netnumen’ directory on netnumencluster1.
3. Run NM installation program to install NM program.
Run install.sh to install NM server to the ‘/netnumen’ directory.
END OF STEPS
NM program is installed successfully.
Perform step 2 and 3 on one system.
Purpose
Purpose
Steps
Result
Follow-up Action
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
238 Confidential and Proprietary Information of ZTE CORPORATION
Configuring NetNumen N31 Program
To configure NetNumen N31 program.
NOTE: Perform operations below only on one system.
Ensure NM server runs normally.
To configure NetNumen N31 program, perform the following steps:
1. Ensure oracle database is running.
i. Ensure oracle database is started normally before configuring NM server. Generally, oracle database is started normally after oracle database resource is configured. If not, start oracle database on the system mounted with NM program. Open VCS management interface. Perform the following operation to start database:
ii. Select oracle resource group in Relationship between Oracle Resource Group and Resources window as shown in Figure 258. Right click on it. Select Online netnumencluster1. Start Oracle database on netnumencluster1.
2. Modify NM database configuration script install-db-conf.sh.
The script file is /netnumen/ums-svr/docs/dbscript/install-db/uep/unix/ install-db-conf.sh. Modify system password of oracle database.
##### database system user and password
SYSTEM_USER=system
SYSTEM_PWD=manager
NOTE: Modify the password as required.
3. Modify NM database script.
Create specified NM database space on disk array.
Since two systems need share NM data in the database, it is required to create NM database on share disk space. Modify the script files below. The specified NM database space resides at /export/home/oracle/oradata. For English operating system, modify the script under relevant dbscript-en.
//../ums-svr/docs/dbscript/dbscript-zh is script for English operating system.
i. Modify UEP table location.
\\..\\ums-svr\docs\dbscript\dbscript-zh\oracle\uep\common\jms-createdb-ora.sql
Original script:
Purpose
Preliminary Setup
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 239
s := 'create tablespace uep datafile "uep.dbf" size 500 M REUSE AUTOEXTEND ON NEXT 1M ONLINE PERMANENT'
Modified script:
s:= 'create tablespace uep datafile "/export/home/oracle/oradata/uep.dbf" size 500 M REUSE AUTOEXTEND ON NEXT 1M ONLINE PERMANENT'
ii. Modify UEP table location.
\\..\\ums-svr\docs\dbscript\dbscript-zh\oracle\uep\common\uep-createdb-ora.sql
Original script: datafile 'uep.dbf' size 500M REUSE
Modified script: datafile '/export/home/oracle/oradata/uep.dbf' size 500 M REUSE
iii. Modify UEP _PM table location.
\\..\\ums-svr\docs\dbscript\dbscript-zh\oracle\uep\pal\pm\uep-pal-pm-createdb-ora.sql
Original script: datafile 'UEP_PM.dbf' size 100M REUSE
Modified script: datafile '/export/home/oracle/oradata/uep.dbf' size 500M REUSE
iv. Modify UEP _ CAT_FM table location
\\..\\ums-svr\docs\dbscript\dbscript-zh\oracle\uep\pal\fm\uep-pal-fm-createdb-ora.sql
Original script: datafile 'UEP_CAF_FM.dbf' size 100M REUSE
Modified script: datafile '/export/home/oracle/oradata/UEP_CAF_FM.dbf' size 100M REUSE
NOTE: Save modifications.
4. Create NM database.
After modifying NM database script, run NM database script to create NM database. Perform operations on the system which is running Oracle database and mounted with NM program.
i. Switch to oracle user.
root@ netnumencluster1#su - oracle
ii. Enter NM database script installation directory.
root@ netnumencluster1$cd / netnumen/ums-svr/docs/dbscript/install-db/uep/unix
iii. Run database script.
root@ netnumencluster1# ./install.sh
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
240 Confidential and Proprietary Information of ZTE CORPORATION
Note: If oracle user is failed to access install.sh file or install.sh is not executable, perform following operations as root user:
#cd / netnumen/ums-svr/docs
Change all files in the / netnumen/ums-svr/docs/ dbscript directory to be executable and accessible files.
#chmod –R 777 dbscript
After modification, repeat steps 1, 2 and 3 to create NM database.
5. Verify whether NM database is created in the correct directory.
Perform following operations to verify whether NM database is created in the correct directory. The right path is /export/home/oracle/oradata.
i. Switch to oracle user.
root@ netnumencluster1#su - oracle
ii. Logon to the database.
root@ netnumencluster1$ sqlplus /nollog
SQL> sqlplus /as sysdba
iii. Query NM database table space location.
If the NM database table space location is /export/home/oracle/product/9.2.0/dbs or others, instead of /export/home/oracle/oradata, there is error to create NM database location. Enter the fault processing flow.
Note: If UEP_CAF_FM.dbf, UEP_PM.dbf, and UEP.dbf are in /export/home/oracle/product/9.2.0/dbs or other directories, instead of /export/home/oracle/oradata, there is error to create NM database location. Do not switch the database to another system. Otherwise, the database cannot start. Delete NM database table space immediately.
iv. Switch to oracle user.
root@ netnumencluster1#su - oracle
v. Log on to database.
root@ netnumencluster1$ sqlplus /nollog
SQL> sqlplus /as sysdba
vi. Delete NM database table space.
Delete uep table space.
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 241
SQL> DROP TABLESPACE uep INCLUDING CONTENTS CASCADE CONSTRAINTS
Delete UEP_PM table space.
SQL> DROP TABLESPACE UEP_PM INCLUDING CONTENTS CASCADE CONSTRAINTS,
Delete UEP_CAF_FM table space.
SQL> DROP TABLESPACE UEP_CAF_FM INCLUDING CONTENTS CASCADE CONSTRAINTS,
Commit above operations.
SQL>commit
vii. Verify that NM database table space is deleted.
SQL> select tablespace_name from dba_tablespaces where tablespace_name like ‘UEP%’;;
Run sql statement. If the NM database table space is successfully deleted, no UEP, UEP_PM, or UEP_CAF_FM exists.
viii. Repeat steps 3, 4 and 5 to create NM database. Create NM database to disk array again.
Check step 3, ensuring that specified NM database table space is created on disk array. Modify NM database script, ensuring that specified NM database table space is created on disk array. Recreate NM database space, ensuring that NM database table space is created in the specified directory.
6. Configure database IP in NM configuration center.
Run the /netnumen/tools/configcenter/bin/run.sh file to start NM configuration center. Select database service. Set IP address to be the floating IP of oracle database: 10.61.94.253. Test database connection. Figure 263 shows the normal connection.
F I G U R E 263 − N E T N U M E N NM C O N F I G U R AT I O N C E N T E R
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
242 Confidential and Proprietary Information of ZTE CORPORATION
Complete FTP Service configuration by referring to ‘UNIX NM Configuration Center’ section. Click Save to save the configurations.
Then, check whether the /netnumen/ums-svr/deploy/deploy properties file is modified. Refer to configurations below:
# Datasource configuration for ZXSS performance manager
zxss-osf-pm.zxss-osf-pm.ds.ip=10.61.94.253
zxss-osf-pm.zxss-osf-pm.ds.databasename=uep
7. Complete other NM server configurations.
Complete other NM server configurations. NM server is multiple IP environment. Perform multiple IP NM server configuration.
Modify the following parameters of the file ‘\ums-svr\netnumen\ip\dsl\dsl-base.par\conf\IPMS_param.xml’
<FTP_PARAMETERS
FTPIPAddress="localhost" />
Change FTPIPAddress="localhost to be the NM IP address with which NE can use ftp.
END OF STEPS
NetNumen N31 program is successfully configured.
NM Program Running Test
To test whether NM is running normally.
To test whether NM is running normally, perform the following steps:
1. Start /netnumen/ums-svr/bin/console.sh manually. Check Start upon startup of UMS Console check box on the right corner, as shown in Figure 264. When VCS starts, NM server starts automatically.
Result
Purpose
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 243
F I G U R E 264 − S T AR T I N G NM S E R V E R TE S T
2. Start NM server. Test whether NM server can be started normally and run.
3. Logon NM client. Check whether NM server works normally.
NOTE: If NM server can be started normally and run, close console. Modify the /netnumen/ums-svr/platform/psl/ext-service/console/conf/maincontroller.xml file. UNIX operating system does not display console interface when console is started via VCS.
maincontroller.xml
……
<! – Whether the console has interface or not. The parameter is set to be an integer. 1 – With interface, 0 – Without interface>
<client-type>0</client-type>
…….
END OF STEPS
NM program is running successfully.
Note: Save the modification after maincontroller.xml file is modified.
Creating NM Server Resource Group
To create NM server resource group.
NOTE: Perform operations below only on one system.
Result
Purpose
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
244 Confidential and Proprietary Information of ZTE CORPORATION
To create NM server resource group, perform the following steps:
1. Create NM resource group (nms-grp) in VCS.
i. Select Edit add service group in VCS Cluster Administrator window as shown in Figure 255. Add Service Group window appears as shown in Figure 265.
F I G U R E 265 − AD D I N G NM S E R V E R R E S O U R C E GR O U P N M S -G R P
ii. Input nms-grp in Service Group Name text box. Select systems for service group in the sequence of netnumencluster1 and netnumencluster2 (the sequence is the same as that for AutoStartList). Check Startup. Click OK. The resource group nms-grp is created.
Figure 266 shows relationship of resources and resources containing in NM resource group.
F I G U R E 266 − R E L AT I O N S H I P O F R E S O U R C E S I N NM R E S O U R C E GR O U P
2. Verify AutoStartList property in nms-grp.
Steps
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 245
The sequence of AutoStartList in nms-grp should be:
group nms-grp (
AutoStartList = {netnumencluster1, netnumencluster2}
)
NOTE: AutoStartList attribute setting decides on which system the nms-grp resource group runs in priority when both systems are restarted. In this instance, the nms-grp resource group runs on NETNUMENCLUSTER1 in priority. The setting is contrary to AutoStartList attribute setting of oracle resource group, ensuring that oracle database and NM server run on different systems by default.
3. IP resource nms_IP.
i. Use nms_IP to specify IP address, subnet mask and NIC type of NM server.
ii. IP address here is the floating IP address of NM server. For cluster system, on which system NM server runs, the floating IP is switched to this system, ensuring NM server providing transparent database service externally.
iii. Select Add Resource in Relationship of Resources in NM Resource Group window as shown in Figure 266. The window for adding resource pops up. Select IP for Resource Type. Input nms_IP in the Resource Name text box. Select Enable. Set other attributes as follows:
IP nms_IP (
Device = eri0
Address = "10.61.94.254"
SubNetMask = "255.255.252.0"
)
4. DiskReservation resource nms_diskRes and nms_backup_diskRes.
DiskReservation resources ensure that only one system can access disk array. If heartbeat cable is disconnected, both systems may access disk array. Data or file system may be damaged.
Set disk property of DiskReservation to be logical device name of NM server disk array resource. Select Global. Input one logical device name.
Select nms-grp in Relationship of Resources in NM Resource Group window as shown in Figure 266. Select Add Resource. The window for adding resource pops up. Select DiskReservation for Resource Type. Input nms_diskRes and nms_backup_diskRes in Resource Name text box. Select Enable. Set other attributes as follows:
i. DiskReservation resource nms_diskRes.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
246 Confidential and Proprietary Information of ZTE CORPORATION
Use nms_diskRes to manage disk array partition of NM server.
DiskReservation nms_diskRes (
Disks = { c3t0d1s2}
FailFast = 1
)
Setting FailFast as 1 (true) indicates that when VCS detects access collision occurs on partition under the management of DiskReservation resource, resource fail is faster. By default, the value for FailFast is 0 (false).
ii. DiskReservation resource nms_backup_diskRes.
Use nms_backup_diskRes to manage disk array partition of NM backup data.
DiskReservation nms_ backup _diskRes (
Disks = { c3t0d2s2}
FailFast = 1
)
For VCS4.0forSolaris, a problem exists after DiskReservation is added to resource group. That is, it may fail to start resource group automatically when both systems are rebooted at the same time. Set resource group online manually to solve the problem. Using init 6 command to reboot the system can avoid the problem.
Note: While taking dual system test, if the system uses DiskReservation resource, it is required to use the init 6 command to reboot the system, instead of reboot command.
5. MOUNT resources nms_Mnt_Data and nms_backup_Mnt_Data.
Use MOUNT resource to specify relationship between NM server and NM backup data’s directories and disk array file systems.
The directory for NM server is /netnumen. The file system of relevant disk array is /dev/dsk/c3t0d1s2.
The directory for NM backup data is /export/home/backup. The file system of relevant disk array is /dev/dsk/c3t0d2s2.
Select Add Resource in Relationship of Resources in NM Resource Group window as shown in Figure 266. The window for adding resource pops up. Select Mount for Resource Type. Input nms_Mnt_Data and nms_backup_Mnt_Data in the Resource Name text box. Select Enable. Set other attributes as follows:
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 247
i. Mount resource for NM server: nms_Mnt_Data
ii. Mount resource for NM backup file: nms_backup_Mnt_Data
6. NIC resource Proxy resource nms_NIC.
Both NM programme and Oracle database share the same network interface card. The network interface card resource is added in oracle resource group. It is required to create a proxy network interface card resource in nms-grp NM resource group, pointing to Ora_NIC. It indicates that NM resource group also uses Ora_NIC as its own network interface card resource.
Right click on nms-grp in Relationship of Resources in NM Resource Group window as shown in Figure 266. Select Add Resource. Select Proxy for resource type. The resource name is nms_NIC. Select Enable. Edit TargetResName to be Ora_NIC, the NIC resource name in oracle resource group.
Proxy nms_NIC (
TargetResName =Ora_NIC
)
7. Preparations for adding Application resource netnumen.
i. Configure required parameters. Ensure it is possible to start NM system manually.
ii. Follow steps introduced in this file. It is recommended to refer to the /netnumen/tools/cluster/readme.txt file.
iii. Copy the / netnumen/tools/cluster, jdk-solairs file in NM server version to the /export/home/cluster of netnumencluster1.
cp -r /netnumen/tools/cluster /export/home
cp -r /netnumen/ jdk-solaris /export/home/cluster
iv. Modify script according to the real path of NM server and script.
Here, the NM server path is /netnumen, the NM script path is /export/home/cluster, the script JAVA path is /export/home/cluster/ jdk-solaris.
Modify the /export/home/ cluster/ moni_sol.sh file.
Modify MONI_HOME location according to real directory
MONI_HOME="/export/home/cluster"
Modify JAVA location according to real directory
JAVA="/export/home/cluster/jdk-solaris/bin/java"
Modify the /export/home/ cluster/ offline_sol.sh file.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
248 Confidential and Proprietary Information of ZTE CORPORATION
Set PROCESSPATH below based on the started java process.
PROCESSPATH="/netnumen"
v. Ensure that both moni_sol.sh and offline_sol.sh have the execution rights of root user.
Select moni_sol.sh file. Right click on it. Select Modify Right. Check whether there is execution right. If there is no right, execute commands below to give rights to the script.
root@ netnumencluster1# cd /export/home
root@ netnumencluster1# chmod –R 777 cluster
vi. Copy the script directory of /export/home/cluster to the same directory of netnumencluster2.
Execute the command below on netnumencluster2. Copy the modified script directory.
root@ netnumencluster2# rcp –p netnumencluster1:/export/home/cluster /export/home
Authorize relevant files in script directory with execution right as root user.
root@ netnumencluster2# cd /export/home
root@ netnumencluster2# chmod –R 777 cluster
8. Add Application resource netnumen.
Select nms-grp in Relationship of Resources in NM Resource Group window as shown in Figure 266. Select Add Resource. The window for adding resource pops up. Select Application for Resource Type. Input netnumen in Resource Name text box. Select Enable. Set other attributes as follows:
Application netnumen (
StartProgram = "/netnumen/ums-svr/bin/console.sh"
StopProgram = "/export/home/cluster/offline_sol.sh"
MonitorProgram = "/export/home/cluster/moni_sol.sh"
)
9. Create Relationship of Resources in nms-grp.
Select nms-grp in Relationship of Resources in NM Resource Group window as shown in Figure 266. Select the Resource tab. Create relationship of resources according to relationship of resources in nms-grp. The relationship displays the sequence of starting or stopping resource. It is the foundation of ensuring normal running of resources.
The sequence of starting resources is: Start resources from the bottom up.
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 249
The sequence of stopping resources is: Stop resources from the top down.
10. Test nms-grp.
Test whether nms-grp is normal. Make sure database resource group oracle is in enabled status.
i. Select nms-grp in Relationship of Resources in NM Resource Group window as shown in Figure 266. Select online netnumencluster1. Observe whether nsm-grp resources and NM server is started normally. Start one NM client to verify whether NM server works normally.
ii. Verify whether nms-grp is switched normally. Select nms-grp in Relationship of Resources in NM Resource Group window as shown in Figure 266. Select switch to netnumencluster2. The resource group nms-grp stops on netnumencluster1 in sequence and then starts on netnumencluster2.
UNIX operating system does not display console interface when console is started via VCS. View NM server log or run NM client to verify whether NM server runs normally.
Establishing Relationship between Database Resource Group and NM Resource Group
To establish relationship between database resource group and NM resource group.
After configuring oracle database resource group and nmsgrpIt, it is required to establish the relationship between them, ensuring that NM server can start normally after database is started.
To establish relationship between database resource group and NM resource group, perform following steps:
1. Select ztevcs in VCS Cluster Administrator Interface window as shown in Figure 255. Select Service Groups tab.
Click button to create a line pointing from nms-grp to oracle resource group (Select nms and drag to oracle), as shown in Figure 267. It indicates that nms-grp relies on oracle database resource group.
Purpose
Preliminary Setup
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
250 Confidential and Proprietary Information of ZTE CORPORATION
F I G U R E 267 − R E L AT I O N S H I P B E T W E E N DAT AB AS E R E S O U R C E GR O U P OR AC L E AN D NM R E S O U R C E GR O U P N M S-G R P
2. Link Service Groups window appears as shown in Figure 268.
F I G U R E 268 − L I N K S E R V I C E GR O U P S
Select online global for Relationship, indicating that relationship between resources is global (whatever system the resource group runs on).
Select firm for Dependency Type, indicating to start oracle resource group firstly, then, nms-grp resource group.
3. Save all VCS Modifications.
END OF STEPS
Relationship between database resource group and NM resource group is established successfully.
Result
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 251
Take tests on NM dual system based on test rules.
NM Dual System Test Rules To verify NM dual system is working normally.
To verify NM dual system is working normally, perform the following steps:
1. Switch over resource groups manually. It is possible for resource group to have a switchover between two systems.
2. Stop oracle database process manually. Switch oracle resource groups.
i. Instances about oracle database
Perform the following operations on the host running oracle database.
#ps –ef | grep ora_smon or #ps –ef | grep ora_pmon
View oracle smon process or process number of prom process.
#kill –9 ora_smon or #kill –9 ora_pmon
Stop oracle smon process or pmon process. Oracle database switching between two systems is successful.
ii. Monitoring instances about oracle database
Perform the following operations on the host running oracle database.
#ps –ef | grep tnslsnr
View oracle monitoring process
#kill –9 oracle
Stop oracle monitoring process. Oracle database switching between two systems is successful.
3. Stop NM process manually. Switch over nms-grp between two systems automatically.
#ps –ef | grep java
#kill –9
Note: There is more than one java process. The process under the /netnumen/…./java path is the java process related to NM server. Stop all NM processes with the /netnumen/…./java path.
Follow-up Action
Purpose
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
252 Confidential and Proprietary Information of ZTE CORPORATION
Stop NM server java process. After a while, the dual system has a fault. Oracle database switching between two systems is successful.
4. Disconnect the network interface of the public network manually. Switch over resource.
5. Close the host running resource group. The resource group switch over to the other host automatically. After netnumencluster1 (netnumencluster2) is resumed, resource group is not switched over.
6. If the host running resource group is powered down, the resource group switches over to the other host automatically. After netnumencluster1 (netnumencluster2) is resumed, resource group is not switched over.
END OF STEPS
NM dual system is working normally.
System Security While NM system is running on Solaris operating system, it may be attacked. To enhance the security of NM system, it is required to do some settings and modifications on system.
General rules for system security are:
Install the latest system patch.
Close unnecessary services.
Delete unnecessary tools or modify rights.
The following suggestions are used to enhance the system security:
Delete the /.rhost file from both systems.
The /.rhost file is required for installing dual system. Delete this file after installing and debugging dual system. It may bring hidden trouble to safety.
Cancel the telnet right of root user.
Cancel the telnet right of root user after testing.
Ensure that it is set that root user is not permitted to login via telnet.
Edit /etc/default/login.
#vi /etc/default/login.
# If CONSOLE is set, root can only login on that device.
# Comment this line out to allow remote login by root.
#
CONSOLE=/dev/console
Result
Security Rules
Operation Suggestions
Chapter 5 VCS4.0 for UNIX
Confidential and Proprietary Information of ZTE CORPORATION 253
Set not to use ftp user list.
Forbid relevant users to perform ftp operations after testing.
Edit /etc/ftpusers(Solaris 9 is /etc/ftp/ftpusers)
#vi /etc/ftpusers
Add oracle, daemon, bin, sys, adm, lp, uucp, nuucp, listen, nobody, noaccess, and nobody4. Note that there is one separate line for each user name.
If oracle is the database user, perform the relevant modifications according to different database. If ftp operations are not required for NM-related user, disable ftp operations.
Close unnecessary services.
Close services below if NM system does not require them. NOTE: Restart the system to validate operations.
sendmail
#mv /etc/rc2.d/S88sendmail /etc/rc2.d/_S88sendmail
#mv /etc/rc2.d/S80lp /etc/rc2.d/_S80lp
#mv /etc/rc2.d/S80spc /etc/rc2.d/_S80spc
DMI
#mv /etc/rc3.d/S77dmi /etc/rc3.d/_S77dmi
Forbid dynamic route.
Forbid dynamic route if it is necessary.
#touch /etc/notroute
If hardware or software problems occur while installing dual system, contact the manufacturer for technical support:
SUN hotline technical support number: 800-810-3786. It is required to provide service number. The service number is on the back or side of the equipment. The format is S/N: FN******
Veritas (VCS) technical support number: 800-810-9771. The attached product certificate covers the service number.
Technical Support
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
254 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 255
A p p e n d i x A
Handling Common VCS Problems in UNIX
This appendix covers the following topics:
Modifying VCS Cluster Administrator Password
Checking Heartbeat
Checking Running Status
Starting VCS in Abnormal Status
Failed to Start Oracle Database after Switchover
Faulty VCS Resource Group or Resource
Uninstalling VCS
Modifying VCS Cluster Administrator Password To modify VCS cluster administrator interface password.
To modify VCS cluster administrator interface password, perform the following steps:
1. Select File User Manager on VCS Cluster Administrator window as shown in Figure 255. Select Change Password. Input the new password. Click OK.
2. Click the third icon in the tool bar to save the setting.
END OF STEPS
VCS cluster password is modified successfully.
Purpose
Steps
Result
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
256 Confidential and Proprietary Information of ZTE CORPORATION
Checking Heartbeat To check VCS heartbeat.
Check VCS heartbeat as follows.
#lltstat –n
LLT node information:
Node State Links
0 netnumencluster1 OPEN 2
* 1 netnumencluster2 OPEN 2
The above information shows that the heartbeat LLT of both hosts is normal. ‘*’ indicates that it is lltstat command sent from netnumencluster2.
#gabconfig –a
GAB Port Memberships
========================================
Port a gen 179d03 membership 01
Port h gen 179d05 membership 01
‘1’ indicates that GAB broadcast of two hosts heartbeat is normal.
Checking Running Status To check VCS running status.
Check VCS running status as follows.
# hastatus -sum
-- SYSTEM STATE
-- System State Frozen
A netnumencluster1 RUNNING 0
A netnumencluster2 RUNNING 0
It shows that both hosts are in normal running status.
Starting VCS in Abnormal Status To start VCS in abnormal status.
VCS can fail to start under the following conditions:
Purpose
Example
Result
Example
Result
Purpose
Example
Result
Purpose
Introduction
Appendix A Handling Common VCS Problems in UNIX
Confidential and Proprietary Information of ZTE CORPORATION 257
Restart the system after doing some settings on VCS cluster administrator interface while not saving settings. For instance, close VCS cluster administrator interface without save configurations. Or, terminate VCS process.
Modify main.cf file manually. Restart the system while the syntax is wrong. Or, terminate VCS process.
The following are the different solutions available:
Forget to save VCS configurations:
Execute the #hasys –force host name command on either host to make VCS works in normal running status.
It is better to execute this command on the host which has some settings done while without saving the settings.
Take netnumencluster1 as an example. The command is:
#hasys –force netnumencluster1
Then, execute the hagui command to start VCS cluster administrator interface.
The syntax for main.cf is wrong.
Modify main.cf. Execute the command below to verify whether the syntax for main.cf is correct.
#hacf –verify /etc/VRTSvcs/conf/config
Start VCS cluster administrator interface after modifying main.cf syntax.
Failed to Start Oracle Database after Switchover To provide solutions while it is failed to start oracle database after switchover.
If it is failed to start oracle database on one host after switchover, the error information is:
ORA-01157:Cannot identify/lock data file 11 -see DBWR trace file
ORA-01110: data file 11: '/export/home/oracle/product/9.2.0/dbs/uep.dbf
It is failed to identify the uep.dbf file, which is the NM database file created by the user.
The possible reason is that NM database is created on the local disk of one host (netnumencluster1, for instance), not on the shared disk array. When oracle database is switched over to netnumencluster2, it cannot read database data on netnumencluster1. Consequently, it is failed to start oracle database on netnumencluster2.
Solutions
Purpose
Error Information
Problem
Cause
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
258 Confidential and Proprietary Information of ZTE CORPORATION
The following instance provides the solutions:
NOTE: In this instance, oracle database is started successfully on netnumencluster1 and failed on netnumencluster2.
1. Switch oracle database to the host to start the database. Here, switch oracle database to netnumencluster1.
2. Delete database table space from local disk of netnumencluster1.
3. Make sure NM database script is correctly modified.
4. Create NM database to the shared disk array.
For detailed procedures, refer to the fifth step in the Configuring NetNumen N31 Program section.
Faulty VCS Resource Group or Resource To provide solutions while VCS resource group or resource is faulty.
If one resource is faulty, there is a red cross on it.
Delete most faulty resources manually. VCS system only removes a few faulty resources automatically, such as NIC resource error.
Method of removing faulty resource is:
Select the faulty resource. Right click on it. Select Clear Fault Auto.
If faulty resources are not removed from the host, it fails to enable Ora_Oracle resource on this host.
Oracle resource is switched over to netnumencluster2 when Ora_Oracle resource on netnumencluster1 is faulty. When netnumencluster2 is faulty, it is required to switch Ora_Oracle resource back to netnumencluster1. However, it fails to start oracle resource group on netnumencluster1 because the faulty Ora_Oracle resource on netnumencluster1 is not removed. Therefore, it is required to remove faulty resource manually.
Figure 269 shows that oracle resource group is faulty on netnumencluster 2. Then, it is switched over to netnumencluster1 and works normally on it.
NOTE: Remove the faulty resource from netnumencluster2 in time.
Solutions
Purpose
Error
Solutions
Method
Hidden Trouble
Example
Appendix A Handling Common VCS Problems in UNIX
Confidential and Proprietary Information of ZTE CORPORATION 259
F I G U R E 269 − OR AC L E R E S O U R C E G R O U P I S S W I T C H E D O V E R T O N E T N U M E N C L U S T E R 1 AN D W O R K S N O R M AL L Y .
Uninstalling VCS To uninstall VCS.
Save /etc/VRTSvcs/conf/config/main.cf file before uninstalling VCS. If types.cf file is modified, save it too.
To uninstall VCS, perform the following steps:
NOTE: Uninstall VCS from any host, for instance, netnumencluster1.
1. Terminate VCS process on all servers.
#./hastop -all –force
2. Uninstall server software and oracle agent software.
Logon to the system as root user. Execute commands below:
#cd /opt/VRTSvcs/install
#./uninstallvcs
Or, insert VCS CD into either host. Logon to the system as root user. Execute commands below:
#cd /cdrom/cdrom0/cluster_server
#./uninstallvcs
The system displays prompts as follows:
Enter the system names separated by spaces on which to uninstall VCS: netnumencluster1 netnumencluster2
Press [Return] to continue:
Do you want to uninstall package VRTSvcsor from netnumencluster1 which is dependent on package VRTSvcs? [y,n,q,?] (y) y
Do you want to uninstall package VRTSvcsor from netnumencluster2 which is dependent on package VRTSvcs? [y,n,q,?] (y) y
Purpose
Prerequisite
Steps
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
260 Confidential and Proprietary Information of ZTE CORPORATION
Are you sure you want to uninstall VCS packages? [y,n,q] (y) y
Uninstallation of Cluster Server has completed successfully.
END OF STEPS
VCS uninstalling is complete.
NOTE: While VCS server software and Oracle agent software are uninstalled from netnumencluster1, the VCS server software and Oracle agent software are uninstalled from netnumencluster2 automatically too.
Result
Confidential and Proprietary Information of ZTE CORPORATION 261
A p p e n d i x B
Common UNIX Operation Commands
This appendix covers the following topics:
File System Operation Commands
System Commands
Pack/unpack Commands
Important System Files
File System Operation Commands File system operation commands are listed in Table 22
T AB L E 22 − F I L E S Y S T E M OP E R AT I O N C O M M AN D T AB L E
Command Description Application
cd Modify directory -
ls Display directory and file information, similar to DOS command dir
-
mount Mount one device (such as a disk) to a directory
#mount /dev/dsk/c0t0d0s1 /test
more View files -
cat View files or combine multiple files to one file
# cat file1 file2 >file3
ln Create connection # ln file1 file2
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
262 Confidential and Proprietary Information of ZTE CORPORATION
Command Description Application
rm Delete one file; delete one directory and all contents in the directory where the parameter –R(r) exists
-
rmdir Delete one blank directory -
mkdir Create a directory -
cp Copy files -
mv Change the file name. Move one file or directory to another location
-
chgrp Modify the file group chgrp file (or directory name) parameter –R recurrence
chmod Modify file right chmod 755 file
chmod u+w file
chmod g+w file
chmod o+w
Parameter –R recurrence
chown Modify the file user -
wc Count bytes, characters and lines
-
pwd Display current directory -
find Find specified file find / -name filename -print & Find the specified file based on name at root directory. Execute the command on background and display the result on terminal.
tail Display file tail information tail -3 file Display from the last three lines; tail +3 file Display from the first three lines
ftp Enable ftp function -
Appendix B Common UNIX Operation Commands
Confidential and Proprietary Information of ZTE CORPORATION 263
System Commands System commands are listed in Table 23.
T AB L E 23 − SY S T E M C O M M AN D
Command Description Application
pkginfo View system patch pkginfo –i
df Show disk usage -
du Show file system; Show file size
-
uname View system information -
ps View process information -
kill Stop a process kill -9 120
kill -HUP 120 Kill the process and restart it.
pkill Stop the process according to process name
pkill httpd
netstat View network status -
ifconfig
Configure or view network interface parameters
ifconfig –a View
ifconfig eri0 136.1.56.170
Configure interface address (For nm7000)
ifconfig eri0 up(down)
ifconfig eri0 add
if IP address add a logical address.
admintool System administration tool -
hostname View host name -
who View login user -
date View or set system time -
env View system environment -
eject Eject CD driver -
clear Clear terminal screen information
-
| Pipe operator more inetd.conf|grep ftp
last View login and logout -
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
264 Confidential and Proprietary Information of ZTE CORPORATION
Command Description Application
route add Add route route add default 136.1.0.1 1
Add default gateway.
If the /etc/defaultrouter file exists, the system will set IP address in this file to be its gateway when system startup.
Pack/Unpack Command Pack/unpack commands are listed in Table 24.
T AB L E 24 − PAC K /U N P AC K C O M M AN D
Command Description Application
tar - tar -xvf *.tar Unpack
tar -cvf a.tar a Pack a to be a.tar.
pack Pack file with the suffix of .z
-
unpack Unpack the file. -
gunzip Unpack the file with the suffix of .gz
-
gzip Unpack the file with the suffix of .gz
-
compress compress -
uncompress uncompress -
zip zip -
unzip unzip unzip a.zip
Important System Files Import system files are listed in Table 25.
T AB L E 25 − IM P O R T AN T S Y S T E M F I L E S
File or directory Description Application
/etc/rc2.d Multi-user mode start file
-
/etc/rc0.d Close script -
Appendix B Common UNIX Operation Commands
Confidential and Proprietary Information of ZTE CORPORATION 265
File or directory Description Application
/etc/inetd.conf Network service configuration file
-
etc/default/login Login by telnet after commenting out CONSOLE=/dev/console
/etc/hosts and /etc/nodename
Save host information. -
/etc/defaultdomain
Save domain information.
-
/var/spool/cron/crontabs
User-related cron information
-
/etc/resolv.conf Domain name server IP. nslookup cannot be used unless the file exists.
-
/etc/passwd and /etc/shadow
User password file -
/etc/motd Prompt information after login
-
/etc/adm/sulog Record conversion between common user and root user.
-
/dev/null Null device. Cleaning up a file is the typical application.
cat /dev/null > file
cat /dev/null file
It is the best way to clean up a file. This operation does not have any influence on other processes whatever the file is open or not.
Note: The first letter for UNIX command is small letter.
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
266 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 267
A p p e n d i x C
Common Oracle Database Operations
This appendix covers the following topics:
Starting Oracle8i Database Service
Starting Oracle9i Database Service
Viewing Oracle Service Name
Viewing Database Table Space Name
Viewing Database User
Oracle Database Backup
Restoring Oracle Database
Starting Oracle8i Database Service Table 26 lists oracle8i database service commands.
T AB L E 26 − ST AR T I N G OR A C L E 8 I D AT AB AS E S E R V I C E C O M M AN D S
Command Description
# su – oracle Switch user to oracle; the password is oracle
$ svrmgrl Start oracle server manager
SVRMGR> connect internal
Connect to oracle manager
SVRMGR> startup Start oracle service
SVRMGR> exit Exit manager
$ lsnrctl Enter service monitoring management
LSNRCTL> start Start service monitoring
Commands
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
268 Confidential and Proprietary Information of ZTE CORPORATION
Command Description
LSNRCTL> exit Exit manager
Starting Oracle9i Database Service Table 28 lists Oracle9i database service commands.
T AB L E 27 − ST AR T I N G OR A C L E 9 I D AT AB AS E S E R V I C E C O M M AN D S
Command Description
# su – oracle Switch user to oracle; the password is oracle
$ lsnrctl start Start service monitoring
$ sqlplus /nolog Start sqlplus
> connect /as sysdba
Logon to sqlplus
> startup Start oracle database
> exit Exit sqlplus
Viewing Oracle Service Name The following example shows how to switch to oracle user. The command is executed as follows:
$ set
The environment variant for Oracle user, ORACLE_SID, is Oracle service name.
Viewing Database Table Space Name Generally, the NM database table space name is WEBNMSDB.
Table 28 lists the commands to view NM database table space name:
Commands
Command
Commands
Appendix C Common Oracle Database Operations
Confidential and Proprietary Information of ZTE CORPORATION 269
T AB L E 28 − V I E W I N G D AT A B A S E T AB L E S P AC E N AM E C O M M AN D S
Command Description
# su – oracle Switch user to oracle; the password is oracle
$ sqlplus system/** password for system user
SQL> select tablespace_name from user_tablespaces
Query
Viewing Database User Table 29 lists the commands to view database user:
T AB L E 29 − V I E W I N G D AT A B A S E U S E R C O M M AN D S
Command Description
# su – oracle Switch user to oracle; the password is oracle
$ sqlplus system/** password for system user
SQL> select username from dba_users
Query
Oracle Database Backup To take the backup oracle database execute the following command
# su – oracle: Switch user to oracle. (Password: oracle)
$ exp : Export database.
NOTE: The system asks some questions. Use default values for them except user name and password for database. Put the backup file to installation directory, such as /export/home/oracle.
Restoring Oracle Database To restore oracle database use imp command.
Commands
Commands
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
270 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 271
A p p e n d i x D
Abbreviations
Abbreviation Full Name
ACL Access Control List
ADSL Asymmetric Digital Subscriber Line
ATM Asynchronous Transfer Mode
CPU Central Processing Unit
DSL Digital Subscriber Line
DSLAM Digital Subscriber Line Access Multiplexer
HTML Hyper-Text Markup Language
HTTP Hypertext Transfer Protocol
IP Internet Protocol
LAN Local Area Network
MAC Media Access Control
MODEM Modulator-Demodulator
PC Personal Computer
PPP Point-to-Point Protocol
PVC Permanent Virtual Circuit
QoS Quality of Service
RAID Redundant Array of Independent Disks
RAM Random Access Memory
RMI Remote Method Invocation
RMON Remote Network Monitoring
SNMP Simple Network Management Protocol
SQL Structured Query Language
TFTP Trivial File Transfer Protocol
VCI Virtual Channel Identifier
VLAN Virtual Local Area Network
VPI Virtual Path Identifier
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
272 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 273
Figures
Figure 1 – Space For User Partition ..................................... 12 Figure 2 – Admin Tool: Groups ........................................... 14 Figure 3 – Admintool: Add Group........................................ 15 Figure 4 – Admintool: Add User Window .............................. 15 Figure 5 – Admintool: Add User Window .............................. 17 Figure 6 − Show Hidden Objects......................................... 18 Figure 7 – Text Editor – .profile Window .............................. 19 Figure 8 − Run Window..................................................... 20 Figure 9 − Prompt Window ................................................ 21 Figure 10 − Extracting Files ............................................... 21 Figure 11 − Installation Finished......................................... 22 Figure 12 – Terminal Window............................................. 23 Figure 13 – Listening Process Window ................................. 23 Figure 14 − Download Patch .............................................. 26 Figure 15 − PATCH Searching ............................................ 26 Figure 16 − Patch Searching Result..................................... 27 Figure 17 − SQL Server 2000 Installation Screen .................. 31 Figure 18 − SQL Server 2000 Installation Screen .................. 32 Figure 19 − Install Components Window.............................. 32 Figure 20 − Installation Preparations Window....................... 33 Figure 21 − Welcome Window ............................................ 33 Figure 22 − Computer Name Window .................................. 33 Figure 23 − Installation Selection Window............................ 34 Figure 24 − User Information Window ................................. 34 Figure 25 − Software License Agreement Window ................. 35 Figure 26 − Installation Definition Window ........................... 35 Figure 27 − Instance Name Windows .................................. 36 Figure 28 − Installation Types Window ................................ 36 Figure 29 − Service Accounts Window ................................. 37
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
274 Confidential and Proprietary Information of ZTE CORPORATION
Figure 30 − Authentication Mode Window ............................ 37 Figure 31 − Start Copying File Window................................ 38 Figure 32 − Choose Licensing Mode Window......................... 38 Figure 33 − INSTALLATION Progress Window ....................... 39 Figure 34 − Starting Server Window ................................... 39 Figure 35 − Updating System Window................................. 39 Figure 36 − Installation Complete Dialog Box ....................... 40 Figure 37 – NetNumen Installation (Windows) ...................... 42 Figure 38 – Selecting Language – NetNumen........................ 43 Figure 39 – Directory Selection in NetNumen........................ 43 Figure 40 – Extracting Platform Files ................................... 44 Figure 41 – NetNumen Install – NMS Client .......................... 45 Figure 42 – Selecting Language - NMS Client........................ 45 Figure 43 – Directory Selection NMS Client........................... 46 Figure 44 – Extracting Platform Files NMS Client ................... 46 Figure 45 – Running NMS Config Center .............................. 48 Figure 46 – NetNumen Config Center Window....................... 48 Figure 47 – Basic Information Tab ...................................... 49 Figure 48 – NE Module Tab ................................................ 50 Figure 49 – Database Tab.................................................. 51 Figure 50 – Database Data Type Tab................................... 51 Figure 51 – Database System Administration Name And Password ........................................................................ 52 Figure 52 – Database IP Address Window ............................ 53 Figure 53 – Test Connection Database................................. 54 Figure 54 – Optimize Database........................................... 54 Figure 55 – FTP Service Tab............................................... 55 Figure 56 – Add FTP User Window....................................... 56 Figure 57 – Modify FTP User Windows ................................. 56 Figure 58 – Information Dialog Box..................................... 57 Figure 59 – Information Dialog Box..................................... 57 Figure 60 – Client Update Tab ............................................ 58 Figure 61 – Policy Configuration Tab ................................... 59 Figure 62 – Syslog Info Tab ............................................... 62 Figure 63 – Adding Syslog Server Window ........................... 62 Figure 64 – Add NE Type ................................................... 63 Figure 65 – Modify NE Type ............................................... 63
Figures
Confidential and Proprietary Information of ZTE CORPORATION 275
Figure 66 – Add Syslog Server ........................................... 63 Figure 67 – Modify Syslog Server........................................ 64 Figure 68 – Delete Sylog Server ......................................... 64 Figure 69 – Shortcut Tab ................................................... 65 Figure 70 – Other Tab ....................................................... 66 Figure 71 – Advance Tab ................................................... 67 Figure 72 – Save Other Information .................................... 67 Figure 73 – Info Dialog Box................................................ 68 Figure 74 – Analog Input Parameters Configuration Tab ......... 69 Figure 75 – Add Analog Parameters .................................... 69 Figure 76 – Modify Analog Input Parameters Configuration Tab70 Figure 77 – Info ............................................................... 70 Figure 78 – Digital Input Parameters Configuration Tab.......... 71 Figure 79 – Add Input Digital Parameters Window ................. 71 Figure 80 – Modify Digital Input Parameters Window ............. 72 Figure 81 – Delete Digital Input Parameters ......................... 72 Figure 82 – Digital Output Parameters Configuration Tab ....... 73 Figure 83 – Add Output Digital Parameters Window............... 73 Figure 84 – Modify Digital Output Parameters Configuration.... 74 Figure 85 – Delete Digital Output Parameters ....................... 74 Figure 86 – Power Parameters Configuration Tab .................. 75 Figure 87 – Add Power Parameters Window.......................... 75 Figure 88 – Modify Power Parameters Configuration .............. 76 Figure 89 – Delete Power Parameters .................................. 76 Figure 90 – Import (Export) Configuration Data Tab .............. 77 Figure 91 – Import Data Window ........................................ 77 Figure 92 – Export Data Window......................................... 78 Figure 93 – Config Center.sh.............................................. 79 Figure 94 – NetNumen Install............................................. 79 Figure 95 – NetNumen Install............................................. 80 Figure 96 – NetNumen Install............................................. 80 Figure 97 – NetNumen Install............................................. 81 Figure 98 – Config Center Starts......................................... 81 Figure 99 – Config Center.sh.............................................. 82 Figure 100 – NetNumen Install ........................................... 83 Figure 101 – NetNumen Install ........................................... 83
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
276 Confidential and Proprietary Information of ZTE CORPORATION
Figure 102 – NetNumen Install ........................................... 84 Figure 103 – NetNumen Install ........................................... 84 Figure 104 – Config Center Starts ....................................... 85 Figure 105 – Configuration Center.sh .................................. 86 Figure 106 – NetNumen Configuration Center Tab................. 87 Figure 107 – Basic Information Tab..................................... 88 Figure 108 – NE Module Tab .............................................. 89 Figure 109 – Module Deploy............................................... 89 Figure 110 – Database Tab ................................................ 90 Figure 111 – Database Data Type Tab ................................. 90 Figure 112 – Database System Administration Name And Password ........................................................................ 91 Figure 113 – Database IP Address Window........................... 92 Figure 114 – Test Connection Database ............................... 93 Figure 115 – FTP Service Tab ............................................. 94 Figure 116 – Add FTP User Window..................................... 94 Figure 117 – Modify FTP User Windows................................ 95 Figure 118 – Information Dialog Box ................................... 95 Figure 119 – Information Dialog Box ................................... 95 Figure 120 – Client Update Tab .......................................... 96 Figure 121 – Policy Configuration Tab.................................. 97 Figure 122 – Syslog NBI Info Tab ..................................... 100 Figure 123 – Adding Syslog Server Window........................ 100 Figure 124 – Add NE Type ............................................... 101 Figure 125 – Modify NE Type............................................ 101 Figure 126 – Add Syslog Server........................................ 101 Figure 127 – Modify Syslog Server .................................... 102 Figure 128 – Delete Sylog Server ..................................... 102 Figure 129 – Short Cut Tab.............................................. 103 Figure 130 – Other Tab ................................................... 104 Figure 131 – Advance Tab ............................................... 104 Figure 132 – Save Other Information ................................ 105 Figure 133 – Info Dialog Box............................................ 105 Figure 134 – Analog Input Parameters Configuration Tab ..... 106 Figure 135 – Add Analog Parameters................................. 106 Figure 136 – Modify Analog Input Parameters Configuration Tab................................................................................... 107
Figures
Confidential and Proprietary Information of ZTE CORPORATION 277
Figure 137 – Information................................................. 107 Figure 138 – Digital Input Parameters Configuration Tab...... 108 Figure 139 – Add Input Digital Parameters Window ............. 108 Figure 140 – Modify Digital Input Parameters Window.......... 109 Figure 141 – Delete Digital Input Parameters ..................... 109 Figure 142 – Digital Output Parameters Configuration Tab.... 110 Figure 143 – Add Output Digital Parameters Window ........... 110 Figure 144 – Modify Digital Output Parameters Configuration 111 Figure 145 – Delete Digital Output Parameters ................... 111 Figure 146 – Power Parameters Configuration Tab............... 112 Figure 147 – Add Power Parameters Window ...................... 112 Figure 148 – Modify Power Parameters Configuration........... 113 Figure 149 – Delete Power Parameters .............................. 113 Figure 150 – Import (Export) Configuration Data Tab .......... 114 Figure 151 – Import Data Window .................................... 114 Figure 152 – Export Data Window..................................... 115 Figure 153 − Dual Hot Backup NM System ......................... 119 Figure 154 – Disk Array Connections ................................. 120 Figure 155 − Configuring Heartbeat Connection.................. 123 Figure 156 − Configuration Server Guide ........................... 124 Figure 157 − Creating Directory Tree or Sub-tree ............... 125 Figure 158 − Specifying New Domain Name ....................... 125 Figure 159 − Setting Database and Log File Location........... 126 Figure 160 − Confirming DNS Configuration ....................... 126 Figure 161 − Configuring DNS.......................................... 127 Figure 162 − Permissions ................................................ 127 Figure 163 − Specifying Administrator Password................. 128 Figure 164 − Configuring Active Directory.......................... 128 Figure 165 − Completing the Active Directory Installation Wizard................................................................................... 129 Figure 166 − Prompt of Restarting System......................... 129 Figure 167 − Welcome Interface....................................... 130 Figure 168 − Domain Controller Type................................ 130 Figure 169 − Network Credentials..................................... 131 Figure 170 − Select Product to Install................................ 132 Figure 171 − Select Install Type ....................................... 132 Figure 172 − License ...................................................... 133
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
278 Confidential and Proprietary Information of ZTE CORPORATION
Figure 173 − Options Selections 1 .................................... 133 Figure 174 − Options Selections 2 (with two heartbeat network cards)........................................................................... 134 Figure 175 − Options Selections 3 .................................... 134 Figure 176 − Options Selections 4 .................................... 135 Figure 177 − Computer Selection ..................................... 135 Figure 178 − Validation................................................... 136 Figure 179 − Install Report.............................................. 136 Figure 180 − Install Process............................................. 137 Figure 181 − Install Summary.......................................... 137 Figure 182 − Reboot Remote Computers ........................... 138 Figure 183 − Reboot Status ............................................. 138 Figure 184 − Thank you for using VERITAS Storage Foundation HA 4.3 for Windows Interface........................................... 139 Figure 185 − Prompt Dialogue Box, Asking Whether to reboot your local computer or not............................................... 139 Figure 186 − VERITAS Enterprise Administrator.................. 140 Figure 187 − localhost-Write Disk Signature....................... 141 Figure 188 − localhost-New Dynamic Disk Group Wizard 1 ... 141 Figure 189 − localhost-New Dynamic Disk Group Wizard 2 ... 142 Figure 190 − localhost-New Dynamic Disk Group Wizard 3 ... 142 Figure 191 − Creating Hard disk Group Completed.............. 143 Figure 192 − localhost-New Volume Wizard 1..................... 144 Figure 193 − localhost-New Volume Wizard 2..................... 144 Figure 194 − localhost-New Volume Wizard 3..................... 145 Figure 195 − localhost-New Volume Wizard 4..................... 145 Figure 196 − localhost-New Volume Wizard 5..................... 146 Figure 197 − Starting VCS Configuration Wizard ................. 147 Figure 198 − Welcome Interface....................................... 147 Figure 199 − Configuration Options .................................. 148 Figure 200 − Domain Selection 1...................................... 148 Figure 201 − Domain Selection 2...................................... 149 Figure 202 − Discovering System ..................................... 149 Figure 203 − VCW Options .............................................. 150 Figure 204 − Cluster Details ............................................ 150 Figure 205 − Validate Systems......................................... 151 Figure 206 − NIC Selection.............................................. 151
Figures
Confidential and Proprietary Information of ZTE CORPORATION 279
Figure 207 − Set Service Network Card to be Low Priority .... 152 Figure 208 − Service Account........................................... 152 Figure 209 − Security ..................................................... 153 Figure 210 − Summary ................................................... 153 Figure 211 − Finish......................................................... 154 Figure 212 − SQL Server Manager .................................... 156 Figure 213 − Changing SQL Server Automatic Startup to be Manual Startup .............................................................. 156 Figure 214 − Starting VCS Management ............................ 157 Figure 215 − Select Configuration Option........................... 158 Figure 216 − Service Group Configuration.......................... 158 Figure 217 − SQL Server Instance Selection....................... 159 Figure 218 − Detail Monitoring Configuration...................... 159 Figure 219 − Registry Replication Path .............................. 160 Figure 220 − Virtual Server Configuration .......................... 160 Figure 221 − Servie Group Summary ................................ 161 Figure 222 − Configuration Complete ................................ 161 Figure 223 − Starting VCS Management ............................ 162 Figure 224 − Connectivity Configuration ............................ 163 Figure 225 − Login ......................................................... 163 Figure 226 − Cluster Explorer .......................................... 163 Figure 227 − AutoStartList............................................... 164 Figure 228 − ForceUnmount ............................................ 165 Figure 229 − Modified Configuration.................................. 165 Figure 230 − NetNumen NM Configuration Center ............... 166 Figure 231 − Add Service Group....................................... 168 Figure 232 − Creating NM Resource Group (nms-grp).......... 168 Figure 233 − Add Resource.............................................. 169 Figure 234 − Running ..................................................... 170 Figure 235 − Creating VMDriveInfo.txt File......................... 170 Figure 236 − d:\ VMDriveInfo.txt...................................... 171 Figure 237 − nms-grp-VMDg Resource .............................. 171 Figure 238 − nms-grp-MountV Resource............................ 172 Figure 239 − proxy_NIC Resource .................................... 173 Figure 240 − UMS NM Platform Server Console................... 176 Figure 241 − Add NM Resource ........................................ 176 Figure 242 − Set RestartLimit to be 3................................ 177
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
280 Confidential and Proprietary Information of ZTE CORPORATION
Figure 243 − NM Programme Resource.............................. 178 Figure 244 − Adding Relationship ..................................... 178 Figure 245 − Service Group ............................................. 179 Figure 246 − Link Service Groups ..................................... 180 Figure 247 − All VCS Resources are Started Normally.......... 180 Figure 248 − Finding Program.......................................... 181 Figure 249 − Modifying Options........................................ 181 Figure 250 − License Interface ......................................... 182 Figure 251 − Dual Hot Backup NM System......................... 192 Figure 252 − Opening VCS Cluster Manager Interface.......... 227 Figure 253 − Creating a New Cluster................................. 227 Figure 254 − Cluster Monitor Interface After VCS is Created . 228 Figure 255 − VCS Cluster Administrator Interface ............... 228 Figure 256 − Importing Oracle Type ................................. 229 Figure 257 − Adding Oracle Resource Group ...................... 230 Figure 258 − Relationship between Oracle Resource Group and Resources ..................................................................... 230 Figure 259 − Adding Resource ......................................... 231 Figure 260 − AutoStartList Property.................................. 232 Figure 261 − Edit Attribute .............................................. 233 Figure 262 − Creating Resource Relationship...................... 236 Figure 263 − NetNumen NM Configuration Center ............... 241 Figure 264 − Starting NM Server Test ............................... 243 Figure 265 − Adding NM Server Resource Group nms-grp .... 244 Figure 266 − Relationship of Resources in NM Resource Group................................................................................... 244 Figure 267 − Relationship between Database Resource Group Oracle and NM Resource Group nms-grp............................ 250 Figure 268 − Link Service Groups ..................................... 250 Figure 269 − Oracle resource group is switched over to netnumencluster1 and works normally. ............................. 259
Confidential and Proprietary Information of ZTE CORPORATION 281
Tables
Table 1 − Chapter Summary .................................................i Table 2 − Typographical Conventions .................................... ii Table 3 − Mouse Operation Conventions ............................... iii Table 4 – Network Types .....................................................1 Table 5 − Equivalent NE Example .........................................2 Table 6 − NT Server Configuration ........................................3 Table 7 − Outsourcing Software ...........................................3 Table 8 − Accessories .........................................................4 Table 9 − Hardware Platform ...............................................4 Table 10 − Outsourcing Software..........................................5 Table 11 − Accessories........................................................5 Table 12 − Hardware Platform..............................................6 Table 13 − Outsourcing Software..........................................6 Table 14 − Accessories........................................................7 Table 15 − Hardware Platform..............................................7 Table 16 − Outsourcing Software..........................................8 Table 17 − Accessories........................................................8 Table 18 − Firewall .............................................................9 Table 19 − Disk Partition ................................................. 186 Table 20 − c1t0d0 Disk Partition....................................... 189 Table 21 − Disk Partition ................................................. 192 Table 22 − File System Operation Command Table.............. 261 Table 23 − System Command .......................................... 263 Table 24 − Pack/Unpack Command................................... 264 Table 25 − Important System Files ................................... 264 Table 26 − Starting Oracle8i Database Service Commands ... 267 Table 27 − Starting Oracle9i Database Service Commands ... 268 Table 28 − Viewing Database Table Space Name Commands 269 Table 29 − Viewing Database User Commands ................... 269
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
282 Confidential and Proprietary Information of ZTE CORPORATION
This page is intentionally blank.
Confidential and Proprietary Information of ZTE CORPORATION 283
Index
Adding Oracle Resource Group.................................. 229
Analog Input Parameters Configuration ...........68, 105
Backup Domain................. 129 Basic Information.......... 49, 87 Client Update ............... 57, 96 Configure SQL Server Startup
Type............................ 155 Configuring Database ..........23 Configuring Domain........... 124 Configuring NetNumen N31 NM
Resources .................... 165 Configuring NetNumen N31
Program....................... 238 Configuring Network.......... 122 Configuring NMS Config Center
....................................47 Configuring Resources in Oracle
Resource Group ............ 231 Configuring sqlserver Resources
.................................. 162 Creating Disk Array Logical
Partition....................... 139 Creating Disk Group .......... 140 Creating NM Server Resource
Group .......................... 243 Creating Oracle Resource Group
.................................. 229 Creating Volume ............... 143 Database i, 50, 51, 54, 89, 117,
125, 154, 203, 249 Digital Input Parameters
Configuration ...........70, 107 Digital Output Parameters
Configuration ...........72, 109 Disk Array Connections ...... 119 Disk Array Partition ........... 191 Dividing Disk Array............ 122 Dividing SUN A1000 Disk Array
.................................. 197 Dual Hot Backup Configuration
Requirements ............... 185 Dual System Requirements for
UNIX ...............................7 Dual System Requirements for
Windows ..........................6 FTP Service .................. 55, 93 Hardware......................... 119 Hardware Connection.. 119, 191 Hardware Firewall .................9
Hardware Requirements 11, 186 Import (Export) Configuration
Data....................... 76, 113 Importing Oracle Type....... 229 Installation Preparation........ 13 Installing Latest Solaris9 Patch
.................................. 190 Installing NM Program ....... 237 Installing NMS.................. 156 Installing NMS Client ......44, 82 Installing NMS Client and
Server ......................42, 78 Installing Oracle 9i .............. 20 Installing Oracle Database on
netnumencluster1 ......... 204 Installing Oracle Database on
netnumencluster2 ......... 204 Installing Oracle9i Service Pack
.................................... 25 Installing VCS Oracle Agent
Software...................... 226 Installing VCS Patch .......... 226 Installing VCS Software ..... 208 Installing VCS4.0 .............. 208 Main Domain.................... 124 Modifying Service IP of Oracle
Database as Floating IP.. 207 NE Module ....................50, 88 NM Program Running Test.. 242 NM Resource Group........... 237 Oracle 9i Post Installation
Check............................ 22 Other ..................... 3, 65, 103 Policy Configuration .......58, 96 Power Parameters
Configurations ......... 74, 111 Preparations before Installation
.................................. 203 Requirements for Disk Array
Partition....................... 192 Running Config Center....47, 86 Setting Network ............... 200 Short Cut......................... 103 Shortcut ............................ 65 Single System Requirements for
UNIX ...............................4 Single System Requirements for
Windows..........................3 Software Requirements. 12, 187 Solaris9 Oerating System
Installation................... 187
NetNumen N31 (V4.2.0) Network Management System (General) User Manual (Volume I)
284 Confidential and Proprietary Information of ZTE CORPORATION
Starting VCS Cluster Manager...................................227
SUN 3310 Disk Array Partition...................................193
System Log Information . 61, 99 Test Dual Systems.............183 Test Rules for Local Dual Hot
Backup System..............183 Test Single System............182
Testing Oracle Resource Group.................................. 236
Upgrading VCS License ...... 181 VCS License ..................... 181 VCS Software Configuration 162 VCS Software Configuration -
Create Cluster............... 146 VCS Software Configuration –
Create SqlServer Resource Group .......................... 157