ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

INDIVIDUALINNOVATIVEENERGY-SAVING

THE SHOP CLASSICZEPHYR EC

ZEPHYRZEPHYR

ZEPHYR

Page 2: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

Attractive intake grillewith micro-intake grille behind it

Access panelwith hidden screws

+

+

+ Self-supporting sheet steelhigh-quality powder coated

ApplicationsZephyr EC is the classic model for use in shops. Installation-ready unit which can be used for many applications, with 4 installation variants. Free-hanging, flush with the ceiling as a cassette, installation in suspended ceilings with sliding supports, and, on request also available as a floor-mounted vertical unit.

The housingSelf-supporting sheet steel. Screws are not visible.High-quality powder coating, RAL 9016 as standard (traffic white). Other colours are available. Access panel hidden behind the intake grille. Aerodynamically-optimised aluminium dis-charge fin (naturally anodised), flush with the underside of the unit and adjustable in 5 stages. Perforated metal intake grille (same colour as the unit) with micro grille behind it as an intake filter.

Heating mediaHeat exchangers for different heating mediaLPHW – for normal temperature LPHW 70/50°C and low-tem-perature LPHW 60/40°C, other temperatures available on request. DX – DX register soldered under nitrogen for operation with heat pumps. High-quality heat exchanger made from copper tubes, with pressed-on, extra-strong aluminium fins. ELECTRO: Series M : Ceramic 400V PTC elements Series L: 3-stage heat exchanger 400V, spiral form, corrosion resistant, with thermal overheating protection and switch-off delay.

MaintenanceEasy to clean (micro grille) without opening the unitby simply vacuuming the intake grille. Discreet secured access panel hidden on the lower side of the unit (hinges on one side) – easy to open.

THE SHOP CLASSICZEPHYR EC

Discharge fincan be adjusted in 5 stages

+

2

Page 3: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

Advantages at a glanceMade in Germany

ErP conform / EC fans

Certified by TÜV-Süd

Robust, self-supporting sheet steel

Individual colours available

4 installation variants

Individual unit lengths up to 3000 mm

Service friendly thanks to filterless micro-intake grille

Simple to install

Aerodynamically optimised discharge fin

Different heating media possible

+

+

+

+

+

+

+

++

+

+

EC fansThe efficiency of the EC fans used by TEKADOOR is > 90% under partial load operation. This is 30–35% higher than for conventional AC fans. This does not just increase the efficiency, but also reduces the operating costs. The individually-driven EC fans with integrated motor protection can intake air in both directions. They have vibration-free bearings and are controlled by a PWM signal (pulse width modulation) – and for the DX with 0-10 V. They do not just comply with Directive ErP, but actually exceed this standard.

MountingSimple mounting thanks to the rivet nuts (M8) incorporated on the upper side of the unit and optionally-available assembly materials. In the standard version, the unit does not need to be opened for electrical connection. Connection terminals for the voltage supply, as well as the connectors for the control unit and parallel operation can be accessed from the outside.

Control Electronic TEKADOOR GTC EC control unit, multifunctional with touch display, including an optional ModBus interface A GTC 1 EC control unit is used as standard for models with LPHW heating. A GTC E EC or a GTC PTC EC control unit is used for models with electrical heating. The units come with 20 m preassembled and shielded data cable. The GTC 1 EC 5-stage control unit includes the ability to switch from manual to automatic and from summer mode to winter mode as standard. A solenoid valve of up to 2.5 A can be connected as an option for the winter mode. With the standard GTC E EC control unit, the airflow can be selected manually in 5 stages and the heating capacity – depending on the fan level – can be selected manually in 3 stages. The GTC PTC EC control unit for PTC heating elements switches the heating level automatically to the preselected fan level. Each control unit includes a manual to automatic mode switch and a potential-free contact for enabling via any on-site BMS or BEMS. A choice of 5-stage or stepless fan operation is offered as standard.A maximum of 10 units can be connected in parallel. 3

Page 4: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

Connections

Heating connections – flow and return - on top of the unit as standard for easy connection to the on-site heating system. Op-tionally, the connections can also be to move - top right or side

Connection box (LPHW)

Simple electrical connection via connection box (voltage supply 230V/50Hz on the top of the unit); Optionally, the connections can also be to move

Exception:Electrical units with a heating capacity greater than 22,5 kW.

DETAILSZEPHYR EC

4

Page 5: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

Data cable connection/interface

Simple, standard plug and play connection of the data cable and an optional solenoid valve on the top side of the unit. The connection can be offset on request.

Control:Input for the data cable to the control unit.

Auxiliary:Output for parallel operation with other units.

Discharge fin

The shielding performance of the door air curtain system is opti-mised by adjusting the discharge fin. The fin can be adjusted in 5 stages. During the heating period, the discharge fin should be tilted outwards by 10 to 15 degrees to prevent cold air coming in from the outside. In contrast, during operation in the summer, the fin is tilted inwards, so that the cooled indoor air cannot escape.

5

Page 6: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

ZEPHYR

ZEPHYR ECINSTALLATION VARIANTS

6

Page 7: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

ZEPHYR

Free-hanging

A = VARIABLE UNIT LENGTH

FRONT VIEW

BOTTOM VIEW

SIDE VIEW

TOP VIEW

Connection-ready free-hanging door air curtain unit for visible installation directly above the door.Ambient air intake is at the front, on the room side.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

Optional:side connections

connection box60

in

out

30

60

85

50

25

30

70

A

46035 295

Vorbereitung fürVerschraubung M 20

Platinein

out

Einnietmuttern M8

75 45

60100

40

260

Anschlussboxconnection box

provision for screwconnection 20 mm

circuit board

rivetting nut M8Attention! Measure will change for model Zephyr LX / LXX from 260 mm to 450 mm and from 460 mm to 715 mm and revetting nut M8 will change to M10.

**

*

*

7

Page 8: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

ZEPHYR

Cassette

FRONT VIEW

BOTTOM VIEW

TOP VIEW

SIDE VIEW

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

Connection-ready door air curtain unit with integrated intake chamber on the underside and surrounding frame for installation flush with the ceiling. Ambient air intake is from the underside, on the room side. Freely accessible maintenance panel.

connection box

9 mm Langlochfür Befestigung

verschiebbar

80

50

M8

40

Befestigung nur bei über 2m GeräteM8 Einnietmutter unter der Lasche35

25

700

260

AA+50

LuftaustrittRevision

650

LuftaustrittRevision

OUT

IN

Platine

80

260

365390

12540

Vorberei-tungVerschrau-bung M20

DurchführungTemperatur-fühler

80700

MEASURE A:

950 mm

1450 mm

1950 mm

2450 mm

A = VARIABLE UNIT LENGTH

hidden fixing screw for inspection

prepared for using in a suspended ceiling

fitting for units bigger than 2m

9 mm long hole for fitting

movable

air outlet

air outlet

inspection panel

inspection panel

circuit board

provision for screw connection20 mm

performancefor temperaturesensor

Attention! Measure will change for model Zephyr Cassette LX / LXX from 260 mm to 440 mm and from 700 mm to 1270 mm and revetting nut M8 will change to M10.

*

8

Page 9: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

ZEPHYR

Suspended ceiling unitFRONT VIEW

BOTTOM VIEW

TOP VIEW

SIDE VIEW

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

Connection-ready door air curtain unit with integrated intake chamber on the underside. Intake and discharge sliding supports for installation in a suspended ceiling. Only the intake and discharge grilles are visible from below. Ambient air intake is from the under-side, on the room side.CAUTION: The maintenance panel is on the underside of the unit. Therefore, it is essential that the suspended ceiling in which the unit is installed can be disassembled.

Optional:side connection

connection box

A = VARIABLE UNIT LENGTH

130-210

60

out

in

60

50

85

M25 + M20

351

26015

210 260 25

3020 20

75120

Verschraubung

A

720

35 295Vorbereitung für

Verschraubung M 20

Platine

Einnietmuttern M8

inout

75 50

60100

40Anschlussboxconnection box

circuit board

provision for screwconnection 20 mmrivetting nut M8

Attention! Measure will change for model Zephyr LX / LXX from 260 mm to 580 mm and from 720 mm to 1100 mm and revet-ting nut M8 will change to M10.

*

**

*

9

Page 10: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

STANDARD CIRCUIT DIAGRAM FOR LPHW (PUMPED WARM WATER)

ZEPHYR EC

230V/ 50Hz

3

CONTROL

F 16 AT

L N PE

Platine EC

Anschlußbox

bauseitig

Erdung, Nullung oderSchutzschaltung nachden Vorschriften desVDE und des zuständ.EVU ausführen.

Technische Änderungen vorbehalten

Störun

g pot.

-frei

Betrie

b pot.

-frei

1 211 12 133 4 514 15

0

zum Steuerteil (CONTROL)Adresse 1-9

8

AUXILIARNL2 PE

230V / 50Hz

Magnetventil(OPTIONAL)

L PEN

8

PENL2

internAUX MON

07.03.2017lagezeichnet/signet

TeileGruppevonPos.

Werkstoff Maßstab

Blatt

Erstelldatum

GTM EC MOD Bus 170307Kunde

BenennungName

Kundenzeichnung Nr.:

DatumName

1 von 1

6 716 17 8 9 10 1918 20

CPU

AdressSchalter0 = MASTER1 - 9 = SLAVE

5

1 23

4

9

87 6

nicht

beleg

t

nicht

beleg

t

nicht

beleg

t

nicht

beleg

t

Fros

tschu

tzthe

rmos

tatop

tiona

l

Standard Anschlusskabel(20 m) mitRJ-45 Stecker

1M

PENL1

zu weiterenVentilatoren

blau/blue

gelb/yellow

weiss/white

rot/red

4

321

RJ 45

MOD Bus 1 2 3 4

ON

optio

nal

ext. S

ignalg

eber

DDC-

Fre

igab

e op

tiona

l

Y PWM

0 V

+10 V

imp.

ModBusinterface(optional)

230V/ 50Hz

3

CONTROL

F 16 AT

L N PE

PCB EC

Connecting box

Main switch and fusesto be installed by thirdparties must complyto all applicable rules andrequirements!

Technical changes reserved

1 211 12 133 4 514 15

0

to input (CONTROL) next PCBAddress 1-9

8

AUXILIARNL2 PE

230V / 50Hz

Magnetic valve(OPTIONAL)

L PEN

8

PENL2

internAUX MON

02.01.2019lagezeichnet/signet

TeileGruppevonPos.

Werkstoff Maßstab

Blatt

Erstelldatum

GTC I EC 190102Kunde

BenennungName

Kundenzeichnung Nr.:

DatumName

1 von 1

6 716 17 8 9 10 1918 20

CPU

Addressswitch0 = MASTER1 - 9 = SLAVE

5

1 23

4

9

87 6

ext. C

ontac

t

fault

Opera

tion

Fros

t prot

ectio

n the

rmos

tat

not u

sed

not u

sed

nicht

beleg

t

optio

nal

optio

nal

Standard suppledshielded datacable(20 m) withRJ-45 connectors

1M

PENL1

next Fan

blau/blue

gelb/yellow

weiss/white

rot/red

4

Room

temp.

sens

orop

tiona

l

Room temperature. Sensor installed

q

BMS

On/O

ff

Y 0-10 V

0 V

+10 V

imp.

Timeroff

Fr 21.09.201807:52

Heat level0 / 0

AutomaticHand

Room Temp10°C

Fan level0 / 0

CONTROL UNIT GTC 1 ECMultilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control unit with touch display is a choice between 5-stage or stageless fan control, which can be selected individually by the operator. The relevant operating modes and symbols are arranged clearly on the colour display. The date, time and room temperature are shown as standard. The room temperature is monitored via an internal temperature sensor in the control unit as standard.

An easy-to-navigate menu offers a selection of different operating modes:Hand – manual operationAuto AS – automatic operation via cool down protectionAuto RT – automatic operation via room temperatureAuto TK – automatic operation via door contactAuto Kombi – option to combine all individual automatic modes

An enabling contact and potential-free operation and malfunction signals are provided for control via an on-site BMS or BEMS. Errors and faults are displayed with a red „warning“ sign. By coding the control boards differently, up to 10 door air curtains can also be operated in parallel with 1 control unit, using the Master/Slave principle. The control board is preinstalled in the door air curtain unit and 20 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

10

Page 11: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

CIRCUIT DIAGRAM FOR ELECTRICAL HEAT EXCHANGER

ZEPHYR E EC

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

230V/ 50Hz

3

CONTROL

F 16 AT

L N PE

Platine EC

Anschlußbox

bauseitig

Erdung, Nullung oderSchutzschaltung nachden Vorschriften desVDE und des zuständ.EVU ausführen.

Technische Änderungen vorbehalten

Störun

g pot.

-frei

Betrie

b pot.

-frei

1 211 12 133 4 514 15

0

zum Steuerteil (CONTROL)Adresse 1-9

8

AUXILIARNL2 PE

230V / 50Hz

Magnetventil(OPTIONAL)

L PEN

8

PENL2

internAUX MON

07.03.2017lagezeichnet/signet

TeileGruppevonPos.

Werkstoff Maßstab

Blatt

Erstelldatum

GTM EC MOD Bus 170307Kunde

BenennungName

Kundenzeichnung Nr.:

DatumName

1 von 1

6 716 17 8 9 10 1918 20

CPU

AdressSchalter0 = MASTER1 - 9 = SLAVE

5

1 23

4

9

87 6

nicht

beleg

t

nicht

beleg

t

nicht

beleg

t

nicht

beleg

t

Fros

tschu

tzthe

rmos

tatop

tiona

l

Standard Anschlusskabel(20 m) mitRJ-45 Stecker

1M

PENL1

zu weiterenVentilatoren

blau/blue

gelb/yellow

weiss/white

rot/red

4

321

RJ 45

MOD Bus 1 2 3 4

ON

optio

nal

ext. S

ignalg

eber

DDC-

Fre

igab

e op

tiona

l

Y PWM

0 V

+10 V

imp.

ModBusinterface(optional)

GTM I PTC ECCircuit diagram for 400V PTC heating elements (only for M Series)

Blow

out T

emp s

enso

r

CONTROL

PCB EC

Technical changes reserved

1 211 12 133 4 514 15

0

to inputCONTROLnext PCB

8

AUXILIAR

8

AUX MON

02.01.2019Sagezeichnet/signet

TeileGruppevonPos.

Werkstoff Maßstab

Blatt

Erstelldatum

GTC E EC UK 190201Kunde

BenennungName

Kundenzeichnung Nr.:

DatumName

1 von 1

6 716 17 8 9 10 1918 20

CPU

Adressswitch0 = MASTER1 - 9 = SLAVE

5

1 23

4

9

87 6

Failu

re

Oper

ation

free

Standard supplied shielded datacable (20 m)1:1 straight wired RJ-45 Stecker

S 50°K1

K1 K2 K3

S 80°

S 60°

q q

q

q

K1

Connecting box

Mains switch and fusesto be installed by thirdparties must complyto all applicable rules andrequirements!

BMS

On/O

ff

1M

PENL1

nextFan

blau/blue

gelb/yellow

weiss/white

rot/red

optio

nal

4

free

step 2step 3 = step 1 + step 2

step 1

NL2 PE

PENL2intern

230V / 50Hz

K3 K2

230V/ 50Hz

3

3~400V/ 50Hz4

K0

q

ext.

Sign

alop

tiona

l

Fros

t the

rmos

tat

optio

nal

Room

Tem

p se

nsor

q q

Room temperature. Sensor installed

S 45°

YPWM

0 V

+10 V

imp.

L N PE31 2

S 100°

F 16 AT

Timeroff

Fr 21.09.201807:52

Heat level0 / 0

AutomaticHand

Room Temp10°C

Fan level0 / 0

CONTROL UNIT GTC E EC Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. 5-stage fan operation or stageless fan control – easy to adjust on the control unit using the touch display. The electric heater can be activated in 3 stages.The relevant operating modes and symbols are arranged clearly on the colour display. The date, time and room temperature are shown as standard. The room temperature is monitored via an internal temperature sensor in the control unit as standard. An easy-to-navigate menu offers a selection of different operating modes: Hand – manual operation Auto AS – automatic operation via cool down protection Auto RT – automatic operation via room temperature Auto TK – automatic operation via door contact Auto AT – automatic operation via constant discharge temperature Auto Kombi – option to combine all individual automatic modes An enabling contact and potential-free operation and malfunction signals are provided for control via an on-site BMS or BEMS. A constant discharge temperature can be set via an optional cable temperaturesensor. This enables optimisation of the shielding performance. A week timer is incorporated as standard, enabling up to 12 different switching times to be programmed per week. Errors and faults are displayed with a red „warning“ sign. By coding the control boards differently, up to 10 door air curtains can also be operated in parallel with 1 control unit, using the Master/Slave principle.The control board is preinstalled in the door air curtain unit and 20 m of preassembled data cable (connection between the door air curtain and control unit) are included as standard. 11

Page 12: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

12

OPTIONAL ACCESSORIESZEPHYR EC

Thermostatic straight-way valve

(Setting range + 20 °C to + 35 °C) limits the discharge temperature (constant supply air temperature limitation). Also available as a 3-way valve.

Solenoid valve

Opens or closes the warm water circuit in the summer/winter setting of the control unit, in order to close the heating water circuit and save energy during summer operation or when the air curtain is not working (normally closed). Caution: If solenoid valves are used, it is expressly recommend-ed to install a frost protection thermostat (automatically actuat-ed) and a strainer.

Thermo-electric shut-off valve

230 V / 50 Hz, normally closed.On-site installation in theheating flow. Actuated bythe summer/ winter circuit. Summer function – closed. Winter function – opened.

Ceiling attachment set

For problem-free, vibration free ceiling attachment, consisting of M8 or M10 threaded rods, up to 1000 mm length, vibration dampers, turnbuckles and coun-ter nuts.

Page 13: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

13

Frost protectionthermostat

For monitoring LPHW heat exchangers exposed to the risk of frost. As soon as the temper-ature falls below +7 °C, the fans are switched off and an optional solenoid valve is opened.

Control unitGTC 2 EC

Possibility of combination of various automatic operations. A constant discharge tempera-ture can be set via an optional electronic control valve, and a week timer is incorporated as standard, enabling up to 12 different switching times to be programmed per week.

Electronic control valve

Electronic valve with 0-10V im-pulse and blow-out temperature sensor completely installed and wired. In combi-nation with the GTC 2 control, a preselected blow-out tempera-ture is kept constant.

Door contact solenoid switch

In automatic mode switches on the door air curtain in the preselected stage

Page 14: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

TECHNICAL DATAFREE HANGING / CASSETTE SUS-PENDED CEILING

ZEPHYR EC M

Model M 1 M 1.5 M 2 M 2.5 M 3

Air quantity max: m3/h 1800 2700 3600 4500 6300

Heating capacity rated1 LPHW 70 / 50 °C kW 8.5 12.7 17.0 21.2 29.7

LPHW 60 / 40 °C kW 8.5 12.7 17.0 21.2 29.7

Flow rate LPHW 70 / 50 °C m3/h 0.37 0.56 0.75 0.93 1.30

LPHW 60 / 40 °C m3/h 0.37 0.55 0.74 0.92 1.29

Water resistance LPHW 70 / 50 °C kPa 0.5 5.7 2.4 3.2 5.6

LPHW 60 / 40 °C kPa 3.8 7.0 4.5 3.2 5.6

Nominal connection sizes Internal thread Inches 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4"

Flow/return DN 20 20 20 20 20

EC fans Voltage V 230 / 1 / N / PE

Frequency Hz 50

Max. current consump-tion

A 2.1 3.1 4.1 5.1 7.2

Max. motor power kW 0.3 0.5 0.6 0.8 0.9

400 V PTC Electric heater Voltage V 400 / 3 / N / PE

Frequency Hz 50

Heating capacity kW 7 10,5 14 17,5 on request

Sound pressure level 2 Highest setting dB (A) 58 59 60 61 62

Drawing dimension Unit length ( A ) mm 1000 1500 2000 2500 3000

Unit height 3 mm 260 260 260 260 260

Unit depth 4 mm 490 490 490 490 490

Weight Zephyr kg 45 60 75 80 100

Cassette kg 52 70 88 97 120

Zephyr-Z kg 62 85 107 122 149

Design based on: recommended operating pointIntake temperature tLE = +20 °C

Discharge temperature tLA = +34 °CDischarge height = up to 2.70 m

1. Rated operation based on operating point (see above), discharge temperature control recommended.2. measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions.3. For the Zephyr Z (suspended ceiling version), this dimension changes to 390–470 mm.4. For the Zephyr Z this dimension changes to 720 mm and to 700 mm for the cassette (ceiling-flush version).

A well-balanced pressure ratio is one of the prerequisites for perfect function.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

14

Page 15: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

TECHNICAL DATAFREE HANGING / SUSPENDED CEILING

ZEPHYR EC L

Model L 1 L 1.5 L 2 L 2.5 L 3

Air quantity max: m3/h 2700 3600 5400 6300 7200

Heating capacity rated1

LPHW 70 / 50 °C kW 12.7 17.0 25.5 29.7 34.0

LPHW 60 / 40 °C kW 12.7 17.0 25.5 29.7 34.0

Flow rate LPHW 70 / 50 °C m3/h 0.56 0.75 1.11 1.31 1.49

LPHW 60 / 40 °C m3/h 0.55 0.74 1.11 1.29 1.48

Water resistance LPHW 70 / 50 °C kPa 0.8 2.8 3.7 5.2 7.2

LPHW 60 / 40 °C kPa 1.7 3.7 4.2 6.1 7.2

Nominal connection sizes

Internal thread Inches 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4" 2 x 3/4"

Flow/return DN 20 20 20 20 20

EC fans Voltage V 230 / 1 / N / PE

Frequency Hz 50

Max. current consump-tion

A 3.1 4.1 6.2 7.2 8.2

Max. motor power kW 0.5 0.6 0.9 1.1 1.2

Electric heater3-stage

Voltage V 400 / 3 / N / PE

Frequency Hz 50

Heating capacity kW 5//10/15 7,5/15/22,5 10/20/30 10,7/21,4/32 10,7/21,4/32

Sound pressure level 2 Highest setting dB (A) 60 61 62 63 64

Drawing dimension Unit length ( A ) mm 1000 1500 2000 2500 3000

Unit height 3 mm 260 260 260 260 260

Unit depth 4 mm 490 490 490 490 490

Weight Zephyr kg 50 65 80 105 125

Cassette kg 57 75 93 122 145

Zephyr-Z kg 67 90 112 147 174

Design based on: recommended operating pointIntake temperature tLE = +20 °C

Discharge temperature tLA = +34 °CDischarge height = up to 3.00 m

1. Rated operation based on operating point (see above), discharge temperature control recommended.2. measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions.3. For the Zephyr Z (suspended ceiling version), this dimension changes to 390–470 mm.4. For the Zephyr Z this dimension changes to 720 mm and to 700 mm for the cassette (ceiling-flush version).

A well-balanced pressure ratio is one of the prerequisites for perfect function.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

15

Page 16: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

TECHNICAL DATAFREE HANGING / SUSPENDED CEILING

ZEPHYR EC LX

Model LX 1 LX 1.5 LX 2 LX 2.5 LX 3

Air quantity max: m3/h 4500 5100 7300 9800 12000

Heating capacity rated1

LPHW 70 / 50 °C kW 21.2 24.0 34.4 46.2 56.6

LPHW 60 / 40 °C kW 21.2 24.0 34.4 46.2 56.6

Flow rate LPHW 70 / 50 °C m3/h 0.93 1.05 4.51 2.02 2.48

LPHW 60 / 40 °C m3/h 0.92 1.05 1.50 2.01 2.47

Water resistance LPHW 70 / 50 °C kPa 4.5 4.1 9.1 4.4 6.9

LPHW 60 / 40 °C kPa 3.2 4.1 3.7 4.5 7.0

Nominal connection sizes

Internal thread Inches 2 x 1“ 2 x 1" 2 x 1" 2 x 1" 2 x 1"

Flow/return DN 25 25 25 25 25

EC fans Voltage V 230 / 1 / N / PE

Frequency Hz 50

Max. current consump-tion

A 6.0 6.5 9.1 12.1 15.0

Max. motor power kW 1.1 1.4 2.1 2.7 3.5

Sound pressure level 2 Highest setting dB (A) 64 63 64 65 67

Drawing dimension Unit length ( A ) mm 1000 1500 2000 2500 3000

Unit height 3 mm 450 450 450 450 450

Unit depth 4 mm 715 715 715 715 715

Weight Zephyr kg 85 105 145 180 225

Cassette kg 97 123 168 213 260

Zephyr-Z kg 102 130 177 222 274

Design based on: recommended operating pointIntake temperature tLE = +20 °C

Discharge temperature tLA = +34 °CDischarge height = up to 3.20 m

1. Rated operation based on operating point (see above), discharge temperature control recommended.2. measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions.3. For the Zephyr Z-LX/LXX (suspended ceiling version), this dimension changes to 580-680 mm.4. For the Zephyr Z-LX/LXX this dimension changes to 1100 mm.

A well-balanced pressure ratio is one of the prerequisites for perfect function.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

16

Page 17: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

TECHNICAL DATAFREE HANGING / SUSPENDED CEILING

ZEPHYR EC LXX

Model LXX 1 LXX 1.5 LXX 2 LXX 2.5 LXX 3

Air quantity max: m3/h 4900 7300 9800 12000 14200

Heating capacity rated1

LPHW 70 / 50 °C kW 23.1 34.4 46.2 56.6 67.0

LPHW 60 / 40 °C kW 23.1 34.4 46.2 56.6 67.0

Flow rate LPHW 70 / 50 °C m3/h 1.01 1.51 2.02 4.48 2.93

LPHW 60 / 40 °C m3/h 1.01 1.50 2.01 4.45 2.92

Water resistance LPHW 70 / 50 °C kPa 1.3 2.9 7.9 7.8 9.6

LPHW 60 / 40 °C kPa 3.8 2.4 4.7 7.8 9.7

Nominal connection sizes

Internal thread Inches 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4" 2 x 1 1/4“ 2 x 1 1/4"

Flow/return DN 32 32 32 32 32

EC fans Voltage V 230 / 1 / N / PE

Frequency Hz 50

Max. current consump-tion

A 6.1 9.1 12.1 15.2 18.2

Max. motor power kW 1.4 2.1 2.8 3.5 4.1

Sound pressure level 2 Highest setting dB (A) 63 64 65 66 68

Drawing dimension Unit length ( A ) mm 1000 1500 2000 2500 3000

Unit height 3 mm 450 450 450 450 450

Unit depth 4 mm 715 715 715 715 715

Weight Zephyr kg 100 130 180 210 250

Cassette kg 112 148 203 238 285

Zephyr-Z kg 117 155 212 252 299

Design based on: recommended operating pointIntake temperature tLE = +20 °C

Discharge temperature tLA = +34 °CDischarge height = up to 3.60 m

1. Rated operation based on operating point (see above), discharge temperature control recommended.2. measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions.3. For the Zephyr Z-LX/LXX (suspended ceiling version), this dimension changes to 580-680 mm.4. For the Zephyr Z-LX/LXX this dimension changes to 1100 mm.

A well-balanced pressure ratio is one of the prerequisites for perfect function.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

17

Page 18: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

Model DX-M 1 DX-M 1.5 DX-M 2 DX-M 2.5 DX-M 3

Air quantity max: m3/h 1800 2700 3600 4500 6300

Power 1 DX heating capacity kW 8.6 12.9 17.3 21.3 29.9

DX cooling capacity kW 8.1 12.5 16.9 21.3 29.9

Delivery and intake line Connections mm 10/16 10/16 10/18 10/22 10/22

EC fans 3 Voltage V 230 / 1 / N / PE

Frequency Hz 50

Max. current consump-tion

A 2.4 3.6 4.7 5.9 8.2

Max. motor power kW 0.3 0.5 0.7 0.8 1.2

Sound pressure level 2 Highest setting dB (A) 58 59 60 61 62

Drawing dimension Unit length ( A ) mm 1210 1710 2210 2710 3210

Unit height mm 260 260 260 260 260

Unit depth mm 490 490 490 490 490

Weight Zephyr DX kg 50 65 80 85 105

Cassette kg 57 75 93 102 125

Zephyr Z kg 67 92 112 127 154

ZEPHYR-DX M EC

Design based on:

recommended operating pointintake temperature = +20/27 °Cdischarge temperature = +34/18 °Cdischarge height = up to 2.70 m

heating gas temperature = 70 °Ccondensation temperature = 50 °Ccondensate exit temp. = 45 °Coperating pressure = max. 45bar

TECHNICAL DATAFREE HANGING/CASSETTE / SUSPENDED CEILING

1. Rated operation based on operating point (see above).2. measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions.3. Control voltage 0-10 V.4. Only heating modus possible.

WARNING: in cooling mode the discharge temperature must not fall below 18 °C and the intake temperature must not rise above 27 °C! If these parameters are not adhered to, a higher level of condensate will form which cannot be re-moved by our optional condensate pump!

A well-balanced pressure ratio is one of the prerequisites for perfect function.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

460

260

105

460

260

105

BOTTOM VIEW SIDE VIEW

rivetting nut M8

space for control (on site)

cable penetration

18

Page 19: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

TECHNICAL DATAFREE HANGING/CASSETTE / SUSPENDED CEILING

ZEPHYR-DX L EC

Model DX-L 1 DX-L 1.5 DX-L 2 DX-L 2.5 DX-L 3

Air quantity max: m3/h 2700 3600 5400 6300 7200

Power 1 DX heating capacity kW 12.7 17.0 25.7 29.6 34

DX cooling capacity kW 12 16.6 25.2 29.7 34.2

Delivery and intake line Connections mm 10/16 10/18 10/22 10/22 10/22

EC fans 3 Voltage V 230 / 1 / N / PE

Frequency Hz 50

Max. current consump-tion

A 3.5 4.7 7.1 8.2 9.4

Max. motor power kW 0.5 0.7 1.0 1.2 1.4

Sound pressure level 2 Highest setting dB (A) 60 61 62 63 64

Drawing dimension Unit length ( A ) mm 1210 1710 2210 2710 3,210

Unit height mm 260 260 260 260 260

Unit depth mm 490 490 490 490 490

Weight Zephyr DX kg 55 65 85 110 130

Cassette kg 62 80 98 127 150

Zephyr Z kg 72 95 117 152 179

Design based on:

recommended operating pointintake temperature = +20/27 °Cdischarge temperature = +34/18 °Cdischarge height = up to 3.00 m

heating gas temperature = 70 °Ccondensation temperature = 50 °Ccondensate exit temp. = 45 °Coperating pressure = max. 45bar

1. Rated operation based on operating point (see above).2. measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions.3. Control voltage 0-10 V.4. Only heating modus possible.

WARNING: in cooling mode the discharge temperature must not fall below 18 °C and the intake temperature must not rise above 27 °C! If these parameters are not adhered to, a higher level of condensate will form which cannot be re-moved by our optional condensate pump!

A well-balanced pressure ratio is one of the prerequisites for perfect function.

* WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES

19

Page 20: ZEPHYR - TEKADOOR€¦ · Multilingual, menu-driven electronic control unit for TEKADOOR air curtains with LPHW heating and energy-saving EC fans. A standard feature of the control

German headquartersTEKADOOR GmbH Albert-Einstein-Str. 11 D-40764 Langenfeld

T. +49 (0) 2173 - 20766-0F. +49 (0) 2173 - 20766-111E. [email protected]

www.TEKADOOR.de

A = 01.07.2019